Professional Documents
Culture Documents
Bunker Supporting Structure & Operating Platform Layout
Bunker Supporting Structure & Operating Platform Layout
Bunker Supporting Structure & Operating Platform Layout
PROJECT : HTIF-145,
LOCATION : SURAT,GUJARAT
1
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
INDEX
1. Introduction...................................................................................................................................... 3
2. Scope of the work............................................................................................................................. 3
3. Reference Codes and Standards (latest editions and amendments)...............................................3
4. Materials........................................................................................................................................... 3
5. Design Philosophy & Assumptions................................................................................................... 3
6. Basic Geometry................................................................................................................................ 4
7. Loading............................................................................................................................................ 7
Dead Load................................................................................................................................... 7
Live Loads.................................................................................................................................... 7
Equipment Operating load........................................................................................................... 7
8. Layout and General Arrangement (Member Properties).................................................................8
9. Member Dimensions...................................................................................................................... 16
10. Loads On structure..................................................................................................................... 23
Seismic load in X direction......................................................................................................... 23
Seismic load in Z direction......................................................................................................... 24
Dead Load................................................................................................................................ 25
Live Load.................................................................................................................................. 26
Equipment Operating Load...................................................................................................... 27
11.Unity Stress Ratio.............................................................................................................................. 28
12.STAAD Out-put File........................................................................................................................... 29
2
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
1. Introduction
The objective of this document is to present analysis and design calculations for Heater and Bunker
Supporting & operating platform Structure.
4. Materials
Following design philosophy &assumptions have been used for analysis & design of Heater and Bunker
Supporting & operating platform Structure calculations.
2) The complete structural analysis of the structure for the proposed loading is carried out through
STAAD.Pro.
3
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
6. Basic Geometry
A
1 2.93m 5.39m
GRID PLAN
2 5.39m
4
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER SUPPORTING AND OPERATING PLATFORM
STRUCTURE
3D Rendered View
5
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER SUPPORTING AND OPERATING PLATFORM
STRUCTURE
FRONT VIEW
6
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER SUPPORTING AND OPERATING PLATFORM
STRUCTURE
7
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
7. Loading.
Dead Load
Dead Load includes self-weight of the structure, the weight of the platforms , handrail and
ladders etc.
Assuming dead weight of grating = 0.5 kN/m2,
Assuming weight of Railing = 0.18 kN/m
staircase weight = 1.5 kN/m
Live Loads
The imposed load on landing platform & operating platform is considered as 3 KN/m2.
staircase weight = 3 kN/m
8
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
Property Section
1 ISA50X50X6
2 ISA50X50X6 SD
3 ISMC75
4 ISMB150
5 ISMC150
6 ISMC100 FR
7 Cir 3.94
8 ISMB200
9 BUNKER
MC250+180X12PL+50MM
10
SPACEING
11 ISA65X65X6 SD
9
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
R9
R10
R10
R6
R10
R10
R4
R4
R4
R4
R8 R8 R8 R8 R8 R8 R8 R8 R8 R8 R4
R10
R10
R10
R10
R8 R8 R8 R8 R8 R4
R10
R10
R10
R10
R4
R10
R10
R7
10
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
R9
R10
R10
R6
R10
R10
R8 R8 R8 R8 R8 R4
R10
R10
R10
R4 R8 R8 R8 R8 R8 R4
R10
R10
R10
R10
R10
R10
Load 1
11
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
