CONSTRUCTION OF 6-LANE ACCESS-CONTROLLED GREENFIELD HIGHWAY FROM

KM 88.000 TO KM 115.000 OF SANGARIYA-RASISAR SECTION OF NH-754K AS A PART


OF AMRITSAR-JAMNAGAR ECONOMIC CORRIDOR(EC) IN HARYANA AND
RAJASTHAN ON EPC UNDER BHARATMALA PARIYOJANA (PHASE-I) (AJ/SR-
PACKAGE-4)

Client :-
National Highways Authority of India
(Ministry of Road Transport & Highways)

Authority Engineer:-
LEA Associates South Asia Pvt. Ltd.
LEA Associates South Asia
Pvt. Ltd.
B-1, E-27, Mohan Cooperative
Industrial Estate Mathura Road
New Delhi-110044, India
B-1, E-27, Mohan Cooperative Industrial Estate Mathura Road
Email : lasa@lasaindia.com

New Delhi-110044, India Email : lasa@lasaindia.com

Proof Consultant:-
Infrastructure Development Consultants
141, Sahayog Vihar, Apex Bank Colony,
E- 8 Extension, Near Gulmohar Colony,
Bhopal (M.P) – 462039,
Phone:0755-4252393
E-mail: idc@idc-india.com, idcbpl@gmail.com

Contractor :- M/s Krishna Constructions


H.No.-95, Golden Avenue Third
Roorkee Road, Meerut (u.p.)

Design Consultant :- Nitya Nayra Civil Solution Pvt. Ltd. Bhopal


H.N.-104,Indus Empire Phase-II, E-8,
Bawadiya Kala Bhopal (M.P.)
Phone:0755-4944349

Design of PSC Girder at Schedule ch.- 109+720


Design of PSC Girder at Design ch.- 109+720

Date Revision Description Designed Checked Approved


Apr-2020 R0 Submission For Review

Design Director : Mr. Ashok Singh

Nitya Nayra Civil Solution H.N.-104,Indus Empire Phase-II, E-8, Bawadiya Kala Bhopal
Phone:0755-4944349
Pvt. Ltd. Bhopal (M.P.) Phone:0755-4944349
Design ch-109+720
Design of PSC Girder

INDEX

Sr. No. Content

1 Design Inputs for PSC Girder

2 Section Properties

3 Load Calculations

4 Prestress Cable Details

5 Calculation of Prestress Losses for all Cables

6 Summary of Forces & Bending Moments for Outer Girder

7 Summary of Forces & Bending Moments for Inner Girder

8 Check for Outer Girder Stresses with Superior Load Combination gsup=1.1

9 Check for Outer Girder Stresses with Inferior Load Combination ginf=0.9

10 Check for Inner Girder Stresses with Superior Load Combination gsup=1.1

11 Check for Inner Girder Stresses with Inferior Load Combination ginf=0.9

12 Check for Shear Capacity

13 Check for Ultimate Bending Moment Capacity

14 Stress Calculation Due to Temperature Outer Girder

15 Stresses due to Differential Shrinkage

16 Design of Anchorage Zone

17 Design of End/Intermediate Diaphgram

18 Staad Input for PSC Girder

19 Creep Coefficient/Shrinkage Calculation

20 Material Properties of Reinforcing Steel & Concrete

EPC Contractor-M/s Krishna Constructions 2


Design ch-109+720
Design of PSC Girder

SALIENT FEATURES OF THE BRIDGE DECK :

Span c/c of Exp. Joint = 35 m Sk. 32.8892 m Sq.


Exp. Gap = 50 mm.
Overall span = 34.95 m Sk. 32.8423 m Sq.
c/L of brg. c/L of exp. Joint = 0.8 m Sk. 0.75175 m Sq.
Span c/c of brg. = 33.4 m Sk. 31.3857 m Sq.
Overhang beyond c/L brg. = 0.775 m Sk. 0.72826 m Sq.
Thickness of End Cross-Girder = 0.426 m Sk. 0.4 m Sq.
Thickness of Intermediate Cross-Girder = 0.319 m Sk. 0.3 m Sq.
Girder overhang beyond c/l brg = 0.55 m Sk. 0.51683 m Sq.
Overall Length of Girder = 34.5 m Sk. 32.4194 m Sq.
Skew Angle = 20 degree

Overall carriageway width = 15.431 mm Sk. 14.5 mm Sq.


Wearing Coat Thickness = 65 mm

Depth of Precast Beam = 2.3 m


Thickness of Cast-in-situ deck = 0.22 m
Overall depth Beam + Deck Slab = 2.52 m
c/c of girder (Transverse direction) = 3 mm Sq. 3.19253 mm Sk.
Nos. of Girder = 5 Nos.
Deck Cantilever in Transverse Direction = 1.25 m

Density of Concrete = 2.5 t/m3


Density of Green Concrete = 2.6 t/m3
Size of bearing = 0.9 x 0.9 m
(Long.) (Trans.)

PROPORTIONING OF PRECAST BEAM


1 1

0.175 0.175
ht1 0.075 0.0181
0.3625 0.0875

0.275 1.675 2.3 2.1069 2.3

0.275
0.175
0.2

bw2 = 0.825 0.825

Section at Mid Span Section at Support

Web Thickening
0.426

0.562 c/L

0.825 0.275

0.55

0.775 0.4 3.5 12.8


16.7
web thickness variation along span

c/L P. brg

EPC Contractor-M/s Krishna Constructions 3


Design ch-109+720
Design of PSC Girder

Web Thickening 0.95 3.5 4.45 8.35


Section At Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L Permanent brg. (m) -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
Dist. From face of girder (m) 0 0.15 0.55 0.763 0.95 2.692 4.45 4.725 8.9 13.075 17.25
Dist. From jacking point (m) -0.15 0 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Dist. From c/L temp. brg. (m) 0 0.15 0.55 0.763 0.95 2.692 4.45 4.725 8.9 13.075 17.25

bw m 0.825 0.825 0.825 0.825 0.825 0.55126 0.275 0.275 0.275 0.275 0.275

Overall depth of composite girder = 2.52 m


deff = 2.142 */ Assumed 0.85 times of overall depth

MATERIAL USED :
Grade of Reinforcement = 500
fyk = 500 Mpa
Modulus of Elasticity Es = 200000 Mpa

Cast insitu deck = 40


fck = 40 Mpa
fcm = 50 MPa
Ecm = 33000 MPa

Precast Beam = 50
fck = 50
fcm = 60 MPa
Ecm = 35000 MPa

fctk,0.05 = Characteristic axial tensile strength of concrete


= 2.5 MPa

ANALYSES ASSUMPTION
Enviromental parameters
Relative humidity = 57.5 %
Exposure condition = Moderate

TEMPERATURE
Coefficent of thermal expansion = 0.000012 /oC

FOR PRECAST BEAM


Modulus of Elasticity
For short Term loading Ecm = 35000 Mpa
For long Term loading Ecm' = Ecm/ (1+f)
f = Creep coefficent

Creep
Cross-sectional Area Ac = 1.517485 m2
Perimeter in contact with atmosphere u = 8.920899 m (Composite Outer Girder at Mid Span Considered)
Notational size ho 2Ac/u = 340.2089 mm
f (¥) = 1.40441 (Refer Appendix B)
@ 1.544851 *(Increased by 10% on the conservative side)
Ecm' = 13753.26 N/mm2

EPC Contractor-M/s Krishna Constructions 4


Design ch-109+720
Design of PSC Girder

SERVICEABILITY LIMIT STATE :

Rare Combination
Max permissible Stress in Concrete = 0.48*fck = 24 Mpa
Max permissible tensile Stress in Concrete fctm = -3.5156 Mpa (fctm ( mean tensile strength))

Quasi permanent Combination


Max permissible Stress in Concrete = 0.36*fck = 18 Mpa
Max permissible Stress in Steel = 0.8*fyk = 400 Mpa
Permissible crack width wk,max = 0.3 mm

c/L Brg.
CRASH BARRIER 0.5

14.5

13.5

CRASH BARRIER 0.5

33.4
34.95
PLAN

14.5

0.22

c/L Jack Nos. of Girder = 5 2.3 2.52

0.9
1.25 Sq 3 Sq
1.33022 Sk 3.192533 Sk
Super-structure Cross-section

EPC Contractor-M/s Krishna Constructions 5


Design ch-109+720
Design of PSC Girder

PROPERTY CALCULATION OF PRECAST BEAM :-


Density of concrete = 2.5 t/m3

A) INNER/ OUTER GIRDER :

1 1

1 0.175 1 0.175
2 0.075 2 0.0181
3

0.275 2.3 2.3


3

4 0.175
5 0.2

0.825 0.825

Section at Mid Span Section at Support

Section Property At Mid Span


B D A cgy' IZZ cgz' Iyy
Element No.Factor m m Nos. m2 m m4 m m4
1 1 0.3625 0.175 2 0.1269 0.0875 0.1429 0.3188 0.0143
2 0.5 0.3625 0.075 2 0.0272 0.2 0.0244 0.2583 0.002
3 1 0.275 2.3 1 0.6325 1.15 0.2788 0 0.004
4 0.5 0.275 0.175 2 0.0481 2.0417 0.0385 0.275 0.0038
5 1 0.275 0.2 2 0.11 2.2 0.1222 0.2292 0.0065

Total 0.9447 1.1476 0.6069 0.0306

UDL = 0.94469 x 2.5 = 2.3617 t/m

Section Property At Support Section


B D A cgy' IZZ cgz' Iyy
Element No.Factor m m Nos. m2 m m4 m m4
1 1 0.0875 0.175 2 0.0306 0.0875 0.0335 0.4563 0.0064
2 0.5 0.0875 0.0181 2 0.0016 0.181 0.0014 0.4417 0.0003
3 1 0.825 2.3 1 1.8975 1.15 0.8371 0 0.1076

Total 1.9297 1.1323 0.872 0.1143

UDL = 1.92971 x 2.5 = 4.8243 t/m

Section At unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
web width bw m 0.825 0.825 0.825 0.825 0.825 0.5513 0.275 0.275 0.275 0.275 0.275
Area A m2 1.9297 1.9297 1.9297 1.9297 1.9297 1.4394 0.9447 0.9447 0.9447 0.9447 0.9447
IZZ m4 0.872 0.872 0.872 0.872 0.872 0.7401 0.6069 0.6069 0.6069 0.6069 0.6069
Iyy m4 0.1143 0.1143 0.1143 0.1143 0.1143 0.0727 0.0306 0.0306 0.0306 0.0306 0.0306
yb m 1.1677 1.1677 1.1677 1.1677 1.1677 1.16 1.1524 1.1524 1.1524 1.1524 1.1524
yt m 1.1323 1.1323 1.1323 1.1323 1.1323 1.14 1.1476 1.1476 1.1476 1.1476 1.1476

EPC Contractor-M/s Krishna Constructions 6


Design ch-109+720
Design of PSC Girder

EFFECTIVE WIDTH CALCULATION :

Effective Span lo = Min Distance from bearing to bearing


Clear distance b/w supports + Effetive depth

Bearing Size in Longitudinal dir.n = 0.9 m

lo = Min 33.4
32.5 + 2.142
*/ (Effective depth assumed 0.85 times of Overall depth)
lo = 33.4 m

bef
bef1 bef2

1.1125 bw = 0.275 2.52


b1,2= 1.3625

2.75 b= 3

1.25 3

beff. CALCULATION FOR INNER GIRDER :


b1,2 = 1.3625

beff1,2 = Min 0.2 bi + 0.1 lo = 3.6125 m


0.2 lo = 6.68 m

beff1,2 = 3.6125 m

beff = Min å beff,i + bw = 7.5 m


b = 3m

beff = 3m

beff. CALCULATION FOR OUTER GIRDER :


b1 = 1.1125 m b2 = 1.3625 m

beff1 = Min 0.2 bi + 0.1 lo = 3.5625 m


0.2 lo = 6.68 m

beff1 = 3.5625 m

beff2 = Min 0.2 bi + 0.1 lo = 3.6125 m


0.2 lo = 6.68 m

beff2 = 3.6125 m

beff = Min å beff,i + bw = 7.45 m


b = 2.75 m

beff = 2.75 m

EPC Contractor-M/s Krishna Constructions 7


Design ch-109+720
Design of PSC Girder

PROPERTY CALCULATION OF COMPOSITE BEAM :


fcm = Mean value of concrete compressive strength
fcm = fck + 10 */ fcm & fck are in Mpa

Ecm = Secant modulus of elasticity


Ecm = 22 * ( fcm /12.5 )0.3

Material fcm Ecm


Concrete Grade (fck)
MPa
Mpa MPa
Deck slab = 40 50 33345.8
Pre-cast section = 50 60 35220.5

Modular ratio (EcmP / EcmD) = 1.05622

A) OUTER GIRDER :
(Equivalent to Precast Beam grade) (Equivalent to Precast Beam grade)
2.75 @ 2.60362 2.75 @ 2.60362

1 1 0.22 1 1 0.22

2 0.175 2 0.175
3 0.075 3 0.0181
4
2.52 2.52
0.275 2.3 2.3
4

5 0.175
6 0.2

0.825 0.825

Section at Mid Span Section at Support

Section Property At Mid Span


B D A cgy' IZZ cgz' Iyy Perimeter (with atmosphere (m) )
Element No.
Factor m m Nos. m2 m m4 m m4 CompositePrecast Deck
1 1 2.60362 0.22 1 0.5728 0.11 0.35342 0 0.32358 2.60362 2.60362
2 1 0.3625 0.175 2 0.12688 0.3075 0.04381 0.31875 0.01428 0.35 0.35
3 0.5 0.3625 0.075 2 0.02719 0.42 0.00609 0.25833 0.00201 0.74035 0.74035
4 1 0.275 2.3 1 0.6325 1.37 0.42278 0 0.00399 3.35 3.35
5 0.5 0.275 0.175 2 0.04813 2.26167 0.09024 0.275 0.00384 0.65192 0.65192
6 1 0.275 0.2 2 0.11 2.42 0.25688 0.22917 0.00647 1.225 1.225

Total 1.51748 0.89293 1.17322 0.35417 8.9209 6.31727 2.60362

Section Property At Support Section


B D A cgy' IZZ cgz' Iyy
Element No.Factor m m Nos. m2 m m4 m m4
1 1 2.60362 0.22 1 0.5728 0.11 0.52798 0 0.32358
2 1 0.0875 0.175 2 0.03063 0.3075 0.01779 0.45625 0.00639
3 0.5 0.0875 0.0181 2 0.00158 0.40103 0.0007 0.44167 0.00031
4 1 0.825 2.3 1 1.8975 1.37 1.00956 0 0.10762

Total 2.50251 1.06798 1.55604 0.4379

EPC Contractor-M/s Krishna Constructions 8


Design ch-109+720
Design of PSC Girder

Composite cross-section properties outer girder


Section At unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
web width bw m 0.825 0.825 0.825 0.825 0.825 0.55126 0.275 0.275 0.275 0.275 0.275
Area A m2 2.50251 2.50251 2.50251 2.50251 2.50251 2.01225 1.51748 1.51748 1.51748 1.51748 1.517
IZZ m4 1.55604 1.55604 1.55604 1.55604 1.55604 1.36551 1.17322 1.17322 1.17322 1.17322 1.173
Iyy m4 0.4379 0.4379 0.4379 0.4379 0.4379 0.39623 0.35417 0.35417 0.35417 0.35417 0.354
yb m 1.45202 1.45202 1.45202 1.45202 1.45202 1.53914 1.62707 1.62707 1.62707 1.62707 1.627
yt m 1.06798 1.06798 1.06798 1.06798 1.06798 0.98086 0.89293 0.89293 0.89293 0.89293 0.893
Gtop m 0.84798 0.84798 0.84798 0.84798 0.84798 0.76086 0.67293 0.67293 0.67293 0.67293 0.673

B) INNER GIRDER :
(Equavelent to Precast Beam grade) (Equavelent to Precast Beam grade)
3@ 2.84032 3@ 2.84032

1 1 0.22 1 1 0.22

2 0.175 2 0.175
3 0.075 3 0.0181
4
2.52 2.52
0.275 2.3 2.3
4

5 0.175
6 0.2

0.825 0.825

Section at Mid Span Section at Support

Section Property At Mid Span


B D A cgy' IZZ cgz' Iyy
Element No.Factor m m Nos. m2 m m4 m m4
1 1 2.84032 0.22 1 0.62487 0.11 0.36056 0 0.42009
2 1 0.3625 0.175 2 0.12688 0.3075 0.04003 0.31875 0.01428
3 0.5 0.3625 0.075 2 0.02719 0.42 0.00544 0.25833 0.00201
4 1 0.275 2.3 1 0.6325 1.37 0.43888 0 0.00399
5 0.5 0.275 0.175 2 0.04813 2.26167 0.0937 0.275 0.00384
6 1 0.275 0.2 2 0.11 2.42 0.26568 0.22917 0.00647

Total 1.56956 0.86696 1.20429 0.45068

Section Property At Support Section


B D A cgy' IZZ cgz' Iyy
Element No.Factor m m Nos. m2 m m4 m m4
1 1 2.84032 0.22 1 0.62487 0.11 0.55284 0 0.42009
2 1 0.0875 0.175 2 0.03063 0.3075 0.01689 0.45625 0.00639
3 0.5 0.0875 0.0181 2 0.00158 0.40103 0.00066 0.44167 0.00031
4 1 0.825 2.3 1 1.8975 1.37 1.03267 0 0.10762

Total 2.55458 1.04846 1.60306 0.53442

EPC Contractor-M/s Krishna Constructions 9


Design ch-109+720
Design of PSC Girder

Composite cross-section properties inner girder


Section At unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
web width bw m 0.825 0.825 0.825 0.825 0.825 0.55126 0.275 0.275 0.275 0.275 0.275
Area A m2 2.55458 2.55458 2.55458 2.55458 2.55458 2.06432 1.56956 1.56956 1.56956 1.56956 1.57
IZZ m4 1.60306 1.60306 1.60306 1.60306 1.60306 1.40459 1.20429 1.20429 1.20429 1.20429 1.204
Iyy m4 0.53442 0.53442 0.53442 0.53442 0.53442 0.49274 0.45068 0.45068 0.45068 0.45068 0.451
yb m 1.47154 1.47154 1.47154 1.47154 1.47154 1.56188 1.65304 1.65304 1.65304 1.65304 1.653
yt m 1.04846 1.04846 1.04846 1.04846 1.04846 0.95812 0.86696 0.86696 0.86696 0.86696 0.867
Gtop m 0.82846 0.82846 0.82846 0.82846 0.82846 0.73812 0.64696 0.64696 0.64696 0.64696 0.647

PROPERTY OF END CROSS GIRDER :


0.9738 beff. CALCULATION FOR END CROSS GIRDER :
lo = 1.764
1 0.22 b1 = 0.775 m , b2 = 0.2 m
beff1 = Min 0.2 bi + 0.1 lo = 0.3314 m
2.32 0.2 lo = 0.3528 m
beff1 = 0.3314 m
2 2.1 beff2 = Min 0.2 bi + 0.1 lo = 0.2164 m
0.2 lo = 0.3528 m
beff2 = 0.2164 m
beff = Min å beff,i + bw = 0.9738 m
0.426 b = 0.975 m
beff = 0.9738 m
Section Property
B D A cgy' IZZ cgz' Iyy
Element No.
Factor m m Nos. m2 m m4 m m4
1 1 0.9738 0.22 1 0.21424 0.11 0.18851 0 0.01693
2 1 0.426 2.1 1 0.8946 1.27 0.3737 0 0.01353

Total 1.10884 1.04588 0.56221 0.03046

PROPERTY OF INTERMEDIATE CROSS GIRDER :


1.0246 beff. CALCULATION FOR INTERMEDIATE CROSS GIRDER :
lo = 1.764
1 0.22 b1 = 2.0875 m , b2 = 2.0875 m
beff1 = Min 0.2 bi + 0.1 lo = 0.5939 m
2.32 0.2 lo = 0.3528 m
beff1 = 0.3528 m
2 2.1 beff2 = Min 0.2 bi + 0.1 lo = 0.5939 m
0.2 lo = 0.3528 m
beff2 = 0.3528 m
beff = Min å beff,i + bw = 1.0246 m
0.319 b = 4.175 m
beff = 1.0246 m
Section Property
B D A cgy' IZZ cgz' Iyy
Element No.
Factor m m Nos. m2 m m4 m m4
1 1 1.0246 0.22 1 0.22541 0.11 0.17072 0 0.01972
2 1 0.319 2.1 1 0.6699 1.27 0.30333 0 0.00568

Total 0.89531 0.97795 0.47405 0.0254

EPC Contractor-M/s Krishna Constructions 10


Design ch-109+720
Design of PSC Girder

CALCULATING IST MOMENT OF INERTIA OF PRECAST BEAM & COMPOSITE SECTION ABOVE CG. OF COMPOSITE SECTION :

fcm = Mean value of concrete compressive strength


fcm = fck + 10 */ fcm & fck are in Mpa

Ecm = Secant modulus of elasticity


Ecm = 22 * ( fcm /12.5 )0.3

Material fcm Ecm


Concrete Grade (fck)
MPa
Mpa MPa
Deck slab = 40 50 33345.8
Pre-cast section = 50 60 35220.5

Modular ratio (EcmP / EcmD) = 1.05622

A) OUTER GIRDER :
(Equivalent to Precast Beam grade) (Equivalent to Precast Beam grade)
2.75 @ 2.60362 2.75 @ 2.60362

1 1 0.22 1 1 0.22

2 0.175 2 0.175
3 0.075 3 0.0181
4
2.52 2.52
0.275 2.3 2.3
4

5 0.175
6 0.2

0.825 0.825

Section at Mid Span Section at Support

*/ First moment of inertia of composite section above cg. of composite section


*/At Mid span
Cg from top of deck = 0.89293 m
B D A cgy' cgy'cg A*cgy'cg
Element No. Factor m m Nos. m2 m m m3
1 1 2.60362 0.22 1 0.5728 0.11 0.78293 0.44846
2 1 0.3625 0.175 2 0.12688 0.3075 0.58543 0.07428
3 0.5 0.3625 0.075 2 0.02719 0.42 0.47293 0.01286
4 1 0.275 0.67293 1 0.18506 0.55647 0.33647 0.06226

Total 0.91192 0.59786

*/Section at support
Cg from top of deck = 1.06798 m
B D A cgy' cgy'cg A*cgy'cg
Element No.
Factor m m Nos. m2 m m m3
1 1 2.60362 0.22 1 0.5728 0.11 0.95798 0.54873
2 1 0.0875 0.175 2 0.03063 0.3075 0.76048 0.02329
3 0.5 0.0875 0.0181 2 0.00158 0.40103 0.66695 0.00106
4 1 0.825 0.84798 1 0.69959 0.64399 0.42399 0.29662

Total 1.30459 0.8697

EPC Contractor-M/s Krishna Constructions 11


Design ch-109+720
Design of PSC Girder

*/ First moment of inertia of precast section above cg. of composite section


*/At Mid span
Cg from top of deck = 0.89293 m
B D A cgy' cgy'cg A*cgy'cg
Element No. Factor m m Nos. m2 m m m3
2 1 0.3625 0.175 2 0.12688 0.0875 0.80543 0.10219
3 0.5 0.3625 0.075 2 0.02719 0.2 0.69293 0.01884
4 1 0.275 0.67293 1 0.18506 0.33647 0.55647 0.10298

Total 0.33912 0.22401

*/Section at support
Cg from top of deck = 1.06798 m
B D A cgy' cgy'cg A*cgy'cg
Element No.
Factor m m Nos. m2 m m m3
2 1 0.0875 0.175 2 0.03063 0.0875 0.98048 0.03003
3 0.5 0.0875 0.0181 2 0.00158 0.18103 0.88695 0.0014
4 1 0.825 0.84798 1 0.69959 0.42399 0.64399 0.45053

Total 0.7318 0.48196

Ist moment of inertia of composite & precast section


Section At unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
Composite section
Ayc m3 0.8697 0.8697 0.8697 0.8697 0.8697 0.7344 0.59786 0.59786 0.59786 0.59786 0.5979
Precast section
Ayp m3 0.48196 0.48196 0.48196 0.48196 0.48196 0.35357 0.22401 0.22401 0.22401 0.22401 0.224

EPC Contractor-M/s Krishna Constructions 12


Design ch-109+720
Design of PSC Girder

B) INNER GIRDER :
(Equavelent to Precast Beam grade) (Equavelent to Precast Beam grade)
3@ 2.84032 3@ 2.84032

1 1 0.22 1 1 0.22

2 0.175 2 0.175
3 0.075 3 0.0181
4
2.52 2.52
0.275 2.3 2.3
4

5 0.175
6 0.2

0.825 0.825

Section at Mid Span Section at Support

*/ First moment of inertia of composite section above cg. of composite section


*/At Mid span
Cg from top of deck = 0.86696 m
B D A cgy' cgy'cg A*cgy'cg
Element No. Factor m m Nos. m2 m m m3
1 1 2.84032 0.22 1 0.62487 0.11 0.75696 0.473
2 1 0.3625 0.175 2 0.12688 0.3075 0.55946 0.07098
3 0.5 0.3625 0.075 2 0.02719 0.42 0.44696 0.01215
4 1 0.275 0.64696 1 0.17791 0.54348 0.32348 0.05755

Total 0.95685 0.61368

*/Section at support
Cg from top of deck = 1.04846 m
B D A cgy' cgy'cg A*cgy'cg
Element No.
Factor m m Nos. m2 m m m3
1 1 2.84032 0.22 1 0.62487 0.11 0.93846 0.58641
2 1 0.0875 0.175 2 0.03063 0.3075 0.74096 0.02269
3 0.5 0.0875 0.0181 2 0.00158 0.40103 0.64742 0.00103
4 1 0.825 0.82846 1 0.68348 0.63423 0.41423 0.28311

Total 1.34055 0.89324

*/ First moment of inertia of precast section above cg. of composite section


*/At Mid span
Cg from top of deck = 0.86696 m
B D A cgy' cgy'cg A*cgy'cg
Element No. Factor m m Nos. m2 m m m3
2 1 0.3625 0.175 2 0.12688 0.0875 0.77946 0.09889
3 0.5 0.3625 0.075 2 0.02719 0.2 0.66696 0.01813
4 1 0.275 0.64696 1 0.17791 0.32348 0.54348 0.09669

Total 0.33198 0.21372

EPC Contractor-M/s Krishna Constructions 13


Design ch-109+720
Design of PSC Girder

*/Section at support
Cg from top of deck = 1.04846 m
B D A cgy' cgy'cg A*cgy'cg
Element No.
Factor m m Nos. m2 m m m3
2 1 0.0875 0.175 2 0.03063 0.0875 0.96096 0.02943
3 0.5 0.0875 0.0181 2 0.00158 0.18103 0.86742 0.00137
4 1 0.825 0.82846 1 0.68348 0.41423 0.63423 0.43348

Total 0.71569 0.46428

Ist moment of inertia of composite & precast section


Section At unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
Composite section
Ayc m3 0.89324 0.89324 0.89324 0.89324 0.89324 0.7541 0.61368 0.61368 0.61368 0.61368 0.6137
Precast section
Ayp m3 0.46428 0.46428 0.46428 0.46428 0.46428 0.33957 0.21372 0.21372 0.21372 0.21372 0.2137

EPC Contractor-M/s Krishna Constructions 14


Design ch-109+720
Design of PSC Girder

FORCES DUE TO SELF WEIGHT GIRDER & CAST-IN-SITU DECK :

Total Depth (including deck) = 2.52 m


Density of Concrete = 2.5 t/m3
Density of Green Concrete = 2.6 t/m3

Precast Beam
4.82427 t/m
2.36172 t/m
c/L

0.55 0.4 3.5 12.8


16.7
c/L Brg. 17.25

Span -0.55 0.4 3.5 12.8


UDL 4.82427 2.36172

Bending Moment & Shear Force at Critical Sections


Precast Beam Dead Load
Support Reaction = 47.3885 T
Section At Unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
-0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
Bending Moment Tm -0 -0.0543 -0.7297 8.68949 16.7785 84.6457 142.077 150.301 253.216 314.966 335.549

Shear Force T -0 0.72364 2.65335 43.7076 42.8055 35.4691 30.23 29.5805 19.7204 9.86018 -4E-15

DECK SLAB SELF WEIGHT


Thickness of deck slab = 0.22 m Area of Intermediate Diaphragm 0.6699 m2
Width of deck slab over Outer Girder = 2.75 m End Girder Contributory length 1.5 m
Width of deck slab over Inner Girder = 3m Intermed. Girder Contributory length 3m

UDL over Girder (Inner Girder) = 1.716 t/m Weight on Outer Girder
UDL over Girder (Outer Girder) = 1.573 t/m Intermediate Diaphragm (1 nos) 2.51213 t

1.573 t/m Outer Girder Weight on Inner Girder


1.716 t/m Inner Girder Intermediate Diaphragm (1 nos) 5.02425 t
1.573 t/m Outer Girder
1.716 t/m Inner Girder
c/L

0.775 0.4 3.5 12.8


16.7
Outer Girder Inner Girder
Span -0.775 0.4 3.5 12.8 Span -0.775 0.4 3.5 12.8
UDL 1.573 1.573 UDL 1.716 1.716

Bending Moment & Shear Force at critical Sections


Deck Slab & Intermediate Diaphragm Dead Load, Outer Girder
Support Reaction = 27.4882 T
Section At Unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7

Deck -0.0398 -0.1106 -0.4724 5.08724 9.90941 52.1874 90.0144 95.4919 164.038 205.165 218.875
Diaphragm 0 0.247 0.343 2.26 2.343 3.982 7.479 6.808 20.584 30.503 33.364
Bending Moment Tm -0.0398 0.1364 -0.1294 7.34724 12.2524 56.1694 97.4934 102.3 184.622 235.668 252.239

Shear Force T 1.60999 1.84594 2.47514 27.1901 26.896 24.1558 21.3905 20.9579 14.3906 7.82334 1.25606

EPC Contractor-M/s Krishna Constructions 15


Design ch-109+720
Design of PSC Girder

Deck Slab & Intermediate Diaphragm Dead Load, Inner Girder


Support Reaction = 29.9871 T
Section At Unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7

Deck Tm -0.0434 -0.1207 -0.5153 5.54972 10.8103 56.9317 98.1976 104.173 178.95 223.817 238.772
Diaphragm Tm 0 0.042 0.042 -0.467 -0.459 4.73 8.353 6.585 19.503 29.794 29.086
Bending Moment Tm -0.0434 -0.0787 -0.4733 5.08272 10.3513 61.6617 106.551 110.758 198.453 253.611 267.858

Shear Force T 2.89823 3.15563 3.84203 30.8038 30.4829 27.4937 24.4769 24.005 16.8407 9.67643 2.51213

SUMMARY OF BENDING MOMENT DUE TO SELFWEIGT OF BEAM, DECK & DIAPHRAGM


Section At Unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7

Precast Beam Tm -0 -0.0543 -0.7297 8.68949 16.7785 84.6457 142.077 150.301 253.216 314.966 335.549

Deck slab (Outer Girder) Tm -0.0398 0.1364 -0.1294 7.34724 12.2524 56.1694 97.4934 102.3 184.622 235.668 252.239

Deck slab (Inner Girder) Tm -0.0434 -0.0787 -0.4733 5.08272 10.3513 61.6617 106.551 110.758 198.453 253.611 267.858

SUMMARY OF SHEAR FORCE DUE TO SELFWEIGT OF BEAM, DECK & DIAPHRAGM


Section At Unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7

Precast Beam T -0 0.72364 2.65335 43.7076 42.8055 35.4691 30.23 29.5805 19.7204 9.86018 -4E-15

Deck slab (Outer Girder) T 1.69049 1.93823 2.59889 28.5496 28.2408 25.3636 22.46 22.0058 15.1101 8.2145 1.31887

Deck slab (Inner Girder) T 3.04314 3.31341 4.03413 32.344 32.0071 28.8683 25.7008 25.2053 17.6828 10.1602 2.63773

EPC Contractor-M/s Krishna Constructions 16


Design ch-109+720
Design of PSC Girder

Calculation of SIDL :
Density of Concrete = 2.2 t/m3

14.5
0.5 0 13.5 0 0.5

0.065 thick WC

Overall span = 34.95 m


Crash barrier weight = 1 t/m
Cg. From crash barrier bottom = 0.476 m

Wearing coat = 0.143 t/m2

0
Footpath weight = 0 t/m
0.0001

Footpath Live load = 0.28489 t/m2


= 0 t/m

EPC Contractor-M/s Krishna Constructions 17


Design ch-109+720
Design of PSC Girder

Calculation of Wind Force

(A) WIND FORCES ON SUPERSTRUCTURE


WIND FORCE ON UNLOADED SPAN

Avg. ht of exposed surface above the Ground Level, H = 10.34 m


(C.G of superstructure to ground level)
Basic wind speed value = 47 m/s
for H = 10.34 m & Basic wind speed of 47 m/s

Design wind speed is VZ = 41.588 m/s


Wind pressure is PZ = 1.0377 kN/m2

Height of crash barrier above deck slab = 1.1 m


Height of Superstructure = 2.52 m
Total Area = 3.62 m2 per m length
Length of Superstructure (Full considered) = 35 m
width of structure = 14.5 m
Therefore,
Area of Superstr to be acted upon by wind force , A1 (Trans)
= 35 x 3.62
= 126.7 m2
Gust Factor, G = 2
b/d ratio = 5.754
Drag Coefficient, CD = 1.95 (Cl. 209.3.3 - IRC:6)

Transverse wind force FT = Pz * A1 * G * CD = 512.77 kN


Bearing to Cg of superstr = 1.653
Trans wind moment (kNm) = 847.64 kNm

Longitudinal wind force, FL = 0.25*FT = 128.19 kN

Area of Superstr to be acted upon by wind force , A1 (Vert)= 507.5 m2


Gust Factor, G = 2
Drag Coefficient, CD = 0.75

Vertical wind force FV = Pz * A3 * G * CL = 789.97 kN

Wind force for loaded span


WIND FORCE ON STRUCTURE + LL IN CASE WHERE WIND SPEED = 36 M/S

Height of the LL = 3 m
Height of crash barrier above deck slab = 1.1 m
Exposed height of the train = 1.9 m
Exposed area of the LL from left span = 66.5 m2
Design wind speed is VZ = 39.594 m/s
Wind pressure is PZ = 0.9406 kN/m2

Therefore,
Area of Live load to be acted upon by wind force , A1 (Trans)
= 66.5 m2
Area of Superstr to be acted upon by wind force , A1 (Trans)
= 126.7 m2
Gust Factor, G = 2
Drag Coefficient, CD (For live load) = 1.2 (Cl. 209.3.6 - IRC:6)
Drag Coefficient, CD (For Superstr) = 1.95

EPC Contractor-M/s Krishna Constructions 18


Design ch-109+720
Design of PSC Girder
Transverse wind force FT = Pz * A1 * G * CD = 614.9 kN
Bearing to Cg of superstr = 4.42
Trans wind moment (kNm) = 2717.9 kNm

Longitudinal wind force, FL = 0.25*FT = 153.73 kN

Area of Superstr to be acted upon by wind force , A1 (Vert)= 507.5 m2


Gust Factor, G = 2
Drag Coefficient, CD = 0.75

Vertical wind force FV = Pz * A3 * G * CL = 716.04 kN

Maximum vertical wind load = 789.97 kN


Upward and downward wind pressure = 0.1587 t/m2

EPC Contractor-M/s Krishna Constructions 19


Design ch-109+720
Design of PSC Girder

PRESTRESS-CABLE DETAILS
19-T-13/S system detail
= 1861 N/mm2
Ultimate breaking strength of one strand = 183.7 kN
Nominal dia of strand = 12.7 mm
Nominal Area of strand = 98.71 mm2
Total Nos. of strand = 19
UTS of cable = 349.03 Tonne
Area of a cable = 1875.5 mm2

Maximum Prestress Jacking Force = 90% of 0.1% of proof load


= 0.9 * 0.87 * UTS
= 0.783 * 349.03
= 273.29 Tonne

Maximum Prestressing Force Po, applied to structure immediately after transfer :


= Min 0.75 * UTS
0.85 * 0.1% proof load = 0.85 * 0.87 * UTS

= Min 0.75 * UTS


0.7395 * UTS

= 258.11 Tonne

Maximum allowable force in the cables before anchoring


(Maximum Jacking force) = 0.765 x UTS = 267.01 Tonne

STAGES : Girder Age Deck Age


Casting of concrete at day 0 -
Transfer of pre-stress at day stage-I 14 -
Transfer of pre-stress at day stage -Stage II 28 -
Casting of deck -III 35 0
Transfer over permanent Brg. - Stage IV 63 28
Placing of SIDL - Stage V 64 29
Open to LL - Stage -VI 92 57
At ∞ 36500 36465

Stressing Stages :
Stage 1
At Day 14 Strand N-1 Ap UTS
Cable No. 1 2 3 Nos. Nos mm2 T
No. of tendons 19 19 10 48 2.5263 4738.1 881.76
% Jacking 100 100 100

Stage 2
At Day 28 Strands N-1 Ap UTS
Cable No. 4 5 Nos. Nos mm2 T
No. of tendons 15 15 30 1.5789 2961.3 551.1
% Jacking 100 100

EPC Contractor-M/s Krishna Constructions 20


Design ch-109+720
Design of PSC Girder

Modulus of elasticity of cable = 195000 N/mm2


Nominal weight of cable = 14.723 kg/m
Extra length of cable required for fixing S6 Jack (from face of the guide) = 1000 mm
Extra length of cable at dead end (from face of the guide) = 200 mm

Minimum recommended internal diameter of sheathing (for threading of cable


= after concreting
90 mm
Duct ID provided = 0.09 m
Minimum clear dist b/w ducts = 0.09 m
Minimum clear cover to ducts = 0.075 m
Minimum web thk = 0.2 + duct dia
Average corrected pull - in of grips = 6 mm

At Anchorage Location
Minimum c/c of cable = 0.26 m 19 T 13 Cables
Minimum c/L of cable to concrete edge = 0.198 m
Anchor plate dimension = 0.3 x 0.300

Type of sheathing = Corrugated HDPE


wobble coefficent k = 0.002 per meter
friction coefficent m = 0.17

0.5
7
0
6
7
0 0
6 5
0 0.5 2.3
5
0.2 4
4 0.5
0.2 3
3
0.5
0
0.125 0.3

0.2125 0.2 0.2 0.2125 0.2125 0.4 0.2125


1 3 2 1 2

Section at Mid Span Section at Support

J1
c/L

Origin

0.15 0.8 3.5 12.8 O


0.8
17.25

EPC Contractor-M/s Krishna Constructions 21


Design ch-109+720
Design of PSC Girder

Cable Vertical Profile


Linear Parabolic Linear
No. Start End Start End Start End
m m m m m m
1x 0 2 2 16.1 16.1 17.1
y 0.125 0.125 0.125 0.2783 0.2783 0.3

2x 0 2 2 16.1 16.1 17.1


y 0.125 0.125 0.125 0.2783 0.2783 0.3

3x 0 2 2 16.1 16.1 17.1


y 0.125 0.125 0.125 0.7161 0.7161 0.8

4x 0 2 2 16.1 16.1 17.1


y 0.325 0.325 0.325 1.1789 1.1789 1.3

5x 0 2 2 16.1 16.1 17.1


y 0.525 0.525 0.525 1.6416 1.6416 1.8

6x 0 2 2 16.1 16.1 17.1


y 0.525 0.525 0.525 1.6416 1.6416 1.8

7x 0 2 2 16.1 16.1 17.1


y 0.525 0.525 0.525 1.6416 1.6416 1.8

Cable Horizontal Profile


Linear Parabolic Rev. Parabola Linear
No. Start End Start End Start End Start End
1x 0 1 1 3 3 5 5 17.1
z 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2

2x 0 1 1 3 3 5 5 17.1
z -0.2 -0.2 -0.2 -0.2 -0.2 -0.2 -0.2 -0.2

3x 0 1 1 2 2 3 3 17.1
z 0 0 0 0 0 0 0 0

4x 0 1 1 2 2 3 3 17.1
z 0 0 0 0 0 0 0 0

5x 0 1 1 2 2 3 3 17.1
z 0 0 0 0 0 0 0 0

6x 0 1 1 2 2 3 3 17.1
z 0 0 0 0 0 0 0 0

7x 0 1 1 2 2 3 3 17.1
z 0 0 0 0 0 0 0 0

EPC Contractor-M/s Krishna Constructions 22


Design ch-109+720
Design of PSC Girder

Geometric properties of cable profile


Vertical Profile Horizontal Profile
Cable No. : 1 Cable No. : 1
Vertical Profile Horizontal Profile
x (O) x(J1) y Curve x (O) x(J1) z Curve
17.1 0 0.3 17.1 0 0.2
16.1 1 0.2783 Linear 5 12.1 0.2 Linear
2 15.1 0.125 Parab. 3 14.1 0.2 Rev.Parab.
0 17.1 0.125 Linear 1 16.1 0.2 Parab.
0 17.1 0.2 Linear

Parabola -1 Parabola -1&2


a a2 h c s a a2 h c s
0.0008 0.0217 0.1533 14.1 14.101 0 0 0 2 2

Cable No. : 2 Cable No. : 2


Vertical Profile Horizontal Profile
x (O) x(J1) y Curve x (O) x(J1) z Curve
17.1 0 0.3 17.1 0 -0.2
16.1 1 0.2783 Linear 5 12.1 -0.2 Linear
2 15.1 0.125 Parab. 3 14.1 -0.2 Rev.Parab.
0 17.1 0.125 Linear 1 16.1 -0.2 Parab.
0 17.1 -0.2 Linear

Parabola -1 Parabola -1&2


a a2 h c s a a2 h c s
0.0008 0.0217 0.1533 14.1 14.101 0 0 0 2 2

Cable No. : 3 Cable No. : 3


Vertical Profile Horizontal Profile
x (O) x(J1) y Curve x (O) x(J1) z Curve
17.1 0 0.8 17.1 0 0
16.1 1 0.7161 Linear 3 14.1 0 Linear
2 15.1 0.125 Parab. 2 15.1 0 Rev.Parab.
0 17.1 0.125 Linear 1 16.1 0 Parab.
0 17.1 0 Linear

Parabola -1 Parabola -1&2


a a2 h c s a a2 h c s
0.003 0.0839 0.5911 14.1 14.117 0 0 0 1 1

Cable No. : 4 Cable No. : 4


Vertical Profile Horizontal Profile
x (O) x(J1) y Curve x (O) x(J1) z Curve
17.1 0 1.3 17.1 0 0
16.1 1 1.1789 Linear 3 14.1 0 Linear
2 15.1 0.325 Parab. 2 15.1 0 Rev.Parab.
0 17.1 0.325 Linear 1 16.1 0 Parab.
0 17.1 0 Linear

