This document is a gas cutting set inspection checklist for Bhabhua Grinding Unit in Bihar, India. It contains 17 check points to ensure the safe use and storage of oxygen and acetylene cylinders, regulators, hoses, torches, and other gas cutting equipment. The inspection verifies that cylinders are upright and secured, equipment is in working order, hoses are protected from damage, and fire safety precautions like extinguishers are available. Upon completion, the inspection is signed off by the contractor, HSE officer, area representative, and user head.
This document is a gas cutting set inspection checklist for Bhabhua Grinding Unit in Bihar, India. It contains 17 check points to ensure the safe use and storage of oxygen and acetylene cylinders, regulators, hoses, torches, and other gas cutting equipment. The inspection verifies that cylinders are upright and secured, equipment is in working order, hoses are protected from damage, and fire safety precautions like extinguishers are available. Upon completion, the inspection is signed off by the contractor, HSE officer, area representative, and user head.
This document is a gas cutting set inspection checklist for Bhabhua Grinding Unit in Bihar, India. It contains 17 check points to ensure the safe use and storage of oxygen and acetylene cylinders, regulators, hoses, torches, and other gas cutting equipment. The inspection verifies that cylinders are upright and secured, equipment is in working order, hoses are protected from damage, and fire safety precautions like extinguishers are available. Upon completion, the inspection is signed off by the contractor, HSE officer, area representative, and user head.
Gas Cutting Set Inspection Checklist Contractor: Date of Inspection: BGU/HSE/CL 01 Location: Floor / Level: Gas Cutter: Frequency: Monthly Sr. Check Points Y/N/NA Remarks 01 Cylinders used are in upright and secured position. 02 Cylinders in use are kept away from sunlight sparks, and excessive heat. 03 Oxygen and acetylene cylinders are kept safe apart. 04 Cylinders are "Soap solution" tested for leakage. 05 Cylinders are kept away from live electrical cables or ground wires. 06 Cylinders used in the open are provided with shelter. 07 Condition of Regulators / Hoses / Torches / Pressure Gauge. 08 Regulators and torches are in working condition. 09 Hoses are free from tape or wrapping materials used for plugging leaks. 10 Proper connections used for fastening 11 Any kinked or tangled hoses. 12 Hoses protected from mechanical damage or burning. 13 Cutting torches hanging over cylinder. 14 Flash - back arrestor provided for cylinder. 15 Gas cutting Lighter available. 16 Fire extinguisher (ABC type). 17 Area housekeeping provided. Comments:
Checked By:
ECL HSE Officer: ECL Area Representative: ECL User Head