Parameter Settings Report (Program) 3/19/2020 4:26:50 PM

Program (Drive Selected / Connected):


Drive Type / Model: L1000A CIMR-L*4*0031***
Software: 7201

Project:
User:

Information Last Updated: 3/19/2020 4:23:24 PM

Default
Parameter Value Information Setting
A1 Initialization
A1-01 Access level 2 Advanced Level Access 2
*A1-02 Control method... [M] 7 Closed Loop Vector for PM Motor 2
A1-04 Enter password 0 0
A2 User Parameters
*A2-01 User parameter 1... [M] Not Mapped A1-02
*A2-02 User parameter 2... [M] Not Mapped b1-01
*A2-03 User parameter 3... [M] Not Mapped C1-01
*A2-04 User parameter 4... [M] Not Mapped C1-02
*A2-05 User parameter 5... [M] Not Mapped d1-01
*A2-06 User parameter 6... [M] Not Mapped d1-02
*A2-07 User parameter 7... [M] Not Mapped d1-03
*A2-08 User parameter 8... [M] Not Mapped d1-04
*A2-09 User parameter 9... [M] Not Mapped d1-26
*A2-10 User parameter 10... [M] Not Mapped E1-01
*A2-11 User parameter 11... [M] Not Mapped E1-04
*A2-12 User parameter 12... [M] Not Mapped E1-05
*A2-13 User parameter 13... [M] Not Mapped E1-06
*A2-14 User parameter 14... [M] Not Mapped E1-09
*A2-15 User parameter 15... [M] Not Mapped E1-13
*A2-16 User parameter 16... [M] Not Mapped E2-01
*A2-17 User parameter 17... [M] Not Mapped E2-04
*A2-18 User parameter 18... [M] Not Mapped E2-11
*A2-19 User parameter 19... [M] Not Mapped L1-01
A2-20 User parameter 20 Not Mapped -N/M-
A2-21 User parameter 21 Not Mapped -N/M-
A2-22 User parameter 22 Not Mapped -N/M-
A2-23 User parameter 23 Not Mapped -N/M-
A2-24 User parameter 24 Not Mapped -N/M-
A2-25 User parameter 25 Not Mapped -N/M-

DriveWizard iQrise for Windows (C) by Yaskawa America, Inc. 1/10

PDF created with pdfFactory Pro trial version www.pdffactory.com


Default
Parameter Value Information Setting
A2-26 User parameter 26 Not Mapped -N/M-
A2-27 User parameter 27 Not Mapped -N/M-
A2-28 User parameter 28 Not Mapped -N/M-
A2-29 User parameter 29 Not Mapped -N/M-
A2-30 User parameter 30 Not Mapped -N/M-
A2-31 User parameter 31 Not Mapped -N/M-
A2-32 User parameter 32 Not Mapped -N/M-
A2-33 User parameter Automatic registration 0 Automatic registration is unavailable(Totally user setting from 0
Function A2-01 toA2-32)
b1 Operation Mode Selection
b1-01 Speed Reference Selection 0 Digital operator 0
b1-02 Operation method selection 1 Control circuit terminal 1
b1-03 Stopping method 0 Deceleration to stop 0
b1-06 Digital Input Scan Selection 1 2 Scans 1
b1-08 Run command at programming 0 Cannot operate 0
*b1-14 Phase Turn Selection... [M] 1 Exchange the Phase turn (without PG only) 0
b4 Timer Function
b4-01 Delay-ON timer 0.0 sec 0.0 sec
b4-02 Delay-OFF timer 0.0 sec 0.0 sec
b6 Dwell Function
b6-01 Dwell frequency at start 0.0 % 0.0 %
b6-02 Dwell time at start 0.0 sec 0.0 sec
b6-03 Dwell frequency at stop 0.0 % 0.0 %
b6-04 Dwell time at stop 0.0 sec 0.0 sec
b7 Droop Control
b7-01 Droop control gain 0.0 % 0.0 %
b7-02 Droop control delay time 0.05 sec 0.05 sec
b8 Energy Saving
b8-01 Energy-saving mode selection 0 Disable 0
b8-16 Energy-saving coefficient Ki for PM 0.10 0.10
b8-17 Energy-saving coefficient Kt for PM 1.00 1.00
C1 Acceleration and Deceleration Times
*C1-01 Acceleration time 1... [M] 3.20 sec 1.50 sec
*C1-02 Deceleration time 1... [M] 3.00 sec 1.50 sec
C1-03 Acceleration time 2 1.50 sec 1.50 sec
*C1-04 Deceleration time 2... [M] 2.00 sec 1.50 sec
C1-05 Acceleration time 3 for motor2 1.50 sec 1.50 sec
C1-06 Deceleration time 3 for motor2 1.50 sec 1.50 sec
C1-07 Acceleration time 4 for motor2 1.50 sec 1.50 sec
C1-08 Deceleration time 4 for motor2 1.50 sec 1.50 sec
C1-09 Emergency stop time 1.50 sec 1.50 sec
C1-10 Accel/Decel time setting unit 0 0.01-second units 0
C1-11 Accel/Decel switching frequency 0.0 % 0.0 %
C1-15 Inspection Operation Deceleration Ramp 0.00 sec 0.00 sec
C2 S-Curve Characteristics
*C2-01 S-curve acceleration at start... [M] 2.20 sec 0.50 sec
*C2-02 S-curve acceleration at end... [M] 1.50 sec 0.50 sec
*C2-03 S-curve deceleration at start... [M] 1.50 sec 0.50 sec