Parabola -1 Parabola -1&2


a a2 h c s a a2 h c s
0.0043 0.1211 0.8539 14.1 14.134 0 0 0 1 1

EPC Contractor-M/s Krishna Constructions 23


Design ch-109+720
Design of PSC Girder

Cable No. : 5 Cable No. : 5


Vertical Profile Horizontal Profile
x (O) x(J1) y Curve x (O) x(J1) z Curve
17.1 0 1.8 17.1 0 0
16.1 1 1.6416 Linear 3 14.1 0 Linear
2 15.1 0.525 Parab. 2 15.1 0 Rev.Parab.
0 17.1 0.525 Linear 1 16.1 0 Parab.
0 17.1 0 Linear

Parabola -1 Parabola -1&2


a a2 h c s a a2 h c s
0.0056 0.1584 1.1166 14.1 14.159 0 0 0 1 1

Cable No. : 6 Cable No. : 6


Vertical Profile Horizontal Profile
x (O) x(J1) y Curve x (O) x(J1) z Curve
17.1 0 1.8 17.1 0 0
16.1 1 1.6416 Linear 3 14.1 0 Linear
2 15.1 0.525 Parab. 2 15.1 0 Rev.Parab.
0 17.1 0.525 Linear 1 16.1 0 Parab.
0 17.1 0 Linear

Parabola -1 Parabola -1&2


a a2 h c s a a2 h c s
0.0056 0.1584 1.1166 14.1 14.159 0 0 0 1 1

Cable No. : 7 Cable No. : 7


Vertical Profile Horizontal Profile
x (O) x(J1) y Curve x (O) x(J1) z Curve
17.1 0 1.8 17.1 0 0
16.1 1 1.6416 Linear 3 14.1 0 Linear
2 15.1 0.525 Parab. 2 15.1 0 Rev.Parab.
0 17.1 0.525 Linear 1 16.1 0 Parab.
0 17.1 0 Linear

Parabola -1 Parabola -1&2


a a2 h c s a a2 h c s
0.0056 0.1584 1.1166 14.1 14.159 0 0 0 1 1

Forces Before Friction & Slip Loss : (Total Force)


Sections c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance jack 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Length 0.4 0.213 0.187 1.742 1.758 0.275 4.175 4.175 4.175
Cable- No.
1 267.01 267.01 267.01 267.01 267.01 267.01 267.01 267.01 267.01
2 267.01 267.01 267.01 267.01 267.01 267.01 267.01 267.01 267.01
3 140.53 140.53 140.53 140.53 140.53 140.53 140.53 140.53 140.53
4 210.79 210.79 210.79 210.79 210.79 210.79 210.79 210.79 210.79
5 210.79 210.79 210.79 210.79 210.79 210.79 210.79 210.79 210.79
6 0 0 0 0 0 0 0 0 0
7 0 0 0 0 0 0 0 0 0

EPC Contractor-M/s Krishna Constructions 24


Design ch-109+720
Design of PSC Girder

Forces Before Friction & Slip Loss : (Horizontal Component)


Sections c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Cable- No.
1 266.94 266.94 266.94 266.95 266.96 266.96 266.99 267.01 267.01
2 266.94 266.94 266.94 266.95 266.96 266.96 266.99 267.01 267.01
3 140.04 140.04 140.04 140.1 140.16 140.17 140.33 140.48 140.53
4 209.27 209.27 209.27 209.44 209.65 209.68 210.17 210.65 210.79
5 208.2 208.2 208.2 208.5 208.85 208.9 209.73 210.55 210.79
6 0 0 0 0 0 0 0 0 0
7 0 0 0 0 0 0 0 0 0

Forces before Friction & Slip Loss : (Vertical Component)


Sections c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Cable- No.
1 5.8031 5.8031 5.8031 5.1685 4.445 4.3319 2.6137 0.8954 0
2 5.8031 5.8031 5.8031 5.1685 4.445 4.3319 2.6137 0.8954 0
3 11.742 11.742 11.742 10.459 8.9949 8.7659 5.2899 1.814 0
4 25.346 25.346 25.346 22.576 19.417 18.923 11.422 3.9216 0
5 32.976 32.976 32.976 29.373 25.265 24.623 14.868 5.1131 0
6 0 0 0 0 0 0 0 0 0
7 0 0 0 0 0 0 0 0 0

Forces after Friction & Slip Loss : (Total Force)


Sections c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Cable- No.
1 244.36 244.47 244.57 245.6 246.64 246.81 249.29 251.77 254.07
2 244.36 244.47 244.57 245.6 246.64 246.81 249.29 251.77 254.07
3 127.11 127.17 127.22 127.91 128.64 128.76 130.48 132.21 133.64
4 189.35 189.44 189.52 190.7 191.95 192.14 195.11 198.07 199.58
5 188.17 188.26 188.34 189.66 191.06 191.28 194.61 197.95 198.34
6 0 0 0 0 0 0 0 0 0
7 -11.2 -11.2 -11.2 -11.2 -11.2 -11.2 -11.2 -11.2 -11.2

Forces after Friction & Slip Loss : (Horizontal Component)


Sections c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Cable- No.
1 244.3 244.41 244.51 245.55 246.6 246.77 249.27 251.77 254.07
2 244.3 244.41 244.51 245.55 246.6 246.77 249.27 251.77 254.07
3 126.66 126.72 126.78 127.52 128.31 128.43 130.3 132.17 133.64
4 187.98 188.07 188.15 189.49 190.92 191.14 194.54 197.94 199.58
5 185.86 185.94 186.02 187.61 189.32 189.59 193.66 197.73 198.34
6 0 0 0 0 0 0 0 0 0
7 -11.06 -11.06 -11.06 -11.07 -11.09 -11.09 -11.14 -11.18 -11.2

Total Poh 978.04 978.51 978.91 984.63 990.66 991.6 1005.9 1020.2 1028.5

EPC Contractor-M/s Krishna Constructions 25


Design ch-109+720
Design of PSC Girder

Forces after Friction & Slip Loss : (Vertical Component)


Sections c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Cable- No.
1 5.3109 5.3134 5.3155 4.7406 4.0824 3.9794 2.4164 0.8434 0
2 5.3109 5.3134 5.3155 4.7406 4.0824 3.9794 2.4164 0.8434 0
3 10.621 10.626 10.63 9.476 8.1547 7.948 4.8101 1.6722 0
4 22.768 22.778 22.788 20.316 17.485 17.043 10.321 3.6002 0
5 29.437 29.451 29.463 26.27 22.614 22.042 13.36 4.6774 0
6 0 0 0 0 0 0 0 0 0
7 -1.751 -1.751 -1.751 -1.56 -1.342 -1.308 -0.79 -0.272 0

Total Poh 71.696 71.73 71.761 63.982 55.077 53.684 32.534 11.365 0

Cable Ordinate From Soffit of Girder :


Sections c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Cable- No.
1 0.2913 0.2867 0.2826 0.2466 0.2149 0.2104 0.1561 0.1286 0.125
2 0.2913 0.2867 0.2826 0.2466 0.2149 0.2104 0.1561 0.1286 0.125
3 0.7665 0.7486 0.7329 0.5939 0.4718 0.4544 0.2449 0.1391 0.125
4 1.2516 1.2258 1.2031 1.0023 0.826 0.8008 0.4982 0.3453 0.325
5 1.7366 1.7029 1.6733 1.4107 1.1801 1.1472 0.7515 0.5516 0.525
6 1.7366 1.7029 1.6733 1.4107 1.1801 1.1472 0.7515 0.5516 0.525
7 1.7366 1.7029 1.6733 1.4107 1.1801 1.1472 0.7515 0.5516 0.525

EPC Contractor-M/s Krishna Constructions 26


Design ch-109+720
Design of PSC Girder

Calculation of Friction & Slip Losses for all Cables :

Cable No. & Jacking Force


Cb. No. Strands % Jack Slip As Jack F Emergence angle Calculated Slip Total length of cableElongation
no. % mm mm2 Tonne Deg. mm m mm
1 19 100 6 1875.49 267.007 1.24536 6.00021 36.2027 129.673
2 19 100 6 1875.49 267.007 1.24536 6.00021 36.2027 129.673
3 10 100 6 987.1 140.53 4.79309 6.00012 36.24 129.1
4 15 100 6 1480.65 210.795 6.90591 5.99951 36.2834 128.835
5 15 100 6 1480.65 210.795 9.00004 5.99984 36.3424 128.631
6 0 0 0 0 0 9.00004 0 36.3424 0
7 0 0 0 0 0 0 5.23445 36.3424 0

Cable NO. 1
Change in Angle due to : Change in Angle due to :
Vertical Profile Horizontal Profile
x (O) x(J1) Curve y a1 da1 Sda1 x (O) x(J1) Curve z a2 da2 Sda2
17.1 0 0.3 0.02174 0 17.1 0 0.2 0 0
16.1 1 Linear 0.27826 0.02174 0 0 16.1 1 Linear 0.2 0 0 0
5 12.1 Parab. 0.13194 0.00463 0.01711 0.01711 5 12.1 Linear 0.2 0 0 0
3 14.1 Parab. 0.12577 0.00154 0.00308 0.02019 3 14.1 Rev.Parab. 0.2 0 0 0
2 15.1 Parab. 0.125 0 0.00154 0.02174 2 15.1 Parab. 0.2 0 0 0
0 17.1 Linear 0.125 0 0 0.02174 0 17.1 Linear 0.2 0 0 0

Friction Effect
x(J1) a1 +a2 m*a k*x - (ma +k*x) P1(x) = Po* Avg. e-(mq+Kx)
prestress Cable Length
0 0 0 0 0 267.007
1 0 0 0.002 -0.002 266.473 266.74 1
12.1 0.01711 0.00291 0.0242 -0.027108767 259.866 263.17 11.1
14.1 0.02019 0.00343 0.0282 -0.031632967 258.693 259.279 2
15.1 0.02174 0.0037 0.0302 -0.03389507 258.108 258.401 1
17.1 0.02174 0.0037 0.0342 -0.03789507 257.078 257.593 2

Extension of cable calculation :


Weighted avg. force in cable after friction loss = 261.992 tonne
Length of cable from Null point (i.e. 0.5L)
1) Plan length of cable = 17.1 m
2) Extra length on account of vertical profile
a) Linear portion = 0m
b) Parabolic portion = 0.00111 m
c) Linear portion = 0.00024 m
3) Extra length on account of horizontal profile
a) Linear portion = 0 m
b) Parabolic portion = 0 m
c) Reverse Parabola = 0
c) Linear portion = 0 m
4) Extra Length of cable = 1 m *(assumed)

Total = 18.1013 m

Extension at Each end = P*L = 261.992 x 18.1013 x 10^7


A * Es 1875.49 x 195000

= 129.673 mm

EPC Contractor-M/s Krishna Constructions 27


Design ch-109+720
Design of PSC Girder

Calculation of Slip :
Slip allowable = 6 mm
Say slip travels up to > 17.1 m 3.004
x(J1) Po(x) P1(x) (Po - P1) /2 1/2 Shaded Area
0 267.007 244.145 11.43093008
1 266.473 244.679 10.89744984 11.1642
12.1 259.866 251.286 4.289930181 84.29
14.1 258.693 252.459 3.116900024 7.40683
15.1 258.108 253.044 2.532371437 2.82464
17.1 257.078 254.074 1.502 4.03437

Total = 109.72
Total Shaded
219.44
area =

Po(x) = Force after friction loss at distance x


P1(x) = Force after slip loss at distance x

slip = Shaded area / (A* E)


A*E = 36572.1 Tonne

slip = 219440 = 6.00021 mm OK


36572.1

Pre-stress Force after Friction & slip Losses :


x(J1) P1(x) Length Avg. force a in elev. a in Plan. P1h P1v P1z P0h P0v P0z
m Tonne m (tonne) rad. rad. Tonne Tonne Tonne Tonne Tonne Tonne
0 244.145 0.02174 0 244.087 5.30625 0 266.944 5.80313 0
1 244.679 1 244.411827 0.02174 0 244.621 5.31784 0 266.944 5.80313 0
12.1 251.286 11.1 247.982327 0.00463 0 251.283 1.16227 0 267.004 1.23499 0
14.1 252.459 2 251.8726019 0.00154 0 252.459 0.38924 0 267.007 0.41167 0
15.1 253.044 1 252.7513813 0 0 253.044 0 0 267.007 0 0
17.1 254.074 2 253.5588313 0 0 254.074 0 0 267.007 0 0
17.1 254.074 0 254.074017 0 0 254.074 0 0 267.007 0 0

Avearge Pre-stress force after Friction


& slip Losses = 249.16 tonne

270
267.01

265

260
(Prestress)

257.08

255
254.07
250

245
244.15
240 (x)
0 2 4 6 8 10 12 14 16 18
After Friction Loss After slip Loss

EPC Contractor-M/s Krishna Constructions 28


Design ch-109+720
Design of PSC Girder

Cable NO. 2
Change in Angle due to : Change in Angle due to :
Vertical Profile Horizontal Profile
x (O) x(J1) Curve y a1 da1 Sda1 x (O) x(J1) Curve z a2 da2 Sda2
17.1 0 0.3 0.02174 0 17.1 0 -0.2 0 0
16.1 1 Linear 0.27826 0.02174 0 0 16.1 1 Linear -0.2 0 0 0
5 12.1 Parab. 0.13194 0.00463 0.01711 0.01711 5 12.1 Linear -0.2 0 0 0
3 14.1 Parab. 0.12577 0.00154 0.00308 0.02019 3 14.1 Rev.Parab. -0.2 0 0 0
2 15.1 Parab. 0.125 0 0.00154 0.02174 2 15.1 Parab. -0.2 0 0 0
0 17.1 Linear 0.125 0 0 0.02174 0 17.1 Linear -0.2 0 0 0

Friction Effect
x(J1) a1 +a2 m*a k*x - (ma +k*x) P1(x) = Po *e-(mq + Kx)
Avg. prestress Cable Length
0 0 0 0 0 267.007
1 0 0 0.002 -0.002 266.473 266.74 1
12.1 0.01711 0.00291 0.0242 -0.027108767 259.866 263.17 11.1
14.1 0.02019 0.00343 0.0282 -0.031632967 258.693 259.279 2
15.1 0.02174 0.0037 0.0302 -0.03389507 258.108 258.401 1
17.1 0.02174 0.0037 0.0342 -0.03789507 257.078 257.593 2

Extension of cable calculation :


Weighted Avg. force in cable after friction loss = 261.992 tonne
Length of cable from Null point (i.e. 0.5L)
1) Plan length of cable = 17.1 m
2) Extra length on account of vertical profile
a) Linear portion = 0m
b) Parabolic portion = 0.00111 m
c) Linear portion = 0.00024 m
3) Extra length on account of horizontal profile
a) Linear portion = 0 m
b) Parabolic portion = 0 m
c) Reverse Parabola = 0
c) Linear portion = 0 m
4) Extra Length of cable = 1 m *(assumed)

Total = 18.1013 m

Extension at Each end = P*L = 261.992 x 18.1013 x 10^7


A * Es 1875.49 x 195000

= 129.673 mm

Calculation of Slip :
Slip allowable = 6 mm
Say slip travels up to > 17.1 m 3.004
x(J1) Po(x) P1(x) (Po - P1) /2 1/2 Shaded Area
0 267.007 244.145 11.43093008
1 266.473 244.679 10.89744984 11.1642
12.1 259.866 251.286 4.289930181 84.29
14.1 258.693 252.459 3.116900024 7.40683
15.1 258.108 253.044 2.532371437 2.82464
17.1 257.078 254.074 1.502 4.03437

Total = 109.72
Total Shaded
219.44
area =

EPC Contractor-M/s Krishna Constructions 29


Design ch-109+720
Design of PSC Girder

Po(x) = Force after friction loss at distance x


P1(x) = Force after slip loss at distance x

slip = Shaded area / (A* E)


A*E = 36572.1 Tonne

slip = 219440 = 6.00021 mm OK


36572.1

Pre-stress Force after Friction & slip Losses :


x(J1) P1(x) Length Avg. force a in elev. a in Plan. P1h P1v P1z P0h P0v P0z
m Tonne m (tonne rad. rad. Tonne Tonne Tonne Tonne Tonne Tonne
0 244.145 0.02174 0 244.087 5.30625 0 266.944 5.80313 0
1 244.679 1 244.411827 0.02174 0 244.621 5.31784 0 266.944 5.80313 0
12.1 251.286 11.1 247.982327 0.00463 0 251.283 1.16227 0 267.004 1.23499 0
14.1 252.459 2 251.8726019 0.00154 0 252.459 0.38924 0 267.007 0.41167 0
15.1 253.044 1 252.7513813 0 0 253.044 0 0 267.007 0 0
17.1 254.074 2 253.5588313 0 0 254.074 0 0 267.007 0 0
17.1 254.074 0 254.074017 0 0 254.074 0 0 267.007 0 0

Avearge Pre-stress force after Friction


& slip Losses = 249.16 tonne

270
267.01
265
(Prestress)

260
257.08

255
254.07

250

245
244.15
(x)
240
0 2 4 6 8 10 12 14 16 18
After Friction Loss After slip Loss

Cable NO. 3
Change in Angle due to : Change in Angle due to :
Vertical Profile Horizontal Profile
x (O) x(J1) Curve y a1 da1 Sda1 x (O) x(J1) Curve z a2 da2 Sda2
17.1 0 0.8 0.08366 0 17.1 0 0 0 0
16.1 1 Linear 0.71615 0.08366 0 0 16.1 1 Linear 0 0 0 0
3 14.1 Parab. 0.12797 0.00595 0.07771 0.07771 3 14.1 Linear 0 0 0 0
2 15.1 Parab. 0.125 0 0.00595 0.08366 2 15.1 Rev.Parab. 0 0 0 0
2 15.1 Parab. 0.125 0 0 0.08366 2 15.1 Rev.Parab. 0 0 0 0
0 17.1 Linear 0.125 0 0 0.08366 0 17.1 Linear 0 0 0 0

Friction Effect
x(J1) a1 +a2 m*a k*x - (ma +k*x) P1(x) = Po *e-(mq + Kx)
Avg. prestress Cable Length
0 0 0 0 0 140.53
1 0 0 0.002 -0.002 140.249 140.39 1
14.1 0.07771 0.01321 0.0282 -0.041410434 134.829 137.539 13.1
15.1 0.08366 0.01422 0.0302 -0.044421391 134.424 134.627 1
15.1 0.08366 0.01422 0.0302 -0.044421391 134.424 134.424 0
17.1 0.08366 0.01422 0.0342 -0.048421391 133.887 134.156 2

EPC Contractor-M/s Krishna Constructions 30


Design ch-109+720
Design of PSC Girder

Extension of cable calculation :


Weighted Avg. force in cable after friction loss = 137.14 tonne
Length of cable from Null point (i.e. 0.5L)
1) Plan length of cable = 17.1 m
2) Extra length on account of vertical profile
a) Linear portion = 0m
b) Parabolic portion = 0.01651 m
c) Linear portion = 0.00351 m
3) Extra length on account of horizontal profile
a) Linear portion = 0 m
b) Parabolic portion = 0 m
c) Reverse Parabola = 0
c) Linear portion = 0 m
4) Extra Length of cable = 1 m *(assumed)

Total = 18.12 m

Extension at Each end = P*L = 137.14 x 18.12 x 10^7


A * Es 987.1 x 195000

= 129.1 mm

Calculation of Slip :
Slip allowable = 6 mm
Say slip travels up to > 17.1 m 0.249
x(J1) Po(x) P1(x) (Po - P1) /2 1/2 Shaded Area
0 140.53 126.996 6.767038385
1 140.249 127.277 6.486259313 6.62665
14.1 134.829 132.696 1.066477232 49.4704
15.1 134.424 133.102 0.661122264 0.8638
15.1 134.424 133.102 0.661122264 0
17.1 133.887 133.638 0.1245 0.78562

Total = 57.7465
Total Shaded
115.493
area =

Po(x) = Force after friction loss at distance x


P1(x) = Force after slip loss at distance x

slip = Shaded area / (A* E)


A*E = 19248.5 Tonne

slip = 115493 = 6.00012 mm OK


19248.5

Pre-stress Force after Friction & slip Losses :


x(J1) P1(x) Length Avg. force a in elev. a in Plan. P1h P1v P1z P0h P0v P0z
m Tonne m (tonne rad. rad. Tonne Tonne Tonne Tonne Tonne Tonne
0 126.996 0.08366 0 126.552 10.6115 0 140.039 11.7424 0
1 127.277 1 127.1362849 0.08366 0 126.832 10.6349 0 140.039 11.7424 0
14.1 132.696 13.1 129.9865655 0.00595 0 132.694 0.78912 0 140.527 0.8357 0
15.1 133.102 1 132.899134 0 0 133.102 0 0 140.53 0 0
15.1 133.102 0 133.1018115 0 0 133.102 0 0 140.53 0 0
17.1 133.638 2 133.3701226 0 0 133.638 0 0 140.53 0 0
17.1 133.638 0 133.6384338 0 0 133.638 0 0 140.53 0 0

EPC Contractor-M/s Krishna Constructions 31


Design ch-109+720
Design of PSC Girder

Avearge Pre-stress force after Friction


& slip Losses = 130.386 tonne

145

140.53
140
(Prestress)

133.89
135
133.64

130
127.00

(x)
125
0 2 4 6 8 10 12 14 16 18
After Friction Loss After slip Loss

Cable NO. 4
Change in Angle due to : Change in Angle due to :
Vertical Profile Horizontal Profile
x (O) x(J1) Curve y a1 da1 Sda1 x (O) x(J1) Curve z a2 da2 Sda2
17.1 0 1.3 0.12053 0 17.1 0 0 0 0
16.1 1 Linear 1.17888 0.12053 0 0 16.1 1 Linear 0 0 0 0
3 14.1 Parab. 0.32929 0.00859 0.11194 0.11194 3 14.1 Linear 0 0 0 0
2 15.1 Parab. 0.325 0 0.00859 0.12053 2 15.1 Rev.Parab. 0 0 0 0
2 15.1 Parab. 0.325 0 0 0.12053 2 15.1 Rev.Parab. 0 0 0 0
0 17.1 Linear 0.325 0 0 0.12053 0 17.1 Linear 0 0 0 0

Friction Effect
x(J1) a1 +a2 m*a k*x - (ma +k*x) P1(x) = Po *e-(mq + Kx)
Avg. prestress Cable Length
0 0 0 0 0 210.795
1 0 0 0.002 -0.002 210.374 210.584 1
14.1 0.11194 0.01903 0.0282 -0.047230004 201.071 205.722 13.1
15.1 0.12053 0.02049 0.0302 -0.050690257 200.376 200.723 1
15.1 0.12053 0.02049 0.0302 -0.050690257 200.376 200.376 0
17.1 0.12053 0.02049 0.0342 -0.054690257 199.576 199.976 2

Extension of cable calculation :


Weighted Avg. force in cable after friction loss = 205.042 tonne
Length of cable from Null point (i.e. 0.5L)
1) Plan length of cable = 17.1 m
2) Extra length on account of vertical profile
a) Linear portion = 0m
b) Parabolic portion = 0.0344 m
c) Linear portion = 0.00731 m
3) Extra length on account of horizontal profile
a) Linear portion = 0 m
b) Parabolic portion = 0 m
c) Reverse Parabola = 0
c) Linear portion = 0 m
4) Extra Length of cable = 1 m *(assumed)

Total = 18.1417 m

Extension at Each end = P*L = 205.042 x 18.1417 x 10^7


A * Es 1480.65 x 195000

= 128.835 mm

EPC Contractor-M/s Krishna Constructions 32


Design ch-109+720
Design of PSC Girder

Calculation of Slip :
Slip allowable = 6 mm
Say slip travels up to = 16.066 m -1.034
x(J1) Po(x) P1(x) (Po - P1) /2 1/2 Shaded Area
0 210.795 189.184 10.80530327
1 210.374 189.606 10.38413466 10.5947
14.1 201.071 198.909 1.080905715 75.096
15.1 200.376 199.603 0.386353226 0.73363
15.1 200.376 199.603 0.386353226 0
16.066 199.99 199.99 0 0.18661

Total = 86.611
Total Shaded
173.222
area =

Po(x) = Force after friction loss at distance x


P1(x) = Force after slip loss at distance x

slip = Shaded area / (A* E)


A*E = 28872.7 Tonne

slip = 173222 = 5.99951 mm OK


28872.7

Pre-stress Force after Friction & slip Losses :


x(J1) P1(x) Length Avg. force a in elev. a in Plan. P1h P1v P1z P0h P0v P0z
m Tonne m (tonne rad. rad. Tonne Tonne Tonne Tonne Tonne Tonne
0 189.184 0.12053 0 187.812 22.7474 0 209.266 25.3458 0
1 189.606 1 189.394936 0.12053 0 188.23 22.798 0 209.266 25.3458 0
14.1 198.909 13.1 194.2571348 0.00859 0 198.901 1.70855 0 210.787 1.81065 0
15.1 199.603 1 199.2560255 0 0 199.603 0 0 210.795 0 0
15.1 199.603 0 199.6033017 0 0 199.603 0 0 210.795 0 0
16.066 199.99 0.966 199.7964783 0 0 199.99 0 0 210.795 0 0
17.1 199.576 1.034 199.78288 0 0 199.576 0 0 210.795 0 0

Avearge Pre-stress force after Friction


& slip Losses = 194.912 tonne

215
210.79
210
(Prestress)

205

200 199.58
199.99

195

190 189.18

185 (x)

0 2 4 6 8 10 12 14 16 18
After Friction Loss After slip Loss

EPC Contractor-M/s Krishna Constructions 33


Design ch-109+720
Design of PSC Girder

Cable NO. 5
Change in Angle due to : Change in Angle due to :
Vertical Profile Horizontal Profile
x (O) x(J1) Curve y a1 da1 Sda1 x (O) x(J1) Curve z a2 da2 Sda2
17.1 0 1.8 0.15708 0 17.1 0 0 0 0
16.1 1 Linear 1.64161 0.15708 0 0 16.1 1 Linear 0 0 0 0
3 14.1 Parab. 0.53062 0.01123 0.14585 0.14585 3 14.1 Linear 0 0 0 0
2 15.1 Parab. 0.525 0 0.01123 0.15708 2 15.1 Rev.Parab. 0 0 0 0
2 15.1 Parab. 0.525 0 0 0.15708 2 15.1 Rev.Parab. 0 0 0 0
0 17.1 Linear 0.525 0 0 0.15708 0 17.1 Linear 0 0 0 0

Friction Effect
x(J1) a1 +a2 m*a k*x - (ma +k*x) P1(x) = Po *e-(mq + Kx)
Avg. prestress Cable Length
0 0 0 0 0 210.795
1 0 0 0.002 -0.002 210.374 210.584 1
14.1 0.14585 0.02479 0.0282 -0.052994119 199.915 205.144 13.1
15.1 0.15708 0.0267 0.0302 -0.056903646 199.135 199.525 1
15.1 0.15708 0.0267 0.0302 -0.056903646 199.135 199.135 0
17.1 0.15708 0.0267 0.0342 -0.060903646 198.34 198.737 2

Extension of cable calculation :


Weighted Avg. force in cable after friction loss = 204.384 tonne
Length of cable from Null point (i.e. 0.5L)
1) Plan length of cable = 17.1 m
2) Extra length on account of vertical profile
a) Linear portion = 0m
b) Parabolic portion = 0.05873 m
c) Linear portion = 0.01247 m
3) Extra length on account of horizontal profile
a) Linear portion = 0 m
b) Parabolic portion = 0 m
c) Reverse Parabola = 0
c) Linear portion = 0 m
4) Extra Length of cable = 1 m *(assumed)

Total = 18.1712 m

Extension at Each end = P*L = 204.384 x 18.1712 x 10^7


A * Es 1480.65 x 195000

= 128.631 mm

Calculation of Slip :
Slip allowable = 6 mm
Say slip travels up to = 14.761 m -2.339
x(J1) Po(x) P1(x) (Po - P1) /2 1/2 Shaded Area
0 210.795 188.004 11.39566837
1 210.374 188.425 10.97449976 11.1851
14.1 199.915 198.884 0.515611028 75.2602
14.761 199.399 199.399 0 0.17041
14.761 199.399 199.399 0 0
14.761 199.399 199.399 0 0

Total = 86.6157
Total Shaded
173.231
area =

EPC Contractor-M/s Krishna Constructions 34


Design ch-109+720
Design of PSC Girder

Po(x) = Force after friction loss at distance x


P1(x) = Force after slip loss at distance x

slip = Shaded area / (A* E)


A*E = 28872.7 Tonne

slip = 173231 = 5.99984 mm OK


28872.7

Pre-stress Force after Friction & slip Losses :


x(J1) P1(x) Length Avg. force a in elev. a in Plan. P1h P1v P1z P0h P0v P0z
m Tonne m (tonne rad. rad. Tonne Tonne Tonne Tonne Tonne Tonne
0 188.004 0.15708 0 185.689 29.4104 0 208.2 32.9757 0
1 188.425 1 188.2142058 0.15708 0 186.105 29.4762 0 208.2 32.9757 0
14.1 198.884 13.1 193.6542345 0.01123 0 198.871 2.23392 0 210.782 2.36771 0
14.761 199.399 0.661 199.1414843 0.00381 0 199.398 0.7593 0 210.793 0.8027 0
15.1 199.135 0.339 199.2670719 0 0 199.135 0 0 210.795 0 0
15.1 199.135 0 199.1348539 0 0 199.135 0 0 210.795 0 0
17.1 198.34 2 198.7373797 0 0 198.34 0 0 210.795 0 0

Avearge Pre-stress force after Friction


& slip Losses = 194.254 tonne

215

210.79
210

205
(Prestress)

200
198.34
199.13

195

190 188.00
(x)

185

0 2 4 6 8 10 12 14 16 18

After Friction Loss After slip Loss

Cable NO. 6
Change in Angle due to : Change in Angle due to :
Vertical Profile Horizontal Profile
x (O) x(J1) Curve y a1 da1 Sda1 x (O) x(J1) Curve z a2 da2 Sda2
17.1 0 1.8 0.15708 0 17.1 0 0 0 0
16.1 1 Linear 1.64161 0.15708 0 0 16.1 1 Linear 0 0 0 0
3 14.1 Parab. 0.53062 0.01123 0.14585 0.14585 3 14.1 Linear 0 0 0 0
2 15.1 Parab. 0.525 0 0.01123 0.15708 2 15.1 Rev.Parab. 0 0 0 0
2 15.1 Parab. 0.525 0 0 0.15708 2 15.1 Rev.Parab. 0 0 0 0
0 17.1 Linear 0.525 0 0 0.15708 0 17.1 Linear 0 0 0 0

Friction Effect
x(J1) a1 +a2 m*a k*x - (ma +k*x) P1(x) = Po *e-(mq + Kx)
Avg. prestress Cable Length
0 0 0 0 0 0
1 0 0 0.002 -0.002 0 0 1
14.1 0.14585 0.02479 0.0282 -0.052994119 0 0 13.1
15.1 0.15708 0.0267 0.0302 -0.056903646 0 0 1
15.1 0.15708 0.0267 0.0302 -0.056903646 0 0 0
17.1 0.15708 0.0267 0.0342 -0.060903646 0 0 2

EPC Contractor-M/s Krishna Constructions 35


Design ch-109+720
Design of PSC Girder

Extension of cable calculation :


Weighted Avg. force in cable after friction loss = 0 tonne
Length of cable from Null point (i.e. 0.5L)
1) Plan length of cable = 17.1 m
2) Extra length on account of vertical profile
a) Linear portion = 0m
b) Parabolic portion = 0.05873 m
c) Linear portion = 0.01247 m
3) Extra length on account of horizontal profile
a) Linear portion = 0 m
b) Parabolic portion = 0 m
c) Reverse Parabola = 0
c) Linear portion = 0 m
4) Extra Length of cable = 1 m *(assumed)

Total = 18.1712 m

Extension at Each end = P*L = 0x 18.1712 x 10^7


A * Es 1875.49 x 195000

= 0 mm

Calculation of Slip :
Slip allowable = 0 mm
Say slip travels up to = 14.7615 m -2.3385
x(J1) Po(x) P1(x) (Po - P1) /2 1/2 Shaded Area
0 0 0 0
1 0 0 0 0
14.1 0 0 0 0
14.7615 0 0 0 0
14.7615 0 0 0 0
14.7615 0 0 0 0

Total = 0
Total Shaded area0 =

Po(x) = Force after friction loss at distance x


P1(x) = Force after slip loss at distance x

slip = Shaded area / (A* E)


A*E = 36572.1 Tonne

slip = 0= 0 mm OK
36572.1

Pre-stress Force after Friction & slip Losses :


x(J1) P1(x) Length Avg. force a in elev. a in Plan. P1h P1v P1z P0h P0v P0z
m Tonne m (tonne rad. rad. Tonne Tonne Tonne Tonne Tonne Tonne
0 0 0.15708 0 0 0 0 0 0 0
1 0 1 0 0.15708 0 0 0 0 0 0 0
14.1 0 13.1 0 0.01123 0 0 0 0 0 0 0
14.7615 0 0.6615 0 0.0038 0 0 0 0 0 0 0
15.1 0 0.3385 0 0 0 0 0 0 0 0 0
15.1 0 0 0 0 0 0 0 0 0 0 0
17.1 0 2 0 0 0 0 0 0 0 0 0

EPC Contractor-M/s Krishna Constructions 36


Design ch-109+720
Design of PSC Girder

Avearge Pre-stress force after Friction


& slip Losses = 0 tonne

5
(Prestress)

0 0.00 (x) 0.00


0.00
0 2 4 6 8 10 12 14 16 18
After Friction Loss After slip Loss

Cable NO. 7
Change in Angle due to : Change in Angle due to :
Vertical Profile Horizontal Profile
x (O) x(J1) Curve y a1 da1 Sda1 x (O) x(J1) Curve z a2 da2 Sda2
17.1 0 1.8 0.15708 0 17.1 0 0 0 0
16.1 1 Linear 1.64161 0.15708 0 0 16.1 1 Linear 0 0 0 0
3 14.1 Parab. 0.53062 0.01123 0.14585 0.14585 3 14.1 Linear 0 0 0 0
2 15.1 Parab. 0.525 0 0.01123 0.15708 2 15.1 Rev.Parab. 0 0 0 0
2 15.1 Parab. 0.525 0 0 0.15708 2 15.1 Rev.Parab. 0 0 0 0
0 17.1 Linear 0.525 0 0 0.15708 0 17.1 Linear 0 0 0 0

Friction Effect
x(J1) a1 +a2 m*a k*x - (ma +k*x) P1(x) = Po *e-(mq + Kx)
Avg. prestress Cable Length
0 0 0 0 0 0
1 0 0 0.002 -0.002 0 0 1
14.1 0.14585 0.02479 0.0282 -0.052994119 0 0 13.1
15.1 0.15708 0.0267 0.0302 -0.056903646 0 0 1
15.1 0.15708 0.0267 0.0302 -0.056903646 0 0 0
17.1 0.15708 0.0267 0.0342 -0.060903646 0 0 2

Extension of cable calculation :


Weighted Avg. force in cable after friction loss = 0 tonne
Length of cable from Null point (i.e. 0.5L)
1) Plan length of cable = 17.1 m
2) Extra length on account of vertical profile
a) Linear portion = 0m
b) Parabolic portion = 0.05873 m
c) Linear portion = 0.01247 m
3) Extra length on account of horizontal profile
a) Linear portion = 0 m
b) Parabolic portion = 0 m
c) Reverse Parabola = 0 m
c) Linear portion = 0 m
4) Extra Length of cable = 1 m *(assumed)

Total = 18.1712 m

Extension at Each end = P*L = 0x 18.1712 x 10^7


A * Es 1875.49 x 195000

= 0 mm

EPC Contractor-M/s Krishna Constructions 37


Design ch-109+720
Design of PSC Girder

Calculation of Slip :
Slip allowable = 0 mm
Say slip travels up to > 17.1 m 11.195
x(J1) Po(x) P1(x) (Po - P1) /2 1/2 Shaded Area
0 0 -11.195 5.5975
1 0 -11.195 5.5975 5.5975
14.1 0 -11.195 5.5975 73.3273
15.1 0 -11.195 5.5975 5.5975
15.1 0 -11.195 5.5975 0
17.1 0 -11.195 5.5975 11.195

Total = 95.7173
Total Shaded
191.435
area =

Po(x) = Force after friction loss at distance x


P1(x) = Force after slip loss at distance x

slip = Shaded area / (A* E)


A*E = 36572.1 Tonne

slip = 191435 = 5.23445 mm Check Travel Length of slip


36572.1

Pre-stress Force after Friction & slip Losses :


x(J1) P1(x) Length Avg. force a in elev. a in Plan. P1h P1v P1z P0h P0v P0z
m Tonne m (tonne rad. rad. Tonne Tonne Tonne Tonne Tonne Tonne
0 -11.195 0.15708 0 -11.057 -1.7513 0 0 0 0
1 -11.195 1 -11.195 0.15708 0 -11.057 -1.7513 0 0 0 0
14.1 -11.195 13.1 -11.195 0.01123 0 -11.194 -0.1257 0 0 0 0
15.1 -11.195 1 -11.195 0 0 -11.195 0 0 0 0 0
15.1 -11.195 0 -11.195 0 0 -11.195 0 0 0 0 0
17.1 -11.195 2 -11.195 0 0 -11.195 0 0 0 0 0
17.1 -11.195 0 -11.195 0 0 -11.195 0 0 0 0 0

Avearge Pre-stress force after Friction


& slip Losses = -11.195 tonne

0 0.00 0.00
0 2 4 6 8 10 12 14 16 18

-5
(Prestress)

-10
-11.20
-11.20

-15 (x)

After Friction Loss After slip Loss

EPC Contractor-M/s Krishna Constructions 38


Design ch-109+720
Design of PSC Girder

Summary of Pre-stressing forces before friction & slip loss :


Cable NO : 1 Cable NO. 2 Cable NO : 3
x(J1) Po(x) Poh(x) Pov(x) x(J1) Po(x) Poh(x) Pov(x) x(J1) Po(x) Poh(x) Pov(x)
m Tonne Tonne Tonne m Tonne Tonne Tonne m Tonne Tonne Tonne
0 267.007 266.944 5.80313 0 267.007 266.944 5.80313 0 140.53 140.039 11.7424
1 267.007 266.944 5.80313 1 267.007 266.944 5.80313 1 140.53 140.039 11.7424
12.1 267.007 267.004 1.23499 12.1 267.007 267.004 1.23499 14.1 140.53 140.527 0.8357
14.1 267.007 267.007 0.41167 14.1 267.007 267.007 0.41167 15.1 140.53 140.53 0
15.1 267.007 267.007 0 15.1 267.007 267.007 0 15.1 140.53 140.53 0
17.1 267.007 267.007 0 17.1 267.007 267.007 0 17.1 140.53 140.53 0
17.1 267.007 267.007 0 17.1 267.007 267.007 0 17.1 140.53 140.53 0

Cable NO : 4 Cable NO : 5 Cable NO : 6


x(J1) Po(x) Poh(x) Pov(x) x(J1) Po(x) Poh(x) Pov(x) x(J1) Po(x) Poh(x) Pov(x)
m Tonne Tonne Tonne m Tonne Tonne Tonne m Tonne Tonne Tonne
0 210.795 209.266 25.3458 0 210.795 208.2 32.9757 0 0 0 0
1 210.795 209.266 25.3458 1 210.795 208.2 32.9757 1 0 0 0
14.1 210.795 210.787 1.81065 14.1 210.795 210.782 2.36771 14.1 0 0 0
15.1 210.795 210.795 0 14.761 210.795 210.793 0.8027 14.7615 0 0 0
15.1 210.795 210.795 0 15.1 210.795 210.795 0 15.1 0 0 0
16.066 210.795 210.795 0 15.1 210.795 210.795 0 15.1 0 0 0
17.1 210.795 210.795 0 17.1 210.795 210.795 0 17.1 0 0 0

Cable NO : 7
x(J1) Po(x) Poh(x) Pov(x)
m Tonne Tonne Tonne
0 0 0 0
1 0 0 0
14.1 0 0 0
15.1 0 0 0
15.1 0 0 0
17.1 0 0 0
17.1 0 0 0

Summary of pre-stressing forces after friction & slip loss :


Cable NO : 1 Cable NO. 2 Cable NO : 3
x(J1) P1(x) P1h(x) P1v(x) x(J1) P1(x) P1h(x) P1v(x) x(J1) P1(x) P1h(x) P1v(x)
m Tonne Tonne Tonne m Tonne Tonne Tonne m Tonne Tonne Tonne
0 244.145 244.087 5.30625 0 244.145 244.087 5.30625 0 126.996 126.552 10.6115
1 244.679 244.621 5.31784 1 244.679 244.621 5.31784 1 127.277 126.832 10.6349
12.1 251.286 251.283 1.16227 12.1 251.286 251.283 1.16227 14.1 132.696 132.694 0.78912
14.1 252.459 252.459 0.38924 14.1 252.459 252.459 0.38924 15.1 133.102 133.102 0
15.1 253.044 253.044 0 15.1 253.044 253.044 0 15.1 133.102 133.102 0
17.1 254.074 254.074 0 17.1 254.074 254.074 0 17.1 133.638 133.638 0
17.1 254.074 254.074 0 17.1 254.074 254.074 0 17.1 133.638 133.638 0

EPC Contractor-M/s Krishna Constructions 39


Design ch-109+720
Design of PSC Girder

Cable NO : 4 Cable NO : 5 Cable NO : 6


x(J1) P1(x) P1h(x) P1v(x) x(J1) P1(x) P1h(x) P1v(x) x(J1) P1(x) P1h(x) P1v(x)
m Tonne Tonne Tonne m Tonne Tonne Tonne m Tonne Tonne Tonne
0 189.184 187.812 22.7474 0 188.004 185.689 29.4104 0 0 0 0
1 189.606 188.23 22.798 1 188.425 186.105 29.4762 1 0 0 0
14.1 198.909 198.901 1.70855 14.1 198.884 198.871 2.23392 14.1 0 0 0
15.1 199.603 199.603 0 14.761 199.399 199.398 0.7593 14.7615 0 0 0
15.1 199.603 199.603 0 15.1 199.135 199.135 0 15.1 0 0 0
16.066 199.99 199.99 0 15.1 199.135 199.135 0 15.1 0 0 0
17.1 199.576 199.576 0 17.1 198.34 198.34 0 17.1 0 0 0

Cable NO : 7
x(J1) P1(x) P1h(x) P1v(x)
m Tonne Tonne Tonne
0 -11.195 -11.0572 -1.7513
1 -11.195 -11.0572 -1.7513
14.1 -11.195 -11.1943 -0.1257
15.1 -11.195 -11.195 0
15.1 -11.195 -11.195 0
17.1 -11.195 -11.195 0
17.1 -11.195 -11.195 0

EPC Contractor-M/s Krishna Constructions 40


Design ch-109+720
Design of PSC Girder

Pre-stress loss calculation from Stage I prestressing to Stage II prestressing :


Stage : 1
At day 14 Action : Prestressing of stage I cables

Total Nos. of strand stressed : 48 Nos.


