Ca Relays: Features Typical Applications

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

CA

AUTOMOTIVE POWER
RELAYS — SMALL SIZE,
LIGHT WEIGHT
CA RELAYS
FEATURES TYPICAL
1. Small size and light weight APPLICATIONS
For space saving, the outside dimensions
1. Motorcycles and automobiles
of the main body are reduced to be 21.5
Motorcycle cell motors, car air
mm (length) × 14.4 mm (width) × 37 mm
conditioners, halogen lamps, etc.
(height) (.846 × .567 × 1.457 inch) and
the weight is also reduced to be approx. 2. Agricultural equipment
19 g .67 oz (direct coupling 1 Form A, 1 3. Battery equipped devices such as
Form B type) conveyance vehicles
2. Low operating power (1.4W) type is
available (1 Form A, 1 Form B)
3. Since the terminal arrangement
complies with JIS D5011 B4-M1,
commercial connectors are available
for these types of relays.
4. Superior inrush characteristics
Despite its small size, 120A (max. 0.1 s)
capacity has been achieved by using
contacts that are good at withstanding
RoHS Directive compatibility information inrush currents and because of an
ingenious contacting mechanism. (1 a
http://www.nais-e.com/
and 1b)

SPECIFICATIONS
Contact
Type 12 V DC 24 V DC
Arrangement 1 Form A 1 Form B 1 Form C 1 Form C
Initial contact resistance (Initial)
Typ. 3 mΩ
(By voltage drop 6 V DC 1A)
Contact material Ag alloy (Cadmium free)
Max. 0.3 V
After electrical life test,
Max. 0.3 V Max. 0.4 V Max. 0.4 V
by voltage drop
After electrical life test, After electrical life test, After electrical life test,
Contact voltage drop 12 V DC 20 A
by voltage drop by voltage drop by voltage drop
(1.4 W type),
12 V DC 20 A 12 V DC 20 A 24 V DC 10 A
12 V DC 30 A
(1.8 W type)
20 A 12 V DC
Nominal switching capacity (1.4 W type) 10 A 24 V DC
20 A 12 V DC
(resistive load) 30 A 12 V DC (ON: 2s, OFF: 2s)
(1.8 W type)
Max. switching voltage 16 V 15 V 30 V
120 A (1.4 W type)
Rating Max. switching current 120 A 100 A 50 A (Inrush current)
150 A (1.8 W type)
20 A continuous
(1.4 W type)
Max. carrying current 20 A continuous 20 A continuous 10 A continuous
30 A for 1 min
(1.8 W type)
Min. switching capacity#1 1 A 12 V DC 1 A 24 V DC
Nominal operating power 1.4 W / 1.8 W 1.8 W
Mechanical (at 120 cpm) 106 5×105
Expected 20 A 10 5

life (min. (1.4 W, 1.8 W type) (ON: 2s, OFF: 2s)


operations) Electrical 105 (ON 2s, OFF 2s) 105 (ON 2s, OFF 2s)
30 A 2×104
(1.8 W type) (ON: 3s, OFF: 15s)
#1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load.

All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.


CA
Characteristics (at 20°C 68°F)
Type 12 V DC 24 V DC
15 cpm 1.4 W type: at nominal load
Max. operating speed ( 1.8 W type: at 20 A ) 15 cpm (at nominal load)

Initial insulation resistance Min. 10 MΩ at 500 V DC


Initial breakdown Between open contacts 500 V rms for 1 min.
voltage*1 Between contacts and coil 500 V rms for 1 min.
Operate time*2 (at nominal voltage) Max. 10 ms at 20°C (initial) Max. 10 ms (initial)
Release time (without diode)*2
Max. 10 ms at 20°C (initial) Max. 10 ms (initial)
(at nominal voltage)
Functional*3 Min. 200 m/s2 {20 G} Min. 100 m/s2 {10 G} Min. 100 m/s2 {10 G}
Shock resistance
Destructive*4 Min. 1,000 m/s2 {100 G}
Rubber bracket A type: Min. 100 m/s2 {10 G}, 50 Hz to 500 Hz Min. 44.1 m/s2 {4.5 G},
Functional*5
Direct coupling type or Screw-mounting type: Min. 44.1 m/s2 {4.5 G}, 33Hz 33 Hz
Vibration resistance
Rubber bracket A type: Min. 100m/s2 {10 G}, 50 Hz to 500 Hz Min. 44.1 m/s2 {4.5 G},
Destructive*6
Direct coupling type or Screw-mounting type: Min. 44.1 m/s2 {4.5 G}, 33Hz 33 Hz
Conditions for operation, Ambient
–30°C to +80°C –22°F to +176°F
transport and storage*7 temp.
(Not freezing and condensing
low temperature) Humidity 5% R.H. to 85% R.H.
Water-proof standard Plastic sealed type: JIS DO203S2, Dust cover type: JIS DO203R2 JIS DO203S2
Rubber bracket A type: 23 g .81 oz
Mass Direct coupling type or Screw-mounting type: 31 g 1.09 oz
19 g .67 oz

