Download as pdf or txt
Download as pdf or txt
You are on page 1of 27

GROUP 2 ELECTRICAL CIRCUIT

4-3
CE REGULATION NOT APPLIED

4-4
1. POWER CIRCUIT
The negative terminal of battery is grounded to the machine chassis.
When the start key switch is in the OFF position, the current flows from the positive battery terminal as
shown here.
1) OPERATING FLOW
Battery Battery relay Fusible linkŭCN-60(1)Ů I/connŭCN-5(1)Ů Start key switch
ŭCS-2(1)Ů
I/connŭCN-40(1)Ů
Fuse boxŭNo.19Ů I/connŭCN-38(8)Ů I/connŭCN-6(4)Ů Room lampŭCL-1(2)Ů
Fuse boxŭNo.18Ů I/connŭCN-38(7)Ů ClusterŭCN-8(6)Ů
CPU controllerŭCN-50(10)Ů
Fuse boxŭNo.17Ů I/connŭCN-38(6)Ů Cassette radioŭCN-27(7)Ů

2) CHECK POINT

Engine Key switch Check point Voltage

‫ ڸ‬- GND (Battery 1 EA) 10 ~ 12.5V


‫ ڹ‬- GND (Battery 2 EA) 20 ~ 25V
OFF OFF
‫ ں‬- GND (Battery 2 EA) 20 ~ 25V
‫ ڻ‬- GND (Fusible link ) 20 ~ 25V

Ɠ GND : Ground

4-5
POWER CIRCUIT

4-6
2. STARTING CIRCUIT
1) OPERATING FLOW
Battery(+) terminal Battery relay(M8, B+ terminal) Fusible linkŭCN-60(1)Ů
I/connŭCN-5(1)Ů Start key switchŭCS-2(1)Ů

Ɠ When start key switch is in ON position


Start key switch ONŭCS-2(1),(3)Ů I/connŭCN-4(2)Ů Battery relayŭM4 terminalŮ
I/connŭCN-38(1)Ů Fuse box
I/connŭCN-40(1)Ů Fuse box(No. 18)

Ɠ When start key switch is in START position


Start key switch STARTŭCS-2(5)Ů I/connŭCN-1(1)Ů Start relayŭCR-23(1)Ů
Fuel cut-offŭCN-79(2)Ů

2) CHECK POINT

Engine Key switch Check point Voltage

‫ ڸ‬- GND (Battery)


‫ ڹ‬- GND (Start key)
‫ ں‬- GND (Battery relay M4)
Operating Start ‫ ڻ‬- GND (Start (B)) 20 ~ 25V
‫ ڼ‬- GND (Start (S))
‫ ڽ‬- GND (Start relay)
‫ ھ‬- GND (Battery relay M8)

Ɠ GND : Ground

4-7
STARTING CIRCUIT

4-8
3. CHARGING CIRCUIT
When the starter is activated and the engine is started, the operator releases the key switch to the ON
position.
Charging current generated by operating alternator flows into the battery through the Battery
relay(CR-1).
The current also flows from alternator to each electrical component and controller through the fuse
box.
1) OPERATING FLOW
AlternatorūIŬterminal I/connŭCN-1(2)Ů CPU Alternator power level
ŭCN-51(18)Ů,
Charging lampŭCN-53(7)Ů I/connŭCN-7(7)Ů cluster charging warning lamp
ŭCN-56(7)Ů

Alternator B+ terminal Battery relay (M8) Battery(+) terminal


Fusible linkŭCN-60(1)Ů
I/connŭCN-5(1)Ů I/connŭCN-40(1)Ů Fuse Box

2) CHECK POINT
Engine Key switch Check point Voltage

‫ ڸ‬- GND (Battery voltage)


‫ ڹ‬- GND (Battery relay)
‫ ں‬- GND (Alternator B terminal)
ON ON ‫ ڻ‬- GND (Alternator I terminal) 20 ~ 25V
‫ ڼ‬- GND CPU
‫ ڽ‬- GND CPU
‫ ھ‬- GND Cluster

Ɠ GND : Ground

4-9
CHARGING CIRCUIT

4 - 10
CHARGING CIRCUIT(CE Regulation not applied)
When the starter is activated and the engine is started, the operator releases the key switch to the ON
position.
Charging current generated by operating alternator flows into the battery through the Battery
relay(CR-1).
The current also flows from alternator to each electrical component and controller through the fuse
box.
1) OPERATING FLOW
AlternatorūIŬterminal I/connŭCN-1(2)Ů CPU Alternator power level
ŭCN-51(18)Ů,
Charging lampŭCN-53(7)Ů I/connŭCN-7(7)Ů cluster charging warning lamp
ŭCN-56(7)Ů

Alternator B+ terminal Battery relay (M8) Battery(+) terminal


Fusible linkŭCN-60(2)Ů
I/connŭCN-5(2)Ů I/connŭCN-40(2)Ů Fuse Box

2) CHECK POINT
Engine Key switch Check point Voltage

‫ ڸ‬- GND (Battery voltage)