DriveWizard iQrise for Windows (C) by Yaskawa America, Inc. 2/10

PDF created with pdfFactory Pro trial version www.pdffactory.com


Default
Parameter Value Information Setting
*C2-04 S-curve deceleration at end... [M] 2.00 sec 0.50 sec
*C2-05 Jerk below leveling speed... [M] 2.00 sec 0.50 sec
C3 Slip Compensation
C3-05 Output V Limit 0 Disable 0
C5 Speed Control (ASR)
*C5-01 ASR proportional (P) gain 1... [M] 8.00 3.00
C5-02 ASR integral (I) time 1 0.300 sec 0.300 sec
*C5-03 ASR proportional (P) gain 2... [M] 8.00 3.00
*C5-04 ASR integral (I) time 2... [M] 0.300 sec 0.500 sec
C5-06 ASR primary delay time constant 0.004 sec 0.004 sec
C5-07 ASR gain switching frequency 2.0 % 2.0 %
C5-08 ASR integral limit 400 % 400 %
C5-13 Speed Control Loop Proportional Gain 3 3.00 3.00
C5-14 Speed Control Loop Integral Time 3 0.300 sec 0.300 sec
C5-16 Speed Control Loop Delay time during 0.000 sec 0.000 sec
Position Lock
*C5-17 Motor Inertia... [M] 0.165 kgm2 0.010 kgm2
C5-18 Load Inertia ratio 1.0 1.0
C5-19 Speed Control Loop Proportional gain time 10.00 10.00
during Position Lock
C5-20 Speed Control Loop Integral time during 0.100 0.100
Position Lock
C5-50 Notch Filter Frequency 0 Hz 0 Hz
C6 Carrier Frequency
C6-03 Carrier frequency upper limit 8.0 kHz 8.0 kHz
C6-09 Carrier in tune 0 5kHz 0
C6-21 Inspection Operation Carrier Frequency 1 2 kHz fix 1
C6-23 Carrier Frequency During Initial Motor Pole 0 2 kHz fix 0
Search
C6-31 Rescue Operation 2kHz 0 C6-03 setting 0
d1 Frequency Reference
d1-01 Speed Reference 1 0.00 % 0.00 %
*d1-02 Speed Reference 2... [M] 15.00 % 0.00 %
*d1-03 Speed Reference 3... [M] 15.00 % 0.00 %
*d1-04 Speed Reference 4... [M] 3.00 % 0.00 %
*d1-05 Speed Reference 5... [M] 15.00 % 0.00 %
*d1-06 Speed Reference 6... [M] 61.50 % 0.00 %
*d1-07 Speed Reference 7... [M] 61.50 % 0.00 %
*d1-08 Speed Reference 8... [M] 61.50 % 0.00 %
d1-18 Speed Reference Selection Mode 0 Use Multi-Speed references d1-01 to d1-08 0
*d1-24 Inspection Operation Speed... [M] 30.00 % 50.00 %
d1-25 Rescue Operation Speed 10.00 % 10.00 %
d1-26 Leveling Speed 8.00 % 8.00 %
d1-28 Leveling Speed Detection Level 0.0 % 0.0 %
d1-29 Inspection Speed Detection Level 0.0 % 0.0 %
E1 Motor 1 V/f Pattern Characteristics
*E1-01 Input voltage setting... [M] 380 VAC 400 VAC
*E1-04 Max. output frequency... [M] 153 rpm 96 rpm
*E1-05 Max. voltage... [M] 380.0 VAC 0.0 VAC
*E1-06 Base frequency... [M] 153 rpm 96 rpm
E1-09 Min. output frequency 0 rpm 0 rpm