R9
R10
R10
R6 R6
R10
R10
R8 R8 R8 R8 R8 R8
R10
R10
R10
R4 R4 R4 R4 R4
R10
R10
R10
R10
R10
R10
12
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
R9
R10
R10
R6 R6
R10
R10
R8 R8 R8 R8 R8 R8 R4
R10
R10
R10
R10
R4 R4 R4 R4
R10
R10
R10
R10
R10
R10
13
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
R8 R8 R8 R8 R8
R4
R4
R4
R4
R4
R4
R3 R4 R4 R4 R4 R4 R3
R4
R4
R4
R4
R4
R4
R4
R4
R4
R3 R4 R4 R4 R4 R3
R4
R4
R4
R4
R4
R4
R4 R8 R8 R8 R8 R8
R4
R4
Lo
14
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
R5 R5
R5
R5
R5
R5
R8 R8 R8 R8 R8 R8 R8 R8 R8
R8
R5
R3
R5
R3
R3
R5
R3
R5
R8
R8 R8 R8 R8 R8 R8 R8 R8 R8 R8 R4
R4
R4
R4
R4
R5 R5
R8
R8
R4
R4
R4
R4
R3 R3 R3 R3 R3 R3
R8
R4
R4
R4
R4
R8
R3 R3 R3 R3 R3 R3
R8
R8
R4
R4
R4
R4
R8
R8
R3 R3 R3 R3 R3 R3
R8
R4
R4
R4
R4
R8
R8 R8 R8 R8 R8 R4
R4
R4
Plan At 6.195 m Level
Y X
Z
Loa
15
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
R6
R6
R6
R6
R9
R9
16
R9
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
9. Member Dimensions
5.39 m
1.5 m
1.5 m
5.39 m
2.4 m
2.4 m
1m 0.20.415
m 0.29
m 0.495
m m0.791 m
0.295
0.29
m m0.615 m 1m 1.2 m
1m
1m
1.69 m
1.69 m
1.04 m 1.44 m 0.435 m 1.44 m 1.04 m 1.2 m
1.04 m
0.16 m 1.04 m
0.696 m
2.93 m
2m
1.46 m
1.46 m
Y
Z X
Load
17
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
5.39 m
1.5 m
1.5 m
5.39 m
2.4 m
2.4 m
1.2 m 1.2 m 0.791 m 1.2 m 1m 1.2 m
1m
2.69 m
1.69 m
1.2 m 1.04 m 1.44 m 0.792 m 1.08 m 1.04 m 1.2 m
0.16 m 1.04 m
0.16 m 1.04 m
2m
2m
Loa
18
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
3.01 m
1.5 m
1.5 m
1.5 m 1.5 m
2.4 m
2.4 m
1m 0.6 m 0.756 0.147
m 0.678
m m 0.825 m
1m
2.69 m
1.69 m
1.02 m 0.483 m
0.517 m 0.986 m 1.2 m
1.04 m
0.16 m 1.04 m
0.696 m
2m
1.46 m
19
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
3.01 m
1.5 m
1.5 m
1.5 m 1.5 m
2.4 m
2.4 m
1m 0.6 m 0.756 0.147
m 0.678
m m 0.825 m 1m
1m
1m
1.69 m
1.69 m
1.02 m 0.483 m
0.517 m 0.986 m
0.16 m 1.04 m
0.16 m 1.04 m
2m
2m
20
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
1.02 m
1.02 m
1.02 m
1.02 m
1.02 m
1.04 m 0.357 m 1.08 m 0.435 m0.357 m 1.08 m 1.04 m 1.2 m
0.483 m
0.483 m
1m
1m
1m
1m
1m
0.517 m
0.517 m
1.04 m 0.357 m 1.08 m 0.792 m 1.08 m 1.04 m 1.2 m
0.986 m
0.986 m
0.986 m
0.986 m
0.986 m
0.986 m
1.2 m 1.04 m 1.44 m 0.792 m 1.08 m 1.04 m 1.2 m
1.2 m
1.2 m
Y X
Load 1
Z
21
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
0.208 m
0.208 m
0.208 m
0.208 m
0.29 m 0.29 m
1.2 m 0.415 m 0.29 m 0.495 m 0.791 m 0.295 m0.29 m 0.615 m 1m
1m
1m
1m
1m
1m
1m
1m
1m
1m
1m
0.174 m
0.174 m
0.174 m
0.174 m
1m 0.2 m0.415 m 0.29 m 0.495 m 0.791 m 0.295 m0.29 m 0.615 m 1m 1.2 m
1.2 m 1.2 m
0.6 m
0.6 m
0.426 m
0.426 m
0.426 m
0.426 m
1.2 m 1.2 m 0.791 m 1.2 m 1m 1.2 m
0.756 m
0.756 m
0.756 m
0.756 m
0.825 m
0.825 m
0.825 m
0.825 m
0.825 m
0.825 m
0.825 m
0.825 m
Y X
Z
Load
22
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
1.5 m
1.5 m 5.39 m
5.39 m
5.39 m
3.01 m
23
5.39 m
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER SUPPORTING AND OPERATING PLATFORM
STRUCTURE
0.250 kN 0.051 kN
0.050 kN 0.035 kN
0.051 kN 0.045 0.054 kN
kN
0.250 kN 0.045 kN
0.062 kN 0.250 kN 0.055 kN
0.047
0.039 kNkN
0.045 0.046 kN
kN 0.084 kN 0.061 kN
0.045 kN kN
0.054 0.090
0.174 kNkN
0.095 kN 0.053 kN
0.051 kN 0.044
0.084 kN kN
0.059 kN 0.112 kN 0.041
0.081 kN kN 0.066 kN
0.089 kN 0.045 kN
0.055 kN 0.088 kN 0.048 kN
0.076 kN
0.095 kN0.095
0.033
0.105
0.045 kN
kN
kN kN 0.048 kN
0.097 kN 0.075 kN
0.065 kN 0.068 kN
0.250 kN 0.065 kN 0.092 kN
0.068 kN 0.048 kN
0.149 kN 0.055 kN 0.082 kN 0.074 kN
0.084 kN 0.082 kN
0.052 kN kN
0.035 0.070 kN 0.015 kN
0.046 kN 0.102 kN 0.070 kN 0.046 kN
0.064 kN 0.351 0.213
0.045kNkN
0.080 kN kN 0.025 kN
0.024 kN
0.031 kN
0.014 kN 0.016 kN 0.023 kN
0.012 kN
0.167 kN 0.048 kN 0.004 kN
0.029 0.006 kN 0.030 kN 0.015 kN
0.025 kN 0.025 kN kN
0.036 kN 0.035 kN
0.034 kN 0.028 kN 0.044 kN
0.044 kN 0.023 kN
0.041 kN 0.032 kN
0.017 kN 0.021 kN
0.013 kN 0.034
0.026 kNkN 0.024 kN
0.006 kN 0.016 kN 0.004 kN
0.006 kN
0.026 kN
0.020 kN
0.133kN
0.058 kN
0.065 kN
0.016 kN
0.004 kN
0.011 kN 0.006 kN
Y
X
Z 24
Load 1
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER SUPPORTING AND OPERATING PLATFORM
STRUCTURE
0.250 kN
0.351 kN
0.250 kN
0.174 kN 0.051 kN
0.112 kN 0.050 kN
0.090
0.054 kN
0.095 kN 0.213 kN
0.051 kN 0.062 kN 0.084 kN 0.035
0.055 kN
0.045
0.045 kN kN
0.149 kN 0.084
0.047
0.089 kN kN
kN
0.105 kN 0.081 kN 0.061 kN
0.095
0.088 kN
kN 0.039 kN
0.054 0.046
kN kN 0.097 kN
0.095
0.0590.045
0.051 kNkN
kN
kN0.045 0.053 kN
0.076 kN 0.066 kN
0.044 kN 0.092 kN 0.075 kN
0.041 kN
0.055 kN 0.065 kN 0.045
0.068 kN
kN 0.048 kN
0.065 0.048
0.068kNkN 0.082 kN
0.167 kN 0.045 kNkN
0.084
0.033 kN
0.102kN
kN 0.082 kN 0.074 kN
0.055 kN 0.048 kN
0.070 kN
0.070 kN
0.052 kN 0.080 kN
0.064 kN
0.046 kN 0.035 kN 0.046 kN
0.045 kN 0.015 kN
0.024 kN
0.025 kN
0.048 kN 0.031 kN
0.023 kN
0.014 kN 0.016
0.030kN
kN
0.012 kN 0.029 kN
0.036 0.025
kN kN 0.035 kN
0.034
0.025 kN 0.044 kN 0.004 kN 0.044 kN 0.015 kN
0.133kN
kN 0.041 0.028
kN kN 0.006 kN
0.032 kN 0.023 kN
0.034 kN
0.017 kN 0.026 kN 0.021 kN
0.024 kN
0.013 kN
0.016 kN 0.026 kN
0.006
0.058 kN kN 0.004 kN