‫ ڹ‬- GND (Battery relay)
‫ ں‬- GND (Alternator B terminal)
ON ON ‫ ڻ‬- GND (Alternator I terminal) 20 ~ 25V
‫ ڼ‬- GND CPU
‫ ڽ‬- GND CPU
‫ ھ‬- GND Cluster

Ɠ GND : Ground

4 - 11
CHARGING CIRCUIT(CE Regulation not applied)

4 - 12
4. HEAD LIGHT CIRCUIT
1) OPERATING FLOW
Fuse box (No.8) I/connŭCN-37(1)Ů Head light switchŭCS-39(6)Ů
Head light relayŭCR-13(4)Ů
Ɠ When Light switch ON
Head light switch ONŭCS-39(2)Ů Head light relayŭCR-13(3) Ɗ (1)Ů Ground
ŭCR-13(4) Ɗ (2)Ů
Head light ONŭCL-3(2)Ů
I/connŭCN-4(7)Ů Head light ONŭCL-4(2)Ů
I/connŭCN-7(9)Ů Cluster illumination LampŭCN-56(9)Ů

2) CHECK POINT

Engine Key switch Check point Voltage

‫ ڸ‬- GND (Fuse box)


‫ ڹ‬- GND (Switch power input)
‫ ں‬- GND (Switch power output)
STOP ON ‫ ڻ‬- GND (Relay input) 20 ~ 25V
‫ ڼ‬- GND (Relay coil)
‫ ڽ‬- GND (Relay output)
‫ ھ‬- GND (Head light)

Ɠ GND : Ground

4 - 13
HEAD LIGHT CIRCUIT

4 - 14
HEAD LIGHT CIRCUIT(CE Regulation not applied)
1) OPERATING FLOW
Fuse box (No.8) I/connŭCN-37(1)Ů Head light switchŭCS-39(6)Ů
Head light relayŭCR-13(4)Ů
Ɠ When Light switch ON
Head light switch ONŭCS-39(2)Ů Head light relayŭCR-13(3) Ɗ (1)Ů Ground
ŭCR-13(4) Ɗ (2)Ů
Head light ONŭCL-3(3)Ů
I/connŭCN-4(7)Ů Head light ONŭCL-4(3)Ů
I/connŭCN-7(9)Ů Cluster illumination LampŭCN-56(9)Ů

2) CHECK POINT

Engine Key switch Check point Voltage

‫ ڸ‬- GND (Fuse box)


‫ ڹ‬- GND (Switch power input)
‫ ں‬- GND (Switch power output)
STOP ON ‫ ڻ‬- GND (Relay input) 20 ~ 25V
‫ ڼ‬- GND (Relay coil)
‫ ڽ‬- GND (Relay output)
‫ ھ‬- GND (Head light)

Ɠ GND : Ground

4 - 15
HEAD LIGHT CIRCUIT(CE Regulation not applied)

4 - 16
5. WORK LIGHT CIRCUIT
1) OPERATING FLOW
Fuse box (No.9) I/connŭCN-37(2)Ů Work light switchŭCS-36(6)Ů
Work light switchŭCR-3(4)Ů
Ɠ When Light switch ON
Work light switch ONŭCS-36(2)Ů Work light relayŭCR-3(3) (1)Ů Ground
ŭCR-3(4) (2)Ů
I/connŭCN-7(10)Ů Cluster Work light ONŭCN-56(10)Ů
I/connŭCN-4(4)Ů I/connŭCN-10(2)Ů Work light ONŭCL-6(2), CL-5(2)Ů

2) CHECK POINT

Engine Key switch Check point Voltage

‫ ڸ‬- GND (Fuse box)


‫ ڹ‬- GND (Switch power input)
‫ ں‬- GND (Switch power output)
STOP ON ‫ ڻ‬- GND (Relay input) 20 ~ 25V
‫ ڼ‬- GND (Relay coil)
‫ ڽ‬- GND (Relay output)
‫ ھ‬- GND (Work light)

Ɠ GND : Ground

4 - 17
WORK LIGHT CIRCUIT

4 - 18
WORK LIGHT CIRCUIT(CE Regulation not applied)
1) OPERATING FLOW
Fuse box (No.9) I/connŭCN-37(2)Ů Work light switchŭCS-36(6)Ů
Work light switchŭCR-3(4)Ů
Ɠ When Light switch ON
Work light switch ONŭCS-36(2)Ů Work light relayŭCR-3(3) (1)Ů Ground
ŭCR-3(4) (2)Ů
I/connŭCN-7(10)Ů Cluster Work light ONŭCN-56(10)Ů
I/connŭCN-4(4)Ů I/connŭCN-10(3)Ů Work light ONŭCL-6(3), CL-5(3)Ů

2) CHECK POINT

Engine Key switch Check point Voltage

‫ ڸ‬- GND (Fuse box)