DriveWizard iQrise for Windows (C) by Yaskawa America, Inc. 3/10

PDF created with pdfFactory Pro trial version www.pdffactory.com


Default
Parameter Value Information Setting
E5 PM Motor Setup
*E5-02 Motor rated output for PM... [M] 10.70 kW 15.00 kW
*E5-03 Motor rated current for PM... [M] 25.5 A 26.6 A
*E5-04 Number of motor poles for PM... [M] 20 pole 12 pole
*E5-05 Motor armature resistance for PM... [M] 0.380 Ohm 0.378 Ohm
*E5-06 Motor d axis inductance for PM... [M] 6.10 mH 9.85 mH
*E5-07 Motor q axis inductance for PM... [M] 9.08 mH 14.79 mH
*E5-09 Generation voltage constant 1 fo... [M] 0.0 mV sec/rad 508.4 mV
sec/rad
*E5-11 Pulse generator home pulse compe... [M] 46.9 deg 0.0 deg
*E5-24 Generation voltage constant 2 fo... [M] 1583.4 0.0
mV/min-1 mV/min-1
F1 Simple PG V/f Setup
F1-01 PG constant 2048 PPR 2048 PPR
F1-02 PG feedback loss selection 1 Coast to Stop 1
F1-03 PG overspeed selection 1 Coast to Stop 1
F1-04 PG deviation selection 1 Coast to Stop 1
F1-05 PG rotation 1 Phase B leads with forward run command. 1
F1-06 PG division rate(PG pulse monitor) 1 1
F1-08 Overspeed detection level 115 % 115 %
F1-09 Overspeed detection delay time 0.0 sec 0.0 sec
F1-10 PG deviation level 10 % 10 %
F1-11 PG deviation time 0.5 sec 0.5 sec
F1-14 PG open-circuit detection time 2.0 sec 2.0 sec
F1-18 dv3 Detection Selection 10 10
F1-19 dv4 Detection Selection 128 128
F1-20 Hardware PGO Detection Enable/Disable 1 Enable 1
Selection
F1-29 DEV Detection Condition Selection 2 Always during Run 2
F1-50 Encoder Selection 0 EnDat 2.1/2.2 Serial + Sin/Cos 0
F1-51 PGOH detection level 80 % 80 %
F1-52 Serial Encoder Communication Speed 0 1M/9600bps 0
Slection
F1-63 PG-E3 R Track Selection 0 Disable 0
F1-66 PG-E3 Encoder Adjust1 0000 0000
F1-67 PG-E3 Encoder Adjust2 0000 0000
F1-68 PG-E3 Encoder Adjust3 0000 0000
F1-69 PG-E3 Encoder Adjust4 0000 0000
F1-70 PG-E3 Encoder Adjust5 0000 0000
F1-71 PG-E3 Encoder Adjust6 0000 0000
F1-72 PG-E3 Encoder Adjust7 0000 0000
F1-73 PG-E3 Encoder Adjust8 0000 0000
F1-74 PG-E3 Encoder Adjust9 0000 0000
F1-75 PG-E3 Encoder Adjust10 0000 0000
F1-76 PG-E3 Encoder Adjust11 0000 0000
F1-77 PG-E3 Encoder Adjust12 0000 0000
F1-78 PG-E3 Encoder Adjust13 0000 0000
F1-79 PG-E3 Encoder Adjust14 0000 0000
F1-80 PG-E3 Encoder Adjust15 0000 0000
F1-81 PG-E3 Encoder Adjust16 0000 0000
F3 Digital Input Card (DI-A3)

