The Next Generation of Data Centers Is Here.: 3M Immersion Cooling
The Next Generation of Data Centers Is Here.: 3M Immersion Cooling
The next
generation of
data centers
is here.
2
The rise of the data economy is fundamentally By transitioning data centers from traditional cooling
changing the way we live and our always-on, highly- methods to immersion cooling with 3M fluids,
integrated world is pushing businesses to operate businesses can better prepare for the unprecedented
at an ever-increasing pace. Almost every aspect of performance requirements of the future while
our daily lives — smart devices, homes, cities and managing costs and the impact on our natural
autonomous vehicles — relies on what is happening resources.
inside data centers.
Enter what would otherwise be impossible — a new
However, these centers come at a tremendous cost in era of data centers.
energy consumption, water use, footprint and more.
It’s clear — we need faster, smarter, more energy-
efficient and more sustainable data centers.
Tank
Liquid
Single-phase immersion cooling
In single-phase immersion cooling, fluid remains in
Facility
its liquid phase. Electronic components are directly
Server Water to
Dry Cooler
immersed in dielectric liquid in a sealed but readily-
and/or
Adiabatic accessible enclosure where heat from electronic
Cooler
components is transferred to the fluid. Pumps
are often used to flow the heated fluid to a heat
exchanger, where it is cooled and cycled back into
the enclosure.
Fluid
Direct-to-chip cooling
Server DIMM
Direct-to-chip cooling rejects heat by pumping
DIMM
fluid through cold plates attached to electronic
liquid
cooling
components. The fluid never makes direct contact
cold rails
with electronics. While non-dielectric fluids (e.g.,
CPU CPU
water glycol) are often used in direct-to-chip cooling,
dielectric fluids can be used in direct-to-chip
applications to mitigate risks associated with leaks,
increasing hardware/IT equipment reliability. Direct-
to-chip cooling can be implemented using single-
phase and two-phase technologies.
3
Geographically and environmentally agnostic Simpler data center designs to scale more
Build more consistent cooling infrastructure globally, efficiently
regardless of location decisions and environmental Enjoy smaller and simpler data center topologies (e.g.,
variations. Denser form factors also better enable mechanical, electrical, networking). Simplify data
space- and weight-sensitive applications. center design by eliminating the need for complex
airflow management.
Reduce capital and operational expenses
Reduce capital expenditure by minimizing or Reduce Power Usage Effectiveness (PUE) and
eliminating air-cooling infrastructure (e.g., chillers, water usage
CRACs, CRAHs, PDUs, RPPs, telecom/networking, With PUEs as low as 1.03, build more power-efficient
facility footprint). With increased cooling efficiency, and sustainable data centers. Also, reduce or eliminate
electricity costs dedicated to ancillary cooling needs water waste with either single-phase or two-phase
can be reduced. immersion cooling through the use of dry coolers.
As data center design evolves, our unique experience in immersion cooling can
help you tackle your next data center project.
Get more information and answers to frequently asked questions by visiting our
website www.3M.com/ImmersionCooling.
Not for specification purposes. All values @ 25°C unless otherwise specified.
1
GWP-100 year ITH, CO2 = 1.0, per IPCC 2013, with the exception of Novec 7100 fluid, which notes IPCC 2007.
2
Per closed cup flash point test method.
3
Does not display a closed cup flash point but does display upper and lower flammability limits. See SDS for details.
Data Center Liquid Cooling Applications using 3M™ Novec™ Engineered Fluids
Recommended Operating Temperature Range
200
150
100
Degrees (°C)
50
-50
-100
-150
Two-Phase Single-Phase
Novec 7000 Novec 7100 Novec 7200 Novec 7300 Novec 7500 Novec 7700
Maximum1 34 61 65 85 115 155
Minimum2 -120 -105 -105 -30 -75 -30
1
Maximum operating temperature for two-phase liquid cooling fluids is the boiling point; typical values for single-phase liquid cooling fluids is 10°C below the
boiling point.
2
Typical values for single- and two-phase liquid cooling fluids are the measured or calculated temperature at 20-30 cSt viscosity.
To learn more about how 3M fluids can help enable your data center liquid cooling applications, visit
3M.com/immersioncooling.
Not for specification purposes. All values @ 25°C unless otherwise specified.
*
Fluid is considered super cooled at this temperature. Talk to a Tech Service Engineer for more information.
Data Center Liquid Cooling Applications using 3M™ Fluorinert™ Electronic Liquids
Recommended Operating Temperature Range
200
150
100
Degrees (°C)
50
-50
-100
Two-Phase Single-Phase
FC-3284 FC-72 FC-3283 FC-40
Maximum1 50 56 120 155
Minimum2 -65 -80 -60 -30
1
Maximum operating temperature for two-phase liquid cooling fluids is typically the boiling point. Higher temperatures are possible in pressurized systems. Typical
values for single-phase liquid cooling fluids is 10°C below the boiling point.
2
Typical values for single- and two-phase immersion cooling fluids are the measured or calculated temperature at 20-30 cSt viscosity.
To learn more about how 3M fluids can help enable your data center liquid cooling applications, visit
3M.com/immersioncooling.
To learn more about 3M™ Fluorinert™ Electronic Liquids visit 3M.com/Fluorinert. You can also explore our other data
center liquid cooling fluids, 3M™ Novec™ Engineered Fluids, at 3M.com/Novec.
Regulatory: For regulatory information about these products, contact your 3M representative.
Technical Information: The technical information, recommendations and other statements contained in this document are based upon tests or experience that 3M believes
are reliable, but the accuracy or completeness of such information is not guaranteed.
Product Use: Many factors beyond 3M’s control and uniquely within user’s knowledge and control can affect the use and performance of a 3M product in a particular
application. Given the variety of factors that can affect the use and performance of a 3M product, user is solely responsible for evaluating the 3M product and determining
whether it is fit for a particular purpose and suitable for user’s method of application.
Warranty, Limited Remedy, and Disclaimer: Unless an additional warranty is specifically stated on the applicable 3M product packaging or product literature, 3M warrants
that each 3M product meets the applicable 3M product specification at the time 3M ships the product. 3M MAKES NO OTHER WARRAN TIES OR CONDITIONS,
EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OR CONDITION OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE OR ANY IMPLIED WARRANTY OR CONDITION ARISING OUT OF A COURSE OF DEALING, CUSTOM OR USAGE OF TRADE. If the 3M product does not
conform to this warranty, then the sole and exclusive remedy is, at 3M’s option, replacement of the 3M product or refund of the purchase price.
Limitation of Liability: Except where prohibited by law, 3M will not be liable for any loss or damage arising from the 3M product, whether direct, indirect, special, incidental
or consequential, regardless of the legal theory asserted, including warranty, contract, negligence or strict liability.