0.006 kN
0.065 kN
0.020 kN
0.016 kN
0.011 kN 0.004 kN
0.006 kN
Y
X
Z 25
Load 2
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER SUPPORTING AND OPERATING PLATFORM
STRUCTURE
Dead Load
-0.018-2.600
MTon/mkN -3.440 kN
-2.600 kN -0.018 MTon/m
-1.870 kN
Z
X 26
Load 3 (SELF Y)
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER SUPPORTING AND OPERATING PLATFORM
STRUCTURE
Live Load
-0.153 MTon/m
-0.153 MTon/m
-0.121 MTon/m -0.153 MTon/m
-0.092 MTon/m
-0.121 MTon/m
-0.032
-0.032
-0.045
MTon/m
MTon/m
MTon/m -0.092 MTon/m-0.116 MTon/m
-0.092 MTon/m
-0.076 MTon/m -0.116
-0.065 MTon/m
MTon/m
-0.184 -0.126
MTon/m MTon/m
-0.092
-0.027 MTon/m
MTon/m -0.116 MTon/m
-0.153 MTon/m -0.032 MTon/m 2*-0.045 -0.027
-0.044MTon/m
MTon/m MTon/m
-0.063 MTon/m
-0.032 MTon/m -0.092 MTon/m-0.027 MTon/m
-0.184 MTon/m-0.126
-0.116 MTon/m
MTon/m
-0.153 MTon/m -0.027 MTon/m 2*-0.126 MTon/m
-0.184 MTon/m
-0.076
-0.092 -0.116
MTon/m
MTon/m MTon/m
-0.065
-0.184 MTon/m
MTon/m
-0.153 MTon/m -0.092
-0.092 MTon/m
-0.063
MTon/m -0.092
MTon/m
-0.044 MTon/m MTon/m -0.121 MTon/m 2*-0.126 MTon/m-0.153 MTon/m
-0.044 MTon/m -0.184 MTon/m -0.126 MTon/m
-0.184 MTon/m-0.121
-0.116 MTon/m
-0.092 MTon/m -0.092 MTon/m -0.184 MTon/m
-0.121 MTon/m -0.126 MTon/m
-0.116 MTon/m -0.121 MTon/m -0.153
-6.870 kN MTon/m
-0.092 MTon/m -0.184 MTon/m
-0.126 MTon/m
-0.116 MTon/m
2*-0.126 MTon/m -0.156 MTon/m
-0.156 MTon/m
-0.126 MTon/m -0.156 MTon/m
-0.153
-0.156 MTon/m
-0.153
-0.153
-0.151 MTon/m
-0.153 MTon/m
-0.121 MTon/m -0.151-0.153 MTon/m
-0.156 MTon/m -0.121 MTon/m -0.151 MTon/m
-0.153 MTon/m -0.153 MTon/m
-0.151
-0.121 MTon/m -0.151 MTon/m
-0.156 MTon/m -0.055 MTon/m -0.121 MTon/m-0.151 MTon/m
-0.153 -0.153
-0.151
-0.055-0.151
MTon/m MTon/m
MTon/m
-0.153
-0.151 MTon/m
-0.151 MTon/m
-0.151 MTon/m
-5.190 kN -6.870 kN
-5.190 kN
-3.733 kN
27
Y
X
Z Load 4
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER SUPPORTING AND OPERATING PLATFORM
STRUCTURE
1.795 MTon/m
-2.932 MTon/m
-1.795 MTon/m
-1.795 MTon/m
-2.932 MTon/m
1.795 MTon/m
-0.850
-0.850 kN kN
-0.850 kN kN
-0.850
-0.850 kN
-0.850
-0.850 kN kN -0.850
-0.850 kN kN
-0.850 kN
-0.850
-0.850 kN kN
-0.850 kN
-0.850 kN -0.850 kN
-0.850
-0.850 kN kN
-0.850 kN
-0.850
-0.850 kN kN
-1.830 kN
-1.830 kN
-1.830 kN
-1.830 kN
-1.830 kN
-1.830 kN
Y 28
X
Z Load 5
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER SUPPORTING AND OPERATING PLATFORM
STRUCTURE
0.63
0.37
0.643
0.627
0.378
0.37
0.636
0.00963
0.388
0.371
0.293
0.051 2
0.015 7
0.0894 0.0 10 7
0.422
0.376
0.291
0.294
0.201 0.207
0.0 54 2
0.189 0.415
0.393
0.403
0.0 14 2
0. 01 13
0.38
0.197 0.381
0.395
0.592
0.252
0.303
0.205 0.348
0.577
0.592
0.573
Y
X 29
Z Load 11
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
PAGE NO. 1
****************************************************
* *
* STAAD.Pro V8i SELECTseries5 *
* Version 20.07.10.41 *
* Proprietary Program of *
* Bentley Systems, Inc. *
* Date= NOV 6, 2019 *
* Time= 15:38:46 *
* *
* USER ID: SP Engg-Corp Pvt Ltd *
****************************************************
1. STAAD SPACE
INPUT FILE: Bunker Support Structure - 09.10.2019-1.STD
2. START JOB INFORMATION
3. ENGINEER DATE 04-10-19
4. ENGINEER NAME SSN
5. END JOB INFORMATION
6. INPUT WIDTH 79
7. UNIT METER KN
8. JOINT COORDINATES
9. 1 0 0.3 0; 2 5.391 0.3 0; 3 0 0.3 3.006; 4 5.391 0.3 3.006; 5 0 3.5 0
10. 6 5.391 3.5 0; 7 0 3.5 3.006; 8 5.391 3.5 3.006; 9 0 6.195 0; 10 5.391 6.195 0
11. 11 0 6.195 3.006; 12 5.391 6.195 3.006; 13 0 8.595 0; 14 5.391 8.595 0
12. 15 0 8.595 3.006; 16 5.391 8.595 3.006; 17 0 10.097 0; 18 5.391 10.097 0
13. 19 0 10.097 3.006; 20 5.391 10.097 3.006; 21 1.04 3.5 0; 22 1.04 3.5 3.006
14. 23 0 3.5 2.02; 24 0 3.5 1.02; 25 5.391 3.5 1.02; 26 5.391 3.5 2.02
15. 27 1.04 3.5 2.02; 28 1.397 3.5 1.02; 29 1.04 3.5 1.02; 30 2.477 3.5 1.02
16. 31 3.269 3.5 1.02; 32 4.351 3.5 1.02; 33 2.477 3.5 0; 34 2.477 3.5 2.02
17. 35 2.477 3.5 3.006; 36 3.269 3.5 2.02; 37 3.269 3.5 3.006; 38 4.351 3.5 0
18. 39 4.351 3.5 2.02; 40 4.351 3.5 3.006; 41 6.591 3.5 0; 42 6.591 3.5 3.006
19. 43 6.591 3.5 1.02; 44 6.591 3.5 2.02; 45 5.391 2.3 0; 46 5.391 2.3 3.006
20. 47 0 6.195 0.6; 48 0 6.195 1.356; 49 0 6.195 2.181; 50 0 6.195 -1.
21. 51 5.391 6.195 -1; 52 6.591 6.195 0; 53 6.591 6.195 3.006
22. 54 5.391 6.195 4.006; 55 6.591 6.195 4.006; 56 5.391 6.195 0.6
23. 57 6.591 6.195 0.6; 58 5.391 6.195 1.356; 59 6.591 6.195 1.356
24. 60 5.391 6.195 2.181; 61 6.591 6.195 2.181; 62 1.2 6.195 0; 63 1.2 6.195 3.006
25. 64 1.2 6.195 0.6; 65 1.2 6.195 1.356; 66 1.2 6.195 2.181; 67 1.2 6.195 -1.
26. 68 2.4 6.195 0; 69 2.4 6.195 3.006; 70 2.4 6.195 0.6; 71 2.4 6.195 1.356
27. 72 2.4 6.195 2.181; 73 2.4 6.195 -1; 74 3.191 6.195 0; 75 3.191 6.195 3.006
28. 76 3.191 6.195 0.6; 77 3.191 6.195 1.356; 78 3.191 6.195 2.181
29. 79 3.191 6.195 -1; 80 4.391 6.195 0; 81 4.391 6.195 3.006; 82 4.391 6.195 0.6
30. 83 4.391 6.195 1.356; 84 4.391 6.195 2.181; 85 4.391 6.195 -1.
31. 86 1.615 6.195 -1; 87 1.905 6.195 -1; 88 1.615 6.195 -1.208
32. 89 1.905 6.195 -1.208; 90 1.2 6.195 0.174; 91 2.4 6.195 0.174
33. 92 1.615 6.195 0; 93 1.905 6.195 0; 94 3.486 6.195 0; 95 3.486 6.195 -1.
