Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Unit 4, 144 Edward Avenue, Centurion

P O Box 7661, Centurion, 0046


Tel: +27 (0)12 653-1818/0021 • Fax: +27 (0)12 653-0997
E-mail: frank@civilab.co.za • Website: www.civilab.co.za
Civilab
Civil Engineering Testing Laboratories

Moisture Density Relationship


Project: Lee Ndhlovu - Blu Valley Golf Estate
Project No.: 2016-H-1616 Date: 15 November 2016
Field Reference: TP 1-1 Laboratory Ref.: 1616-1
Depth (m): 0-1.2m Remarks:
Description: -

Compactive Effort: Mod. AASHTO

Percent Water Content (%): 3.3 4.4 5.1 6.2 7.3


Dry Density (kg/m3): 2081 2127 2197 2136 2093

3
Maximum Dry Density: 2206 kg/m Optimum Moisture Content: 5.3 %

2220

2200

2180
Dry Density (kg/m³)

2160

2140

2120

2100

2080
3 3.5 4 4.5 5 5.5 6 6.5 7 7.5
Moisture Content (%)

Analysis according to Method A7 of TMH1 of 1986.


The results relate only to the samples tested.
This report may only be reproduced or published in its full context.
Remarks:

Investment Facility Company 842 (Pty) Limited trading as Civilab. Registration No: 1998/019071/07
BRANCHES: CENTURION • JOHANNESBURG • PIETERMARITZBURG • PINETOWN • PORT ELIZABETH • RUSTENBURG • VRYHEID
Page 1 of 1