PRIME

Solutions for AMI systems

Technology for energy efficiency


Telemanagement
Most utility distribution companies have developed and
implemented modernisation plans for their distribution
lines, with the aim of improving energy efficiency.

In some countries, these improvements are prompted


by regulations that make it compulsory to provide a
more intelligent network, covering such areas as power
generation control, improvements to the distribution
lines, remote metering and remote control of transformer
substations or the installation of smart meters.

A whole range of new possibilities has emerged in the area of


smart metering that were completely unimaginable with traditional
mechanical meters. The communications system offers benefits
in PLC (Power Line Carrier) communication over the electrical
network, at an optimised cost. Some of the most notable
features of these meters with telemanagement are that
they allow you remotely connect and disconnect power,
obtain consumption load profiles, remotely read meters
in real time and record network quality parameters.

In addition to the smart meters that communicate over the


electrical network, the main component of a system with
this type of communication is the concentrator. This is a
key component for the management of the entire network
of meters, connected to a distribution transformer. The
concentrator is responsible for communicating with both the
meters and the central services that receive all of the data
from each of the distribution company’s concentrators.

To ensure interoperability between the different actors and


existing applications, it is preferable to use open and public
standards, such as those established by PRIME Alliance.

PoweRline Intelligent Metering Evolution


PRIME promotes a public, open system with a non-proprietary
telecommunications architecture, that will shape new AMM features and enable
the construction of the new power grids of the future, i.e. the Smart Grids.

PRIME is based on OFDM multiplexing on the CENELEC-A band. The ultimate


goal of PRIME is to establish a full range of international standards that ensure
interoperability between the equipment and systems of different manufacturers.

PRIME © 2016 CIRCUTOR, SA — circutor.com — central@circutor.com


Telemanagement system
Benefits of the system
1. Billing process
The telemanagement system with PRIME PLC communications enables the
meter reading process to be controlled automatically, thus eliminating reading
errors and reducing the costs associated with managing meters.

2. Demand management
From the information received from the meters, the concentrator allows you to create
an accurate prediction of the energy demand in different time slots. This facilitates
the management of the generation capacity of power distribution companies.

3. Technical management
To facilitate the technical maintenance of installations, the system offers a number
of features, including the efficient control of technical losses and fraud-related
(non-technical) losses, the remote connection and disconnection of the end
user’s power supply, the option to perform a remote technical analysis of any
user’s electrical parameters - without the need for any physical intervention - and
the remote configuration of each customer’s contracted power. At the same
time, it allows you to obtain power quality data at each measuring point.

4. Complex tariff system


This latest generation of meters is capable of controlling flexible tariffs,
which measure power consumption in different periods. This allows power
distribution companies to design domestic contracts that will apply tariffs
based on the actual cost of the energy, allowing each customer’s tariff
to be remotely adjusted according to the needs of the market.

Ethernet
COMPACT DC Series
C
D
ct
pa
om

s
C

om
Cc
PL

CIRWATT B410RCP
Three-phase meter

CIRWATT B200RCP
Single-phase meter

PRIME © 2016 CIRCUTOR, SA — circutor.com — central@circutor.com


Compact concentrator
for telemanagement

Concentrator
COMPACT DC Serie

Purpose of a PLC concentrator


The main purpose of a PLC concentrator is to read the energy meters over the
electrical network and export that data to one or more computer systems that
are responsible for managing concentrators or, failing that, meters. The ability to
send the same data collected by the concentrator to different systems results
in faster billing, for example, as the measurements are obtained instantly.

Not only power distribution companies and operators of distribution lines can optimise
their procedures. Energy suppliers, energy service companies and even customers
themselves can benefit from obtaining their consumption data, because the system allows
them to know their consumption habits and optimise their tariff or contracted power.

The new needs of the market, in terms of features and functionalities, have led CIRCUTOR
to develop the third generation of PRIME concentrators, the COMPACT DC range.

