Product Data Sheet

Edition 06, 2003


Identification no. GF01
SikaGrout® 215

Sikagrout® 215
Pumpable Non-Shrink Cementitious Grout
Construction

Description Sika Grout 215 if a non-shrink self levelling, cementitious grouting mortar with
extended working time to suit local ambient temperature.
Uses Sika Grout 215 is suitable for repairs to concrete structures and the following
grouting works with clearance of 10mm or more:
n Machine foundations
n Rail beds
n Columns in pre-cast construction
n Concrete anchors
n Bridge bearings
n Cavities
n Gaps
n Recesses
Characteristics / n Highly early strength
Advantages n High ultimate stregth
n Extended working time
n Dense, non-shrink
n Non-toxic, non-corrosive
n Chloride and iron free
n High final strength
Instruction for Use
Surface Preparation Surface Preparation
Concrete surfaces should be clean, sound and free from oil, grease, cement
laitance and all loosely adhering particles. Metal surfaces (iron and steel) should
be free from scale, rust, oil and grease. Absorbent substrates must be saturated
thoroughly, but there should be no standing water.
Mixing
The pre-mixed powder is added to water to suit the desired consistency. For
flowable consistency, approximately 4.2 litres of water per bag is required. Mix
mechanically for 2-3 mins with a slow speed drill (max. 500 RPM) until a smooth
even consistency is achieved.
Application
After mixing., allow the mortar to rest for a while, stirring lightly to ensure that air
displayed by the grouting is allowed to escape. When carrying out base plate
grouting, ensure that sufficient pressure head is maintained to keep mortar flow
uninterrupted. Make sure that the necessary formwork is firmly in place and kept
water light. Sika Grout 215 may be placed in thickness up to a maximum of 50mm
at one pour.Where large areas are to be placed, it is important to maintain a
continuous flow throughout. It is necessary to organize the work sequence
properly (manpower, materials, etc.) to ensure an uninterrupted flow. In such large
areas, Sika Grout 215 may also be pumped. A heavy duty diaphragm pump is
recommended for this purpose. Screw feed and piston pumps may also be used.
Specific Application
Grouting under base plate: Use flowable consistency
Grouting Anchor bolts: Use trowellable consistency
Grouting large volumes: For sections thicker than 50mm it is necessary to fill
the Sika Grout 215 with graded 10mm silt free aggregate to minimize temperature
rise. The quantity of aggregate should not exceed 1 part Sika Grout 215 by
weight.
For such mixes, a conventional concrete mixer and pump may be used.
Cleaning
Clean all tools and equipment with water immediately after use. Hardened mortar
can only be mechanically removed.

1 SikaGrout ® -215 1/2


Important Use Sika Grout 215 for repairs to concrete structure and grouting only.
Recommendations Minimum Gap: 10mm
Maximum Gap: 50mm
Minimum Application Temperature: 10 0C
At temperature lower than 20 0C setting time and stregnth gain will be slower.
Cure exposed mortar surface for at least 3 days with Anitsol E curing compound
or use other approved curing methods.
Coverage/Consumption Sika Grout 1.84 kg 25 kg 74 x 25 kg bag
(approx.) Water (Litre) 0.31 4.2 309
Volume Mortar 1 lit. 13.6 lit. 1 m3
Performance Flow (British Standard Cone):
280 - 320 mm after 3 minutes
260 - 300 mm after 30 minutes
Construction

(Keep on stirring slightly)


Comprehensive Strength in MPa (N/mm2):
(Water content: 4.2 liters/25 kg bag. Testing & storge at 25 0 C under water)
1 day : 38
3 days : 45
7 days : 55
28 days : 70
Technical Data

Form Powder
Color Grey

Bulk Density 1.64 kg/l

Wet Density 2.10 - 2.20 kg/l


Storage Condition Store in a dry place
Shelf Life 15 months when unopened
The information, and, in particular, the recommendations relating to the application and end-use of Sika
Legal Notice products, are given in good faith based on Sika’s current knowledge and experience of the products when
properly stored, handled and applied under normal conditions in accordance with Sika’s recommendations.
In practice, the differences in materials, substrates and actual site conditions are such that no warranty
in respect of merchantability or of fitness for a particular purpose, nor any liability arising out of any legal
relationship whatsoever, can be inferred either from this information, or from any written recommendations,
or from any other advice offered. The user of the product must test the product’s suitability for the intended
application and purpose. Sika reserves the right to change the properties of its products. The proprietary
rights of third parties must be observed. All orders are accepted subject to our current terms of sale and
delivery. Users must always refer to the most recent issue of the local Product Data Sheet for the product
concerned, copies of which will be supplied on request.

Sika Philippines, Inc.


Unit A & B
888 Marcos Alvarez, Ave. Tel.no. : 800 1818
Talon, Las Piñas City 1747 Fax. no : 806 2378
Philippines www.sika.com.ph

2 SikaGrout ® -215 2/2

You might also like