Crosssectional area of cables Ap : 4738.1 mm2
UTS of cables : 881.76 Tonne
Modulus of Elasticity of pre-stressing steel Ep : 195000 N/mm2

SECTION PROPERTIES
Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Section at 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Properties of Precast Section
Area m2 1.9297 1.9297 1.9297 1.4394 0.9447 0.9447 0.9447 0.9447 0.9447
I gross m4 0.872 0.872 0.872 0.7401 0.6069 0.6069 0.6069 0.6069 0.6069
yb m 1.1677 1.1677 1.1677 1.16 1.1524 1.1524 1.1524 1.1524 1.1524

Properties of Composite Section


Area m2 2.5025 2.5025 2.5025 2.0122 1.5175 1.5175 1.5175 1.5175 1.5175
I gross m4 1.556 1.556 1.556 1.3655 1.1732 1.1732 1.1732 1.1732 1.1732
yb m 1.452 1.452 1.452 1.5391 1.6271 1.6271 1.6271 1.6271 1.6271

Forces Before Friction & Slip Loss : (Horizontal Component)


Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Length 0.213 0.187 1.742 1.758 0.275 4.175 4.175 4.175
Cable- No.

1 Tonne 266.94 266.94 266.94 266.95 266.96 266.96 266.99 267.01 267.01
2 Tonne 266.94 266.94 266.94 266.95 266.96 266.96 266.99 267.01 267.01
3 Tonne 140.04 140.04 140.04 140.1 140.16 140.17 140.33 140.48 140.53
4 Tonne 0 0 0 0 0 0 0 0 0
5 Tonne 0 0 0 0 0 0 0 0 0

EPC Contractor-M/s Krishna Constructions 41


Design ch-109+720
Design of PSC Girder

Total (P1oh) Tonne 673.93 673.93 673.93 674 674.09 674.1 674.3 674.49 674.54
Weighted Average of pre-stress force Tonne 673.93 673.93 673.96 674.04 674.09 674.2 674.4 674.52

Forces after Friction & Slip Loss : (Horizontal Component)


Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Cable- No.
1 Tonne 244.3 244.41 244.51 245.55 246.6 246.77 249.27 251.77 254.07
2 Tonne 244.3 244.41 244.51 245.55 246.6 246.77 249.27 251.77 254.07
3 Tonne 126.66 126.72 126.78 127.52 128.31 128.43 130.3 132.17 133.64
4 Tonne 0 0 0 0 0 0 0 0 0
5 Tonne 0 0 0 0 0 0 0 0 0

Total (F1h) Tonne 615.27 615.55 615.8 618.61 621.51 621.96 628.85 635.7 641.79
Eccen soffit m 0.3891 0.3818 0.3753 0.3182 0.268 0.2608 0.1745 0.1308 0.125
Pre-stress loss Tonne 58.661 58.374 58.122 55.386 52.574 52.134 45.455 38.789 32.757
% Loss % 8.7044 8.6618 8.6245 8.2175 7.7993 7.7339 6.741 5.7508 4.8562

Prestressing force & their eccentricity from cg. of section of Stage I cables :
Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Section at 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1

Total (F1h) Tonne 615.27 615.55 615.8 618.61 621.51 621.96 628.85 635.7 641.79
eF m 0.7785 0.7859 0.7923 0.8419 0.8844 0.8916 0.9779 1.0215 1.0274
eFc m 1.0629 1.0702 1.0767 1.221 1.3591 1.3663 1.4526 1.4963 1.5021

eF = Eccentricity of pre-stressing force from cg. of precast section


eFc = Eccentricity of pre-stressing force from cg. of composite section

STRESS AT CG. OF CABLES DUE TO EXTERNAL APPLIED FORCES


Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Section at Action m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Load Day

EPC Contractor-M/s Krishna Constructions 42


Design ch-109+720
Design of PSC Girder

External Permanent Forces : (BM)


SG 14 Non Composite Tm 0.7297 -8.6895 -16.778 -84.646 -142.08 -150.3 -253.22 -314.97 -335.55

Stresses at cg. of stage-I cables :


Eccentricity of pre-stressing force from cg. of precast section of stage I cables
eF m 0.7785 0.7859 0.7923 0.8419 0.8844 0.8916 0.9779 1.0215 1.0274
Load Day
SG 14 Non Composite N/mm2 0.0065 -0.0783 -0.1525 -0.9629 -2.0704 -2.208 -4.0799 -5.3015 -5.6801

Material properties :
1) Losses due to Elastic shortening : At day 14
loss in pre-stres force = 0.5*Ep/Ec*sav.*(N-1)*As
N-1 = Total Nos. of cable -1 = 2.5263 Nos
As = Area of one cable = 1875.5 mm2

Modulus of Elasticity of concrete Ec = 31991 N/mm2


Modulus of Elasticity of tendons Ep = 195000 N/mm2

F1h = Horizontal component of pre-stressing force after friction & slip loss
eF = Eccentricity of pre-stressing force from cg. Precast section
eFc = Eccentricity of pre-stressing force from cg. Composite section
sc1 = Stress in Concrete at cg. of pre-stressing force. due to pre-stress
sc2 = Stress in Concrete at cg. of pre-stressing force, due to permanent loads at particular stage.
sc3 = Net stress in Concrete at cg. of pre-stressing force
MSWG = Bending Moment due to selfweight of girder at section x

Forces Left in cables after friction & slip


Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Length 0.213 0.187 1.742 1.758 0.275 4.175 4.175 4.175
F1h Tonne 615.27 615.55 615.8 618.61 621.51 621.96 628.85 635.7 641.79
eF m 0.7785 0.7859 0.7923 0.8419 0.8844 0.8916 0.9779 1.0215 1.0274
eFc m 1.0629 1.0702 1.0767 1.221 1.3591 1.3663 1.4526 1.4963 1.5021
sc N/mm2 7.4649 7.5496 7.6246 10.222 14.589 14.73 16.564 17.66 17.955

Permanent Load stresses sc2 N/mm2 0.0065 -0.0783 -0.1525 -0.9629 -2.0704 -2.208 -4.0799 -5.3015 -5.6801

EPC Contractor-M/s Krishna Constructions 43


Design ch-109+720
Design of PSC Girder

Net stress sc3 N/mm2 7.4714 7.4713 7.4722 9.2589 12.518 12.522 12.485 12.358 12.275
Average stress sc3 7.4714 7.4717 8.3656 10.889 12.52 12.503 12.421 12.317

sav.
Weight average of concrete stresses at cg. of pre-stressing foce. = 11.714 N/mm2
Average loss in pre-stres force = 16.916 Tonne

Pre-stressing force at section after Elastic shortening loss


At day = 14
Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1

F1h' T 598.35 598.64 598.89 601.7 604.6 605.05 611.93 618.79 624.87
eF m 0.7785 0.7859 0.7923 0.8419 0.8844 0.8916 0.9779 1.0215 1.0274

sc1 N/mm2 7.2597 7.3421 7.4152 9.9423 14.192 14.329 16.119 17.19 17.481

Permanent Load stresses sc2 N/mm2 0.0065 -0.0783 -0.1525 -0.9629 -2.0704 -2.208 -4.0799 -5.3015 -5.6801

Net stress sc3 N/mm2 7.2662 7.2638 7.2627 8.9794 12.121 12.121 12.039 11.888 11.801

Time Deepndent losses :


Application of initial pre-stress at = 14 day

Total UTS of cables = 881.76 Tonne


Total time dependent losses due to Creep, Shrinkage & Relaxation.

DPc+s+r = Decs Ep + Dspr + Ep/Ec f(t,to) sc


Ap [ 1+ (Ep/Ece) (Ap/Ac) (1 +Ac /Ic *e^2) ]

The denominator is taken as unity for simplicity


Modified formula for time dependent losses
DPc+s+r = Ap [ Decs Ep + Dspr + Ep/Ec f(t,to) sc ]
Ap = Area of all prestressing tendons. = 4738.1 mm2
Decs = Free shrinkage strain.
Ep = Modulus of elasticity of prestressing steel. = 195000 Mpa

EPC Contractor-M/s Krishna Constructions 44


Design ch-109+720
Design of PSC Girder

Dspr = Variation in stress in the tendons at time t, due to relaxation of the prestressing steel.
Ec = modulus of elasticity of concrete at time t0.
f(t,to) = Creep coefficient at a time t for initial load application at time t0.
sc =
Stress in the concrete adjacent to the tendons due to self-weight, initial prestress and all other quasi-permanent actions where relevant.
Ece = Effective modulus of elasticity of concrete for time t to t0
Ac = Area of the concrete section
Ic = second moment of area of the concrete section
e =
eccentricity of the tendons, i.e. the distance between the centroid of the tendons and the centroid of the concrete section.

Time variable parmeters


Satge Day Concrete strength property
bcc(t) fcm (t) Ecm(t)
Shrinkage Creep
strain factor f(t,to)% Mpa Mpa

Casting of concrete at day 0 3.3E-06 0 0 0


Transfer of pre-stress at day stage-I 14 5.7E-05 0 90.163 45.081 31991
Transfer of pre-stress at day stage -Stage II 28 8.3E-05 0.5742 100 50 33000
Casting of deck -III 35 9.4E-05 0.6466 100 50 33000
Transfer over permanent Brg. - Stage IV 63 0.00013 0.8245 100 50 33000
Placing of SIDL - Stage V 64 0.00013 0.8292 100 50 33000
Open to LL - Stage -VI 92 0.00015 0.9375 100 50 33000
At ∞ 36500 0.00037 1.8755 100 50 33000

Relaxation Loss at different stages:


Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Load applied at an age = 14 Day
Force after ES F1h' T 598.35 598.64 598.89 601.7 604.6 605.05 611.93 618.79 624.87
F1h' / UTS 0.6786 0.6789 0.6792 0.6824 0.6857 0.6862 0.694 0.7018 0.7087
At 1000 Hrs % loss 2.2323 2.2364 2.24 2.2798 2.3209 2.3273 2.4249 2.5354 2.6733
Final at 500000 Hrs. % loss 6.697 6.7092 6.7199 6.8395 6.9627 6.982 7.2746 7.6061 8.0199
Relaxation loss from day 14 To day 28
% loss at day 28 % loss 1.8749 1.8783 1.8813 1.9147 1.9492 1.9546 2.0366 2.1294 2.2452
Dspr Mpa 23.677 23.731 23.779 24.316 24.873 24.961 26.302 27.809 29.611

EPC Contractor-M/s Krishna Constructions 45


Design ch-109+720
Design of PSC Girder

Total Relaxation loss at day 28 Tonne 11.218 11.244 11.267 11.521 11.785 11.826 12.462 13.176 14.03
Additional loss from day 14 to day 28 Tonne 11.218 11.244 11.267 11.521 11.785 11.826 12.462 13.176 14.03

Relaxation loss at day 28 To day 35


% loss at day 35 % loss 2.0109 2.0146 2.0178 2.0537 2.0907 2.0964 2.1843 2.2839 2.4081
Dspr Mpa 25.395 25.453 25.504 26.08 26.678 26.771 28.211 29.827 31.759
Total Relaxation loss at day 35 Tonne 12.032 12.06 12.084 12.357 12.64 12.685 13.366 14.132 15.048
Additional loss from day 28 to day 35 Tonne 0.8139 0.8158 0.8174 0.8359 0.855 0.858 0.9042 0.956 1.0179

Relaxation loss at day 35 To day 63


% loss at day 63 % loss 2.2341 2.2382 2.2418 2.2817 2.3228 2.3292 2.4268 2.5374 2.6755
Dspr Mpa 28.214 28.279 28.336 28.975 29.639 29.744 31.343 33.138 35.285
Total Relaxation loss at day 63 Tonne 13.368 13.399 13.426 13.729 14.043 14.093 14.85 15.701 16.718
Additional loss from day 35 to day 63 Tonne 1.3358 1.3389 1.3416 1.3718 1.4033 1.4082 1.4839 1.5689 1.6706

Relaxation loss at day 63 To day 64


% loss at day 64 % loss 2.2344 2.2385 2.242 2.2819 2.323 2.3294 2.4271 2.5377 2.6758
Dspr Mpa 28.217 28.282 28.339 28.978 29.642 29.747 31.346 33.142 35.288
Total Relaxation loss at day 64 Tonne 13.369 13.4 13.427 13.73 14.045 14.094 14.852 15.703 16.72
Additional loss from day 63 to day 64 Tonne 0.0015 0.0015 0.0015 0.0015 0.0015 0.0015 0.0016 0.0017 0.0018

Relaxation loss at day 64 To day 92


% loss at day 92 % loss 2.2413 2.2453 2.2489 2.2889 2.3302 2.3366 2.4345 2.5455 2.684
Dspr Mpa 28.304 28.369 28.426 29.067 29.734 29.838 31.442 33.244 35.397
Total Relaxation loss at day 92 Tonne 13.411 13.441 13.468 13.772 14.088 14.138 14.898 15.751 16.771
Additional loss from day 64 to day 92 Tonne 0.0411 0.0412 0.0413 0.0422 0.0432 0.0433 0.0456 0.0483 0.0514

Relaxation loss at day 92 To day 36500


% loss at day 36500 % loss 6.697 6.7092 6.7199 6.8395 6.9627 6.982 7.2746 7.6061 8.0199
Dspr Mpa 84.574 84.768 84.939 86.856 88.846 89.159 93.952 99.335 105.77
Total Relaxation loss at day 36500 Tonne 40.072 40.164 40.245 41.153 42.096 42.244 44.515 47.066 50.114
Additional loss from day 92 to day 36500 Tonne 26.661 26.722 26.776 27.381 28.008 28.107 29.618 31.314 33.343

EPC Contractor-M/s Krishna Constructions 46


Design ch-109+720
Design of PSC Girder

Creep Loss at different stages:


Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Load applied at an age = 14 Day
Initial concrete stress sc Mpa 7.2662 7.2638 7.2627 8.9794 12.121 12.121 12.039 11.888 11.801

Crep loss from day 14 To day 28


Creep coefficent at day 28 = 0.5742
Concrete Modulus of elasticity at the time of loading = 31991 Mpa
Total Creep loss at day: 28 T 12.049 12.045 12.043 14.89 20.1 20.1 19.963 19.714 19.569
Additional loss from day 14 to day 28 T 12.049 12.045 12.043 14.89 20.1 20.1 19.963 19.714 19.569

Crep loss from day 28 To day 35


Creep coefficent = 0.6466
Concrete Modulus of elasticity at the time of loading = 31991 Mpa
Total Creep loss at day: 35 T 13.569 13.565 13.563 16.768 22.636 22.636 22.482 22.201 22.038
Additional loss from day 28 to day 35 T 1.52 1.5195 1.5193 1.8784 2.5357 2.5357 2.5185 2.487 2.4688

Crep loss from day 35 To day 63


Creep coefficent = 0.8245
Concrete Modulus of elasticity at the time of loading = 31991 Mpa
Total Creep loss at day: 63 T 17.304 17.298 17.295 21.383 28.866 28.866 28.669 28.311 28.104
Additional loss from day 35 to day 63 T 3.7346 3.7334 3.7328 4.6151 6.23 6.2301 6.1877 6.1103 6.0656

Crep loss from day 63 To day 64


Creep coefficent = 0.8292
Concrete Modulus of elasticity at the time of loading = 31991 Mpa
Total Creep loss at day: 64 T 17.402 17.396 17.394 21.505 29.03 29.03 28.833 28.472 28.264
Additional loss from day 63 to day 64 T 0.0984 0.0984 0.0984 0.1217 0.1642 0.1642 0.1631 0.1611 0.1599

Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1

EPC Contractor-M/s Krishna Constructions 47


Design ch-109+720
Design of PSC Girder

Crep loss from day 64 To day 92


Creep coefficent = 0.9375
Concrete Modulus of elasticity at the time of loading = 31991 Mpa
Total Creep loss at day: 92 T 19.675 19.668 19.665 24.314 32.821 32.821 32.598 32.19 31.955
Additional loss from day 64 to day 92 T 2.2727 2.272 2.2717 2.8086 3.7914 3.7914 3.7656 3.7185 3.6913

Crep loss from day 92 To day 36500


Creep coefficent = 1.8755
Concrete Modulus of elasticity at the time of loading = 31991 Mpa
Total Creep loss at day: 36500 T 39.359 39.346 39.34 48.639 65.658 65.658 65.212 64.396 63.925
Additional loss from day 92 to day 36500 T 19.684 19.678 19.675 24.325 32.837 32.837 32.614 32.206 31.97

Shrinkage Loss at different stages:


Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Stages
Load applied at an age 14

EPC Contractor-M/s Krishna Constructions 48


Design ch-109+720
Design of PSC Girder

Shrinkage loss from day 14 To day 28


Initial shrinkage strain at the time of application of load = 6E-05
Shrinkage strain at day 28 = 8E-05
Total shrinkage loss at day: 28 Tonne 2.4207 2.4207 2.4207 2.4207 2.4207 2.4207 2.4207 2.4207 2.4207
Additional loss from day 14 to day 28 Tonne 2.4207 2.4207 2.4207 2.4207 2.4207 2.4207 2.4207 2.4207 2.4207

Shrinkage loss at day 28 To day 35


Initial shrinkage strain at the time of application of load = 6E-05
Shrinkage strain at day 35 = 9E-05
Total shrinkage loss at day: 35 Tonne 3.4091 3.4091 3.4091 3.4091 3.4091 3.4091 3.4091 3.4091 3.4091
Additional loss from day 28 to day 35 T 0.9884 0.9884 0.9884 0.9884 0.9884 0.9884 0.9884 0.9884 0.9884

Shrinkage loss at day 35 To day 63


Initial shrinkage strain at the time of application of load = 6E-05
Shrinkage strain at day 63 = 0.0001
Total shrinkage loss at day: 63 Tonne 6.5712 6.5712 6.5712 6.5712 6.5712 6.5712 6.5712 6.5712 6.5712
Additional loss from day 35 to day 63 T 3.1621 3.1621 3.1621 3.1621 3.1621 3.1621 3.1621 3.1621 3.1621

Shrinkage loss at day 63 To day 64


Initial shrinkage strain at the time of application of load = 6E-05
Shrinkage strain at day 64 = 0.0001
Total shrinkage loss at day: 64 Tonne 6.6672 6.6672 6.6672 6.6672 6.6672 6.6672 6.6672 6.6672 6.6672
Additional loss from day 63 to day 64 T 0.096 0.096 0.096 0.096 0.096 0.096 0.096 0.096 0.096

Shrinkage loss at day 64 To day 92


Initial shrinkage strain at the time of application of load = 6E-05
Shrinkage strain at day 92 = 0.0002
Total shrinkage loss at day: 92 Tonne 9.0277 9.0277 9.0277 9.0277 9.0277 9.0277 9.0277 9.0277 9.0277
Additional loss from day 64 to day 92 T 2.3605 2.3605 2.3605 2.3605 2.3605 2.3605 2.3605 2.3605 2.3605

Shrinkage loss at day 92 To day 36500


Initial shrinkage strain at the time of application of load = 6E-05
Shrinkage strain at day 36500 = 0.0004
Total shrinkage loss at day: 36500 Tonne 28.966 28.966 28.966 28.966 28.966 28.966 28.966 28.966 28.966
Additional loss from day 92 to day 36500 T 19.939 19.939 19.939 19.939 19.939 19.939 19.939 19.939 19.939

EPC Contractor-M/s Krishna Constructions 49


Design ch-109+720
Design of PSC Girder

Immidiate loses after first stage pre-stressing


Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Stages
At day 14 Friction & slip Tonne 58.661 58.374 58.122 55.386 52.574 52.134 45.455 38.789 32.757
Elastic shortening Tonne 16.916 16.916 16.916 16.916 16.916 16.916 16.916 16.916 16.916

Time dependent losses after I stage prestressing :


Relaxation Loss : For Stage-I cable, On account of Stage-I cable prestressing
Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Stages
Relaxation loss from 14 To day 28 Tonne 11.218 11.244 11.267 11.521 11.785 11.826 12.462 13.176 14.03
Relaxation loss from 28 To day 35 Tonne 0.8139 0.8158 0.8174 0.8359 0.855 0.858 0.9042 0.956 1.0179
Relaxation loss from 35 To day 63 Tonne 1.3358 1.3389 1.3416 1.3718 1.4033 1.4082 1.4839 1.5689 1.6706
Relaxation loss from 63 To day 64 Tonne 0.0015 0.0015 0.0015 0.0015 0.0015 0.0015 0.0016 0.0017 0.0018
Relaxation loss from 64 To day 92 Tonne 0.0411 0.0412 0.0413 0.0422 0.0432 0.0433 0.0456 0.0483 0.0514
Relaxation loss from 92 To day 36500 Tonne 26.661 26.722 26.776 27.381 28.008 28.107 29.618 31.314 33.343

Creep Loss :
For Stage-I cable, On account of Stage-I cable prestressing
Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Stages
Creep loss from 14 To day 28 Tonne 12.049 12.045 12.043 14.89 20.1 20.1 19.963 19.714 19.569
Creep loss from 28 To day 35 Tonne 1.52 1.5195 1.5193 1.8784 2.5357 2.5357 2.5185 2.487 2.4688
Creep loss from 35 To day 63 Tonne 3.7346 3.7334 3.7328 4.6151 6.23 6.2301 6.1877 6.1103 6.0656
Creep loss from 63 To day 64 Tonne 0.0984 0.0984 0.0984 0.1217 0.1642 0.1642 0.1631 0.1611 0.1599
Creep loss from 64 To day 92 Tonne 2.2727 2.272 2.2717 2.8086 3.7914 3.7914 3.7656 3.7185 3.6913
Creep loss from 92 To day 36500 Tonne 19.684 19.678 19.675 24.325 32.837 32.837 32.614 32.206 31.97

EPC Contractor-M/s Krishna Constructions 50


Design ch-109+720
Design of PSC Girder

Shrinkage Loss :
For Stage-I cable, On account of Stage-I cable prestressing
Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Stages
Shrinkage loss from 14 To day 28 Tonne 2.4207 2.4207 2.4207 2.4207 2.4207 2.4207 2.4207 2.4207 2.4207
Shrinkage loss from 28 To day 35 Tonne 0.9884 0.9884 0.9884 0.9884 0.9884 0.9884 0.9884 0.9884 0.9884
Shrinkage loss from 35 To day 63 Tonne 3.1621 3.1621 3.1621 3.1621 3.1621 3.1621 3.1621 3.1621 3.1621
Shrinkage loss from 63 To day 64 Tonne 0.096 0.096 0.096 0.096 0.096 0.096 0.096 0.096 0.096
Shrinkage loss from 64 To day 92 Tonne 2.3605 2.3605 2.3605 2.3605 2.3605 2.3605 2.3605 2.3605 2.3605
Shrinkage loss from 92 To day 36500 Tonne 19.939 19.939 19.939 19.939 19.939 19.939 19.939 19.939 19.939

EPC Contractor-M/s Krishna Constructions 51


Design ch-109+720
Design of PSC Girder

Pre-Stress Loss Calculation after Stage II Prestressing :


Stage : 2
At day 28 Action : Prestressing of stage II cables

Description Stage I cables Stage II cables

Total Nos. of strand stressed Nos. : 48 30


Nos. of cable Nos. : 2.52632 1.57895
X-sectional area of one cable mm2 : 1875.49 1875.49
Crosssectional area of cables Ap mm2 : 4738.08 2961.3
UTS of cables Tonne : 881.757 551.098

Modulus of Elasticity of pre-stressing steel Ep : 195000 N/mm2

Section properties
Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Section at 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Properties of Precast Section
Area m2 1.92971 1.92971 1.92971 1.43945 0.94469 0.94469 0.94469 0.94469 0.9447
I gross m4 0.87202 0.87202 0.87202 0.74007 0.60691 0.60691 0.60691 0.60691 0.6069
yb m 1.16766 1.16766 1.16766 1.16004 1.15235 1.15235 1.15235 1.15235 1.1524
Properties of Composite Section
Area m2 2.50251 2.50251 2.50251 2.01225 1.51748 1.51748 1.51748 1.51748 1.5175
I gross m4 1.55604 1.55604 1.55604 1.36551 1.17322 1.17322 1.17322 1.17322 1.1732
yb m 1.45202 1.45202 1.45202 1.53914 1.62707 1.62707 1.62707 1.62707 1.6271

Forces Before Friction & Slip Loss (Total Force)


Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Length m 0.213 0.187 1.742 1.758 0.275 4.175 4.175 4.175
Cable- No.
1 Tonne 0 0 0 0 0 0 0 0 0
2 Tonne 0 0 0 0 0 0 0 0 0
3 Tonne 0 0 0 0 0 0 0 0 0
4 Tonne 210.795 210.795 210.795 210.795 210.795 210.795 210.795 210.795 210.79
5 Tonne 210.795 210.795 210.795 210.795 210.795 210.795 210.795 210.795 210.79

EPC Contractor-M/s Krishna Constructions 52


Design ch-109+720
Design of PSC Girder

Tonne
Total (P2o) Tonne 421.59 421.59 421.59 421.59 421.59 421.59 421.59 421.59 421.59
Avg. P2o Tonne 421.59 421.59 421.59 421.59 421.59 421.59 421.59 421.59

Forces after Friction & Slip Loss : (Horizontal Component)


Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Length m 0.213 0.187 1.742 1.758 0.275 4.175 4.175 4.175
Cable- No.
1 Tonne 0 0 0 0 0 0 0 0 0
2 Tonne 0 0 0 0 0 0 0 0 0
3 Tonne 0 0 0 0 0 0 0 0 0
4 Tonne 187.979 188.068 188.146 189.486 190.918 191.142 194.543 197.944 199.58
5 Tonne 185.855 185.944 186.022 187.608 189.321 189.589 193.657 197.726 198.34
Tonne
Total (F2h) Tonne 373.834 374.012 374.168 377.094 380.239 380.731 388.201 395.67 397.92
Eccen soffit m 1.49272 1.46298 1.43686 1.20552 1.00229 0.97327 0.62454 0.44839 0.4247
Pre-stress loss Tonne 47.7555 47.5778 47.4219 44.4962 41.3509 40.8589 33.3892 25.9196 23.674
Avg. F2h Tonne 373.923 374.09 375.631 378.666 380.485 384.466 391.935 396.79

Prestressing force & their eccentricity from cg. of section of Stage II cables :
Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Section at 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1

Total (F2h) Tonne 373.834 374.012 374.168 377.094 380.239 380.731 388.201 395.67 397.92
eF m -0.3251 -0.2953 -0.2692 -0.0455 0.15006 0.17908 0.52781 0.70396 0.7277
eFc m -0.0407 -0.011 0.01515 0.33363 0.62478 0.6538 1.00253 1.17868 1.2024

eF = Eccentricity of pre-stressing force from cg. of precast section


eFc = Eccentricity of pre-stressing force from cg. of composite section

EPC Contractor-M/s Krishna Constructions 53


Design ch-109+720
Design of PSC Girder

STRESS AT CG. OF CABLES DUE TO EXTERNAL APPLIED FORCES


Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Section at Action m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Load Day
External Permanent Forces : (BM)
SG 28 Non Composite Tm 0.72967 -8.6895 -16.778 -84.646 -142.08 -150.3 -253.22 -314.97 -335.55

Stresses at cg. of stage-I cables :


Eccentricity of pre-stressing force from cg. of composite section of stage I cables
eF m 0.77853 0.78589 0.79234 0.84186 0.8844 0.89157 0.97786 1.02154 1.0274
Load Day
SG 28 Non Composite N/mm2 0.00651 -0.0783 -0.1525 -0.9629 -2.0704 -2.208 -4.0799 -5.3015 -5.6801

Stresses at cg. of stage-II cables :


Eccentricity of pre-stressing force from cg. of composite section of stage II cables
eF m -0.3251 -0.2953 -0.2692 -0.0455 0.15006 0.17908 0.52781 0.70396 0.7277
Load Day
SG 28 Non Composite N/mm2 -0.0027 0.02943 0.0518 0.05202 -0.3513 -0.4435 -2.2022 -3.6534 -4.0231

Time variable parmeters


Satge Day Concrete strength property
bcc(t) fcm (t) Ecm(t)
ShrinkageCreep
strain factor f(t,to) % Mpa Mpa

Casting of concrete at day 0 3.3E-06 0 0 0


Transfer of pre-stress at day stage-I 14 5.7E-05 - 90.1628 45.0814 31990.6
Transfer of pre-stress at day stage -Stage II 28 8.3E-05 0 100 50 33000
Casting of deck -III 35 9.4E-05 0.41011 100 50 33000
Transfer over permanent Brg. - Stage IV 63 0.00013 0.65719 100 50 33000
Placing of SIDL - Stage V 64 0.00013 0.66251 100 50 33000
Open to LL - Stage -VI 92 0.00015 0.77883 100 50 33000
At ∞ 36500 0.00037 1.64458 100 50 33000

EPC Contractor-M/s Krishna Constructions 54


Design ch-109+720
Design of PSC Girder

1) Losses due to Elastic Shortining :


At day 28
A) Elastic shortining of Ist stage cables due to IInd stage cable stressing
loss in pre-stres force = Ep/Ec*sav.*N1*As
N1 = Total Nos. of I stage cable = 2.52632 Nos
As = Area of one cable = 1875.49 mm2

Modulus of Elasticity of concrete Ec = 33000 N/mm2


Modulus of Elasticity of tendons Ep = 195000 N/mm2

Calculating Stress at the centroid of Ist stage cables due to II stage cables
Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Length m 0.213 0.187 1.742 1.758 0.275 4.175 4.175 4.175
Forces Left in Ist stage cables at day 28
F1h" Tonne 514 514.552 515.034 517.48 517.716 518.567 531.628 544.689 556.09
eF m 0.77853 0.78589 0.79234 0.84186 0.8844 0.89157 0.97786 1.02154 1.0274

Stress at the centroid of Ist stage cables due to II stage cables


sc1 Action : Composite N/mm2 0.85233 0.94274 1.02374 2.42462 4.85649 5.03187 7.41066 8.87669 9.1135
Avg. stress N/mm2 0.89754 0.98324 1.72418 3.64056 4.94418 6.22127 8.14367 8.9951

Weight average of concrete stresses at cg. of pre-stressing foce.


sav. = 6.50698 N/mm2
Average loss in pre-stres force = 18.2181 Tonne

B) Elastic shortining of IInd stage cables due to IInd stage cable stressing
At day 28
loss in pre-stres force = 0.5*Ep/Ec*sav.*(N-1)*As
N-1 = Total Nos. of stage II cable - 1 = 1.57895 Nos
As = Area of one cable = 1875.49 mm2

Modulus of Elasticity of concrete Ec = 33000 N/mm2


Modulus of Elasticity of tendons Ep = 195000 N/mm2

EPC Contractor-M/s Krishna Constructions 55


Design ch-109+720
Design of PSC Girder

Calculating Stress at the centroid of IIst stage cables due to II stage cables
Sections c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Length 0.213 0.187 1.742 1.758 0.275 4.175 4.175 4.175
Forces Left in IIst stage cables after friction & slip loss at day 28
F2h Tonne 373.834 374.012 374.168 377.094 380.239 380.731 388.201 395.67 397.92
eF m -0.3251 -0.2953 -0.2692 -0.0455 0.15006 0.17908 0.52781 0.70396 0.7277

Stress at the centroid of IIst stage cables due to II stage cables


sc1 N/mm2 2.39025 2.31224 2.24995 2.63025 4.1661 4.23142 5.89125 7.41919 7.6837
Avg. stress N/mm2 2.35125 2.2811 2.4401 3.39817 4.19876 5.06134 6.65522 7.5515

Weighted average of concrete stresses at cg. of pre-stressing foce.


sav. = 5.55393 N/mm2
Average loss in pre-stres force = 4.8593 Tonne

Pre-stressing force at section after Elastic shortining loss due to II stage cables
At day = 28
Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Length m 0.213 0.187 1.742 1.758 0.275 4.175 4.175 4.175
Forces In I -stage cables
F1h'' T 495.782 496.334 496.816 499.262 499.498 500.349 513.41 526.471 537.88
eF m 0.77853 0.78589 0.79234 0.84186 0.8844 0.89157 0.97786 1.02154 1.0274
F1h'' avg. T 496.058 496.575 498.039 499.38 499.924 506.88 519.94 532.17
Weighted average of pre-stress force I stage cables = 514.389 tonne

Forces In II -stage cables


F2h' Tonne T 368.975 369.153 369.309 372.234 375.38 375.872 383.341 390.811 393.06
eF m m -0.3251 -0.2953 -0.2692 -0.0455 0.15006 0.17908 0.52781 0.70396 0.7277
F2h' avg. T 369.064 369.231 370.772 373.807 375.626 379.607 387.076 391.93
Weighted average of pre-stress force II stage cables = 382.707 tonne

Forces In I + II -stage cables


Fh' Tonne T 864.757 865.486 866.125 871.497 874.878 876.221 896.751 917.282 930.93
eF m m 0.30765 0.32472 0.33971 0.46286 0.56932 0.58594 0.78548 0.88623 0.9008

EPC Contractor-M/s Krishna Constructions 56


Design ch-109+720
Design of PSC Girder

Weighted average of pre-stress force I + II stage cables = 897.096 tonne

Weighted average of pre-stress loss (I+II) = 18.2181 + 4.8593


= 23.0774 Tonne

Claculation of stresses at the stage-I & stage-II cables afeter ES loss due to prestressing of II stage cables.
At day 28
Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Total force in Stage II prestressing after ES loss due to II satge cables.
Fh' Tonne 368.975 369.153 369.309 372.234 375.38 375.872 383.341 390.811 393.06
eF m -0.3251 -0.2953 -0.2692 -0.0455 0.15006 0.17908 0.52781 0.70396 0.7277
eFc m -0.0407 -0.011 0.01515 0.33363 0.62478 0.6538 1.00253 1.17868 1.2024

Stresses at cg. of Stage-I cables.


Stage I cables from cg. of cmposite section m 0.77853 0.78589 0.79234 0.84186 0.8844 0.89157 0.97786 1.02154 1.0274
Due to Prestressing force of stage II N/mm2 0.84125 0.93049 1.01044 2.39338 4.79443 4.96765 7.3179 8.76767 9.0022
Permanent Load stresses N/mm2 0.00651 -0.0783 -0.1525 -0.9629 -2.0704 -2.208 -4.0799 -5.3015 -5.6801

Total stresses N/mm2 0.84777 0.85218 0.85799 1.43049 2.72405 2.75966 3.23801 3.46621 3.3222

Stresses at cg. of Stage-II cables.


Stage II cables from cg. of composite section m -0.3251 -0.2953 -0.2692 -0.0455 0.15006 0.17908 0.52781 0.70396 0.7277
Due to Prestressing force of stage II N/mm2 2.35918 2.2822 2.22073 2.59635 4.11286 4.17742 5.8175 7.32808 7.5899
Permanent Load stresses N/mm2 -0.0027 0.02943 0.0518 0.05202 -0.3513 -0.4435 -2.2022 -3.6534 -4.0231

Total stresses N/mm2 2.35646 2.31163 2.27253 2.64837 3.76157 3.73392 3.61534 3.67472 3.5668

EPC Contractor-M/s Krishna Constructions 57


Design ch-109+720
Design of PSC Girder

CALCULATION OF CREEP LOSS IN STAGE - I CABLES ON ACCOUNT OF ADDITIONAL STRESSES DUE TO SECOND STAGE PRESTRESSING :

DPc+s+r = Ap [ Ep/Ec f(t,to) sc ]


Ap = Area of all prestressing tendons. = 4738.08 mm2
Decs = Free shrinkage strain.
Ep = Modulus of elasticity of prestressing steel. = 195000 Mpa

Creep Loss at different stages:


Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Concrete stress before II stage prestress at day = 28
Prestress force in Stage I cables just before second stgae prestress applied
T 514 514.552 515.034 517.48 517.716 518.567 531.628 544.689 556.09
Eccentricity from cg. of precast section eF m 0.77853 0.78589 0.79234 0.84186 0.8844 0.89157 0.97786 1.02154 1.0274
Concrete stress due to-
Prestress force of stage I Mpa 6.23628 6.31086 6.37696 8.5507 12.1524 12.2813 14.0037 15.1314 15.557
Due to permanent load 0.00651 -0.0783 -0.1525 -0.9629 -2.0704 -2.208 -4.0799 -5.3015 -5.6801

Total stress 6.2428 6.23255 6.2245 7.58782 10.082 10.0733 9.9238 9.82995 9.8773

Total concrete stresses at cg. Stage I cables after stgae II prestress applied (after ES loss taken place)
0.84777 0.85218 0.85799 1.43049 2.72405 2.75966 3.23801 3.46621 3.3222

Net additional steress applied Mpa 0.84125 0.93049 1.01044 2.39338 4.79443 4.96765 7.3179 8.76767 9.0022

Crep loss from day 28 To day 35


Creep coefficent at day 35 = 0.41011
Concrete Modulus of elasticity at the time of loading = 33000 Mpa
Total Creep loss at day: 35 T 0.96593 1.0684 1.16019 2.74808 5.50498 5.70387 8.40244 10.0671 10.336
Additional loss from day 28 to day 35 T 0.96593 1.0684 1.16019 2.74808 5.50498 5.70387 8.40244 10.0671 10.336

Crep loss from day 35 To day 63


Creep coefficent at day 63 = 0.65719
Concrete Modulus of elasticity at the time of loading = 33000 Mpa
Total Creep loss at day: 63 T 1.5479 1.7121 1.8592 4.40379 8.82169 9.14042 13.4649 16.1324 16.564

EPC Contractor-M/s Krishna Constructions 58


Design ch-109+720
Design of PSC Girder

Additional loss from day 35 to day 63 T 0.58197 0.6437 0.69901 1.65571 3.31672 3.43655 5.06242 6.06535 6.2276

Crep loss from day 63 To day 64


Creep coefficent at day 64 = 0.66251
Concrete Modulus of elasticity at the time of loading = 33000 Mpa
Total Creep loss at day: 64 T 1.56042 1.72595 1.87424 4.43941 8.89305 9.21435 13.5738 16.2629 16.698
Additional loss from day 63 to day 64 T 0.01252 0.01385 0.01504 0.03562 0.07136 0.07394 0.10892 0.1305 0.134

Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Crep loss from day 64 To day 92
Creep coefficent at day 92 = 0.77883
Concrete Modulus of elasticity at the time of loading = 33000 Mpa
Total Creep loss at day: 92 T 1.83439 2.02899 2.20332 5.21888 10.4545 10.8322 15.9571 19.1184 19.63
Additional loss from day 64 to day 92 T 0.27398 0.30304 0.32908 0.77947 1.56144 1.61785 2.38328 2.85544 2.9318

Crep loss from day 92 To day 36500


Creep coefficent at day 36500 = 1.64458
Concrete Modulus of elasticity at the time of loading = 33000 Mpa
Total Creep loss at day: 36500 T 3.87352 4.28443 4.65254 11.0202 22.0758 22.8734 33.695 40.3704 41.45
Additional loss from day 92 to day 36500 T 2.03912 2.25544 2.44922 5.80134 11.6213 12.0411 17.738 21.2521 21.821

Immidiate loses in stage I cables due to elastic shortening losses due to second stage pre-stressing
Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Stages
At day 28 Elastic shortening Tonne 18.2181 18.2181 18.2181 18.2181 18.2181 18.2181 18.2181 18.2181 18.218

Time dependent losses in I stage prestressing cables :


Creep Loss :
For Stage-I cable, On account of II Stage cable prestressing
Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Stages

EPC Contractor-M/s Krishna Constructions 59


Design ch-109+720
Design of PSC Girder

Creep loss from 28 To day 35 Tonne 0.96593 1.0684 1.16019 2.74808 5.50498 5.70387 8.40244 10.0671 10.336
Creep loss from 35 To day 63 Tonne 0.58197 0.6437 0.69901 1.65571 3.31672 3.43655 5.06242 6.06535 6.2276
Creep loss from 63 To day 64 Tonne 0.01252 0.01385 0.01504 0.03562 0.07136 0.07394 0.10892 0.1305 0.134
Creep loss from 64 To day 92 Tonne 0.27398 0.30304 0.32908 0.77947 1.56144 1.61785 2.38328 2.85544 2.9318
Creep loss from 92 To day 36500 Tonne 2.03912 2.25544 2.44922 5.80134 11.6213 12.0411 17.738 21.2521 21.821

Time Deepndent losses for stage II cables:


Application of initial pre-stress at = 28 day
Total UTS of cables = 551.098 Tonne
Total time dependent losses due to creep shrinkage & relaxation.

DPc+s+r = Decs Ep + Dspr + Ep/Ec f(t,to) sc


Ap [ 1+ (Ep/Ece) (Ap/Ac) (1 +Ac /Ic *e^2) ]

The denominator is taken as unity for simplicity


Modified formula for time dependent losses
DPc+s+r = Ap [ Decs Ep + Dspr + Ep/Ec f(t,to) sc ]
Ap = Area of all prestressing tendons. = 2961.3 mm2
Decs = Free shrinkage strain.
Ep = Modulus of elasticity of prestressing steel. = 195000 Mpa
Dspr = Variation in stress in the tendons at time t, due to relaxation of the prestressing steel.
Ec = modulus of elasticity of concrete at time t0.
f(t,to) = Creep coefficient at a time t for initial load application at time t0.
sc =
Stress in the concrete adjacent to the tendons due to self-weight, initial prestress and all other quasi-permanent actions where relevant.
Ece = Effective modulus of elasticity of concrete for time t to t0
Ac = Area of the concrete section
Ic = second moment of area of the concrete section
e =
eccentricity of the tendons, i.e. the distance between the centroid of the tendons and the centroid of the concrete section.