PRIME © 2016 CIRCUTOR, SA — circutor.com — central@circutor.com


Functionalities and features of COMPACT DC
The COMPACT DC concentrator is normally installed in the
transformer substation, by mounting it on a DIN rail and
connecting it to the low voltage winding of the three-phase
system. This allows the meters to be remotely managed through
PLC communications, using the protocol standardised by
PRIME Alliance. All of the information recorded by the meters is
obtained using PLC. This information includes the load profiles,
daily or monthly summaries of consumption and even quality
parameters and any events that have occurred at the measuring
point. As well as obtaining the readings, the concentrator allows
you to manage the meter, either by changing the scheduled tariff
or operating the circuit breaker to configure a new contracted
power or disconnecting or reconnecting the power supply.

Design
COMPACT DC, the latest generation of PRIME PLC concentrators, offers a design
with smaller dimensions, making it suitable for most cabinets on the market, and new
features such as a built-in dual-SIM 3G modem with 4 digital inputs. Another notable
feature is that this is a compact solution in a single unit; telemanagement in distribution
centres with two transformers, or for dual voltage transformers (COMPACT DC 2 dual
concentrator). A 10 kV internal overvoltage protection device has been included in
the Ethernet port of all COMPACT DC models, providing protection for 1 minute. In
terms of the design of the enclosure, the COMPACT DC concentrator has a DIN rail
attachment and a complete LED light indicator system on the front which provides
quick and complete visual information about the overall operation of the concentrator.
The electrical connection is at the bottom, using standard removable terminals, thus
facilitating integration within the enclosure, both in terms of securing the unit and
accessing the wiring and routing the wires to conduits, terminals or circuit breakers.

LV Supervision system
The implementation of a telemanagement system allows you to find monitoring functionality provides a large amount of information
out information at the supply end and to interact with the measuring to the company that operates the grid, as well as controlling and
device. In this context of remote measurement and management of monitoring the LV network. Some of the most notable features of
the grid, we must not forget the transformer substation itself, which the LV Supervision System are:
does not normally have measurement systems that offer visibility
regarding the transit of energy through the distribution transformer, –– Energy balances (obtaining technical
the highest point of LV distribution lines. and non-technical loss rates)
–– Control of the load level of each transformer phase.
COMPACT DC concentrators have built-in units that monitor all –– Preventive monitoring of the network. This allows
of the distribution lines, this is called the LV Supervision System. any problems in the network to be detected before
This measurement module is a three-phase meter, which measures they affect and are reported by customers.
forward voltage and current through current transformers. This –– MV parameters calculated.

PRIME © 2016 CIRCUTOR, SA — circutor.com — central@circutor.com


PLC Communications
Ethernet
In terms of PLC communications, the concentrator has a passive
COMPACT DC Series
three-phase injection system, that injects the maximum power
permitted by standard EN 50065, by all 3 phases at once. In
addition to the three-phase injection, the concentrator can be
configured, via the web, to inject through one of the 3 phases.
This is used in cases where one of the phases interferes with the
communications of the other phases.
DC
pact
Com

s
m
co
LC
P

Models
The PRIME COMPACT DC range of concentrators is available in with 1-minute insulation. In transformer substations where
different models, depending on the needs of each installation. there is no need to monitor the network with a LV supervision
The most basic model is the COMPACT DC SBT which, as well system and a small-sized unit is required, the COMPACT DC
as featuring the PLC concentrator, includes the LV supervision BASIC model is the most suitable concentrator, which as well
system. In addition to the supervision system, the COMPACT as offering concentrator functionality, includes a 3G modem.
DC 3G concentrator comes with a built-in 3G modem. If the The most complete concentrator model is the COMPACT DC
concentrator needs to monitor any signals or external indicators, CIRWATT
2. This concentrator is the B410RCP
unit for transformer substations with
Three-phase meter
such as floor or fire detectors, door open sensors or MV isolator two transformers, as it offers two fully insulated PLC injection
status sensors, the most suitable model is the COMPACT systems, two LV supervision systems to monitor each three-
DC 4I concentrator, which, in addition to the LV supervision phase network and a module with 4 digital inputs.
system, comes with a module that has four 10 kV digital inputs

CIRWATT B200RCP
Single-phase meter

Applications
Like its previous versions, the COMPACT DC is used to
provide communication with energy meters with PRIME
technology, designed for measuring in LV networks and
exporting the information obtained by PLC to the utility
company’s higher reading and billing systems.