34. 96 3.776 6.195 0; 97 3.776 6.195 -1; 98 3.486 6.195 -1.208
35. 99 3.776 6.195 -1.208; 100 3.191 6.195 0.174; 101 4.391 6.195 0.174
36. 102 0 5.195 0; 103 5.391 5.195 0; 104 5.391 5.195 3.006; 105 0 3.5 4.206
37. 106 0 2.3 3.006; 109 0 2.46 0; 110 5.391 2.46 0; 113 0 2.46 3.006
38. 114 5.391 2.46 3.006; 117 0 3.5 1.503; 118 0 6.195 1.503; 119 0 8.595 1.503
STAAD SPACE -- PAGE NO. 2
39. 121 5.391 3.5 1.503; 122 5.391 6.195 1.503; 123 5.391 8.595 1.503
40. 129 1.397 3.5 2.02; 154 -1.2 3.5 3.006; 157 -2.93 0.3 0; 158 -2.93 1.764 0
41. 159 0 1.764 0; 160 -1.2 3.5 4.206; 161 2.912 3.5 1.02; 162 2.912 3.5 0
42. 165 1 6.195 0
43. MEMBER INCIDENCES
44. 1 1 159; 2 2 45; 3 3 106; 4 4 46; 5 5 21; 6 6 25; 7 5 24; 8 7 22; 9 5 102
45. 10 6 103; 11 7 11; 12 8 104; 13 9 165; 14 11 63; 15 10 56; 16 9 47; 17 9 13
46. 18 10 14; 19 11 15; 20 12 16; 23 13 119; 24 14 123; 25 13 17; 26 14 18
47. 27 15 19; 28 16 20; 29 21 33; 30 22 35; 31 23 7; 32 24 117; 33 25 121
48. 34 24 29; 35 26 8; 36 23 27; 37 27 129; 38 22 27; 39 28 30; 40 29 27; 41 29 28
49. 43 30 161; 44 31 32; 45 32 25; 46 33 162; 47 30 33; 48 34 36; 49 30 34
50. 50 35 37; 51 34 35; 52 36 39; 54 37 40; 55 36 37; 56 38 6; 57 32 38; 58 39 26
51. 59 32 39; 60 40 8; 61 39 40; 62 6 41; 63 8 42; 64 25 43; 65 26 44; 66 41 43
30
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
95. *_BUNKER-BEAM
96. *232.72 231.22 0.503244 20 5.818 1.52362E+006 4096.2 58.0689 11849.7 -
97. *409.62 174.54 174.54 16685.2 546.661 580689 230.214
98. ***************************************
99. *_BUNKERBEAM
100. *265.36 285.61 0.46455 20.29 6.53918 2.62422E+006 4099.57 61.9241 16596.5 -
101. *405.436 199.02 199.02 23109.8 550.989 619241 284.681
102. **********************************
103. *BUNKER
104. *244.72 206.21 0.593376 19.99 6.12106 1.19186E+006 4475.48 100.431 -
105. *9973.76 447.548 183.54 183.54 14507.8 618.679 1.00431E+006 205.023
106. ********************************
107. *1
108. *265.12 284.6 0.465777 20.29 6.53327 2.60381E+006 4099.57 61.8956 16510.1 -
109. *405.422 198.84 198.84 23005.8 550.969 618956 283.668
110. *************************************************
111. END
112. ****************************************************************
113. ****************************************************************
114. START GROUP DEFINITION
115. FLOOR
116. _FFL_3.5M_LVL 5 TO 8 30 TO 41 43 TO 45 48 TO 52 54 TO 68 204 226 239 256 259 -
117. 260 290 303 310 311 313 315
118. _FFL_6.195M_LVL 13 TO 16 73 TO 97 99 102 105 TO 109 111 114 TO 135 -
119. 137 TO 146 148 TO 164 208 216 228 241 322
120. _FFL_6.195M_1LVL 98 100 110 112 124 125 129 130 134 135 139 140
121. JOINT
122. END GROUP DEFINITION
123. **************************************************
124. UNIT METER KN
31
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
151. CONSTANTS
152. BETA 90 MEMB 1 TO 4 9 TO 12 17 TO 20 25 TO 28 69 70 165 TO 167 205 211 212 -
153. 219 220 308
154. MATERIAL STEEL MEMB 1 TO 20 23 TO 41 43 TO 52 54 TO 102 105 TO 206 -
155. 208 TO 214 216 219 220 222 223 226 228 230 TO 236 239 241 243 TO 249 256 -
156. 259 260 290 298 300 TO 304 308 TO 317 322 327 TO 330
157. MATERIAL CONCRETE MEMB 307
158. ************
159. *************************
160. *****************************************************************
161. ************
162. ***************************************************************
163. *************************************
164. **********
165. **********
166. **********
167. ***
168. ************************
169. MEMBER PROPERTY INDIAN
170. 173 TO 203 312 TABLE ST ISA50X50X6
171. 71 72 168 TO 172 206 209 210 213 214 222 223 235 236 244 245 304 327 TO 329 -
172. 330 TABLE SD ISA50X50X6
173. 34 36 45 58 64 65 86 88 90 92 94 96 99 TO 101 105 TO 107 111 TO 113 -
174. 117 TO 119 121 126 131 136 TABLE ST ISMC75
175. 6 7 31 TO 33 35 37 TO 41 43 44 47 TO 49 51 52 55 57 59 61 TO 63 66 TO 68 79 -
176. 80 TO 84 87 91 95 122 TO 125 127 TO 130 132 TO 135 137 TO 140 145 146 159 -
177. 160 204 226 239 256 259 260 290 303 309 TO 311 313 315 TABLE ST ISMB150
178. 143 144 147 149 151 152 157 158 161 TO 164 TABLE ST ISMC150
179. 23 24 230 243 316 317 TABLE FR ISMC100
180. MEMBER PROPERTY INDIAN
181. 307 PRIS YD 0.1
182. 5 8 13 TO 16 29 30 46 50 54 56 60 73 TO 78 85 89 93 97 98 102 108 TO 110 114 -
183. 115 TO 116 120 141 142 148 150 153 TO 156 208 216 228 241 314 -
184. 322 TABLE ST ISMB200
185. MEMBER PROPERTY INDIAN
186. 298 300 TO 302 UPTABLE 1 BUNKER
187. MEMBER PROPERTY INDIAN
188. 1 TO 4 9 TO 12 17 TO 20 25 TO 28 69 70 165 TO 167 205 211 212 219 220 -
189. 308 UPTABLE 1 MC250+180X12PL+50MMSPACEING
190. 231 TO 234 246 TO 249 TABLE SD ISA65X65X6
191. ***
192. **********
193. *******************
194. SUPPORTS
195. 1 TO 4 157 FIXED
196. *********************************************
197. MEMBER RELEASE
32
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
198. 5 TO 8 15 16 23 24 34 36 TO 38 41 43 45 48 52 58 62 TO 66 76 TO 79 81 82 84 -
199. 86 88 90 92 94 96 99 TO 101 105 TO 107 111 TO 113 117 TO 119 121 122 126 -
200. 127 131 132 136 137 147 149 151 161 TO 163 260 290 298 300 315 START MY MZ
201. 31 34 TO 36 39 45 47 48 51 52 55 TO 58 60 61 64 65 68 75 84 86 88 90 -
202. 92 TO 94 96 99 TO 101 105 TO 107 111 TO 113 117 TO 121 125 126 130 131 135 -
203. 136 140 147 149 151 161 TO 163 230 243 256 259 260 298 300 315 END MY MZ
204. ********************************************************
205. MEMBER TRUSS
206. 71 72 168 TO 203 206 209 210 213 214 222 223 231 TO 236 244 TO 249 304 312 -
STAAD SPACE -- PAGE NO. 5
33
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
263. *******************************************************************************
264. *****************************************************
265. ***********************************************
266. LOAD 1 LOADTYPE NONE TITLE SEISMIC X
267. 1893 LOAD X 1
268. PERFORM ANALYSIS
P R O B L E M S T A T I S T I C S
-----------------------------------
*********************************************************
* *
* TIME PERIOD FOR X 1893 LOADING = 0.47069 SEC *
* SA/G PER 1893= 3.500, LOAD FACTOR= 1.000 *
* FACTOR V PER 1893= 0.1050 X 735.23 *
* *
*********************************************************
269. CHANGE
270. ******************************************************************************
271. LOAD 2 LOADTYPE NONE TITLE SEISMIC Z
272. 1893 LOAD Z 1
273. PERFORM ANALYSIS
STAAD SPACE -- PAGE NO. 7
*********************************************************
* *
* TIME PERIOD FOR Z 1893 LOADING = 0.47069 SEC *
* SA/G PER 1893= 3.500, LOAD FACTOR= 1.000 *
* FACTOR V PER 1893= 0.1050 X 735.23 *
* *
*********************************************************
274. CHANGE
275. ********
276. *******************************************************************************
277. LOAD 3 LOADTYPE NONE TITLE DEAD LOAD
278. SELFWEIGHT Y -1
279. *********FLOOR DEAD LOAD=50 KG/SQ.M(GRATING/CHQ. PLATE)********
280. ONEWAY LOAD
281. _FFL_3.5M_LVL ONE -0.5 GY
*WARNING: THERE ARE ONE OR MORE SQUARE PANELS FOUND WHERE ONE WAY LOAD HAS NOT BEEN GENERATED.
