ANCHORED Sheet Pile Wall

You might also like

Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 11

BS8002 - anchored

ANCHORED Sheet pile wall BS8002: 1994

phi = 30.00 º
gamma = 20.00 kN/m3 Min exc = 0.4
h= 5.00 m Design phi = 25.7
M= 1.20
a= 1.00 m
Surcharge = 10.00 kPa Ka = 0.395
Kp = 2.531

Enter values into fields above, then click Solve.

FORCES:
Pp = 210.05 kN
Pa = 270.96 kN
Pq = 32.72 kN

Design Results:
LEVER ARM:
lp = 6.32 m
la = 4.52 m Design depth (d+min exc
lq = 3.14 m

MOMENTS:
Mp = 1327.67 kNm
Ma = 1224.91 kNm
Mq = 102.76 kNm

CHECK (ΣM=0)
Mp - Ma - Mq = 0.0000

Page 1
BS8002 - anchored

surcharge, q

a
m
º
h
Pq

min exc
Pa

Pp d

Design Results:

d= 2.88 m
esign depth (d+min exc) = 3.28 m

Page 2
BS8002 - anchored

-335544

Page 3
Eurocode 7, DA1, C1 - anchored

ANCHORED Sheet pile wall Eurocode 7 - GEO limit state, Design Approach 1 - Combination

phi = 30.00 º Min exc =


gamma = 20.00 kN/m3 Design phi =
h= 5.00 m Design gamma =

a= 1.00 m
Surcharge = 0.00 kPa Ka =
Kp =

Enter values into fields above, then click Solve.

Actions: (Rep.) (Design)

FORCES (kN):
Pp = 127.85 172.59
Pa = 185.72 250.72
Pq = 0.00 0.00

Design effect of actions (rotation of wall):


LEVER ARM: Design depth (d+min exc) =
lp = 5.78 m
la = 3.98 m
lq = 2.73 m

MOMENTS:
Mp = 996.94 kNm
Ma = 996.94 kNm
Mq = 0.00 kNm

CHECK (ΣM=0)
Mp - Ma - Mq = 0.0001

Page 4
Eurocode 7, DA1, C1 - anchored

, Design Approach 1 - Combination 1

Partial factors
0.4 m
30.0 º On unfavourable actions/action effects
20 kN/m3 Permanent action γG = 1.35
Variable actions γQ
= 1.50

0.333 On material properties/resistances


3.000 Coef. of shearing γφ = 1.00
Weight density γ γ
= 1.00

Design Results:

d= 2.06 m
esign depth (d+min exc) = 2.46 m

Page 5
Eurocode 7, DA1, C1 - anchored

-335544

Page 6
Eurocode 7, DA1, C1 - anchored

surcharge, q

h
Pq

min exc
Pa

Pp d

Page 7
Eurocode 7, DA1, C2 - anchored

ANCHORED Sheet pile wall Eurocode 7 - GEO limit state, Design Approach 1 - Combination

phi = 30.00 º Min exc =


gamma = 20.00 kN/m3 Design phi =
h= 5.00 m Design gamma =

a= 1.00 m
Surcharge = 0.00 kPa Ka =
Kp =

Enter values into fields above, then click Solve.

Actions: (Rep.) (Design)

FORCES (kN):
Pp = 199.16 199.16
Pa = 278.77 278.77
Pq = 0.00 0.00

Design effect of actions (rotation of wall):


LEVER ARM: Design depth (d+min exc) =
lp = 6.30 m
la = 4.50 m
lq = 3.13 m

MOMENTS:
Mp = 1255.30 kNm
Ma = 1255.30 kNm
Mq = 0.00 kNm

CHECK (ΣM=0)
Mp - Ma - Mq = 0.0000

Page 8
Eurocode 7, DA1, C2 - anchored

, Design Approach 1 - Combination 2

Partial factors
0.4 m
24.8 º On unfavourable actions/action effects
20 kN/m3 Permanent action γG = 1.00
Variable actions γQ
= 1.30

0.409 On material properties/resistances


2.444 Coef. of shearing γφ = 1.25
Weight density γ γ
= 1.00

Design Results:

d= 2.85 m
esign depth (d+min exc) = 3.25 m

Page 9
Eurocode 7, DA1, C2 - anchored

-335544

Page 10
Eurocode 7, DA1, C2 - anchored

surcharge, q

h
Pq

min exc
Pa

Pp d

Page 11

You might also like