The COMPACT DC is normally installed on the


transformer substation, whether indoors or outdoors,
connected to the three-phase system’s LV winding.

Whoever operates the network, normally the power distribution


company, will manage the entire network of concentrators and,
at the same time, through these, all of the meters connected to
each of the LV networks. Communication with the meters and
concentrators is two-way, because the concentrator or network
operator sends requests to the meters and the meters send
automatic records to the concentrator and the central services.

PRIME © 2016 CIRCUTOR, SA — circutor.com — central@circutor.com


Technical features
Power supply circuit Rated voltage 88...276 Vac
Frequency 50/60 Hz
Consumption Compact DC 3G 10... 26 VA
Compact DC 4I 12... 27 VA
Compact DC SBT 7... 20 VA
Compact DC Basic 10... 26 VA
Compact DC 2 11... 19 VA
Installation category CAT III 300 V
PLC coupling circuit Rated voltage 127/220...230/400 Vac ±20%
Frequency 45...65 Hz
Modulation OFDM (PRIME)
Band CENELC A
Embedded PC Microprocessor 600 MHz
Memory Flash: 256 MB, SDRAM 128 MB
Consumption < 2.5 W
Communications port 1x Ethernet 10/100 Mbit,
insulated 10 kV for 1 minute
Operating system Linux 3.14
LV Supervision system Voltage measurement margin 127/220...230/400 Vac ±20%
Nominal current (In) .../5 A
Installation category CAT III 600 V
Frequency measurement margin 45...65 Hz
Active energy measurement Class 1
Reactive energy measurement Class 2
Impulse LEDs 1 impulse LED for
active energy: 20000 imp/kWh
1 impulse LED for
reactive energy: 20000 imp/kVArh
3G modem Type Quad band HSPA + HSPA/UMTS
(Compact DC 3G model) 850/900/1900/2100 MHz
Maximum output power UMTS/3G (Power class 3): 24 dBm
SIM Mini-SIM with dual bay
Antenna SMA female connector
Digital inputs No. inputs 4
(Compact DC 4I model) Type Short-circuit (Vout max 12.5 V, Imax 15 mA)
Insulation 10 kV for 1 minute
Build features Enclosure material Self-extinguishing V0 plastic
Protection degree IP 41
Dimensions Compact DC 3G 203 x 199.5 x 130 mm
Compact DC 4I 203 x 199.5 x 130 mm
Compact DC SBT 165 x 119.5 x 130 mm
Weight Compact DC 3G 1.08 kg
Compact DC 4I 1.08 kg
Compact DC SBT 0.865 kg
Compact DC Basic 0.865 kg
Compact DC 2 1.510 kg
Minimum cross-section of the cables Voltage and power measurement:1 mm2
Secondaries of the current
transformers: 2.5 mm2
Standards UNE-EN 61000-4-2:2010, UNE-EN 61000-4-3:2007,
UNE-EN 61000-4-4:2013, UNE-EN 61000-4-5:2007,
UNE-EN 62052-11:2004, IEC 61010:2010.

References
Type CodeDimensions (mm) LV Supervision 3G Modem Inputs Connection
system 2nd transf.
Compact DC 3G Q46010 203x120x130 • • - -
Compact DC 4I Q46020 203x120x130 • - 4 digital inputs
insulated 10 -
kV/1 min
Compact DC SBT Q46030 165x120x130 • - - -
Compact Q46040 165x120x130 - • -
-
DC Basic
Compact DC 2 Q46050 279x120x130 2 - 4 digital inputs
insulated 10 •
kV/1 min

PRIME © 2016 CIRCUTOR, SA — circutor.com — central@circutor.com


Energy meters for
residential applications

residential meters

B200RCP / B410RCP
Type 5 meters
Residential meters make up the bulk of the systems that
have to be controlled by power distribution companies.
The PRIME system provides a more effective solution
for the telemanagement of this kind of meter.

