Download as pdf or txt
Download as pdf or txt
You are on page 1of 7

Table

Table Type
Type // Floor
Floor Type
Type

http://www.resco.co.jp/ryodenlift/
NAGOYA WORKS:1‐25 NISHIMATABEICHO.
MINAMI - KU. NAGOYA.AICHI 457 - 0835 JAPAN
TEL. : +81‐52‐618‐3260

Published: Nov e m b e r 2014


The contents of the document herein are subject to change without notice. p a g e 5
The Ryoden G-Series Dumbwaiter represents a more
advanced environment-friendly model which offers
improved operability, functionality, and safety, as well as
an automatic energy-saving mode which effectively
reduces power consumption.

Automatic energy-saving mode

●The energy-saving mode is automatically established


if the dumbwaiter is not operated within the prescribed
period of time. Compared to the past series, this
mode allows up to 53% of energy saving.
Normal dumbwaiter operation can be resumed by Cage operation is disabled by a switch when the
pressing the Energy-saving mode release button. door is open. A more reliable forced locking type

has also been adopted.

〈Energy-saving mode release button〉

p a g e 1 p a g e 2
operating panel

1.3 2.5

1.7 3.0
Operating panel

2.8 4.6

p a g e 3 p a g e 4
on handcarts into the car.

operating panel

5.7 8.4

6.8 10.0

Operating panel

7.7 15.1

p a g e 5 p a g e 6
Op ti o n s Ryoden G-Series Dumbwaiter
Specifications Table
Basic specifications
Cage lamp (LED) Table Type Floor Type
Option Item
RT RL
Cage lighting ensures Application Small freight items ● ●
that delivered items
(even small items) are Power supply 3-phase 200 VAC, 50/60Hz * Power transformer is option. ● ●
More efficient operability to clearly visible in dark Control format Inverter control ● ●
environments. Energy-saving Automatic energy-saving mode ● ●
facilitate ease of use * This lighting does not
Drive format Traction format ● ●
apply to some models.
For details, please contact Operation format Mutual-floors operation format (SEN) ● ●

Convenience
Ryoden.
Number of stops 2 to 8 stops ● ●
Max. 15m ● ●
UP/DOWN distance
From 15m to 30m ○ ○
45m/min ● -
Operation STOP & parking function Power service door Rated speed Load capacity: 200, 300kg = 45m/min - ●
Load capacity: 500kg = 23m/min - ●
This function locks all Both the service and Service door: manual upper/lower bi-parting doors ● ●
doors when an operation cage doors can be Door format
STOP status exists, opened simultaneously by
Cage door: power upper/lower bi-parting doors ● ●
thus preventing pressing a button. The Communication format Interphone: hand-free / press & talk (selectable) ● ●
mischievous operations, optional remote control Auto announce ● ●
etc. function can also be used
for increased
Cage position indicator lamp ● ●
Signal functions
convenience. An optional Error code indicator lamp ● ●
function which DOOR OPEN warning (buzzer, announcement) ● ●
automatically opens the
doors when the cage
Service door lock ● ●
arrives is also available. Service door switch ● ●
Cage door gate switch ● ●
Additional cage shelf board Return-to-reference-floor function Safety equipment Cage overrun limiting switch ● ●
AST system ● ●
An additional shelf This function automatically Emergency Stop button ● ●
board can be added or returns the cage to a specified
removed according to floor after its contents have
Overload alarm unit ● ●
the sizes, etc., of the been delivered. In systems ● : Basic specifications ○ : Optional (additional fee) specifications
items being delivered. where the transport direction is
* RT type only always the same, this function
eliminates the need to recall Specifications table
the cage, thus increasing
Table Type Floor Type
operation efficiency. A learning Item
function can also be added to RT RL
increase efficiency in systems Painted steel plate ● ●
with frequent-stop floors. Jamb
Stainless steel hairline ○ ○
Table Stainless steel hairline ● -
Painted copper plate - ●
Stainless steel construction Threshold
Stainless steel hairline - ○
Option
Sealed plastic sheet (splash-proof) ● ●
Rust-resistant stainless Operating panel
Stainless steel hairline face plate ○ ○
steel is used at
decorative surfaces. Painted copper plate ● ●
Service door
Equipped for better This also contributes to Stainless steel hairline ○ ○
a sanitary environment Ceiling and walls: painted copper plate ● ●
cleanliness which is ideal for
restaurant kitchens, etc. Ceiling and walls: stainless steel hairline ○ ○
* Standard construction for Cage interior Cage floor: stainless steel hairline ● ○
the RT type's floor, shelf
Sanitary boards, and table.
Painted and checkered steel plate for floor
Shelf boards: stainless steel hairline




Painted copper plate ● ●
Cage door
Stainless steel hairline ○ ○
Operation STOP switch (with parking function) ○ ○
Service door lock Return-to-reference-floor function ○ ○
Option
Cage shelf board addition (1 shelf) ○ -
Service functions
The service door can be Power service door ○ ○
locked by a dedicated Service door lock ○ ○
key.
For increased Cage, weight emergency stop unit ○ ○
● : Basic specifications ○ : Optional (additional fee) specifications
operation safety

