Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

TECHNICAL DATA SHEET

LPI® Data Transmission Protectors: RS range

Features
 Pin surge protector
 High performance surge protector for computers, terminals,
printers and other peripheral equipment
 Moulded construction
 Low clamping voltage
 Surge life: > 1000 impulses
 Peak surge current of 50 A for a 10/100 s waveshape and 400 A
for 8/20 s waveshape, for RS422 25-25 Pin

Technical Data
Ordering code: RS232-9-9 Pin RS232-25-9 Pin RS232-25-25 Pin RS422-25-25 Pin
2,3,4,5,6,8,9,10,14,1
All pins to SGND 2,3,4,5,6,8,20,22 to All pins to SGND 5,16,17,18,20,21,22
Pins connected (Pin 5) SGND (Pin 7) (Pin 7) to SGND (Pins 7 &
through: SGND to Ground SGND to Ground SGND to Ground 19)
(Case) (Pin 1/Case) (Pin 1/Case) SGND to Ground
(Pin 1)
All other pins All other pins
Pins not connected: connected through connected through
but not protected but not protected

Peak signal voltage


(Protected Pins to ± 18 V ±9V
Ground):

DC break-down
22 V ± @ 1 mA 15 V ± @ 1 mA
voltage:
Max. Leakage
current (Pin to ≤ 5 µA @ 18 V ≤ 5 µA @ 18 V
Ground):

Peak surge current: 50 A with 10/1000 s waveshape 400 A with 8/20 s waveshape

Surge life: > 1000 impulses (0.5/100 kHz, 6000 V Ring wave, ANSI / IEEE C62.41 Cat. A)

Operating
temperature range - 40°C ~ + 60°C / 0 – 95%
(T) / Humidity:

Warranty: 5 years - Contact LPI for full warranty details

Weight: 47 g 66 g 66 g 66 g

Commercial in Confidence Document ID: LPIDOC-26-3361 Version: 1.0 04/11/2017 Page 1


Copyright © 2017 LPI
TECHNICAL DATA SHEET

Application
Ordering code: RS232-9-9 Pin RS232-25-9 Pin RS232-25-25 Pin RS422-25-25 Pin
Application: RS232 RS-232 RS-422
RS-232C
(EIA/TIA 574) Null Modem (EIA/TIA 530)
Male/Female, DB25
Male/Female, DB9 Male/Female, DB25 Male/Female, DB25

Signal Attenuation
RS 232 range RS422-25-25
Termination, 3 k, 2.2 nF Termination, 3 k, 78 pF
(External Shunt Capacitance) (External Shunt Capacitance)
< 0.1 dB to 2 Mbits/sec < 0.1 dB to 2 Mbits/sec
< 1.0 dB to 4 Mbits/sec < 1.0 dB to 4 Mbits/sec
< 3.0 dB to 5.5 Mbits/sec < 3.0 dB to 5.5 Mbits/sec

SGND
(Signal Ground)

Figure 1: Schematic Diagram of RS Protector

Installation / Operating instructions


This surge protector is used for the protection of data and signal lines. The protective device must be
fitted directly to the equipment to be protected.

Important
The retainers must always be securely fastened to the equipment. No flying earth lead required.

Commercial in Confidence Document ID: LPIDOC-26-3361 Version: 1.0 04/11/2017 Page 2


Copyright © 2017 LPI

You might also like