Load and Linear Guide: Call 1-800-GO-VEXTA (468-3982) or 1-847-871-5931
Load and Linear Guide: Call 1-800-GO-VEXTA (468-3982) or 1-847-871-5931
- given information -
Efficiency η = 80 [%]
External force
FA = 100 [N]
Mechanism Placement
Mechanism angle α = 0 [°]
Other requirement(s)
Is it necessary to hold the load even after the power supply is turned off? → NO
Is it necessary to hold the load after the motor is stopped, but not necessary to hold after → NO
the power supply is turned off?
Operating conditions
Stopping accuracy
Safety factor
- calculated result -
Load Inertia
Jm = m ×( (Dp×10-3 ) / 2 )2
Required Speed
Vm = V1 ( 60 /( π Dp )) ( Dp2 / Dp1 )
Required Torque
T = ( Ta + TL ) ( Safety Factor )
Acceleration Torque
Ta = JL ( Vm / ( 9.55 × t1 ))
Load Torque
Other requirement(s)