Download as pdf or txt
Download as pdf or txt
You are on page 1of 20

Domestic Air Conditioner

SERVICE MANUAL

Models
HWR10XC6

Part number: AC-8888-134

Features

Top-Discharge Air Flow


Ultra Quiet Operation
Safty Power Cord
EnvicoCleanTM Coil
Easy-Access Washable Filter
Digital Display&Timer

Serial Number: Version:00.00 Edition: 2005-12-1


Domestic Air Conditioner Model: HWR10XC6

Content

1、 Product Code Illumination And Series introduction ---------------------------- 2


2、 Features -----------------------------------------------------------------------------------------3
3、 Specifications -------------------------------------------------------------------------------- 4
4、 Safety and Precaution -----------------------------------------------------------------------5
5、Warning and Cautions ----------------------------------------------------------------------6
6、Net Dimention ---------------------------------------------------------------------------------7
7、Installation and Accessory Parts -------------------------------------------------------8
8、Parts and Functions -----------------------------------------------------------------------10
9、Abnormity Diagnose -------- ---------------------------------------------------------------13
10、System Flow Chart -----------------------------------------------------------------------14
11、Circuit Diagram ----------------------------------------------------------------------------15
12、Maintenance Service and Trouble Shooting -----------------------------------16
13、Wiring Diagram --------------------------------------------------------------------------18
14、Exploded View and Parts Lists -----------------------------------------------------19

1
Domestic Air Conditioner Model: HWR10XC6

Product Code Illumination And Series Introduction


1.Model identification:

H W
A B C D E F G

A: Abbreviation of Haier
B: Abbreviation of Window
C: R-Remote Control
F-Mechanical Control
D: Nominal cooling capacity(BTU/h) with the first two numbers based on one
thousand unit
E: The type of power supply
X: 115V/60HZ
V:208/220V/50HZ
F: Function code
C-Cooling only
H-Heating pump
E-Electric aided heating
G: Design code

E SA
A B C D
A: Abbreviation of Energy Star
B: No meaning
C: Nominal cooling capacity(BTU/h) with the first two numbers based on one
thousand unit
D: Design code

Examples:
HWR10XC6
It represents remote contrl window air conditioner.Cooling capacity is 10000BTU/h and
the power supply is 115V /60Hz.

2.Standard situation/conditions
Indoor air state outdoor air state
No. Operating condition
D.B.℃ W.B.℃ D.B.℃ W.B.℃
1 Nominal cooling 26.7 19.4 35 23.9
2 Nominal heating / / / /
Nominal electrical
3 / / / /
heating

2
Domestic Air Conditioner Model: HWR10XC6

Specifications:
Item UNIT HWR10XC6
Cooling capacity BTU/h 10000
Heating capacity BTU/h /
Power supply 1PH/115V/60Hz
Power input W 1020
Cooling Running current A 9.0
EER BTU/(hW) 9.8
Power input W /
Heating Running current A /
COP BTU/(hW) /
Indoor side dB(A) 56/54/52
Sound Level
Outdoor side dB(A) /
Height mm 347
Case Width mm 500
Depth mm 450
Height mm 445
Packaging
Width mm 570
dimensions
Depth mm 494
Net lbs 64
Weight
Gross lbs 68.5
Type Rotate
Model 44R261AG-AJS
Compressor
Running cap. for comp. µF 60uf/250VAC
Starting method PSC
Heating side Psig 380
Pressure
Cooling side Psig 170
Model R22
Refrigerant
Charge kg 0.49
indoor unit Acentric fan
Type
outdoorunit Axial fan
Fan indoor unit r/min 1300±30/1200±40/1100
Fan
±30
speed
outdoorunit r/min /
Air volume CFM 235
Moisture removal Pints/hr 3.0
Exchanging pipe type/ diameter mm Evaporator:ф7
condenser:ф7
Fin material Hydrophile aluminum foil