DriveWizard iQrise for Windows (C) by Yaskawa America, Inc. 4/10

PDF created with pdfFactory Pro trial version www.pdffactory.com


Default
Parameter Value Information Setting
F3-01 DI Option Input Mode Selection 0 BCD 1% 0
F3-03 DI Option Bit Size Selection 2 16 bit 2
F4 Analog Monitor Card (AO-A3)
F4-01 Terminal V1 Monitor Setting 102 Output frequency 102
F4-02 Terminal V1 Monitor Gain Setting 100.0 % 100.0 %
F4-03 Terminal V2 Monitor Setting 103 Output current 103
F4-04 Terminal V2 Monitor Gain Setting 50.0 % 50.0 %
F4-05 Terminal V1 Monitor Bias Setting 0.0 % 0.0 %
F4-06 Terminal V2 Monitor Bias Setting 0.0 % 0.0 %
F4-07 AO1 Option Output Level Selection 1 -10 to 10 V (11 bit signed) 1
F4-08 AO2 Option Output Level Selection 1 -10 to 10 V (11 bit signed) 1
F5 Digital Output Card (DO-A3)
F5-01 Terminal P1-PC Function Selection 0000 Closed: There is a run command present or the drive is 0000
outputting voltage
F5-02 Terminal P2-PC Function Selection 0001 Closed: Output frequency is zero 0001
F5-03 Terminal P3-PC Function Selection 0002 Closed: Output frequency equals the speed reference (plus or 0002
minus the value set to L4-02)
F5-04 Terminal P4-PC Function Selection 0004 Closed: Output frequency is less than or equal to the value in 0004
L4-01 with hysteresis determined by L4-02.
F5-05 Terminal P5-PC Function Selection 0006 Closed: Drive Ready 0006
F5-06 Terminal P6-PC Function Selection 0037 During frequency output (ON: During frequency output) 0037
F5-07 Terminal M1-M2 Function Selection 000F Not used 000F
F5-08 Terminal M3-M4 Function Selection 000F Not used 000F
F5-09 DO Option (DO08) Output Mode Selection 0 8ch Individual Output 0
F6 Option Card 1 Serial Communication
F6-01 Operation selection after communications 1 Coast to stop 1
error
F6-02 Selection of External Fault from 0 Always detect 0
Communication Option Board
F6-03 Stopping Method for External Fault from 1 Coast to Stop 1
Communication Option Board
F6-04 Trace Sampling from Communications Option 2.0 sec 2.0 sec
Board
F6-06 Torque Reference/Torque Limit Selection 0 Disable 0
from Communications Option Enable/Disable
F6-08 Comm Parameter Initialize Selection 0 Comm Parameters are not initialized due to A1-02. 0
F6-35 Node Address 0 0
F6-36 CANopen Communication Speed 6 500 Kbps 6
F6-80 Trace sampling setting 0 0
F6-81 ASR P gain selection (C5-01/PLC) 0 Use C5 parameter 0
H1 Multi-Function Digital Inputs
H1-03 Terminal S3 function selection 24 External fault, N/O Detect always, coast stop 24
*H1-04 Terminal S4 function selection... [M] 09 External baseblock (N/C) 14
H1-05 Terminal S5 function selection 03 Multi-step speed reference 1 03
H1-06 Terminal S6 function selection 04 Multi-step speed reference 2 04
H1-07 Terminal S7 function selection 05 Multi-step speed reference 3 05
H1-08 Terminal S8 function selection 0F Not used(Unused / when use it as a pass-through mode.) 0F
H2 Multi-Function Digital Outputs
*H2-01 Terminal M1/M2 Selection... [M] 0037 During frequency output (ON: During frequency output) 0050
H2-02 Terminal M3/M4 Selection 0051 Output Contactor Control 0051
*H2-03 Terminal M5/M6 Selection... [M] 0037 During frequency output (ON: During frequency output) 0006
H2-04 Terminal P1 Selection 0037 During frequency output (ON: During frequency output) 0037
H2-05 Terminal P2 Selection 000F Not used 000F
H3 Multi-Function Analog Inputs
*H3-01 Terminal A1 Signal Level Selecti... [M] 1 -10 to 10 V (11 bit signed) 0