EPC Contractor-M/s Krishna Constructions 60


Design ch-109+720
Design of PSC Girder

Relaxation Loss at different stages:


Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Force after ES F2h' T 368.975 369.153 369.309 372.234 375.38 375.872 383.341 390.811 393.06
F2h' / UTS 0.66953 0.66985 0.67013 0.67544 0.68115 0.68204 0.6956 0.70915 0.7132
At 1000 Hrs % loss 2.11909 2.12312 2.12666 2.19302 2.26436 2.27552 2.44495 2.683 2.7645
Final at 500000 Hrs. % loss 6.35727 6.36936 6.37998 6.57906 6.79308 6.82656 7.33484 8.04899 8.2935

Relaxation loss at day 28 To day 35


% loss at day 35 Days % loss 1.62661 1.62971 1.63242 1.68336 1.73812 1.74669 1.87674 2.05947 2.122
Dspr Mpa 20.2675 20.3158 20.3582 21.1598 22.0328 22.1704 24.2945 27.1794 28.166
Total Relaxation loss at day 35 Tonne 6.0018 6.01611 6.02868 6.26605 6.52456 6.56531 7.19432 8.04863 8.3408
Additional loss from day 28 to day 35 Tonne 6.0018 6.01611 6.02868 6.26605 6.52456 6.56531 7.19432 8.04863 8.3408

Relaxation loss at day 35 To day 63


% loss at day 63 Days % loss 2.05128 2.05518 2.05861 2.12284 2.1919 2.2027 2.36671 2.59714 2.676
Dspr Mpa 25.5588 25.6197 25.6732 26.6841 27.7849 27.9585 30.6371 34.2752 35.519
Total Relaxation loss at day 63 Tonne 7.56871 7.58676 7.60261 7.90195 8.22795 8.27934 9.07257 10.1499 10.518
Additional loss from day 35 to day 63 Tonne 1.56691 1.57065 1.57393 1.6359 1.70339 1.71403 1.87825 2.10128 2.1776

Relaxation loss at day 63 To day 64


% loss at day 64 Days % loss 2.06145 2.06537 2.06881 2.13337 2.20277 2.21363 2.37844 2.61002 2.6893
Dspr Mpa 25.6855 25.7467 25.8005 26.8164 27.9227 28.0971 30.789 34.4452 35.695
Total Relaxation loss at day 64 Tonne 7.60625 7.62438 7.64031 7.94113 8.26875 8.3204 9.11756 10.2002 10.57
Additional loss from day 63 to day 64 Tonne 0.03753 0.03762 0.0377 0.03918 0.0408 0.04105 0.04499 0.05033 0.0522

Relaxation loss at day 64 To day 92


% loss at day 92 Days % loss 2.12429 2.12833 2.13188 2.1984 2.26992 2.2811 2.45094 2.68958 2.7713
Dspr Mpa 26.4684 26.5315 26.587 27.6338 28.7739 28.9536 31.7276 35.4951 36.783
Total Relaxation loss at day 92 Tonne 7.8381 7.85679 7.8732 8.1832 8.5208 8.57402 9.39548 10.5112 10.893
Additional loss from day 64 to day 92 Tonne 0.23186 0.23241 0.23289 0.24206 0.25205 0.25362 0.27792 0.31093 0.3222

Relaxation loss at day 92 To day 36500

EPC Contractor-M/s Krishna Constructions 61


Design ch-109+720
Design of PSC Girder

% loss at day 36500 Days % loss 6.35727 6.36936 6.37998 6.57906 6.79308 6.82656 7.33484 8.04899 8.2935
Dspr Mpa 79.211 79.3999 79.5658 82.6985 86.1103 86.6481 94.9498 106.225 110.08
Total Relaxation loss at day 36500 Tonne 23.4568 23.5127 23.5618 24.4895 25.4999 25.6591 28.1175 31.4563 32.598
Additional loss from day 92 to day 36500 Tonne 15.6187 15.6559 15.6886 16.3063 16.979 17.0851 18.722 20.9452 21.705

Creep Loss at different stages:


Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Load applied at an age = 28 Day
Initial concrete stress sc Mpa 2.35646 2.31163 2.27253 2.64837 3.76157 3.73392 3.61534 3.67472 3.5668
Crep loss at day 28 To day 35
Creep coefficent at day 35 = 0.41011
Concrete Modulus of elasticity at the time of loading = 33000 Mpa
Total Creep loss at day: 35 T 1.69106 1.65889 1.63083 1.90054 2.69941 2.67956 2.59447 2.63708 2.5596
Additional loss from day 28 to day 35 T 1.69106 1.65889 1.63083 1.90054 2.69941 2.67956 2.59447 2.63708 2.5596

EPC Contractor-M/s Krishna Constructions 62


Design ch-109+720
Design of PSC Girder

Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Crep loss at day 35 To day 63
Creep coefficent at day 63 = 0.65719
Concrete Modulus of elasticity at the time of loading = 33000 Mpa
Total Creep loss at day: 63 T 2.70991 2.65836 2.61339 3.04561 4.32578 4.29398 4.15762 4.22591 4.1018
Additional loss from day 35 to day 63 T 1.01885 0.99947 0.98257 1.14507 1.62638 1.61442 1.56315 1.58883 1.5422

Crep loss at day 63 To day 64


Creep coefficent at day 64 = 0.66251
Concrete Modulus of elasticity at the time of loading = 33000 Mpa
Total Creep loss at day: 64 T 2.73184 2.67986 2.63453 3.07024 4.36078 4.32871 4.19125 4.26009 4.135
Additional loss from day 63 to day 64 T 0.02192 0.0215 0.02114 0.02464 0.03499 0.03473 0.03363 0.03418 0.0332

Crep loss at day 64 To day 92


Creep coefficent at day 92 = 0.77883
Concrete Modulus of elasticity at the time of loading = 33000 Mpa
Total Creep loss at day: 92 T 3.21149 3.15039 3.09711 3.60931 5.12644 5.08875 4.92715 5.00808 4.861
Additional loss from day 64 to day 92 T 0.47965 0.47053 0.46257 0.53907 0.76566 0.76003 0.7359 0.74799 0.726

Crep loss at day 92 To day 36500


Creep coefficent at day 36500 = 1.64458
Concrete Modulus of elasticity at the time of loading = 33000 Mpa
Total Creep loss at day: 36500 T 6.7814 6.65238 6.53987 7.62145 10.825 10.7454 10.4042 10.5751 10.264
Additional loss from day 64 to day 36500 T 3.56991 3.50199 3.44276 4.01214 5.69858 5.65668 5.47705 5.56701 5.4035

Shrinkage Loss at different stages:


Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1

EPC Contractor-M/s Krishna Constructions 63


Design ch-109+720
Design of PSC Girder

Stages
Load applied at an age 28

Shrinkage loss at day 28 To day 35


Initial shrinkage strain at the time of application of load = 8.3E-05
Shrinkage strain at day 35 = 9.4E-05
Total shrinkage loss at day: 35 Tonne 0.61774 0.61774 0.61774 0.61774 0.61774 0.61774 0.61774 0.61774 0.6177
Additional loss from day 28 to day 35 Tonne 0.61774 0.61774 0.61774 0.61774 0.61774 0.61774 0.61774 0.61774 0.6177

Shrinkage loss at day 35 To day 63


Initial shrinkage strain at the time of application of load = 8.3E-05
Shrinkage strain at day 63 = 0.00013
Total shrinkage loss at day: 63 Tonne 2.59408 2.59408 2.59408 2.59408 2.59408 2.59408 2.59408 2.59408 2.5941
Additional loss from day 35 to day 63 Tonne 1.97634 1.97634 1.97634 1.97634 1.97634 1.97634 1.97634 1.97634 1.9763

Shrinkage loss at day 63 To day 64


Initial shrinkage strain at the time of application of load = 8.3E-05
Shrinkage strain at day 64 = 0.00013
Total shrinkage loss at day: 64 Tonne 2.65406 2.65406 2.65406 2.65406 2.65406 2.65406 2.65406 2.65406 2.6541
Additional loss from day 63 to day 64 Tonne 0.05998 0.05998 0.05998 0.05998 0.05998 0.05998 0.05998 0.05998 0.06

Shrinkage loss at day 64 To day 92


Initial shrinkage strain at the time of application of load = 8.3E-05
Shrinkage strain at day 92 = 0.00015
Total shrinkage loss at day: 92 Tonne 4.12935 4.12935 4.12935 4.12935 4.12935 4.12935 4.12935 4.12935 4.1293
Additional loss from day 64 to day 92 Tonne 1.47528 1.47528 1.47528 1.47528 1.47528 1.47528 1.47528 1.47528 1.4753

Shrinkage loss at day 92 To day 36500


Initial shrinkage strain at the time of application of load = 8.3E-05
Shrinkage strain at day 36500 = 0.00037
Total shrinkage loss at day: 36500 Tonne 16.5909 16.5909 16.5909 16.5909 16.5909 16.5909 16.5909 16.5909 16.591
Additional loss from day 64 to day 36500 Tonne 12.4616 12.4616 12.4616 12.4616 12.4616 12.4616 12.4616 12.4616 12.462

Immidiate loses after second stage pre-stressing in II stage cables


Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Stages

EPC Contractor-M/s Krishna Constructions 64


Design ch-109+720
Design of PSC Girder

At day 28 Friction & slip Tonne 47.7555 47.5778 47.4219 44.4962 41.3509 40.8589 33.3892 25.9196 23.674
Elastic shortening Tonne 4.8593 4.8593 4.8593 4.8593 4.8593 4.8593 4.8593 4.8593 4.8593

Time dependent losses II stage cables :


Relaxation Loss : For Stage-II cable, On account of Stage-II cable prestressing
Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Stages
Relaxation loss from 28 To day 35 Tonne 6.0018 6.01611 6.02868 6.26605 6.52456 6.56531 7.19432 8.04863 8.3408
Relaxation loss from 35 To day 63 Tonne 1.56691 1.57065 1.57393 1.6359 1.70339 1.71403 1.87825 2.10128 2.1776
Relaxation loss from 63 To day 64 Tonne 0.03753 0.03762 0.0377 0.03918 0.0408 0.04105 0.04499 0.05033 0.0522
Relaxation loss from 64 To day 92 Tonne 0.23186 0.23241 0.23289 0.24206 0.25205 0.25362 0.27792 0.31093 0.3222
Relaxation loss from 92 To day 36500 Tonne 15.6187 15.6559 15.6886 16.3063 16.979 17.0851 18.722 20.9452 21.705

Creep Loss : For Stage-II cable, On account of Stage-II cable prestressing


Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Stages
Creep loss from 28 To day 35 Tonne 1.69106 1.65889 1.63083 1.90054 2.69941 2.67956 2.59447 2.63708 2.5596
Creep loss from 35 To day 63 Tonne 1.01885 0.99947 0.98257 1.14507 1.62638 1.61442 1.56315 1.58883 1.5422
Creep loss from 63 To day 64 Tonne 0.02192 0.0215 0.02114 0.02464 0.03499 0.03473 0.03363 0.03418 0.0332
Creep loss from 64 To day 92 Tonne 0.47965 0.47053 0.46257 0.53907 0.76566 0.76003 0.7359 0.74799 0.726
Creep loss from 92 To day 36500 Tonne 3.56991 3.50199 3.44276 4.01214 5.69858 5.65668 5.47705 5.56701 5.4035

Shrinkage Loss : For Stage-II cable, On account of Stage-II cable prestressing


Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Stages
Shrinkage loss from 28 To day 35 Tonne 0.61774 0.61774 0.61774 0.61774 0.61774 0.61774 0.61774 0.61774 0.6177
Shrinkage loss from 35 To day 63 Tonne 1.97634 1.97634 1.97634 1.97634 1.97634 1.97634 1.97634 1.97634 1.9763
Shrinkage loss from 63 To day 64 Tonne 0.05998 0.05998 0.05998 0.05998 0.05998 0.05998 0.05998 0.05998 0.06
Shrinkage loss from 64 To day 92 Tonne 1.47528 1.47528 1.47528 1.47528 1.47528 1.47528 1.47528 1.47528 1.4753
Shrinkage loss from 92 To day 36500 Tonne 12.4616 12.4616 12.4616 12.4616 12.4616 12.4616 12.4616 12.4616 12.462

EPC Contractor-M/s Krishna Constructions 65


Design ch-109+720
Design of PSC Girder

CALCULATION OF STRESS GAIN ON ACCOUNT OF DECK SLAB CASTING :


Stage : 3
At day 35 Action : Casting of deck

Section properties (Precast Section Only)


Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Section at 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Properties of Precast Section
Area m2 1.92971 1.92971 1.92971 1.43945 0.94469 0.94469 0.94469 0.94469 0.9447
I gross m4 0.87202 0.87202 0.87202 0.74007 0.60691 0.60691 0.60691 0.60691 0.6069
yb m 1.16766 1.16766 1.16766 1.16004 1.15235 1.15235 1.15235 1.15235 1.1524

Prestressing force & their eccentricity from cg. of section


Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Section at 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
For stage -I cables
eF m 0.77853 0.78589 0.79234 0.84186 0.8844 0.89157 0.97786 1.02154 1.0274
For stage -II cables
eF m -0.3251 -0.2953 -0.2692 -0.0455 0.15006 0.17908 0.52781 0.70396 0.7277
eF = Eccentricity of pre-stressing force from cg. of precast section
eFc = Eccentricity of pre-stressing force from cg. of composite section

STRESS AT CG. OF CABLES DUE TO EXTERNAL APPLIED FORCES


Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Section at Action m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Load Day
External Permanent Forces : (BM)
Deck 35 Non Composite Tm 0.12939 -7.3472 -12.252 -56.169 -97.493 -102.3 -184.62 -235.67 -252.24

Stresses at cg. of stage-I cables :


Eccentricity of pre-stressing force from cg. of precast section of stage I cables
eF m 0.77853 0.78589 0.79234 0.84186 0.8844 0.89157 0.97786 1.02154 1.0274
Load Day
Deck 35 Non Composite N/mm2 0.00116 -0.0662 -0.1113 -0.639 -1.4207 -1.5028 -2.9747 -3.9667 -4.2698

EPC Contractor-M/s Krishna Constructions 66


Design ch-109+720
Design of PSC Girder

Stresses at cg. of stage-II cables :


Eccentricity of pre-stressing force from cg. Of precast section of stage II cables
eF m -0.3251 -0.2953 -0.2692 -0.0455 0.15006 0.17908 0.52781 0.70396 0.7277
Load Day
Deck 35 Non Composite N/mm2 -0.0005 0.02488 0.03783 0.03452 -0.2411 -0.3019 -1.6056 -2.7336 -3.0243

CALCULATION OF CREEP LOSS IN STAGE - I CABLES ON ACCOUNT OF ADDITIONAL STRESSES DUE TO CASTING OF DECK SLAB :
DPc+s+r = Ap [ Ep/Ec f(t,to) sc ]
Ap = Area of all prestressing tendons. = 4738.08 mm2
Decs = Free shrinkage strain.
Ep = Modulus of elasticity of prestressing steel. = 195000 Mpa

Time variable parmeters


Satge Day Concrete strength property
bcc(t) fcm (t) Ecm(t)
ShrinkageCreep
strain factor f(t,to) % Mpa Mpa

Casting of concrete at day 0 3.3E-06 0 0 0


Transfer of pre-stress at day stage-I 14 5.7E-05 - 90.1628 45.0814 31990.6
Transfer of pre-stress at day stage -Stage II 28 8.3E-05 - 100 50 33000
Casting of deck -III 35 9.4E-05 0 100 50 33000
Transfer over permanent Brg. - Stage IV 63 0.00013 0.5907 100 50 33000
Placing of SIDL - Stage V 64 0.00013 0.59672 100 50 33000
Open to LL - Stage -VI 92 0.00015 0.72287 100 50 33000
At ∞ 36500 0.00037 1.57616 100 50 33000

Creep Loss at different stages:


Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Casting of Deck at day = 35
Net additional steress applied Mpa 0.00116 -0.0662 -0.1113 -0.639 -1.4207 -1.5028 -2.9747 -3.9667 -4.2698

Crep loss at day 35 To day 63


Creep coefficent at day 63 = 0.5907
Concrete Modulus of elasticity at the time of loading = 33000 Mpa
Creep loss T 0.00191 -0.1095 -0.1841 -1.0567 -2.3496 -2.4854 -4.9196 -6.5604 -7.0616
Additional loss from day 35 to day 63 T 0.00191 -0.1095 -0.1841 -1.0567 -2.3496 -2.4854 -4.9196 -6.5604 -7.0616

EPC Contractor-M/s Krishna Constructions 67


Design ch-109+720
Design of PSC Girder

Crep loss at day 63 To day 64


Creep coefficent at day 64 = 0.59672
Concrete Modulus of elasticity at the time of loading = 33000 Mpa
Creep loss T 0.00193 -0.1106 -0.186 -1.0675 -2.3735 -2.5107 -4.9697 -6.6271 -7.1335
Additional loss from day 63 to day 64 T 1.9E-05 -0.0011 -0.0019 -0.0108 -0.0239 -0.0253 -0.0501 -0.0668 -0.0719

Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Crep loss at day 64 To day 92
Creep coefficent at day 92 = 0.72287
Concrete Modulus of elasticity at the time of loading = 33000 Mpa
Creep loss T 0.00234 -0.134 -0.2253 -1.2932 -2.8753 -3.0415 -6.0203 -8.0281 -8.6415
Additional loss from day 64 to day 92 T 0.00041 -0.0234 -0.0393 -0.2257 -0.5018 -0.5308 -1.0506 -1.401 -1.508

Crep loss at day 92 To day 36500


Creep coefficent at day 36500 = 1.57616
Concrete Modulus of elasticity at the time of loading = 33000 Mpa
Creep loss T 0.0051 -0.2922 -0.4913 -2.8196 -6.2694 -6.6318 -13.127 -17.505 -18.842
Additional loss from day 92 to day 36500 T 0.00276 -0.1582 -0.266 -1.5265 -3.3941 -3.5903 -7.1066 -9.4767 -10.201

Additional creep loss in stage I cables on account of casting of deck slab :


Creep Loss :
For Stage-I cable, On account of Casting of deck slab
Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Stages
Creep loss from 35 To day 63 Tonne 0.00191 -0.1095 -0.1841 -1.0567 -2.3496 -2.4854 -4.9196 -6.5604 -7.0616
Creep loss from 63 To day 64 Tonne 1.9E-05 -0.0011 -0.0019 -0.0108 -0.0239 -0.0253 -0.0501 -0.0668 -0.0719
Creep loss from 64 To day 92 Tonne 0.00041 -0.0234 -0.0393 -0.2257 -0.5018 -0.5308 -1.0506 -1.401 -1.508
Creep loss from 92 To day 36500 Tonne 0.00276 -0.1582 -0.266 -1.5265 -3.3941 -3.5903 -7.1066 -9.4767 -10.201

EPC Contractor-M/s Krishna Constructions 68


Design ch-109+720
Design of PSC Girder

CALCULATION OF CREEP LOSS IN STAGE - II CABLES ON ACCOUNT OF ADDITIONAL STRESSES DUE TO CASTING OF DECK SLAB :
DPc+s+r = Ap [ Ep/Ec f(t,to) sc ]
Ap = Area of all prestressing tendons. = 2961.3 mm2
Decs = Free shrinkage strain.
Ep = Modulus of elasticity of prestressing steel. = 195000 Mpa

Creep Loss at different stages:


Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Casting of Deck at day = 35
Net additional steress applied Mpa -0.0005 0.02488 0.03783 0.03452 -0.2411 -0.3019 -1.6056 -2.7336 -3.0243

Crep loss at day 35 To day 63


Creep coefficent at day 63 = 0.5907
Concrete Modulus of elasticity at the time of loading = 33000 Mpa
Creep loss T -0.0005 0.02572 0.0391 0.03568 -0.2492 -0.312 -1.6596 -2.8256 -3.126
Additional loss from day 35 to day 63 T -0.0005 0.02572 0.0391 0.03568 -0.2492 -0.312 -1.6596 -2.8256 -3.126

Crep loss at day 63 To day 64


Creep coefficent at day 64 = 0.59672
Concrete Modulus of elasticity at the time of loading = 33000 Mpa
Creep loss T -0.0005 0.02598 0.0395 0.03604 -0.2517 -0.3152 -1.6765 -2.8543 -3.1579
Additional loss from day 63 to day 64 T -5E-06 0.00026 0.0004 0.00036 -0.0025 -0.0032 -0.0169 -0.0288 -0.0318

Crep loss at day 64 To day 92


Creep coefficent at day 92 = 0.72287
Concrete Modulus of elasticity at the time of loading = 33000 Mpa
Creep loss T -0.0006 0.03147 0.04785 0.04366 -0.3049 -0.3818 -2.031 -3.4577 -3.8254
Additional loss from day 64 to day 92 T -0.0001 0.00549 0.00835 0.00762 -0.0532 -0.0666 -0.3544 -0.6034 -0.6676

Crep loss at day 92 To day 36500


Creep coefficent at day 36500 = 1.57616
Concrete Modulus of elasticity at the time of loading = 33000 Mpa
Creep loss T -0.0013 0.06863 0.10432 0.0952 -0.6648 -0.8326 -4.4284 -7.5393 -8.3411
Additional loss from day 92 to day 36500 T -0.0007 0.03715 0.05648 0.05154 -0.3599 -0.4507 -2.3974 -4.0816 -4.5157

EPC Contractor-M/s Krishna Constructions 69


Design ch-109+720
Design of PSC Girder

Additional creep loss in stage I cables on account of casting of deck slab :


Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Stages
Creep loss from 35 To day 63 Tonne -0.0005 0.02572 0.0391 0.03568 -0.2492 -0.312 -1.6596 -2.8256 -3.126
Creep loss from 63 To day 64 Tonne -5E-06 0.00026 0.0004 0.00036 -0.0025 -0.0032 -0.0169 -0.0288 -0.0318
Creep loss from 64 To day 92 Tonne -0.0001 0.00549 0.00835 0.00762 -0.0532 -0.0666 -0.3544 -0.6034 -0.6676
Creep loss from 92 To day 36500 Tonne -0.0007 0.03715 0.05648 0.05154 -0.3599 -0.4507 -2.3974 -4.0816 -4.5157

EPC Contractor-M/s Krishna Constructions 70


Design ch-109+720
Design of PSC Girder

CALCULATION OF STRESS GAIN ON ACCOUNT OF TRANSFER SUPER-STRUCTURE AT TEMPORARY BEARINGS. :


Stage : 4
At day 63 Action : Transfer to permanent bearings.

Section properties (Composite Section)


Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Section at 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Properties of Composite Section
Area m2 2.50251 2.50251 2.50251 2.01225 1.51748 1.51748 1.51748 1.51748 1.51748
I gross m4 1.55604 1.55604 1.55604 1.36551 1.17322 1.17322 1.17322 1.17322 1.17322
yb m 1.45202 1.45202 1.45202 1.53914 1.62707 1.62707 1.62707 1.62707 1.62707

Prestressing force & their eccentricity from cg. of section


Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Section at m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
For stage -I cables
eF m 1.06289 1.07025 1.0767 1.22097 1.35912 1.36629 1.45258 1.49626 1.50207
For stage -II cables
eF m -0.0407 -0.011 0.01515 0.33363 0.62478 0.6538 1.00253 1.17868 1.20238
eF = Eccentricity of pre-stressing force from cg. of precast section
eFc = Eccentricity of pre-stressing force from cg. of composite section

STRESS AT CG. OF CABLES DUE TO EXTERNAL APPLIED FORCES


Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Section at Action m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Load Day
External Permanent Forces : (BM)
Brg. Transfer 63 Composite Tm 0 0 0 0 0 0 0 0 0

Stresses at cg. of stage-I cables :


Eccentricity of pre-stressing force from cg. of precast section of stage I cables
eF m 1.06289 1.07025 1.0767 1.22097 1.35912 1.36629 1.45258 1.49626 1.50207
Load Day
Brg. Transfer 63 Composite N/mm2 0 0 0 0 0 0 0 0 0

EPC Contractor-M/s Krishna Constructions 71


Design ch-109+720
Design of PSC Girder

Stresses at cg. of stage-II cables :


Eccentricity of pre-stressing force from cg. Of precast section of stage II cables
eF m -0.0407 -0.011 0.01515 0.33363 0.62478 0.6538 1.00253 1.17868 1.20238
Load Day
Brg. Transfer 63 Composite N/mm2 0 0 0 0 0 0 0 0 0

Time variable parmeters


Satge Day Concrete strength property
bcc(t) fcm (t) Ecm(t)
ShrinkageCreep
strain factor f(t,to) % Mpa Mpa

Casting of concrete at day 0 3.3E-06 0 0 0


Transfer of pre-stress at day stage-I 14 5.7E-05 - 90.1628 45.0814 31990.6
Transfer of pre-stress at day stage -Stage II 28 8.3E-05 - 100 50 33000
Casting of deck -III 35 9.4E-05 - 100 50 33000
Transfer over permanent Brg. - Stage IV 63 0.00013 0 100 50 33000
Placing of SIDL - Stage V 64 0.00013 0.19642 100 50 33000
Open to LL - Stage -VI 92 0.00015 0.53331 100 50 33000
At ∞ 36500 0.00037 1.40866 100 50 33000

CALCULATION OF CREEP LOSS IN STAGE - I CABLES ON ACCOUNT OF ADDITIONAL STRESSES DUE TO TRANSFER OF SUPER-STRUCTURE AT PERMANENT BEARINGS.:
DPc+s+r = Ap [ Ep/Ec f(t,to) sc ]
Ap = Area of all prestressing tendons. = 4738.08 mm2
Decs = Free shrinkage strain.
Ep = Modulus of elasticity of prestressing steel. = 195000 Mpa

Creep Loss at different stages:


Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Casting of Deck at day = 63
Net additional steress applied Mpa 0 0 0 0 0 0 0 0 0

Crep loss at day 63 To day 64


Creep coefficent at day 64 = 0.19642

EPC Contractor-M/s Krishna Constructions 72


Design ch-109+720
Design of PSC Girder

Concrete Modulus of elasticity at the time of loading = 33000 Mpa


Total Creep loss at day: 64 T 0 0 0 0 0 0 0 0 0
Additional loss from day 63 to day 64 T 0 0 0 0 0 0 0 0 0

Crep loss at day 64 To day 92


Creep coefficent at day 92 = 0.53331
Concrete Modulus of elasticity at the time of loading = 33000 Mpa
Total Creep loss at day: 92 T 0 0 0 0 0 0 0 0 0
Additional loss from day 64 to day 92 T 0 0 0 0 0 0 0 0 0

Crep loss at day 92 To day 36500


Creep coefficent at day 36500 = 1.40866
Concrete Modulus of elasticity at the time of loading = 33000 Mpa
Total Creep loss at day: 36500 T 0 0 0 0 0 0 0 0 0
Additional loss from day 92 to day 36500 T 0 0 0 0 0 0 0 0 0

Additional creep loss in stage I cables on account of Transfer of super-structure at permanent bearings. :
Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Stages
Creep loss from 63 To day 64 Tonne 0 0 0 0 0 0 0 0 0
Creep loss from 64 To day 92 Tonne 0 0 0 0 0 0 0 0 0
Creep loss from 92 To day 36500 Tonne 0 0 0 0 0 0 0 0 0

CALCULATION OF CREEP LOSS IN STAGE - II CABLES ON ACCOUNT OF ADDITIONAL STRESSES DUE TO TRANSFER OF SUPER-STRUCTURE AT PERMANENT BEARINGS.:
DPc+s+r = Ap [ Ep/Ec f(t,to) sc ]
Ap = Area of all prestressing tendons. = 2961.3 mm2
Decs = Free shrinkage strain.
Ep = Modulus of elasticity of prestressing steel. = 195000 Mpa

Creep Loss at different stages:


Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Casting of Deck at day = 63
Net additional steress applied Mpa 0 0 0 0 0 0 0 0 0

EPC Contractor-M/s Krishna Constructions 73


Design ch-109+720
Design of PSC Girder

Crep loss at day 63 To day 64


Creep coefficent at day 64 = 0.19642
Concrete Modulus of elasticity at the time of loading = 33000 Mpa
Total Creep loss at day: 64 T 0 0 0 0 0 0 0 0 0
Additional loss from day 63 to day 64 T 0 0 0 0 0 0 0 0 0

Crep loss at day 64 To day 92


Creep coefficent at day 92 = 0.53331
Concrete Modulus of elasticity at the time of loading = 33000 Mpa
Total Creep loss at day: 92 T 0 0 0 0 0 0 0 0 0
Additional loss from day 64 to day 92 T 0 0 0 0 0 0 0 0 0

Crep loss at day 92 To day 36500


Creep coefficent at day 36500 = 1.40866
Concrete Modulus of elasticity at the time of loading = 33000 Mpa
Creep loss T 0 0 0 0 0 0 0 0 0
Additional loss from day 92 to day 36500 T 0 0 0 0 0 0 0 0 0

Additional creep loss in stage II cables on account of Transfer of super-structure at permanent bearings. :
Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Stages
Creep loss from 63 To day 64 Tonne 0 0 0 0 0 0 0 0 0
Creep loss from 64 To day 92 Tonne 0 0 0 0 0 0 0 0 0
Creep loss from 92 To day 36500 Tonne 0 0 0 0 0 0 0 0 0

EPC Contractor-M/s Krishna Constructions 74


Design ch-109+720
Design of PSC Girder

CALCULATION OF STRESS GAIN ON ACCOUNT OF PLACING OF SIDL :


Stage : 5
At day 64 Action : PLACING OF SIDL

Section properties (Composite Section)


Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Section at m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Properties of Composite Section
Area m2 2.50251 2.50251 2.50251 2.01225 1.51748 1.51748 1.51748 1.51748 1.51748
I gross m4 1.55604 1.55604 1.55604 1.36551 1.17322 1.17322 1.17322 1.17322 1.17322
yb m 1.45202 1.45202 1.45202 1.53914 1.62707 1.62707 1.62707 1.62707 1.62707

Prestressing force & their eccentricity from cg. of section


Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Section at m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
For stage -I cables
eF m 1.06289 1.07025 1.0767 1.22097 1.35912 1.36629 1.45258 1.49626 1.50207
For stage -II cables
eF m -0.0407 -0.011 0.01515 0.33363 0.62478 0.6538 1.00253 1.17868 1.20238

eF = Eccentricity of pre-stressing force from cg. of precast section


eFc = Eccentricity of pre-stressing force from cg. of composite section

STRESS AT CG. OF CABLES DUE TO EXTERNAL APPLIED FORCES


Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Section at Action m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Load Day
External Permanent Forces : (BM)
SIDL 64 Composite Tm 0 -1.672 -3.079 -15.56 -27.248 -28.893 -49.39 -61.68 -65.678

Stresses at cg. of stage-I cables :


Eccentricity of pre-stressing force from cg. of precast section of stage I cables
eF m 1.06289 1.07025 1.0767 1.22097 1.35912 1.36629 1.45258 1.49626 1.50207
Load Day
SIDL 64 Composite N/mm2 0 -0.0115 -0.0213 -0.1391 -0.3157 -0.3365 -0.6115 -0.7866 -0.8409

EPC Contractor-M/s Krishna Constructions 75


Design ch-109+720
Design of PSC Girder

Stresses at cg. of stage-II cables :


Eccentricity of pre-stressing force from cg. Of precast section of stage II cables
eF m -0.0407 -0.011 0.01515 0.33363 0.62478 0.6538 1.00253 1.17868 1.20238
Load Day
SIDL 64 Composite N/mm2 0 0.00012 -0.0003 -0.038 -0.1451 -0.161 -0.422 -0.6197 -0.6731

Time variable parmeters


Satge Day Concrete strength property
bcc(t) fcm (t) Ecm(t)
ShrinkageCreep
strain factor f(t,to) % Mpa Mpa

Casting of concrete at day 0 3.3E-06 0 0 0


Transfer of pre-stress at day stage-I 14 5.7E-05 - 90.1628 45.0814 31990.6
Transfer of pre-stress at day stage -Stage II 28 8.3E-05 - 100 50 33000
Casting of deck -III 35 9.4E-05 - 100 50 33000
Transfer over permanent Brg. - Stage IV 63 0.00013 - 100 50 33000
Placing of SIDL - Stage V 64 0.00013 0 100 50 33000
Open to LL - Stage -VI 92 0.00015 0.52634 100 50 33000
At ∞ 36500 0.00037 1.40441 100 50 33000

CALCULATION OF CREEP LOSS IN STAGE - I CABLES ON ACCOUNT OF ADDITIONAL STRESSES DUE TO PLACING OF SIDL.:
DPc+s+r = Ap [ Ep/Ec f(t,to) sc ]
Ap = Area of all prestressing tendons. = 4738.08 mm2
Decs = Free shrinkage strain.
Ep = Modulus of elasticity of prestressing steel. = 195000 Mpa

Creep Loss at different stages:


Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Casting of Deck at day = 64
Net additional steress applied Mpa 0 -0.0115 -0.0213 -0.1391 -0.3157 -0.3365 -0.6115 -0.7866 -0.8409

Crep loss at day 64 To days 92


Creep coefficent at day 92 = 0.52634

EPC Contractor-M/s Krishna Constructions 76


Design ch-109+720
Design of PSC Girder

Concrete Modulus of elasticity at the time of loading = 33000 Mpa


Total Creep loss at day: 92 T 0 -0.0169 -0.0314 -0.205 -0.4652 -0.4958 -0.9011 -1.1592 -1.2391
Additional loss from day 64 to day 92 T 0 -0.0169 -0.0314 -0.205 -0.4652 -0.4958 -0.9011 -1.1592 -1.2391

Crep loss at day 92 To days 36500


Creep coefficent at day 36500 = 1.40441
Concrete Modulus of elasticity at the time of loading = 33000 Mpa
Total Creep loss at day: 36500 T 0 -0.0452 -0.0838 -0.5471 -1.2412 -1.323 -2.4045 -3.0931 -3.3063
Additional loss from day 92 to day 36500 T 0 -0.0283 -0.0524 -0.342 -0.776 -0.8272 -1.5033 -1.9338 -2.0672

Additional creep loss in stage I cables on account of Placing of SIDL. :


Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Stages
Creep loss from 64 To day 92 Tonne 0 -0.0169 -0.0314 -0.205 -0.4652 -0.4958 -0.9011 -1.1592 -1.2391
Creep loss from 92 To day 36500 Tonne 0 -0.0283 -0.0524 -0.342 -0.776 -0.8272 -1.5033 -1.9338 -2.0672

CALCULATION OF CREEP LOSS IN STAGE - II CABLES ON ACCOUNT OF ADDITIONAL STRESSES DUE TO PLACING OF SIDL.:
DPc+s+r = Ap [ Ep/Ec f(t,to) sc ]
Ap = Area of all prestressing tendons. = 2961.3 mm2
Decs = Free shrinkage strain.
Ep = Modulus of elasticity of prestressing steel. = 195000 Mpa

Creep Loss at different stages:


Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1

Casting of Deck at day = 64


Net additional steress applied Mpa 0 0.00012 -0.0003 -0.038 -0.1451 -0.161 -0.422 -0.6197 -0.6731

Crep loss at day 64 To days 92


Creep coefficent at day = 0.52634
Concrete Modulus of elasticity at the time of loading = 33000 Mpa
Total Creep loss at day: 92 T 0 0.00011 -0.0003 -0.035 -0.1336 -0.1483 -0.3887 -0.5707 -0.6199
Additional loss from day 64 to day 92 T 0 0.00011 -0.0003 -0.035 -0.1336 -0.1483 -0.3887 -0.5707 -0.6199

EPC Contractor-M/s Krishna Constructions 77


Design ch-109+720
Design of PSC Girder

Crep loss at day 92 To days 36500


Creep coefficent at day = 1.40441
Concrete Modulus of elasticity at the time of loading = 33000 Mpa
Total Creep loss at day: 36500 T 0 0.00029 -0.0007 -0.0934 -0.3566 -0.3957 -1.0372 -1.5229 -1.6542
Additional loss from day 92 to day 36500 T 0 0.00018 -0.0005 -0.0584 -0.223 -0.2474 -0.6485 -0.9521 -1.0342

Additional creep loss in stage II cables on account of PLACING of SIDL :


Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Stages
Creep loss from 64 To day 92 Tonne 0 0.00011 -0.0003 -0.035 -0.1336 -0.1483 -0.3887 -0.5707 -0.6199
Creep loss from 92 To day 36500 Tonne 0 0.00018 -0.0005 -0.0584 -0.223 -0.2474 -0.6485 -0.9521 -1.0342

EPC Contractor-M/s Krishna Constructions 78


Design ch-109+720
Design of PSC Girder

SUMMARY OF LOSSES IN STAGE I CABLES :


1) CREEP LOSS :
Losses In ACTION Losess Type From day t1 to day t2 Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Creep loss from 14 To day 28 Tonne 12.0489 12.045 12.0432 14.8898 20.0999 20.1 19.9633 19.7136 19.57
Creep loss from 28 To day 35 Tonne 1.52003 1.51953 1.51931 1.87842 2.5357 2.53572 2.51847 2.48697 2.469
Creep loss from 35 To day 63 Tonne 3.7346 3.73338 3.73282 4.61514 6.23001 6.23005 6.18768 6.11029 6.066
Creep loss from 63 To day 64 Tonne 0.09845 0.09841 0.0984 0.12166 0.16423 0.16423 0.16311 0.16107 0.16
Creep loss from 64 To day 92 Tonne 2.27274 2.272 2.27166 2.80861 3.79136 3.79139 3.7656 3.7185 3.691
Stage I cableStressing of Creep
stage-Iloss
cables
from 92 To day 36500 Tonne 19.6841 19.6776 19.6747 24.3251 32.8367 32.8369 32.6136 32.2057 31.97

Creep loss from 14 To day 28 Tonne 0 0 0 0 0 0 0 0 0


Creep loss from 28 To day 35 Tonne 0.96593 1.0684 1.16019 2.74808 5.50498 5.70387 8.40244 10.0671 10.34
Creep loss from 35 To day 63 Tonne 0.58197 0.6437 0.69901 1.65571 3.31672 3.43655 5.06242 6.06535 6.228
Creep loss from 63 To day 64 Tonne 0.01252 0.01385 0.01504 0.03562 0.07136 0.07394 0.10892 0.1305 0.134
Creep loss from 64 To day 92 Tonne 0.27398 0.30304 0.32908 0.77947 1.56144 1.61785 2.38328 2.85544 2.932
Stage I cableStressing of Creep
stage-IIloss
cables
from 92 To day 36500 Tonne 2.03912 2.25544 2.44922 5.80134 11.6213 12.0411 17.738 21.2521 21.82

14 To day 28 Tonne 0 0 0 0 0 0 0 0 0
28 To day 35 Tonne 0 0 0 0 0 0 0 0 0
Creep loss from 35 To day 63 Tonne 0.00191 -0.1095 -0.1841 -1.0567 -2.3496 -2.4854 -4.9196 -6.5604 -7.062
Creep loss from 63 To day 64 Tonne 1.9E-05 -0.0011 -0.0019 -0.0108 -0.0239 -0.0253 -0.0501 -0.0668 -0.072
Creep loss from 64 To day 92 Tonne 0.00041 -0.0234 -0.0393 -0.2257 -0.5018 -0.5308 -1.0506 -1.401 -1.508
Stage I cableCasting of Deck
Creep
slab
loss from 92 To day 36500 Tonne 0.00276 -0.1582 -0.266 -1.5265 -3.3941 -3.5903 -7.1066 -9.4767 -10.2

Creep loss from 14 To day 28 Tonne 0 0 0 0 0 0 0 0 0


Creep loss from 28 To day 35 Tonne 0 0 0 0 0 0 0 0 0
Creep loss from 35 To day 63 Tonne 0 0 0 0 0 0 0 0 0
Creep loss from 63 To day 64 Tonne 0 0 0 0 0 0 0 0 0
Creep loss from 64 To day 92 Tonne 0 0 0 0 0 0 0 0 0
Stage I cableTransfer over
Creep
permanent
loss from
bearings 92 To day 36500 Tonne 0 0 0 0 0 0 0 0 0

Creep loss from 14 To day 28 Tonne 0 0 0 0 0 0 0 0 0


Creep loss from 28 To day 35 Tonne 0 0 0 0 0 0 0 0 0
Creep loss from 35 To day 63 Tonne 0 0 0 0 0 0 0 0 0
Creep loss from 63 To day 64 Tonne 0 0 0 0 0 0 0 0 0
Creep loss from 64 64 To day 92 Tonne 0 -0.0169 -0.0314 -0.205 -0.4652 -0.4958 -0.9011 -1.1592 -1.239
Stage I cablePlacing of SIDL
Creep loss from 92 92 To day 36500 Tonne 0 -0.0283 -0.0524 -0.342 -0.776 -0.8272 -1.5033 -1.9338 -2.067

EPC Contractor-M/s Krishna Constructions 79


Design ch-109+720
Design of PSC Girder

Total Creep losses at different stages


Losses In ACTION Losess Type From day t1 to day t2 Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Creep loss from 14 To day 28 Tonne 12.0489 12.045 12.0432 14.8898 20.0999 20.1 19.9633 19.7136 19.57
Creep loss from 28 To day 35 Tonne 2.48596 2.58793 2.6795 4.62651 8.04067 8.23958 10.9209 12.554 12.81
Creep loss from 35 To day 63 Tonne 4.31847 4.26757 4.24771 5.21411 7.19713 7.18116 6.33046 5.61528 5.232
Creep loss from 63 To day 64 Tonne 0.11099 0.11115 0.11156 0.14652 0.21166 0.21286 0.22194 0.22478 0.222
Creep loss from 64 To day 92 Tonne 2.54713 2.53471 2.53003 3.15738 4.38588 4.38262 4.19713 4.01374 3.876
Stage I cableStage-I + StageII
Creep+ loss
Deckfrom
+ Brg. Transfer + SIDL 92 To day 36500 Tonne 21.7259 21.7466 21.8056 28.258 40.2879 40.4606 41.7416 42.0472 41.52

Total Creep loss Tonne 43.2374 43.293 43.4176 56.2923 80.2231 80.5768 83.3754 84.1687 83.23

2) IMMEDIATE LOSSES AFTER FIRST STAGE PRE-STRESSING :


Losses In ACTION Losess Type Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Friction & slip At day 14 Tonne 58.6611 58.3743 58.1225 55.3862 52.5738 52.1338 45.4546 38.7891 32.76
Elastic shortening Tonne 16.9162 16.9162 16.9162 16.9162 16.9162 16.9162 16.9162 16.9162 16.92
Stage I cableStressing of stage-I cables
Total Tonne 75.5773 75.2904 75.0387 72.3024 69.4899 69.05 62.3707 55.7053 49.67

TIME DEPENDENT LOSSES AFTER I STAGE PRESTRESSING :


3) Relaxation Loss : For Stage-I cable, On account of Stage-I cable prestressing
Losses In ACTION Losess Type From day t1 to day t2 Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Relaxation loss from 14 To day 28 Tonne 11.2183 11.2441 11.2668 11.521 11.785 11.8265 12.4623 13.1763 14.03
Relaxation loss from 28 To day 35 Tonne 0.8139 0.81577 0.81742 0.83586 0.85502 0.85803 0.90415 0.95595 1.018
Relaxation loss from 35 To day 63 Tonne 1.33579 1.33887 1.34157 1.37184 1.40328 1.40822 1.48392 1.56894 1.671
Relaxation loss from 63 To day 64 Tonne 0.00147 0.00147 0.00147 0.00151 0.00154 0.00155 0.00163 0.00172 0.002
Relaxation loss from 64 To day 92 Tonne 0.04108 0.04117 0.04126 0.04219 0.04316 0.04331 0.04564 0.04825 0.051
Stage I cableStressing of Relaxation
stage-I cables
loss from 92 To day 36500 Tonne 26.6611 26.7225 26.7764 27.3805 28.008 28.1066 29.6176 31.3144 33.34

Total Relaxation loss Tonne 40.0716 40.1638 40.2449 41.1529 42.096 42.2442 44.5152 47.0655 50.11

