2501

DK Tilbehør
S
GB
Tillbehör
Accessories
Date: 01 SEP 19 P
D Zubehör
F Accessoires Index

Fans and filters Instruments

P2502 P2505

Current transformers Split-core Surge arrester

P2506 P2507

Earthing system Desk constructions

P2508 P2509

CUBIC-Modulsystem A/S Tel +45 9882 2400


Skjoldborgsgade 21 E-mail info@cubic.eu
DK-9700 Broenderslev Web www.cubic.eu
2502
DK Ventilation
S
GB
Fläktar
Fans and filters
Date: 01 SEP 19 P
D Filterlüfter
F Ventilateurs Index

Type :

}
The motors may be
2500-1200
turned, so the fan can be
2500-2500
fitted in the top, and the
2500-2501
filter at the bottom.
2500-3000

Technical data, fans and filters


Fans with filters, type 2500-1200 2500-2500 2500-2501 2500-3000
UL-approved fans with filter (IP54), type 2500-2500UL 2500-3000UL

Fan volume - free air 50 m3/h 100 m3/h 220 m3/h 500 m3/h
Fan volume with one filter 2501-1200 27 m3/h
Fan volume with one filter 2501-2500 36 m3/h 80 m3/h 155 m3/h
Fan volume with one filter 2501-2500UL (IP54) 66 m3/h
Fan volume with two filters 2501-2500 89 m3/h 200 m3/h 390 m3/h
Fan volume with one filter 2501-3000 190 m3/h 345 m3/h
Fan volume with one filter 2501-3000UL (IP54) 300 m3/h
Fan volume with two filters 2501-3000 450 m3/h
Fan volume with two filters 2501-3000UL (IP54) 390 m3/h
Voltage / frequency 115 V (UL) or 230 V - 50-60 Hz
Power absorbed 16 W / 0.13 A 16 W / 0.13 A 40 W / 0.30 A 63 W / 0.30 A
Electrical connection By terminals
Fan, degree of protection IP44
Noise level at 3 m 47/531) dB(A) 47/531) dB(A) 56/581) dB(A) 59/621) dB(A)
Material / colour ABS / RAL7035
Bearings Ball bearings
Temperature limits -10°C - +70°C
Self extinguishing UL94 V0
Filter mats Class EU4/90% dedusting degree according to Eurovent
Dimensions 130X130 mm 255X255 mm 255X255 mm 323X323 mm
1)
At 60 Hz

CUBIC-Modulsystem A/S Tel +45 9882 2400


Skjoldborgsgade 21 E-mail info@cubic.eu
DK-9700 Broenderslev Web www.cubic.eu
2503
DK Ventilation
S
GB
Fläktar
Fans and filters
Date: 01 SEP 19 P
D Filterlüfter
F Ventilateurs Index
Choice of fan Example:

If the quantity of heat to be removed from a panel is The heat (power loss) to be removed is 600 W
known together with the ambient temperature and
the wanted max. temperature inside the panel, the Tamb = 20°C
necessary fan capacity (air quantity in m³/h) can be T0.5 = 45°C
found using the below formula: (Due to the mechanical ventilation the temperature will be
distributed in the entire height of the panel, therefore T0.5 is used)

P x 3.1 600 x 3.1


V= V= = 74.4 m3/h
( Tmax - Tamb ) ( 45 - 20 )

V = Air quantity in m3/h The necessary capacity can be obtained by fitting a


P = Heat in Watt to be removed from fan, type 2500-2500. The fan must be fitted in the bot-
the panel. tom of the panel, and filter, type 2501-2500, must be
T0.5 = Max. wanted air temperature in fitted in top of the panel.
the panel.
Tamb = Ambient temperature (must be
lower than T0.5)

CUBIC-Modulsystem A/S Tel +45 9882 2400


Skjoldborgsgade 21 E-mail info@cubic.eu
DK-9700 Broenderslev Web www.cubic.eu
2504
DK Ventilation
S
GB
Fläktar
Fans and filters
Date: 01 SEP 19 P
D Filterlüfter
F Ventilateurs Index
Fans with filter Exhaust filter Replacement filter Thermostat

