Nominal spacing of links to be 0.7Sd or 12 x 4 diameter of compression bor, which Curtailment bors given by simplified rules in 6.2.7 unless otherwise specified ———| jever is less. BEAMS MB1 Span and support details. Nominal cover to all reinforcement Specified by designer (Normally 40mm; see 6.2.2) Tension lap unless otherwise specified. Area of U’ bars equal to that for support moment or 50% of maximum spon area (50% for simple supports), whichever is greater. For moment connection between deom ond edge columns see 6.2.10 Bors specified by designer. For beam depth of 750 or more use minimum of T16's ot 250. For sections with more than one. layer of main bars spacers are provided. Diameter 25 or mein bar diometer whichever is greoler, Cover should be greater thon: equivalent bar size. MB1.DWG Cy 50 q 50 L I | [i 25 25 4 8 Curtailment of bottom bers given by simplified rules in 6.2.7 unless otherwise specified Tension lap unless otherwise specified. ‘Closer’ bars used with open links for beam width of 300 or more, Hanger bars to be 20% of maximum support area unless otherwise specified. For beams 500 deep or more use minimum 2 T16's, One space should be left (75mm) sufficient to insert poker vibrator. Main top bars ploced inside hanger bars. Ove Arup Partnership Botiom support splice bars placed inside main bars. Areo at least 30% of maximum spon area Special care should be given to avoid congestion of reinforcement especially at laps. Morch 2006 BEAMS MB2 Broad shallow sections. For general details see Model Detail MBI The longitudinal space token by eoch set of links shown is 3 x bar size, This should be checked to ensure congestion does not occur. At external supports the ‘anchorage of longitudinal bars should be treated as for slabs. See Model cetail MS2. Greater of 109. or 70 75. minimum "Closer’ bar for overall ink. (This may not be required where the slab reinforcement 's coincident with links.) Greater of 58 or 50 Internal links should not overlap, Moximum lateral soacing of ine legs is effective beam depth The distonce of @ tension bor from a verical leq should nat be greater thon 150. MB2.DWG Ove Arup Partnership Morch 2006 At least 50% of maximum ares continues to end of cantilever unless specified otherwise by designer. ——— BEAMS MB3 Cantilever beams For general details see Model Details MBI. Curtailment of main cantilever bors os specified by designer. ‘At least 50% of cantilever bors should be anchored a distance of 1.5 x cantilever. No reinforcement should be stopped less than 0.75 x cantilever unless specified by designer. 50. Tension lop for 'U" bar. Bottom bars specified by designer. Minimum 2 T16's. MB3.DWG 25. Ove Arup Partnership Morch 2006 This detail allows bors to be extended easily to give foundation level tolerance. Spacing of links at lap not greater than: = 126 of longitudinal bar = 0.6 x lesser dimension of column = 240 At least 3 No. links Top of foundetion MC1.DWG COLUMNS MC1 Bottom detail. Nom. cover to all reinforcement Specified by designer (Normally 40mm; see 4.2.2) Compression lap plus 150 for foundation level tolerance, Kicker: 75 450 (150 below ground) Ove Arup Partnership March 2006 Projection above slab level: Compression lap + kicker height — unless specified otherwise. Nominal floor level COLUMNS MC2 intermediate detail. This detail is used where column is concentric and of the some ‘ dimensions as the storey below, dedi! Nom. cover to all reinforcement wn Specified by designer Weds (Normally 40mm; see 4.2.2) ri ft ita tl WL Hy ‘Additional links may be required. MI See 4.2.8 ete Slab or beam soffit: No special link at crank, Spacing of links ot lop not greater than: = 12¢ of longitudinal bar = 06 x lesser dimension of column = 240 ‘At least 3 No, links Nominal floor level Lorger dimension of column Pitch of links not greater than ~ 12g of longitudinal bor JAA = 06 x lesser dim. of column - 240 Vr av At least 3 No. links Link at knuckle of crank, - Cronk at bottom of lift Length of crank is 10 x offset 50 to stort to link run. Main bors rest on kicker. MC2.DWG 7 Kicker: 75 Denotes direction of crank. F-Link not required for face bar if y it fs within 150 of restrained bor. 4124 minimum A-A Ove Arup Partnership March 2006 COLUMNS MC3 Intermediate detail This detail opplies for stepped or