Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

Product page >

Data Sheet

ASMi-54
SHDSL.bis Modem

• SHDSL.bis managed modem operating at full-duplex data rates of up to 5.7 Mbps per
copper pair
• Ethernet service over 8-wire line of up to 22.8 Mbps in Point-to-Point, Multipoint,
Daisy Chain and Ring topologies
• Two platforms for Ethernet encapsulation with up to 22 Mbps throughput over 8-wire
lines: HDLC and SHDSL EFM bonding (in Point-to-Point topology)
• Optional 4xE1 service in addition to HDLC encapsulated Ethernet in Multipoint, Daisy
Chain and Ring topologies

ASMi-54 is a simple, cost-effective, • Daisy-chain and Ring topologies for Table 1 illustrates the topologies and
dedicated managed SHDSL.bis modem that Ethernet connectivity – ASMi-54 features supported by selected ASMi-54
extends the range of high-speed services enables service resiliency and options.
over existing copper pairs. protection by implementing the ITU-T The modem also features line probing
The modem features a variety of topologies, G.8032 ETH ring protection switching according to G.991.2. When enabled, the
which extend up to 4 E1 and 4 ETH ports standard for bandwidth of up to SHDSL interface adapts its rate to the
with integrated switch to the SHDSL line. 11.4 Mbps condition of the line (noise, loop
ASMi-54 operates in the following • Multipoint – each ASMi-54 operates attenuation, etc.). When disabled, the
topologies: with four ASMi-54L modems to enable SHDSL line operates at a fixed rate
extension of E1 and selected by the user.
• Point-to-Point –extending traffic on HDLC-encapsulated Ethernet traffic,
four Ethernet links at rates of up to ASMi-54 can operate as a CO device or a
while connectivity towards the IP CPE device according to user
22.8 Mbps (EFM bonding) network can be either copper or fiber, configuration.
Note: Refer to Table 1 for the EFM supporting using an SFP transceiver
Up to eight SHDSL repeaters can be
options. • Point-to-Point – four Ethernet links installed in-line to increase the operation
(HDLC encapsulation) in addition to range of E1- and Ethernet-based modems.
four E1 ports, up to 22.8 Mbps.
ASMi-54
SHDSL.bis Modem

TECHNOLOGY Ethernet Quality of Service


ASMi-54 features up to four Ethernet The 802.1D DSCP schemes allow users to
EFM Bonding
10/100BaseT ports with half/full-duplex define different QoS levels according to
EFM bonding on the Ethernet interface
autonegotiation and flow control. application requirements.
ensures that a failure or addition of a link
does not drop the traffic being Fault propagation enables the unit to shut The modem implements the IEEE's 802.1q
transmitted over the other wires in the down the Ethernet user port when an standards to provide VLAN-tagging with
group. The capacity of the group does not SHDSL line failure is detected. LANs are four levels of prioritization, enabling
decrease when a new link is added connected by bridging. carriers to offer differentiated Ethernet
operating at a lower rate. services.
The internal forwarding of Ethernet traffic
The modem transports Ethernet can be configured by:
point-to-point at the rate of up to • Specifying the ports (a mode identified
22.8 Mbps using EFM bonding technology, as unaware in accordance with Metro
which enables each link to synchronize at a Ethernet Forum (MEF) standards). In
different rate. this mode, all the Ethernet traffic
Note: This feature relates to Ethernet service in reaching one of the ports is forwarded
point-to-point topology only (see EFM supporting to the other port, and vice versa
options in Table 1). • Using VLANs for classification (a mode
identified as aware in accordance with
Metro Ethernet Forum (MEF)
standards). In this mode, Ethernet
traffic reaching one of the ports is
forwarded to another port in
accordance with its VLAN identifier.

Airmux Airmux

ETH ETH
SHDSL SHDSL FO SHDSL

ASMi-54 ASMi-54 ASMi-54 ASMi-54 ASMi-54

Video PC Video PC Video PC


Camera Camera Camera

Figure 1. Daisy Chain over any Infrastructure for HDLC-Encapsulated Ethernet


Data Sheet

VLAN tagging can also be employed to The following security protocols are • Redundant AC/DC wide-range power
separate traffic, ensuring transparency of provided by ASMi-54 to ensure client supply configuration in a 1U-high
the customer traffic and bolstering security server communication privacy and correct 19-inch metal enclosure (Ring and
of management traffic. The user can user authentication: Daisy-chain topology only)
activate or deactivate the priority • Access control for SNMPv3, Telnet and • 24 VDC
mechanism, and each priority (VLAN Web-based management interface for
priority, DSCP) can be configured and • Via power feeding of DC voltage over
granting access only to users that the SHDSL line (4-wire and 8-wire
mapped to one of four priority queues. appear in the manager list Ethernet versions only).
MANAGEMENT AND SECURITY • SSL/SSH for Telnet and secure Web
access ARCHITECTURE
The ASMi-54 unit can be managed using
the following connections: • RADIUS for password management and ASMi-54 is supplied in 1U-high plastic,
user authentication. metal (8.5- or 19-inch), or rail-mount
• Local RS-232 terminal enclosures.
Note: Refer to Table 1 for the security protocols
• Telnet server, SNMP Modems with metal and plastic enclosures
supporting options.
• Web-based management application can be mounted alone or in pairs in a
• Inband management with or without POWER 19-inch rack using RAD’s optional
dedicated VLAN. ASMi-54 is available with several power mounting kits. 8.5-inch units in metal
options: enclosure can also be mounted in an
8.5-inch rack (see Ordering).
• AC/DC wide-range (100 to 240 VAC,
-48 to -60 VDC nominal)