EPC Contractor-M/s Krishna Constructions 80


Design ch-109+720
Design of PSC Girder

4) Shrinkage Loss : For Stage-I cable, On account of Stage-I cable prestressing


Losses In ACTION Losess Type From day t1 to day t2 Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Shrinkage loss from 14 To day 28 Tonne 2.42071 2.42071 2.42071 2.42071 2.42071 2.42071 2.42071 2.42071 2.421
Shrinkage loss from 28 To day 35 Tonne 0.98839 0.98839 0.98839 0.98839 0.98839 0.98839 0.98839 0.98839 0.988
Shrinkage loss from 35 To day 63 Tonne 3.16214 3.16214 3.16214 3.16214 3.16214 3.16214 3.16214 3.16214 3.162
Shrinkage loss from 63 To day 64 Tonne 0.09597 0.09597 0.09597 0.09597 0.09597 0.09597 0.09597 0.09597 0.096
Shrinkage loss from 64 To day 92 Tonne 2.36045 2.36045 2.36045 2.36045 2.36045 2.36045 2.36045 2.36045 2.36
Stage I cableStressing of Shrinkage
stage-I cables
loss from 92 To day 36500 Tonne 19.9386 19.9386 19.9386 19.9386 19.9386 19.9386 19.9386 19.9386 19.94

Total Shrinkage loss Tonne 28.9662 28.9662 28.9662 28.9662 28.9662 28.9662 28.9662 28.9662 28.97

5) IMMIDIATE LOSES IN STAGE I CABLES DUE TO ELASTIC SHORTENING LOSSES DUE TO II STAGE PRE-STRESSING
Losses In ACTION Losess Type Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
At day 28 Elastic shortening Tonne 18.2181 18.2181 18.2181 18.2181 18.2181 18.2181 18.2181 18.2181 18.22
Stage I cableStressing of stage-II cables

LOSSES IN PRE-STRESS FORCE OF STAGE I CABLES AT DIFFERENT STAGES :


Losses In ACTION Losess Type From day t1 to day t2 Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Fr+slip+ES of Stage I cable At day 14 75.5773 75.2904 75.0387 72.3024 69.4899 69.05 62.3707 55.7053 49.67

Cr+ Rex+ Sh 14 To day 28 Tonne 25.6879 25.7098 25.7307 28.8315 34.3056 34.3472 34.8463 35.3106 36.02

ES due to stage II cables At day 28 Tonne 18.2181 18.2181 18.2181 18.2181 18.2181 18.2181 18.2181 18.2181 18.22

Cr+ Rex+ Sh 28 To day 35 Tonne 4.28825 4.3921 4.48531 6.45076 9.88408 10.086 12.8134 14.4984 14.81

Cr+ Rex+ Sh 35 To day 63 Tonne 8.81641 8.76858 8.75142 9.74809 11.7625 11.7515 10.9765 10.3464 10.06

Cr+ Rex+ Sh 63 To day 64 Tonne 0.20842 0.20859 0.20901 0.244 0.30918 0.31038 0.31954 0.32247 0.32

Cr+ Rex+ Sh 64 To day 92 Tonne 4.94866 4.93634 4.93174 5.56003 6.78949 6.78638 6.60322 6.42244 6.288

Cr+ Rex+ Sh 92 To day 36500 Tonne 68.3256 68.4076 68.5205 75.5771 88.2345 88.5057 91.2977 93.3002 94.8
Stage I cable

EPC Contractor-M/s Krishna Constructions 81


Design ch-109+720
Design of PSC Girder

Total Shrinkage loss Tonne 206.071 205.932 205.885 216.932 238.993 239.055 237.446 234.124 230.2

CUMULATIVE LOSSES IN STAGE-I CABLES AT DIFFERENT STAGES :


Losses In ACTION Losess Type Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Fr+slip+ES of Stage I cable At day 14 75.5773 75.2904 75.0387 72.3024 69.4899 69.05 62.3707 55.7053 49.67

Cr+ Rex+ Sh 14 To day 28 Tonne 101.265 101 100.769 101.134 103.796 103.397 97.217 91.0159 85.69

ES due to stage II cables At day 28 Tonne 119.483 119.218 118.987 119.352 122.014 121.615 115.435 109.234 103.9

Cr+ Rex+ Sh 28 To day 35 Tonne 123.771 123.61 123.473 125.803 131.898 131.701 128.249 123.732 118.7

Cr+ Rex+ Sh 35 To day 63 Tonne 132.588 132.379 132.224 135.551 143.66 143.453 139.225 134.079 128.8

Cr+ Rex+ Sh 63 To day 64 Tonne 132.796 132.588 132.433 135.795 143.969 143.763 139.545 134.401 129.1

Cr+ Rex+ Sh 64 To day 92 Tonne 137.745 137.524 137.365 141.355 150.759 150.55 146.148 140.824 135.4

Cr+ Rex+ Sh 92 To day 36500 Tonne 206.071 205.932 205.885 216.932 238.993 239.055 237.446 234.124 230.2
Stage I cable

EPC Contractor-M/s Krishna Constructions 82


Design ch-109+720
Design of PSC Girder

FORCES LEFT IN STAGE I CABLES AT DIFFERENT STAGES :


Losses In ACTION Losess Type Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Forces in stage I cables before Friction & slip loss before 14 Tonne 673.926 673.926 673.926 674.001 674.085 674.099 674.3 674.494 674.5
Eccentricity of cables from cg. of precast section 0.77853 0.78589 0.79234 0.84186 0.8844 0.89157 0.97786 1.02154 1.027
At day 14 P Tonne 598.349 598.636 598.888 601.698 604.595 605.049 611.929 618.789 624.9
M Tm 465.835 470.46 474.525 506.548 534.703 539.445 598.384 632.116 642

14 To day 28 P Tonne 572.661 572.926 573.157 572.867 570.29 570.701 577.083 583.478 588.9
M Tm 445.836 450.255 454.137 482.276 504.363 508.822 564.309 596.045 605

At day 28 P Tonne 554.443 554.708 554.939 554.649 552.072 552.483 558.865 565.26 570.6
M Tm 431.653 435.938 439.702 466.939 488.251 492.579 546.494 577.435 586.2

28 To day 35 P Tonne 550.155 550.316 550.454 548.198 542.188 542.397 546.051 550.762 555.8
M Tm 428.314 432.486 436.148 461.508 479.509 483.587 533.964 562.624 571

35 To day 63 P Tonne 541.338 541.547 541.702 538.45 530.425 530.646 535.075 540.415 545.8
M Tm 421.45 425.595 429.214 453.302 469.107 473.11 523.231 552.055 560.7

63 To day 64 P Tonne 541.13 541.339 541.493 538.206 530.116 530.335 534.755 540.093 545.4
M Tm 421.288 425.431 429.048 453.096 468.833 472.833 522.918 551.725 560.4

64 To day 92 P Tonne 536.181 536.402 536.561 532.646 523.326 523.549 528.152 533.67 539.1
M Tm 417.435 421.552 425.141 448.416 462.829 466.782 516.461 545.165 553.9

92 To day 36500 P Tonne 467.856 467.995 468.041 457.069 435.092 435.043 436.854 440.37 444.3
M Tm 364.241 367.791 370.849 384.79 384.794 387.873 427.184 449.855 456.5
Stage I cable

EPC Contractor-M/s Krishna Constructions 83


Design ch-109+720
Design of PSC Girder

STRESSES IN SECTION AT DIFFERENT STAGES DUE TO STAG-I PRE-STRESSING FORCES :


Losses In ACTION Losess Type Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Properties of precast section alone
Area m2 1.92971 1.92971 1.92971 1.43945 0.94469 0.94469 0.94469 0.94469 0.945
Ib m4 0.87202 0.87202 0.87202 0.74007 0.60691 0.60691 0.60691 0.60691 0.607
yb m 1.16766 1.16766 1.16766 1.16004 1.15235 1.15235 1.15235 1.15235 1.152
yt m 1.13234 1.13234 1.13234 1.13996 1.14765 1.14765 1.14765 1.14765 1.148

Stress at girder top At day 14 Mpa -2.9483 -3.0069 -3.0583 -3.6225 -3.7112 -3.796 -4.8377 -5.403 -5.525
Stress at girder bottom Mpa 9.33839 9.40181 9.45754 12.1201 16.5525 16.6473 17.8393 18.5524 18.8

Stress at girder top 14 To day 28 Mpa -2.8217 -2.8777 -2.9269 -3.449 -3.5006 -3.5806 -4.5622 -5.0947 -5.206
Stress at girder bottom Mpa 8.93748 8.99803 9.0512 11.5393 15.6133 15.7023 16.8234 17.4937 17.72

Stress at girder top At day 28 Mpa -2.7319 -2.7862 -2.8339 -3.3393 -3.3888 -3.4663 -4.4182 -4.9356 -5.045
Stress at girder bottom Mpa 8.65315 8.71191 8.76351 11.1724 15.1145 15.2011 16.2923 16.9475 17.17

Stress at girder top 28 To day 35 Mpa -2.7108 -2.7642 -2.811 -3.3004 -3.3281 -3.403 -4.3169 -4.809 -4.914
Stress at girder bottom Mpa 8.58622 8.64293 8.69267 11.0424 14.8439 14.9236 15.9188 16.5128 16.73

Stress at girder top 35 To day 63 Mpa -2.6674 -2.7201 -2.7663 -3.2417 -3.2559 -3.3292 -4.2301 -4.7187 -4.825
Stress at girder bottom Mpa 8.44863 8.50521 8.55447 10.8461 14.5219 14.6002 15.5988 16.2026 16.42

Stress at girder top 63 To day 64 Mpa -2.6664 -2.7191 -2.7652 -3.2403 -3.254 -3.3273 -4.2276 -4.7159 -4.822
Stress at girder bottom Mpa 8.44537 8.50194 8.55117 10.8411 14.5134 14.5917 15.5894 16.1929 16.41

Stress at girder top 64 To day 92 Mpa -2.642 -2.6943 -2.7401 -3.2068 -3.2123 -3.2847 -4.1754 -4.6598 -4.767
Stress at girder bottom Mpa 8.36814 8.42441 8.47329 10.7291 14.3275 14.405 15.3969 16.0004 16.22

Stress at girder top 92 To day 36500 Mpa -2.3053 -2.3507 -2.3901 -2.7518 -2.6707 -2.7294 -3.4536 -3.8451 -3.929
Stress at girder bottom Mpa 7.30179 7.35004 7.39123 9.20679 11.9119 11.9698 12.7354 13.2031 13.37
Stage I cableStresses at different sections at different stages

EPC Contractor-M/s Krishna Constructions 84


Design ch-109+720
Design of PSC Girder

SUMMARY OF LOSSES IN STAGE II CABLES :


1) CREEP LOSS :
Losses In ACTION Losess Type Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Creep loss from 14 To day 28 Tonne 0 0 0 0 0 0 0 0 0
Creep loss from 28 To day 35 Tonne 1.69106 1.65889 1.63083 1.90054 2.69941 2.67956 2.59447 2.63708 2.55962
Creep loss from 35 To day 63 Tonne 1.01885 0.99947 0.98257 1.14507 1.62638 1.61442 1.56315 1.58883 1.54216
Creep loss from 63 To day 64 Tonne 0.02192 0.0215 0.02114 0.02464 0.03499 0.03473 0.03363 0.03418 0.03318
Creep loss from 64 To day 92 Tonne 0.47965 0.47053 0.46257 0.53907 0.76566 0.76003 0.7359 0.74799 0.72601
Stage II cable
Stressing of Creep
stage-IIloss
cables
from 92 To day 36500 Tonne 3.56991 3.50199 3.44276 4.01214 5.69858 5.65668 5.47705 5.56701 5.40348

14 To day 28 Tonne 0 0 0 0 0 0 0 0 0
28 To day 35 Tonne 0 0 0 0 0 0 0 0 0
Creep loss from 35 To day 63 Tonne -0.0005 0.02572 0.0391 0.03568 -0.2492 -0.312 -1.6596 -2.8256 -3.126
Creep loss from 63 To day 64 Tonne -5E-06 0.00026 0.0004 0.00036 -0.0025 -0.0032 -0.0169 -0.0288 -0.0318
Creep loss from 64 To day 92 Tonne -0.0001 0.00549 0.00835 0.00762 -0.0532 -0.0666 -0.3544 -0.6034 -0.6676
Stage II cable
Casting of Deck
Creep
slab
loss from 92 To day 36500 Tonne -0.0007 0.03715 0.05648 0.05154 -0.3599 -0.4507 -2.3974 -4.0816 -4.5157

Creep loss from 14 To day 28 Tonne 0 0 0 0 0 0 0 0 0


Creep loss from 28 To day 35 Tonne 0 0 0 0 0 0 0 0 0
Creep loss from 35 To day 63 Tonne 0 0 0 0 0 0 0 0 0
Creep loss from 63 To day 64 Tonne 0 0 0 0 0 0 0 0 0
Creep loss from 64 To day 92 Tonne 0 0 0 0 0 0 0 0 0
Stage II cable
Transfer over
Creep
permanent
loss from
bearings 92 To day 36500 Tonne 0 0 0 0 0 0 0 0 0

Creep loss from 14 To day 28 Tonne 0 0 0 0 0 0 0 0 0


Creep loss from 28 To day 35 Tonne 0 0 0 0 0 0 0 0 0
Creep loss from 35 To day 63 Tonne 0 0 0 0 0 0 0 0 0
Creep loss from 63 To day 64 Tonne 0 0 0 0 0 0 0 0 0
Creep loss from 64 64 To day 92 Tonne 0 0.00011 -0.0003 -0.035 -0.1336 -0.1483 -0.3887 -0.5707 -0.6199
Stage II cable
Placing of SIDL
Creep loss from 92 92 To day 36500 Tonne 0 0.00018 -0.0005 -0.0584 -0.223 -0.2474 -0.6485 -0.9521 -1.0342

EPC Contractor-M/s Krishna Constructions 85


Design ch-109+720
Design of PSC Girder

Total Creep losses at different stages


Losses In ACTION Losess Type Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Creep loss from 14 To day 28 Tonne 0 0 0 0 0 0 0 0 0
Creep loss from 28 To day 35 Tonne 1.69106 1.65889 1.63083 1.90054 2.69941 2.67956 2.59447 2.63708 2.55962
Creep loss from 35 To day 63 Tonne 1.01836 1.02519 1.02166 1.18074 1.37721 1.3024 -0.0965 -1.2367 -1.5839
Creep loss from 63 To day 64 Tonne 0.02192 0.02177 0.02154 0.025 0.03245 0.03156 0.01674 0.00542 0.00136
Creep loss from 64 To day 92 Tonne 0.47955 0.47613 0.47064 0.51168 0.57881 0.5451 -0.0072 -0.4262 -0.5615
Stage II cable
StageII + Deck
Creep
+ Brg.
lossTransfer
from + SIDL 92 To day 36500 Tonne 3.56919 3.53933 3.49878 4.00526 5.1157 4.95856 2.43117 0.53327 -0.1464

Total Creep loss Tonne 6.78007 6.7213 6.64345 7.62322 9.80358 9.51718 4.93864 1.51289 0.2692

2) IMMIDIATE LOSES IN STAGE II CABLES DUE TO ELASTIC SHORTENING LOSSES DUE TO II STAGE PRE-STRESSING
Losses In ACTION Losess Type Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Friction & slip At day 28 Tonne 47.7555 47.5778 47.4219 44.4962 41.3509 40.8589 33.3892 25.9196 23.6739
Elastic shortening 4.8593 4.8593 4.8593 4.8593 4.8593 4.8593 4.8593 4.8593 4.8593
Stage II cable
Stressing of stage-II cables
Immediate loss Tonne 52.6148 52.4371 52.2812 49.3555 46.2102 45.7182 38.2485 30.7789 28.5332

TIME DEPENDENT LOSSES AFTER II STAGE PRESTRESSING :


3) Relaxation Loss : For Stage-II cable,
Losses In ACTION Losess Type Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Relaxation loss from 14 To day 28 Tonne 0 0 0 0 0 0 0 0 0
Relaxation loss from 28 To day 35 Tonne 6.0018 6.01611 6.02868 6.26605 6.52456 6.56531 7.19432 8.04863 8.34077
Relaxation loss from 35 To day 63 Tonne 1.56691 1.57065 1.57393 1.6359 1.70339 1.71403 1.87825 2.10128 2.17755
Relaxation loss from 63 To day 64 Tonne 0.03753 0.03762 0.0377 0.03918 0.0408 0.04105 0.04499 0.05033 0.05216
Relaxation loss from 64 To day 92 Tonne 0.23186 0.23241 0.23289 0.24206 0.25205 0.25362 0.27792 0.31093 0.32221
Stage II cable
Stressing of Relaxation
stage-II cables
loss from 92 To day 36500 Tonne 15.6187 15.6559 15.6886 16.3063 16.979 17.0851 18.722 20.9452 21.7054

Total Relaxation loss Tonne 23.4568 23.5127 23.5618 24.4895 25.4999 25.6591 28.1175 31.4563 32.5981

EPC Contractor-M/s Krishna Constructions 86


Design ch-109+720
Design of PSC Girder

4) Shrinkage Loss : For Stage-II cable,


Losses In ACTION Losess Type Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Shrinkage loss from 14 To day 28 Tonne 0 0 0 0 0 0 0 0 0
Shrinkage loss from 28 To day 35 Tonne 0.61774 0.61774 0.61774 0.61774 0.61774 0.61774 0.61774 0.61774 0.61774
Shrinkage loss from 35 To day 63 Tonne 1.97634 1.97634 1.97634 1.97634 1.97634 1.97634 1.97634 1.97634 1.97634
Shrinkage loss from 63 To day 64 Tonne 0.05998 0.05998 0.05998 0.05998 0.05998 0.05998 0.05998 0.05998 0.05998
Shrinkage loss from 64 To day 92 Tonne 1.47528 1.47528 1.47528 1.47528 1.47528 1.47528 1.47528 1.47528 1.47528
Stage II cable
Stressing of Shrinkage
stage-II cables
loss from 92 To day 36500 Tonne 12.4616 12.4616 12.4616 12.4616 12.4616 12.4616 12.4616 12.4616 12.4616

Total Shrinkage loss Tonne 16.5909 16.5909 16.5909 16.5909 16.5909 16.5909 16.5909 16.5909 16.5909

LOSSES IN PRE-STRESS FORCE OF STAGE II CABLES AT DIFFERENT STAGES :


Losses In ACTION Losess Type Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
- At day 14

- 14 To day 28 Tonne

Fr+slip+ES of Stage II cable At day 28 Tonne 52.6148 52.4371 52.2812 49.3555 46.2102 45.7182 38.2485 30.7789 28.5332

Cr+ Rex+ Sh 28 To day 35 Tonne 8.31061 8.29274 8.27726 8.78434 9.84171 9.86262 10.4065 11.3035 11.5181

Cr+ Rex+ Sh 35 To day 63 Tonne 4.5616 4.57217 4.57193 4.79298 5.05694 4.99276 3.75809 2.84089 2.57002

Cr+ Rex+ Sh 63 To day 64 Tonne 0.11943 0.11937 0.11922 0.12416 0.13324 0.13259 0.1217 0.11573 0.11349

Cr+ Rex+ Sh 64 To day 92 Tonne 2.18669 2.18382 2.17882 2.22902 2.30614 2.27401 1.74597 1.36005 1.23599

Cr+ Rex+ Sh 92 To day 36500 Tonne 31.6494 31.6568 31.649 32.7732 34.5563 34.5053 33.6148 33.94 34.0206
Stage II cable

Total Loss Tonne 99.4426 99.2621 99.0774 98.0592 98.1046 97.4854 87.8956 80.3391 77.9915

EPC Contractor-M/s Krishna Constructions 87


Design ch-109+720
Design of PSC Girder

Cumulative losses in Stage -II cables at different stages


Losses In ACTION Losess Type Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
- At day 14 0 0 0 0 0 0 0 0 0

- 14 To day 28 Tonne 0 0 0 0 0 0 0 0 0

Fr+slip+ES of Stage II cable At day 28 Tonne 52.6148 52.4371 52.2812 49.3555 46.2102 45.7182 38.2485 30.7789 28.5332

Cr+ Rex+ Sh 28 To day 35 Tonne 60.9254 60.7299 60.5584 58.1398 56.0519 55.5808 48.6551 42.0824 40.0513

Cr+ Rex+ Sh 35 To day 63 Tonne 65.487 65.3021 65.1304 62.9328 61.1089 60.5736 52.4132 44.9233 42.6214

Cr+ Rex+ Sh 63 To day 64 Tonne 65.6064 65.4214 65.2496 63.057 61.2421 60.7062 52.5349 45.039 42.7349

Cr+ Rex+ Sh 64 To day 92 Tonne 67.7931 67.6052 67.4284 65.286 63.5482 62.9802 54.2808 46.399 43.9708

Cr+ Rex+ Sh 92 To day 36500 Tonne 99.4426 99.2621 99.0774 98.0592 98.1046 97.4854 87.8956 80.3391 77.9915
Stage II cable

EPC Contractor-M/s Krishna Constructions 88


Design ch-109+720
Design of PSC Girder

FORCES LEFT IN STAGE II CABLES AT DIFFERENT STAGES :


Losses In ACTION Losess Type Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Forces in stage II cables before Friction & slip loss before 28 Tonne 421.59 421.59 421.59 421.59 421.59 421.59 421.59 421.59 421.59
Eccentricity of cables from cg. of precast section m -0.3251 -0.2953 -0.2692 -0.0455 0.15006 0.17908 0.52781 0.70396 0.72766

At day 14 P Tonne
M Tm

14 To day 28 P Tonne
M Tm

At day 28 P Tonne 368.975 369.153 369.309 372.234 375.38 375.872 383.341 390.811 393.057
M Tm -119.94 -109.02 -99.42 -16.929 56.3291 67.3126 202.333 275.117 286.012

28 To day 35 P Tonne 360.665 360.86 361.031 363.45 365.538 366.009 372.935 379.508 381.539
M Tm -117.24 -106.57 -97.192 -16.529 54.8523 65.5464 196.84 267.16 277.631

35 To day 63 P Tonne 356.103 356.288 356.46 358.657 360.481 361.016 369.177 376.667 378.969
M Tm -115.76 -105.22 -95.961 -16.311 54.0934 64.6523 194.856 265.16 275.761

63 To day 64 P Tonne 355.983 356.168 356.34 358.533 360.348 360.884 369.055 376.551 378.855
M Tm -115.72 -105.18 -95.929 -16.306 54.0735 64.6285 194.792 265.079 275.678

64 To day 92 P Tonne 353.797 353.985 354.162 356.304 358.042 358.61 367.309 375.191 377.619
M Tm -115.01 -104.54 -95.343 -16.204 53.7274 64.2213 193.871 264.121 274.779

92 To day 36500 P Tonne 322.147 322.328 322.513 323.531 323.485 324.104 333.694 341.251 343.598
Stage II cable
Forces at different sections at different stages M Tm -104.72 -95.19 -86.822 -14.714 48.5419 58.042 176.128 240.229 250.024

EPC Contractor-M/s Krishna Constructions 89


Design ch-109+720
Design of PSC Girder

FORCES LEFT IN (I+ II) STAGE CABLES AT DIFFERENT STAGES :


Losses In ACTION Losess Type Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
At day 14 P Tonne 598.349 598.636 598.888 601.698 604.595 605.049 611.929 618.789 624.87
M Tm 465.835 470.46 474.525 506.548 534.703 539.445 598.384 632.116 641.961

14 To day 28 P Tonne 572.661 572.926 573.157 572.867 570.29 570.701 577.083 583.478 588.851
M Tm 445.836 450.255 454.137 482.276 504.363 508.822 564.309 596.045 604.956

At day 28 P Tonne 923.418 923.861 924.248 926.883 927.451 928.355 942.206 956.071 963.689
M Tm 311.712 326.92 340.282 450.01 544.58 559.892 748.827 852.552 872.253

28 To day 35 P Tonne 910.819 911.176 911.485 911.648 907.726 908.406 918.986 930.269 937.36
M Tm 311.075 325.917 338.956 444.979 534.362 549.133 730.804 829.784 848.655

35 To day 63 P Tonne 897.441 897.835 898.162 897.107 890.906 891.662 904.251 917.082 924.725
M Tm 305.694 320.376 333.253 436.991 523.2 537.762 718.087 817.215 836.445

63 To day 64 P Tonne 897.113 897.507 897.833 896.739 890.464 891.219 903.81 916.644 924.292
M Tm 305.571 320.248 333.119 436.791 522.907 537.461 717.71 816.804 836.034

64 To day 92 P Tonne 889.978 890.387 890.723 888.95 881.368 882.159 895.461 908.861 916.768
M Tm 302.429 317.013 329.798 432.211 516.556 531.004 710.332 809.286 828.675

92 To day 36500 P Tonne 790.003 790.323 790.553 780.599 758.577 759.148 770.548 781.621 787.944
Stage (I+ II) cable
Forces at different sections at different stages M Tm 259.523 272.601 284.027 370.076 433.336 445.915 603.312 690.083 706.522

Equivalentmeccentricity from cg.


0.32851
of precast
0.34492
section0.35928 0.47409 0.57125 0.58739 0.78297 0.88289 0.89667
Equivalentmeccentricity from top
1.46085
of precast
1.47727
section
1.49162 1.61405 1.7189 1.73504 1.93061 2.03054 2.04431

Forces just after friction & slip Horizontal component T 978.042 978.507 978.915 984.635 990.659 991.601 1005.91 1020.19 1028.51
Forces just after friction & slip Vertical component T 71.6957 71.7305 71.761 63.9823 55.0768 53.6837 32.5344 11.365 0

Vertical component after all losses T 57.9114 57.9354 57.9528 50.7239 42.174 41.0991 24.9221 8.70733 0

EPC Contractor-M/s Krishna Constructions 90


Design ch-109+720
Design of PSC Girder

STRESSES IN SECTION AT DIFFERENT STAGES DUE TO II STAGE PRE-STRESSING FORCES :


Losses In ACTION Stresses at Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Properties of precast section alone
Area m2 1.92971 1.92971 1.92971 1.43945 0.94469 0.94469 0.94469 0.94469 0.94469
Ib m4 0.87202 0.87202 0.87202 0.74007 0.60691 0.60691 0.60691 0.60691 0.60691
yb m 1.16766 1.16766 1.16766 1.16004 1.15235 1.15235 1.15235 1.15235 1.15235
yt m 1.13234 1.13234 1.13234 1.13996 1.14765 1.14765 1.14765 1.14765 1.14765
Stress at girder top At day 14 Mpa 0 0 0 0 0 0 0 0 0
Stress at girder bottom Mpa 0 0 0 0 0 0 0 0 0

Stress at girder top 14 To day 28 Mpa 0 0 0 0 0 0 0 0 0


Stress at girder bottom Mpa 0 0 0 0 0 0 0 0 0

Stress at girder top At day 28 Mpa 3.46954 3.32863 3.20481 2.84671 2.90841 2.70593 0.2318 -1.0655 -1.2477
Stress at girder bottom Mpa 0.30604 0.45321 0.58254 2.3206 5.04312 5.25688 7.89961 9.36066 9.5913

Stress at girder top 28 To day 35 Mpa 3.3914 3.25386 3.13298 2.77953 2.83216 2.63492 0.22551 -1.0347 -1.2112
Stress at girder bottom Mpa 0.29914 0.44303 0.56948 2.26583 4.9109 5.11894 7.68516 9.08992 9.31024

Stress at girder top 35 To day 63 Mpa 3.3485 3.21263 3.09331 2.74287 2.79298 2.59898 0.22323 -1.0269 -1.203
Stress at girder bottom Mpa 0.29536 0.43742 0.56227 2.23595 4.84296 5.04911 7.60771 9.02188 9.24753

Stress at girder top 63 To day 64 Mpa 3.34738 3.21155 3.09227 2.74192 2.79195 2.59803 0.22316 -1.0266 -1.2026
Stress at girder bottom Mpa 0.29526 0.43727 0.56208 2.23518 4.84117 5.04726 7.60521 9.0191 9.24476

Stress at girder top 64 To day 92 Mpa 3.32682 3.19186 3.07336 2.72488 2.77408 2.58166 0.2221 -1.0229 -1.1987
Stress at girder bottom Mpa 0.29345 0.43459 0.55865 2.22128 4.81019 5.01545 7.56923 8.98653 9.2146

Stress at girder top 92 To day 36500 Mpa 3.02921 2.90641 2.79872 2.47424 2.50634 2.33325 0.20178 -0.9304 -1.0907
Stress at girder bottom Mpa 0.2672 0.39572 0.50872 2.01697 4.34594 4.53287 6.87652 8.1736 8.38443
Stage II cable
Stresses at different sections at different stages

EPC Contractor-M/s Krishna Constructions 91


Design ch-109+720
Design of PSC Girder

STRESSES IN SECTION AT DIFFERENT STAGES DUE TO (I + II) STAGE PRE-STRESSING FORCES :


Losses In ACTION Losess Type Sections Unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Properties of precast section alone
Area m2 1.92971 1.92971 1.92971 1.43945 0.94469 0.94469 0.94469 0.94469 0.94469
Ib m4 0.87202 0.87202 0.87202 0.74007 0.60691 0.60691 0.60691 0.60691 0.60691
yb m 1.16766 1.16766 1.16766 1.16004 1.15235 1.15235 1.15235 1.15235 1.15235
yt m 1.13234 1.13234 1.13234 1.13996 1.14765 1.14765 1.14765 1.14765 1.14765

Stress at girder top At day 14 Mpa -2.9483 -3.0069 -3.0583 -3.6225 -3.7112 -3.796 -4.8377 -5.403 -5.5248
Stress at girder bottom Mpa 9.33839 9.40181 9.45754 12.1201 16.5525 16.6473 17.8393 18.5524 18.8037

Stress at girder top 14 To day 28 Mpa -2.8217 -2.8777 -2.9269 -3.449 -3.5006 -3.5806 -4.5622 -5.0947 -5.2063
Stress at girder bottom Mpa 8.93748 8.99803 9.0512 11.5393 15.6133 15.7023 16.8234 17.4937 17.7198

Stress at girder top At day 28 Mpa 0.73759 0.54241 0.3709 -0.4926 -0.4803 -0.7603 -4.1864 -6.0011 -6.293
Stress at girder bottom Mpa 8.95919 9.16512 9.34604 13.493 20.1576 20.4579 24.1919 26.3081 26.7628

Stress at girder top 28 To day 35 Mpa 0.68058 0.48969 0.32198 -0.5209 -0.4959 -0.7681 -4.0914 -5.8437 -6.1255
Stress at girder bottom Mpa 8.88537 9.08596 9.26216 13.3082 19.7548 20.0425 23.6039 25.6027 26.0361

Stress at girder top 35 To day 63 Mpa 0.68112 0.49251 0.327 -0.4989 -0.4629 -0.7303 -4.0069 -5.7456 -6.0283
Stress at girder bottom Mpa 8.74399 8.94263 9.11674 13.082 19.3648 19.6493 23.2065 25.2245 25.6705

Stress at girder top 63 To day 64 Mpa 0.68103 0.49248 0.32703 -0.4984 -0.462 -0.7293 -4.0045 -5.7424 -6.0251
Stress at girder bottom Mpa 8.74064 8.93921 9.11326 13.0763 19.3546 19.6389 23.1947 25.212 25.6581

Stress at girder top 64 To day 92 Mpa 0.68485 0.49758 0.33331 -0.4819 -0.4382 -0.7031 -3.9533 -5.6827 -5.9656
Stress at girder bottom Mpa 8.66159 8.859 9.03194 12.9504 19.1377 19.4204 22.9662 24.9869 25.4387

Stress at girder top 92 To day 36500 Mpa 0.72391 0.55574 0.40857 -0.2775 -0.1644 -0.3962 -3.2519 -4.7755 -5.0194
Stress at girder bottom Mpa 7.56899 7.74577 7.89995 11.2238 16.2578 16.5027 19.6119 21.3767 21.7557
Stage I+ II cable
Stresses at different sections at different stages

EPC Contractor-M/s Krishna Constructions 92


Design ch-109+720
Design of PSC Girder

CHECK FOR OUTER/ INNER GIRDER

EPC Contractor-M/s Krishna Constructions 93


Design ch-109+720
Design of PSC Girder

SUMMARY OF FORCES FOR LIVE LOAD (4 LANE LOADING):

Impact Factor For Live Load Lane Reduction Factor For Live Load
Class A Loading = 0.1142 Class AX3 = 10 %
Class 70 RW Loading = 0.1142 Class AX1 + 70 RW = 10 %
Class AX4 = 20 %
Class AX2 + 70 RW = 20 %
Class 70 RWX2 = 20 %
BENDING MOMENT DUE TO LIVE LOAD
Section At unit Face TS deff TE L/8 2L/8 3L/8 4L/8 unit Face TS deff TE L/8 2L/8 3L/8 4L/8
Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7 m 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
OUTER GIRDER INNER GIRDER
70RW Tm 10.965 21.471 114.62 202.82 224.67 358.41 423.91 463.55 Tm 10.293 17.336 80.521 132.62 148.99 201.78 273.58 278.03
Class 2A Tm 8.1794 15.629 80.331 141.2 151.24 260.1 329.44 355.51 Tm 6.4513 11.971 58.54 100.09 117.27 179.21 222.73 243.91
Class 3A Tm 8.0494 15.319 78.906 139.67 148.15 260.73 336.97 360.37 Tm 6.6876 12.533 62.382 108.35 119.83 198.82 254 275.09
Class 1A + 70RW (ecc) Tm 10.48 18.524 87.45 157.18 167.1 300.5 399.15 412 Tm 9.5526 17.374 86.538 148.9 157.63 246.57 281.61 330.85
Class AX4 Tm 6.7931 12.88 65.948 116.52 123.58 215.21 275.06 295.36 Tm 6.2129 11.625 57.962 100.99 109.43 186.7 240.56 258.86
Class AX2 + 70 RW Tm 9.6081 16.921 80.043 133.59 141.1 249.29 325.31 342.45 Tm 8.9306 16.027 70.364 118.75 127.52 209.2 274.09 285.37
Class 70 RWX2 Tm 10.295 21.465 108.86 179.49 202.88 330.28 407.42 438.45 Tm 16.179 26.929 114.16 181.79 191.85 256.36 322.14 329.53
Class 70 RWX2 (2) Tm 9.2613 17.483 97.831 175.31 187.84 320.27 392.28 423.5 Tm 8.6401 14.594 69.732 117.84 128.89 217.3 312.13 318.74
Special Vehicle Loading Tm 7.128 14.513 79.248 141.54 150.99 267 348.51 360.44 Tm 17.032 31.1 141.21 229.35 239.71 324.75 339.15 360.04
Max Live Load (without SV) Tm 10.965 21.471 114.62 202.82 224.67 358.41 423.91 463.55 Tm 16.179 26.929 114.16 181.79 191.85 256.36 322.14 330.85

SHEAR FORCES DUE TO LIVE LOAD


Section At unit Face TS deff TE L/8 2L/8 3L/8 4L/8 unit Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7 m 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
OUTER GIRDER INNER GIRDER
70RW T 56.496 56.939 56.457 51.479 46.715 37.194 26.108 24.668 T 46.942 45.706 39.582 32.344 29.688 22.409 20.388 12.77
Class 2A T 38.427 38.59 38.24 35.461 33.175 27.413 19.377 13.464 T 30.466 30.029 27.792 25.173 24.225 19.928 14.669 8.4368
Class 3A T 37.598 37.772 37.566 35.156 33.102 27.718 19.803 12.126 T 31.992 31.639 29.657 27.281 26.379 21.772 15.877 9.8855
Class 1A + 70RW (ecc) T 47.563 46.435 41.758 39.717 37.723 32.171 24.098 15.865 T 48.54 47.45 42.656 37.095 35.546 24.598 17.512 13.29
Class AX4 T 31.376 31.526 31.358 29.3 27.505 23.054 16.54 10.378 T 29.594 29.288 27.55 25.44 24.634 20.41 14.89 8.9877
Class AX2 + 70 RW T 43.382 42.411 38.118 32.911 31.843 26.452 19.394 12.859 T 38.478 38.472 33.935 28.988 27.88 22.508 16.182 11.938
Class 70 RWX2 T 59.631 59.613 52.579 45.76 42.087 35.182 26.24 19.681 T 64.073 63.099 54.194 43.415 40.599 26.532 23.29 19.833
Class 70 RWX2 (2) T 47.719 48.143 48.185 44.657 40.958 33.97 25.127 19.347 T 39.227 38.936 34.342 29.557 27.6 25.72 22.658 12.788
Special Vehicle Loading T 40.75 40.58 37.816 34.437 33.061 27.838 27.862 12.489 T 26.561 26.286 24.726 22.832 22.109 18.318 13.364 8.0664
Max Live Load (without SV) T 59.631 59.613 56.457 51.479 46.715 37.194 27.862 24.668 T 64.073 63.099 54.194 43.415 40.599 26.532 23.29 19.833

EPC Contractor-M/s Krishna Constructions 94


Design ch-109+720
Design of PSC Girder

SUMMARY OF FORCES FOR OUTER GIRDER :

Impact Factor For LL


Class A = 0.1142
Class 70 R wh. = 0.1142

BENDING MOMENT OUTER GIRDER DUE TO PERMANENT LOAD


Section At unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
Precast Beam Tm -0 -0.0543 -0.7297 8.6895 16.778 84.646 142.08 150.3 253.22 314.97 335.55
Deck Slab & Diaphragm Tm -0.0398 0.1364 -0.1294 7.3472 12.252 56.169 97.493 102.3 184.62 235.67 252.24
Transfer at Permanent Brg.
SIDL Tm 0 0 0 0 0 0 0 0
Surfacing Tm 1.672 3.079 15.56 27.248 28.893 49.39 61.68 65.678
Wind Load Tm 1.646 3.032 15.321 26.828 28.448 48.63 60.731 64.668
Governing LL with Impact
Mz Tm 10.965 21.471 114.62 202.82 224.67 358.41 423.91 463.55
Corresponding Fy Mton T 59.631 59.613 56.457 51.479 46.715 37.194 27.862 24.668

MAX. SHEAR FORCES OUTER GIRDER


Section At unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
Precat Beam T -0 0.7236 2.6533 43.708 42.805 35.469 30.23 29.581 19.72 9.8602 -4E-15
Deck Slab & Diaphragm T 1.6905 1.9382 2.5989 28.55 28.241 25.364 22.46 22.006 15.11 8.2145 1.3189
Transfer at Permanent Brg.
SIDL T 7.964 8.249 8.697 7.796 6.147 4.324 4.5 2.501
Surfacing T 7.917 7.816 7.542 6.704 6.018 5.415 3.453 1.531
Wind load T 7.795 7.695 7.425 6.601 5.926 5.332 3.4 1.507
Governing LL with Impact
Maximum S.F T 59.631 59.613 56.457 51.479 46.715 37.194 27.862 24.668
Corresponding Mz Tm 10.965 21.471 114.62 202.82 224.67 358.41 423.91 463.55

EPC Contractor-M/s Krishna Constructions 95


Design ch-109+720
Design of PSC Girder

SUMMARY OF FORCES FOR INNER GIRDER :

Impact Factor For LL


Class A = 0.11421
Class 70 R wh. = 0.11421

BENDING MOMENT INNER GIRDER DUE TO PERMANENT LOAD


Section At unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
Precast Beam Tm -0 -0.0543 -0.7297 8.6895 16.778 84.646 142.08 150.3 253.22 314.97 335.55
Deck Slab & Diaphragm Tm -0.0434 -0.0787 -0.4733 5.0827 10.351 61.662 106.55 110.76 198.45 253.61 267.86
Transfer at Permanent Brg.
SIDL Tm 0 0 0 0 0 0 0 0
Surfacing Tm 1.633 3.079 15.582 27.288 28.941 49.434 61.442 65.692
Wind Load Tm 1.608 3.031 15.343 26.868 28.495 48.674 60.497 64.681
Governing LL with Impact
Mz Tm 16.179 26.929 114.16 181.79 191.85 256.36 322.14 330.85
Corresponding Fy Mton T 64.073 63.099 54.194 43.415 40.599 26.532 23.29 19.833

MAX. SHEAR FORCES INNER GIRDER


Section At unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
Precat Beam T -0 0.7236 2.6533 43.708 42.805 35.469 30.23 29.581 19.72 9.8602 -4E-15
Deck Slab & Diaphragm T 3.0431 3.3134 4.0341 32.344 32.007 28.868 25.701 25.205 17.683 10.16 2.6377
Transfer at Permanent Brg.
SIDL T 4.033 4.04 4.054 4.139 4.286 4.438 4.603 0.042
Surfacing T 7.94 7.838 7.564 6.723 6.03 5.423 3.393 1.527
Wind load T 7.817 7.718 7.447 6.619 5.937 5.339 3.341 1.503
Governing LL with Impact
Maximum S.F T 64.073 63.099 54.194 43.415 40.599 26.532 23.29 19.833
Corresponding Mz Tm 16.179 26.929 114.16 181.79 191.85 256.36 322.14 330.85

EPC Contractor-M/s Krishna Constructions 96


Design ch-109+720
Design of PSC Girder

CHECK FOR STRESSES : PRESTRESS WITH SUPERIOR LOAD COMBINATION

SLS STRESS CHECK : RARE COMBINATION SUPERIOR


A) OUTER GIRDER SUMMARY OF LOADS
BENDING MOMENT SUMMARY
Section At unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
Precast Beam Tm -0 -0.054 -0.73 8.6895 16.778 84.646 142.08 150.3 253.2 314.966 335.55
Deck Outer Girder Tm -0.04 0.1364 -0.129 7.3472 12.252 56.169 97.493 102.3 184.6 235.668 252.24
Transfer brg. Tm 0 0 0 0 0 0 0 0 0 0 0
SIDL Tm 0 0 0 0 0 0 0 0 0 0 0
Surfacing Tm 0 0 0 1.672 3.079 15.56 27.248 28.893 49.39 61.68 65.678
Wind Load T 0 0 0 1.646 3.032 15.321 26.828 28.448 48.63 60.731 64.668
Live Load (Without SV Loading) Tm 0 0 0 10.965 21.471 114.62 202.82 224.67 358.4 423.907 463.55
Live Load (With SV Loading) Tm 0 0 0 7.128 14.513 79.248 141.54 150.99 267 348.512 360.44

SECTION PROPERTIES
Sections unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Section at m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
Properties of Precast Section
Area m2 1.9297 1.9297 1.9297 1.9297 1.9297 1.4394 0.9447 0.9447 0.945 0.94469 0.9447
I gross m4 0.872 0.872 0.872 0.872 0.872 0.7401 0.6069 0.6069 0.607 0.60691 0.6069
yb m 1.1677 1.1677 1.1677 1.1677 1.1677 1.16 1.1524 1.1524 1.152 1.15235 1.1524
yt m 1.1323 1.1323 1.1323 1.1323 1.1323 1.14 1.1476 1.1476 1.148 1.14765 1.1476
Properties of Composite Section
Area m2 2.5025 2.5025 2.5025 2.5025 2.5025 2.0122 1.5175 1.5175 1.517 1.51748 1.5175
I gross m4 1.556 1.556 1.556 1.556 1.556 1.3655 1.1732 1.1732 1.173 1.17322 1.1732
yb m 1.452 1.452 1.452 1.452 1.452 1.5391 1.6271 1.6271 1.627 1.62707 1.6271
yt m 1.068 1.068 1.068 1.068 1.068 0.9809 0.8929 0.8929 0.893 0.89293 0.8929
Gtop m 0.848 0.848 0.848 0.848 0.848 0.7609 0.6729 0.6729 0.673 0.67293 0.6729