offset columns. See MC2 for general notes. Spacing of links et lap not Where columns cre offset or lorge moments exist these bars, should be anchored into floor slao as shown. Nominal floor level ve yy | greater than: = 12¢ of longitudinal bar 0.6 x lesser dim. of column = 240 At least 3 No. links f min, Slab or beam soffit: Splice bars are located by Additional links may be required. See 4.28 L Fixing dimension to be ‘compression lop +75 unless specified, dimensions from foce of lower column, Locating links. Minimum 3 sets. MCS.0WG Ove Arup Partnership March 2006 COLUMNS MC4 Top detail Detail ‘A’ applies when slab depth is not less than: 200 20 size of column bors 250 25 size of column bars 300 using $2 size of column bars otherwise Detail ‘3° applies. Nominal roof level: For single storey buildings or where splice bors have been used Slab or beam soffit Tl ct the floor below see MCS. For general details see Model Detail MC2 Tension lop For edge & corner columns tension lops should equal 4.4 x anchorage length for 25mm diameter bars and Spacing of links at lap not greater than: = 126 of longitudinal bar over, unless otherwise specified. = = 0.6 x lesser dim. of colurnn = 240 At least 3 No. links —= =r PLAN DETAIL Column bars ore positioned in. level from nominal roof level. Spacing of links ot lop not greater then: | }——— Tension lop = 129 of longitudinal ber For edge & corner columns = 0.6 x lesser dim. of column tension laps should equal = 240 1.4 x anchorage length for A least 3 No. links 25mm diameter bars and over, unless otherwise specified. Bors must be positioned to: avoid clashes. a) PLAN DETAIL 'B’ Mc4.owG Ove Arup Partnership March 2006 COLUMNS MC5 Top detail This detoil is used for single storey buildings and where splice bars have been used at the floor below. For general detcils see Model Detail MC2. Level of top bar depends op accuracy of vertical leg length and height of kicker Nominal roof level Slab or beom soffit = These bars should be turned as shown in Model Oetoil MC4 8 in accordance with the table given in MCA Spacing of Hinks at top not be greater than | iF =" 12¢ of longitudinal bar H = 06 x lesser dim. of column th ~ 240 H Ii — Kicker: At least 3. No. links Ha Kicker: 78 it ni Aig nat font | Haas For detail of splice see MC3. MC5.DWG Ove Arup Partnership March 2006 Helical binders scheduled in 12m. lengths, Tension lop length is required between helice! binders. MCB.DWG COLUMNS MC6 Cireuler columns. For general delails see Model Detail MC2. Helical binders are used unless circular links are specified by designer. Main bars scheduled straight. Cage is rotaled to lap with cage below, pepitch of helix 0.59 Kicker: 75 Ove Arup Partnership March 2006 Two column links should be placed close to corbel top. CORBELS MCB1 Without welds. This detell is suitable when using 16mm bar size or smaller for the main tensile reinforcement. Nominal cover: Specified by designer, Distance between edge of bearing ond inside of bor to be © minimum of the bar diameter or 0.75 x cover, whichever is greater. Tension lap Main tensile reinforcement. Large radius. of bend is required, Secondary horizontal reinforcement. Total ‘area of this should not be less than 0.50 of area of moin tensile reinforcement. Compression owe Compression bars. Total creo of this should not be less thon 1000mmi/metre width of corbel Outer compression bors angled to poss inside links. (FTN iS MCB1.DWG. A-A Ove Arup Partnership March 2006 Two column links should be. placed close to corbel top. Large radius of bend required. CORBELS MCB2 With welds. This detcil is suitable when using 20mm bar size or greater for the main tensile reinforcement, Nominal cover: Specified by designer. Distance between edge of beoring and outside of plate or bar should not be less than the vertical cover to the plate or bar. Kein tensile bors welded to o cross bor, or plate, ond to the vertical compression bars. Tension lap compression coum Horizontal links. Total ‘rea should not be less than 0.50 of area of the main tensile reinforcement. Compression bars. Tote! areo of which should not be less then 1000mmi/metre width of corbel MCB2.DWG A-A Ove Arup Partnership March 2006 HALF JOINTS MHJ Note:— ‘Special design information must be given concerning the bearing peds. Nominal