Building Class: A
Category: 1
Force, F = Cf x q x Ae
where: Force coefficient, Cf is dependent on solidity ratio and DVS
and Ae is the effective area of the frame normal to the wind direction
Tower:
column
Existing column
h (mm) = 1500
Existing
length of Corbel (mm) = 1018
(Pg 212)
Figure 5.1 (Reinforced
Concrete Analysis and ν / fcu = 0.07
Design by S.S Ray) z/d = 0.82
av / d = 0.48
z (mm) = 1197.20
Use 7 T20
As (mm2) = 2200 OK
Use 2-legged 8mm diameter links @ 200c/c for the upper 2/3 of d
2/3d = 973 mm
Use 10 T20
As (mm2) = 3140 OK
Sketch 300mm
300mm
Column takes 1/2 of the load transferred to beam from triangle & trapezium
h: Thickness of slab (mm) = 150
ρc : Density of Concrete (kN/m3) = 25
Slab weight (kN/m2) = 3.75
From Wind Calc Moment induced due to wind load (kNm) = 513.57