STRESSES DUE TO ACTION OF LOADS :


Section At unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
Precast Beam
Gtop Mpa 0 -7E-04 -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.788 5.95593 6.3452
Girder Gbottom Mpa 0 0.0007 0.0098 -0.116 -0.225 -1.327 -2.698 -2.8538 -4.808 -5.98034 -6.3712

Deck Outer Girder


Gtop Mpa -5E-04 0.0018 -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.491 4.45644 4.7698
Girder Gbottom Mpa 0.0005 -0.002 0.0017 -0.098 -0.164 -0.88 -1.851 -1.9424 -3.505 -4.4747 -4.7893

Transfer brg.
Dtop Mpa 0 0 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0 0 0
Stresses Girder
At Gbottom Mpa 0 0 0 0 0 0 0 0 0 0 0

SIDL
Dtop Mpa 0 0 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0 0 0
Stresses Girder
At Gbottom Mpa 0 0 0 0 0 0 0 0 0 0 0

Section At unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
Surfacing
Dtop Mpa 0 0 0 0.0115 0.0211 0.1118 0.2074 0.2199 0.376 0.46944 0.4999
Deck Dbottom Mpa 0 0 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.283 0.35378 0.3767
Gtop Mpa 0 0 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.283 0.35378 0.3767
Stresses Girder
At Gbottom Mpa 0 0 0 -0.016 -0.029 -0.175 -0.378 -0.4007 -0.685 -0.8554 -0.9108

EPC Contractor-M/s Krishna Constructions 97


Design ch-109+720
Design of PSC Girder

Live Load (Without SV Loading)


Dtop Mpa 0 0 0 0.0753 0.1474 0.8233 1.5436 1.71 2.728 3.22632 3.528
Deck Dbottom Mpa 0 0 0 0.0598 0.117 0.6387 1.1633 1.2887 2.056 2.43142 2.6588
Gtop Mpa 0 0 0 0.0598 0.117 0.6387 1.1633 1.2887 2.056 2.43142 2.6588
Stresses Girder
At Gbottom Mpa 0 0 0 -0.102 -0.2 -1.292 -2.813 -3.1159 -4.971 -5.8789 -6.4286

Live Load (With SV Loading)


Dtop Mpa 0 0 0 0.0489 0.0996 0.5692 1.0773 1.1492 2.032 2.6525 2.7433
Deck Dbottom Mpa 0 0 0 0.0388 0.0791 0.4416 0.8118 0.866 1.531 1.99897 2.0674
Gtop Mpa 0 0 0 0.0388 0.0791 0.4416 0.8118 0.866 1.531 1.99897 2.0674
Stresses Girder
At Gbottom Mpa 0 0 0 -0.067 -0.135 -0.893 -1.963 -2.094 -3.703 -4.8333 -4.9987

Wind Load
Dtop Mpa 0 0 0 0.0113 0.0208 0.1101 0.2042 0.2165 0.37 0.46222 0.4922
Deck Dbottom Mpa 0 0 0 0.009 0.0165 0.0854 0.1539 0.1632 0.279 0.34834 0.3709
Gtop Mpa 0 0 0 0.009 0.0165 0.0854 0.1539 0.1632 0.279 0.34834 0.3709
Stresses Girder
At Gbottom Mpa 0 0 0 -0.015 -0.028 -0.173 -0.372 -0.3945 -0.674 -0.84224 -0.8968

STRESSES DUE TO DIFFERENTIAL SHRINKAGE :


At day 63
Dtop Mpa -0.182 -0.182 -0.182 -0.182 -0.182 -0.162 -0.122 -0.1219 -0.122 -0.12189 -0.1219
Deck Dbottom Mpa -0.224 -0.224 -0.224 -0.224 -0.224 -0.205 -0.167 -0.1668 -0.167 -0.16685 -0.1668
Gtop Mpa 0.2822 0.2822 0.2822 0.2822 0.2822 0.3008 0.3393 0.3393 0.339 0.33932 0.3393
Stresses Girder
At Gbottom Mpa -0.151 -0.151 -0.151 -0.151 -0.151 -0.148 -0.131 -0.1307 -0.131 -0.1307 -0.1307

At day 64
Dtop Mpa -0.182 -0.182 -0.182 -0.182 -0.182 -0.162 -0.122 -0.1218 -0.122 -0.12184 -0.1218
Deck Dbottom Mpa -0.224 -0.224 -0.224 -0.224 -0.224 -0.205 -0.167 -0.1668 -0.167 -0.16678 -0.1668
Gtop Mpa 0.2821 0.2821 0.2821 0.2821 0.2821 0.3007 0.3392 0.3392 0.339 0.33918 0.3392
Stresses Girder
At Gbottom Mpa -0.151 -0.151 -0.151 -0.151 -0.151 -0.148 -0.131 -0.1306 -0.131 -0.13065 -0.1306

At day 92
Dtop Mpa -0.173 -0.173 -0.173 -0.173 -0.173 -0.154 -0.116 -0.1158 -0.116 -0.11579 -0.1158
Deck Dbottom Mpa -0.213 -0.213 -0.213 -0.213 -0.213 -0.195 -0.158 -0.1585 -0.158 -0.15849 -0.1585
Gtop Mpa 0.2681 0.2681 0.2681 0.2681 0.2681 0.2857 0.3223 0.3223 0.322 0.32233 0.3223
Stresses Girder
At Gbottom Mpa -0.144 -0.144 -0.144 -0.144 -0.144 -0.141 -0.124 -0.1242 -0.124 -0.12416 -0.1242

At day 36500
Dtop Mpa -0.713 -0.713 -0.713 -0.713 -0.713 -0.635 -0.477 -0.4765 -0.477 -0.47654 -0.4765
Deck Dbottom Mpa -0.875 -0.875 -0.875 -0.875 -0.875 -0.803 -0.652 -0.6523 -0.652 -0.65231 -0.6523
Gtop Mpa 1.1035 1.1035 1.1035 1.1035 1.1035 1.1759 1.3266 1.3266 1.327 1.32662 1.3266
Stresses Girder
At Gbottom Mpa -0.592 -0.592 -0.592 -0.592 -0.592 -0.58 -0.511 -0.511 -0.511 -0.511 -0.511

STRESSES DUE TO +VE TEMPERATURE STRESSES :


Section At unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
Dtop Mpa 4.52 4.52 4.52 4.6996 4.8808 4.8808 4.881 4.8808 4.8808
Deck Dbottom Mpa -1.32 -1.32 -1.32 -1.196 -1.071 -1.0712 -1.071 -1.07122 -1.0712
Gtop Mpa -1.32 -1.32 -1.32 -1.196 -1.071 -1.0712 -1.071 -1.07122 -1.0712
Stresses Girder
At Gbottom Mpa 2.8058 2.8058 2.8058 2.3486 1.8872 1.8872 1.887 1.88716 1.8872
STRESSES DUE TO -VE TEMPERATURE STRESSES :
Dtop Mpa -2.831 -2.831 -2.831 -2.739 -2.646 -2.6462 -2.646 -2.64619 -2.6462
Deck Dbottom Mpa 0.6502 0.6502 0.6502 0.7612 0.8733 0.8733 0.873 0.87329 0.8733
Gtop Mpa 0.6502 0.6502 0.6502 0.7612 0.8733 0.8733 0.873 0.87329 0.8733
Stresses Girder
At Gbottom Mpa -3.179 -3.179 -3.179 -2.873 -2.564 -2.5638 -2.564 -2.56378 -2.5638

EPC Contractor-M/s Krishna Constructions 98


Design ch-109+720
Design of PSC Girder

STRESSES AT DIFFERENT STAGES DUE TO PRE-STRESSING FORCES :


Load factor Superior load factor = 1.1
Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Gtop At day 14 Mpa -3.243 -3.308 -3.364 -3.985 -4.082 -4.1757 -5.322 -5.94329 -6.0773
Girder Gbottom Mpa 10.272 10.342 10.403 13.332 18.208 18.312 19.62 20.4076 20.684

Gtop 14 To day 28 Mpa -3.104 -3.166 -3.22 -3.794 -3.851 -3.9386 -5.018 -5.60414 -5.7269
Girder Gbottom Mpa 9.8312 9.8978 9.9563 12.693 17.175 17.273 18.51 19.2431 19.492

Gtop At day 28 Mpa 0.8114 0.5966 0.408 -0.542 -0.528 -0.8364 -4.605 -6.60118 -6.9223
Girder Gbottom Mpa 9.8551 10.082 10.281 14.842 22.173 22.504 26.61 28.939 29.439

Gtop 28 To day 35 Mpa 0.7486 0.5387 0.3542 -0.573 -0.546 -0.8449 -4.501 -6.42803 -6.738
Girder Gbottom Mpa 9.7739 9.9946 10.188 14.639 21.73 22.047 25.96 28.163 28.64

Girder Gtop 35 To day 63 Mpa 0.7492 0.5418 0.3597 -0.549 -0.509 -0.8033 -4.408 -6.32014 -6.6311
Gbottom Mpa 9.6184 9.8369 10.028 14.39 21.301 21.614 25.53 27.7469 28.238

Girder Gtop 63 To day 64 Mpa 0.7491 0.5417 0.3597 -0.548 -0.508 -0.8022 -4.405 -6.31669 -6.6276
Gbottom Mpa 9.6147 9.8331 10.025 14.384 21.29 21.603 25.51 27.7332 28.224

Girder Gtop 64 To day 92 Mpa 0.7533 0.5473 0.3666 -0.53 -0.482 -0.7734 -4.349 -6.25093 -6.5622
Gbottom Mpa 9.5277 9.7449 9.9351 14.245 21.051 21.362 25.26 27.4856 27.983

Gtop 92 To day 36500 Mpa 0.7963 0.6113 0.4494 -0.305 -0.181 -0.4358 -3.577 -5.25302 -5.5213
Girder Gbottom Mpa 8.3259 8.5203 8.6899 12.346 17.884 18.153 21.57 23.5143 23.931

RARE LOAD COMBINATIONS :


1) Rare Combination LC-SR1 : At the time of 1st stage prestress, just after ES loss of Stage -I cables
Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop At day 14 Mpa -3.243 -3.308 -3.364 -3.985 -4.082 -4.1757 -5.322 -5.94329 -6.0773
Girder Gbottom Mpa 10.272 10.342 10.403 13.332 18.208 18.312 19.62 20.4076 20.684

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.788 5.95593 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.8538 -4.808 -5.98034 -6.3712

Total Stresses (A+B)


Gtop Mpa -3.253 -3.195 -3.146 -2.681 -1.396 -1.3335 -0.533 0.01264 0.2679
Girder Gbottom Mpa 10.282 10.226 10.179 12.005 15.51 15.458 14.82 14.4273 14.313

Max Compressive stress = 15.51 Mpa < 24 Mpa OK


Max Tensile Stress = -3.253 Mpa >= -3.516 Mpa OK

2) Rare Combination LC-SR2 : At day 28 Just before II Stage prestressing


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop At day 0 Mpa -3.104 -3.166 -3.22 -3.794 -3.851 -3.9386 -5.018 -5.60414 -5.7269
Girder Gbottom Mpa 9.8312 9.8978 9.9563 12.693 17.175 17.273 18.51 19.2431 19.492

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.788 5.95593 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.8538 -4.808 -5.98034 -6.3712

EPC Contractor-M/s Krishna Constructions 99


Design ch-109+720
Design of PSC Girder

Total Stresses (A+B)


Gtop Mpa -3.113 -3.053 -3.002 -2.49 -1.164 -1.0965 -0.23 0.35179 0.6182
Girder Gbottom Mpa 9.841 9.7815 9.7317 11.366 14.477 14.419 13.7 13.2627 13.121

Max Compressive stress = 14.477 Mpa < 24 Mpa OK


Max Tensile Stress = -3.113 Mpa >= -3.516 Mpa OK

3) Rare Combination LC-SR3 : At day 28 Just after II Stage prestressing after ES


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.8114 0.5966 0.408 -0.542 -0.528 -0.8364 -4.605 -6.60118 -6.9223
Girder Gbottom Mpa 9.8551 10.082 10.281 14.842 22.173 22.504 26.61 28.939 29.439

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.788 5.95593 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.8538 -4.808 -5.98034 -6.3712

Total Stresses (A+B)


Gtop Mpa 0.8019 0.7095 0.6259 0.762 2.1583 2.0058 0.183 -0.64525 -0.5771
Girder Gbottom Mpa 9.8649 9.9653 10.056 13.515 19.476 19.65 21.8 22.9586 23.068

Max Compressive stress = 23.068 Mpa < 24 Mpa OK


Max Tensile Stress = -0.645 Mpa >= -3.516 Mpa OK

4) Rare Combination LC-SR4 : At day 35 At the time of casting of deck slab


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.7486 0.5387 0.3542 -0.573 -0.546 -0.8449 -4.501 -6.42803 -6.738
Girder Gbottom Mpa 9.7739 9.9946 10.188 14.639 21.73 22.047 25.96 28.163 28.64

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.788 5.95593 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.8538 -4.808 -5.98034 -6.3712

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.491 4.45644 4.7698
Girder Gbottom Mpa 0.0017 -0.098 -0.164 -0.88 -1.851 -1.9424 -3.505 -4.4747 -4.7893
Total Stresses (A+B +C)
Gtop Mpa 0.7375 0.7469 0.7312 1.596 3.9847 3.9318 3.779 3.98434 4.3769
Girder Gbottom Mpa 9.7854 9.7798 9.7996 12.432 17.182 17.251 17.65 17.7079 17.479

Max Compressive stress = 17.708 Mpa < 24 Mpa OK


Max Tensile Stress = 0.7312 Mpa >= -3.516 Mpa OK

5) Rare Combination LC-SR5 : At day 63 At the time of transfer over permanent bearings
Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.7492 0.5418 0.3597 -0.549 -0.509 -0.8033 -4.408 -6.32014 -6.6311
Girder Gbottom Mpa 9.6184 9.8369 10.028 14.39 21.301 21.614 25.53 27.7469 28.238

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.788 5.95593 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.8538 -4.808 -5.98034 -6.3712

EPC Contractor-M/s Krishna Constructions 100


Design ch-109+720
Design of PSC Girder

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.491 4.45644 4.7698
Girder Gbottom Mpa 0.0017 -0.098 -0.164 -0.88 -1.851 -1.9424 -3.505 -4.4747 -4.7893

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to differencial shrinkage Load factor = 1
Dtop Mpa -0.182 -0.182 -0.182 -0.162 -0.122 -0.1219 -0.122 -0.12189 -0.1219
Deck Dbottom Mpa -0.224 -0.224 -0.224 -0.205 -0.167 -0.1668 -0.167 -0.16685 -0.1668
Gtop Mpa 0.2822 0.2822 0.2822 0.3008 0.3393 0.3393 0.339 0.33932 0.3393
Girder Gbottom Mpa -0.151 -0.151 -0.151 -0.148 -0.131 -0.1307 -0.131 -0.1307 -0.1307
Total Stresses (A+B +C+D+E)
Dtop Mpa -0.182 -0.182 -0.182 -0.162 -0.122 -0.1219 -0.122 -0.12189 -0.1219
Deck Dbottom Mpa -0.224 -0.224 -0.224 -0.205 -0.167 -0.1668 -0.167 -0.16685 -0.1668
Gtop Mpa 1.0203 1.0322 1.0189 1.9211 4.3603 4.3127 4.211 4.43156 4.8231
Girder Gbottom Mpa 9.4785 9.4708 9.4883 12.035 16.622 16.687 17.08 17.1612 16.946

Max Compressive stress = 17.161 Mpa < 24 Mpa OK


Max Tensile Stress = 1.0189 Mpa >= -3.516 Mpa OK

6) Rare Combination LC-SR6 : At day 64 At the time of placing of SIDL


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.7491 0.5417 0.3597 -0.548 -0.508 -0.8022 -4.405 -6.31669 -6.6276
Girder Gbottom Mpa 9.6147 9.8331 10.025 14.384 21.29 21.603 25.51 27.7332 28.224

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.788 5.95593 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.8538 -4.808 -5.98034 -6.3712

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.491 4.45644 4.7698
Girder Gbottom Mpa 0.0017 -0.098 -0.164 -0.88 -1.851 -1.9424 -3.505 -4.4747 -4.7893

D) Stresses due to transfer over permanent Load


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.1) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.2) Stresses due to placement of SurfacingLoad factor = 1
Dtop Mpa 0 0.0115 0.0211 0.1118 0.2074 0.2199 0.376 0.46944 0.4999
Deck Dbottom Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.283 0.35378 0.3767
Gtop Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.283 0.35378 0.3767
Girder Gbottom Mpa 0 -0.016 -0.029 -0.175 -0.378 -0.4007 -0.685 -0.8554 -0.9108

F) Stresses due to Differential shrinkage Load factor = 1


Dtop Mpa -0.182 -0.182 -0.182 -0.162 -0.122 -0.1218 -0.122 -0.12184 -0.1218
Deck Dbottom Mpa -0.224 -0.224 -0.224 -0.205 -0.167 -0.1668 -0.167 -0.16678 -0.1668
Gtop Mpa 0.2821 0.2821 0.2821 0.3007 0.3392 0.3392 0.339 0.33918 0.3392
Girder Gbottom Mpa -0.151 -0.151 -0.151 -0.148 -0.131 -0.1306 -0.131 -0.13065 -0.1306

EPC Contractor-M/s Krishna Constructions 101


Design ch-109+720
Design of PSC Girder

G) Stresses due to wind Load factor = 0.6


Dtop Mpa 0 0.0068 0.0125 0.066 0.1225 0.1299 0.222 0.27733 0.2953
Deck Dbottom Mpa 0 0.0054 0.0099 0.0512 0.0923 0.0979 0.167 0.209 0.2226
Gtop Mpa 0 0.0054 0.0099 0.0512 0.0923 0.0979 0.167 0.209 0.2226
Girder Gbottom Mpa 0 -0.009 -0.017 -0.104 -0.223 -0.2367 -0.405 -0.50534 -0.5381
Total Stresses (A+B +C+D+E+F)
Dtop Mpa -0.182 -0.171 -0.161 -0.051 0.0855 0.0981 0.254 0.3476 0.378
Deck Dbottom Mpa -0.224 -0.215 -0.207 -0.119 -0.01 -0.0011 0.117 0.187 0.2099
Gtop Mpa 1.0201 1.0412 1.0356 2.0082 4.5174 4.4793 4.497 4.78864 5.2032
Girder Gbottom Mpa 9.4749 9.4515 9.4558 11.853 16.233 16.275 16.39 16.2921 16.022
Total Stresses (A+B +C+D+E+F+G) wind downward
Dtop Mpa -0.182 -0.164 -0.149 0.0154 0.2081 0.228 0.476 0.62493 0.6733
Deck Dbottom Mpa -0.224 -0.209 -0.197 -0.067 0.0818 0.0968 0.284 0.396 0.4325
Gtop Mpa 1.0201 1.0466 1.0455 2.0594 4.6098 4.5772 4.664 4.99764 5.4257
Girder Gbottom Mpa 9.4749 9.4423 9.4388 11.749 16.009 16.039 15.98 15.7868 15.484
Total Stresses (A+B +C+D+E+F+G) wind upward
Dtop Mpa -0.182 -0.178 -0.174 -0.117 -0.037 -0.0318 0.032 0.07027 0.0827
Deck Dbottom Mpa -0.224 -0.22 -0.217 -0.17 -0.103 -0.099 -0.051 -0.022 -0.0126
Gtop Mpa 1.0201 1.0358 1.0257 1.957 4.4251 4.3814 4.33 4.57964 4.9806
Girder Gbottom Mpa 9.4749 9.4607 9.4728 11.957 16.456 16.512 16.79 16.7975 16.56

Max Compressive stress = 16.385 Mpa < 24 Mpa OK


Max Tensile Stress = 1.0201 Mpa >= -3.516 Mpa OK

Max Compressive stress (wind downward) = 16.039 Mpa < 24 Mpa OK


Max Tensile Stress (wind downward) = 1.0201 Mpa >= -3.516 Mpa OK

Max Compressive stress (wind upward) = 16.797 Mpa < 24 Mpa OK


Max Tensile Stress (wind upward) = 1.0201 Mpa >= -3.516 Mpa OK

7) Rare Combination LC-SR7 : At day 92 Structure open to LL


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.7533 0.5473 0.3666 -0.53 -0.482 -0.7734 -4.349 -6.25093 -6.5622
Girder Gbottom Mpa 9.5277 9.7449 9.9351 14.245 21.051 21.362 25.26 27.4856 27.983

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.788 5.95593 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.8538 -4.808 -5.98034 -6.3712

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.491 4.45644 4.7698
Girder Gbottom Mpa 0.0017 -0.098 -0.164 -0.88 -1.851 -1.9424 -3.505 -4.4747 -4.7893

D) Stresses due to transfer over permanent


Load
bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0

EPC Contractor-M/s Krishna Constructions 102


Design ch-109+720
Design of PSC Girder

E) Stresses due to surfacing Load factor = 1


Dtop Mpa 0 0.0115 0.0211 0.1118 0.2074 0.2199 0.376 0.46944 0.4999
Deck Dbottom Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.283 0.35378 0.3767
Gtop Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.283 0.35378 0.3767
Girder Gbottom Mpa 0 -0.016 -0.029 -0.175 -0.378 -0.4007 -0.685 -0.8554 -0.9108
F) Stresses due to Live load (Without SV) Load factor = 1
Dtop Mpa 0 0.0753 0.1474 0.8233 1.5436 1.71 2.728 3.22632 3.528
Deck Dbottom Mpa 0 0.0598 0.117 0.6387 1.1633 1.2887 2.056 2.43142 2.6588
Gtop Mpa 0 0.0598 0.117 0.6387 1.1633 1.2887 2.056 2.43142 2.6588
Girder Gbottom Mpa 0 -0.102 -0.2 -1.292 -2.813 -3.1159 -4.971 -5.8789 -6.4286
F.1) Stresses due to Live load (With SV) Load factor = 1
Dtop Mpa 0 0.0489 0.0996 0.5692 1.0773 1.1492 2.032 2.6525 2.7433
Deck Dbottom Mpa 0 0.0388 0.0791 0.4416 0.8118 0.866 1.531 1.99897 2.0674
Gtop Mpa 0 0.0388 0.0791 0.4416 0.8118 0.866 1.531 1.99897 2.0674
Girder Gbottom Mpa 0 -0.067 -0.135 -0.893 -1.963 -2.094 -3.703 -4.8333 -4.9987
G) Stresses due to differential shrinkage Load factor = 1
Dtop Mpa -0.173 -0.173 -0.173 -0.154 -0.116 -0.1158 -0.116 -0.11579 -0.1158
Deck Dbottom Mpa -0.213 -0.213 -0.213 -0.195 -0.158 -0.1585 -0.158 -0.15849 -0.1585
Gtop Mpa 0.2681 0.2681 0.2681 0.2857 0.3223 0.3223 0.322 0.32233 0.3223
Girder Gbottom Mpa -0.144 -0.144 -0.144 -0.141 -0.124 -0.1242 -0.124 -0.12416 -0.1242
G) Stresses due to wind Load factor = 0.6
Dtop Mpa 0 0.0068 0.0125 0.066 0.1225 0.1299 0.222 0.27733 0.2953
Deck Dbottom Mpa 0 0.0054 0.0099 0.0512 0.0923 0.0979 0.167 0.209 0.2226
Gtop Mpa 0 0.0054 0.0099 0.0512 0.0923 0.0979 0.167 0.209 0.2226
Girder Gbottom Mpa 0 -0.009 -0.017 -0.104 -0.223 -0.2367 -0.405 -0.50534 -0.5381
Total Stresses (A+B +C+D+E+F+G) (Without SV Loading)
Dtop Mpa -0.173 -0.087 -0.005 0.7808 1.6352 1.8141 2.988 3.57998 3.9121
Deck Dbottom Mpa -0.213 -0.144 -0.079 0.5303 1.1611 1.2959 2.181 2.62671 2.877
Gtop Mpa 1.0103 1.0926 1.1455 2.65 5.6901 5.78 6.592 7.26898 7.9106
Girder Gbottom Mpa 9.3954 9.2684 9.1735 10.43 13.188 12.926 11.17 10.1721 9.3585
Total Stresses (A+B +C+D+E+F+G) (With SV Loading)
Dtop Mpa -0.173 -0.113 -0.053 0.5267 1.1689 1.2533 2.292 3.00615 3.1274
Deck Dbottom Mpa -0.213 -0.165 -0.117 0.3332 0.8096 0.8733 1.656 2.19426 2.2856
Gtop Mpa 1.0103 1.0717 1.1076 2.4529 5.3386 5.3573 6.068 6.83653 7.3192
Girder Gbottom Mpa 9.3954 9.3042 9.2384 10.829 14.038 13.947 12.44 11.2177 10.788
Total Stresses (A+B +C+D+E+F+G) wind downward
Dtop Mpa -0.173 -0.08 0.0077 0.8468 1.7577 1.944 3.21 3.85731 4.2074
Deck Dbottom Mpa -0.213 -0.138 -0.069 0.5815 1.2534 1.3938 2.348 2.83571 3.0996
Gtop Mpa 1.0103 1.0979 1.1554 2.7012 5.7824 5.8779 6.759 7.47798 8.1331
Girder Gbottom Mpa 9.3954 9.2592 9.1565 10.326 12.965 12.689 10.77 9.66674 8.8204
Total Stresses (A+B +C+D+E+F+G) wind upward
Dtop Mpa -0.173 -0.093 -0.017 0.7148 1.5127 1.6842 2.766 3.30264 3.6168
Deck Dbottom Mpa -0.213 -0.149 -0.089 0.479 1.0688 1.198 2.013 2.4177 2.6544
Gtop Mpa 1.0103 1.0872 1.1356 2.5988 5.5978 5.6821 6.425 7.05997 7.688
Girder Gbottom Mpa 9.3954 9.2777 9.1905 10.534 13.411 13.162 11.57 10.6774 9.8966
Max Compressive stress = 14.038 Mpa < 24 Mpa OK
Max Tensile Stress = 1.0103 Mpa >= -3.516 Mpa OK
Max Compressive stress (wind downward) = 12.965 Mpa < 24 Mpa OK
Max Tensile Stress (wind downward) = 1.0103 Mpa >= -3.516 Mpa OK
Max Compressive stress (wind upward) = 13.411 Mpa < 24 Mpa OK
Max Tensile Stress (wind upward) = 1.0103 Mpa >= -3.516 Mpa OK

EPC Contractor-M/s Krishna Constructions 103


Design ch-109+720
Design of PSC Girder

7.1) Rare Combination LC-SR7.1 : At day 92 Structure open to LL + temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.7533 0.5473 0.3666 -0.53 -0.482 -0.7734 -4.349 -6.25093 -6.5622
Girder Gbottom Mpa 9.5277 9.7449 9.9351 14.245 21.051 21.362 25.26 27.4856 27.983

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.788 5.95593 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.8538 -4.808 -5.98034 -6.3712

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.491 4.45644 4.7698
Girder Gbottom Mpa 0.0017 -0.098 -0.164 -0.88 -1.851 -1.9424 -3.505 -4.4747 -4.7893

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0115 0.0211 0.1118 0.2074 0.2199 0.376 0.46944 0.4999
Deck Dbottom Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.283 0.35378 0.3767
Gtop Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.283 0.35378 0.3767
Girder Gbottom Mpa 0 -0.016 -0.029 -0.175 -0.378 -0.4007 -0.685 -0.8554 -0.9108
F) Stresses due to Live load (Without SV) Load factor = 1
Dtop Mpa 0 0.0753 0.1474 0.8233 1.5436 1.71 2.728 3.22632 3.528
Deck Dbottom Mpa 0 0.0598 0.117 0.6387 1.1633 1.2887 2.056 2.43142 2.6588
Gtop Mpa 0 0.0598 0.117 0.6387 1.1633 1.2887 2.056 2.43142 2.6588
Girder Gbottom Mpa 0 -0.102 -0.2 -1.292 -2.813 -3.1159 -4.971 -5.8789 -6.4286
F.1) Stresses due to Live load (With SV) Load factor = 1
Dtop Mpa 0 0.0489 0.0996 0.5692 1.0773 1.1492 2.032 2.6525 2.7433
Deck Dbottom Mpa 0 0.0388 0.0791 0.4416 0.8118 0.866 1.531 1.99897 2.0674
Gtop Mpa 0 0.0388 0.0791 0.4416 0.8118 0.866 1.531 1.99897 2.0674
Girder Gbottom Mpa 0 -0.067 -0.135 -0.893 -1.963 -2.094 -3.703 -4.8333 -4.9987
G) Stresses due to differential shrinkage Load factor = 1
Dtop Mpa -0.173 -0.173 -0.173 -0.154 -0.116 -0.1158 -0.116 -0.11579 -0.1158
Deck Dbottom Mpa -0.213 -0.213 -0.213 -0.195 -0.158 -0.1585 -0.158 -0.15849 -0.1585
Gtop Mpa 0.2681 0.2681 0.2681 0.2857 0.3223 0.3223 0.322 0.32233 0.3223
Girder Gbottom Mpa -0.144 -0.144 -0.144 -0.141 -0.124 -0.1242 -0.124 -0.12416 -0.1242

H) +ve temperature stresses Load factor = 0.6


Dtop Mpa 2.712 2.712 2.712 2.8197 2.9285 2.9285 2.928 2.92848 2.9285
Deck Dbottom Mpa -0.792 -0.792 -0.792 -0.718 -0.643 -0.6427 -0.643 -0.64273 -0.6427
Gtop Mpa -0.792 -0.792 -0.792 -0.718 -0.643 -0.6427 -0.643 -0.64273 -0.6427
Girder Gbottom Mpa 1.6835 1.6835 1.6835 1.4091 1.1323 1.1323 1.132 1.1323 1.1323
Total Stresses (A+B +C+D+E+F+G+H) (Without SV)
Dtop Mpa 2.5387 2.6254 2.7072 3.6005 4.5637 4.7426 5.916 6.50846 6.8406
Deck Dbottom Mpa -1.005 -0.936 -0.871 -0.187 0.5184 0.6532 1.538 1.98398 2.2343
Gtop Mpa 0.2184 0.3007 0.3536 1.9324 5.0473 5.1372 5.949 6.62624 7.2679
Girder Gbottom Mpa 11.079 10.952 10.857 11.839 14.32 14.058 12.3 11.3044 10.491

EPC Contractor-M/s Krishna Constructions 104


Design ch-109+720
Design of PSC Girder

Total Stresses (A+B +C+D+E+F+G+H) (With SV Loading)


Dtop Mpa -0.173 -0.113 -0.053 0.5267 1.1689 1.2533 2.292 3.00615 3.1274
Deck Dbottom Mpa -0.213 -0.165 -0.117 0.3332 0.8096 0.8733 1.656 2.19426 2.2856
Gtop Mpa 1.0103 1.0717 1.1076 2.4529 5.3386 5.3573 6.068 6.83653 7.3192
Girder Gbottom Mpa 9.3954 9.3042 9.2384 10.829 14.038 13.947 12.44 11.2177 10.788

Max Compressive stress = 14.32 Mpa < 24 Mpa OK


Max Tensile Stress = 0.2184 Mpa >= -3.516 Mpa OK

7.2) Rare Combination LC-SR7.2 : At day 92 Structure open to LL - temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.7533 0.5473 0.3666 -0.53 -0.482 -0.7734 -4.349 -6.25093 -6.5622
Girder Gbottom Mpa 9.5277 9.7449 9.9351 14.245 21.051 21.362 25.26 27.4856 27.983

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.788 5.95593 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.8538 -4.808 -5.98034 -6.3712

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.491 4.45644 4.7698
Girder Gbottom Mpa 0.0017 -0.098 -0.164 -0.88 -1.851 -1.9424 -3.505 -4.4747 -4.7893

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0115 0.0211 0.1118 0.2074 0.2199 0.376 0.46944 0.4999
Deck Dbottom Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.283 0.35378 0.3767
Gtop Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.283 0.35378 0.3767
Girder Gbottom Mpa 0 -0.016 -0.029 -0.175 -0.378 -0.4007 -0.685 -0.8554 -0.9108
F) Stresses due to Live load (Without SV) Load factor = 1
Dtop Mpa 0 0.0753 0.1474 0.8233 1.5436 1.71 2.728 3.22632 3.528
Deck Dbottom Mpa 0 0.0598 0.117 0.6387 1.1633 1.2887 2.056 2.43142 2.6588
Gtop Mpa 0 0.0598 0.117 0.6387 1.1633 1.2887 2.056 2.43142 2.6588
Girder Gbottom Mpa 0 -0.102 -0.2 -1.292 -2.813 -3.1159 -4.971 -5.8789 -6.4286
F.1) Stresses due to Live load (With SV) Load factor = 1
Dtop Mpa 0 0.0489 0.0996 0.5692 1.0773 1.1492 2.032 2.6525 2.7433
Deck Dbottom Mpa 0 0.0388 0.0791 0.4416 0.8118 0.866 1.531 1.99897 2.0674
Gtop Mpa 0 0.0388 0.0791 0.4416 0.8118 0.866 1.531 1.99897 2.0674
Girder Gbottom Mpa 0 -0.067 -0.135 -0.893 -1.963 -2.094 -3.703 -4.8333 -4.9987

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.173 -0.173 -0.173 -0.154 -0.116 -0.1158 -0.116 -0.11579 -0.1158
Deck Dbottom Mpa -0.213 -0.213 -0.213 -0.195 -0.158 -0.1585 -0.158 -0.15849 -0.1585
Gtop Mpa 0.2681 0.2681 0.2681 0.2857 0.3223 0.3223 0.322 0.32233 0.3223
Girder Gbottom Mpa -0.144 -0.144 -0.144 -0.141 -0.124 -0.1242 -0.124 -0.12416 -0.1242

EPC Contractor-M/s Krishna Constructions 105


Design ch-109+720
Design of PSC Girder

H) -ve temperature stresses Load factor = 0.6


Dtop Mpa -1.699 -1.699 -1.699 -1.643 -1.588 -1.5877 -1.588 -1.58772 -1.5877
Deck Dbottom Mpa 0.3901 0.3901 0.3901 0.4567 0.524 0.524 0.524 0.52397 0.524
Gtop Mpa 0.3901 0.3901 0.3901 0.4567 0.524 0.524 0.524 0.52397 0.524
Girder Gbottom Mpa -1.907 -1.907 -1.907 -1.724 -1.538 -1.5383 -1.538 -1.53827 -1.5383
Total Stresses (A+B +C+D+E+F+G+H) (Without SV)
Dtop Mpa -1.872 -1.785 -1.703 -0.863 0.0475 0.2264 1.4 1.99226 2.3244
Deck Dbottom Mpa 0.1774 0.2463 0.3112 0.987 1.6851 1.8199 2.705 3.15068 3.401
Gtop Mpa 1.4004 1.4827 1.5356 3.1067 6.2141 6.3039 7.116 7.79295 8.4346
Girder Gbottom Mpa 7.4881 7.3611 7.2662 8.7063 11.65 11.387 9.632 8.63382 7.8202
Total Stresses (A+B +C+D+E+F+G+H) (With SV Loading)
Dtop Mpa -0.173 -0.113 -0.053 0.5267 1.1689 1.2533 2.292 3.00615 3.1274
Deck Dbottom Mpa -0.213 -0.165 -0.117 0.3332 0.8096 0.8733 1.656 2.19426 2.2856
Gtop Mpa 1.0103 1.0717 1.1076 2.4529 5.3386 5.3573 6.068 6.83653 7.3192
Girder Gbottom Mpa 9.3954 9.3042 9.2384 10.829 14.038 13.947 12.44 11.2177 10.788

Max Compressive stress = 14.038 Mpa < 24 Mpa OK


Max Tensile Stress = 1.0103 Mpa >= -3.516 Mpa OK

7.3) Rare Combination LC-SR7.3 : At day 92 Structure open to LL + temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.7533 0.5473 0.3666 -0.53 -0.482 -0.7734 -4.349 -6.25093 -6.5622
Girder Gbottom Mpa 9.5277 9.7449 9.9351 14.245 21.051 21.362 25.26 27.4856 27.983

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.788 5.95593 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.8538 -4.808 -5.98034 -6.3712

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.491 4.45644 4.7698
Girder Gbottom Mpa 0.0017 -0.098 -0.164 -0.88 -1.851 -1.9424 -3.505 -4.4747 -4.7893

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0115 0.0211 0.1118 0.2074 0.2199 0.376 0.46944 0.4999
Deck Dbottom Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.283 0.35378 0.3767
Gtop Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.283 0.35378 0.3767
Girder Gbottom Mpa 0 -0.016 -0.029 -0.175 -0.378 -0.4007 -0.685 -0.8554 -0.9108
F) Stresses due to Live load (Without SV) Load factor = 0.75
Dtop Mpa 0 0.0564 0.1105 0.6175 1.1577 1.2825 2.046 2.41974 2.646
Deck Dbottom Mpa 0 0.0448 0.0878 0.479 0.8725 0.9665 1.542 1.82356 1.9941
Gtop Mpa 0 0.0448 0.0878 0.479 0.8725 0.9665 1.542 1.82356 1.9941
Girder Gbottom Mpa 0 -0.077 -0.15 -0.969 -2.11 -2.3369 -3.728 -4.40917 -4.8215

EPC Contractor-M/s Krishna Constructions 106


Design ch-109+720
Design of PSC Girder

F.1) Stresses due to Live load (With SV) Load factor = 0.75
Dtop Mpa 0 0.0367 0.0747 0.4269 0.8079 0.8619 1.524 1.98937 2.0575
Deck Dbottom Mpa 0 0.0291 0.0593 0.3312 0.6089 0.6495 1.149 1.49923 1.5505
Gtop Mpa 0 0.0291 0.0593 0.3312 0.6089 0.6495 1.149 1.49923 1.5505
Girder Gbottom Mpa 0 -0.05 -0.102 -0.67 -1.472 -1.5705 -2.777 -3.62497 -3.749

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.173 -0.173 -0.173 -0.154 -0.116 -0.1158 -0.116 -0.11579 -0.1158
Deck Dbottom Mpa -0.213 -0.213 -0.213 -0.195 -0.158 -0.1585 -0.158 -0.15849 -0.1585
Gtop Mpa 0.2681 0.2681 0.2681 0.2857 0.3223 0.3223 0.322 0.32233 0.3223
Girder Gbottom Mpa -0.144 -0.144 -0.144 -0.141 -0.124 -0.1242 -0.124 -0.12416 -0.1242
H) +ve temperature stresses Load factor = 1
Dtop Mpa 4.52 4.52 4.52 4.6996 4.8808 4.8808 4.881 4.8808 4.8808
Deck Dbottom Mpa -1.32 -1.32 -1.32 -1.196 -1.071 -1.0712 -1.071 -1.07122 -1.0712
Gtop Mpa -1.32 -1.32 -1.32 -1.196 -1.071 -1.0712 -1.071 -1.07122 -1.0712
Girder Gbottom Mpa 2.8058 2.8058 2.8058 2.3486 1.8872 1.8872 1.887 1.88716 1.8872
Total Stresses (A+B +C+D+E+F+G+H) (Without SV)
Dtop Mpa 4.3466 4.4146 4.4783 5.2745 6.1301 6.2674 7.187 7.6542 7.9109
Deck Dbottom Mpa -1.533 -1.479 -1.428 -0.825 -0.201 -0.0975 0.595 0.94763 1.1411
Gtop Mpa -0.31 -0.242 -0.204 1.2943 4.328 4.3866 5.007 5.5899 6.1747
Girder Gbottom Mpa 12.201 12.1 12.029 13.101 15.778 15.592 14.3 13.529 12.853
Total Stresses (A+B +C+D+E+F+G+H) (With SV Loading)
Dtop Mpa -0.173 -0.125 -0.077 0.3844 0.8995 0.966 1.784 2.34303 2.4415
Deck Dbottom Mpa -0.213 -0.174 -0.137 0.2228 0.6067 0.6568 1.273 1.69452 1.7688
Gtop Mpa 1.0103 1.0619 1.0878 2.3425 5.1357 5.1408 5.685 6.33679 6.8024
Girder Gbottom Mpa 9.3954 9.3209 9.2723 11.052 14.528 14.471 13.36 12.426 12.038

Max Compressive stress = 15.778 Mpa < 24 Mpa OK


Max Tensile Stress = -0.31 Mpa >= -3.516 Mpa OK

7.4) Rare Combination LC-SR7.4 : At day 92 Structure open to LL - temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.7533 0.5473 0.3666 -0.53 -0.482 -0.7734 -4.349 -6.25093 -6.5622
Girder Gbottom Mpa 9.5277 9.7449 9.9351 14.245 21.051 21.362 25.26 27.4856 27.983

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.788 5.95593 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.8538 -4.808 -5.98034 -6.3712

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.491 4.45644 4.7698
Girder Gbottom Mpa 0.0017 -0.098 -0.164 -0.88 -1.851 -1.9424 -3.505 -4.4747 -4.7893

D) Stresses due to transfer over permanent


Load
bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0

EPC Contractor-M/s Krishna Constructions 107


Design ch-109+720
Design of PSC Girder

E) Stresses due to surfacing Load factor = 1


Dtop Mpa 0 0.0115 0.0211 0.1118 0.2074 0.2199 0.376 0.46944 0.4999
Deck Dbottom Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.283 0.35378 0.3767
Gtop Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.283 0.35378 0.3767
Girder Gbottom Mpa 0 -0.016 -0.029 -0.175 -0.378 -0.4007 -0.685 -0.8554 -0.9108
F) Stresses due to Live load (Without SV) Load factor = 0.75
Dtop Mpa 0 0.0564 0.1105 0.6175 1.1577 1.2825 2.046 2.41974 2.646
Deck Dbottom Mpa 0 0.0448 0.0878 0.479 0.8725 0.9665 1.542 1.82356 1.9941
Gtop Mpa 0 0.0448 0.0878 0.479 0.8725 0.9665 1.542 1.82356 1.9941
Girder Gbottom Mpa 0 -0.077 -0.15 -0.969 -2.11 -2.3369 -3.728 -4.40917 -4.8215
F.1) Stresses due to Live load (With SV) Load factor = 0.75
Dtop Mpa 0 0.0367 0.0747 0.4269 0.8079 0.8619 1.524 1.98937 2.0575
Deck Dbottom Mpa 0 0.0291 0.0593 0.3312 0.6089 0.6495 1.149 1.49923 1.5505
Gtop Mpa 0 0.0291 0.0593 0.3312 0.6089 0.6495 1.149 1.49923 1.5505
Girder Gbottom Mpa 0 -0.05 -0.102 -0.67 -1.472 -1.5705 -2.777 -3.62497 -3.749