2500-1200 2501-1200 2502-1200


2500-2500 2501-2500 2502-2500 2510-0000
2500-2501 2501-2500UL 2502-3000
2500-3000 2501-3000UL

Thermostat, technical data


Mounting: DIN rail
Connection: Terminals
Temp. range: 0-60°C
Contact: 1 NO
6A, 230V AC

Fans with filter  104.5  130 24 41 24

 116
4x ø 4.5
24
2500-1200 2501-1200

 234  255 40 105 40

2500-2500
 226

2501-2500 8x ø 4.5

2500-2501

 302  323 40 120 40

 294

8x ø4.5
2500-3000 2501-3000

CUBIC-Modulsystem A/S Tel +45 9882 2400


Skjoldborgsgade 21 E-mail info@cubic.eu
DK-9700 Broenderslev Web www.cubic.eu
2505
DK Instrumenter
S
GB
Instrument
Instrument
Date: 01 SEP 19 P
D Instrument
F Instruments Index

Multiinstrument 400V

Model: EM210 72D AV5 3X OXX

Views: W, var, PF, phase-sequence, VLL, VLN, A, kWh, kVArh

3801-0001

Mounting methods

Mounted in covering or door Mounted on DIN-rail

Link to the manufacturer's documentation:


www.productselection.net/pdf/uk/em210ds.pdf

CUBIC-Modulsystem A/S Tel +45 9882 2400


Skjoldborgsgade 21 E-mail info@cubic.eu
DK-9700 Broenderslev Web www.cubic.eu
2506
DK Strømtransformere, delbare
S
GB
Strömtransformatorer Delad kärna
Current transformers Split-core
Date: 01 SEP 19 P
D Stromwandler, Teilbar
F Transformateur de courant Split Core Index

CUBIC Item number Description


3802-0151 Current transformer CTD-8S - 150/1A - cl. 1
3802-0200 Current transformer CTD-8S - 200/5A - cl. 3
3802-0301 Current transformer CTD-8S - 300/1A - cl. 1
3802-0400 Current transformer CTD-8S - 400/5A - cl. 1
3802-0401 Current transformer CTD-8S - 400/1A - cl. 1
3802-0600 Current transformer CTD-8S - 600/5A - cl. 1
3802-0601 Current transformer CTD-8S - 600/1A - cl. 1
3802-0800 Current transformer CTD-8S - 800/5A - cl. 1
3802-0801 Current transformer CTD-8S - 800/1A - cl. 1
3802-1000 Current transformer CTD-8S - 1000/5A - cl. 1
3802-1001 Current transformer CTD-8S - 1000/1A - cl. 1
3802-1250 Current transformer CTD-8S - 1250/5A - cl. 1
3802-1251 Current transformer CTD-8S - 1250/1A - cl. 1
3802-1600 Current transformer CTD-8S - 1600/5A - cl. 1
3802-1601 Current transformer CTD-8S - 1600/1A - cl. 1
3802-2000 Current transformer CTD-8S - 2000/5A - cl. 1
3802-2001 Current transformer CTD-8S - 2000/1A - cl. 1

Link to the manufacturer's documentation:


www.productselection.net
S2000

4112-0001

Spacing plate for S2000 4112-0001 4112-0001


current transformator Dimension placed on front placed on rear
10x10 5 5

10x20 4 4

10x30 3 3

10x40 2 2

10x50 1 2

10x60 1 1

4112-0001

CUBIC-Modulsystem A/S Tel +45 9882 2400


Skjoldborgsgade 21 E-mail info@cubic.eu
DK-9700 Broenderslev Web www.cubic.eu
2507
DK Transientbeskyttelse
S
GB
Överspänningsskydd
Surge arrester
Date: 01 SEP 19 P
D Überspannungsschutz
F Parafoudre Index

DEHNventil TNC 255 DEHNventil TNC 255 FM DEHNshield TNC 255 DEHNventil TT 255

3803-0001 3803-0002 3803-0003 3803-0011


SPD according to IEC 61643-11 SPD according to IEC 61643-11 SPD according to IEC 61643-11 SPD according to IEC 61643-11
Class 1+2 Class 1+2 Class 1 Class 1
Earthing system Earthing system Earthing system Earthing system
TN-C TN-C TN-C TT / TN-S
Combined lightning current and surge Combined lightning current and surge Combined lightning current and surge Combined lightning current and surge
arrester. arrester , Signal contact. arrester. arrester.

