Comment On (KIRBY - PEB PROPOSAL)
Developer's Consultants
Description Kirby Offering
Comments
0.5mm TCT Color Galvalume Kirby
Gable Sheeting (Kirby Wall) 0.5mm BMT is recommended
High Tensile profile
Galvalume Gutter & down take
pipes along both side walls. Thickness?? Colour Shall be
Eave Gutters & Down Spouts
as/Arch elevation
Primary Member Design & Deflection AISC (9th Edition) LRFD Design AISC- Shall also be matched as given
2016 in DBR
Primary Member Grade Spec ASTM A570 ASTM A572 written in DBR
ASTM A653M-04A written in
secondary Member Grade Spec ASTM A570
DBR
ASTM A792M written in DBR
Roof and side sheet Grade Spec ASTM A653
and should be PPGL
Members fabricated from hot rolled
ASTM A572 IS 2062 is written in DBR
structural shapes
Primary Bolts for field connection brand not specified "unbrako" preferrably be used
Note:- Apart from this some additional requirenments MUST be ensured/confirmed/added in PEB
Suppliers scope.
3D Analysis & Design of structure shall be performed in Staad-Pro software, Modelling all
1 the elements viz. rafter,purlins,bracing etc. in a single model and the same to be provided
us for review & approval along with GA Drawings.
All Connections as well as other miscc. Components design calculation shall be provided
2 us for review & approval in excel or some times in word format(clearly indicating the
reference taken for calculation) along with GA Drawings.