Professional Documents
Culture Documents
Certificate of Compliance: Tai Pham
Certificate of Compliance: Tai Pham
Certificate of Compliance: Tai Pham
The products listed below are eligible to bear the CSA Mark shown
with adjacent indicators 'C' and 'US' for Canada and US or with adjacent
indicator 'US' for US only or without either indicator for Canada only.
Tai Pham
Issued by:
Tai Pham
PRODUCTS
CLASS - C421181 - MOTORS AND GENERATORS-Certified to US Standards
CLASS - C421101 - MOTORS AND GENERATORS
Part A:
Three Phase Squirrel Cage Induction Motors, W22 series, 1000 V max., to 750 Hp Max, 50, 60, 50/60 Hz,
continuous duty, Class B, F and H insulation, 60°C ambient; NEMA Frames 143T to 588/9T (IEC Frames 63 to
355); 2, 4, 6, 8, 10, 12, 14, 16 and 18 poles, may be two speed, SF 1.25 max. for up to 500hp SF 1.17 max. for
above 500hp, Enclosure TEFC, TEAO, TENV or TEBC.
Three Phase Squirrel Cage Induction Motors, W22 series, 1000 V max, 125 to 200Hp, 60 Hz, continuous duty,
Class F insulation, 40°C ambient, NEMA Frames 444/5T to 447/9T (IEC Frame 280); 4 poles, SF 1.30, Enclosure
TEFC.
Three Phase Squirrel Cage Induction Motors, W22 series, 1000 V max, 125 to 200Hp, 60 Hz, continuous duty,
Class F insulation, 46°C ambient, NEMA Frames 444/5T to 447/9T (IEC Frame 280); 4 poles, SF 1.20, Enclosure
TEFC.
Three Phase Squirrel Cage Induction Motors, W22 series, 1000 V max, 30Hp Max., 50, 60 Hz, continuous duty,
Class H insulation, 80°C ambient, NEMA Frame 254T to 326T (IEC Frame 160 to 200); 6 and 8 poles, SF 1.00,
Enclosure TEAO.
Single phase Squirrel Cage Induction Motors, W22 series, capacitor start and/or run, split-phase, random wound,
15hp max. at 60Hz or 12hp max. at 50Hz, 460V max, 80A maximum, SF 1.15 max, 2 to 8 poles, Class B, F or H
insulation, 50°C maximum ambient temperature, NEMA frames 143 to 215 (IEC frames 63 to 132), Enclosure
TEFC, or TEAO.
Three Phase Squirrel Cage Induction Motors, W22 series, 600 V max, 15Hp Max., 50, 60 Hz, continuous duty,
Class F and H insulation, 65°C ambient max, NEMA Frame 143T to 254T (IEC Frame 63 to 160); 2 to 8 poles,
SF 1.25 up 10Hp and SF 1.00 up to 15Hp, Enclosure TEFC.
Three Phase Squirrel Cage Induction Motors, W22 series, 600 V max, 3Hp Max., 50, 60 Hz, continuous duty,
Class F and H insulation, 40°C ambient max, NEMA Frame 143T to 215T (IEC Frame 63 to 132); 2 to 8 poles,
SF 1.33 max., Enclosure TEFC.
Three Phase Squirrel Cage Induction Motors, W22 series, 402 V max, 16Hp Max., 105 Hz, continuous duty,
Class F and H insulation, 77°C ambient max, NEMA Frame 143T to 215T (IEC Frame 63 to 132); 2 to 8 poles,
SF 1.00, Enclosure TEAO.
Three Phase Squirrel Cage Induction Motors, W22 series, 600 V max, 2Hp Max., 50, 60 Hz, continuous duty,
Class F and H insulation, 70°C ambient max, NEMA Frame 143T to 215T (IEC Frame 63 to 132); 2 to 8 poles,
SF 1.25, Enclosure TEFC.
Three Phase Squirrel Cage Induction Motors, W22 series, 600 V max, 15Hp Max., 50, 60 Hz, continuous duty,
Class F and H insulation, 71°C ambient max, NEMA Frame 143T to 284/6T (IEC Frame 63 to 180); 2 to 8 poles,
SF 1.25, Enclosure TEAO.
Three Phase Squirrel Cage Induction Motors, W22 series, 600 V max, 25Hp Max., 50, 60 Hz, continuous duty,
Class F and H insulation, 71°C ambient max, NEMA Frame 143T to 324/6T (IEC Frame 63 to 200); 2 to 8 poles,
SF 1.25, Enclosure TEAO.
