Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

EVERFINE HAAS-1200 Test Report 1 Of 1

Spectrum Test Report

Spectrum 1.0=20.097mW/nm
CIE1931 EVERFINE
1.2 x = 0.4316 y = 0.4158
CCT = 3185K
1.0

0.8

0.6

0.4

0.2

0.0
380 480 580 680 780
Wavelength(nm)

Color Parameters:
Chromaticity Coordinate:x=0.4316 y=0.4158/u'=0.2423 v'=0.5251
CCT=3185K(Duv=0.0054) Dominant WL:Ld =580.2nm Purity=54.4%
Ratio:R=23.0% G=74.3% B=2.7% Peak WL:Lp=637.9nm FWHM=183.0nm
Render Index:Ra=94.7 AvgR=92.0
R1 =95 R2 =94 R3 =92 R4 =97 R5 =93 R6 =91 R7 =99
R8 =96 R9 =86 R10=85 R11=96 R12=72 R13=94 R14=95 R15=94

Photo Parameters:
Flux = 998.2 lm Eff. : 98.36 lm/W Fe = 3.653 W

Electrical parameters:
V = 24.298 V I = 0.4177 A P = 10.15 W PF = 1.000
LEVEL:OUT WHITE:ANSI_3000K

Status: Integral T = 274 ms Ip = 54264 (83%)

Model:2216/240D/24V/WW Number:02159-1-3 YK64-2 2.8-2.9


Tester:DAMIN Date:2020-04-03 11:11:36
Temperature:25.3Deg Humidity:65.0%
Manufacturer:EVERFINE Remarks:IP65/1M 24R