DriveWizard iQrise for Windows (C) by Yaskawa America, Inc. 5/10

PDF created with pdfFactory Pro trial version www.pdffactory.com


Default
Parameter Value Information Setting
*H3-02 Terminal A1 Function Selection... [M] 14 Torque compensation bias 00
*H3-03 Terminal A1 Gain Setting... [M] 117.0 % 100.0 %
H3-04 Terminal A1 Bias Setting 0.0 % 0.0 %
H3-09 Terminal A2 Signal Level Selection 0 0 to +10 V 0
H3-10 Terminal A2 Function Selection 1F Not used. Enter this setting when not using the terminal or 1F
when using it in the through mode.
H3-11 Terminal A2 Gain Setting 100.0 % 100.0 %
H3-12 Terminal A2 Bias Setting 0.0 % 0.0 %
H3-13 Filter Avg time 0.03 sec 0.03 sec
H3-16 Terminal A1 Offset 0 0
H3-17 Terminal A2 Offset 0 0
H3-18 Terminal A3 Offset 0 0
H4 Multi-Function Analog Outputs
H4-01 Multi-Function Analog 1(Analog Terminal 102 Output frequency 102
Monitor Selection)
H4-02 Multi-Function Analog 1(Analog Terminal 100.0 % 100.0 %
Output Gain)
H4-03 Multi-Function Analog 1(Analog Terminal 0.0 % 0.0 %
Output Bias)
H4-04 Multi-Function Analog 2(Analog Terminal 103 Output current 103
Monitor Selection)
H4-05 Multi-Function Analog 2(Analog Terminal 50.0 % 50.0 %
Output Gain)
H4-06 Multi-Function Analog 2(Analog Terminal 0.0 % 0.0 %
Output Bias)
H4-07 Multi-Function Analog 1(Signal Level 0 0 to +10 V 0
Selection)
H4-08 Multi-Function Analog 2(Signal Level 0 0 to +10 V 0
Selection)
H5 MEMOBUS/Modbus Communications
H5-01 Station address 01 01
H5-02 Communication speed selection 3 9600 bps 3
H5-03 Communication parity selection 0 No parity 0
H5-04 Serial fault selection 3 Operation continued 3
H5-05 CE Detection Selection 1 Enabled 1
H5-06 Send wait time 5 ms 5 ms
H5-07 RTS control ON/OFF 1 Enabled 1
H5-09 CE detection time 2.0 sec 2.0 sec
H5-10 Output voltage monitor(Register No.25) unit 0 0.1V unit 0
H5-11 ENTER function selection of transmission 0 A constant is reflected and memorized when ENTER is input. 0
L1 Protection
L1-01 Motor protection selection 5 Motor protection for a PM motor with rated torque 5
L1-02 Motor protection time constant 1.0 min 1.0 min
L1-03 Motor Overheat Alarm Operation Selection 3 Coast to stop with timer 3
(PTC input)
L1-04 Motor Overheat Fault Operation Selection 1 Coast to stop 1
(PTC input)
L1-05 Motor Temperature Input Filter Time (PTC 0.20 sec 0.20 sec
input)
L1-13 Electronic thermal continues 1 Continue Electronic thermal 1
L2 Momentary Power Loss
*L2-05 Undervoltage detection level... [M] 380 VDC 350 VDC
L4 Frequency Detection
L4-01 Speed agreement level 0.0 % 0.0 %
L4-02 Speed agreement width 4.0 % 4.0 %
L4-03 Speed agreement level +- 0.0 % 0.0 %
L4-04 Speed agreement width +- 4.0 % 4.0 %
L4-05 Reference loss selection 0 Stop 0
L4-06 Frequency reference at floss 80.0 % 80.0 %

