58' - 10"

14' - 10" 3' - 11" 5' - 1" 5' - 8" 13' - 3"
2' - 8"
3' - 3" 10' - 3" VICINITY MAP

WEST PARK BLVD

4' - 3"
EXTERIOR WALL A B

8' - 5"
(EST. CONSTRUCTION: 6"  US Building Survey, LLC

9' - 0"
C
VACANT SPACE

1' - 4"
2' - 0"
CONCRETE W/ FURRING)
(UNIT A1040) 15954 Mur-Len, Suite 122

14' - 8"
006 WH2

4' - 9"
0
3 Olathe, KS | 66062

PRESTON ROAD
WH1
0 0 913.568.4488
3 3

5' - 8"
005

SH=3'‐8"
2' - 7"
004

8' - 11"
MOP SINK
BUILDING OWNER INFORMATION

2' - 10"
4' - 1"
NORTH

4' - 1"
7' - 7"
0

5' - 1"
LOW WALL; 3 DISCLAIMER:
4'‐8" (HGT) COOLER FREEZER THESE DOCUMENTS HAVE BEEN PREPARED FOR INFORMATION ONLY AND ARE NOT PROVIDED FOR CONSTRUCTION.  
ALL DIMENSIONS AND EXISTING CONDITIONS MUST BE FIELD VERIFIED PRIOR TO ANY CONSTRUCTION.

4' - 9"
FIELD MEASUREMENTS ARE RECORDED TO THE NEAREST 1/32" AS DOCUMENTED IN THE FINAL CAD (.DWG) 

2' - 1"
11"
PS 004 2" GAS DOCUMENT.  DIMENSIONS SHOWN ARE ROUNDED TO THE NEAREST 1" FOR CLARITY.
Phillips Edison & Company

5' - 9"

SH=3'‐8"

HOOD
PS GENERAL INFORMATION: 11501 Northlake Drive
Cincinnati, Ohio | 45249

15' - 6"
WATER FILTER /  NO. OF LEVELS: 1
PS COOLER 513.746.2550

HOOD
BACKFLOW

6' - 4"
SH=3'‐0"

2' - 10"
9' - 2"
1' - 10" 3' - 0" BUILDING HEIGHT: +/‐ 34'‐0"  (TOP OF PEAK)
1' - 11"
GYP BD SOFFIT; 7' - 10" 3' - 7" 3' - 8" 6' - 5"

1' - 0"

2' - 9"
10'‐10" (HGT) RESTROOM (ADA) COMPLIANCE: NON‐COMPLIANT
COPYRIGHT NOTICE
PS *REFER TO LOD SUPPLEMENT

80' - 7"
Use of this drawing for reference or example on another
project requires the services of properly licensed

4' - 1"
6x6 BOXED  STRUCTURAL SPOT ELEVATIONS BS  =  BOTTOM OF STRUCT. architects and engineers. Reproduction of this drawing
2" GAS for reuse on another project is not authorized and may
COLUMN PS

5' - 10"

3' - 10"
*REFER TO PLAN FOR LOCATIONS BD = BOTTOM OF DECKING be contrary to the law.

SH=3'‐8"
0
3 FIRE PROTECTION (SPRINKER): YES

8' - 1"
BS=18'‐10" 003 DEMISING PARTITION FIRE ALARM: NO

6' - 7"
BD=20'‐10" (EST. CONSTRUCTION: 6" STL  WATER HEATER (WH1): RINNAI ‐ INSTANT HOT (GAS)
STUD W/ 5/8" GYP BD EA SIDE) M/N: RUC98 | S/N: BA‐033840

11' - 11"
0
3 WATER HEATER (WH2): RINNAI ‐ INSTANT HOT (GAS)
LOW WALL;
M/N: RUC98 | S/N: BA‐033840

79' - 6"
4'‐8" (HGT)

6' - 0"
HS 002 2" FIRE RISER
GAS METER: 1" SERVICE (RTU)

1' - 11"
0
3
COUNTER;  PS PS

Plano Market Street


3' - 8"
3'‐6" (HGT)
20

11" 8" 1' - 6" 1' - 4"


5' - 9" 19' - 1" 5' - 11" 2' - 9" 5' - 7" 6' - 7" 5' - 1" 3' - 8"

15' - 7"
GAS METER ELECTRIC METER WATER HEATER  WATER HEATER
001 PLYWOOD SOFFIT;

18' - 10"
(WH1) (WH2)
9'‐0" (HGT)

1901-1941 Preston Road


3'

2' - 8"