Electrical life (min. operation)


Motor load Halogen lamp load
Nominal coil voltage, V DC
(operating frequency ON: 2 s, OFF: 2 s) (operating frequency ON: 1 s, OFF: 14 s)
1 Form A, 1 Form B 12 105, 20 A 12 V DC 105, 20 A 12 V DC
12 10 , 20 A 12 V DC
5 105, 20 A 12 V DC
1 Form C
24 10 , 10 A 24 V DC
5 105, 6 A 24 V DC
Remarks
*1 Detection current: 10 mA *5 Detection time: 10µs
*2 Excluding contact bounce time *6 Time of vibration for each direction; X, Y, direction: 2 hours, Z direction: 4 hours
*3 Half-wave pulse of sine wave: 11ms; detection time: 10µs *7 Refer to Conditions for operation, transport and storage mentioned in AMBIENT
*4 Half-wave pulse of sine wave: 6ms ENVIRONMENT .

ORDERING INFORMATION
CA

Contact Coil voltage Classification


arrangement Protective construction Nominal operating power Classification of types (DC) Mounting method by type
1a: 1 Form A Nil: Plastic sealed type Nil: Standard type (1.8 W) Nil: Standard type 12 V A: Rubber bracket A type Nil: 1 Form C
1b: 1 Form B F: Dust cover type S: Low operating power D: with diode inside 24 V A: (1 Form A, 1 Form B) 5: 1 Form A or
1 : 1 Form C type (1.4 W) R: with resistor inside (1 Form C only) N: Screw mounting type 1 Form B
(1 Form A, 1 Form B) C: Direct coupling type

Notes: 1. Type with resistor/diode inside are available as options. Please consult our sales office.
2. Standard packing: Carton: 20 pcs. Case: 200 pcs.

COIL DATA
1) Standard type
Nominal Nominal Usable
Nominal Pick-up voltage, Drop-out Coil resistance,
Contact Plastic sealed operating operating voltage
Mounting type Dust cover type voltage, V DC voltage, V DC Ω
arrangement type current, mA power, mW range, V
V DC (at 20°C 68°F) (at 20°C 68°F) (at 20°C 68°F)
(at 20°C 68°F) (at 20°C 68°F) DC
Rubber bracket A CA1a-12V-A-5 CA1aF-12V-A-5 12 Max. 8 Min. 0.6 to 6 150±10% 80±10% 1.8 10 to 16
1 Form A Screw-mounting CA1a-12V-N-5 CA1aF-12V-N-5 12 Max. 8 Min. 0.6 to 6 150±10% 80±10% 1.8 10 to 16
Direct coupling CA1a-12V-C-5 CA1aF-12V-C-5 12 Max. 8 Min. 0.6 to 6 150±10% 80±10% 1.8 10 to 16
Rubber bracket A CA1b-12V-A-5 CA1bF-12V-A-5 12 Max. 8 Min. 0.6 to 6 150±10% 80±10% 1.8 10 to 16
1 Form B Screw-mounting CA1b-12V-N-5 CA1bF-12V-N-5 12 Max. 8 Min. 0.6 to 6 150±10% 80±10% 1.8 10 to 16
Direct coupling CA1b-12V-C-5 CA1bF-12V-C-5 12 Max. 8 Min. 0.6 to 6 150±10% 80±10% 1.8 10 to 16
Screw-mounting CA1-DC12V-N – 12 Max. 8 Min. 0.6 150±10% 80±10% 1.8 10 to 15
Direct coupling CA1-DC12V-C – 12 Max. 8 Min. 0.6 150±10% 80±10% 1.8 10 to 15
1 Form C
Screw-mounting CA1-DC24V-N – 24 Max. 16 Min. 1.2 75±10% 320±10% 1.8 20 to 30
Direct coupling CA1-DC24V-C – 24 Max. 16 Min. 1.2 75±10% 320±10% 1.8 20 to 30

All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.