DriveWizard iQrise for Windows (C) by Yaskawa America, Inc. 6/10

PDF created with pdfFactory Pro trial version www.pdffactory.com


Default
Parameter Value Information Setting
L4-07 Frequency Detect Selection 0 No Detection during BB 0
L4-13 Door Zone Level 0.0 % 0.0 %
L5 Fault Reset
L5-01 Number of auto restart attempts 0 0
L5-02 Auto restart operation selection 0 Not output(Fault contact is not activated) 0
L5-06 Under Voltage Fault Restart Selection 0 Same as L5-01 condition 0
L6 Overtorque Detection
L6-01 Torque detection selection 1 0 Overtorque/undertorque detection disabled 0
L6-02 Torque detection level 1 150 % 150 %
L6-03 Torque detection time 1 0.1 sec 0.1 sec
L6-04 Torque detection selection 2 0 Overtorque/undertorque detection disabled 0
L6-05 Torque detection level 2 150 % 150 %
L6-06 Torque detection time 2 0.1 sec 0.1 sec
L7 Torque Limit
L7-01 Forward drive torque Limit 200 % 200 %
L7-02 Reverse drive torque Limit 200 % 200 %
L7-03 Forward regenerative torque limit 200 % 200 %
L7-04 Reverse regenerative torque limit 200 % 200 %
L7-16 Torque Limit rise mode selection at start 1 Effective delay time 1
L8 Hardware Protection
L8-02 Overheat pre-alarm level 120 °C 120 °C
L8-03 Overheat pre-alarm selection 3 Operation continued(monitor display only) 3
L8-05 Phase loss input selection 1 Enabled always 1
*L8-06 Phase loss input... [M] 18.0 % 22.0 %
L8-07 Phase loss output selection 0 Disabled 0
L8-09 Ground protection selection 1 Enable 1
L8-10 Cooling fan control selection 0 Operates when inverter is running 0
L8-11 Cooling fan control delay time 60 sec 60 sec
L8-12 Ambient temperature 40 °C 40 °C
L8-15 OL characteristics at low speeds 1 L8-16,17 setting enable 1
L8-27 Overcurrent detection level 300.0 % 300.0 %
*L8-29 Current imbalanced protection(LF... [M] 0 Disable 1
L8-38 Torque Boost Function Selection 0 Disabled 0
L8-39 Reduction carrier frequency 3.0 kHz 3.0 kHz
L8-55 Internal DB Transistor Protection 1 Enable 1
Enable/Disable Selection
L8-62 Operation selection at Input phase loss 1 Coast to Stop 1
L8-77 Oscill Suppress 0 0
L8-88 Safety Operation Mode 1 Mode 1 (L7 mode) 1
L8-89 Current monitor function selection 0 Disabled 0
L8-99 Current monitor level 10.0 % 10.0 %
n1 Hunting Prevention
n1-08 leacage current vibration control selection 0 method 1 0
n5 Feed Forward Control
n5-01 Feed forward control selection 0 Disable 0
*n5-02 Motor acceleration time... [M] 0.355 sec 0.100 sec
n5-03 Feed forward proportional gain 1.00 1.00
n5-07 Speed Feedback Compensation Selection 0 Speed Feedback Compensation Disable 0