PRIME © 2016 CIRCUTOR, SA — circutor.com — central@circutor.com


Applications
CIRCUTOR has developed both the single-phase and three-phase meter with
PRIME communications, for residential power supplies below 15 kW.

The main features of these types of systems are as follows:

–– Measurement of active and reactive energy, with the ability to distinguish


between energy consumed and generated (4 quadrants).

–– It remotely collects information about energy consumption, eliminating the errors


associated with manual readings and eradicating the need to make estimates.

–– Inclusion of a circuit breaker with two main functions. Thanks to the first function,
the utility company can remotely disconnect and reconnect the power supply of any
customer. The second is used for power limitation, allowing the contracted power
to be configured in each meter. When the power consumed exceeds this value, the
meter itself will disconnect the electric supply. To restore it, it will be necessary to
perform a safety operation, which consists of opening the main switch, at which
point the meter instantly detects that the circuit is open and restores the supply.

–– The unit has an internal memory that allows a load curve to be logged, storing up to
three months, at an hourly rate. This information allows the utility company to know
the consumption habits and adapt its generation capacity to the actual demand.

Technical features
Single-phase B200RCP Three-phase B410RCP

Power supply circuit Rated voltage 230 Vac 3 x 230 / 230/400 Vac*

Consumption < 2 W ; < 10 V·A < 2 W ; < 10 V·A

Frequency 50 Hz 50 Hz*

Current Nominal current 10 A 10 A


measurement
Maximum current 60 A 100 A

Accuracy class Active energy EN 50470 - Class B / IEC 62053-21 (Class 1)

Reactive energy IEC 62053-23 - Class 2

Clock Accuracy (EN 61038) < 0.5 sec/day at 23 ºC

Cutoff relay Type Two-pole Three-pole

Models
Code Type Description

QB3C0 212-ES4A-B0B-17 Single-phase meter, with circuit breaker

QB3C3 212-ES4A-BFB-17 Single-phase meter, with circuit breaker and tariff indicator relay

QB4M0 410-QD1A-B0B-12 Three-phase meter with circuit breaker

QB4M1 410-QD1A-B3B-12 Thee-phase meter, with circuit breaker and tariff indicator relay

* Contact us for other models.

PRIME © 2016 CIRCUTOR, SA — circutor.com — central@circutor.com


Energy meters for
industrial applications
and SMEs

industrial meters

B410DP / B410TP
Type 3 and 4 meters
This PRIME telemanagement system provided by CIRCUTOR not
only offers a robust solution for residential meter management,
it also enables the integration of industrial direct and indirect
measurement meters for low voltage supplies above 15 kW.

10

PRIME © 2016 CIRCUTOR, SA — circutor.com — central@circutor.com


Applications
Although telemanagement systems were originally created to deliver effective
reading and management of residential meters, it is to be expected that during
the second phase, or even in the initial project, one of the objectives set was
to take advantage of all of the resources that had already been deployed to
integrate the industrial meters connected to the same low voltage network.

CIRCUTOR has integrated PRIME communications into the direct and indirect
measurement three-phase energy meters. By including these customers, complete
telemanagement of all supplies connected to a transformer substation is provided.
This way a more complete energy balance is achieved, because you not only have
readings from residential meters, but also from industrial meters, meaning that more
accurate information about technical and non-technical losses can be obtained.

Technical features
Three-phase B410DP Three-phase B410TP

Power supply circuit Rated voltage 3 x 230 / 400 Vac 3 x 127/220 V / 3 x 230/400 Vac*

Consumption < 2 W ; < 10 V·A < 2 W ; < 10 V·A

Frequency 50 Hz 50 Hz*

Current Nominal current 10 A 5A


measurement
Maximum current 100 A 10 A

Accuracy class Active energy EN 50470 - Class B / IEC 62053-21 (Class 1)

Reactive energy IEC 62053-23 - Class 2

Clock Accuracy (EN 61038) < 0.5 sec/day at 23 ºC

Battery Type Lithium

Service life > 20 years at 30 ºC

Models
Code Type Description
QB4N0 410-QD1A-B0B10 Direct measurement
QB8I0 410-QT5A-B0B10 Indirect measurement
* Contact us for other models.