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.173 -0.173 -0.173 -0.154 -0.116 -0.1158 -0.116 -0.11579 -0.1158
Deck Dbottom Mpa -0.213 -0.213 -0.213 -0.195 -0.158 -0.1585 -0.158 -0.15849 -0.1585
Gtop Mpa 0.2681 0.2681 0.2681 0.2857 0.3223 0.3223 0.322 0.32233 0.3223
Girder Gbottom Mpa -0.144 -0.144 -0.144 -0.141 -0.124 -0.1242 -0.124 -0.12416 -0.1242
H) -ve temperature stresses Load factor = 1
Dtop Mpa -2.831 -2.831 -2.831 -2.739 -2.646 -2.6462 -2.646 -2.64619 -2.6462
Deck Dbottom Mpa 0.6502 0.6502 0.6502 0.7612 0.8733 0.8733 0.873 0.87329 0.8733
Gtop Mpa 0.6502 0.6502 0.6502 0.7612 0.8733 0.8733 0.873 0.87329 0.8733
Girder Gbottom Mpa -3.179 -3.179 -3.179 -2.873 -2.564 -2.5638 -2.564 -2.56378 -2.5638
Total Stresses (A+B +C+D+E+F+G+H) (Without SV)
Dtop Mpa -3.004 -2.936 -2.873 -2.164 -1.397 -1.2596 -0.34 0.1272 0.3839
Deck Dbottom Mpa 0.4375 0.4914 0.542 1.1318 1.7436 1.847 2.54 2.89214 3.0856
Gtop Mpa 1.6605 1.7278 1.7664 3.2516 6.2725 6.3311 6.951 7.53441 8.1192
Girder Gbottom Mpa 6.2166 6.1152 6.0448 7.8802 11.327 11.141 9.849 9.07803 8.4019
Total Stresses (A+B +C+D+E+F+G+H) (With SV Loading)
Dtop Mpa -0.173 -0.125 -0.077 0.3844 0.8995 0.966 1.784 2.34303 2.4415
Deck Dbottom Mpa -0.213 -0.174 -0.137 0.2228 0.6067 0.6568 1.273 1.69452 1.7688
Gtop Mpa 1.0103 1.0619 1.0878 2.3425 5.1357 5.1408 5.685 6.33679 6.8024
Girder Gbottom Mpa 9.3954 9.3209 9.2723 11.052 14.528 14.471 13.36 12.426 12.038

Max Compressive stress = 14.528 Mpa < 24 Mpa OK


Max Tensile Stress = 1.0103 Mpa >= -3.516 Mpa OK

8) Rare Combination LC-SR8 : At day 36500


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.7963 0.6113 0.4494 -0.305 -0.181 -0.4358 -3.577 -5.25302 -5.5213
Girder Gbottom Mpa 8.3259 8.5203 8.6899 12.346 17.884 18.153 21.57 23.5143 23.931

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.788 5.95593 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.8538 -4.808 -5.98034 -6.3712

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.491 4.45644 4.7698
Girder Gbottom Mpa 0.0017 -0.098 -0.164 -0.88 -1.851 -1.9424 -3.505 -4.4747 -4.7893

EPC Contractor-M/s Krishna Constructions 108


Design ch-109+720
Design of PSC Girder

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.1) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.2) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0115 0.0211 0.1118 0.2074 0.2199 0.376 0.46944 0.4999
Deck Dbottom Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.283 0.35378 0.3767
Gtop Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.283 0.35378 0.3767
Girder Gbottom Mpa 0 -0.016 -0.029 -0.175 -0.378 -0.4007 -0.685 -0.8554 -0.9108
F) Stresses due to Live load (Without SV) Load factor = 1
Dtop Mpa 0 0.0753 0.1474 0.8233 1.5436 1.71 2.728 3.22632 3.528
Deck Dbottom Mpa 0 0.0598 0.117 0.6387 1.1633 1.2887 2.056 2.43142 2.6588
Gtop Mpa 0 0.0598 0.117 0.6387 1.1633 1.2887 2.056 2.43142 2.6588
Girder Gbottom Mpa 0 -0.102 -0.2 -1.292 -2.813 -3.1159 -4.971 -5.8789 -6.4286
F.1) Stresses due to Live load (With SV) Load factor = 1
Dtop Mpa 0 0.0489 0.0996 0.5692 1.0773 1.1492 2.032 2.6525 2.7433
Deck Dbottom Mpa 0 0.0388 0.0791 0.4416 0.8118 0.866 1.531 1.99897 2.0674
Gtop Mpa 0 0.0388 0.0791 0.4416 0.8118 0.866 1.531 1.99897 2.0674
Girder Gbottom Mpa 0 -0.067 -0.135 -0.893 -1.963 -2.094 -3.703 -4.8333 -4.9987

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.713 -0.713 -0.713 -0.635 -0.477 -0.4765 -0.477 -0.47654 -0.4765
Deck Dbottom Mpa -0.875 -0.875 -0.875 -0.803 -0.652 -0.6523 -0.652 -0.65231 -0.6523
Gtop Mpa 1.1035 1.1035 1.1035 1.1759 1.3266 1.3266 1.327 1.32662 1.3266
Girder Gbottom Mpa -0.592 -0.592 -0.592 -0.58 -0.511 -0.511 -0.511 -0.511 -0.511
Total Stresses (A+B +C+D+E+F+G+H) (Without SV)
Dtop Mpa -0.713 -0.627 -0.545 0.3001 1.2745 1.4533 2.627 3.21923 3.5513
Deck Dbottom Mpa -0.875 -0.807 -0.742 -0.078 0.6673 0.8021 1.687 2.13289 2.3832
Gtop Mpa 1.8886 1.9919 2.0637 3.765 6.9956 7.1218 8.368 9.27117 9.9557
Girder Gbottom Mpa 7.7455 7.5958 7.4803 8.0913 9.6332 9.3292 7.093 5.81399 4.9203
Total Stresses (A+B +C+D+E+F+G+H) (With SV Loading)
Dtop Mpa 0 0.0604 0.1207 0.681 1.2846 1.3691 2.408 3.12194 3.2432
Deck Dbottom Mpa 0 0.048 0.0959 0.5283 0.9681 1.0318 1.815 2.35276 2.4441
Gtop Mpa 0.7851 0.8675 0.9223 2.392 5.3176 5.3726 6.517 7.51211 8.0377
Girder Gbottom Mpa 8.3374 8.2235 8.1371 9.0703 10.994 10.862 8.872 7.37059 6.8612

Max Compressive stress = 10.994 Mpa < 24 Mpa OK


Max Tensile Stress = 0.7851 Mpa >= -3.516 Mpa OK

8.1) Rare Combination LC-SR8.1 : At day 36500 + temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.7963 0.6113 0.4494 -0.305 -0.181 -0.4358 -3.577 -5.25302 -5.5213
Girder Gbottom Mpa 8.3259 8.5203 8.6899 12.346 17.884 18.153 21.57 23.5143 23.931

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.788 5.95593 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.8538 -4.808 -5.98034 -6.3712

EPC Contractor-M/s Krishna Constructions 109


Design ch-109+720
Design of PSC Girder

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.491 4.45644 4.7698
Girder Gbottom Mpa 0.0017 -0.098 -0.164 -0.88 -1.851 -1.9424 -3.505 -4.4747 -4.7893

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.1) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.2) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0115 0.0211 0.1118 0.2074 0.2199 0.376 0.46944 0.4999
Deck Dbottom Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.283 0.35378 0.3767
Gtop Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.283 0.35378 0.3767
Girder Gbottom Mpa 0 -0.016 -0.029 -0.175 -0.378 -0.4007 -0.685 -0.8554 -0.9108
F) Stresses due to Live load (Without SV) Load factor = 1
Dtop Mpa 0 0.0753 0.1474 0.8233 1.5436 1.71 2.728 3.22632 3.528
Deck Dbottom Mpa 0 0.0598 0.117 0.6387 1.1633 1.2887 2.056 2.43142 2.6588
Gtop Mpa 0 0.0598 0.117 0.6387 1.1633 1.2887 2.056 2.43142 2.6588
Girder Gbottom Mpa 0 -0.102 -0.2 -1.292 -2.813 -3.1159 -4.971 -5.8789 -6.4286
F.1) Stresses due to Live load (With SV) Load factor = 1
Dtop Mpa 0 0.0489 0.0996 0.5692 1.0773 1.1492 2.032 2.6525 2.7433
Deck Dbottom Mpa 0 0.0388 0.0791 0.4416 0.8118 0.866 1.531 1.99897 2.0674
Gtop Mpa 0 0.0388 0.0791 0.4416 0.8118 0.866 1.531 1.99897 2.0674
Girder Gbottom Mpa 0 -0.067 -0.135 -0.893 -1.963 -2.094 -3.703 -4.8333 -4.9987

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.713 -0.713 -0.713 -0.635 -0.477 -0.4765 -0.477 -0.47654 -0.4765
Deck Dbottom Mpa -0.875 -0.875 -0.875 -0.803 -0.652 -0.6523 -0.652 -0.65231 -0.6523
Gtop Mpa 1.1035 1.1035 1.1035 1.1759 1.3266 1.3266 1.327 1.32662 1.3266
Girder Gbottom Mpa -0.592 -0.592 -0.592 -0.58 -0.511 -0.511 -0.511 -0.511 -0.511

H) +ve temperature stresses Load factor = 0.6


Dtop Mpa 2.712 2.712 2.712 2.8197 2.9285 2.9285 2.928 2.92848 2.9285
Deck Dbottom Mpa -0.792 -0.792 -0.792 -0.718 -0.643 -0.6427 -0.643 -0.64273 -0.6427
Gtop Mpa -0.792 -0.792 -0.792 -0.718 -0.643 -0.6427 -0.643 -0.64273 -0.6427
Girder Gbottom Mpa 1.6835 1.6835 1.6835 1.4091 1.1323 1.1323 1.132 1.1323 1.1323
Total Stresses (A+B +C+D+E+F+G+H) (Without SV)
Dtop Mpa 1.9987 2.0854 2.1672 3.1198 4.2029 4.3818 5.556 6.14771 6.4798
Deck Dbottom Mpa -1.667 -1.598 -1.534 -0.795 0.0245 0.1594 1.044 1.49016 1.7405
Gtop Mpa 1.0967 1.2 1.2718 3.0474 6.3529 6.4791 7.725 8.62843 9.313
Girder Gbottom Mpa 9.429 9.2793 9.1637 9.5004 10.765 10.461 8.226 6.94628 6.0526
Total Stresses (A+B +C+D+E+F+G+H) (With SV Loading)
Dtop Mpa -0.713 -0.653 -0.593 0.046 0.8081 0.8925 1.931 2.6454 2.7666
Deck Dbottom Mpa -0.875 -0.828 -0.78 -0.275 0.3158 0.3794 1.162 1.70045 1.7918
Gtop Mpa 1.8886 1.971 2.0257 3.5679 6.6442 6.6992 7.844 8.83872 9.3643
Girder Gbottom Mpa 7.7455 7.6316 7.5452 8.49 10.483 10.351 8.361 6.85959 6.3502

Max Compressive stress = 10.765 Mpa < 24 Mpa OK


Max Tensile Stress = 1.0967 Mpa >= -3.516 Mpa OK

EPC Contractor-M/s Krishna Constructions 110


Design ch-109+720
Design of PSC Girder

8.2) Rare Combination LC-SR8.2 : At day 36500 - temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.7963 0.6113 0.4494 -0.305 -0.181 -0.4358 -3.577 -5.25302 -5.5213
Girder Gbottom Mpa 8.3259 8.5203 8.6899 12.346 17.884 18.153 21.57 23.5143 23.931

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.788 5.95593 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.8538 -4.808 -5.98034 -6.3712

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.491 4.45644 4.7698
Girder Gbottom Mpa 0.0017 -0.098 -0.164 -0.88 -1.851 -1.9424 -3.505 -4.4747 -4.7893

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.1) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.2) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0115 0.0211 0.1118 0.2074 0.2199 0.376 0.46944 0.4999
Deck Dbottom Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.283 0.35378 0.3767
Gtop Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.283 0.35378 0.3767
Girder Gbottom Mpa 0 -0.016 -0.029 -0.175 -0.378 -0.4007 -0.685 -0.8554 -0.9108
F) Stresses due to Live load (Without SV) Load factor = 1
Dtop Mpa 0 0.0753 0.1474 0.8233 1.5436 1.71 2.728 3.22632 3.528
Deck Dbottom Mpa 0 0.0598 0.117 0.6387 1.1633 1.2887 2.056 2.43142 2.6588
Gtop Mpa 0 0.0598 0.117 0.6387 1.1633 1.2887 2.056 2.43142 2.6588
Girder Gbottom Mpa 0 -0.102 -0.2 -1.292 -2.813 -3.1159 -4.971 -5.8789 -6.4286
F.1) Stresses due to Live load (With SV) Load factor = 1
Dtop Mpa 0 0.0489 0.0996 0.5692 1.0773 1.1492 2.032 2.6525 2.7433
Deck Dbottom Mpa 0 0.0388 0.0791 0.4416 0.8118 0.866 1.531 1.99897 2.0674
Gtop Mpa 0 0.0388 0.0791 0.4416 0.8118 0.866 1.531 1.99897 2.0674
Girder Gbottom Mpa 0 -0.067 -0.135 -0.893 -1.963 -2.094 -3.703 -4.8333 -4.9987

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.713 -0.713 -0.713 -0.635 -0.477 -0.4765 -0.477 -0.47654 -0.4765
Deck Dbottom Mpa -0.875 -0.875 -0.875 -0.803 -0.652 -0.6523 -0.652 -0.65231 -0.6523
Gtop Mpa 1.1035 1.1035 1.1035 1.1759 1.3266 1.3266 1.327 1.32662 1.3266
Girder Gbottom Mpa -0.592 -0.592 -0.592 -0.58 -0.511 -0.511 -0.511 -0.511 -0.511

H) -ve temperature stresses Load factor = 0.6


Dtop Mpa -1.699 -1.699 -1.699 -1.643 -1.588 -1.5877 -1.588 -1.58772 -1.5877
Deck Dbottom Mpa 0.3901 0.3901 0.3901 0.4567 0.524 0.524 0.524 0.52397 0.524
Gtop Mpa 0.3901 0.3901 0.3901 0.4567 0.524 0.524 0.524 0.52397 0.524
Girder Gbottom Mpa -1.907 -1.907 -1.907 -1.724 -1.538 -1.5383 -1.538 -1.53827 -1.5383
Total Stresses (A+B +C+D+E+F+G+H) (Without SV)
Dtop Mpa -2.412 -2.325 -2.243 -1.343 -0.313 -0.1344 1.039 1.63151 1.9636
Deck Dbottom Mpa -0.485 -0.416 -0.352 0.3791 1.1913 1.3261 2.211 2.65686 2.9072
Gtop Mpa 2.2787 2.382 2.4538 4.2218 7.5196 7.6458 8.892 9.79514 10.48
Girder Gbottom Mpa 5.8382 5.6885 5.573 6.3677 8.0949 7.7909 5.555 4.27572 3.3821

EPC Contractor-M/s Krishna Constructions 111


Design ch-109+720
Design of PSC Girder

Total Stresses (A+B +C+D+E+F+G+H) (With SV Loading)


Dtop Mpa -0.713 -0.653 -0.593 0.046 0.8081 0.8925 1.931 2.6454 2.7666
Deck Dbottom Mpa -0.875 -0.828 -0.78 -0.275 0.3158 0.3794 1.162 1.70045 1.7918
Gtop Mpa 1.8886 1.971 2.0257 3.5679 6.6442 6.6992 7.844 8.83872 9.3643
Girder Gbottom Mpa 7.7455 7.6316 7.5452 8.49 10.483 10.351 8.361 6.85959 6.3502

Max Compressive stress = 10.483 Mpa < 24 Mpa OK


Max Tensile Stress = 1.8886 Mpa >= -3.516 Mpa OK

8.3) Rare Combination LC-SR8.3 : At day 36500 + temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.7963 0.6113 0.4494 -0.305 -0.181 -0.4358 -3.577 -5.25302 -5.5213
Girder Gbottom Mpa 8.3259 8.5203 8.6899 12.346 17.884 18.153 21.57 23.5143 23.931

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.788 5.95593 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.8538 -4.808 -5.98034 -6.3712

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.491 4.45644 4.7698
Girder Gbottom Mpa 0.0017 -0.098 -0.164 -0.88 -1.851 -1.9424 -3.505 -4.4747 -4.7893

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.1) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.2) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0115 0.0211 0.1118 0.2074 0.2199 0.376 0.46944 0.4999
Deck Dbottom Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.283 0.35378 0.3767
Gtop Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.283 0.35378 0.3767
Girder Gbottom Mpa 0 -0.016 -0.029 -0.175 -0.378 -0.4007 -0.685 -0.8554 -0.9108
F) Stresses due to Live load (Without SV) Load factor = 0.75
Dtop Mpa 0 0.0564 0.1105 0.6175 1.1577 1.2825 2.046 2.41974 2.646
Deck Dbottom Mpa 0 0.0448 0.0878 0.479 0.8725 0.9665 1.542 1.82356 1.9941
Gtop Mpa 0 0.0448 0.0878 0.479 0.8725 0.9665 1.542 1.82356 1.9941
Girder Gbottom Mpa 0 -0.077 -0.15 -0.969 -2.11 -2.3369 -3.728 -4.40917 -4.8215
F.1) Stresses due to Live load (With SV) Load factor = 0.75
Dtop Mpa 0 0.0367 0.0747 0.4269 0.8079 0.8619 1.524 1.98937 2.0575
Deck Dbottom Mpa 0 0.0291 0.0593 0.3312 0.6089 0.6495 1.149 1.49923 1.5505
Gtop Mpa 0 0.0291 0.0593 0.3312 0.6089 0.6495 1.149 1.49923 1.5505
Girder Gbottom Mpa 0 -0.05 -0.102 -0.67 -1.472 -1.5705 -2.777 -3.62497 -3.749

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.713 -0.713 -0.713 -0.635 -0.477 -0.4765 -0.477 -0.47654 -0.4765
Deck Dbottom Mpa -0.875 -0.875 -0.875 -0.803 -0.652 -0.6523 -0.652 -0.65231 -0.6523
Gtop Mpa 1.1035 1.1035 1.1035 1.1759 1.3266 1.3266 1.327 1.32662 1.3266
Girder Gbottom Mpa -0.592 -0.592 -0.592 -0.58 -0.511 -0.511 -0.511 -0.511 -0.511

EPC Contractor-M/s Krishna Constructions 112


Design ch-109+720
Design of PSC Girder

H) +ve temperature stresses Load factor = 1


Dtop Mpa 4.52 4.52 4.52 4.6996 4.8808 4.8808 4.881 4.8808 4.8808
Deck Dbottom Mpa -1.32 -1.32 -1.32 -1.196 -1.071 -1.0712 -1.071 -1.07122 -1.0712
Gtop Mpa -1.32 -1.32 -1.32 -1.196 -1.071 -1.0712 -1.071 -1.07122 -1.0712
Girder Gbottom Mpa 2.8058 2.8058 2.8058 2.3486 1.8872 1.8872 1.887 1.88716 1.8872
Total Stresses (A+B +C+D+E+F+G+H) (Without SV)
Dtop Mpa 3.8067 3.8746 3.9383 4.7938 5.7694 5.9066 6.826 7.29345 7.5501
Deck Dbottom Mpa -2.195 -2.141 -2.091 -1.433 -0.695 -0.5913 0.102 0.45382 0.6473
Gtop Mpa 0.5688 0.6571 0.7146 2.4093 5.6336 5.7284 6.783 7.59209 8.2198
Girder Gbottom Mpa 10.551 10.427 10.336 10.763 12.224 11.995 10.22 9.17087 8.4147
Total Stresses (A+B +C+D+E+F+G+H) (With SV Loading)
Dtop Mpa -0.713 -0.665 -0.617 -0.096 0.5388 0.6052 1.423 1.98228 2.0808
Deck Dbottom Mpa -0.875 -0.837 -0.799 -0.385 0.1129 0.1629 0.78 1.2007 1.275
Gtop Mpa 1.8886 1.9613 2.006 3.4575 6.4412 6.4827 7.461 8.33898 8.8475
Girder Gbottom Mpa 7.7455 7.6483 7.5791 8.7133 10.974 10.875 9.287 8.06792 7.5999

Max Compressive stress = 12.224 Mpa < 24 Mpa OK


Max Tensile Stress = 0.5688 Mpa >= -3.516 Mpa OK

8.4) Rare Combination LC-SR8.4 : At day 36500 - temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.7963 0.6113 0.4494 -0.305 -0.181 -0.4358 -3.577 -5.25302 -5.5213
Girder Gbottom Mpa 8.3259 8.5203 8.6899 12.346 17.884 18.153 21.57 23.5143 23.931

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.788 5.95593 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.8538 -4.808 -5.98034 -6.3712

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.491 4.45644 4.7698
Girder Gbottom Mpa 0.0017 -0.098 -0.164 -0.88 -1.851 -1.9424 -3.505 -4.4747 -4.7893

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.1) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.2) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0115 0.0211 0.1118 0.2074 0.2199 0.376 0.46944 0.4999
Deck Dbottom Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.283 0.35378 0.3767
Gtop Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.283 0.35378 0.3767
Girder Gbottom Mpa 0 -0.016 -0.029 -0.175 -0.378 -0.4007 -0.685 -0.8554 -0.9108
F) Stresses due to Live load (Without SV) Load factor = 0.75
Dtop Mpa 0 0.0564 0.1105 0.6175 1.1577 1.2825 2.046 2.41974 2.646
Deck Dbottom Mpa 0 0.0448 0.0878 0.479 0.8725 0.9665 1.542 1.82356 1.9941
Gtop Mpa 0 0.0448 0.0878 0.479 0.8725 0.9665 1.542 1.82356 1.9941
Girder Gbottom Mpa 0 -0.077 -0.15 -0.969 -2.11 -2.3369 -3.728 -4.40917 -4.8215

EPC Contractor-M/s Krishna Constructions 113


Design ch-109+720
Design of PSC Girder

F.1) Stresses due to Live load (With SV) Load factor = 0.75
Dtop Mpa 0 0.0367 0.0747 0.4269 0.8079 0.8619 1.524 1.98937 2.0575
Deck Dbottom Mpa 0 0.0291 0.0593 0.3312 0.6089 0.6495 1.149 1.49923 1.5505
Gtop Mpa 0 0.0291 0.0593 0.3312 0.6089 0.6495 1.149 1.49923 1.5505
Girder Gbottom Mpa 0 -0.05 -0.102 -0.67 -1.472 -1.5705 -2.777 -3.62497 -3.749

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.713 -0.713 -0.713 -0.635 -0.477 -0.4765 -0.477 -0.47654 -0.4765
Deck Dbottom Mpa -0.875 -0.875 -0.875 -0.803 -0.652 -0.6523 -0.652 -0.65231 -0.6523
Gtop Mpa 1.1035 1.1035 1.1035 1.1759 1.3266 1.3266 1.327 1.32662 1.3266
Girder Gbottom Mpa -0.592 -0.592 -0.592 -0.58 -0.511 -0.511 -0.511 -0.511 -0.511

H) -ve temperature stresses Load factor = 1


Dtop Mpa -2.831 -2.831 -2.831 -2.739 -2.646 -2.6462 -2.646 -2.64619 -2.6462
Deck Dbottom Mpa 0.6502 0.6502 0.6502 0.7612 0.8733 0.8733 0.873 0.87329 0.8733
Gtop Mpa 0.6502 0.6502 0.6502 0.7612 0.8733 0.8733 0.873 0.87329 0.8733
Girder Gbottom Mpa -3.179 -3.179 -3.179 -2.873 -2.564 -2.5638 -2.564 -2.56378 -2.5638
Total Stresses (A+B +C+D+E+F+G)
Dtop Mpa -3.544 -3.476 -3.413 -2.645 -1.758 -1.6203 -0.701 -0.23355 0.0232
Deck Dbottom Mpa -0.225 -0.171 -0.121 0.5239 1.2497 1.3532 2.046 2.39832 2.5918
Gtop Mpa 2.5388 2.6271 2.6846 4.3666 7.5781 7.6729 8.727 9.5366 10.164
Girder Gbottom Mpa 4.5667 4.4426 4.3515 5.5416 7.7726 7.5444 5.772 4.71994 3.9637
Total Stresses (A+B +C+D+E+F+G)
Dtop Mpa -0.713 -0.665 -0.617 -0.096 0.5388 0.6052 1.423 1.98228 2.0808
Deck Dbottom Mpa -0.875 -0.837 -0.799 -0.385 0.1129 0.1629 0.78 1.2007 1.275
Gtop Mpa 1.8886 1.9613 2.006 3.4575 6.4412 6.4827 7.461 8.33898 8.8475
Girder Gbottom Mpa 7.7455 7.6483 7.5791 8.7133 10.974 10.875 9.287 8.06792 7.5999

Max Compressive stress = 10.974 Mpa < 24 Mpa OK


Max Tensile Stress = 1.8886 Mpa >= -3.516 Mpa OK

SUMMARY FOR SLS RARE COMBINATION


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
1) Rare Combination LC-SR1 : At the time of 1st stage prestress, just after ES loss of Stage -I cables
Total Stresses (A+B)
Gtop Mpa -3.253 -3.195 -3.146 -2.681 -1.396 -1.3335 -0.533 0.01264 0.2679
Girder Gbottom Mpa 10.282 10.226 10.179 12.005 15.51 15.458 14.82 14.4273 14.313
2) Rare Combination LC-SR2 At day 28 Just before II Stage prestressing
Total Stresses (A+B)
Gtop Mpa -3.113 -3.053 -3.002 -2.49 -1.164 -1.0965 -0.23 0.35179 0.6182
Girder Gbottom Mpa 9.841 9.7815 9.7317 11.366 14.477 14.419 13.7 13.2627 13.121
3) Rare Combination LC-SR3 : At day 28 Just after II Stage prestressing after ES
Total Stresses (A+B)
Gtop Mpa 0.8019 0.7095 0.6259 0.762 2.1583 2.0058 0.183 -0.64525 -0.5771
Girder Gbottom Mpa 9.8649 9.9653 10.056 13.515 19.476 19.65 21.8 22.9586 23.068
4) Rare Combination LC-SR4 : At day 35 At the time of casting of deck slab
Total Stresses (A+B)
Gtop Mpa 0.7375 0.7469 0.7312 1.596 3.9847 3.9318 3.779 3.98434 4.3769
Girder Gbottom Mpa 9.7854 9.7798 9.7996 12.432 17.182 17.251 17.65 17.7079 17.479
5) Rare Combination LC-SR5 : At day 63 At the time of transfer over permanent bearings
Total Stresses (A+B)
Gtop Mpa 1.0203 1.0322 1.0189 1.9211 4.3603 4.3127 4.211 4.43156 4.8231
Girder Gbottom Mpa 9.4785 9.4708 9.4883 12.035 16.622 16.687 17.08 17.1612 16.946
6) Rare Combination LC-SR6 : At day 64 At the time of placing of SIDL
Total Stresses (A+B)
Gtop Mpa 1.0201 1.0412 1.0356 2.0082 4.5174 4.4793 4.497 4.78864 5.2032
Girder Gbottom Mpa 9.4749 9.4515 9.4558 11.853 16.233 16.275 16.39 16.2921 16.022

EPC Contractor-M/s Krishna Constructions 114


Design ch-109+720
Design of PSC Girder

7) Rare Combination LC-SR7 : At day 92 Structure open to LL


Total Stresses (A+B)
Gtop Mpa 1.0103 1.0926 1.1455 2.65 5.6901 5.78 6.592 7.26898 7.9106
Girder Gbottom Mpa 9.3954 9.2684 9.1735 10.43 13.188 12.926 11.17 10.1721 9.3585
7.1) Rare Combination LC-SR7.1 : At day 92 Structure open to LL + temperature stresses
Total Stresses (A+B)
Gtop Mpa 0.2184 0.3007 0.3536 1.9324 5.0473 5.1372 5.949 6.62624 7.2679
Girder Gbottom Mpa 11.079 10.952 10.857 11.839 14.32 14.058 12.3 11.3044 10.491
7.2) Rare Combination LC-SR7.2 : At day 92 Structure open to LL - temperature stresses
Total Stresses (A+B)
Gtop Mpa 1.4004 1.4827 1.5356 3.1067 6.2141 6.3039 7.116 7.79295 8.4346
Girder Gbottom Mpa 7.4881 7.3611 7.2662 8.7063 11.65 11.387 9.632 8.63382 7.8202
7.3) Rare Combination LC-SR7.3 : At day 92 Structure open to LL + temperature stresses
Total Stresses (A+B)
Gtop Mpa -0.31 -0.242 -0.204 1.2943 4.328 4.3866 5.007 5.5899 6.1747
Girder Gbottom Mpa 12.201 12.1 12.029 13.101 15.778 15.592 14.3 13.529 12.853
7.4) Rare Combination LC-SR7.4 : At day 92 Structure open to LL - temperature stresses
Total Stresses (A+B)
Gtop Mpa 1.6605 1.7278 1.7664 3.2516 6.2725 6.3311 6.951 7.53441 8.1192
Girder Gbottom Mpa 6.2166 6.1152 6.0448 7.8802 11.327 11.141 9.849 9.07803 8.4019

Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
8) Rare Combination LC-SR8 : At day 36500
Total Stresses (A+B)
Gtop Mpa 1.8886 1.9919 2.0637 3.765 6.9956 7.1218 8.368 9.27117 9.9557
Girder Gbottom Mpa 7.7455 7.5958 7.4803 8.0913 9.6332 9.3292 7.093 5.81399 4.9203
8.1) Rare Combination LC-SR8.1 : At day 36500 + temperature stresses
Total Stresses (A+B)
Gtop Mpa 1.0967 1.2 1.2718 3.0474 6.3529 6.4791 7.725 8.62843 9.313
Girder Gbottom Mpa 9.429 9.2793 9.1637 9.5004 10.765 10.461 8.226 6.94628 6.0526
8.2) Rare Combination LC-SR8.2 : At day 36500 - temperature stresses
Total Stresses (A+B)
Gtop Mpa 2.2787 2.382 2.4538 4.2218 7.5196 7.6458 8.892 9.79514 10.48
Girder Gbottom Mpa 5.8382 5.6885 5.573 6.3677 8.0949 7.7909 5.555 4.27572 3.3821
8.3) Rare Combination LC-SR8.3 : At day 36500 + temperature stresses
Total Stresses (A+B)
Gtop Mpa 0.5688 0.6571 0.7146 2.4093 5.6336 5.7284 6.783 7.59209 8.2198
Girder Gbottom Mpa 10.551 10.427 10.336 10.763 12.224 11.995 10.22 9.17087 8.4147
8.4) Rare Combination LC-SR8.4 : At day 36500 - temperature stresses
Total Stresses (A+B)
Gtop Mpa 2.5388 2.6271 2.6846 4.3666 7.5781 7.6729 8.727 9.5366 10.164
Girder Gbottom Mpa 4.5667 4.4426 4.3515 5.5416 7.7726 7.5444 5.772 4.71994 3.9637

FREQUENT LOAD COMBINATIONS :


1) Frequent Combination LC-SF1 : At day 92 Structure open to LL
Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.7533 0.5473 0.3666 -0.53 -0.482 -0.7734 -4.349 -6.25093 -6.5622
Girder Gbottom Mpa 9.5277 9.7449 9.9351 14.245 21.051 21.362 25.26 27.4856 27.983

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.788 5.95593 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.8538 -4.808 -5.98034 -6.3712

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.491 4.45644 4.7698
Girder Gbottom Mpa 0.0017 -0.098 -0.164 -0.88 -1.851 -1.9424 -3.505 -4.4747 -4.7893

EPC Contractor-M/s Krishna Constructions 115


Design ch-109+720
Design of PSC Girder

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0115 0.0211 0.1118 0.2074 0.2199 0.376 0.46944 0.4999
Deck Dbottom Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.283 0.35378 0.3767
Gtop Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.283 0.35378 0.3767
Girder Gbottom Mpa 0 -0.016 -0.029 -0.175 -0.378 -0.4007 -0.685 -0.8554 -0.9108
F) Stresses due to Live load (Without SV) Load factor = 0.75
Dtop Mpa 0 0.0564 0.1105 0.6175 1.1577 1.2825 2.046 2.41974 2.646
Deck Dbottom Mpa 0 0.0448 0.0878 0.479 0.8725 0.9665 1.542 1.82356 1.9941
Gtop Mpa 0 0.0448 0.0878 0.479 0.8725 0.9665 1.542 1.82356 1.9941
Girder Gbottom Mpa 0 -0.077 -0.15 -0.969 -2.11 -2.3369 -3.728 -4.40917 -4.8215
F.1) Stresses due to Live load (With SV) Load factor = 0.75
Dtop Mpa 0 0.0367 0.0747 0.4269 0.8079 0.8619 1.524 1.98937 2.0575
Deck Dbottom Mpa 0 0.0291 0.0593 0.3312 0.6089 0.6495 1.149 1.49923 1.5505
Gtop Mpa 0 0.0291 0.0593 0.3312 0.6089 0.6495 1.149 1.49923 1.5505
Girder Gbottom Mpa 0 -0.05 -0.102 -0.67 -1.472 -1.5705 -2.777 -3.62497 -3.749

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.173 -0.173 -0.173 -0.154 -0.116 -0.1158 -0.116 -0.11579 -0.1158
Deck Dbottom Mpa -0.213 -0.213 -0.213 -0.195 -0.158 -0.1585 -0.158 -0.15849 -0.1585
Gtop Mpa 0.2681 0.2681 0.2681 0.2857 0.3223 0.3223 0.322 0.32233 0.3223
Girder Gbottom Mpa -0.144 -0.144 -0.144 -0.141 -0.124 -0.1242 -0.124 -0.12416 -0.1242
G) Stresses due to wind Load factor = 0.5
Dtop Mpa 0 0.0056 0.0104 0.055 0.1021 0.1083 0.185 0.23111 0.2461
Deck Dbottom Mpa 0 0.0045 0.0083 0.0427 0.0769 0.0816 0.139 0.17417 0.1855
Gtop Mpa 0 0.0045 0.0083 0.0427 0.0769 0.0816 0.139 0.17417 0.1855
Girder Gbottom Mpa 0 -0.008 -0.014 -0.086 -0.186 -0.1973 -0.337 -0.42112 -0.4484
Total Stresses (A+B +C+D+E+F+G) (Without SV Loading)
Dtop Mpa -0.173 -0.105 -0.042 0.575 1.2493 1.3866 2.306 2.7734 3.0301
Deck Dbottom Mpa -0.213 -0.159 -0.108 0.3706 0.8703 0.9737 1.667 2.01885 2.2123
Gtop Mpa 1.0103 1.0776 1.1163 2.4903 5.3993 5.4578 6.078 6.66112 7.2459
Girder Gbottom Mpa 9.3954 9.294 9.2236 10.753 13.891 13.705 12.41 11.6418 10.966
Total Stresses (A+B +C+D+E+F+G) (With SV Loading)
Dtop Mpa -0.173 -0.125 -0.077 0.3844 0.8995 0.966 1.784 2.34303 2.4415
Deck Dbottom Mpa -0.213 -0.174 -0.137 0.2228 0.6067 0.6568 1.273 1.69452 1.7688
Gtop Mpa 1.0103 1.0619 1.0878 2.3425 5.1357 5.1408 5.685 6.33679 6.8024
Girder Gbottom Mpa 9.3954 9.3209 9.2723 11.052 14.528 14.471 13.36 12.426 12.038
Total Stresses (A+B +C+D+E+F+G) wind downward
Dtop Mpa -0.173 -0.1 -0.031 0.63 1.3514 1.4949 2.491 3.00451 3.2762
Deck Dbottom Mpa -0.213 -0.154 -0.1 0.4133 0.9472 1.0553 1.806 2.19302 2.3978
Gtop Mpa 1.0103 1.0821 1.1245 2.533 5.4762 5.5394 6.218 6.83529 7.4314
Girder Gbottom Mpa 9.3954 9.2863 9.2095 10.667 13.705 13.507 12.08 11.2207 10.517
Total Stresses (A+B +C+D+E+F+G) wind upward
Dtop Mpa -0.173 -0.111 -0.052 0.52 1.1472 1.2783 2.121 2.54229 2.784
Deck Dbottom Mpa -0.213 -0.163 -0.116 0.3279 0.7933 0.8921 1.527 1.84468 2.0268
Gtop Mpa 1.0103 1.0731 1.108 2.4477 5.3223 5.3762 5.939 6.48695 7.0604
Girder Gbottom Mpa 9.3954 9.3017 9.2377 10.839 14.077 13.902 12.75 12.0629 11.414

EPC Contractor-M/s Krishna Constructions 116


Design ch-109+720
Design of PSC Girder

Max Compressive stress = 14.528 Mpa < 24 Mpa OK


Max Tensile Stress = 1.0103 Mpa >= -3.516 Mpa OK
Max Compressive stress (wind downward) = 13.705 Mpa < 24 Mpa OK
Max Tensile Stress (wind downward) = 1.0103 Mpa >= -3.516 Mpa OK
Max Compressive stress (wind upward) = 14.077 Mpa < 24 Mpa OK
Max Tensile Stress (wind upward) = 1.0103 Mpa >= -3.516 Mpa OK

1.1) Frequent Combination LC-SF1.1 : At day 92 Structure open to LL + temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.7533 0.5473 0.3666 -0.53 -0.482 -0.7734 -4.349 -6.25093 -6.5622
Girder Gbottom Mpa 9.5277 9.7449 9.9351 14.245 21.051 21.362 25.26 27.4856 27.983

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.788 5.95593 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.8538 -4.808 -5.98034 -6.3712

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.491 4.45644 4.7698
Girder Gbottom Mpa 0.0017 -0.098 -0.164 -0.88 -1.851 -1.9424 -3.505 -4.4747 -4.7893

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0115 0.0211 0.1118 0.2074 0.2199 0.376 0.46944 0.4999
Deck Dbottom Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.283 0.35378 0.3767
Gtop Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.283 0.35378 0.3767
Girder Gbottom Mpa 0 -0.016 -0.029 -0.175 -0.378 -0.4007 -0.685 -0.8554 -0.9108
F) Stresses due to Live load (Without SV) Load factor = 0.75
Dtop Mpa 0 0.0564 0.1105 0.6175 1.1577 1.2825 2.046 2.41974 2.646
Deck Dbottom Mpa 0 0.0448 0.0878 0.479 0.8725 0.9665 1.542 1.82356 1.9941
Gtop Mpa 0 0.0448 0.0878 0.479 0.8725 0.9665 1.542 1.82356 1.9941
Girder Gbottom Mpa 0 -0.077 -0.15 -0.969 -2.11 -2.3369 -3.728 -4.40917 -4.8215
F.1) Stresses due to Live load (With SV) Load factor = 0.75
Dtop Mpa 0 0.0367 0.0747 0.4269 0.8079 0.8619 1.524 1.98937 2.0575
Deck Dbottom Mpa 0 0.0291 0.0593 0.3312 0.6089 0.6495 1.149 1.49923 1.5505
Gtop Mpa 0 0.0291 0.0593 0.3312 0.6089 0.6495 1.149 1.49923 1.5505
Girder Gbottom Mpa 0 -0.05 -0.102 -0.67 -1.472 -1.5705 -2.777 -3.62497 -3.749

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.173 -0.173 -0.173 -0.154 -0.116 -0.1158 -0.116 -0.11579 -0.1158
Deck Dbottom Mpa -0.213 -0.213 -0.213 -0.195 -0.158 -0.1585 -0.158 -0.15849 -0.1585
Gtop Mpa 0.2681 0.2681 0.2681 0.2857 0.3223 0.3223 0.322 0.32233 0.3223
Girder Gbottom Mpa -0.144 -0.144 -0.144 -0.141 -0.124 -0.1242 -0.124 -0.12416 -0.1242

EPC Contractor-M/s Krishna Constructions 117


Design ch-109+720
Design of PSC Girder

H) +ve temperature stresses Load factor = 0.5


Dtop Mpa 2.26 2.26 2.26 2.3498 2.4404 2.4404 2.44 2.4404 2.4404
Deck Dbottom Mpa -0.66 -0.66 -0.66 -0.598 -0.536 -0.5356 -0.536 -0.53561 -0.5356
Gtop Mpa -0.66 -0.66 -0.66 -0.598 -0.536 -0.5356 -0.536 -0.53561 -0.5356
Girder Gbottom Mpa 1.4029 1.4029 1.4029 1.1743 0.9436 0.9436 0.944 0.94358 0.9436
Total Stresses (A+B +C+D+E+F+G) (Without SV Loading)
Dtop Mpa 2.0867 2.1546 2.2183 2.9248 3.6897 3.827 4.746 5.2138 5.4705
Deck Dbottom Mpa -0.873 -0.819 -0.768 -0.227 0.3347 0.4381 1.131 1.48324 1.6767
Gtop Mpa 0.3504 0.4177 0.4564 1.8923 4.8636 4.9222 5.543 6.12551 6.7103
Girder Gbottom Mpa 10.798 10.697 10.626 11.927 14.835 14.648 13.36 12.5854 11.909
Total Stresses (A+B +C+D+E+F+G) (With SV Loading)
Dtop Mpa -0.173 -0.125 -0.077 0.3844 0.8995 0.966 1.784 2.34303 2.4415
Deck Dbottom Mpa -0.213 -0.174 -0.137 0.2228 0.6067 0.6568 1.273 1.69452 1.7688
Gtop Mpa 1.0103 1.0619 1.0878 2.3425 5.1357 5.1408 5.685 6.33679 6.8024
Girder Gbottom Mpa 9.3954 9.3209 9.2723 11.052 14.528 14.471 13.36 12.426 12.038

Max Compressive stress = 14.835 Mpa < 24 Mpa OK


Max Tensile Stress = 0.3504 Mpa >= -3.516 Mpa OK

1.2) Frequent Combination LC-SF1.2 : At day 92 Structure open to LL - temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.7533 0.5473 0.3666 -0.53 -0.482 -0.7734 -4.349 -6.25093 -6.5622
Girder Gbottom Mpa 9.5277 9.7449 9.9351 14.245 21.051 21.362 25.26 27.4856 27.983

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.788 5.95593 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.8538 -4.808 -5.98034 -6.3712

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.491 4.45644 4.7698
Girder Gbottom Mpa 0.0017 -0.098 -0.164 -0.88 -1.851 -1.9424 -3.505 -4.4747 -4.7893

