28'-0" [8400]

4'-0" 14'-0" [4200] 5'-0" 5'-0"


28'-0" [8400]
[1200] [1500] [1500]
4'-0" 19'-0" [5700] 5'-0"
Prop. soakway pit at
3'-0"Ø (900mm Ø)at 6'-0"
(1800mm) depth to detail
IC 1
L=5
.291
B [1200]
B
[1500]

m
W gt
4
6"up IC 2
LAUNDRY

[1200]
D 3"dn

4'-0"
2

9'-0" [2700]
4 1/2" thk. brkwall with 5/8"
10'-0" [3000]

LAUNDRY
thk plaster and painted
W F.F.L : 100.600 on both side
D

[1500]
5 KITCHEN 3"dn KITCHEN
4

5'-0"
4" Thk. Conc. Floor TH

19'-0" [5700]
BATH 3 1
Floor tiles finished
Cer. tiles BATH 3
9" wide precast drain conc. BEDROOM 4
laid to fall at gradient 1:200 DINING AREA

10'-0" [3000]
9'-0" [2700]

F.F.L : 100.600
F.F.L : 100.600

L=7
BEDROOM 4 W
W
4
DINING AREA 4" Thk. Conc. Floor 5
4" Thk. Conc. Floor Floor tiles finished

.485m
Floor tiles finished
D
3
3"dn
D
Pemilik :
FAMILY AREA

[1500]
4 TH

5'-0"
A 1
A A A
11'-0" [3300]

11'-0" [3300]
F.F.L : 100.600 BATH 2 D BATH 2
Cer. tiles 4
FAMILY AREA 3"dn
SD 4" Thk. Conc. Floor D
1 Floor tiles finished 3 IC 3 4 1/2" thk. brkwall with 5/8" thk.

10'-0" [3000]
F.F.L : 100.600 5'-0" high glazed wall tiles above
BEDROOM 3 W floor level all round internally
64'-0" [19200]

64'-0" [19200]

64'-0" [19200]

64'-0" [19200]
4" Thk. Conc. Floor 5
Floor tiles finished
BEDROOM 2 TENGKU ZAHARAH BINTI TENGKU MUSA
F.F.L : 100.600 NO.K/P : 630125-11-5052
[1800]
6'-0"
10'-0" [3000]

BEDROOM 2 BEDROOM 3

55'-0" [16500]
4" Thk. Conc. Floor NO. 108,
W Floor tiles finished
5 AIR TAWAR,
W
100mm Ø uPVC sewer pipe LIVING ROOM 22200 BESUT,
[1200]

1
4'-0" TERENGGANU.
4'-0"

D at gradient 1 : 80
3 [1200] W
1

25'-0" [7500]
17'-0" [5100]
F.F.L : 100.600
L = 9.000m
BATH 1 D D
LIVING ROOM BATH 1 Projek :
[1500]

TH 3"dn 3
4
5'-0"

1 Cer. tiles W
4" Thk. Conc. Floor
IC 6 Floor tiles finished
1
PERMOHONAN KELULUSAN PELAN BANGUNAN
W
1
BAGI CADANGAN MEMBINA DAN MENYIAPKAN
1 UNIT KEDIAMAN KEKAL 1 TINGKAT DI ATAS:
L=
10'-0" [3000]

F.F.L : 100.600 W
1
MASTER
5.3

D
BEDROOM 1
69m

4" Thk. Conc. Floor 6"up


[1200]

Floor tiles finished W W


4'-0"

1 1
MASTER BEDROOM
W W W LOT : PT 8056 (HSM 7072)
3 2 3
9'-0" [2700]

9'-0" [2700]

9'-0" [2700]
IC 4 TEMPAT : GONG NANGKA
m
IC 5 L = 8.825 MUKIM : KAMPUNG RAJA
PORCH PORCH
Homo. tiles finished DAERAH : BESUT
NEGERI : TERENGGANU
100mm upvc sewer pipe

1'-0" x 1'-0"" rc column to Arkitek :


Septic tank type ES 3 to detail

B
engineer's detail
B KHALID JOHARI ASSOCIATES
Prop. soakway pit at 2'-0" 12'-0" [3600] 14'-0" [4200] SDN. BHD
3'-0"Ø (900mm Ø)at 6'-0" [600]
(1800mm) depth to detail 28'-0" [8400]
ELECTRICAL LEGEND
2'-0" 7'-0" [2100] 5'-0" 14'-0" [4200]
6" Ø (150mmØ) vcp by-pass
[600] [1500] SYMBOL PARTICULAR
for future connection
28'-0" [8400] 25mmØ ventilation pipe

