CHECK LIST FOR THE REVIEW OF WELDER QULIFICATION RECORDS AS PER SECTON IX ,2001 EDITION

SL.NO. Parameter Acceptance criteria

Verify the following minimum


information on WQT
 Project Contractor shall indicate these in formations on Welder certification record
 Contract number
1  Applicable fabrication code and
QP specifications
 Welder ID number
 Date of certification

2 Verify essential variables. As per QW-350 or QW-360 as applicable(attached).


RT report if qualified by NDT(Acceptance as per ASME Sec.IX) or test reports if
3 NDT/Mechanical tests
qualified by Mechanical test as per QW-452.1.
4 Range of qualification. Thickness range as per QW-452.1 and diameter range as per 452.3