Professional Documents
Culture Documents
Section A: Input Data
Section A: Input Data
Wt. of Tup Wt 34 kN
Wt. of Anvil ( CHOICE OF DATA ENTRY) Manually
Wa Enter the value in blue box kN
750
Wt of Anvil Wa 750
Attachment Of frame To Foundation
Wt. of Frame Wst 383.5 kN
Thickness of Timber Pad t 0.6 m
E for Timber Pad Ea 1300000 kN/m2
Velocity of Fall of Tup V1 6 m/s
Coefficient of Restitution K 0.25
SBC of Soil sp 350 kN/m2
Uniform Compression of Soil 38000 kN/m3
SBC of Timber 4640 kN/m2
Area of Anvil La Ba m
3.2 2.6
1) Mass of anvil
2)Mass Of TUP
Section B: Preliminary Dimensioning
A Provided 33.37 m2
Depth of Pit 1m
Mass of Tup 3.46585117 tonne
Depth of the foundation below Anvil is a function of mass of tup, and the depths are given in cl.: 4.4.2, page 8, IS 2974
-2,1980.
Minimum thickness of elastic pad to be provided under the Anvil rang from 0.6 m to 1.2 m
W f min 906.5 kN
Safe
Limiting Frequency
wa 2 235788.8 (rad/sec)2
ws 2 15639.2507878503 (rad/sec)2
w4 -330452.389534535 w2 4.85E+09 = 0
w1 2 315069.872410131 (rad/sec)2
w2 2 15382.5171244038 (rad/sec)2
II.: Amplitude
V 0.325255102040816 m/s
Amplitude of Anvil
Aa 0.192870570588161 mm
Safe in Amplitude
Amplitude of Foundation
Af 0.064850347737396 mm
Safe in Amplitude
Safe