Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Battery system scheme for pure electric vehicle

Sheet metal
stretch box Explosion
cover proof valve

◼ Lightweight design, high-pressure die-


casting aluminum alloy box;
◼ Liquid cooling cycle design, built-in water-
Modular cooling plate, further improving thermal
LECU plate
reactor conductivity and wider temperature
application range ;
◼ System energy density >140Wh/kg;
◼ New sealing structure design, protection
Low voltage level :IP68;
LECU maintenance
plug-in ◼ Safety design : Built in silicone oil /
window
External location MSD, Double
protection ;

High pressure Water MSD High voltage


T-ring
casting box pipe joint (Optional fuse) plug-in

© Microvast, Inc. Proprietary Confidential V2018Q1 www.microvast.com Page - 1


Basic parameters of battery pack

MV-B PACK MV-C PACK

Cell Quantity 72*4=288 pcs 72*6=432 pcs

Capacity Max:22.4kwh Max:33.6kwh

Dimension 820*660*240 1060*660*240

Energy Density ≥140wh/kg ≥140wh/kg

Continuous Charge/Discharge 250A 250A

Protection Level IP68 IP68

Legend

© Microvast, Inc. Proprietary Confidential V2018Q1 www.microvast.com Page - 2


Recommended battery pack scheme
MV-B PACK MV-C PACK

Series/Parallel Connection 4P72S 6P48S 6P72S 8P54S

Nominal Voltage 266.4V 177.6V 266.4V 199.8V

Nominal Capacity 84Ah 126Ah 126Ah 168Ah

Nominal Energy 22.4kWh 22.4kWh 33.6kWh 33.6kWh

Operating Voltage Range 194V~310V 130V~206V 194V~310V 146V~232V

MV-B PACK MV-C PACK System Power System Energy Remarks

2B4 0 532.8V/84Ah 44.8kWh Single loop

0 2C6 532.8V/126Ah 67.1kWh Single loop

4B4 0 532.8V/168Ah 89.5kWh Double loop

0 4C6 532.8V/252Ah 134.3kWh Double loop

4B6 2C6 621.6V/252Ah 156.6kWh Double loop

2B8 4C8 532.8V/336Ah 179Kwh Double loop

0 6C6 532.8V/378Ah 201.4kWh Three loop

© Microvast, Inc. Proprietary Confidential V2018Q1 www.microvast.com Page - 3


Vehicle configuration scheme

6.5m vehicle pure electric scheme 8.5m vehicle pure electric scheme 10-12m vehicle pure electric scheme
◼ Energy:44.8kWh ◼ Energy :89.5kWh ◼ Energy :134.3kWh
◼ Specification:144S4P(2Bpack) ◼ Specification :144S8P(4Bpack) ◼ Specification :144S12P(4Cpack)
◼ Nominal Voltage/Capacity:532.8V/84Ah ◼ Nominal Voltage/Capacity :532.8V/168Ah ◼ Nominal Voltage/Capacity :532.8V/252Ah
◼ Operating Voltage Range:390V~619V ◼ Operating Voltage Range :390V~619V ◼ Operating Voltage Range :390V~619V
◼ Continuous Charge Current:2C ◼ Continuous Charge Current :2C ◼ Continuous Charge Current :2C
◼ Operation Platform:Microcirculation ◼ Operation Platform : City Bus,Intercity ◼ Operation Platform : City Bus,Intercity
bus,Subway connecting bus. bus bus

Quick Charging:2C charge current;


Efficient operation and flexible scheduling : It can be charged 2-3 times a day, with driving mileage of 80-120km for
one charge, covering public transport routes within 120km for one-way operation and 150-300km for one-day
operation.
© Microvast, Inc. Proprietary Confidential V2018Q1 www.microvast.com Page - 4