Three Phase Squirrel Cage Induction Motors, W22 series, 600 V max, 10Hp Max., 50, 60 Hz, continuous duty,
Class H insulation, 68°C ambient max, NEMA Frame 143T to 286T (IEC Frame 63 to 180); 2 to 10 poles, SF
1.00, Enclosure TEFC.
Three Phase Squirrel Cage Induction Motors, W22 series, 600 V max, 5Hp Max., 50, 60 Hz, duty S6, Class H
insulation, 80°C ambient, NEMA Frame 143T to 254T (IEC Frame 63 to 160); 2 to 6 poles, SF 1.05, Enclosure
TEFC.
Note:
1. * in the model designation is replaced by letter and/or number representing frame materials.
2. TEAO motors are accepted as a component for use in other CSA Certified equipment where the suitability of
the combination is determined at the final application.
3. The motors covered under the scope above can be available as or with:
a. Two Speed Motors with the minimum number of poles 2, 4, 6, 8, 10, and 12.
b. Multiple Voltages.
c. Inverter and/or Vector Duty, max. SF 1,15.
d. Space Heater
e. Remote terminal box.
f. Additional junction box available for auxiliaries.
g. Aluminum frame and with removable feet.
h. May be fitted with brake.
4. Motors certified without a terminal box are accepted as components for use in other CSA Certified equipment
where the suitability of the combination is determined by CSA Group.
5. Model numbers may be followed by letters and/or numbers that signify mechanical variations that do not affect
the electrical design.
6. Motors are provided with optional temperature detectors inside to be connected in the end-use application.
7. When space heaters are used, they shall be energized only when the motor has been de-energized.
Energy Efficient motors (Models TE1B*0X0H, TE1B*0X0N, TE1B*0X0#, TE1B*0X0$, TE1B*0X0+, and
TE1B*0X1A)
Frame Size CT VT CHp Drive Comments
143 – 588/9 (IEC63 – 355) 12:1 1000:1 60 – 90 Hz (2 poles) any constant (V/f)
143 – 588/9(IEC63 – 355) 100:1 - 60 – 120 Hz (4 - 12 poles) WEG(*) optimized (V/f)
Premium Efficiency motors (Models TE1B*0X0N, TE1B*0X0#, TE1B*0X0$, TE1B*0X0+, and TE1B*0X1A)
Frame Size CT VT CHp Drive Comments
143 – 588/9 (IEC63 – 355) 20:1 1000:1 60 – 90 Hz (2 poles) any constant (V/f)
(*)
143 – 588/9 (IEC63 – 355) 1000:1 - 60 – 120 Hz (4 – 12 poles) WEG optimized (V/f)
NOTES:
1. (*) WEG drive (CFW) version 2.40 or higher
2. All frame sizes 143 up to 588/9 can also be blower cooled under request. In such case, the
motor will be suitable for variable and constant torque applications rated as Vector Duty up to
1000:1 with any type PWM drive.
444 – 447/9 (IEC280) 3 – 60 Hz (4 poles) 1000:1 60 – 120 Hz (4 poles) any constant (V/f)
324T/326T (IEC200) 23– 103 Hz (4 poles) 1000:1 60 – 120 Hz (4 poles) any constant (V/f)
Part B:
W22 Series, thermally protected, single phase, random wound squirrel cage induction motors, 1 to 12.5Hp,
240Vac max, 60Hz, 56.8A maximum, S.F. 1.15 max, 4 poles, Class F insulation, 40°C maximum ambient,
NEMA frame 143T to 215T (IEC frame 90S to 132M ). Enclosure Types TEFC, TEAO.
Notes:
1. Motors certified without a terminal box are accepted as components for use in other CSA Certified
equipment where the suitability of the combination is determined by CSA Group.
2. Model numbers may be followed by letters and/or numbers that signify mechanical variations that do not
affect the electrical design.
3. Motors are provided with optional temperature detectors inside to be connected in the end-use
application.
4. When space heaters are used, they shall be energized only when the motor has been de-energized.
APPLICABLE REQUIREMENTS
Part A:
CSA-C22.2 No 100-14 – Motors and Generators
UL 1004-1 (2nd Ed.) – Rotating Electrical Machines – General Requirements
UL 1004-8 (2nd Ed.) – Inverter Duty Motors
Part B:
CSA-C22.2 No 100-14 – Motors and Generators
UL 1004-1 (2nd Ed.) – Rotating Electrical Machines – General Requirements
CSA-C22.2 No 77-14 – Motors with Inherent Overheating Protection
UL 1004-3 (2nd Ed.) – Thermally Protected Motors