Tenant Design Standards: Terminal and Concourse Areas
Tenant Design Standards: Terminal and Concourse Areas
3.0 STRUCTURAL
3.1 Modifications and Alterations 31
3.2 Penetration of Landlord’s Floor Structure 32
3.3 Design Loads 32
5.0 ELECTRICAL
5.1 General Requirements 39
5.2 Power & Telecommunications 39
5.3 Lighting 40
S a l t L a k e C i t y I n t e r n a t i o n a l A i r p o r t Te n a n t D e s i g n S t a n d a r d s
4 prepared by ajc architects, January 2011
P R O J E C T I N F O R M AT I O N
I.0
1.0 P R O J E C T I N F O R M AT I O N
1.1 INTRODUCTION
The Salt Lake City Department of Airports Tenant Design
The Salt Lake City Department of Airports (SLCDA) and its
Standards, referred to in this document, the Tenant Im-
Concessionaires /Tenants are responsible for the first im-
provement Guidelines (TIG), and the Lease Agreement as
pression of most visitors. This first glimpse of the Intermoun-
TDS, has been prepared to assist Tenants and their archi-
tain Area and Salt Lake City is an opportunity to showcase
tects, designers and engineers understand and respond
local and regional themes, natural features, resources
to lease requirements regarding design and construction
and history. With this in mind, the objectives of the Airport
of various types of retail spaces at the Airport.
relative to concessions includes the provision of high qual-
ity diverse products that, where possible, relate to or are
The guidelines exhibited in this manual govern Tenant
produced in the Intermountain Area. Visitor experience
improvements to storefronts, floors, walls, ceiling, lighting
should always be the over-riding force in the design of all
and signage. The intent of the TDS is to encourage quality
flow path, queuing, and marketing strategy.
design and consistent standards for all Tenants.
S a l t L a k e C i t y I n t e r n a t i o n a l A i r p o r t Te n a n t D e s i g n S t a n d a r d s 5
1.2 LANDLORD PROVIDED WORK – GENERAL The Salt Lake City Department of Airports has developed
The following work is to be provided by the Owner at the a design review process to assist Tenants and Conces-
Owner’s expense unless stated otherwise in the Lease sionaires in compliance with the Tenant Design Standards
Agreement. adopted by the Airport. These design standards are in
place to provide appropriate quality for architecture,
• The Landlord will provide within the lease area as is. engineering and construction at the Salt Lake City Inter-
New Tenants may be responsible for demolition of national Airport.
all/any existing finishes.
The design review process is established to facilitate com-
• The Landlord will provide utilities to the lease line, as
munication between Tenants and the Design Review Staff.
negotiated in the lease document. All hookups, VAV
boxes, reheat coils, distribution of conditioned air Tenant shall refer to the Tenant Improvement Guidelines,
from the connection point within the premises shall as provided by SLCDA.
be the responsibility of the Tenant, consistent with Air-
port Standards and in compliance with all local and Full architectural, mechanical, electrical, structural (as
national governing codes. See Section 5/Mechani- required) stamped and signed documents are required
cal for more detail. for all new improvements. Registration per State of Utah.
TERMINAL 2
Concourse E
Gates E60-E85
TERMINAL 1
Parking Concourse A
Terminals
Parking
I.0
the TDS, all designs shall also comply with all local codes
and ordinances of Salt Lake City, Salt Lake County, and
the State of Utah.
S a l t L a k e C i t y I n t e r n a t i o n a l A i r p o r t Te n a n t D e s i g n S t a n d a r d s 7
8 prepared by ajc architects, January 2011
ARCHITECTURAL DESIGN CRITERIA
2.0
2 . 0 A R C H I T E C T U R A L D E S I G N C R I T E R I A
S a l t L a k e C i t y I n t e r n a t i o n a l A i r p o r t Te n a n t D e s i g n S t a n d a r d s 9
2.3 SUSTAINABLE DESIGN
Salt Lake City Department of Airports encourages the • Regional Materials: Increase demand for build-
practice of sustainable design in all design decisions of ing materials and products that are extracted and
the Tenant’s build-out. Areas of sustainable design to be manufactured within the region, thereby supporting
incorporated into the Tenant’s design should include: the use of indigenous resources and reducing the
environmental impacts resulting from transportation.
