Dew Point Temperature Calculation: Customer

You might also like

Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 2

CUSTOMER:

DEW POINT TEMPERATURE CALCULATION


% 100 100

DESCRIPTION COAL R.H

H2O by vol % 22.42 14.96


SO2 by vol % 0.04 0.03

Partial pr of water Vapour (PH2O) mmHg 174.58 116.49

Ln(PH2O) 5.162 4.758


Partial pr of SO2 (PSO2) mmHg 0.00623 0.00467
Ln(SO2) -5.079 -5.366
Dew point tempTdp k 417.115446295409 410.130546379345
°C 144 137
VESPL/BPL/DOC/1052 -01
70+30 30+70

COAL+R.H COAL+R.H

10.83 13.28
0.08 0.05

84.33 103.41

4.435 4.639
0.01246 0.00779
-4.385 -4.855
416.439786846665 413.808658027863
143 141