282. _FFL_6.195M_LVL ONE -0.5 GY
283. _FFL_6.195M_1LVL ONE -0.5 GY
284. *********STAIRCASE LOAD=150KG/M2******************************
285. MEMBER LOAD
286. 82 204 CON GY -3.44
287. 309 CON GY -1.87 1.69
288. 303 309 CON GY -2.6 0.68
289. **********RAILING LOAD=0.18KN/M****************
290. 5 7 14 16 30 32 39 41 43 44 50 54 56 57 60 62 63 66 TO 68 73 TO 79 81 83 84 -
291. 87 91 95 98 102 108 110 114 116 120 142 156 216 226 228 256 310 311 313 -
34
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
35
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
419. LOAD COMB 134 ( + 0.75 EQ_Z + 0.75 DL + 0.38 LL + 0.75 EEL)
420. 2 0.75 3 0.75 4 0.38 6 0.75
421. LOAD COMB 135 ( - 0.75 EQ_Z + 0.75 DL + 0.38 LL + 0.75 EEL)
422. 2 -0.75 3 0.75 4 0.38 6 0.75
423. *****
424. ******FOR DEFLECTION PER IS-800-1984 & IS-875-PART-V
425. LOAD COMB 1000 ( + DL + LL)
426. 3 1.0 4 1.0
427. LOAD COMB 1001 ( + DL + LL + EOL)
428. 3 1.0 4 1.0 5 1.0
429. LOAD COMB 1002 ( + DL + LL + EEL)
430. 3 1.0 4 1.0 6 1.0
431. LOAD COMB 1003 ( + DL + LL + ETL)
432. 3 1.0 4 1.0 7 1.0
433. LOAD COMB 1004 ( + DL + EOL + WL_+X)
434. 3 1.0 5 1.0 8 1.0
36
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
SELFWEIGHT Y -1.000
37
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
38
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
82 -3.4400 GY 0.50
204 -3.4400 GY 0.60
309 -1.8700 GY 1.69
303 -2.6000 GY 0.68
309 -2.6000 GY 0.68
5 -0.1800 GY 0.00 1.04
7 -0.1800 GY 0.00 1.02
14 -0.1800 GY 0.00 1.20
16 -0.1800 GY 0.00 0.60
30 -0.1800 GY 0.00 1.44
32 -0.1800 GY 0.00 0.48
39 -0.1800 GY 0.00 1.08
39
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
40
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
41
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
82 -6.8700 GY 0.50
204 -6.8700 GY 0.60
309 -3.7332 GY 1.69
STAAD SPACE -- PAGE NO. 18
42
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
FOR LOADING - 3
APPLIED JOINT EQUIVALENT LOADS
JOINT FORCE-X FORCE-Y FORCE-Z MOM-X MOM-Y MOM-Z
1 0.00000E+00-8.79880E-01 5.74682E-09 0.00000E+00 0.00000E+00 0.00000E+00
2 0.00000E+00-1.12804E+00 5.74682E-09 0.00000E+00 0.00000E+00 0.00000E+00
3 0.00000E+00-1.12804E+00-5.74682E-09 0.00000E+00 0.00000E+00 0.00000E+00
4 0.00000E+00-1.12804E+00-5.74682E-09 0.00000E+00 0.00000E+00 0.00000E+00
5 0.00000E+00-1.87442E+00 5.25429E-10 0.00000E+00 0.00000E+00 0.00000E+00
6 0.00000E+00-2.10447E+00 5.25429E-10 0.00000E+00 0.00000E+00 0.00000E+00
7 0.00000E+00-5.16290E+00-5.25429E-10 5.33607E-01 0.00000E+00 3.49598E-01
8 0.00000E+00-2.09431E+00-5.25429E-10 0.00000E+00 0.00000E+00 0.00000E+00
9 0.00000E+00-2.34489E+00-2.60611E-09 0.00000E+00 0.00000E+00-5.30503E-02
10 0.00000E+00-2.54078E+00-2.60611E-09 0.00000E+00 0.00000E+00 5.30503E-02
11 0.00000E+00-3.02440E+00 2.60611E-09 0.00000E+00 0.00000E+00-7.47425E-02
12 0.00000E+00-3.71867E+00 2.60611E-09 0.00000E+00 0.00000E+00-2.04525E-02
13 0.00000E+00-2.56457E+00-3.56320E-09 0.00000E+00 0.00000E+00-4.53961E-01
14 0.00000E+00-2.56457E+00-3.56320E-09 0.00000E+00 0.00000E+00 4.53961E-01
43
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
44
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
X = 0.268140669E+01
Y = 0.619098888E+01
Z = 0.152686214E+01
45
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
JT EXT FX/ EXT FY/ EXT FZ/ EXT MX/ EXT MY/ EXT MZ/
INT FX INT FY INT FZ INT MX INT MY INT MZ
SUPPORT=1
1 0.00 -0.88 0.00 0.00 0.00 0.00
-0.15 -33.70 0.00 0.15 0.00 0.74 111111
FOR LOADING - 4
APPLIED JOINT EQUIVALENT LOADS
JOINT FORCE-X FORCE-Y FORCE-Z MOM-X MOM-Y MOM-Z
5 0.00000E+00-6.20171E-01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
6 0.00000E+00-1.31999E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
7 0.00000E+00-6.11357E+00 0.00000E+00 1.03050E+00 0.00000E+00 6.62705E-01
8 0.00000E+00-1.27599E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
9 0.00000E+00-1.20000E+00 0.00000E+00 0.00000E+00 0.00000E+00-2.00000E-01
10 0.00000E+00-1.61166E+00 0.00000E+00 0.00000E+00 0.00000E+00 2.00000E-01
11 0.00000E+00-7.42500E-01 0.00000E+00 0.00000E+00 0.00000E+00-1.48500E-01
12 0.00000E+00-4.49763E+00 0.00000E+00 0.00000E+00 0.00000E+00-2.25375E-01
21 0.00000E+00-9.71029E-01 0.00000E+00 0.00000E+00 0.00000E+00 1.82446E-01
22 0.00000E+00-2.00132E+00 0.00000E+00 0.00000E+00 0.00000E+00-7.81430E-02
23 0.00000E+00-1.54908E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
24 0.00000E+00-1.57560E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
25 0.00000E+00-3.39360E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
26 0.00000E+00-3.33648E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