• Water Use Reduction: Maximize water efficiency
Establish a project goal for locally sourced materials,
within buildings to reduce the burden on municipal
and identify materials and material suppliers that
water supply and wastewater systems. Use high-
can achieve this goal. During construction, ensure
efficiency fixtures and occupant sensors to reduce
that the specified local materials are installed and
the potable water demand.
quantify the total percentage of local materials in-
• Construction Waste Management: Divert construc- stalled. Consider a range of environmental, eco-
tion, demolition and land-clearing debris from dis- nomic and performance attributes when selecting
posal in landfills and incinerators. Redirect recyclable products and materials.
recovered resources back to the manufacturing
• Rapidly Renewable Materials: Reduce the use and
process. Redirect reusable materials to appropriate
depletion of finite raw materials and long-cycle
sites. Establish goals for diversion from disposal in
renewable materials by replacing them with rapidly
landfills and incinerators and adopt a construction
renewable materials. Establish a project goal for rap-
waste management plan to achieve these goals
idly renewable materials and identify products and
during construction. Consider recycling cardboard,
suppliers that can support achievement of this goal.
metal, brick, acoustical tile, concrete, plastic,
Consider materials such as bamboo, wool, cotton
clean wood, glass, gypsum wall board, carpet
insulation, agrifiber, linoleum, wheat board, straw-
and insulation. Designate a specific area(s) on the
board and cork. During construction, ensure that the
construction site for segregated or commingled col-
specified renewable materials are installed.
lection of recyclable materials, and track recycling
efforts throughout the construction process. Identify • Certified Wood: Encourage environmentally respon-
construction haulers and recyclers to handle the sible forest management. Establish a project goal
designated materials. for FSC-certified wood products and identify suppli-
ers that can achieve this goal. During construction,
• Recycled Content: Increase demand for build-
ensure that the FSC-certified wood products are
ing products that incorporate recycled content
installed and quantify the total percentage of FSC-
materials, thereby reducing impacts resulting from
certified wood products installed.
extraction and processing of virgin materials. Estab-
lish a project goal for recycled content materials • Low-Emitting Materials/ Adhesives & Sealants:
and identify material suppliers that can achieve this Reduce the quantity of indoor air contaminants
goal. During construction, ensure that the specified that are odorous, irritating and/or harmful to the
recycled content materials are installed. Consider comfort and well-being of installers and occupants.
a range of environmental, economic and perfor- Specify low-VOC materials in construction docu-
mance attributes when selecting products and ments. Ensure that VOC limits are clearly stated in
materials. each section of the specifications where adhesives
and sealants are addressed. Common products to
evaluate include general construction adhesives,
flooring adhesives, fire-stopping sealants, caulking,
duct sealants, plumbing adhesives, and cove base
adhesives.
S a l t L a k e C i t y I n t e r n a t i o n a l A i r p o r t Te n a n t D e s i g n S t a n d a r d s 11
Landlord’s Priorities Materials
In designing each individual RMU, the Landlord has several The design and material selection for the RMU are key
priorities that must be maintained by the Tenant from elements that make up the Tenant’s overall identity
design concept through construction. and merchandise. It is the intent of these TDS to support
that identity. The RMU can be considered as a piece of
• The design of the RMU shall allow access to any furniture, encouraged to be fun, creative and energetic,
existing mechanical/electrical items located within or while respecting the high quality of design and finish of the
adjacent to the lease area for the RMU. surrounding retail Tenants.
• The RMU shall be located and designed in such a
Counters
way to preserve all existing vistas at exterior windows,
Counters need to be durable, high quality, monolithic
minimizing the obstruction of these windows to the
material, with decorative elements added, such as wood
greatest extent possible.
or metal. These elements can be utilized in various ways,
• The design of the RMU shall be inclusive of all func- including a bullnose edge or decorative accent band
tions required of the RMU. “Accessory” items such along the face of the counter top.
as condiments cannot be separate elements, and
must be integral with the overall RMU design. Suggested materials for counters include:
• Stone
• All elements of the RMU must be designed to be fully
lockable and secured. The Tenant is responsible for • Composite-Solid Surfacing
the security of their RMU at all times, whether open
• Metals
for operation or not. This includes the space within
the RMU, along with ALL equipment and merchan- • Glass
• Natural Woods
• Metals
• Metal Laminates
• Tile
• Glass Block
S a l t L a k e C i t y I n t e r n a t i o n a l A i r p o r t Te n a n t D e s i g n S t a n d a r d s 13
2.6 SIGNAGE AND GRAPHICS
Wall Coverings
2.0
explore the space.