Plano, TX | 75093
- 6" 18x8 BOXED  LEGEND

1' - 9"
COLUMN (TYP)
SH/HH=4'‐0" = SILL/HEAD HEIGHT = FIRE ALARM
30 1'
FA
   (PULL STATION)
PR - 5" 0
7' 6
- 7" = DOOR WIDTH/TYPE FS = FIRE STROBE
OH

ADJACENT TENANT
SH

3"
METAL CANOPY; =3

6' - 9"
'‐8
"
11'‐2" (HGT) = SPOT ELEVATION
7' = CEILING FAN
- 7"

13' - 9"
CF
SH
=3
3' = FIRE EXTINGUISHER
'‐8
" - FE = ROOF DRAIN
6"

6' - 9"
RD    (INTERNAL)
= STUB FOR PLUMBING
SH=3'‐8"

0
4" DIA STEEL  3
8' - 7"
COLUMN

24' - 0"
36" DIA CONCRETE  CANOPY (ABOVE)
COLUMN (TYP)
16' - 9"

METAL RAIL W/ WOOD 
SLATS; 4'‐0" (HGT)

GLA: 4,926 sf
PANEL A PANEL B PANEL C
3' - 10"

EXISTING ELECTRICAL SUMMARY 4' - 3" 16' - 0" 4' - 5" 17' - 5" 3' - 3" 3' - 0" 11' - 7" 4' - 1"

COMPONENT MANUFACTURE CATALOG NO. VOLTAGE AMPS PHASING CIRCUITS COMMENTS


4
EXISTING FLOOR PLAN RESTROOM (005) RESTROOM (006)
NORTH
1/8" = 1'-0"
PANEL A EATON 1C96649G02 208Y/120 225 3PH/4W 32 USED W/ MAIN SWITCH (200A) RESTROOM COMPLIANCE (PHOTOS) ISSUE DATE
STANDING SEAM ROOF PEAK 1
PANEL B EATON 1C96649G02 208Y/120 225 3PH/4W 36 USED W/ MAIN SWITCH (200A) +/‐ 34'‐0" NOT TO SCALE 02.02.18
CLAY TILE
6' - 0"

PANEL C EATON 1C96649G02 208Y/120 225 3PH/4W 42 USED W/ MAIN SWITCH (200A) EFIS 


REVISIONS

PARAPET
4' - 6"

+/‐ 27'‐0"
EXISTING FINISH/CONDITIONS SUMMARY (A1040)
ROOM FLR MAT'L FLR COND. BASE WALL MAT'L WALL COND. CLG MAT'L CLG HGT CLG COND. ADD'L COMMENTS
5' - 0"

001 CERAMIC TILE GOOD 6" WOOD GYP BD (PTD) GOOD ACT 14'‐0" GOOD


34' - 0"

002 CERAMIC TILE GOOD 6" CERAMIC TILE FRP (FULL HGT) GOOD ACT 10'‐0" GOOD


5' - 10"

003 CERAMIC TILE FAIR 6" CERAMIC TILE GYP BD (PTD) FAIR GYP BD (PTD) 10'‐0" FAIR


PROJECT NUMBER
004 CERAMIC TILE GOOD 6" CERAMIC TILE FRP (FULL HGT) GOOD ACT (WASHABLE) 10'‐0" GOOD
1' - 0"

005 CERAMIC TILE GOOD ‐‐ GYP BD (PTD) GOOD GYP BD (PTD) 8'‐6" GOOD 5'‐9" CERAMIC TILE WAINSCOT STOREFRONT 8011
006 CERAMIC TILE GOOD ‐‐ GYP BD (PTD) GOOD GYP BD (PTD) 8'‐6" GOOD 5'‐9" CERAMIC TILE WAINSCOT 12'‐0"
8"

Unit A1040
NOTE
5' - 10"
12' - 0"

01)  STOREFRONT:  ALUMINUM / GLASS (GOOD CONDITION)

Existing Plan
02/02/18 01:26:34 PM

CONDITION EVALUATION DEFINITION:
3' - 6"

(GOOD) ‐ AVERAGE/ABOVE AVERAGE CONDITION.  NO REMEDIAL WORK IS RECOMMENDED OR REQUIRED.
(FAIR) ‐ AVERAGE CONDITION.  SOME WORK IS RECOMMENDED TO RETURN TO GOOD CONDITION GRADE
(POOR) ‐ BELOW AVERAGE CONDITION.  SIGNIFICANT WORK SHOULD BE ANTIPATED TO RESTORE 0'‐0" SHEET NUMBER
EFIS  STOREFRONT STONE EFIS (COLUMNS) 

AS1
(ALUMINUM)
FRONT ELEVATION ELEVATION (PHOTO)
3 2
1/8" = 1'-0" NOT TO SCALE