IL3AMF25

TB2:1 00
17
TB3 Custom termina Common terminal

REMOTE
PRESS Genset TB1
TB1:3 Oil Pressure 11
21 OIL TB1:1 TB1:6 1 17 TAu:S1 0 1 IL3AMF25:28
0
G 28 U N1 ABB-ATS:33 2 - TB2:10 TAu:S2 101 2 IL3AMF25:29
TEMP.
TB1:4 water Temp. 12
20 TEMP IL3AMF25:21 11 3 PRESS:G
G

Genset Current
FUEL 101 TB1:2 IL3AMF25:20 12 4 TEMP.:G
TB1:5 Fuel Level 13
19 FUEL
29 IL3AMF25:19 13 5 FUEL:Y
B Y TB3:1 17 6 IL3AMF25:49
KA6 ESB1:12 19A 7 ESB2:11
Preheat 30
1 87 30 IL3AMF25:46 21 8 PRESS:WK
IL3AMF25:47 22 9 TEMP.:WK
BAT SWITCH BATTERY
TB2:7 + TB2:6 FU1 26 Level:B 23 10 IL3AMF25:48
+
1
2 1 TB2 Double-deck terminal
U1 FU4
M SS 36 IL3AMF25:17
FU2 2 1 1 00

Genset Voltage
38 TB2:7
3 1
KA1 2 37 IL3AMF25:35
27 2 N1
28 TB2:4 KA1
2 SS 6 87 30 TB2:8 1 IL3AMF25:39
04 Start 38 3 N2
85 86

IL3 AMF25 CONTROLLER


KA8 KA2 Charger:N
1 0 87A 30 TB2:2
KA2 KA2 35 KA2:30 FU2:2
TB2:529 4 27
TB2:4 TB2:8 2
05 Fuel FU5 KA1:30
E FCS B 87 30 85 86 R1 R KA5:7 FCS:B
40 5 29
2 1

Mains Voltage
KA3 KA2:87 Regulator:Y
R
Regulator TB2:8 6
06 GCB 41 FU1:2 + KA6:30
B 8 7 6
Y 2X63A FU2:1 FU3:2
SB- SB+ KA4 42 SS:1
7
G TB2:9 7 Regulator:R

A0
8 7 07 MCB TB2:3
G N2 KA3:8 KA1:85
E + 39 L1 N1 8 -
KA6 KA2:85
TB2:9 9 IL3AMF25:- KA6:85
C Level A 08 Pre-start 9
85 86 211 FU7 ESB2:12 KA4:8
B 2 1 ABB-ATS:13 Charger:-
TB1:10 Water Level 23 9 10 10
48 Level:C TB3:2
TB2:9 - KA7 KA7 ABB-ATS IL3AMF25:+ 26 FU1 + TB2:6
-
101 U II-N
ESB2 ESB1 1 2 TB2:6 + FU2 27 TB2:4

L 1-N
TB1:7 19A 19
45 102
12 11 12 11 D2:2 80 FU3 + TB2:6
PRESS TB1:8 Oil Pressure 21
FU4 U1 IL3AMF25:36
WK 46 U
TEMP. TB1:9 Water Temp. 34 FU5

COM
22 FU6:1 R R1 IL3AMF25:40

COM
47 KA4

TAu
WK
TB2:10 35 L01 FU7
Remote Start A ABB-ATS:U L1 211 KA7:9

S1

S2

TB3:1 TB1:6

I
TB3:2 17 3 5

Load
49 KA4 34A KA3 36 FU5:1,FU8:1 R FU6 R2 KA5:6
ABB-ATS MCB FEEDBACK N3

0
2 6 2KA3 6

0
24 N
33 34 43 33 FU6:1,MCB:1 R FU8 222 KA7:13

II

3 5
13 14 GCB FEEDBACK 25
44

1 7

PE
KA7 KA7
D2 Charger R I-N
TB2:6 + FU3 80 81 KA5 82 R3 KA5 R2 FU6 R 5 3
+ L 2
CHARGER

2 12 11 5 62 1 FU8
13 222
TB2:10 2 1
- N2 TB2:3 KA7 R N2
- N
KA5 14
TB2:5 29
KA8 MCB NAME DENOTATION NAME DENOTATION NAME
7 8 Water Heater 83 R4 R DENOTATION
2 1 4 2 2 1 A Current Meter SS Starter Contactor TB1 Terminals
V Voltage Meter KA1,KA2 40A DC Relay TB2 Double-deck terminal
KA8 2X63A CT1…CT3 Current Transformer KA3...KA6 10A DC Relay TB3 Customer Terminals
Space Heater Emergency Switch MCCB Breaker
84 ESB1…ESB2
2 1 8 6 Starter
R1 N3 M
G Charge Motor
N2
Mains

Generadores

Gamma