Product: EXCAVATOR
Model: 330C L EXCAVATOR CYA
Configuration: 330C L Excavator CYA00001-UP (MACHINE)
POWERED BY C-9 Engine
i01627464
Table 1
Required Tools
6V-9829 Cap As 1
NOTICE
Note: The fan motor speed must be set to the correct specification before performing this test. Refer to
Testing and Adjusting, "Fan Motor Speed (Hydraulic Oil Cooler) - Test and Adjust".
3. Release the pressure in the hydraulic system. Refer to Testing and Adjusting, "Hydraulic System
Pressure - Release".
Illustration 1 g00845980
Illustration 2 g00845985
4. Disconnect case drain hose (2) from case drain filter (3). Install 6V-9829 Cap As on the open fitting of
case drain filter (3) .
5. Place the end of drain hose (2) into the container in order to measure the case drain oil.
7. Place the machine controls at the following settings: AEC switch OFF and engine speed dial "10".
Reference: Refer to Testing And Adjusting, "Engine Performance - Test" for engine rpm settings.