eover:— Specified oy designer. (Normaly to ensure 40mm to the mein steel: see 9.2.2). Full length Finks sufficient to resist totel reaction equally spaced Tension anchorage hy | A : =p A i oi i Ca | ‘ be i a sc b Ne Distance between edge of bearing “ ard inside of bor to be a minimum 4 of the bar dlameter or 0.75 x Ae over, whichever is. greater, : 1 Horizontal 'U' bar to be the some. digmeter os main bottom bors Nominal hanger links et 450. Cranked bars if necessory for crack control. Tension lap for cranked bar. Horizontel 'U' bor with standard Tension lap radius of bend. Nominal links ot 150. A-A MHJLOWG Ove Arup Partnership March 2006 Tension anchorage length if "U'— bars ore used. NIBS MN 1 This detail is suitable for half joints in slabs. Minimum nominal overlap of reinforcement in nib and reinforcement in_supported member to be 60. Nominal cover:— Specified by designer. Links to be specified by designer to toke load on nib. Closed links or 'U’ bors may be used, Not less thon ber diameter or 0.75 x nominal cover, whichever is greater. MN1.OWG Ove Arup Portnership LDiometer of links to be not more thon 12 March 2006 Tension anchorage length pA NIBS MN2 Shallow nibs suitable for supporting brickwork. Nominal cover:— Specified by designer. y—Links to be specified by designer to take lood on nib. [Horizontal "U' bars. Diameter to be not more than 16. Av € 36 Wired to at least two main longitudinal bars. “depth of nib to be nat less than 140. See also 9.2.7.3 for strut & tie model Lacer bor to be some diometer os U" bors. if (D if [o MN2.DWG Ove Arup Partnership “pitch of ‘U’ bars to be not more than 250, Moreh 2006 PAD FOOTINGS MF 1 For details of column splice see MCT Compression lop plus 150 for foundation level tolerance. Kicker: 75 (180 below ground) Footing level vp Unless specified bs, by design, use Sulticient cover —+ 110-300 (3 No. min.) to ensure no 450 } problems of fit 1 min. 4 \ A Tis Main bars normally straight, — Bors may be bobbed if required by design. MF1.DWG Ove Arup Partnership March 2006 Cover to starter bars is PILE CAPS MF2 For deteil of column splice see Net specified from column faces. Compression lap plus 150 for foundation level tolerance. Kicker: 75 (150 below ground) Pile cap level Sufficient cover to ensure. no problems of fit, 450 min, Length of bob specified by design, 2 layers of Iecers, 112, Tr00 The main bars are bent: at both ends. Bors normally rest on top of piles ~ bottom cover allows for this. MF2.0G Ls Ove Arup Partnership \-if large radius of bend specified corner bar shifted accordingly. Unless specified by design use T10=S00 (3 No. min.) March 2006 [40 for exposed concrete. 50 for buried concrete, |, Foundation level FOUNDATIONS MF3 Multi-column base For details of column storter bors see Model Detoil MF For details of column splice see Model Detail MCI {300 min. overlap. Distribution bors TI6's at 300 centres, Two layers of lacers, T12's. MFS3.0NG bs 5 300 min, overlap. Ove Arup Partnership March 2006 FOUNDATIONS MF4 Ground slab and beam. For retcining wall details see Mode! Detoils MRWT or MRWZ [40 for exposed concrete 50 for buried concrete. [—Mesh fabric — A193 unless specified otherwise. Tension lop 7 {________ Extension to link not required if width of link is 300 or more. MF4.0NG Ove Arup Partnership March 2006 FOUNDATIONS MFS Trenches For retaining wall details see Model Details MRW1 or MRW2, Tension lap ee —— oo 25 for internal faces. 40 for external exposed faces. Seg oe te DETAIL 'A’ Wall thickness 150 or less. Tension top (=1.4 a fnchorege Terai Tension lap Splay bars used when design moment specified Tension to x Anchorage Tengthy DETAIL 'B’ Wall thickness more than 150, MES.DWG Ove Arup Partnership March 2006 RETAINING WALLS MRW1 External cantilever wall Vertical bors placed on outside for earth faces. Horizontel bars placed on outside for exposed faces. Bor size and pitch for earth foce Tension lap: es specified oy designer. 40 for externally exposed faces. 50 for buried faces. Bor size and pitch for exposed face (based on minimum wall thickness) ven in tavle of Model Detoil VW? unless stated otherwise Granular fill Tension laps Bar size ond pitch os specified by Kicker50/ Sesianer 5 758 Tension lap: 5 Nominal reinforcement, see Model 7 1 Detail MS1, unless stated fension lap otherwise. Key added if ond where required. Large radius of bend specified by designer if necessary, MRW1.OWG Ove Arup Partnership March 2006 RETAINING WALLS MRW2 Basement retcining wall. Tension lop Detclls of waterbors as specified b} vertical reinforcement fixed first for ease of construction, 50 for buried faces. 