DriveWizard iQrise for Windows (C) by Yaskawa America, Inc. 7/10

PDF created with pdfFactory Pro trial version www.pdffactory.com


Default
Parameter Value Information Setting
n5-08 Speed Feedback Compensation P Gain 3.00 3.00
n8 Permanent Magnet Motor Control
n8-01 Initial Polarity Estimation Current 50 % 50 %
n8-02 Polar Attraction Current 80 % 80 %
n8-29 q-Axis Current Control Gain during Normal 1000 rad/s 1000 rad/s
Operation
n8-30 q-Axis Current Control Integral Time during 10.0 ms 10.0 ms
Normal Operation
n8-32 d-Axis Current Control Gain during Normal 1000 rad/s 1000 rad/s
Operation
n8-33 d-Axis Current Control Integral Time during 10.0 ms 10.0 ms
Normal Operation
*n8-35 Initial Magnetic Pole Detection ... [M] 2 Pulse Method 1
*n8-36 High Frequency Overlap Frequency... [M] 423 Hz 500 Hz
*n8-37 High Frequency Amplitude Level... [M] 80.0 % 20.0 %
n8-62 Output voltage limit 400.0 VAC 400.0 VAC
n8-81 Superimposed Harmonic Frequency during 90 Hz 90 Hz
Rescue operation
*n8-82 Superimposed Harmonic Amplitude ... [M] 8.5 % 15.0 %
n8-84 Polarity detection current 100 % 100 %
n8-86 Magnet Pole Search Error Detection Selection 0 Disabled 0
n9 Factory Level
n9-60 A / D conversion start delay time 14.0 us 14.0 us
o1 Display Settings
o1-01 Monitor selection 106 Output voltage 106
o1-02 Monitor selection after power up 1 Frequency reference 1
o1-03 Display scaling 1 0.01% units 1
o1-04 Unit Selection of Frequency of V/F pattern 1 r/min units 1
setting
o1-05 LCD Contrast Control 3 3
o1-06 Monitor Mode Selection 0 Scroll 0
o1-07 2 dig Mon Sel 102 Output Frequency 102
o1-08 3 dig Mon Sel 103 Output Current 103
o1-12 Length Unit Selection 0 metric unit 0
o1-20 Traction sheave diameter 400 mm 400 mm
o1-21 Roping Ratio 2 1:2 2
o1-22 Mechanical gear ratio 1.00 1.00
o1-23 HBB nondisplay sel 0 disable 0
o2 Key Selections
o2-01 LOCAL/REMOTE key enable/disable 0 Disable 0
o2-02 Operation STOP key 0 Enabled when the inverter is operated by dig. Operator 0
o2-04 KVA selection 9D CIMR-L*4*0031*** 9D
o2-05 Frequency Reference Setting Method 0 Enter key needed 0
Selection
o2-06 Operator detection 0 Operation continues even if the dig. Operator is disconnected 0
o2-09 Initialize mode selection 3 Chinese spec 3
o3 Copy Function
*o3-02 Copy Allowed Selection... [M] 1 Enabled - Copying allowed. 0
o4 Maintenance Period
o4-02 Cumulative operation time selection 0 Cumulative time when the Inverter power is on 0
o4-03 Fan operation time setting 197 1=10H 197 1=10H
o4-05 Capacitor maintenance setting 0% 0%
o4-07 Rush-in prevention relay maintenance setting 0 % 0%
o4-09 IGBT maintenance setting 0% 0%