3
Domestic Air Conditioner Model: HWR10XC6

Safety and Precaution

4
Domestic Air Conditioner Model: HWR10XC6

Warning and Cautions

5
Domestic Air Conditioner Model: HWR10XC6

Net Dimention

347
500 450

6
Domestic Air Conditioner Model: HWR10XC6

Installation and Accessory Parts

7
Domestic Air Conditioner Model: HWR10XC6

Installation and Accessory Parts

O N/ O FF

MO DE SPEE D TI ME R

TEM P/ TIM E

Remote “ CR2025“ battery


control

Model: HWR10XC6

8
Domestic Air Conditioner Model: HWR10XC6

Installation and Accessory Parts

HWR08XC5,HWR10XC6
ESA3065, ESA3085

HWR08XC5, ESA3065, ESA3085


HWR10XC6

13
16
1
20
4
5
8

9
Domestic Air Conditioner Model: HWR10XC6

Installation and Accessory Parts

10
Domestic Air Conditioner Model: HWR10XC6

Installation and Accessory Parts

11
Domestic Air Conditioner Model: HWR10XC6

Parts and Functions

12
Domestic Air Conditioner Model: HWR10XC6

Abnormity Diagnose
1. Sensor diagnose: 2 seconds after the sensors open circuit or short

circuit, the unit will turn off automatically and the LED will show E0 until

the sensors resume.

2. Keystroke circuit error diagnose: When power on for the first time, the

PCB will check the keystroke circuit, if the sampling value is different with

the theory value, the LED will show E1, which means failed keystroke

circuit. The keyboard is locked and so invalid, but the remote control is

working normally.

13
Domestic Air Conditioner Model: HWR10XC6

System Flow Chart

Indoor Outdoor
heat exchanger heat exchanger

Compressor

Capacillary tube

Cooling

14
Domestic Air Conditioner Model: HWR10XC6

Circuit Diagram

强板

弱板
注:1、R7为模式选择,
挂高为四模式,
不挂高为两模式。 R212K
2、R8为风速档数选择,
挂高为三挡,
不挂高为两挡。
3、R14,R15为华氏/摄氏选择,
挂高为摄氏,
接地为华氏。 R222K +5V

R302K DQ4
DQ2 DQ1 DQ3
+5 9012
9012 9012 9012
R312K
C9 R15
C10
10k
100UF/16V
104

10

5
CN3
R9
15
1K C15 CN20
14 L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 L1
13 15 LED1
R14 C5 C6
12 102 14
100UF/16V
11 104 13






 



















 







 
























 












10K
10 12
IC1TMP86C807
9 11

1
4
3
9
8
7
6
2
1 28
8 VSS P37 10
CX1 2 27 GFABCEDH
7 XIN P36 9
3 26
6 XOUT P35 8
4M 4 25
5 TEST P34 7
5 24
4 VDDP33(AIN1) 6
6 23
3 P21(XTIN)
P32(AIN0) 5
7 22
2 P22(XTOUT)P31 4
8 21
1 /RESET P30 3
9 20
P20P12(/DVO) 2
10 19
P00(TXD)
P11(INT1) 1
11 18 R23 330
P01(RXD)
P10(/INT0)
12 17 R24 330
C30 P02(SCLK)P07 330
13 16 R25
102 P03(MOSI)P06
14 15 R26 330
P04(MISO)
P05(/SS)
×¢£ºÁ¬Ðø11¸ö102 R27 330
R28 330
R29 330
C17
102
+5V

+5
C20 C22
PB1
100U/16V
104 K1 K2 K3 K4 K5 K6 K7
+12
R11 R18560 R16 R38
Q1 2.2K 10K
1K
9012













R10





 

















 
