11

PRIME © 2016 CIRCUTOR, SA — circutor.com — central@circutor.com


Accessories for
the telemanagement system

System accessories
CIRCUTOR has a complete range of accessories, ranging
from the current transformers used in industrial indirect
measurement meters, overvoltage protection that optimises
the service life of our equipment, protecting it against
electrical disturbances, components with 3G modems that
allow our concentrators to be integrated into communications
networks, the SoftWatt PRIME parameterisation software
which can be used to configure meters and the optical
head for local reading and downloading from the units.

SoftWatt
SoftWatt PRIME software is an application designed for utilities
and power distribution companies that allows all of the tariffing,
measuring and communications parameters of the meters
to be configured with the PRIME protocol. SoftWatt PRIME
is compatible with all PRIME units, whether single-phase or
three-phase. Among other features, the application includes:

—— Configuration of contracts, public


holidays and contracted power
—— Configuration of the circuit breaker and the display view.
—— Downloading of load curves, events and energy closes.
—— Configuration of transformation ratios in indirect units.
—— Power quality parameters.

12

PRIME © 2016 CIRCUTOR, SA — circutor.com — central@circutor.com


Overvoltage protection
The PSM-PLC family of overvoltage dynamic isolator, to isolate the protection
protection devices includes a complete element from the network when it ceases
range of compact type-2 transient to be effective. The PSM-PLC range is
overvoltage protection devices with composed of class II protection devices,
replaceable cartridges. It is especially with various discharge capacities: 20 kA
designed to provide full and effective and 40 kA, with an 8/20 µs curve. This
protection against transient overvoltages protection device can be installed in the
in the electrical network and particularly telemanagement cabinets, where the
for networks with PLC communication. concentrators and wireless communication
Adequate protection is achieved through components will be located, to protect
staging; adapting the levels of protection both their power supply and the
to the part of the device where they are concentrator's three-phase coupling.
installed and to the systems inside it.
These protection devices have a built-in

Models
Code Type Description
P437635000000 PSM20/400 2-pole overvoltage protection device.
P432785000000 PSM40/400 4-pole overvoltage protection device.

3G / GPRS modem router


SGE-3G is the CIRCUTOR modem router. It is designed to
communicate with PRIME concentrators and meters via the Ethernet
ports, RS-232 and RS-485. The modem's main feature is that it is
able to communicate with EDGE / HSDPA (High Speed Downlink
Packet Access), as well as enabling the connection to be configured
with either a static or dynamic IP (through DynDNS services). All
SGE-3G modem configuration is performed on its web site.

Code Type Description


Q30230 SGE-3G/GPRS modem router GPRS-3G modem router with Ethernet communication

Current transformers
CIRCUTOR provides a number of CIRCUTOR also offers an alternative solution
versions in its range of low voltage current to the transformers currently available, the
transformers, depending on the requirements new, more compact TRMC-X3 range (2.5
of the power distribution company. VA and 0.5S class), with indoor and outdoor
installation models, in which the three current
The standard transformers used for measurement transformers are arranged
official measurements are the TRMC 210 on a single mechanical support at a more
and TRMC 400, 10 VA and 0.5S (or 0.5) cost-effective price, offering easy assembly
class. CIRCUTOR has also developed the and optimising performance. All while
same range of transformers but with less maintaining the accurate measurements
power (2.5 V·A), guaranteeing the same which are characteristic of these devices.
accuracy but at a far more competitive price.
* See models in specific catalogue.

LOC optical reader


CIRCUTOR has an optical head which is an essential accessory
for the local reading or configuration of PRIME meters.
CIRCUTOR has two different models, depending on the type
of communication interface, whether RS-232 or USB.

