Installation Manual
Caution
If branch pipe and field pipe sizing was an insufficient connection and selection, Never operate the rated capacity of air Conditioner.
Be sure to observe the installation manual attached to the optional branch pipe and the installation manual of outdoor unit . 2. Restrictions of piping length and high/low difference
1. Parts of Model A A
Outdoor unit
▶ Be sure to include shown below supplied parts tUnit : mm u First branch
A G A G Y-branch
Gas Side Header Liquid Side Header Installtion Manual Indoor unit
ID12.7 ID12.7 ID6.35 ID6.35 Header branch
ID15.88 ID15.88
ID9.52 ID9.52
A E A E Plugging tube (sealing)
ID19.05
ID12.7
C X C X
To downward indoor unit
B F B F
c d e c d e
ARBL054
H 50m
H 30m
OD19.05 ID15.88 ID12.7 OD12.7 ID9.52 3 D 4 D 5 D 3 D 4 D 5 D
B B
Insulation For Header L 100m L 70m
h 15m
h 12m
l 30m l 30m
ID12.7
ID15.88
ID15.88
ID6.35
ID9.52
ID6.35 Total piping length ≤ 220m Figure 1 Total piping length ≤ 100m Figure 2
ID19.05
ID9.52
ID12.7
ID28.58
ARBL104
OD28.58 ID25.4 ID22.2 OD12.7 ID9.52 Permissible values
Item
Insulation For Header Figure 1. Figure 2.
1 each for gas/liquid sides 3/4 branches Farthest piping length 100m 70m
Length
Farthest piping length after first branch (ℓ) 30m 30m
Gas Side Header Liquid Side Header
ID12.7 ID15.88 ID6.35 ID9.52 ID9.52
High/Low High/Low difference in indoor/outdoor section(H) 50m(40m)* 30m(20m)*
ID12.7 ID6.35
difference High/Low difference in indoor/indoor section(h) 15m 12m
ID15.88
ID12.7
ID19.05
※ If the outdoor unit is lower than indoor unit, a parenthesized passage is permissible value.
ARBL057
OD19.05 ID15.88 ID12.7 OD12.7 ID9.52
Header Y-branch
Y 분지, Header
헤더 branch
분지,
Y-branch
Y 분지, 헤더 branch
분지,
P/NO : 3850A20490C
Insulation for header
4. Selection of pipe diameter and header branch 5) 6)
Sealing tape(Local contents)
Table 1. Refrigerant pipe diameter from branch Table 2. Between branching and Indoor unit
to branch (Fig1.-A, B, C) (Fig1.-a, b, c, d, e)
Downward Indoor unit total capacity Liquid pipe Gas pipe Insulation for header
Liquid pipe Gas pipe
[kW(Btu/h)] (mm) (mm) Indoor Unit capacity [kW(Btu/h)] Plupping tube
[mm(inch)] [mm(inch)] Field piping insulation Insulation for
~8.3(28,300) Ø9.52(3/8inch) Ø15.88(5/8inch) (Local contents) enclosed piping
~4.0(13,600) Ø6.35(1/4inch) Ø12.7(1/2inch)
~17.8(60,700) Ø12.7(1/2inch) Ø19.05(3/4inch)
~9.0(30,700) Ø9.52(3/8inch) Ø15.88(5/8inch)
~27.9(95,200) Ø12.7(1/2inch) Ø25.4(1inch)
H 30m
3 D 4 D 5 D 3 D 4 D 5 D
B B
L 100m L 70m B
h 15m
h 12m
l 30m l 30m
b b
C a 2 C a 2
1 D D 1 D D
To outdoor unit
5. Installation of header branch Plugging Tube
1) For sample. 7 branch A 3)
Horizontal plane ⑥ Always use a non-oxidizing brazing material for brazing the parts. If a non-oxidizing brazing material is not used, It could cause
To outdoor unit
clogging or damage to the compressor unit.
To indoor unit
Plugging tube
P/NO : 3850A20490C