Professional Documents
Culture Documents
Data Sheet For SINAMICS G120X: Rated Data General Tech. Specifications
Data Sheet For SINAMICS G120X: Rated Data General Tech. Specifications
Data Sheet For SINAMICS G120X: Rated Data General Tech. Specifications
MLFB-Ordering data
6SL3220-2YE50-0AF0
Figure similar
Number of phases 3 AC
Offset factor cos φ 0.99
Rated power (LO) 160.00 kW 250.00 hp Cooling Air cooling using an integrated fan
Rated current (LO) 302.00 A 302.00 A Cooling air requirement 0.210 m³/s (7.416 ft³/s)
Rated current (HO) 250.00 A 240.00 A Installation altitude 1000 m (3280.84 ft)
Pulse frequency 4 kHz Transport -40 ... 70 °C (-40 ... 158 °F)
Output frequency for vector control 0 ... 200 Hz Storage -25 ... 55 °C (-13 ... 131 °F)
Relative humidity
Output frequency for V/f control 0 ... 550 Hz
95 % At 40 °C (104 °F), condensation
Max. operation and icing not permissible
Overload capability
Technical data are subject to change! There may be discrepancies between calculated and rating plate values.
Page 1 of 3 Generated Tue May 26 15:27:11 CEST 2020
Data sheet for SINAMICS G120X
MLFB-Ordering data
6SL3220-2YE50-0AF0
Figure similar
Number 6
Communication
Switching level: 0→1 11 V
Communication PROFINET, EtherNet/IP
Switching level: 1→0 5V
Connections
Max. inrush current 15 mA
Signal cable
Fail-safe digital inputs
0.15 ... 1.50 mm²
Conductor cross-section
Number 1 (AWG 24 ... AWG 16)
1 motor temperature sensor input, sensors that can be connected: PTC, KTY
and Thermo-Click, accuracy ±5 °C
Technical data are subject to change! There may be discrepancies between calculated and rating plate values.
Page 2 of 3 Generated Tue May 26 15:27:11 CEST 2020
Data sheet for SINAMICS G120X
MLFB-Ordering data
6SL3220-2YE50-0AF0
Figure similar
Efficiency class IE2 UL, cUL, CE, C-Tick (RCM), EAC, KCC, SEMI
Compliance with standards
F47, REACH
Comparison with the reference converter (90% / -43.00 %
100%)
I CE marking
EMC Directive 2004/108/EC, Low-Voltage
Directive 2006/95/EC
2274.9 W (1.09 %) 2777.5 W (1.33 %) 3661.0 W (1.75 %)
100%
50% 90% f
The percentage values show the losses in relation to the rated apparent power of the converter.
The diagram shows the losses for the points (as per standard EN 50598) of the relative torque
generating current (I) over the relative motor stator frequency(f). The values are valid for the basic
version of the converter without options/components.
*converted values
Degree of protection IP55 / UL type 12 Transport -40 ... 70 °C (-40 ... 158 °F)
Technical data are subject to change! There may be discrepancies between calculated and rating plate values.
Page 3 of 3 Generated Tue May 26 15:27:11 CEST 2020