Models
Q30301 LOC RS-232 optical reader
Q30302 LOC-USB USB optical reader

13

PRIME © 2016 CIRCUTOR, SA — circutor.com — central@circutor.com


Compact solutions
for indoor TS

Cabinets for TS telemanagement


CIRCUTOR provides a complete solution for telemanagement in transformer substations.
The cabinets contain two elements that are necessary for performing remote measuring
and management of the concentrator and meters connected to it. They also include
protection and measurement components that make the cabinet robust and reliable.

14

PRIME © 2016 CIRCUTOR, SA — circutor.com — central@circutor.com


Cabinets with PRIME telemanagement
The CMBT PRIME COMPACT CT range are indoor cabinets containing different
models of concentrators from the Compact DC range, all with the Low Voltage
Supervision System included. The possibility of selecting different models of the
compact DC concentrator allows us to add further features such as 3G remote
communication through an integrated internal modem, alarm status through digital
inputs or measurements from meters installed on two transformers on separate lines.
All models include protection against transient overvoltages, two-pole or three-pole, a
disconnectable test terminal block for measurements and thermal magnetic protection.

The cabinet is available in polyester with a cover (also suitable for outdoors) or in double-
insulated enclosures with transparent and hinged covers.

CMBT PRIME COMPACT CT components


—— Compact DC PRIME concentrator.
—— LV supervision system meter (integrated into the concentrator).
—— Overvoltage protection devices.
—— Disconnectable test terminal block with 10 elements.
—— 2 and 4-pole circuit breakers.
—— 3G modem (depending on model).
—— 4 digital inputs for alarms or statuses (depending on model).
—— Connections second transformer (depending on model).

Models
Code Type Enclosure Modem Concentrator Dimensions
Q5CD43 CMBT PRIME COMPACT CT 6 Polyester 3G COMPACT DC 3G 500x500x300
Q5BD43 CMBT PRIME COMPACT CT 6A Double-insulated 3G COMPACT DC 3G 810x270x170
Q5CB40 CMBT PRIME COMPACT CT 7 Polyester - COMPACT DC SBT 500x500x300
Q5BB40 CMBT PRIME COMPACT CT 7A Double-insulated - COMPACT DC SBT 810x270x170
Q5DE50 CMBT PRIME COMPACT CT 8 Polyester - COMPACT DC 2 750x500x300
Q5DE51 CMBT PRIME COMPACT CT 9 Polyester SGE-3G COMPACT DC 2 750x500x300
/ GPRS

15

PRIME © 2016 CIRCUTOR, SA — circutor.com — central@circutor.com


Compact
Solutions for
outdoor TS

Cabinets for TP telemanagement


CIRCUTOR has also developed as robust solution for the
telemanagement of pole-mounted transformers.

Similar solutions are integrated for outdoor cabinets as they are for the
indoor version, but with the option of adding an enclosure that includes the
measurement transformers, either for the TC 8.3 individual model or the compact
TRMC-X3 three-phase solution. A load-break switch can also be included.

16

PRIME © 2016 CIRCUTOR, SA — circutor.com — central@circutor.com


Cabinets with PRIME telemanagement
The CMBT PRIME COMPACT PT range consists of outdoor cabinets with
built-in Compact DC concentrators and low voltage supervision modules.
They also give you the option to install the above unit with a built-in 3G
modem, for remote communication with the telemanagement system.

They also include overvoltage protection devices and a disconnectable test terminal
block that allows you to access the terminals of the supervision system meter. The
cabinet has a second enclosure for the measurement of the low voltage supervision
system, which includes a busbar with copper bars and TRMCx3 compact three-
phase current transformers or individual TC 8.3 transformers in different sizes.

CMBT PRIME COMPACT PT components


—— Compact DC PRIME concentrator
—— LV supervision system meter (integrated into the concentrator)
—— Load-break switch.
—— 1 compact TRMCx3 transformer or three individual TC 8.3 transformers
—— Overvoltage protection devices
—— Disconnectable test terminal block with 10 elements.
—— 2 and 4-pole circuit breakers.
—— 3G modem (depending on model).