KHALID JOHARI ASSOCIATES SD. BHD. co.reg. no. BC/K 16


TNB meter box
DISCRIPTION FLOOR AREA
300 GLN. WATER STORAGE TANK 38mmØ g.i overflow pipe to toilet
COVERED AREA 1269 sq.ft (117.894 sq.m) COMPLETE WITH STOP COCK, 38mmØ anti syphonage pipe Distribution board
BALL VALVE, OVER FLOW AND
UNCOVERED AREA 226 sq.ft ( 20.996 sq.m) SCOUR PIPE AND COVER 38mmØ g.i distribution pipe
(class 'C')
Pendant fitting
TOTAL AREA 1495 sq.ft (138.890 sq.m)
38mmØ g.i scour valve pipe
discharge to toilet
BATH 1 BATH 2 BATH 3 LAUNDRY
Ceiling fan point
25mmØ g.i riser pipe (class 'C')

DP 10 PRS
roof level
water meter and stopcock
with ballafix valve
stopcock
KITCHEN sh

wc
sh

wc
sh

wc
one way switch
K A
Suite 10.01, Block B
sink tap besin tap besin tap besin tap two way switch Phileo Damansara 1
46350 Petaling Jaya
Selangor Darul Ehsan
Tel : 03 7665 1151
PVC TRUNKING 25mmØ g.i pipe class 'C' 13 amp. power point Fax : 03 7665 1150 AR. ABDUL KHALID JOHARI
A.P.A.M. LAM A/A 71
from JBA main pipe
PLUMBING NOTES TO PHONE floor level Aircondition

TO INCOMING EXISTING JC9C


DIAGRAMMATIC OF PLUMBING LAYOUT Fluorescent lamp with reflector
SDF (50) NOT TO SCALE
1. all plumbing works shall be carried out by plumber
registered with JBA/Water Works Department. ground level Tajuk Lukisan :
2. the registered plumber shall inform the
JBA/Water Work Department 7 days prior
FLOOR PLAN
to commencement of work on site. DIAGRAM OF TELEKOM LAYOUT ROOF PLAN
3. all concealed plumbing shall be
inspected and approved by the
Scale : 1/8" TO 1'0" ELECTRICAL LAYOUT
JBA/Water Works Department before sealing.
24" x 24" R.C MANHOLE SANITARY LAYOUT
900

900

900
4. all inlet to water storage tank ROOF BEAM LEVEL TO ENGR'S DETAIL
must have 150mm float valve
PLUMBING LAYOUT
5. all exposed pipe g.i. class 'B'. KITCHEN LAUNDRY BATH 3 BATH 2 BATH 1
control.
DETAILS
6. all concealed pipe g.i. class 'C'. sink 4"Ø uPVC SOIL PIPE
7. all scour and overflow pipe Draw band besin besin
connected together and discharge. wc wc wc
2"Ø uPVC WASTE PIPE
GROUND FLOOR LEVEL ft ft ft ft
Topered skirt
ASS GRD LEVEL g.t Skala : Dilukis oleh : Tarikh :
ELECTRICAL WORK. FAIQ (ASE) MAY 2019
900

Conc. roof tiles at 30° pitch 3' 0"Ø TEMPORARY SOAKWAY PIT AS SHOWN
1. all electrical work shall be carried out by WITH C/W 3" THK. P.C COVER Disemak oleh : Akitek Bertugas :
TENAGA NASIONAL BERHAD Pipe peneration KJA KJA
registered contractors.
2. all concealed electrical works 22 gauge g.i flashing GRADIENT 1:80 GRADIENT 1:80
be inspected & approved
Cement in fill
IC 1 IC 2 IC 3 IC 4
by TENAGA NASIONAL BERHAD before cealing.
4"Ø UPVC SEWER PIPE DISCH. IC 5 TO IC 5 IC 6 BOMBA SUBMISSION CONTRACT DRAWING
3. all electrical wiring shall be in conduit in TO SEPTIC TANK ECOSEPT ES-3
accordance to bomba requirement. AT GRADIENT 1:80 PLANNING SUBMISSION TENDER DRAWING
BUILDING SUBMISSION CONSTRUCTION DRAWING
SCHEMATIC DIAGRAM OF SANITARY LAYOUT PROPOSED SEPTIC TANK
ECOSEPT MODEL (ES-3)
TO DETAIL PRELIMINARY DRAWING PRELIMINARY
NOT TO SCALE CONSTRUCTION DRAWING
No. Lukisan :

VENT PIPE detail KJA.KN.PP/2019/MDB/ ASE-058-19/2


NOT TO SCALE