27 0.00000E+00-2.03921E+00 0.00000E+00-4.46250E-02 0.00000E+00 0.00000E+00
28 0.00000E+00-1.26807E+00 0.00000E+00 0.00000E+00 0.00000E+00-2.05541E-01
29 0.00000E+00-1.84335E+00 0.00000E+00 4.46250E-02 0.00000E+00 0.00000E+00
30 0.00000E+00-1.21368E+00 0.00000E+00 9.90000E-02 0.00000E+00 0.00000E+00
31 0.00000E+00-1.26732E+00 0.00000E+00 0.00000E+00 0.00000E+00-1.46340E-01
32 0.00000E+00-2.38710E+00 0.00000E+00 0.00000E+00 0.00000E+00 1.46340E-01
34 0.00000E+00-2.54635E+00 0.00000E+00 3.50733E-02 0.00000E+00 0.00000E+00
35 0.00000E+00-1.51237E+00 0.00000E+00 0.00000E+00 0.00000E+00 2.54507E-01
36 0.00000E+00-3.06548E+00 0.00000E+00-4.10837E-03 0.00000E+00 0.00000E+00
37 0.00000E+00-1.24985E+00 0.00000E+00 0.00000E+00 0.00000E+00-1.44292E-01
38 0.00000E+00-9.71029E-01 0.00000E+00 0.00000E+00 0.00000E+00-1.82446E-01
39 0.00000E+00-3.16072E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
40 0.00000E+00-1.73880E+00 0.00000E+00 0.00000E+00 0.00000E+00-3.20728E-02
41 0.00000E+00-1.13619E+00 0.00000E+00 0.00000E+00 0.00000E+00 2.61823E-01
42 0.00000E+00-1.09831E+00 0.00000E+00 0.00000E+00 0.00000E+00 2.53096E-01
43 0.00000E+00-1.81800E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
44 0.00000E+00-1.78740E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
47 0.00000E+00-1.22040E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
48 0.00000E+00-1.42290E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
49 0.00000E+00-1.48500E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
50 0.00000E+00-6.95546E-01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
51 0.00000E+00-5.86203E-01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
52 0.00000E+00-6.68345E-01 0.00000E+00 0.00000E+00 0.00000E+00 1.54014E-01
46
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
X = 0.290195982E+01
Y = 0.484050204E+01
Z = 0.156505620E+01
STAAD SPACE -- PAGE NO. 25
47
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
JT EXT FX/ EXT FY/ EXT FZ/ EXT MX/ EXT MY/ EXT MZ/
INT FX INT FY INT FZ INT MX INT MY INT MZ
SUPPORT=1
1 0.00 0.00 0.00 0.00 0.00 0.00
0.21 -32.18 -0.11 0.20 0.00 0.73 111111
FOR LOADING - 5
APPLIED JOINT EQUIVALENT LOADS
JOINT FORCE-X FORCE-Y FORCE-Z MOM-X MOM-Y MOM-Z
17-2.64528E+01-1.20707E+02-4.74408E+01 0.00000E+00 4.26256E+01-6.96298E+01
18 2.64528E+01-1.20707E+02-4.74408E+01 0.00000E+00-4.26256E+01 6.96298E+01
19-2.64528E+01-1.20707E+02 4.74408E+01 0.00000E+00-4.26256E+01-6.96298E+01
20 2.64528E+01-1.20707E+02 4.74408E+01 0.00000E+00 4.26256E+01 6.96298E+01
21 0.00000E+00-2.54336E-01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
28 0.00000E+00-9.15000E-01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
29 0.00000E+00-1.57566E+00 0.00000E+00-3.26177E-01 0.00000E+00 0.00000E+00
30 0.00000E+00-1.57566E+00 0.00000E+00-3.26177E-01 0.00000E+00 0.00000E+00
STAAD SPACE -- PAGE NO. 26
48
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
X = 0.269666615E+01
Y = 0.982533378E+01
Z = 0.143170947E+01
JT EXT FX/ EXT FY/ EXT FZ/ EXT MX/ EXT MY/ EXT MZ/
INT FX INT FY INT FZ INT MX INT MY INT MZ
SUPPORT=1
1 0.00 0.00 0.00 0.00 0.00 0.00
-1.15 -133.45 -0.19 -0.09 0.00 1.02 111111
FOR LOADING - 6
APPLIED JOINT EQUIVALENT LOADS
49
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
JT EXT FX/ EXT FY/ EXT FZ/ EXT MX/ EXT MY/ EXT MZ/
INT FX INT FY INT FZ INT MX INT MY INT MZ
SUPPORT=1
FOR LOADING - 7
APPLIED JOINT EQUIVALENT LOADS
JOINT FORCE-X FORCE-Y FORCE-Z MOM-X MOM-Y MOM-Z
50
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
RY= 0.00000E+00 0
RZ= 0.00000E+00 0
JT EXT FX/ EXT FY/ EXT FZ/ EXT MX/ EXT MY/ EXT MZ/
INT FX INT FY INT FZ INT MX INT MY INT MZ
SUPPORT=1
FOR LOADING - 8
APPLIED JOINT EQUIVALENT LOADS
JOINT FORCE-X FORCE-Y FORCE-Z MOM-X MOM-Y MOM-Z
JT EXT FX/ EXT FY/ EXT FZ/ EXT MX/ EXT MY/ EXT MZ/
INT FX INT FY INT FZ INT MX INT MY INT MZ
SUPPORT=1
FOR LOADING - 9
APPLIED JOINT EQUIVALENT LOADS
JOINT FORCE-X FORCE-Y FORCE-Z MOM-X MOM-Y MOM-Z
51
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
JT EXT FX/ EXT FY/ EXT FZ/ EXT MX/ EXT MY/ EXT MZ/
INT FX INT FY INT FZ INT MX INT MY INT MZ
SUPPORT=1
FOR LOADING - 10
APPLIED JOINT EQUIVALENT LOADS
JOINT FORCE-X FORCE-Y FORCE-Z MOM-X MOM-Y MOM-Z
JT EXT FX/ EXT FY/ EXT FZ/ EXT MX/ EXT MY/ EXT MZ/
INT FX INT FY INT FZ INT MX INT MY INT MZ
SUPPORT=1
FOR LOADING - 11
APPLIED JOINT EQUIVALENT LOADS
JOINT FORCE-X FORCE-Y FORCE-Z MOM-X MOM-Y MOM-Z
52
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
JT EXT FX/ EXT FY/ EXT FZ/ EXT MX/ EXT MY/ EXT MZ/
INT FX INT FY INT FZ INT MX INT MY INT MZ
SUPPORT=1
LOADING- 3. 4.