25 for internal faces; see 5.2.2 40 for external exposed foces. Reinforcement not specified by designer is given by nominal steel toble for Model Detail MW1. Tension lop Kicker: 150 Wall placed centrally on ground beam, 300. minimum overlap, 8 Large radius of bend specified by 5 designer if necessary. Tension lap Tension) lap Covity drain siot Kicker: 150 Floor to falls Top of heel level with ——. ) 75 bottom of cavity drain. 300 minimum & overlap, Large radius of bend specified by designer if necessary. Tension lop Tension| lap 75 Tension lap MRW2.0NG Ove Arup Partnership Morch 2006 RETAINING WALLS MRW3 Vertical construction joints Splice bors of the some size ond pitch as main bars. 25 for internal foces. 40 for external exposed faces. 50 for buried feces; see 32.2 Tension lop Tension lop 50. DETAIL ’A’ Simple construction joint 50 If dowel bor specified see Model Detail MFS. 3. Spacing of joints should be a 30m moxirum, T10 ‘U" bors zs] | ys IF inlerel woter boris tot required 'U' bars are DETAIL 'B Gisbleced to ovoid Clesh Full contraction joint For detcils of waterbars and exparsion joints see CIRIA Report 139 ‘Woter-resisting basemenis Bb 3 DETAIL 'C’ Movernent joint NRW30.0WG Ove Arup Partnership March 2006 SLABS MS1 One and two way slobs. Span and internal support. For edge support details see Model Detail MS2. Nomine! cover:— Specified by designer (At least 25 or bar size whichever is greater; see 7.2.2) Generally curtailment of the main longitudinal reinforcement should relcte to the bending moment Giogram. See design and detailing notes 7.2.6 Top bors alternately stoggered shown, unless otherwise Pitch of cistribution bors os given specified in table, unless otherwise specified Not less than 2 (No. bars, 0.1 x short span or 600 whichever 1s shorter. 0.5 x tension lop 19.5 x tension lap Bottom bars of length 0.8 x spon + 0.5 x tension lap olternately reversed as shown, unless otherwise specified Piteh of distribution bars (mm) Bor Sleb depth (mm) (mm) [700 [125 [150 [175 [200 [225 ]250 [275 | 300 [325 [350 [375 [400 io | 350 [425 [425 | 350 [300 [ 275 | 225 | 200 | 200 [175 [150 [150 ]125) 12 | — | —]450 [450 [450 [400 [350 [325 | 275 [250 [250 [250] 200 is | —[—[— —]450 [450 [450 450 [450 [425 [400] 375 MS1.0WG Ove Arup Partnership March 2006 SLABS MS2 One and two way slabs. External restrained supports. Distribution bors os for Model Detail MS1 Nominel cover:— Specified by designer (At least 25 or bor size whichever is greater: see 7.2.2) 0.3 x span 0.1 x span or 600 whichever is smaller, This detail is used when 'X' is more than an anchorage length. Otherwise details “8” or 'C’ ore used. "U' bars alternately placed. The orea of "U' bars equals holf the bottom steel at mid span unless otherwise specified, 500 or tension lop whichever is greater. A bar is placed inside ecch corner. DETAIL ’A This detail is used when ‘x’ is Curtailment of top bars in slob as less than an onchorage Specified. Minimum os for detail ‘A’ length, provided that the bearing ‘stress inside the stonderd bend does not exceed the limit. Otherwise detail 'C' is used 2 Tension anchorage length———+ 0.5 xp Bars extending down into wall from slab should be detailed with the wall drawings wherever possible, Otherwise they must be DETAIL °3” “ery cross referenced This detail ‘s used when the Curtailment of top bors in sled as bearing stress inside the specified. Minimum as for detail ‘A’ bend requires a non— me stondard radius of bend, Tension anchorage length Bars extending down into wall from slab should be detailed with the wall drawings wherever possile. Otherwise they must be } DETAIL °C’ “arly cross referenced MS2.0NG Ove Arup Partnership Morch 2006 SLABS MSS One and two way slabs. External unrestrained supports. These details clso apply to free edges. Distribution bars os for model Detail MS1 Nominal cover:— Specified by designer (At least 25 or bar size whichever is greater; see 7.2.2). This detail is used for slob depth 150 or greater. Detoils 'B' or 'C’ are used for slab depth less than 150. 