• Stucco
This can be achieved when a creative and cohesive
• Brick
store design establishes a complimentary identity for the
merchandise presentation, which is then carried through- • Obscured or translucent glass shall be sand blasted or
out the sales area. Imaginative use of materials and etched—no films or appliques will be permitted
architectural elements, appropriate signage, along with • Anything considered a non-durable material or lack-
creative merchandise presentation, are a few of the tools ing in visual quality
available for the architect.
• Anything considered a fire and/or safety hazard
Finish Treatments Glazing
The finish materials identified in the TDS have been devel- Glass plays an integral role in the storefront design. Properly
oped to provide consistency with the existing Terminal(s) treated, it contributes to the design’s overall effectiveness,
while still offering the Tenant flexibility in design. merchandising presentation and helps reduce “threshold
resistance.” Glass should be treated like any other mate-
In determining the finishes to be used in the storefront
rial and should be used in a way that reinforces the store’s
design, one should consider:
complete design, style and character. In contemporary
• Quality of the material
designs for example, full-height, butt glass is preferable to
• Appropriateness to the character of the store framed windows. Traditional designs could employ articulat-
• Durability and maintenance ed moldings, muntins or beveled glass. Leaded or stained
glass also may be appropriate but may not be used unless
required by local policies. Silicone shall not be used unless
The use of innovative materials is highly encouraged. Ap-
required by code or ordinance, should complement the
propriate materials include:
design and not detract from the beauty of a clean and
• Glass-etched (sealed), sandblasted (sealed), tinted,
uninterrupted view of the store and merchandise.
clear, glass block
• Solid Surfacing Composite Materials- minimally used where a narrow entrance aperture is appropriate, hinged,
pedestrian-sized doors that can be locked in an open
position could be considered as a preferred alternate to an
Inappropriate materials would include:
overhead-rolling gate.
• Artificial versions of stone, marble, tile, wood or other
natural material
• Indoor/Outdoor Carpet
• Fluorescent Paint
S a l t L a k e C i t y I n t e r n a t i o n a l A i r p o r t Te n a n t D e s i g n S t a n d a r d s 15
2.8 FLOOR PLAN/INTERIORS CRITERIA Base
The Tenant is responsible for transitions between SLCDA The Tenant shall provide the wall base throughout their
materials and Tenant material. Special attention will be space at the Tenant’s expense. The Tenant shall use high
given to transitions during the Design Review Process. All quality, durable materials such as stainless steel, ceramic
interior finishes are provided by the Tenant at the Tenant’s tile, stone, or wood. The use of rubber base is not permitted
expense, unless otherwise indicated. in areas viewed by the public, unless approved through the
Design Review Process.
Floor Treatments
• SLCDA provides tile or carpet in the public areas of Wall Finish
the terminal complex, including the concourse cor- • Tenant shall provide all wall treatment within their
ridors, ticket lobby, and bag claim lobby. This SLCDA space at the Tenant’s expense. The use of high quality
provided flooring terminates at different points at the materials will be required.
Tenant’s lease line. See specific area descriptions for
• Plastic laminate, vinyl wall covering, rough textured
more detail.
wood, or imitation materials may be considered and
The Tenant shall provide all flooring within their permitted only for specific applications, as approved
space, at the Tenant’s expense. High quality and through the Design Review Process.
durable materials such as heavy-duty carpet, stone,
• Where stud walls are provided by the SLCDA, the Ten-
wood or ceramic tile are required. The use of vinyl
ant must finish walls with gypsum board to achieve the
composition tile or sheet vinyl is not permitted in
required fire rating. Any penetration must be sealed
areas viewed by the public.
appropriately.
