Load Setting

◆ Load Sensor type

Data
Parameter Parameter
1EA(PTM) 2EA(PTM) ”F164”

F164 7 9

110%

+ 7

PTM1

110%

+ + 9

PTM1 PTM2
Load Setting

◆ Analog Input port

SM 02/I PCB (Car Top)

JP9.1 +5V
JP9.2 AN1 weight signal input 1 (PTM1)
JP9.3 AN2 weight signal input 2 (PTM2)
JP9.4 0V
Load Setting

◆ Connection

PTM2 No Load : 3.9V


Full Load : 2.6V

PTM1 No Load : 3.9V


Full Load : 2.6V

PTM1

PTM2 Car Top


Load Setting

◆ Installation

Ä« ¹Ù´Ú
Car Bottom

Cushion
¹æÁø°í¹«
rubber
L L= about 15mm

½ºÅ©·ç
screw
60mm

BASE
Load Setting

◆ Setting (Connecting SVC Tool)

SM 02/G PCB (COP) Main Board

or
Load Setting

◆ Setting (No-Load)
If F41 is set as 1, no-load self-learning will be done. If the self-learning is successful,
F41 will be changed into 0
If no-load self-learning done. Self-learning result was saved in F48

E E

E E

 Value becomes
E 150~200 after zero load
setting

Success No Load Point save


Load Setting

◆ Setting (Full-Load)
If F41 is set as 2, Full-load self-learning will be done. If the self-learning is successful,
F41 will be changed into 0
If Full-load self-learning done. Self-learning result was saved in F49

E E

E E
2

 Value becomes
300~400 after full
E
320 load setting
F49

Success Full Load Point save


Overload (110%)

◆ Micro Switch (110%)

Car Top PCB

110% Switch