FACON FB SERIES

1. The table below shows the formats of every register the PWS can access.
Register Type Format Range With the Device Type / Data Size
Register Aux. Address R/W
Input Relay WXnnnn nnnn=0-9984; (Must be 0 0 0 Word ü
or multiple of 8)
Output Relay WYnnnn nnnn=0-9984; (Must be 0 1 0 Word ü
or multiple of 8)
Internal Relay WMnnnn nnnn=0-9984; (Must be 0 2 0 Word ü
or multiple of 8)
Step Relay WSnnnn nnnn=0-9984; (Must be 0 3 0 Word ü
or multiple of 8)
Timer Present RTnnnn nnnn=0-9999 4 0 Word ü
Value
Counter RCnnnn nnnn=0-9999 5 0 Word ü
Present Value
Data Register Rnnnnn nnnn=0-65534 6 0 Word ü
Data Register Dnnnnn nnnn=0-65534 7 0 Word ü
Note 1: The Workstation can read up to 64 words in one read command.

2. The table below shows the format of every on/off location the Workstation can access. When you
specify the address of an On/off Block register, the Aux. address should be zero.
Relay Type Format Range With the Device Type / Data Size
Relay Aux. Address R/W
Input Relay Xnnnn nnnn=0-9999 0xC0 0 Bit ü
Output Relay Ynnnn nnnn=0-9999 0xC1 0 Bit ü
Internal Relay Mnnnn nnnn=0-9999 0xC2 0 Bit ü
Step Relay Snnnn nnnn=0-9999 0xC3 0 Bit ü
Timer Flag Tnnnn nnnn=0-9999 0xC4 0 Bit ü
Counter Flag Cnnnn nnnn=0-9999 0xC5 0 Bit ü
Note 2: An On/off block must start at an address that is 0 or a multiple of 8.
Note 3: You cannot specify On/off blocks to read Timer Flags and Counter Flags.

Hitech Electronics Corp.


www.hitech-america.com
page 1
3. Example of the connections between PWS & RS232C of FB-MC type:

3.1 Example of the connections between PWS & RS485 of FB-MC type:

4. P.L.C. & PWS setting:


Please set the communication parameters & the DIP-Switch as below:
A. P.L.C. Setting B. PWS- Setting
a.Communication Format :RS232C/RS485
b.Node Address :1
c.Transmission Speed :9600/19200 bps Set the Workstation's operating
d.Transmission Format :7-bit, even,1-bit parameters to match the PLC.

Hitech Electronics Corp.


www.hitech-america.com
page 2