0.1 x spon or 45 x bor dio whichever is greater End 'U' pars are same dia as bottom bors. 500 or tension lap whichever is grecter. DETAIL A’ (Slab depth 150 or greater) This detail is used for support 500 or tension lap whichever is width less thon 200, greater. Otherwise detail ‘C’ is used The greater of 4, 0.3 lb,rad, 10 times bor dia. or 100, (see 7.2.6) Bobbed bors moy be lid ‘over to ensure sufficient top Support width: DETAIL *B" (Slab depth less than 150) The greater of d, 0.3 Ibyrad, This details used for support 10 times bar dia, or 100, width 200 or more, (see 7.2.6) Otherwise detail 'B” is used, This. detail is also suitable for fodric reinforcement. Support width: DETAIL ’C’ (Slab depth less then 150) Ms3.0WG Ove Arup Partnership March 2006 300, 0.5 x cantilever, SLABS MS4 Cantilever slabs. Distribution bars as for Model Detcil MS1 Nominal cover: Specified ay designer (Mt least 25 or bar size whichever is grecter; see 7.2.2) ‘The length of main cantilever top bors should be specified, They should be minimum of 2 x contilever length over simple supports clternately staggered 9s shown, "U' bor ensures lever arm retained: MS4.0WG 0.5 x tension lop Area of bottom reinforcement should be at leost 0.5 x orea of top reinforcement to control deflection, Ove Arup Partnership March 2006 When equivalent column die. less thon 0.15 x wicth of panel % of the bors for this strip should be placed in the centre half Distribution bars of length SLABS Flat slabs. Span and internal support. MSS Edge details include o 'U’ bar os shown in Model Detail MS2 A, Curtailment of mein bars as for Model Detail MS1 Nominal cover:— Specified by designer (At least 25 or bor size whichever is grecter; see 7.2.2) MSS.DWG Move! Dera MST oy” {LE | Dm Ph PL PL Bt Lt J L L L| | L | | | f fel 2p Two bottom bors) shou i Bess hcugn cline y ‘r Middle strip Column strio SECTION OF COLUMN ste | | | \ \ \ afe|e i» |p SECTION OF MIDDLE STR' pi: pitch of column strip top bars. DL: pitch of middle strip top bors. Bi: pitch of Py: pitch of Bors of the longer spon are placed outer loyer unless otherwise specified. Ove Arup Pertnership IP column strip bottom bors. middle strip bottom bors. in the March 2008 SLABS MS6 Flat slabs. Shear reinforcement. Curtailment of main bars as for Mode! Deteil MS1 Nominal cover:— Specified by designer M least 25 or bar size whichever is greater; see 7.2.2) The links may be fixed to the some levels of reinforcement wherever they occur on the perimeter, provided thot nominal hanger bars are included wherever necessary, 0.75d,, 0.754 0.5q Lot: Coq es Links should be placed on rectangulor olan 12 dic. fixing bers are required to perimeters spaced as shown from column locate the links in those positions face. The links are spaced evenly around each where main reinforcement is not perimeter with o maximum pitch of 1.5d within present. These bors should 2d from the column face and @ maximum extend © tension anchorage pitch of 2d outside this. beyond the last tink MS6.DWG Ove Arup Partnership March 2006 SLABS MS7 Flat slobs. Column drops This detail is not suitable when the bottom steel in the column drop is used in design in such circumstances ‘the reinforcement details should be specified by the designer. Nominal cover:— Specified by designer (At least 25 or bar size which ever is greoter; see 7.2.2) 175 minimum The mein bottom bars are corried through the column drop. Nominal reinforcement is provided in the bottom of the drop:— 12 dia. bars ot 300 itch, MS7.DWG Ove Arup Partnership March 2008 Nominal fabric A252 is provided, unless otherwise specified SLABS MS8 Ribbed and coffered slabs. Nominal cover Specifies by designer (At least 25 or bar size whichever is greater; see 7.2.2) Special care should be given ensure sufficient cover where fabric. overlaps, 300_unless_otherwise specified e e e In order to ensure tlow of concre! bottorn of ribs the minimum width of 1b for )) one ber is 75, i) two bars side by side is 126. DETAIL ‘A’ (Hollow pot) r 300 unless otherwise) specified. | | 12 dia if ove DETAIL ‘B’ (Coffered slob) Ms8.0WG Ove Arup Partnership Nominal fabric 4252 is provided, unless otherwise specified p+ 12d minimum Closed inks should be provided if required for shear. It