LAN LAN

LAN LAN

Up to 22.8 Mbps

8-wire SHDSL
ASMi-54 ASMi-54

LAN LAN

LAN LAN

Figure 2. Fast Ethernet Services over SHDSL Supporting EFM Bonding


ASMi-54
SHDSL.bis Modem

E1 INTERFACES
Specifications HDLC

2W: 192 to 5696 kbps (n x 64 kbps, n=3 Number of Ports


SHDSL INTERFACE to 89) 4 x RJ-45

Number of Ports 4W: 384 to 11392 kbps (n x 64 kbps, n=6 Coding


2 to 178) HDB3

Type 8W: 768 to 22784 kbps (n x 64, n = 12 to Impedance


Symmetrical PSD 356) 120Ω, balanced
8-wires unconditioned dedicated line 75Ω, unbalanced (via adapter cable)
(twisted pair) Range
Jitter
Typical Ranges
Connectors As per ITU G.823
(26 AWG, noise-free)
RJ-45
Connectors
Data Rate 2-wire
Bonding RJ-45
[kbps] [km] [miles]
Per IEEE802.3ah and ITU-T G.991.2
192 6.6 4.1 Loopback Tests
Note: Applicable to Ethernet service in the Local analog loopback
point-to-point topology only. 1536 4.9 3.0 Remote digital loopback
Line Coding 2048 4.5 2.8
16 or 32 TC-PAM ETHERNET INTERFACES
4096 3.2 2.0
Number of Ports
Frame Size 4608 3.0 1.9
4 x UTP
2048 bytes
5696 2.6 1.6 3 x UTP + 1 SFP socket
Note: For version 3.5 and above. 2 x UTP + 2 SFP socket
Line Rate Type
Impedance
EFM 135Ω 10/100BaseT
100BaseFx
192 to 5696 kbps in steps of 64 kbps for
Compliance
each 2-wires Connectors
ITU-T G.991.2, ETSI TS 101524
n x RJ-45
n x SFP

Frame Size
2048 bytes

4 x E1 4 x E1
IP/ETH
Network

RNC 4 x BTS
8W

22.8 Mbps
ASMi-54 ASMi-54

TDM
Network
4 x ETH 4 x ETH

BSC 4 x Node B

Figure 3. Connecting Co-located 2G/3G Base Stations Point-to-Point


Data Sheet

CONTROL PORT Indicators Rear Panel


Ethernet Ports ACT (per port)
Interface Front Panel
Yellow (flashing) - Ethernet traffic on
V.24/RS-232 PWR
the port
Green (on) - Power supply on
Type Ethernet Ports LINK (per port)
DCE TST
Green (on) – Ethernet port link is up
Format Yellow (on) – Test in process
Green (off) – No Ethernet link on the
Asynchronous; 8 bits, 1 stop bit, no parity ALM
port
Data Rate Red (on) – Alarm is detected
E1 LOC
9.6, 19.2, 115.2 kbps SHDSL SYNC (per line)
Red (on) –Loss of signal or sync loss
Connector Green (on) - Line is synchronized and (framed mode only), or unframed
9-pin, D-type, female can pass data AIS is received on the E1 port
Green (flashing) - Line is in training E1 REM
MONITORING AND DIAGNOSTICS process
Red (on) –Remote alarm is received on
Real-time alarms Red (on) - Line is not synchronized the E1 port
SHDSL, E1, and Ethernet statistics
collection
Local and remote loopbacks

E1

2W BTS
5.7 Mbps
ASMi-54L ETH

E1
Node B
4 x E1
IP/ETH
Network 2W BTS
5.7 Mbps
RNC ASMi-54L
ETH

E1
Node B
ASMi-54
2W
TDM BTS
5.7 Mbps
Network
ASMi-54L
4 x ETH ETH
BSC
E1
Node B

2W BTS
5.7 Mbps
ASMi-54L ETH

Node B

Figure 4. Connecting Co-located 2G/3G Base Stations using ASMi-54L Modems over Copper Lines
ASMi-54
SHDSL.bis Modem

TIMING Remote Power Feeding 19-inch metal enclosure:


