DOMESTIC / FRIDGE & LIGHT COMERCIAL COMPRESSOR SELECTION CHART

DOMESTIC SINGLE DOOR FRIDGE


Inside Compressor R 22 Gass R 410 A Remarks
Volume size
R 134 A
(Being Gass
Length x
Phased Out )
Width x
Depth
113 to 160 1/10 Hp compressor is about 2% bigger than a 1/12 Hp
Liter
1/12 H.P.       compressor - It may be used with CAUTION
Be very Clearful of  12V DC Compressor installations
( Sucess rates are low )
170 to198
Liter
1/10 H.P.    

226 to 254
1/8 H.P.    
 
Liter

283 to 370
Liter
1/6 H.P.      
DOMESTIC DOUBLE DOOR FRIDGE  
If there is any doubt of compressor size, ALLWAYS go one
226 to 340 size SMALLER
Liter
1/5 H.P.     NEVER go to a BIGGER Compressor

Allways pull a DEEP VACUUM on your System

370 to 481
Liter
1/4 H.P.    

Never install a compressor on a Blocked / Dirty or


509 to 623 Contaminiated / WET (Water) System
Liter
1/3 H.P.    

UPRIGHT AND CHEST FREEZER  


Allways Replace the Drier
113 to 120 Contaminated systems must have a bigger Drier after
Liter
1/6 H.P.     Cleaning

 
198 to 226
Liter
1/5 H.P.    

 
254 to 340
Liter
1/4 H.P.    

3/8 Hp compressor is about 4% bigger than a 1/3 Hp


370 to 509 compressor - It may be used with CAUTION
Liter
1/3 H.P.    
538 to 623
Liter
3/8 H.P.        
UNDERCOUNTER FRIDGE  
NEVER put the WRONG gass in the SYSTEM or
1 Door 1/4 H.P.   COMPRESSOR

Never install a compressor on a Blocked / Dirty or


Contaminiated / WET (Water) System
2 Door 1/3 H.P.  
ALLWAYS Replace the Drier
ALLWAYS instal Burnout Drier After Any Compressor
BURNOUT
3 Door 3/8 H.P. Failure to install Burnout Driers Will Cause another
  Burnout very soon afterward

ALLWAYS Match your Expansion Value orrifce to the


Compressor / System
Wrong Orifice Cause POOR Refrigeration and wrong
4 Door 1/2 H.P. Superheat that will cuase Compressor to Fail

 
 
5 Door 3/4 H.P.  

6 Door 1 H.P.        
COKE FRIDGES  
 
1 Door 3/8 H.P.    

 
2 Door 1/2 H.P.    

 
3 Door 3/4 H.P.    