In the event that the Tenant’s floor material has
Security Grille
a pattern, the Tenant shall provide a single color,
• Security grilles are required by the Tenant and ap-
non-patterned border unless otherwise specified,
proved by the SLCDA. All security grilles are to be
to separate the SLCDA provided flooring from the
SLCDA specified grilles provided by the Tenant at the
Tenant’s patterned flooring. The border shall be 18
Tenant’s expense. The design of the space shall allow
inches wide and shall run the entire length of the
convenient access to mechanical and electrical
Tenant’s entry. This threshold shall be provided at the
controls for the grille.
Tenant’s expense.
Window Coverings
The Tenant shall be responsible for all transition
• Exterior Windows. Window coverings on exterior win-
conditions between floor materials. Any required
dows shall be provided by the Tenant at the Tenant’s
transition strips shall be metal.
expense, unless otherwise indicated. Modifications
The Tenant shall provide a waterproof membrane to exterior windows may be allowed, as approved
at all kitchen/food service areas prior to installation through the Design Review Process (i.e., covering the
of finish floor treatment. Waterproof membrane to exterior window with a display wall). The Tenant shall
extend 16” vertical at all walls. comply with many special requirements concerning
modifications to exterior windows.
Glass Graphics
•
their space. See specific area descriptions.
S a l t L a k e C i t y I n t e r n a t i o n a l A i r p o r t Te n a n t D e s i g n S t a n d a r d s 17
Clutter Free Appearance Back Walls
All tenant areas visible to the public shall be carefully A back wall may be built behind the counter separating the
controlled to avoid a cluttered appearance. Dispensers public serving area from the food preparation area. The
for dry storage, cups, straws, cup covers, napkins, and back wall is at the Tenant’s option; however, it is encour-
condiment containers are to be recessed into the coun- aged that a separation exist to maintain a clean and clutter
ter as an integral part of the counter design. free view from the public area. The design of the back wall
is to be an integral element of the design of the Tenant’s
Wall Treatments space and shall be provided at the Tenant’s expense.
Wall treatments should reflect the architecture and im-
age established at the storefront. The rear wall should Walls, Partitions and Separations
emphasize the visual merchandise and store design. • Corridor Demising Wall:
Acceptable wall finishes include: SLCDA will provide corridor walls, which are one (1) hour
fire-rated construction of 6” metal studs and on the
• Wall fabrics framed by architectural elements corridor wall side, taped and painted fire-rated gypsum
• Wood trim, moldings or panel treatments board. The corridor side will be taped and painted. The
Tenant side of the corridor walls will be exposed metal
• Pre-finished or perforated metal panels
studs and shall be finished by the Tenant. All Tenant
• Back-painted or etched glass finishes and modifications to rated walls shall maintain
• Textured paint products the integrity of the rated wall and shall be at the Ten-
ant’s expense.
• Marble, granite or stone
• Demising Wall:
Art and Artifacts
Demising walls between Tenants will be one (1) hour
All art and artifacts shall be submitted, reviewed and
fire-rated construction. Framing will be provided by
approved by the SLCDA and TSA prior to any installation,
SLCDA at SLCDA’s expense and will consist of 6” metal
and shall be consistent with the overall design concept of
studs ready to receive the Tenant’s finish. The Tenant
the space. Minimization of accessories is highly encour-
shall finish walls to a minimum of 6 inches above the
aged.
finished ceiling at the Tenant’s expense. SLCDA will
Fixturing oversee the coordination of adjacent Tenant’s use
Fixturing should compliment and reflect the store attitude, of the demising wall for mechanical and electrical
reinforce the entire design concept, create visual order, purposes.
and be adaptable to permit changes in merchandise Tenant duct work that passes through the demising wall
arrangements. It is important to review all future mer- or corridor wall must be equipped with a fire
chandise categories to ensure appropriate display and damper at the point of penetration and shall be pro-
fixturing capabilities. vided at the Tenant’s expense. If the Tenant plans to
use a demising wall for the support of shelf-standards or
Custom-designed floor fixturing reinforces and enhance
heavy attachments, then the Tenant must reinforce the
the merchandise presentation. Integrate custom fixtur-
wall as needed.
ing with the surroundings so that the merchandise is the
focus. • Walls Within Tenant Space:
Walls within the Tenant’s space shall be provided by
the Tenant and shall consist of twenty 20 gauge metal
studs and 5/8 inches gypsum board. The Tenant shall
finish the walls to a minimum of 6” above the finished
ceiling. These walls shall be constructed at the Tenant’s
expense.