CA
2) Low operating power type
Nominal Nominal Usable
Nominal Pick-up voltage, Drop-out Coil resistance,
Contact Plastic sealed operating operating voltage
Mounting type Dust cover type voltage, V DC voltage, V DC Ω
arrangement type current, mA power, mW range, V
V DC (at 20°C 68°F) (at 20°C 68°F) (at 20°C 68°F)
(at 20°C 68°F) (at 20°C 68°F) DC
Rubber bracket A CA1aS-12V-A-5 CA1aFS-12V-A-5 12 Max. 8 Min. 0.6 to 6 120±10% 100±10% 1.4 10 to 16
1 Form A Screw-mounting CA1aS-12V-N-5 CA1aFS-12V-N-5 12 Max. 8 Min. 0.6 to 6 120±10% 100±10% 1.4 10 to 16
Direct coupling CA1aS-12V-C-5 CA1aFS-12V-C-5 12 Max. 8 Min. 0.6 to 6 120±10% 100±10% 1.4 10 to 16
Rubber bracket A CA1bS-12V-A-5 CA1bFS-12V-A-5 12 Max. 8 Min. 0.6 to 6 120±10% 100±10% 1.4 10 to 16
1 Form B Screw-mounting CA1bS-12V-N-5 CA1bFS-12V-N-5 12 Max. 8 Min. 0.6 to 6 120±10% 100±10% 1.4 10 to 16
Direct coupling CA1bS-12V-C-5 CA1bFS-12V-C-5 12 Max. 8 Min. 0.6 to 6 120±10% 100±10% 1.4 10 to 16
* Other pick-up voltage types are also available. Please contact us for details.

DIMENSIONS mm inch

1. 1 Form A/1 Form B


Rubber bracket A type 2.5 SCHEMATIC (Bottom View)
21.5 14.4 10 .098
.846 .567 .394
1 Form A 1 Form B
15
.591
37
1.457

Including diode type, including load type also available.

17.4
.685

19.5
.768
9 5.5
.354 .217 Including load Including diode
15.4 (1 Form A) (1 Form C)
.606
12.4
.488
1.5
.059 0.8
.031
2.4
6
.094 Dimension: General tolerance
2 17 .236 Max. 1mm .039 inch: ±0.1 ±.004
.079 .669
21.5 1 to 3mm .039 to .118 inch: ±0.2 ±.008
.846
Min. 3mm .118 inch: ±0.3 ±.012

2. 1 Form A/1 Form B


Screw-mounting type
6.5 +0.3
–0 dia. hole
R10 14.4 3 .118 SCHEMATIC (Bottom View)
14 .567
.256 +.012
–0 dia. .551 2 .079
1 Form A 1 Form B
17.5
.689
7
.276

Including diode type, including load type also available.


37
1.457

21.5 .846 17.4


.685
19.5 .768
Including load Including diode
9 5.5 (1 Form A) (1 Form C)
.354 .217
15.4
.606
12.4
.488
0.8
.031 2.4
Dimension: General tolerance
6 .236 .094 Max. 1mm .039 inch: ±0.1 ±.004
1 to 3mm .039 to .118 inch: ±0.2 ±.008
Min. 3mm .118 inch: ±0.3 ±.012

All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.


CA
3. 1 Form A/1 Form B mm inch
Direct coupling type 21.5 14.4
.846 .567 SCHEMATIC (Bottom View)

1 Form A 1 Form B

37
1.457

Including diode type, including load type also available.


17.4
.685
19.5 .768
9 5.5
.354 .217
15.4
.606
12.4
.488
Including load Including diode
0.8
6 .236 .031 2.4 (1 Form A) (1 Form C)
.094

Dimension: General tolerance


Max. 1mm .039 inch: ±0.1 ±.004
1 to 3mm .039 to .118 inch: ±0.2 ±.008
Min. 3mm .118 inch: ±0.3 ±.012

4. 1 Form C
Screw-mounting type 6.6 dia. hole 4 SCHEMATIC (Bottom View)
.260 dia. 14 R10 .157 2
.551 .079
1 Form C
20
12 .787
.472

59
28 2.323
1.102
Including diode type, including load type also available.
40
1.575

31.2 1.228 19.4


.764
28.4 1.118
23.4 Including load Including diode
.921 5.5 (1 Form C) (1 Form A)
.217
0.8
.031 11.4 12.2
.449 .480
2.4
.094
6
.236 9 9
Dimension: General tolerance
.354 .354 Max. 1mm .039 inch: ±0.1 ±.004
1 to 3mm .039 to .118 inch: ±0.2 ±.008
Min. 3mm .118 inch: ±0.3 ±.012

5. 1 Form C
Direct coupling type
SCHEMATIC (Bottom View)
28 1 Form C
1.102
40
1.575

31.2 1.228 19.4


.764 Including diode type, including load type also available.
28.4 1.118
23.4
.921 5.5
.217
0.8
.031 11.4 12.2
.449 .480
2.4 Including load Including diode
.094 (1 Form C) (1 Form A)
6
.236 9 9
.354 .354

Dimension: General tolerance


Max. 1mm .039 inch: ±0.1 ±.004
1 to 3mm .039 to .118 inch: ±0.2 ±.008
Min. 3mm .118 inch: ±0.3 ±.012

All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.