CO mode: Via SHDSL line, 120 VDC maximum (4-wire Height: 44 mm (1.7 in)
 Internal – derived from the modem or 8-wire, for units with Ethernet service Width: 427 mm (17.0 in)
 External – derived from E1 port only) Depth: 258 mm (10.1 in)
Weight: 4.0 kg (8.8 lb)
CPE mode: Physical
Plastic enclosure: Rail-mount metal enclosure:
 Receive – derived from the SHDSL line
Height: 43.7 mm (1.7 in) Height: 150 mm (5.9 in)
Width: 220 mm (8.6 in) Width: 70 mm (2.8 in)
GENERAL
Depth: 170 mm (6.7 in) Depth: 163 mm (6.4 in)
Power Supply Weight: 0.6 kg (1.3 lb) Weight: 0.9 kg (1.9 lb)
Wide-range AC/DC: 100 to 240 VAC,
8.5-inch metal enclosure: Environment
-48 to -90 VDC nominal
Height: 43.7 mm (1.7 in) Temperature: 0° to 50°C (32° to 122°F)
Note: Redundant AC/DC wide-range power supply
Width: 215.5 mm (8.5 in) Extended temperature (4 x ETH interface
configuration is available in a 19-inch metal
Depth: 153 mm (6.0 in) version only): -20° to 70°C (-4° to 158°F)
enclosure (for Ring or Daisy-chain topologies only).
Weight: 0.7 kg (1.5 lb) Humidity: Up to 90%, non-condensing
DC: 24 VDC nominal

E1s

Central Office
Fiber
4 x E1 BTS
IP/ETH
Network Optimux-108
FE

RNC BTS Site


Node B

4 x ETH 4 x E1
LRS-102
TDM Megaplex-4100
Network Copper BTS
SHDSL.bis
BSC 1 x GbE ASMi-54
n x ETH 4 x FE
n x E1

BTS Site
Node B
Airmux-400
Wireless

E1s

BTS

Airmux-400
FE

BTS Site
Node B

Figure 5. Connecting Co-located 2G/3G Base Stations using Fiber Optic, Copper and Wireless Connections
Data Sheet

Ordering
RECOMMENDED CONFIGURATIONS

ASMi-54/4ETH/8W
EFM support, ver. 2.x, metal enclosure

ASMi-54/4E1/4ETH/8W
Four E1 ports, no EFM support, ver. 3.x,
plastic enclosure

ASMi-54/4ETH/8W/M
Multipoint capabilities, no EFM support,
ver. 3.x, plastic enclosure

ASMi-54/4ETH/8W/D
Daisy-chain/ring capabilities (4W on each
side), no EFM support, ver. 3.x, plastic
enclosure
ASMi-54/4ETH/8W/D/R
Daisy-chain/ring capabilities (4W on each
side), no EFM support, ver. 3.x, 19-inch
metal enclosure with redundant AC/DC
wide-range power supply)

SPECIAL CONFIGURATIONS
Please contact your local RAD partner for
additional configuration options.

Table 1. Special Topologies and Features

ASMi-54 Options EFM/Version Topology SFP Socket Security


Protocols
ASMi-54/4ETH/8W Yes/2.x Point-to-point No No

ASMi-54/4E1/4ETH/8W No/3.x • Multipoint opposite LRS-102, Yes Yes


Megaplex-4100 or ASMi-54L
• Point-to-point
ASMi-54/4ETH/8W/D No/3.x Daisy-chain and Ring Yes Yes

ASMi-54/4ETH/8W/M No/3.x Multipoint Yes Yes


Data Sheet
ASMi-54
SHDSL.bis Modem

SUPPLIED ACCESSORIES OPTIONAL ACCESSORIES WM-35-TYPE4

other trademarks are the property of their respective holders.


product is covered by which patent, please see ipr.rad.com. The RAD name, logo, logotype, and the product names MiNID, Optimux, Airmux, and IPmux, are registered trademarks of RAD Data Communications Ltd. All
503-100-11/16 Specifications are subject to change without prior notice.  1988–2016 RAD Data Communications Ltd. RAD products/technologies are protected by registered patents. To review specifically which
AC power cord Wall mounting kit for 8.5-inch units with
RM-33-2
AC/DC adapter for -48 VDC metal enclosure
Hardware kit for mounting one or two
RM-34 plastic ASMi-54 units in a 19-inch rack CBL-DB9F-DB9M-STR
Mounting kit for installation of one Control cable
RM-35/@
ASMi-54/4ETH/8W/D/R in a 19-inch rack
Hardware kit for mounting one or two CBL-RJ45/2BNC/E1
8.5-inch metal ASMi-54 units in a 19-inch Interface adapter for converting a
rack balanced E1 RJ-45 connector into a pair of
Legend BNC unbalanced coaxial connectors
@ Rack mount kit (Default=both kits):
P1 Mounting one unit
P2 Mounting two units

PC PC

Video Video Video Video


Camera Camera Camera Camera

ASMi-54
SHDSL SHDSL
ETH
SHDSL
Fiber
Ring
ASMi-54 ASMi-54 ASMi-54
ASMi-54

PC PC

Figure 6. Ring and Daisy-chain Capabilities

International Headquarters North America Headquarters


24 Raoul Wallenberg Street 900 Corporate Drive
Tel Aviv 69719, Israel Mahwah, NJ 07430, USA
Tel. 972-3-6458181 Tel. 201-5291100
Fax 972-3-6498250, 6474436 Toll free 1-800-4447234
E-mail market@rad.com Fax 201-5295777
E-mail market@radusa.com

www.rad.com Order this publication by Catalog No. 803759

You might also like