S a l t L a k e C i t y I n t e r n a t i o n a l A i r p o r t Te n a n t D e s i g n S t a n d a r d s 19
Accessories/Hardware Furniture and Equipment
Accessories and hardware make a store design and • All equipment, fixtures, and furnishings shall be pro-
merchandising system work properly and make shopping vided by the Tenant at the Tenant’s expense. The
convenient for customers. Brackets should be hidden or equipment and its placement are important visual
color-coordinated unless they are making a statement elements of the overall design and appearance of
that coordinates with the total store design. Dressing rooms the space. Careful consideration is to be given to
require special attention to such details as hooks, shelves, each piece of equipment in the areas visible to the
seating, door closures and signage. Entrance doors and public.
fixture hardware should be designed for simple operation
• The furniture styles should be compatible with the
and should complement the image of the store.
overall design and the aesthetics of the public
area.
Interior Signage and Graphics
• Tenants with interior seating shall provide high quality
Permanent interior signage and graphics should be three-
furniture that is compatible with the overall design
dimensional, fabricated in a substantial material, and
of the space and with the aesthetics of the Airport.
be submitted with the store design. Promotional and sale
Furniture shall be approved through the Design
signs should be properly designed, framed or suspended.
Review Process.
They should be located no closer than 10 feet from the
storefront lease line. Counters
• Counters are one of the key elements that contribute
Promotional Signage to the Tenant’s overall identify and character.
Promotional signage should be considered at the time The counter area shall be flexible and creative in de-
the store is designed. Printed, well-designed graphics for sign. Tenants shall provide a clearly definable area
promotional signs are permitted. No handwritten, marker- for ordering and checkout. A counter height of 34
style sign will be permitted. All promotional signs will require inches is required with the exception of counter front
a written approval prior to any fabrication or installation. display cases.
•
Glass
• Metal Laminates
• Glass Block
• Stainless Steel
• Plastic Laminates
• Metal Laminates
• Glass
• Ceramic Tile
• Wood
S a l t L a k e C i t y I n t e r n a t i o n a l A i r p o r t Te n a n t D e s i g n S t a n d a r d s 21
22 prepared by ajc architects, January 2011
ARCHITECTURAL DESIGN CRITERIA
2.0
S a l t L a k e C i t y I n t e r n a t i o n a l A i r p o r t Te n a n t D e s i g n S t a n d a r d s 23
24 prepared by ajc architects, January 2011
ARCHITECTURAL DESIGN CRITERIA
2.0
S a l t L a k e C i t y I n t e r n a t i o n a l A i r p o r t Te n a n t D e s i g n S t a n d a r d s 25
26 prepared by ajc architects, January 2011
ARCHITECTURAL DESIGN CRITERIA
2.0
S a l t L a k e C i t y I n t e r n a t i o n a l A i r p o r t Te n a n t D e s i g n S t a n d a r d s 27
28 prepared by ajc architects, January 2011
ARCHITECTURAL DESIGN CRITERIA
2.0
S a l t L a k e C i t y I n t e r n a t i o n a l A i r p o r t Te n a n t D e s i g n S t a n d a r d s 29
30 prepared by ajc architects, January 2011
STRUCTURAL
3.0
3 . 0 S T R U C T U R A L
3.1 MODIFICATIONS AND ALTERATIONS
Any alterations, additional or modifications to the existing Tenant shall, at their expense, enlist the services of a li-
structure required to accommodate the Tenants pro- censed structural engineer to perform calculations regard-
posed improvements to the lease space shall be at the ing the modifications to the existing structural system and
Tenant’s expense. the additional loading of floors and roofs causes by the
equipment, finishes, and merchandise.
This includes the suspension or support of any element
from the floor or roof structure of the existing building. All Tenant shall submit the following information for review by
seismic restraint of equipment and finishes (ceilings etc) SLCDA:
shall also be at the expense of the Tenant.
• Location, size, and weight of any and all equipment.
