CONCRETE INITIAL SETTING TIME TEST

Contractor : PT. SHIMIZU CORPORATION


Project : DHARMA TOWER
Class of Concrete : FC30 NFA Slump retention 3 Hour
Slump : 16 ± 2 cm
Date : 07-Jan-19
PENETRATION
ELAPSE TIME SINCE
NO CHECK TIME BEARING TIME OF MIXING = 10 : 15 WIB
MIXING (hour)
(Lbf/inch²)

1 10 : 30 0 0,25 Keterangan :
2 13 : 30 0 3,25 - Initial setting time terjadi selama 10 : 09 Jam
3 14 : 30 0 4,25 Initial setting time terjadi jika jarum alat penetrasi
4 16 : 30 0 6,25 menunjukkan angka 500 ( lbf/inch² )
5 18 : 30 20 8,25 ASTM C 403
6 19 : 00 80 8,75 - Pada jam : 10 : 15 sampai jam : 16 : 30
7 19 : 15 130 9,00 pembacaan pada penetrometer masih menunjukkan
8 19 : 30 210 9,25 angka 0 ( Nol )
9 19 : 45 290 9,50
10 20 : 00 360 9,75
11 20 : 15 410 10,00

12 20 : 30 560 10,25

CURVE of PENETRATION BEARING vs TIME


700
BEARING SCALE (lbf/inch²)

600

500
PENETRATION

400
Penetration Bearing
300

200

100

0
0 1 2 3 4 5 6 7 8 9 10 11 12

ELAPSE TIME SINCE MIXING (hour)

Tested by : Eko Cahyono Date : 7 January 2019