UNIT-I

1. Define voltage regulation of a transformer. Deduce the expression for the voltage
regulation?
2. Write the step by step procedure to get equivalent circuit of transformer?
3. Explain in detail about the different types of losses that occur in transformers.
4. A single phase transformer working at unity power factor has an efficiency of 90% at
both half load and at full load of 500W. Determine the efficiency at 75% full load.
5. A 10kva, 1-phase transformer for 2000/400v at no load has R1=5.5 Ω, X1=12 Ω, R2=0.2
Ω, X2=0.45 Ω. Determine approximate value of secondary terminal voltage at full load
0.8 pf lagging. When the primary applied voltage is 2000v?

UNIT-II
1. With neat circuit diagram, explain how the efficiency can be predetermined by
conducting Sumpner’s test on transformers.
2. What are the necessary conditions for operating two transformers in parallel?

3. Derive an expression for saving of copper when an autotransformer is used?


4. A 1-Φ, 2400/240 V, 120 KVA two-winding transformer is connected as an Auto
transformer with additive and subtractive polarity. Determine the KVA rating of the Auto
Transformer in both the cases?
5. Obtain the approximate equivalent circuit of a 200 / 2000 V single-phase 30kVA
transformer referred to 200 V side using the following test results:
OC Test: 200 V 6.2 A 360 W on l.v. side
SC Test: 75 V 18 A 600 W on h.v. side

UNIT-III

1. Discuss the production of rotating magnetic field in induction motors.


2. Explain about Scott connection of transformers
3. Describe briefly the construction of a three phase connections of transformers
4. A 3-phase induction motor runs at 1440 rpm at full load when supplied power from 50
Hz, 3-phase line. Calculate: (i) The number of poles. (ii) Slip of full load. (iii) Speed of
the rotor field w.r.t rotor. (iv) Speed of the rotor field w.r.t stator.
5. A 3-phase induction motor is wound for 4 poles and is supplied from 50 HZ system.
calculate: i) The synchronous speed. ii) The rotor speed with slip is 4% and iii) Rotor
frequency when rotor runs at 600 RPM.

UNIT-IV

1. Derive an expression for full load torque in 3-Φ induction motor and obtain the relation
between full load torque and maximum torque.
2. Explain the no-load and blocked rotor tests on 3-phase induction motor
3. Explain about Torque-Slip characteristics of an induction motor
4. Derive the inter-relation between rotor input, rotor copper losses and mechanical power
developed in an induction motor
5. The stator loss of a three phase Induction motor is 2kW, when the power input is 90kW,
what will be the rotor mechanical power developed and the rotor copper loss if the motor
is running with a slip of 4%.

UNIT-V

1. With the help of circuit diagram and equations, explain Auto Transformer starting of
Induction motor.
2. Why induction motor require starting methods even though it is a self starting device
3. Explain the speed control of 3- phase induction motor using EMF injection method
4. Explain in detail about the working of rotor resistance starter with a suitable diagram?
5. Two 50 Hz, 3-Ф induction motor having 6 and 4-poles respectively are cumulatively
cascaded. The 6-pole motor being connected to the main supply. Determine frequencies
of rotor currents and the slips referred to each stator field. If the set has slip of 2%.