cover exceeds 40 supplementory reinforcement may be required for fire resistance. Ths is provided by Emm links es shown (Max. piten 200) plus nominal lecer bar for coffered slabs. DETAIL °C’ (Coffered siab with supplementary reinforcement) March 2008 [25 Tension lap STAIRCASES MST1 End supported with landings. Distribution bors os for Model Detail MSt "U' bars for both landings to be 50% of the area of the main baltom reinforcement 'K’ to be the greatest of 0.1. x design span, tension anchorage length or 500. For detail where landing reinforcement spans in other direction see design notes 8.2.6 See also Mode! Detail MWS. Nominal cover:~ Specified by designer (Minimum 25 ar bar size whichever 's greater: see 8.2.2). See also design notes 8.2.6 Tension anchorage joint [Construet Z| Construction MST1.OWG Ove Arup Partnership 25. Tension lap Similar bars to main bottom reinforcement. Similar bars to moin bolton reinforcement. March 2006 STAIRCASES MST2 Cantilever from wall or edge beam Main cantilever bars must be mild steel if they are to be rebent. See Model Detail MWS. Nominal cover:— Specified by designer (Minimum 25 or bar Sze whichever is grecter; see 8.2.2) Linking to be 78's at 300 unless otherwise specified. N.B. Bends to be odjusted to suit on sie [ Position of 18 "U’ bar. Specified by designer. Distribution bars to be T10's at . 300 unless otherwise specified Corner bar detailed Nominal 18 "U' bar with woll. Design reinforcement —y Tension anchorage A-A MST2.0WG Ove Arup Partnership Moreh 2006 'U' bars provided at top. Compression lop unless: specified otherwise, WALLS MW1 General Details. Horizontal bars are cid outside vertical bers, Nominal _cover:— Specified cover by designer (At least 25 or bar size whichever is grecter; see 5.2.2) Where there is no specific design requirement the bar size and pitch given below may be used, Vertical [Horizontal bars | bars Dia.[Pitch [Dio.|Pitch 150-178 [121300 tio | 200 +75=200_[12[ 250110 | 200 200=250_|12 [200 [10 | 200. 250-300 | 16 | 300 [10 [200 Wall thickness Projection above floor level:~ Compression lop + kicker height Unless specifies otherwise. Structural floor level 300-400_[16 [250 [12 [200 400=500_| 16 [200 [12 | 150. 500-600 [20 | 250 [16 | 200 600=700_| 20 | 200_|16 | 200. 700-800 [20] 200 [16 | 200 Kicker: 75 Compression lap + 150 for foundation level tolerance, Koken: 75 (150 below ground) For edge walls the starter bars for slabs shown on Mode! Detoil MS2 B & C should be detailed with the wall drawings wherever possible. Otherwise they must be Clearly cross referenced Vertical bars rest on kicker. 'U bars provided at bottom. MW1.0WG Ove Arup Partnership March 2006 Two bars should be placed within loop for wall thickness 300 ond less. For wall thickness over 300 four bors should be included os shown. MW2.0WG WALLS MW2 Corner details For cover, size and pitch of main bors see Model Detcil MW1 unless. specified othernise, 'U' bors to be some size cond pitch as horizonte! bars. Tension lop Ove Arup Partnership Merch 2006 WALLS MWS Half landing detail For cover, size and pitch of wall bars see Mode! Detail Mw For details of slob bars see Model Detail MS2, but U" bors to be mild steel ‘and of size not greater thon 12 For details of staircases see Model Details MST! & MST2. Horizontal wall reinforcement not shown for clarity. Bars are pre-bent to fit flush Two fixing bors ore———1t with the shutter. placed inside 'U' bars. Tension lap MW3.DWG Ove Arup Partnership March 2006 WALLS = MW4 Hole details For cover, size and pitch of main bars see Model Detci’ wi | | I L I I Tenson encase tens] || tend eter |] |-_—empession o us seit I I I Dieter of ins ba ison o size larger than vertical bars. For walls less than 250 thick only Trimmer bars at side of ———— xt — Hole one trimmer bar of equivalent opening, L crea is used. DETAIL ’A’ Section through top of opening. Section through bottom similar. Hole. Tension anchorage length: r beyond trimmer bors. t— Irimmer bars above and below. Diometer of trimmer bars is one size larger than vertical bars. For wall thickness of 200 or less only one trimmer ber on each side of the hole is uses. Tension lap. DETAIL 'B’ Section through left of opening, Section through right similar. Mw4.DWG Ove Arup Partnership Merch 2006

You might also like