All additions and equipment shall be placed such that • Rolling grille and storefront weight and supporting
all floor and roof systems are not loaded beyond design details.
loading criteria. Under no circumstances shall temporary
• Location, size and weight of safes and other heavy
loads for building material or equipment exceed the
furniture.
design floor and/or roof load.
S a l t L a k e C i t y I n t e r n a t i o n a l A i r p o r t Te n a n t D e s i g n S t a n d a r d s 31
3.2 PENETRATION OF LANDLORD’S FLOOR AND ROOF
STRUCTURE
Penetrations or installation of equipment of any kind will In spaces with multiple plumbing fixtures, such as kitchens,
not be permitted without prior consultation with a structural dish washing rooms, or restrooms, the Tenant shall install a
engineer at the Tenant’s expense and written approval of waterproof membrane prior to the finished floor. In addi-
SLCDA. The location of approved additional roof penetra- tion, a 6 inches x 6 inches metallic corner flashing shall be
tions will be limited. Penetrations required by the Tenant installed and sealed at all perimeter wall, where the rough
and approved by the SLCDA will be performed by SLCDA’s floor meets rough wall.
contractor to maintain existing warranties in effect. The
Tenant shall be responsible for the costs and must meet all All plumbing and conduit penetrations shall be sleeved
project standards and details. Any unauthorized pen- with a stainless or galvanized, seamless or welded seam,
etrations will be removed and repaired at the Tenant’s metallic sleeve to 3 inches above the finished floor and
expense. flush with the bottom of the floor. The sleeve shall be
precisely sized to fit opening in the concrete. In addition to
Prior to any penetration, finishes must be sampled for sleeving, all openings and sleeves shall be sealed with an
asbestos and other hazardous materials. epoxy-type, non-shrinking, waterproofing adhesive.
4 . 0 H E AT I N G , V E N T I L AT I O N A N D A I R C O N D I T I O N I N G & P L U M B I N G
S a l t L a k e C i t y I n t e r n a t i o n a l A i r p o r t Te n a n t D e s i g n S t a n d a r d s 33
Tenant Work
• SLCDA will provide HVAC to serve the Tenant spaces • The Tenant shall provide all necessary access to
as described above for each area of the Airport. All service their equipment and allow access to all base
hook-ups, variable air volume (VAV) boxes, re-heat building systems.
coils, and distribution of condition air from the
• All supply duct work and kitchen exhaust duct work
connection point within the premises shall be pro-
shall be constructed to SMACNA Standards.
vided by the Tenant, consistent with SLCDA stan-
dards, at the Tenant’s expense. • The Tenant shall be responsible for a normal mainte-
nance and repair schedule for the servicing of the
• If the Tenant’s operation requires modification to the
Tenant HVAC system in accordance with the terms of
air handling system, hydronic hot water or chilled
a standard Air Conditioning Service Contract as used
water system, facility management system, steam
by any reputable service company in the Salt Lake
system, or other central utility, the modifications shall
area, excluding any SLCDA owned and operated
be consistent with the SLCDA standards and at the
system.
Tenant’s expense. Due to the complexity of and
variation in the Airport utility system, the SLCDA rec- • The Tenant shall provide all necessary access to
ommends that the Tenant contact and coordinate service their equipment and allow access to all
with Airport Engineering to determine the specific base building systems. This includes placement of all
requirements for the Tenant’s space. equipment, fixtures, and structural modifications that
may inhibit or deny physical access to devices and/
• All exhaust systems provided by the Tenant shall be
or controls included as part of said systems.
interconnected with the SLCDA Facility Manage-
ment System to permit monitoring of fan status.
These systems shall be consistent with SLCDA stan-
4.3 KITCHEN EXHAUST SYSTEMS
dards and provided at the Tenant’s expense.