Safety

p a g e 7 p a g e 8
The operating panel is shown in the horizontally oriented type for shutdown (4).
Talk indicator Call indicator
Energy-saving
Talk button Call button Floor indicator mode release
End button Error code display Stop button button
Volume button UP/DOWN indicator

Operation
Description
Operation of
each section
on the operating panel
Speaker Service Pin
indicator microphone
Station indicator
Door-close
Station selective button indicator Sending/Calling button

Interphone Operation Section Indicator Section Dumbwaiter Operation Section

Automatic energy-saving mode


The operation panel's indicator lamps are switched OFF and the energy-saving mode (control power OFF) is automatically established if
the dumbwaiter is not operated within 10 minutes after the Service indicator lamp switches OFF.
To resume dumbwaiter operation from this status, simply press the Energy-saving mode release button.
* The energy-saving mode is disabled when an error is active (when an error No. is displayed)
* The energy-saving mode is automatically established when the dumbwaiter is not in use, even if the interphone is in use or a standby status exists.

Operation of Each Section on the Operating Panel


1 Dumbwaiter operation section
Item Function
Sending/Calling button ● Calls or sends the car.
(your floor is indicated in yellow.) ● The target floor name in the indicator section flickers when registered.
● Stops the car when the car senses an error during operation.
Stop button
● The“E0”lamp in the error code display turns on while the button is pressed.
2 Indicator Section
Item Function
: Indicates the car is upward.
Travel indicator (orange)
: Indicates the car is downward.
ON : Indicates the name of the floor where the car is stopped.
Floor indicator (red)
Flicker : Indicates the target floor name while the car is traveling.
Error code display (red) E0 to E9 and EA, Eb : Indicates an error occurred.
Door-close indicator (green) ●Indicates that the service door and car door are fully closed.
Service indicator (yellow) ●Indicates that the service door is open, or that the car is in operation.
3 Interphone operation section
Item Function
Station selective button ●Talk with the target floor.
(indicator: red) ●The indicator turns on when the station is selected.
●Sounds in tremolo on the selected floor. (This button also allows you to call the selected floor by voice.)
Call button (indicator: red)
●The indicator turns on while the call button is pressed.
●Switches the talk mode from hands-free to press-talk.
Talk button (indicator: red) ●The indicator turns on in press-talk mode. (The indicator turns off in hands-free talk mode.)
●The indicator turns on when the interphone is in use in an area other than your station.
End button ●Ends talking.
●Adjust the volume of the call, talk, and auto announcement sound to one of three levels,
Volume button
in the order of low R medium R high.
Speaker ●Sounds call, talk, and auto announcement.
Pin Microphone ●Picks up voices. (The microphone is highly sensitive and does not require proximity during talking.)

WORKS NOT INCLUDED IN INSTALLATION CONTRACT NOTES


1.THE CONSTRUCTION WORKS OF HOISTWAY AND MACHINE ROOM. 1.VOLTAGE FLUCTUATION SHAL BE WITHIN +5%∼-10%
2.HOLES OF MACHINE ROOM FLOOR AND OPENINGS OF EACH FLOOR. 2.THE FOLLOWING CONDITIONS ARE REQUIRED FOR MAINTAINING THE PREDETERMINED PERFORMANCE.
3.MACHINE ROOM ENTRANCE.  (1)ENSURE THAT A 0℃ TO 40℃ TEMPERATURE IS MAINTAINED IN THE MACHINE ROOM AND THE UP/DOWN PASSAGEWAY,
4.OPENING FOR CARRYING CONTROL PANEL AND MACHINE,AND THEIR POURING. WITH THE AVERAGE MONTHLY HUMIDITY NOT EXCEEDING 90%, AND THE AVERAGE DAILY HUMIDITY NOT EXCEEDING 95%.
5.PIT WATERPROOF WORKS.  (2)MOISTURE SHOULD BE BELOW 90% ON A MONTHLY AVERAGE AND BELOW 95% ON A DAILY AVARAGE.
6.WIRINGS FOR POWER SUPPLY INCLUDING EARTHING TO POWER RECEIVING BOX IN MACHINE ROOM.  (3)MACHINE ROOM AND THE HOISTWAY SHOULD BE FREE OF DUST OR HARMFUL GAS.
7.WIRING FOR SIGNAL POWER SUPPLY TO POWER RECEIVING BOX IN MACHINE ROOM. 3.THE TUBE APPARATUSES FOR ELECTRICITY OR WARTER SUPPLY SHALL NOT BE BURIED INTO HOISTWAY WALL.
8.ILLUMINATION EQUIPMENT WORKS IN MACHINE ROOM AND ELECTRIC OUTLET FOR INSPECTION.
9.IF A GROUND FAULT INTERRUPTER IS USED AS THE CIRCUIT BREAKER,SET THE CURRENT SENSITIVITY TO 100 mA OR GREATER.

p a g e 9 p a g e 10
Table
Table Type
Type // Floor
Floor Type
Type

http://www.resco.co.jp/ryodenlift/
NAGOYA WORKS:1‐25 NISHIMATABEICHO.
MINAMI - KU. NAGOYA.AICHI 457 - 0835 JAPAN
TEL. : +81‐52‐618‐3260

Published: Nov e m b e r 2014


The contents of the document herein are subject to change without notice. p a g e 5

You might also like