FACTOR - 1.00 1.00
LOADING- 3. 4. 5.
FACTOR - 1.00 1.00 1.00
LOADING- 3. 4. 6.
FACTOR - 1.00 1.00 1.00
LOADING- 3. 4. 7.
FACTOR - 1.00 1.00 1.00
LOADING- 3. 5. 8.
FACTOR - 0.75 0.75 0.75
53
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
LOADING- 3. 5. 9.
FACTOR - 0.75 0.75 0.75
LOADING- 3. 5. 10.
FACTOR - 0.75 0.75 0.75
LOADING- 3. 5. 11.
FACTOR - 0.75 0.75 0.75
LOADING- 3. 6. 8.
FACTOR - 0.75 0.75 0.75
LOADING- 3. 6. 9.
FACTOR - 0.75 0.75 0.75
LOADING- 3. 6. 10.
FACTOR - 0.75 0.75 0.75
LOADING- 3. 6. 11.
FACTOR - 0.75 0.75 0.75
LOADING- 3. 4. 5. 8.
FACTOR - 0.75 0.75 0.75 0.75
LOADING- 3. 4. 5. 9.
FACTOR - 0.75 0.75 0.75 0.75
LOADING- 3. 4. 5. 10.
FACTOR - 0.75 0.75 0.75 0.75
LOADING- 3. 4. 5. 11.
FACTOR - 0.75 0.75 0.75 0.75
LOADING- 3. 4. 6. 8.
FACTOR - 0.75 0.75 0.75 0.75
54
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
LOADING- 3. 4. 6. 9.
FACTOR - 0.75 0.75 0.75 0.75
LOADING- 3. 4. 6. 10.
FACTOR - 0.75 0.75 0.75 0.75
LOADING- 3. 4. 6. 11.
FACTOR - 0.75 0.75 0.75 0.75
LOADING- 1. 3. 5.
FACTOR - 0.75 0.75 0.75
LOADING- 1. 3. 5.
FACTOR - -0.75 0.75 0.75
LOADING- 2. 3. 5.
FACTOR - 0.75 0.75 0.75
LOADING- 2. 3. 5.
FACTOR - -0.75 0.75 0.75
LOADING- 1. 3. 6.
FACTOR - 0.75 0.75 0.75
LOADING- 1. 3. 6.
FACTOR - -0.75 0.75 0.75
LOADING- 2. 3. 6.
FACTOR - 0.75 0.75 0.75
LOADING- 2. 3. 6.
FACTOR - -0.75 0.75 0.75
LOADING- 1. 3. 4. 5.
FACTOR - 0.75 0.75 0.38 0.75
55
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
LOADING- 1. 3. 4. 5.
FACTOR - -0.75 0.75 0.38 0.75
LOADING- 2. 3. 4. 5.
FACTOR - 0.75 0.75 0.38 0.75
LOADING- 2. 3. 4. 5.
FACTOR - -0.75 0.75 0.38 0.75
LOADING- 1. 3. 4. 6.
FACTOR - 0.75 0.75 0.38 0.75
LOADING- 1. 3. 4. 6.
FACTOR - -0.75 0.75 0.38 0.75
LOADING- 2. 3. 4. 6.
FACTOR - 0.75 0.75 0.38 0.75
LOADING- 2. 3. 4. 6.
FACTOR - -0.75 0.75 0.38 0.75
LOADING- 3. 4.
FACTOR - 1.00 1.00
LOADING- 3. 4. 5.
FACTOR - 1.00 1.00 1.00
LOADING- 3. 4. 6.
FACTOR - 1.00 1.00 1.00
LOADING- 3. 4. 7.
FACTOR - 1.00 1.00 1.00
LOADING- 3. 5. 8.
FACTOR - 1.00 1.00 1.00
LOADING- 3. 5. 9.
56
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
LOADING- 3. 5. 10.
FACTOR - 1.00 1.00 1.00
LOADING- 3. 5. 11.
FACTOR - 1.00 1.00 1.00
LOADING- 3. 6. 8.
FACTOR - 1.00 1.00 1.00
LOADING- 3. 6. 9.
FACTOR - 1.00 1.00 1.00
LOADING- 3. 6. 10.
FACTOR - 1.00 1.00 1.00
LOADING- 3. 6. 11.
FACTOR - 1.00 1.00 1.00
LOADING- 3. 4. 5. 8.
FACTOR - 1.00 1.00 1.00 1.00
LOADING- 3. 4. 5. 9.
FACTOR - 1.00 1.00 1.00 1.00
LOADING- 3. 4. 5. 10.
FACTOR - 1.00 1.00 1.00 1.00
LOADING- 3. 4. 5. 11.
FACTOR - 1.00 1.00 1.00 1.00
LOADING- 3. 4. 6. 8.
FACTOR - 1.00 1.00 1.00 1.00
57
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
LOADING- 3. 4. 6. 9.
FACTOR - 1.00 1.00 1.00 1.00
LOADING- 3. 4. 6. 10.
FACTOR - 1.00 1.00 1.00 1.00
LOADING- 3. 4. 6. 11.
FACTOR - 1.00 1.00 1.00 1.00
LOADING- 1. 3. 5.
FACTOR - 1.00 1.00 1.00
LOADING- 1. 3. 5.
FACTOR - -1.00 1.00 1.00
LOADING- 2. 3. 5.
FACTOR - 1.00 1.00 1.00
LOADING- 2. 3. 5.
FACTOR - -1.00 1.00 1.00
LOADING- 1. 3. 6.
FACTOR - 1.00 1.00 1.00
LOADING- 1. 3. 6.
FACTOR - -1.00 1.00 1.00
LOADING- 2. 3. 6.
FACTOR - 1.00 1.00 1.00
LOADING- 2. 3. 6.
FACTOR - -1.00 1.00 1.00
LOADING- 1. 3. 4. 5.
FACTOR - 1.00 1.00 0.50 1.00
LOADING- 1. 3. 4. 5.
58
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
LOADING- 2. 3. 4. 5.
FACTOR - 1.00 1.00 0.50 1.00
LOADING- 2. 3. 4. 5.
FACTOR - -1.00 1.00 0.50 1.00
LOADING- 1. 3. 4. 6.
FACTOR - 1.00 1.00 0.50 1.00
LOADING- 1. 3. 4. 6.
FACTOR - -1.00 1.00 0.50 1.00
LOADING- 2. 3. 4. 6.
FACTOR - 1.00 1.00 0.50 1.00
LOADING- 2. 3. 4. 6.
