Orifice and Jet Trajectory
Orifice and Jet Trajectory
Fluid Test
Machine parts:
1-clamp 2- scale (h)
3-Head Tank 4-Inlet Pipe
5-Orifice Plate 6-Adjustable feet
7-Adjustable Overflow pipe 8-Needle
9-Clip Board
Procedure :
o Connect apparatus to the water supply of
the hydraulic bench and start the pump.
o Adjust the water head h by means of the
adjustable overflow.
o Adjust the trajectory probes of the
trajectory tracing device until they get in
contact with the jet. note them
o Read off the measured y-positions of the
jet and down in tabular form (sample
worksheet shown below).
o Useing a stopwatch establish the time t
required for collecting certain volume Vol
of water in the collecting tank.
o Repeat the procedure for other values of
the water head h.
Calculation:
Water head h (m) Collected water Time (s)
volume
0.265 cm 0.00155 m³ 16.26 s
Orifice diameter Orifice area Qact
8 mm 0.00005024 m² 9.532 × 𝟏𝟎−𝟓 (m³/s)