Models
Code Type Modem Concentrator Transformers Load- Dimensions
break
switch
Q51D630021 CMBT PRIME COMPACT PT 3 200 A 3G COMPACT DC 3G TRMCx3 200/5 A 4x250 A 1000x500x300
Q51D630042 CMBT PRIME COMPACT PT 3 400 A 3G COMPACT DC 3G TRMCx3 400/5 A 4x400 A 1000x500x300
Q51D630053 CMBT PRIME COMPACT PT 3 500 A 3G COMPACT DC 3G TC 8.3 500/5 A 4x630 A 1250x500x300
Q51B600021 CMBT PRIME COMPACT PT 4 200 A - COMPACT DC SBT TRMCx3 200/5 A 4x250 A 1000x500x300
Q51B600042 CMBT PRIME COMPACT PT 4 400 A - COMPACT DC SBT TRMCx3 400/5 A 4x400 A 1000x500x300
Q51B600053 CMBT PRIME COMPACT PT 4 500 A - COMPACT DC SBT TC 8.3 500/5 A 4x630 A 1250x500x300
Q51D630020 CMBT PRIME COMPACT PT 5 200 A 3G COMPACT DC 3G TRMCx3 200/5 A - 1000x500x300
Q51D630040 CMBT PRIME COMPACT PT 5 400 A 3G COMPACT DC 3G TRMCx3 400/5 A - 1000x500x300
Q51D630050 CMBT PRIME COMPACT PT 5 500 A 3G COMPACT DC 3G TC 8.3 500/5 A - 1000x500x300
Q51B600020 CMBT PRIME COMPACT PT 6 200 A - COMPACT DC SBT TRMCx3 200/5 A - 1000x500x300
Q51B600040 CMBT PRIME COMPACT PT 6 400 A - COMPACT DC SBT TRMCx3 400/5 A - 1000x500x300
Q51B600050 CMBT PRIME COMPACT PT 6 500 A - COMPACT DC SBT TC 8.3 500/5 A - 1000x500x300

17

PRIME © 2016 CIRCUTOR, SA — circutor.com — central@circutor.com


complete
telemanagement system

Industrial application

Ethernet

s
om
Cc
PL

CIRWATT B410TP
Indirect measurement CIRWATT B410DP
i
D C4 Direct measurement
A CT
MP
CO

Urban application

Ethernet

BT
DCS
ACT
MP
CO

18

PRIME © 2016 CIRCUTOR, SA — circutor.com — central@circutor.com


CIRCUTOR has developed a complete range of devices based on the PRIME
telemanagement system, offering compact solutions for the industrial, urban and rural
environments. Much of our efforts have been devoted to designing concentrators as
key components for the management of the system, offering the most suitable solution
for each operating environment. The main key to the success of this system is its
compact design, on a DIN rail, which makes it easy to install in any type of enclosure.

Although current legislation only covers the inclusion of supply points of


under 15 kW in telemanagement systems, CIRCUTOR has already opted
to propose broader solutions, making it possible for indirect measurement
meters for industrial installations to be included in the system.

CIRWATT B410RCP
Three-phase meter

s
om
Cc
PL

CIRWATT B200RCP
Single phase meter

Rural application

3G s
om
Cc
PL

CIRWATT B200RCP
3G Single phase meter
C
CTD
PA
COM

19

PRIME © 2016 CIRCUTOR, SA — circutor.com — central@circutor.com


PRIME
Solutions for AMI systems

Designed by: Image and Communications Department, CIRCUTOR, SA


+ information: info@circutor.com

www.circutor.com

CIRCUTOR, SA - Vial Sant Jordi, s/n


08232 Viladecavalls (Barcelona) Spain
Tel. (+34) 93 745 29 00 - Fax: (+34) 93 745 29 14
central@circutor.com

Code: C2Q023-02 CIRCUTOR, SA reserves the right to change any information contained in this catalogue.

You might also like