Product: EXCAVATOR
Model: 349D2 L EXCAVATOR TAH
Configuration: 349D2 & 349D2 L Excavators TAH00001-UP (MACHINE)
POWERED BY C13 Engine
i02424841
NOTICE
Never remove the fill/vent plug from the hydraulic tank if the oil is hot.
Illustration 1 g00101435
1. Park the machine on level ground. Lower the bucket to the ground with the stick in a vertical position,
as shown.
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/mediasearch/mediaheaderinfoframeset.jsp&calledpa… 1/3
13/9/2019 349D2 & 349D2 L Excavators TAH00001-UP (MACHINE) POWERED BY C13 Engine(SEBP7439 - 28) - Documentation
Illustration 2 g00687286
(A) High temperature range
(B) Low temperature range
3. For a cold machine, maintain the hydraulic oil level in the low temperature range. For a machine that
is at normal operating temperature, maintain the hydraulic oil level in the high temperature range.
Illustration 3 g01097883
Note: Refer to Operation and Maintenance Manual, "General Hazard Information" for information on
containing fluid spillage.
5. Slowly loosen the filler plug in order to relieve any pressure. Add oil, if necessary. See Operation and
Maintenance, "Lubricant Viscosities".
6. Check the O-ring seal of the filler plug. Replace the O-ring seal if the O-ring seal is damaged.