DEHNventil TT 255 FM DEHNshield TT 255 DEHNguard M TNC 275 DEHNguard M TNC 275 FM

3803-0012 3803-0013 3803-0021 3803-0022


SPD according to IEC 61643-11 SPD according to IEC 61643-11 SPD according to IEC 61643-11 SPD according to IEC 61643-11
Class 1 Class 1 Class 2 Class 2
Earthing system Earthing system Earthing system Earthing system
TT / TN-S TT / TN-S TN-C TN-C
Combined lightning current and surge Combined lightning current and surge
Surge arrester. Surge arrester, Signal contact.
arrester , Signal contact. arrester.

DEHNguard M TT 275 DEHNguard M TT 275 FM DEHNguard M TT CI 275 DEHNguard M TT CI 275 FM

3803-0031 3803-0032 3803-0041 3803-0042


SPD according to IEC 61643-11 SPD according to IEC 61643-11 SPD according to IEC 61643-11 SPD according to IEC 61643-11
Class 2 Class 2 Class 2 Class 2
Earthing system Earthing system Earthing system Earthing system
TT / TN-S TT / TN-S TT / TN-S TT / TN-S
Surge arrester, with integrated Surge arrester, with integrated
Surge arrester. Surge arrester, Signal contact.
backup fuses. backup fuses, Signal contact.

Link to the manufacturer's documentation:


www.dehn-international.com

CUBIC-Modulsystem A/S Tel +45 9882 2400


Skjoldborgsgade 21 E-mail info@cubic.eu
DK-9700 Broenderslev Web www.cubic.eu
2508
DK Jordings- & kortslutningsudstyr
S
GB
Jordningsverktyg
Earthing- & short-circuiting units
Date: 01 SEP 19 P
D Erdungs- & Kurzscliessvorrichtungen
F Mise à la terre Index
Short-circuiting busbar 300 mm, single S2000

3807-0300

Short-circuiting busbar 650 mm, double S2000

3807-0650

Earthing and Short-Circuiting Devices.


SQ screw-type adapter Earthing handle for T pin shafts
Safety products for working according to the five safety rules.
The products fits perfectly to use in the CUBIC system and they are
designed according to EN/IEC 61230 .
Fixed Ball Points Ø20mm. can easily be mounted directly on the
PE-Busbar.
Clamping points can easily be mounted directly on the S2000
busbar system by using brackets for single or double S2000 system.
Before service or other maintenance on the panel, can the short-
circuiting busbar incl. wire easily be mounted by using earthing
stick and adaptor.
During service and maintenance you can now be sure that the panel
is de-energized.

3807-0002 3807-0003

Bracket for clamping point, Bracket for clamping point, Fixed clamping point for Fixed ball point Ø20, angled
single S2000 double S2000 busbars with terminal lug

3807-0004

Fixed ball point Ø20, straight


with female thread M10

0879-0001 0879-0002 3807-0001 3807-0005

CUBIC-Modulsystem A/S Tel +45 9882 2400


Skjoldborgsgade 21 E-mail info@cubic.eu
DK-9700 Broenderslev Web www.cubic.eu
2509
DK Pultopbygninger
S
GB
Pulpetkonstruktioner
Desk constructions
Date: 01 SEP 19 P
D Pultaufbau
F Construction de pupitres Index

Various desk constructions

Up to
IP54

≤ IP4X

10°
A
)
92
E x1
M
les(
Door, type TXxX o du
36 M =m
W

M A B C D E
P2-XX 192 384 414,2 396,5 102
P3-XX 192 576 603,3 951,5 68
Type no.:
B 2 3 4 5 6 7 8 9 10
M
2 P2-02 P2-03 P2-04 P2-05 P2-06 P2-07 P2-08 P2-09 P2-10
3 P3-02 P3-03 P3-04 P3-05 P3-06 P3-07 P2-08 P2-09 P2-10

CUBIC-Modulsystem A/S Tel +45 9882 2400


Skjoldborgsgade 21 E-mail info@cubic.eu
DK-9700 Broenderslev Web www.cubic.eu