IC22003 2K
1 16 R19
A1 Q1
2 15 C11R17 R42 R41 R32 R33 R34 R35 R36 R37
A2 Q2 2.2K
3 14 104 10K
A3 Q3 1K 1K 1K 2K 2K 2K 3K 10K
+5 4 13
A4 Q4
5 12 +5V
R84.7k R12
22k A5 Q5 R39
6 11
A6 Q6
7 10 330
A7 Q7
R74.7K R13 8
22k 9
GND
VCC
REV C21 R40
C16104 3 10K
4.7UF/50V
VCC
2
GND
1
OUT

+12
+5
+5
JK3 JK2 JK1 JK4
C7
R43
R20 4.7UF/50V D1 D2 S1
5.1K C8
10K R410K R310K 4.7UF/50V
1
+5 RG1 7805 2 TRANS
1
C13C12 3 1
L Vout Vin
ZR1 C14
FUSE1 104104 D3 D4
0.1u/250V
R5 R6 4 3
C3 C4 C1 C2
+5 5.1K 5.1K +5
2

104

104 1000UF/25V
470UF16V
LOW
MID
HIGH
2
1

2
1

1
2

CN1 CN2
CN4 盘管温度 室温
S2 S3 S4 S5 COMPRESSORUV

L1

15
Domestic Air Conditioner Model: HWR10XC6

Maintenance Service and Trouble Shooting

Always unplug your air conditioner before cleaning.

The air filter behind the front grille should be checked and cleaned
at least once every 2 weeks or more often if necessary.
To remove:
1. Open the inlet grille downward by pulling out the top of the inlet grille.
2. Remove the air filter from the front grille assembly by pulling the air
filter up slightly.
o o
3. Clean the filter with warm, soapy water below 40 C(104 F).
4. Rinse and gently shake the water from the filter and let it dry before
replacing it.
DO NOT use your air conditioner without the air filter in place.

To clean the front panels or the cabinet DO NOT use harsh


chemicals, abrasives, ammonia, chlorine, bleach, concentrated
detergents, solvents or metal scouring pads. Some of these chemicals

16
Domestic Air Conditioner Model: HWR10XC6

Maintenance Service and Trouble Shooting


Trouble Shooting

If air conditioner does not operate:


●Check if unit is plugged in.The plug may have come loose.
●Check if the unit is in “off” mode.

●The fan control may be in “off” position.

Air from air conditioner is warm:


●The A/C setting may need to be raised.
●The temperature outside the room is below 65°F。The conpressor will not

cycle on if the temperature outside is below 65°F.

Ice formation on cooling coils:


●Outside temperature too cold .Set the unit on fan only setting to defrose ice.
●Lower temperature setting.Temperature setting may be too cold.

●Unit BTU may be too high for the room.

17
Domestic Air Conditioner Model: HWR10XC6

Wiring Diagram

0010556721
WIRING DIAGRAM
R: RED
W: WHITE
SIGNAL
B: BLACK RECEIVER
G: GREEN BOARD
POWER SUPPLY
GR: GRAY
BL: BLUE

IC1
CN20
OR: ORANGE
YL: YELLOW SENSOR

Y/G: YELLOW/GREEN B(NO RIBBED)


CN2
G CN3
W(RIBBED)

COM

UV NO

CN4
JK4-1
LIGHT
PROTECTOR
B

FUSE1
TRANSFORMER
FUSE (250V 3.15A)
C
COMPRESSOR
M TR
R S CN5 HI MED LOW N

R W
C HERM

CAPACITOR
FAN
GR R OR W BL
B
3 6 5 4 1 2

GR BL
R OR YL

FAN MOTOR M
NOTE:THE COMPONENT PART IN BROKEN LINE AREA ISN'T
AVAILABLE FOR THE UNIT WITHOUT UV-LIGHT FUNCTION. BL

Y/G

18
Domestic Air Conditioner Model: HWR10XC6

Sincere Forever

Haier Group
Haier Industrial Park, No.1, Haier Road

266101, Qingdao, China

http://www.haier.com

21