Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Equipment - Component Site/Vessel Name - Code Customer

Gas Generator E-14 - Engine - Stationary Gas Gas Engine- Ashugonj Power Station Co. Limited - 26482 Ashugonj Power Station Co. Limited
E-14

Manufacturer - Model LubeAnalyst Code Registered Lubricant


INNIO Jenbacher GmbH & Co OHG - JGS 620 F 01385208/EGN01 Shell - Mysella S5 N 40

Diagnosis
The Sample test results all indicate that the equipment and lubricant are both performing within normal working limits with no indication of
abnormal wear or equipment stress. Please continue operating your equipment as normal.
Normal

Sample Information
Sample Number 132319 132362 133251 1318150 1305630

Sample Condition

Sample Date 09/Mar/2020 01/Feb/2020 22/Dec/2019 07/Sep/2019 08/Aug/2019


Sample Received 13/Mar/2020 06/Feb/2020 26/Dec/2019 11/Sep/2019 22/Aug/2019
Sample Completed 18/Mar/2020 12/Feb/2020 30/Dec/2019 16/Sep/2019 27/Aug/2019
Lubricant in use Mysella S5 N 40 Mysella S5 N 40 Mysella S5 N 40 Mysella S5 N 40 Mysella S5 N 40
Equipment Life 54208 (Hours) 53636 (Hours) 52981 (Hours) 50835 (Hours) 50135 (Hours)
Lubricant Life 17 (Hours) 613 (Hours) 869 (Hours) 539 (Hours) 781 (Hours)
Top-up Volume
Physical Characteristics
Viscosity 100°C cSt 13.43 14.54 14.80 14.21 14.61
TBN (D 2896) mg KOH/g 4.28 3.90 3.00 3.91 3.06
TAN (D 664) mg KOH/g 0.91 1.99 2.15 1.53 1.69
Wear
Iron (Fe) ppm 1 3 4 5 6
Chromium (Cr) ppm 0 0 0 0 1
Tin (Sn) ppm 0 1 0 1 0
Lead (Pb) ppm 0 1 1 1 1
Copper (Cu) ppm 0 0 0 0 0
Nickel (Ni) ppm 0 0 0 0 0
Aluminium (Al) ppm 1 1 1 2 1
Vanadium (V) ppm 0 0 0 1 0
Silver (Ag) ppm 0 0 0 0 0
Titanium (Ti) ppm 0 0 0 0 0
Contamination
Water (FT-IR) % <0.05 <0.05 <0.05 <0.05 <0.05
Glycol (FT-IR) % 0.0 0.0 0.0 0.0 0.0
Sodium (Na) ppm 1 1 3 9 3
Silicon (Si) ppm 3 1 0 1 0
Potassium (K) ppm 1 1 2 0 0
Chlorine Content IP 244 % W/W 0.001 0.0 0.0 0 0.0
Soot (FT-IR) Abs/0.1mm 0.0 0.0 0.0 0.0 0.0
Additives
Calcium (Ca) ppm 1332 1590 1420 2456 1588
Zinc (Zn) ppm 296 380 310 409 356
Phosphorus (P) ppm 251 299 254 325 285
Barium (Ba) ppm 0 0 0 0 0
Molybdenum (Mo) ppm 0 0 0 0 0
Magnesium (Mg) ppm 4 5 5 9 6
Boron (B) ppm 0 0 0 0 0
Oil Condition
Oxidation (FT-IR) Abs/0.1mm 11.96 16.60 18.99 15.79 16.78
Nitration (FT-IR) Abs/0.1mm 4.00 6.55 7.0 6.3 6.6

All advice is given in good faith and assumes that the sample fully represents the indicated oil charge. Any recommended values refer to normal ranges. For all queries, please remember to quote your
Sample Number(s). Once printed, this document is un-controlled. For current versions, authorised users should refer to Shell LubeAnalyst online at www.lubeanalyst.shell.com. This report is provided
subject to the general Shell LubeAnalyst Terms and Conditions available at www.lubeanalyst.shell.com.

01 / 02 Ashugonj Power Station Co. Limited - 26482


Graphs

Physical Characteristics Wear


15.1 5 7
14.8 6
4 5

mg KOH/g
14.5
4

ppm
cSt

14.2 3
3
14 2
2
13.7 1
1 0
03/08/19
25/08/19
16/09/19
08/10/19
30/10/19
21/11/19
13/12/19
04/01/20
26/01/20
17/02/20
10/03/20

03/08/19

25/08/19

16/09/19

08/10/19

30/10/19

21/11/19

13/12/19

04/01/20

26/01/20

17/02/20

10/03/20
Date drawn Date drawn

Viscosity 100°C (cSt) TBN (D 2896) (mg KOH/g) Iron (Fe) (ppm) Chromium (Cr) (ppm) Tin (Sn) (ppm)
TAN (D 664) (mg KOH/g) Lead (Pb) (ppm) Copper (Cu) (ppm) Aluminium (Al) (ppm)
Silver (Ag) (ppm)

Contamination Additives
10 2946
8 2455
1964
6
ppm

ppm
%

1473
4
982
2 491
0 0 0
03/08/19

25/08/19

16/09/19

08/10/19

30/10/19

21/11/19

13/12/19

04/01/20

26/01/20

17/02/20

10/03/20

03/08/19

25/08/19

16/09/19

08/10/19

30/10/19

21/11/19

13/12/19

04/01/20

26/01/20

17/02/20

10/03/20
Date drawn Date drawn

Sodium (Na) (ppm) Silicon (Si) (ppm) Glycol (FT-IR) (%) Calcium (Ca) (ppm) Zinc (Zn) (ppm) Phosphorus (P) (ppm)
Barium (Ba) (ppm) Molybdenum (Mo) (ppm)
Magnesium (Mg) (ppm) Boron (B) (ppm)

Oil Condition
21
18
Abs/0.1mm

15
12
9
6
03/08/19

25/08/19

16/09/19

08/10/19

30/10/19

21/11/19

13/12/19

04/01/20

26/01/20

17/02/20

10/03/20

Date drawn

Oxidation (FT-IR) (Abs/0.1mm)


Nitration (FT-IR) (Abs/0.1mm)

All advice is given in good faith and assumes that the sample fully represents the indicated oil charge. Any recommended values refer to normal ranges. For all queries, please remember to quote your
Sample Number(s). Once printed, this document is un-controlled. For current versions, authorised users should refer to Shell LubeAnalyst online at www.lubeanalyst.shell.com. This report is provided
subject to the general Shell LubeAnalyst Terms and Conditions available at www.lubeanalyst.shell.com.

02 / 02 Ashugonj Power Station Co. Limited - 26482

You might also like