DriveWizard iQrise for Windows (C) by Yaskawa America, Inc. 8/10

PDF created with pdfFactory Pro trial version www.pdffactory.com


Default
Parameter Value Information Setting
o4-16 Mainenance Monitoring Selection 1000 1000
S1 Brake Sequence
S1-01 Zero Speed Level at Stop 0.350 % 0.350 %
S1-04 DC Injection / Zero Servo Time at Start 0.40 sec 0.40 sec
S1-05 DC Injection / Zero Servo Time at Stop 0.60 sec 0.60 sec
S1-06 Brake Release Delay Time 0.20 sec 0.20 sec
S1-07 Brake Close Delay Time 0.10 sec 0.10 sec
S1-10 Run Command Delay Time 0.10 sec 0.10 sec
S1-11 Output Contactor Open Delay Time 0.10 sec 0.10 sec
S1-12 Atun Contactor ON 0 Disabled 0
S1-26 Emergency stop speed level 10.0 % 10.0 %
S3 Start Stop Optimization
S3-01 Position Lock Gain at Start 1 5 5
S3-02 Position Lock Gain at Start 2 0.00 0.00
S3-03 Position Lock Gain at Stop 5 5
S3-04 Position Lock Bandwidth 10 10
S3-10 Starting Torque Compensation Increase Time 500 ms 500 ms
S3-12 Starting Torque Compensation Bias During 0.0 % 0.0 %
Lowering
S3-14 Torque Compensation Fade Out Speed 0.0 Hz 0.0 Hz
S3-15 Torque Compensation Fade Out Time 1000 ms 1000 ms
S3-16 Torque Limit Reduction TIme 100 ms 100 ms
S3-20 Dwell2 Speed Reference 0.00 % 0.00 %
S3-21 Dwell2 End Speed 0.00 % 0.00 %
*S3-27 Torque compensation value with l... [M] -98.5 % -50.0 %
*S3-28 Torque compensation value with l... [M] 68.5 % 50.0 %
S3-29 Analog input from load cell with load condition 0.0 % 0.0 %
1
S3-30 Analog input from load cell with load condition 100.0 % 100.0 %
2
S3-34 ARB torque bias 1 0.0 % 0.0 %
S3-35 ARB torque bias 2 0.0 % 0.0 %
S3-37 Position deviation level to apply torque bias 1 0 0
S3-38 Position deviation level to apply torque bias 2 0 0
S3-39 ARB Integral gain 0.00 0.00
S3-40 Movement Detection Level 1 1
S3-41 ARB Gain 2 Reduction 0.50 0.50
S4 Rescue Operation
S4-01 Light Load Direction Search Selection 0 Disabled 0
S4-03 Light Load Direction Search Time 1.0 sec 1.0 sec
S4-04 Light Load Direction Search Speed Reference 10.00 % 10.00 %
S4-05 Rescue Operation Torque Limit 100 % 100 %
S4-06 Rescue Operation Power Supply Selection 0 Battery 0
S4-07 UPS Power 0.0 kVA 0.0 kVA
S4-08 UPS Operation Speed Limit Selection 2 Enabled 2
S4-12 Main Circuit Voltage During Rescue Operation 0 V 0V
S4-13 Rescue Operation Power Supply Deterioration 80 % 80 %
Detection Level
S4-15 Fref sel on rescue operation 0 D1-25 0
S5 Short Floor Operation
S5-01 Short Floor Operation Selection 0 Disabled 0

DriveWizard iQrise for Windows (C) by Yaskawa America, Inc. 9/10

PDF created with pdfFactory Pro trial version www.pdffactory.com


Default
Parameter Value Information Setting
S5-02 Normal Speed for Short Floor Calculation 0.0 % 0.0 %
S5-03 Short Floor Minimum Constant Speed Time 0.0 sec 0.0 sec
S5-04 Distance Calculation Acceleration Time Gain 150.0 % 150.0 %
S5-05 Distance Calculation Deceleration Time Gain 150.0 % 150.0 %
S5-10 Stopping Method Selection 0 Speed Control 0
S5-11 Deceleration Distance 0 mm 0 mm
S5-12 Stop Distance 0 mm 0 mm
S5-13 Direct Landing Minimum Speed Level 20.0 % 20.0 %
S6 Error Detection
S6-01 SE1 Detection/Reset Seletion 0 Manual Reset 0
S6-05 SE4 Detection Time 500 ms 500 ms
*S6-10 Overaccleeration Detection Level... [M] 5.5 m/s^2 1.5 m/s^2
S6-11 Overaccleeration Detection Time 50 ms 50 ms
S6-12 Overacceleration Detection Selection 0 During Power On 0
S6-15 Speed Reference Loss Detection 1 Enabled 1
S6-16 Restart after Baseblock Selection 0 Restart Disabled. The Run command has to be cycled to 0
restart

DriveWizard iQrise for Windows (C) by Yaskawa America, Inc. 10/10