Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Current Date: 11/19/2019 7:20 PM

Units system: SI
File name: D:\PEP Cemara Jatibarang\CMBA-10-A4-CA-002 Calculation for Gas Compressor Shelter\@FOR PRINT --- A2\RAM\Base Plate Shelter-
IDEAL.cnx\

Steel connections
Data
________________________________________________________________________________________________________________________

________________________________________________________________________________

Connection name : Fixed biaxial BP


Connection ID : 1
________________________________________________________________________________

Family: Column - Base (CB)

LY
Type: Base plate

GENERAL INFORMATION
Connector

N
O
I EW
EV
R
R
FO

MEMBERS
Column
Column type : Prismatic member
Section : H588X300
Material : A36
Longitudinal offset : 0 mm
Transversal offset : 0 mm

CONNECTOR
Base plate
Connection type : Unstiffened
Position on the support : Center
N: Longitudinal dimension : 850 mm
B: Transversal dimension : 550 mm
Thickness : 57 mm
Material : A36
Column weld : E70XX
Outer welds flanges only : No
D: Column weld size (1/16 in) : 25
Override A2/A1 ratio : No
Include shear lug : No
Support
With pedestal : No
Longitudinal dimension : 1000 mm
Transversal dimension : 700 mm
Thickness : 650 mm
Material : C30-37
Include grouting : Yes
Grout thickness : 25 mm
Anchor
Anchor position : Customized
Anchor coordinates:
Coordinate
Transverse Longitudinal
[mm] [mm]
------------------------------------
160.00 340.00
160.00 -340.00
-160.00 340.00
-160.00 -340.00

LY
160.00 0.00
-160.00 0.00
0.00 340.00
0.00 -340.00

N
160.00 170.00
-160.00 170.00
160.00 -170.00

O
-160.00 -170.00
------------------------------------
EW
Anchor type : L-bolt
Include lock nut : No
Anchor : 1"
Effective embedment depth : 450 mm
Total length : 565.53 mm
Material : F1554 Gr36
I

Fy : 0.248 kN/mm2
EV

Fu : 0.4 kN/mm2
Cracked concrete : No
Brittle steel : No
Anchors welded to base plate : No
R

Anchor reinforcement
Type of reinforcement : Primary
Tension reinforcement : No
Shear reinforcement : No
R
FO