‫ ڹ‬- GND (Switch power input)
‫ ں‬- GND (Switch power output)
STOP ON ‫ ڻ‬- GND (Relay input) 20 ~ 25V
‫ ڼ‬- GND (Relay coil)
‫ ڽ‬- GND (Relay output)
‫ ھ‬- GND (Work light)

Ɠ GND : Ground

4 - 19
WORK LIGHT CIRCUIT(CE Regulation not applied)

4 - 20
6. CAB LIGHT CIRCUIT
1) OPERATING FLOW
Fuse box (No.10) I/connŭCN-37(3)Ů Cab light switchŭCS-24(6)Ů
Cab light relayŭCR-9(4)Ů
Ɠ When Light switch ON
Cab light switch ONŭCS-24(2)Ů Cab light relayŭCR-9(3) (1)Ů Ground
ŭCR-9(4) (2)Ů
I/connŭCN-6(5)Ů I/connŭCN-14(4)Ů
Cab light ONŭCL-8(rear), CL-10(RH), CL-9(LH)Ů

2) CHECK POINT

Engine Key switch Check point Voltage

‫ ڸ‬- GND (Fuse box)


‫ ڹ‬- GND (Switch power input)
‫ ں‬- GND (Switch power output)
STOP ON ‫ ڻ‬- GND (Relay input) 20 ~ 25V
‫ ڼ‬- GND (Relay coil)
‫ ڽ‬- GND (Relay output)
‫ ھ‬- GND (Cab light)

Ɠ GND : Ground

4 - 21
CABIN LIGHT CIRCUIT

4 - 22
7. WIPER MOTOR CIRCUIT
1) OPERATING FLOW
(1) Wiper motor switch ON
Fuse box (No.1) I/connŭCN-36(6)Ů Wiper motor relayŭCR-4(2) ‫( ׿‬6)Ů
Wiper switchŭCS-3(6) ‫( ׿‬2)Ů Ground
Wiper motor relayŭCR-4(4) ‫( ׿‬1)Ů
I/connŭCN-6(1)Ů I/connŭCN-13(1)Ů
Wiper motor operatingŭCN-21(1)Ů

(2) Auto - parking (When switch OFF)


Wiper motorŭCN-21(1)Ů OFF Fuse box(No.1) I/connŭCN-36(6)Ů
I/connŭCN-6(2)Ů I/connŭCN-13(3)Ů Wiper motorŭCN-21(3) ‫( ׿‬4)Ů
Wiper motor stop

2) CHECK POINT

Engine Key switch Check point Voltage

‫ ڸ‬- GND (Fuse box)


‫ ڹ‬- GND (Switch input)
‫ ں‬- GND (Relay)
‫ ڻ‬- GND (Relay coil)
‫ ڼ‬- GND (Relay input)
OFF ON 20 ~ 25V
‫ ڽ‬- GND (Relay)
‫ ھ‬- GND (Wiper power input)
‫ ڿ‬- GND (Wiper power input)
‫ ۀ‬- GND (Wiper motor)
‫ ہ‬- GND (Switch output)

Ɠ GND : Ground

4 - 23
WIPER MOTOR CIRCUIT

4 - 24
WIPER MOTOR CIRCUIT(CE Regulation not applied)
1) OPERATING FLOW
(1) Wiper motor switch ON
Fuse box (No.1) I/connŭCN-36(6)Ů Wiper motor relayŭCR-4(2) ‫( ׿‬6)Ů
Wiper switchŭCS-3(6) ‫( ׿‬2)Ů Ground
Wiper motor relayŭCR-4(4) ‫( ׿‬1)Ů
I/connŭCN-6(1)Ů I/connŭCN-13(1)Ů
Wiper motor operatingŭCN-21(1)Ů

(2) Auto - parking (When switch OFF)


Wiper motorŭCN-21(1)Ů OFF Fuse box(No.1) I/connŭCN-36(6)Ů
I/connŭCN-6(2)Ů I/connŭCN-13(3)Ů Wiper motorŭCN-21(3) ‫( ׿‬4)Ů
Wiper motor stop

2) CHECK POINT

Engine Key switch Check point Voltage

‫ ڸ‬- GND (Fuse box)


‫ ڹ‬- GND (Switch input)
‫ ں‬- GND (Relay)
‫ ڻ‬- GND (Relay coil)
‫ ڼ‬- GND (Relay input)
OFF ON 20 ~ 25V
‫ ڽ‬- GND (Relay)
‫ ھ‬- GND (Wiper power input)
‫ ڿ‬- GND (Wiper power input)
‫ ۀ‬- GND (Wiper motor)
‫ ہ‬- GND (Switch output)

Ɠ GND : Ground

4 - 25
WIPER MOTOR CIRCUIT(CE Regulation not applied)

4 - 26
CONTROLLER CIRCUIT

4 - 27
ELECTRICAL CIRCUIT FOR HYDRAULIC

4-28
MONITORING CIRCUIT

4-29

You might also like