FACTOR - -1.00 1.00 0.50 1.00
59
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
60
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
1 ST MC250+180X12PL+50MMSPACE (UPT)
PASS IS-7.1.1(A) 0.592 1029
240.21 C -46.15 -0.13 0.00
2 ST MC250+180X12PL+50MMSPACE (UPT)
PASS IS-7.1.1(A) 0.592 1028
244.59 C 45.65 0.43 0.00
3 ST MC250+180X12PL+50MMSPACE (UPT)
PASS IS-7.1.1(A) 0.573 1029
214.64 C -45.17 1.17 0.00
4 ST MC250+180X12PL+50MMSPACE (UPT)
PASS IS-7.1.1(A) 0.577 1028
221.43 C 45.66 -0.27 0.00
* 5 ST ISMB200 (INDIAN SECTIONS)
FAIL IS-7.1.1(A) 1.040 1024
36.32 C -0.07 -25.68 1.04
6 ST ISMB150 (INDIAN SECTIONS)
PASS IS-7.1.1(A) 0.097 1034
16.21 C 0.01 -0.32 1.02
7 ST ISMB150 (INDIAN SECTIONS)
PASS IS-7.1.1(A) 0.089 1022
16.17 C 0.01 0.16 1.02
8 ST ISMB200 (INDIAN SECTIONS)
PASS 7.1.2 BEND C 0.898 1029
44.84 T 0.05 27.56 1.04
9 ST MC250+180X12PL+50MMSPACE (UPT)
PASS IS-7.1.1(A) 0.403 1029
199.68 C -29.59 0.03 0.00
STAAD SPACE -- PAGE NO. 44
10 ST MC250+180X12PL+50MMSPACE (UPT)
PASS IS-7.1.1(A) 0.422 1028
204.74 C 31.08 -0.33 0.00
11 ST MC250+180X12PL+50MMSPACE (UPT)
PASS IS-7.1.1(A) 0.380 1029
174.15 C -27.41 2.30 0.00
12 ST MC250+180X12PL+50MMSPACE (UPT)
PASS IS-7.1.1(A) 0.393 1028
189.83 C 28.35 1.34 0.00
* 13 ST ISMB200 (INDIAN SECTIONS)
FAIL IS-7.1.2 1.211 1029
63.13 T -0.10 36.76 1.00
* 14 ST ISMB200 (INDIAN SECTIONS)
FAIL 7.1.2 BEND C 1.096 1029
6.37 T -0.07 34.86 0.00
15 ST ISMB200 (INDIAN SECTIONS)
PASS IS-7.1.2 0.068 1035
21.41 T -0.03 -0.49 0.60
16 ST ISMB200 (INDIAN SECTIONS)
PASS IS-7.1.2 0.060 1035
21.07 T -0.02 -0.31 0.60
61
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
17 ST MC250+180X12PL+50MMSPACE (UPT)
PASS IS-7.1.1(A) 0.371 1029
151.55 C 29.10 0.48 2.40
18 ST MC250+180X12PL+50MMSPACE (UPT)
PASS IS-7.1.1(A) 0.378 1028
151.82 C -29.72 0.57 2.40
STAAD SPACE -- PAGE NO. 45
19 ST MC250+180X12PL+50MMSPACE (UPT)
PASS IS-7.1.1(A) 0.376 1029
152.02 C 29.68 -0.23 2.40
20 ST MC250+180X12PL+50MMSPACE (UPT)
PASS IS-7.1.1(A) 0.388 1028
152.42 C -30.81 -0.41 2.40
23 FR ISMC100 (INDIAN SECTIONS)
PASS IS-7.1.1(A) 0.074 1022
14.34 C 0.00 0.18 1.50
24 FR ISMC100 (INDIAN SECTIONS)
PASS IS-7.1.1(A) 0.074 1022
14.30 C 0.00 0.18 1.50
25 ST MC250+180X12PL+50MMSPACE (UPT)
PASS IS-7.1.1(A) 0.627 1021
147.55 C 52.09 0.00 1.50
26 ST MC250+180X12PL+50MMSPACE (UPT)
PASS IS-7.1.1(A) 0.630 1028
147.74 C -52.42 0.00 1.50
27 ST MC250+180X12PL+50MMSPACE (UPT)
PASS IS-7.1.1(A) 0.636 1021
147.93 C 52.99 0.00 1.50
28 ST MC250+180X12PL+50MMSPACE (UPT)
PASS IS-7.1.1(A) 0.643 1028
148.25 C -53.69 0.00 1.50
29 ST ISMB200 (INDIAN SECTIONS)
PASS 7.1.2 BEND C 0.982 1029
4.26 T 0.06 27.75 0.00
STAAD SPACE -- PAGE NO. 46
62
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
63
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
64
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
65
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
66
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
67
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
68
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
69
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
=======================================================================
70
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
71
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
72
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
73
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
74
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
75
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
STEEL TAKE-OFF
--------------
599. 208 TO 214 216 219 220 222 223 226 228 230 TO 236 239 241 243 TO 249 256 -
600. 259 260 290 298 300 TO 304 308 TO 317 322 327 TO 330
ST MC250+180X12PL+50MMS 39.19 36.287
ST ISMB200 34.97 8.273
ST ISMB150 59.42 8.719
FR ISMC100 16.79 3.148
ST ISMC75 30.33 2.120
SD ISA50X50X6 47.64 4.157
ST ISMC150 7.81 1.278
ST ISA50X50X6 45.89 2.003
SD ISA65X65X6 26.48 3.027
ST BUNKER 16.79 34.203
----------------
TOTAL = 103.216
601. ***************************************************************
602. *LOAD LIST 1000 TO 1035
603. *PARAMETER 2
604. *CODE INDIAN
605. *DFF 325 MEMB 5 TO 8 13 TO 16 23 24 29 TO 41 43 TO 52 54 TO 68 73 TO 102 105 -
606. *106 TO 164 204 208 216 226 228 230 239 241 243 256 259 260 290 298 -
607. *300 TO 303 309 TO 311 313 TO 317 322
608. *******-------------------------------------------EL. 3.5 METE
609. *DJ1 5 MEMB 5 29 46 56 314
610. *DJ2 6 MEMB 5 29 46 56 314
611. *DJ1 29 MEMB 39 41
612. *DJ2 30 MEMB 39 41
613. *DJ1 27 MEMB 37 259
614. *DJ2 34 MEMB 37 259
615. *DJ1 30 MEMB 43 44 313
616. *DJ2 32 MEMB 43 44 313
617. *DJ1 7 MEMB 8 30 50 54 60
618. *DJ2 8 MEMB 8 30 50 54 60
619. ****-------------------------------------------EL. 3.5 METE
620. *DJ1 5 MEMB 7 31 32 226
621. *DJ2 7 MEMB 7 31 32 226
622. *DJ1 21 MEMB 38 40 256
623. *DJ2 22 MEMB 38 40 256
624. *DJ1 33 MEMB 47 49 51
625. *DJ2 35 MEMB 47 49 51
626. *DJ1 31 MEMB 55 290
627. *DJ2 37 MEMB 55 290
628. *DJ1 38 MEMB 57 59 61
629. *DJ2 40 MEMB 57 59 61
630. *DJ1 6 MEMB 6 33 35 239
STAAD SPACE -- PAGE NO. 73
76
ANALYSIS AND DESIGN REPORT FOR HEATER AND BUNKER
SUPPORTING AND OPERATING PLATFORM STRUCTURE
77