Each food service Tenant shall provide its own kitchen
• Tenants providing food service shall be respon- exhaust and make-up system, fabricated and installed
sible to provide their own makeup air and kitchen in accordance with the applicable codes and regula-
exhaust system. The Tenant shall provide all com- tions. Controls for these systems shall be inter locked with
ponents of the system including hoods, duct work supply for Kilair program. Ventilation systems should be of
and insulation, controls, fire extinguishing system, adequate size, strength , and capacity to effectively elimi-
and roof fan with grease trap. Exhaust air shall be nate smoke and odors associated with food preparation,
filtered and directional so that the existing outdoor cooking, and presentation.
air intakes are not infiltrated with cooking odors. All
hookups to the base building fire alarm system shall All kitchen exhaust fans shall be centrifugal up-blast roof
be the Tenant’s responsibility. exhausters with drain and shall be installed in accordance
• The Tenant shall provide an electronic copy of a with NFPA and all applicable codes.
certified balancing report before the system is put
into operation to ensure that the system is exhaust- Kitchen exhaust duct shall be insulated with 2-hour wrap
ing properly. This report shall be reviewed and filed by Thermal Ceramics or equal and per NFPA and Local
with the Owner. codes and Fire Department.
Kitchen hoods shall be water wash grease extractor type
and UL and FM approved.
4.0
• Ducts shall be 10 ga. stainless steel. Ducts shall be RECORD DRAWINGS will identify location of taps.
continuously welded and liquid tight. Construction
standard shall be as required by NFPA standards. Tenant’s Work
• Provide clean out openings with grease-tight access The Tenant is responsible for the design, furnishing, and
panels at each change of direction and at 10ft. installation of complete plumbing systems, as required,
Intervals along straight duct runs. to suit the Tenant’s requirements.
S a l t L a k e C i t y I n t e r n a t i o n a l A i r p o r t Te n a n t D e s i g n S t a n d a r d s 35
All Food and Beverage and Food Court Tenants must 4.6 FIRE PROTECTION
submit drawings for approval to Salt Lake City, the
Requirements for fire protection will be made on a case-
Department of Public Health, and the Office of Food
by-case basis and will be delineated in the lease docu-
Protection and all other Authorities having jurisdiction.
ments. Fire protection design shall be in accordance with
Factory Mutual.
All specifications shall conform to the codes and regula-
tions and to requirements of all authorities having
Landlord Work
Jurisdiction.
The Landlord will provide a central wet automatic sprinkler
system for all Tenants to connect to. An appropriately
In general, materials shall be as follows:
sized hub has been or shall be provided to demise prem-
• Provide plumbing fixtures as indicated on architec-
ises for the Tenant spaces. See LOD for approximate
tural and plumbing drawings. Each fixture, out-
location.
let, and piece of equipment shall be separately
trapped, using type and size of trap required by
Tenant Work
the plumbing code. All traps shall have clean-outs.
All Tenants shall be required to design branch piping
All wall-mounted devices shall have chair carri-
and head layout to coordinate with Tenant’s ceiling and
ers, which shall be securely bolted to floor slabs
space layout.
in accordance with the manufacturer’s recom-
• Ansul systems will be required over all cooking
mendations. Plumbing fixtures shall be Kohler, Eljer
appliances and processes requiring protection as
or American Standard. Final decision as to type of
deemed necessary by the Landlord and review
fixture submitted being equal to that specified shall
authority. Ansul systems are required to connect to
rest with the Tenant’s architect.
the Landlord’s smoke control system and will be re-
• Above-ground hot and cold water piping (all sizes): quired to connect to the airport’s fire alarm system.
• Copper piping type-L, hard temper, except ex- • The Tenant shall provide hand fire extinguishers, as
posed at fixtures and equipment where it shall be required, in the space.
chromeplated cast brass. Wrought copper and
• Obtain hydrant flow test information, satisfactory to
bronze solder joint. Pressure fittings. Joint shall be
NFPA and the insurance underwriter’s requirements,
soldered using silver content lead-free solder.
and in conformance with the timing and require-
• Above-ground sanitary, waste, and vent piping: ments of the SLCDA.
Service-weight cast iron no-hub soil piping conform-
• The systems shall be hydraulically designed and
ing to latest standards. Type-L copper tube may be
supported by hydraulic calculations. Sprinkler work-
used for 2” diameter piping and smaller. All drain-
ing drawings and complete hydraulic calculations
age pipes shall be stainless steel. No-hub double
shall be provided for approval showing the pro-
clamps shall be “Clamp All.”
posed layout of piping based on hydraulic calcula-
tions.
•
spacing of 130 SF per head.