CA
REFERENCE DATA
1. Coil temperature rise 2. Max. switching capability (Resistive load, 3. Ambient temperature and operating
Samples: CA1aS-12V-N-5, 5pcs. initial) temperature range
Measured portion: Inside the coil
Contact carrying current: 20A
Ambient temperature: Room temperature, 85°C
185°F
(N.O. side Room temperature)
140 60 40
Room
temperature 35

Coil applied voltage, VDC


120

Switching voltage, VDC


50
Temperature rise, °C

30
100
85°C 40
25
185°F
80
30 20 Operation range
60
15
20
40
10
10
20 5
Pick-up voltage
0 (Cold start)
0 0
12 14 16 0 10 20 30 40 50 –40 –30 –20 0 20 40 60 8085 100 120
Coil applied voltage, V Switching current, A Ambient temperature, °C

4. Ambient temperature characteristics 5. Distribution of pick-up and drop-out voltage 6. Distribution of operate and release time
(Cold start) Quantity: 50pcs. Sample: CA1a-12V-N-5, 10pcs.
Samples: CA1bS-12V-N-5

11 60 25
Pick-up voltage
Pick-up and drop-out voltage, V

Operate and release time, ms


10
Drop-out voltage
9 Pick-up voltage 50
20
8
Frequency, n

40
7
Drop-out voltage 15
6
30
5
10 Operate time
4
20
3 Max.
5 X
2 10 Min.
Release time Max.
1 X
0 0 Min.
0
–30 20 80 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 0 6 8 10 12 14 16
Ambient temperature, °C Voltage, V Coil applied voltage, %V

7-(1). Electrical life test (Motor load)


Sample: CA1a-12V-C, 3pcs.
Load: Inrush current: 63A, steady current: 23A
Blower fan motor actual load (motor free)
Switching frequency: (ON:OFF = 2s:2s)
Ambient temperature: Room temperature

Load current waveform Change of pick-up and drop-out voltage Change of contact resistance
Load: Inrush current: 63A, steady current: 23A,

10A
500ms
10 10
Pick-up and drop-out voltage, V

9
Contact resistance, mΩ

8 8
7
Pick-up voltage
6 Max. 6
X
5 Min.
4 4 Max.
Drop-out voltage X
3 Max.
X Min.
2 Min. 2
1
0 0
0 10 20 0 10 20
No. of operations, × 104 No. of operations, × 104

All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.


CA
7-(2). Electrical life test (Lamp load)
Sample: CA1a-12V-C, 3pcs.
Load: 60Wx4, Inrush current: 110A, steady current: 20A
Halogen lamp actual load
Switching frequency: (ON:OFF = 1s:14s)
Ambient temperature: Room temperature

Load current waveform Change of pick-up and drop-out voltage Change of contact resistance
Load: Inrush current: 110A, steady current: 20A,

20A
200ms
10 10

Pick-up and drop-out voltage, V


9 9

Contact resistance, mΩ
8 8
7 7
6 Pick-up voltage Max. 6
X
5 Min. 5
4 4
3 Drop-out voltage 3
Max. Max.
2 X 2 X
Min. Min.
1 1
0 0
0 10 20 0 10 20
No. of operations, × 10 4
No. of operations, × 104

Cautions regarding the protection element


1. Part numbers without protection 2. Part numbers with diodes
elements These relays use a diode in the coil surge
1) 12 V models protection element. Therefore, the
When connecting a coil surge protection release time is slower and the working life
circuit to these relays, we recommend a might be shorter compared to part
Zener diode with a Zener voltage of 24 V numbers without protection elements and
or higher, or a resistor (680Ω to 1,000Ω). part numbers with resistors.
When a diode is connected to the coil in Be sure to use only after evaluating under
parallel, the release time will slow down actual load conditions.
and working life may shorten. Before use, 3. Part numbers with resistors
please check the circuit and verify that This part number employs a resistor in
the diode is not connected in parallel to the coil surge protection circuit; therefore,
the coil drive circuit. an external surge protection element is
2) 24 V models not required. In particular, when a diode
When connecting a coil surge protection is connected in parallel with a coil, the
circuit to these relays, we recommend a revert time becomes slower which could
Zener diode with a Zener voltage of 48 V adversely affect working life. Please
or higher, or a resistor (2,800Ω to check the circuit and make sure that a
4,700Ω). diode is not connected in parallel with the
When a diode is connected to the coil in coil drive circuit.
parallel, the release time will slow down
and working life may shorten. Before use,
please check the circuit and verify that
the diode is not connected in parallel to
the coil drive circuit.

For Cautions for Use, see Relay Technical Information.