Smart and Economic Transformer Monitoring: Trafoguard
Smart and Economic Transformer Monitoring: Trafoguard
Smart and Economic Transformer Monitoring: Trafoguard
Trends&&Monitoring
Monitoring TRAFOGUARD® Features Benefits
TRAFOGUARD®
Risk of failures
Deregulation leads to requests to reduce costs by
best possible utilization of resources
| Extension of transformer operating times
| Ageing transformer population
| Occasional overload operation
Increasing demand for analysis systems (offline) and monitoring systems (online)
for high-voltage equipment such as power transformers
Safe Power Supply with lower risk of plant disruptions due to ageing and overload
when using monitoring systems
Transformer monitoring
Trends & Monitoring TRAFOGUARD® Features Benefits
Winding 34%
Tank 21%
Core 5%
OLTC 26%
Bushing 20%
Other 19.5%
Includes multiple answers
| Bushing | Accessories
| Oil pressure | Transformer oil conservator oil level
| Voltage | Humidity in transformer oil conservator
| Load current | On-load tap-changer oil conservator oil level
| Internal temperature of | Humidity in on-load tap-changer oil conservator
conductor | Neutral point leakage current
| Leakage current
| Tan δ
| Cos φ
| Voltage distribution
| On-load tap-changer
| On-load tap-changer position
| Number of switch operations | Active section
| Diverter switch switching time | Oil temperature
| Torque | Core temperature
| Motor current/voltage | Hotspot temperature
| Contact wear | Oil moisture content
| Oil temperature | DGA
| Ambient temperature | Press force
| Motor current index | Boiling temperature
| Oil moisture content | Ageing rate
| DGA (VACUTAP® only) | Service life consumption
| Flow-controlled relay oil flow | Overload capacity
| On-load tap-changer oil pressure | Amount of gas in Buchholz relay
| Insulating medium breakdown voltage | Gas increase rate in Buchholz relay
| Differential temperature of diverter switch - transformer Source: Cigre Round Table 2008,
market analysis MR/ 2011 | Buchholz relay oil flow
| Boiler oil pressure (hermetic transformer)
TRAFOGUARD® Erich Steindl © MR GmbH 13.03.2012 Page 5
Trends & Monitoring TRAFOGUARD® Features Benefits
TRAFOGUARD®
1971 1979 1988 1989 1997 1999 2001 2003 2007 2008 2009 2012
PQ systems
Measured values
| Top oil temperature
| Ambient temperature
| Load current
| Load voltage
| On-load tap-changer position
Calculated values
| Hotspot
| Calculation of remaining lifetime/ageing of the transformer
| Active power
| Number of hours on tap position
| Number of switch operations per tap
| Number of passages through zero position
U/I measurement – digital I/Os – analog I/Os – 4-20 mA – PT100 – DGA – etc.
Temperature Sensors
Maintenance Free
for OLTC &
Silicagel Breather
Main Tank
Winding~ and
Oil Thermometer
Digital Oil
Temperature
Sensors Automatic
Voltage
Regulation
Intelligent
Fan Control
Special Application
Motor Drive unit (PST, Generator)
SCADA Integration
TRAFOVISORTM
Network level
Station level Control room Remote
IEC61850
Ethernet
Station level RJ45
RJ45
TRAFOVISORTM
local
RS232
TRAFOSETTM
Configurator
DGA
Advanced Monitoring
Free inputs
DGA - General
| Concentrations of the dissolved
gases and oil moisture content are
read in by a sensor via analog
signals (limit values per gas and
event texts individually
configurable).
Measured values
| up to 9 gases
| Oil moisture content
Calculated values
| Total gas content in oil
DGA sensor
4…20mA
dig. States
General
DGA General
| Automatic voltage regulation
Cooling system control | Parallel operation according to
master/follower principle
Measured values
Automatic Voltage Regulation
| Load current (already included in
basic function)
On-load tap-changer | Load voltage (already included
in basic function)
Measured values
DGA | On-load tap-changer oil
temperature
Measured values
DGA | Bottom oil temperature
| 3-phase winding temperature
Cooling system control (analog 4…20mA)
| Maximum winding temperature
DGA
General
| Free Configurable
Cooling system control
| The “Free Inputs” function
package offers the possibility of
Voltage regulation configuring other signals
(analog, digital and
temperatures) outside the
predefined standard
On-load tap-changer
Measured values
| up to 40 free inputs.
Advanced monitoring
| limit values and event texts can
be configured individually.
Free inputs
TRAFOVISORTM
Network level
Station level Control room Remote
IEC61850
Ethernet
Station level RJ45
RJ45
TRAFOVISORTM
local
RS232
TRAFOSETTM
Configurator
TRAFOVISORTM
MR visualization software (supplied free of
charge)
| Visualization of all alarms and measured values
(online and history values)
| Free configurable graphs
(texts, colours, etc.)
| Current and historic data
| Display of all events in the event list
| Automatic synchronization between
TRAFOGUARD® and TRAFOVISORTM Software
| Connection between TRAFOGUARD® and
TRAFOVISORTM locally or via remote access
(e.g. Ethernet)
Flexible & economic - the perfect solution for Retrofit of an old transformer
o Major features are already implemented in the basic version
o Modular design allows you (only) to add what you need and save money
o Up to 40 free programmable Inputs/Outputs
Smart Design
o No additional hardware (e.g. Server) or software (for Analysis) needed. All recorded data are stored
on the device and can be accessed and analyzed with the Visualization Software from any other
location in the network via IP address
o Long-term memory of historical measured values (memory capacity > 30 years)
o Just one device for Scada and for analysis of Data
Additonal Values
o Increased transformer life time by reduction of the average temperature of the oil temperature
using the Predective Mode of the Cooling System Control Modul
o Reduction of maintenance efforts by extension of maintenance intervals for MR-OLTC´s
(OILTAP)
o Automatic Voltage Regulation can be integrated
MR System
o The MR portfolio includes most of the devices and sensors needed for a transformer
Monitoring
o MR delivers high quality products, which are perfect adjusted to each other
Your Contact