DESIGN OF COLUMN

L.D.COLLEGE OF ENGINEERING

ME CASAD 2013-2014
KAMIL SHAIKH ROLL NO 9115516

RITESH ROHIT ROLL NO 511017

CHECK FOR LONG COLUMN L/D OR L/B 15>12

Pu Mx Mz
Max Fy 990.636 2.419 24.584
KN KN-M KN-M

L 7000 mm
SIZE OF COLUMN b 300 mm
D 400 mm
Fck 30 N/mm2
Fy 415 N/mm2

As a firat trial assume the reinforcement percentage


pt = 1.2 %

pt/fck = 0.04

Pu/(fck*b*D) = 0.003

For X direction d'/D = 0.05 from the graph of Pu/(d'/d) vs d'/D ref.SP 16

refer chart from SP-16

Mu/(fck*b*D2) = 0.07
Mux1 = ### Kn-M

For Z direction d'/D = 0.05

refer chart from SP-16

Mu/(fck*b*D2) = 0.07

Muz1 = 75600 Kn-M

Calculation of Puz

refer chart-63 from SP-16

Puy/Ag = 17

Puy = 204000 KN

Pu/Puz = 0.005

Mx/Mux= 0.000

Mz/Muz= 0.000

referring to chart-64 from SP-16 ,


Permissible value of Mx/Mux corresp.
to the above value of Mz/Muz & Pu/Puz

Mx/Mux= 1 SECTION IS OK

Assume % steel is ok

Area of steel As = 144000 mm2

Assume dia of bars 24 mm

Area of bar 452.376 mm2

Nos of bars 320 Nos


/(d'/d) vs d'/D ref.SP 16