S a l t L a k e C i t y I n t e r n a t i o n a l A i r p o r t Te n a n t D e s i g n S t a n d a r d s 37
38 prepared by ajc architects, January 2011
ELECTRICAL
5.0
5.0 ELECTRICAL
S a l t L a k e C i t y I n t e r n a t i o n a l A i r p o r t Te n a n t D e s i g n S t a n d a r d s 39
• Arc Flash Evaluation. Tenant shall be responsible to 5.3 TENANT WORK: LIGHTING
conduct and provide an arc flash evaluation for all
new electrical equipment such as switchboards, • All storefront and interior reflected ceiling plans and
panelboards, motor control centers, transformers, specifications shall indicate all illuminating devices
and safety disconnects or similar equipment added when submitted to the Landlord’s representative for
as part of tenant improvements and/or modifica- approval. Copies of catalog cuts of fixtures shall be
tions. Arc flash evaluation shall be completed in submitted to expedite approvals.
the responsible charge of a professional engineer • Recessed incandescent down lights shall be used
licensed in the state of Utah and shall include their for storefront illumination and shall be accommodat-
stamp and signature on the final arc flash evaluation ed with a specular or semi-specular alzak cone, and
report. The arc flash evaluation shall include at mini- may be adjustable. Lamps shall not be at or below
mum: computer modeling of electrical system, fault the ceiling line. The use of decorative type lighting,
current calculations, arc flash incident energy levels, such as luminous ceilings, chandeliers, pendant or
arc flash boundaries, arc flash working distance, wall units, or clear-type glitter strips is permitted only if
required PPE FR clothing category, permanent arc the location is approved by the Landlord’s represen-
flash labeling compliant with NFPA 70E (standard tative. Strobe, spinner, or chase-type lighting is not
manufacturer arc flash warning labels complying allowed.
with NEC will not be accepted), and electronic cop-
• General store lighting shall be glare-free fixtures. If
ies of the model and report delivered to the Airport.
fluorescent lighting is used, it shall be recessed, and
• Salt Lake City Department of Airports offers shared the shielding shall be wither metal parabolic, plaster
Tenant telecommunications, and IT services to paracube, or parawedge types. Acrylic lenses are
Tenants of the airport. Shared Tenant services are not allowed for general lighting. HID lighting shall
competitively priced and utilize the robust features have shielding as described above. No electrical
that are available on large dynamic systems. Au- components shall contain materials classified as
tomated attendants, voice mail, shared T1 service, hazardous material.
analog, as well as digital service are available
• Incandescent pendant units may be used for gener-
through the airport’s shared tenant system. Shared
al lighting only if the Tenant has established an iden-
Tenant service allows Tenants to utilize PBX features,
tity based on this theme or motif and if approved by
lower cost for toll calls, and customized restriction
the Landlord.
tables, at the Tenant’s request. Adds, moves, and
changes are included in the monthly port charge, • Exposed fluorescent tube strip lighting is not allowed
and thus are maintained by airport staff. Airport in sales or public areas. All lighting in food service
staff response time for emergency repair situations areas shall have protective covers, globes or shields.
is usually less than two hours. A separate lease • Low-voltage recessed or surface track lighting is
agreement for telecommunication service, with an recommended for high impact on merchandise.
itemized schedule of options is available. Mounting of track and cable systems should use
• If a Tenant chooses to receive telecommunica- manufacturer’s recommended methods and all
tions and IT service from a provider other than the mounting and connections will be reviewed by the
Salt Lake City Department of Airports, the Tenant will Design Review Team.
be responsible for arranging their service from their • To retain and protect the visual environment of the
service provider and complying with airport codes. area for the benefit of all Tenants, each individual
A copy of the airport wiring and cabling standards is Tenant shall control the brightness of the Tenant’s
available. Telecommunications and IT services must lighting fixtures, which shall be subject to the ap-
be approved by the Salt Lake City Department of Air- proval of the Landlord’s representative.
ports. Telecommunications and IT service providers
• The Tenant shall provide all emergency and exit
will need to meet the security, and insurance require-
lighting as required by state and local codes, and
ments to work in these restricted areas. The cost
obtain approval for same from the local authorities.
associated with telecommunications and IT services
will be the responsibility of the Tenant.