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0115 0.0211 0.1118 0.2074 0.2199 0.376 0.46944 0.4999
Deck Dbottom Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.283 0.35378 0.3767
Gtop Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.283 0.35378 0.3767
Girder Gbottom Mpa 0 -0.016 -0.029 -0.175 -0.378 -0.4007 -0.685 -0.8554 -0.9108
F) Stresses due to Live load (Without SV) Load factor = 0.75
Dtop Mpa 0 0.0564 0.1105 0.6175 1.1577 1.2825 2.046 2.41974 2.646
Deck Dbottom Mpa 0 0.0448 0.0878 0.479 0.8725 0.9665 1.542 1.82356 1.9941
Gtop Mpa 0 0.0448 0.0878 0.479 0.8725 0.9665 1.542 1.82356 1.9941
Girder Gbottom Mpa 0 -0.077 -0.15 -0.969 -2.11 -2.3369 -3.728 -4.40917 -4.8215

EPC Contractor-M/s Krishna Constructions 118


Design ch-109+720
Design of PSC Girder

F.1) Stresses due to Live load (With SV) Load factor = 0.75
Dtop Mpa 0 0.0367 0.0747 0.4269 0.8079 0.8619 1.524 1.98937 2.0575
Deck Dbottom Mpa 0 0.0291 0.0593 0.3312 0.6089 0.6495 1.149 1.49923 1.5505
Gtop Mpa 0 0.0291 0.0593 0.3312 0.6089 0.6495 1.149 1.49923 1.5505
Girder Gbottom Mpa 0 -0.05 -0.102 -0.67 -1.472 -1.5705 -2.777 -3.62497 -3.749

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.173 -0.173 -0.173 -0.154 -0.116 -0.1158 -0.116 -0.11579 -0.1158
Deck Dbottom Mpa -0.213 -0.213 -0.213 -0.195 -0.158 -0.1585 -0.158 -0.15849 -0.1585
Gtop Mpa 0.2681 0.2681 0.2681 0.2857 0.3223 0.3223 0.322 0.32233 0.3223
Girder Gbottom Mpa -0.144 -0.144 -0.144 -0.141 -0.124 -0.1242 -0.124 -0.12416 -0.1242
H) -ve temperature stresses Load factor = 0.5
Dtop Mpa -1.416 -1.416 -1.416 -1.37 -1.323 -1.3231 -1.323 -1.3231 -1.3231
Deck Dbottom Mpa 0.3251 0.3251 0.3251 0.3806 0.4366 0.4366 0.437 0.43664 0.4366
Gtop Mpa 0.3251 0.3251 0.3251 0.3806 0.4366 0.4366 0.437 0.43664 0.4366
Girder Gbottom Mpa -1.589 -1.589 -1.589 -1.436 -1.282 -1.2819 -1.282 -1.28189 -1.2819
Total Stresses (A+B +C+D+E+F+G) (Without SV Loading)
Dtop Mpa -1.589 -1.521 -1.457 -0.795 -0.074 0.0635 0.983 1.4503 1.707
Deck Dbottom Mpa 0.1124 0.1663 0.2169 0.7512 1.3069 1.4104 2.103 2.45549 2.6489
Gtop Mpa 1.3354 1.4027 1.4413 2.871 5.8359 5.8944 6.515 7.09776 7.6825
Girder Gbottom Mpa 7.806 7.7046 7.6342 9.3165 12.609 12.423 11.13 10.3599 9.6838
Total Stresses (A+B +C+D+E+F+G) (With SV Loading)
Dtop Mpa -0.173 -0.125 -0.077 0.3844 0.8995 0.966 1.784 2.34303 2.4415
Deck Dbottom Mpa -0.213 -0.174 -0.137 0.2228 0.6067 0.6568 1.273 1.69452 1.7688
Gtop Mpa 1.0103 1.0619 1.0878 2.3425 5.1357 5.1408 5.685 6.33679 6.8024
Girder Gbottom Mpa 9.3954 9.3209 9.2723 11.052 14.528 14.471 13.36 12.426 12.038

Max Compressive stress = 14.528 Mpa < 24 Mpa OK


Max Tensile Stress = 1.0103 Mpa >= -3.516 Mpa OK

1.3) Frequent Combination LC-SF1.3 : At day 92 Structure open to LL + temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.7533 0.5473 0.3666 -0.53 -0.482 -0.7734 -4.349 -6.25093 -6.5622
Girder Gbottom Mpa 9.5277 9.7449 9.9351 14.245 21.051 21.362 25.26 27.4856 27.983

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.788 5.95593 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.8538 -4.808 -5.98034 -6.3712

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.491 4.45644 4.7698
Girder Gbottom Mpa 0.0017 -0.098 -0.164 -0.88 -1.851 -1.9424 -3.505 -4.4747 -4.7893

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0115 0.0211 0.1118 0.2074 0.2199 0.376 0.46944 0.4999
Deck Dbottom Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.283 0.35378 0.3767
Gtop Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.283 0.35378 0.3767
Girder Gbottom Mpa 0 -0.016 -0.029 -0.175 -0.378 -0.4007 -0.685 -0.8554 -0.9108
F) Stresses due to Live load (Without SV) Load factor = 0.2
Dtop Mpa 0 0.0151 0.0295 0.1647 0.3087 0.342 0.546 0.64526 0.7056
Deck Dbottom Mpa 0 0.012 0.0234 0.1277 0.2327 0.2577 0.411 0.48628 0.5318

EPC Contractor-M/s Krishna Constructions 119


Design ch-109+720
Design of PSC Girder

Gtop Mpa 0 0.012 0.0234 0.1277 0.2327 0.2577 0.411 0.48628 0.5318
Girder Gbottom Mpa 0 -0.02 -0.04 -0.258 -0.563 -0.6232 -0.994 -1.17578 -1.2857
F.1) Stresses due to Live load (With SV) Load factor = 0.2
Dtop Mpa 0 0.0098 0.0199 0.1138 0.2155 0.2298 0.406 0.5305 0.5487
Deck Dbottom Mpa 0 0.0078 0.0158 0.0883 0.1624 0.1732 0.306 0.39979 0.4135
Gtop Mpa 0 0.0078 0.0158 0.0883 0.1624 0.1732 0.306 0.39979 0.4135
Girder Gbottom Mpa 0 -0.013 -0.027 -0.179 -0.393 -0.4188 -0.741 -0.96666 -0.9997

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.173 -0.173 -0.173 -0.154 -0.116 -0.1158 -0.116 -0.11579 -0.1158
Deck Dbottom Mpa -0.213 -0.213 -0.213 -0.195 -0.158 -0.1585 -0.158 -0.15849 -0.1585
Gtop Mpa 0.2681 0.2681 0.2681 0.2857 0.3223 0.3223 0.322 0.32233 0.3223
Girder Gbottom Mpa -0.144 -0.144 -0.144 -0.141 -0.124 -0.1242 -0.124 -0.12416 -0.1242
H) +ve temperature stresses Load factor = 0.6
Dtop Mpa 2.712 2.712 2.712 2.8197 2.9285 2.9285 2.928 2.92848 2.9285
Deck Dbottom Mpa -0.792 -0.792 -0.792 -0.718 -0.643 -0.6427 -0.643 -0.64273 -0.6427
Gtop Mpa -0.792 -0.792 -0.792 -0.718 -0.643 -0.6427 -0.643 -0.64273 -0.6427
Girder Gbottom Mpa 1.6835 1.6835 1.6835 1.4091 1.1323 1.1323 1.132 1.1323 1.1323
Total Stresses (A+B +C+D+E+F+G) (Without SV Loading)
Dtop Mpa 2.5387 2.5652 2.5893 2.9419 3.3288 3.3746 3.734 3.9274 4.0182
Deck Dbottom Mpa -1.005 -0.984 -0.964 -0.698 -0.412 -0.3778 -0.107 0.03884 0.1072
Gtop Mpa 0.2184 0.2529 0.26 1.4214 4.1167 4.1063 4.305 4.68111 5.1408
Girder Gbottom Mpa 11.079 11.034 11.017 12.873 16.57 16.551 16.28 16.0075 15.634
Total Stresses (A+B +C+D+E+F+G) (With SV Loading)
Dtop Mpa -0.173 -0.152 -0.132 0.0713 0.307 0.3339 0.667 0.88416 0.9327
Deck Dbottom Mpa -0.213 -0.196 -0.18 -0.02 0.1602 0.1804 0.431 0.59508 0.6317
Gtop Mpa 1.0103 1.0406 1.0443 2.0997 4.6892 4.6645 4.843 5.23735 5.6653
Girder Gbottom Mpa 9.3954 9.3575 9.3468 11.543 15.608 15.623 15.4 15.0843 14.787

Max Compressive stress = 16.57 Mpa < 24 Mpa OK


Max Tensile Stress = 0.2184 Mpa >= -3.516 Mpa OK

1.4) Frequent Combination LC-SF1.4 : At day 92 Structure open to LL - temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.7533 0.5473 0.3666 -0.53 -0.482 -0.7734 -4.349 -6.25093 -6.5622
Girder Gbottom Mpa 9.5277 9.7449 9.9351 14.245 21.051 21.362 25.26 27.4856 27.983

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.788 5.95593 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.8538 -4.808 -5.98034 -6.3712

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.491 4.45644 4.7698
Girder Gbottom Mpa 0.0017 -0.098 -0.164 -0.88 -1.851 -1.9424 -3.505 -4.4747 -4.7893

D) Stresses due to transfer over permanent


Load
bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0

EPC Contractor-M/s Krishna Constructions 120


Design ch-109+720
Design of PSC Girder

E) Stresses due to placement of SIDL Load factor = 1


Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0115 0.0211 0.1118 0.2074 0.2199 0.376 0.46944 0.4999
Deck Dbottom Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.283 0.35378 0.3767
Gtop Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.283 0.35378 0.3767
Girder Gbottom Mpa 0 -0.016 -0.029 -0.175 -0.378 -0.4007 -0.685 -0.8554 -0.9108
F) Stresses due to Live load (Without SV) Load factor = 0.2
Dtop Mpa 0 0.0151 0.0295 0.1647 0.3087 0.342 0.546 0.64526 0.7056
Deck Dbottom Mpa 0 0.012 0.0234 0.1277 0.2327 0.2577 0.411 0.48628 0.5318
Gtop Mpa 0 0.012 0.0234 0.1277 0.2327 0.2577 0.411 0.48628 0.5318
Girder Gbottom Mpa 0 -0.02 -0.04 -0.258 -0.563 -0.6232 -0.994 -1.17578 -1.2857
F.1) Stresses due to Live load (With SV) Load factor = 0.2
Dtop Mpa 0 0.0098 0.0199 0.1138 0.2155 0.2298 0.406 0.5305 0.5487
Deck Dbottom Mpa 0 0.0078 0.0158 0.0883 0.1624 0.1732 0.306 0.39979 0.4135
Gtop Mpa 0 0.0078 0.0158 0.0883 0.1624 0.1732 0.306 0.39979 0.4135
Girder Gbottom Mpa 0 -0.013 -0.027 -0.179 -0.393 -0.4188 -0.741 -0.96666 -0.9997

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.173 -0.173 -0.173 -0.154 -0.116 -0.1158 -0.116 -0.11579 -0.1158
Deck Dbottom Mpa -0.213 -0.213 -0.213 -0.195 -0.158 -0.1585 -0.158 -0.15849 -0.1585
Gtop Mpa 0.2681 0.2681 0.2681 0.2857 0.3223 0.3223 0.322 0.32233 0.3223
Girder Gbottom Mpa -0.144 -0.144 -0.144 -0.141 -0.124 -0.1242 -0.124 -0.12416 -0.1242
H) -ve temperature stresses Load factor = 0.6
Dtop Mpa -1.699 -1.699 -1.699 -1.643 -1.588 -1.5877 -1.588 -1.58772 -1.5877
Deck Dbottom Mpa 0.3901 0.3901 0.3901 0.4567 0.524 0.524 0.524 0.52397 0.524
Gtop Mpa 0.3901 0.3901 0.3901 0.4567 0.524 0.524 0.524 0.52397 0.524
Girder Gbottom Mpa -1.907 -1.907 -1.907 -1.724 -1.538 -1.5383 -1.538 -1.53827 -1.5383
Total Stresses (A+B +C+D+E+F+G) (Without SV Loading)
Dtop Mpa -1.872 -1.845 -1.821 -1.521 -1.187 -1.1416 -0.782 -0.5888 -0.498
Deck Dbottom Mpa 0.1774 0.1985 0.2176 0.4761 0.7544 0.7889 1.06 1.20554 1.2739
Gtop Mpa 1.4004 1.4349 1.442 2.5958 5.2834 5.273 5.472 5.84781 6.3075
Girder Gbottom Mpa 7.4881 7.443 7.4265 9.7398 13.9 13.88 13.61 13.3369 12.963
Total Stresses (A+B +C+D+E+F+G) (With SV Loading)
Dtop Mpa -0.173 -0.152 -0.132 0.0713 0.307 0.3339 0.667 0.88416 0.9327
Deck Dbottom Mpa -0.213 -0.196 -0.18 -0.02 0.1602 0.1804 0.431 0.59508 0.6317
Gtop Mpa 1.0103 1.0406 1.0443 2.0997 4.6892 4.6645 4.843 5.23735 5.6653
Girder Gbottom Mpa 9.3954 9.3575 9.3468 11.543 15.608 15.623 15.4 15.0843 14.787

Max Compressive stress = 15.623 Mpa < 24 Mpa OK


Max Tensile Stress = 1.0103 Mpa >= -3.516 Mpa OK

2) Frequent Combination LC-SF2 : At day 36500


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.7963 0.6113 0.4494 -0.305 -0.181 -0.4358 -3.577 -5.25302 -5.5213
Girder Gbottom Mpa 8.3259 8.5203 8.6899 12.346 17.884 18.153 21.57 23.5143 23.931

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.788 5.95593 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.8538 -4.808 -5.98034 -6.3712

EPC Contractor-M/s Krishna Constructions 121


Design ch-109+720
Design of PSC Girder

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.491 4.45644 4.7698
Girder Gbottom Mpa 0.0017 -0.098 -0.164 -0.88 -1.851 -1.9424 -3.505 -4.4747 -4.7893

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.1) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.2) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0115 0.0211 0.1118 0.2074 0.2199 0.376 0.46944 0.4999
Deck Dbottom Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.283 0.35378 0.3767
Gtop Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.283 0.35378 0.3767
Girder Gbottom Mpa 0 -0.016 -0.029 -0.175 -0.378 -0.4007 -0.685 -0.8554 -0.9108
F) Stresses due to Live load (Without SV) Load factor = 0.75
Dtop Mpa 0 0.0564 0.1105 0.6175 1.1577 1.2825 2.046 2.41974 2.646
Deck Dbottom Mpa 0 0.0448 0.0878 0.479 0.8725 0.9665 1.542 1.82356 1.9941
Gtop Mpa 0 0.0448 0.0878 0.479 0.8725 0.9665 1.542 1.82356 1.9941
Girder Gbottom Mpa 0 -0.077 -0.15 -0.969 -2.11 -2.3369 -3.728 -4.40917 -4.8215
F.1) Stresses due to Live load (With SV) Load factor = 0.75
Dtop Mpa 0 0.0367 0.0747 0.4269 0.8079 0.8619 1.524 1.98937 2.0575
Deck Dbottom Mpa 0 0.0291 0.0593 0.3312 0.6089 0.6495 1.149 1.49923 1.5505
Gtop Mpa 0 0.0291 0.0593 0.3312 0.6089 0.6495 1.149 1.49923 1.5505
Girder Gbottom Mpa 0 -0.05 -0.102 -0.67 -1.472 -1.5705 -2.777 -3.62497 -3.749

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.713 -0.713 -0.713 -0.635 -0.477 -0.4765 -0.477 -0.47654 -0.4765
Deck Dbottom Mpa -0.875 -0.875 -0.875 -0.803 -0.652 -0.6523 -0.652 -0.65231 -0.6523
Gtop Mpa 1.1035 1.1035 1.1035 1.1759 1.3266 1.3266 1.327 1.32662 1.3266
Girder Gbottom Mpa -0.592 -0.592 -0.592 -0.58 -0.511 -0.511 -0.511 -0.511 -0.511
Total Stresses (A+B +C+D+E+F+G) (Without SV Loading)
Dtop Mpa -0.713 -0.645 -0.582 0.0943 0.8886 1.0258 1.945 2.41265 2.6693
Deck Dbottom Mpa -0.875 -0.822 -0.771 -0.237 0.3765 0.4799 1.173 1.52504 1.7185
Gtop Mpa 1.8886 1.9769 2.0344 3.6054 6.7048 6.7997 7.854 8.66331 9.291
Girder Gbottom Mpa 7.7455 7.6214 7.5304 8.4143 10.336 10.108 8.336 7.28371 6.5275
Total Stresses (A+B +C+D+E+F+G) (With SV Loading)
Dtop Mpa -0.713 -0.665 -0.617 -0.096 0.5388 0.6052 1.423 1.98228 2.0808
Deck Dbottom Mpa -0.875 -0.837 -0.799 -0.385 0.1129 0.1629 0.78 1.2007 1.275
Gtop Mpa 1.8886 1.9613 2.006 3.4575 6.4412 6.4827 7.461 8.33898 8.8475
Girder Gbottom Mpa 7.7455 7.6483 7.5791 8.7133 10.974 10.875 9.287 8.06792 7.5999

Max Compressive stress = 10.974 Mpa < 24 Mpa OK


Max Tensile Stress = 1.8886 Mpa >= -3.516 Mpa OK

2.1) Frequent Combination LC-SF2.1 : At day 36500 + temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.7963 0.6113 0.4494 -0.305 -0.181 -0.4358 -3.577 -5.25302 -5.5213
Girder Gbottom Mpa 8.3259 8.5203 8.6899 12.346 17.884 18.153 21.57 23.5143 23.931

EPC Contractor-M/s Krishna Constructions 122


Design ch-109+720
Design of PSC Girder

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.788 5.95593 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.8538 -4.808 -5.98034 -6.3712

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.491 4.45644 4.7698
Girder Gbottom Mpa 0.0017 -0.098 -0.164 -0.88 -1.851 -1.9424 -3.505 -4.4747 -4.7893

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.1) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.2) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0115 0.0211 0.1118 0.2074 0.2199 0.376 0.46944 0.4999
Deck Dbottom Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.283 0.35378 0.3767
Gtop Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.283 0.35378 0.3767
Girder Gbottom Mpa 0 -0.016 -0.029 -0.175 -0.378 -0.4007 -0.685 -0.8554 -0.9108
F) Stresses due to Live load (Without SV) Load factor = 0.75
Dtop Mpa 0 0.0564 0.1105 0.6175 1.1577 1.2825 2.046 2.41974 2.646
Deck Dbottom Mpa 0 0.0448 0.0878 0.479 0.8725 0.9665 1.542 1.82356 1.9941
Gtop Mpa 0 0.0448 0.0878 0.479 0.8725 0.9665 1.542 1.82356 1.9941
Girder Gbottom Mpa 0 -0.077 -0.15 -0.969 -2.11 -2.3369 -3.728 -4.40917 -4.8215
F.1) Stresses due to Live load (With SV) Load factor = 0.75
Dtop Mpa 0 0.0367 0.0747 0.4269 0.8079 0.8619 1.524 1.98937 2.0575
Deck Dbottom Mpa 0 0.0291 0.0593 0.3312 0.6089 0.6495 1.149 1.49923 1.5505
Gtop Mpa 0 0.0291 0.0593 0.3312 0.6089 0.6495 1.149 1.49923 1.5505
Girder Gbottom Mpa 0 -0.05 -0.102 -0.67 -1.472 -1.5705 -2.777 -3.62497 -3.749
G) Stresses due to differential shrinkage Load factor = 1
Dtop Mpa -0.713 -0.713 -0.713 -0.635 -0.477 -0.4765 -0.477 -0.47654 -0.4765
Deck Dbottom Mpa -0.875 -0.875 -0.875 -0.803 -0.652 -0.6523 -0.652 -0.65231 -0.6523
Gtop Mpa 1.1035 1.1035 1.1035 1.1759 1.3266 1.3266 1.327 1.32662 1.3266
Girder Gbottom Mpa -0.592 -0.592 -0.592 -0.58 -0.511 -0.511 -0.511 -0.511 -0.511
H) +ve temperature stresses Load factor = 0.5
Dtop Mpa 2.26 2.26 2.26 2.3498 2.4404 2.4404 2.44 2.4404 2.4404
Deck Dbottom Mpa -0.66 -0.66 -0.66 -0.598 -0.536 -0.5356 -0.536 -0.53561 -0.5356
Gtop Mpa -0.66 -0.66 -0.66 -0.598 -0.536 -0.5356 -0.536 -0.53561 -0.5356
Girder Gbottom Mpa 1.4029 1.4029 1.4029 1.1743 0.9436 0.9436 0.944 0.94358 0.9436
Total Stresses (A+B +C+D+E+F+G) (Without SV Loading)
Dtop Mpa 1.5467 1.6146 1.6783 2.444 3.329 3.4662 4.386 4.85305 5.1097
Deck Dbottom Mpa -1.535 -1.481 -1.431 -0.835 -0.159 -0.0557 0.637 0.98943 1.1829
Gtop Mpa 1.2287 1.317 1.3745 3.0073 6.1692 6.264 7.318 8.1277 8.7554
Girder Gbottom Mpa 9.1484 9.0243 8.9332 9.5886 11.28 11.052 9.279 8.22729 7.4711
Total Stresses (A+B +C+D+E+F+G) (With SV Loading)
Dtop Mpa -0.713 -0.665 -0.617 -0.096 0.5388 0.6052 1.423 1.98228 2.0808
Deck Dbottom Mpa -0.875 -0.837 -0.799 -0.385 0.1129 0.1629 0.78 1.2007 1.275
Gtop Mpa 1.8886 1.9613 2.006 3.4575 6.4412 6.4827 7.461 8.33898 8.8475
Girder Gbottom Mpa 7.7455 7.6483 7.5791 8.7133 10.974 10.875 9.287 8.06792 7.5999

Max Compressive stress = 11.28 Mpa < 24 Mpa OK


Max Tensile Stress = 1.2287 Mpa >= -3.516 Mpa OK

2.2) Frequent Combination LC-S2.2 : At day 36500 - temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.7963 0.6113 0.4494 -0.305 -0.181 -0.4358 -3.577 -5.25302 -5.5213
Girder

EPC Contractor-M/s Krishna Constructions 123


Design ch-109+720
Design of PSC Girder

Girder Gbottom Mpa 8.3259 8.5203 8.6899 12.346 17.884 18.153 21.57 23.5143 23.931

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.788 5.95593 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.8538 -4.808 -5.98034 -6.3712

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.491 4.45644 4.7698
Girder Gbottom Mpa 0.0017 -0.098 -0.164 -0.88 -1.851 -1.9424 -3.505 -4.4747 -4.7893

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.1) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.2) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0115 0.0211 0.1118 0.2074 0.2199 0.376 0.46944 0.4999
Deck Dbottom Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.283 0.35378 0.3767
Gtop Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.283 0.35378 0.3767
Girder Gbottom Mpa 0 -0.016 -0.029 -0.175 -0.378 -0.4007 -0.685 -0.8554 -0.9108
F) Stresses due to Live load (Without SV) Load factor = 0.75
Dtop Mpa 0 0.0564 0.1105 0.6175 1.1577 1.2825 2.046 2.41974 2.646
Deck Dbottom Mpa 0 0.0448 0.0878 0.479 0.8725 0.9665 1.542 1.82356 1.9941
Gtop Mpa 0 0.0448 0.0878 0.479 0.8725 0.9665 1.542 1.82356 1.9941
Girder Gbottom Mpa 0 -0.077 -0.15 -0.969 -2.11 -2.3369 -3.728 -4.40917 -4.8215
F.1) Stresses due to Live load (With SV) Load factor = 0.75
Dtop Mpa 0 0.0367 0.0747 0.4269 0.8079 0.8619 1.524 1.98937 2.0575
Deck Dbottom Mpa 0 0.0291 0.0593 0.3312 0.6089 0.6495 1.149 1.49923 1.5505
Gtop Mpa 0 0.0291 0.0593 0.3312 0.6089 0.6495 1.149 1.49923 1.5505
Girder Gbottom Mpa 0 -0.05 -0.102 -0.67 -1.472 -1.5705 -2.777 -3.62497 -3.749
G) Stresses due to differential shrinkage Load factor = 1
Dtop Mpa -0.713 -0.713 -0.713 -0.635 -0.477 -0.4765 -0.477 -0.47654 -0.4765
Deck Dbottom Mpa -0.875 -0.875 -0.875 -0.803 -0.652 -0.6523 -0.652 -0.65231 -0.6523
Gtop Mpa 1.1035 1.1035 1.1035 1.1759 1.3266 1.3266 1.327 1.32662 1.3266
Girder Gbottom Mpa -0.592 -0.592 -0.592 -0.58 -0.511 -0.511 -0.511 -0.511 -0.511
H) -ve temperature stresses Load factor = 0.5
Dtop Mpa -1.416 -1.416 -1.416 -1.37 -1.323 -1.3231 -1.323 -1.3231 -1.3231
Deck Dbottom Mpa 0.3251 0.3251 0.3251 0.3806 0.4366 0.4366 0.437 0.43664 0.4366
Gtop Mpa 0.3251 0.3251 0.3251 0.3806 0.4366 0.4366 0.437 0.43664 0.4366
Girder Gbottom Mpa -1.589 -1.589 -1.589 -1.436 -1.282 -1.2819 -1.282 -1.28189 -1.2819
Total Stresses (A+B +C+D+E+F+G) (Without SV Loading)
Dtop Mpa -2.129 -2.061 -1.997 -1.275 -0.435 -0.2973 0.622 1.08955 1.3462
Deck Dbottom Mpa -0.55 -0.496 -0.446 0.1433 0.8131 0.9166 1.609 1.96168 2.1551
Gtop Mpa 2.2137 2.302 2.3595 3.986 7.1414 7.2363 8.291 9.09995 9.7276
Girder Gbottom Mpa 6.1561 6.032 5.9409 6.9779 9.0545 8.8263 7.054 6.00182 5.2456

EPC Contractor-M/s Krishna Constructions 124


Design ch-109+720
Design of PSC Girder

Total Stresses (A+B +C+D+E+F+G) (With SV Loading)


Dtop Mpa -0.713 -0.665 -0.617 -0.096 0.5388 0.6052 1.423 1.98228 2.0808
Deck Dbottom Mpa -0.875 -0.837 -0.799 -0.385 0.1129 0.1629 0.78 1.2007 1.275
Gtop Mpa 1.8886 1.9613 2.006 3.4575 6.4412 6.4827 7.461 8.33898 8.8475
Girder Gbottom Mpa 7.7455 7.6483 7.5791 8.7133 10.974 10.875 9.287 8.06792 7.5999

Max Compressive stress = 10.974 Mpa < 24 Mpa OK


Max Tensile Stress = 1.8886 Mpa >= -3.516 Mpa OK

2.3) Frequent Combination LC-SF2.3 : At day 36500 + temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.7963 0.6113 0.4494 -0.305 -0.181 -0.4358 -3.577 -5.25302 -5.5213
Girder Gbottom Mpa 8.3259 8.5203 8.6899 12.346 17.884 18.153 21.57 23.5143 23.931

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.788 5.95593 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.8538 -4.808 -5.98034 -6.3712

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.491 4.45644 4.7698
Girder Gbottom Mpa 0.0017 -0.098 -0.164 -0.88 -1.851 -1.9424 -3.505 -4.4747 -4.7893

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.1) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.2) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0115 0.0211 0.1118 0.2074 0.2199 0.376 0.46944 0.4999
Deck Dbottom Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.283 0.35378 0.3767
Gtop Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.283 0.35378 0.3767
Girder Gbottom Mpa 0 -0.016 -0.029 -0.175 -0.378 -0.4007 -0.685 -0.8554 -0.9108
F) Stresses due to Live load (Without SV) Load factor = 0.2
Dtop Mpa 0 0.0151 0.0295 0.1647 0.3087 0.342 0.546 0.64526 0.7056
Deck Dbottom Mpa 0 0.012 0.0234 0.1277 0.2327 0.2577 0.411 0.48628 0.5318
Gtop Mpa 0 0.012 0.0234 0.1277 0.2327 0.2577 0.411 0.48628 0.5318
Girder Gbottom Mpa 0 -0.02 -0.04 -0.258 -0.563 -0.6232 -0.994 -1.17578 -1.2857
F.1) Stresses due to Live load (With SV) Load factor = 0.2
Dtop Mpa 0 0.0098 0.0199 0.1138 0.2155 0.2298 0.406 0.5305 0.5487
Deck Dbottom Mpa 0 0.0078 0.0158 0.0883 0.1624 0.1732 0.306 0.39979 0.4135
Gtop Mpa 0 0.0078 0.0158 0.0883 0.1624 0.1732 0.306 0.39979 0.4135
Girder Gbottom Mpa 0 -0.013 -0.027 -0.179 -0.393 -0.4188 -0.741 -0.96666 -0.9997

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.713 -0.713 -0.713 -0.635 -0.477 -0.4765 -0.477 -0.47654 -0.4765
Deck Dbottom Mpa -0.875 -0.875 -0.875 -0.803 -0.652 -0.6523 -0.652 -0.65231 -0.6523
Gtop Mpa 1.1035 1.1035 1.1035 1.1759 1.3266 1.3266 1.327 1.32662 1.3266
Girder Gbottom Mpa -0.592 -0.592 -0.592 -0.58 -0.511 -0.511 -0.511 -0.511 -0.511

EPC Contractor-M/s Krishna Constructions 125


Design ch-109+720
Design of PSC Girder

H) +ve temperature stresses Load factor = 0.6


Dtop Mpa 2.712 2.712 2.712 2.8197 2.9285 2.9285 2.928 2.92848 2.9285
Deck Dbottom Mpa -0.792 -0.792 -0.792 -0.718 -0.643 -0.6427 -0.643 -0.64273 -0.6427
Gtop Mpa -0.792 -0.792 -0.792 -0.718 -0.643 -0.6427 -0.643 -0.64273 -0.6427
Girder Gbottom Mpa 1.6835 1.6835 1.6835 1.4091 1.1323 1.1323 1.132 1.1323 1.1323
Total Stresses (A+B +C+D+E+F+G) (Without SV Loading)
Dtop Mpa 1.9987 2.0252 2.0493 2.4612 2.968 3.0138 3.373 3.56665 3.6574
Deck Dbottom Mpa -1.667 -1.646 -1.627 -1.306 -0.906 -0.8716 -0.601 -0.45497 -0.3866
Gtop Mpa 1.0967 1.1522 1.1782 2.5365 5.4222 5.4482 6.081 6.6833 7.1859
Girder Gbottom Mpa 9.429 9.3612 9.324 10.534 13.016 12.954 12.2 11.6494 11.196
Total Stresses (A+B +C+D+E+F+G) (With SV Loading)
Dtop Mpa -0.713 -0.692 -0.672 -0.409 -0.054 -0.0268 0.306 0.52341 0.572
Deck Dbottom Mpa -0.875 -0.859 -0.843 -0.628 -0.334 -0.3134 -0.063 0.10127 0.1379
Gtop Mpa 1.8886 1.9399 1.9625 3.2147 5.9947 6.0064 6.619 7.23954 7.7104
Girder Gbottom Mpa 7.7455 7.6849 7.6535 9.2046 12.053 12.026 11.32 10.7262 10.349

Max Compressive stress = 13.016 Mpa < 24 Mpa OK


Max Tensile Stress = 1.0967 Mpa >= -3.516 Mpa OK

2.4) Frequent Combination LC-SF2.4 : At day 36500 - temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.7963 0.6113 0.4494 -0.305 -0.181 -0.4358 -3.577 -5.25302 -5.5213
Girder Gbottom Mpa 8.3259 8.5203 8.6899 12.346 17.884 18.153 21.57 23.5143 23.931

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.788 5.95593 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.8538 -4.808 -5.98034 -6.3712

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.491 4.45644 4.7698
Girder Gbottom Mpa 0.0017 -0.098 -0.164 -0.88 -1.851 -1.9424 -3.505 -4.4747 -4.7893

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.1) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.2) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0115 0.0211 0.1118 0.2074 0.2199 0.376 0.46944 0.4999
Deck Dbottom Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.283 0.35378 0.3767
Gtop Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.283 0.35378 0.3767
Girder Gbottom Mpa 0 -0.016 -0.029 -0.175 -0.378 -0.4007 -0.685 -0.8554 -0.9108
F) Stresses due to Live load (Without SV) Load factor = 0.2
Dtop Mpa 0 0.0151 0.0295 0.1647 0.3087 0.342 0.546 0.64526 0.7056
Deck Dbottom Mpa 0 0.012 0.0234 0.1277 0.2327 0.2577 0.411 0.48628 0.5318
Gtop Mpa 0 0.012 0.0234 0.1277 0.2327 0.2577 0.411 0.48628 0.5318
Girder Gbottom Mpa 0 -0.02 -0.04 -0.258 -0.563 -0.6232 -0.994 -1.17578 -1.2857

EPC Contractor-M/s Krishna Constructions 126


Design ch-109+720
Design of PSC Girder

F.1) Stresses due to Live load (With SV) Load factor = 0.2
Dtop Mpa 0 0.0098 0.0199 0.1138 0.2155 0.2298 0.406 0.5305 0.5487
Deck Dbottom Mpa 0 0.0078 0.0158 0.0883 0.1624 0.1732 0.306 0.39979 0.4135
Gtop Mpa 0 0.0078 0.0158 0.0883 0.1624 0.1732 0.306 0.39979 0.4135
Girder Gbottom Mpa 0 -0.013 -0.027 -0.179 -0.393 -0.4188 -0.741 -0.96666 -0.9997
G) Stresses due to differential shrinkage Load factor = 1
Dtop Mpa -0.713 -0.713 -0.713 -0.635 -0.477 -0.4765 -0.477 -0.47654 -0.4765
Deck Dbottom Mpa -0.875 -0.875 -0.875 -0.803 -0.652 -0.6523 -0.652 -0.65231 -0.6523
Gtop Mpa 1.1035 1.1035 1.1035 1.1759 1.3266 1.3266 1.327 1.32662 1.3266
Girder Gbottom Mpa -0.592 -0.592 -0.592 -0.58 -0.511 -0.511 -0.511 -0.511 -0.511
H) -ve temperature stresses Load factor = 0.6
Dtop Mpa -1.699 -1.699 -1.699 -1.643 -1.588 -1.5877 -1.588 -1.58772 -1.5877
Deck Dbottom Mpa 0.3901 0.3901 0.3901 0.4567 0.524 0.524 0.524 0.52397 0.524
Gtop Mpa 0.3901 0.3901 0.3901 0.4567 0.524 0.524 0.524 0.52397 0.524
Girder Gbottom Mpa -1.907 -1.907 -1.907 -1.724 -1.538 -1.5383 -1.538 -1.53827 -1.5383
Total Stresses (A+B +C+D+E+F+G) (Without SV Loading)
Dtop Mpa -2.412 -2.385 -2.361 -2.002 -1.548 -1.5024 -1.143 -0.94955 -0.8588
Deck Dbottom Mpa -0.485 -0.464 -0.445 -0.132 0.2606 0.2951 0.566 0.71173 0.7801
Gtop Mpa 2.2787 2.3342 2.3602 3.7108 6.5889 6.6149 7.247 7.85 8.3526
Girder Gbottom Mpa 5.8382 5.7704 5.7333 7.4012 10.345 10.284 9.531 8.97884 8.525
Total Stresses (A+B +C+D+E+F+G) (With SV Loading)
Dtop Mpa -0.713 -0.692 -0.672 -0.409 -0.054 -0.0268 0.306 0.52341 0.572
Deck Dbottom Mpa -0.875 -0.859 -0.843 -0.628 -0.334 -0.3134 -0.063 0.10127 0.1379
Gtop Mpa 1.8886 1.9399 1.9625 3.2147 5.9947 6.0064 6.619 7.23954 7.7104
Girder Gbottom Mpa 7.7455 7.6849 7.6535 9.2046 12.053 12.026 11.32 10.7262 10.349

Max Compressive stress = 12.053 Mpa < 24 Mpa OK


Max Tensile Stress = 1.8886 Mpa >= -3.516 Mpa OK

SUMMARY FOR SLS FREQUENT COMBINATION


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
1) Frequent Combination LC-SF1 : At day 92 Structure open to LL
Total Stresses (A+B)
Gtop Mpa 1.0103 1.0776 1.1163 2.4903 5.3993 5.4578 6.078 6.66112 7.2459
Girder Gbottom Mpa 9.3954 9.294 9.2236 10.753 13.891 13.705 12.41 11.6418 10.966
1.1) Frequent Combination LC-SF1.1 : At day 92 Structure open to LL + temperature stresses
Total Stresses (A+B)
Gtop Mpa 0.3504 0.4177 0.4564 1.8923 4.8636 4.9222 5.543 6.12551 6.7103
Girder Gbottom Mpa 10.798 10.697 10.626 11.927 14.835 14.648 13.36 12.5854 11.909
1.2) Frequent Combination LC-SF1.2 : At day 92 Structure open to LL - temperature stresses
Total Stresses (A+B)
Gtop Mpa 1.3354 1.4027 1.4413 2.871 5.8359 5.8944 6.515 7.09776 7.6825
Girder Gbottom Mpa 7.806 7.7046 7.6342 9.3165 12.609 12.423 11.13 10.3599 9.6838
1.3) Frequent Combination LC-SF1.3 : At day 92 Structure open to LL + temperature stresses
Total Stresses (A+B)
Gtop Mpa 0.2184 0.2529 0.26 1.4214 4.1167 4.1063 4.305 4.68111 5.1408
Girder Gbottom Mpa 11.079 11.034 11.017 12.873 16.57 16.551 16.28 16.0075 15.634
1.4) Frequent Combination LC-SF1.4 : At day 92 Structure open to LL - temperature stresses
Total Stresses (A+B)
Gtop Mpa 1.4004 1.4349 1.442 2.5958 5.2834 5.273 5.472 5.84781 6.3075
Girder Gbottom Mpa 7.4881 7.443 7.4265 9.7398 13.9 13.88 13.61 13.3369 12.963
2) Frequent Combination LC-SF2 : At day 36500
Total Stresses (A+B)
Gtop Mpa 1.8886 1.9769 2.0344 3.6054 6.7048 6.7997 7.854 8.66331 9.291
Girder Gbottom Mpa 7.7455 7.6214 7.5304 8.4143 10.336 10.108 8.336 7.28371 6.5275

EPC Contractor-M/s Krishna Constructions 127


Design ch-109+720
Design of PSC Girder

2.1) Frequent Combination LC-SF2.1 : At day 36500 + temperature stresses


Total Stresses (A+B)
Gtop Mpa 1.2287 1.317 1.3745 3.0073 6.1692 6.264 7.318 8.1277 8.7554
Girder Gbottom Mpa 9.1484 9.0243 8.9332 9.5886 11.28 11.052 9.279 8.22729 7.4711
2.2) Frequent Combination LC-S2.2 : At day 36500 - temperature stresses
Total Stresses (A+B)
Gtop Mpa 2.2137 2.302 2.3595 3.986 7.1414 7.2363 8.291 9.09995 9.7276
Girder Gbottom Mpa 6.1561 6.032 5.9409 6.9779 9.0545 8.8263 7.054 6.00182 5.2456
2.3) Frequent Combination LC-SF2.3 : At day 36500 + temperature stresses
Total Stresses (A+B)
Gtop Mpa 1.0967 1.1522 1.1782 2.5365 5.4222 5.4482 6.081 6.6833 7.1859
Girder Gbottom Mpa 9.429 9.3612 9.324 10.534 13.016 12.954 12.2 11.6494 11.196
2.4) Frequent Combination LC-SF2.4 : At day 36500 - temperature stresses
Total Stresses (A+B)
Gtop Mpa 2.2787 2.3342 2.3602 3.7108 6.5889 6.6149 7.247 7.85 8.3526
Girder Gbottom Mpa 5.8382 5.7704 5.7333 7.4012 10.345 10.284 9.531 8.97884 8.525

QUASI PERMANENT LOAD COMBINATION


1) QSP Combination LC-SQ1 : At day 92 Structure open to LL
Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.7533 0.5473 0.3666 -0.53 -0.482 -0.7734 -4.349 -6.25093 -6.5622
Girder Gbottom Mpa 9.5277 9.7449 9.9351 14.245 21.051 21.362 25.26 27.4856 27.983

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.788 5.95593 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.8538 -4.808 -5.98034 -6.3712

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.491 4.45644 4.7698
Girder Gbottom Mpa 0.0017 -0.098 -0.164 -0.88 -1.851 -1.9424 -3.505 -4.4747 -4.7893

D) Stresses due to transfer over permanent


Load
bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0115 0.0211 0.1118 0.2074 0.2199 0.376 0.46944 0.4999
Deck Dbottom Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.283 0.35378 0.3767
Gtop Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.283 0.35378 0.3767
Girder Gbottom Mpa 0 -0.016 -0.029 -0.175 -0.378 -0.4007 -0.685 -0.8554 -0.9108
F) Stresses due to Live load Load factor = 0
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0

EPC Contractor-M/s Krishna Constructions 128


Design ch-109+720
Design of PSC Girder

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.173 -0.173 -0.173 -0.154 -0.116 -0.1158 -0.116 -0.11579 -0.1158
Deck Dbottom Mpa -0.213 -0.213 -0.213 -0.195 -0.158 -0.1585 -0.158 -0.15849 -0.1585
Gtop Mpa 0.2681 0.2681 0.2681 0.2857 0.3223 0.3223 0.322 0.32233 0.3223
Girder Gbottom Mpa -0.144 -0.144 -0.144 -0.141 -0.124 -0.1242 -0.124 -0.12416 -0.1242
Total Stresses (A+B +C+D+E+F+G)
Dtop Mpa -0.173 -0.162 -0.152 -0.043 0.0916 0.1041 0.26 0.35366 0.3841
Deck Dbottom Mpa -0.213 -0.204 -0.196 -0.108 -0.002 0.0072 0.125 0.19529 0.2182
Gtop Mpa 1.0103 1.0328 1.0285 2.0113 4.5268 4.4913 4.536 4.83756 5.2518
Girder Gbottom Mpa 9.3954 9.3708 9.3739 11.722 16.001 16.041 16.14 16.051 15.787

Max Compressive stress = 16.14 Mpa < 18 Mpa OK


Max Tensile Stress = 1.0103 Mpa >= -3.516 Mpa OK

1.1) QSP Combination LC-SQ1.1 : At day 92 Structure open to LL + temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.7533 0.5473 0.3666 -0.53 -0.482 -0.7734 -4.349 -6.25093 -6.5622
Girder Gbottom Mpa 9.5277 9.7449 9.9351 14.245 21.051 21.362 25.26 27.4856 27.983

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.788 5.95593 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.8538 -4.808 -5.98034 -6.3712

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.491 4.45644 4.7698
Girder Gbottom Mpa 0.0017 -0.098 -0.164 -0.88 -1.851 -1.9424 -3.505 -4.4747 -4.7893

D) Stresses due to transfer over permanent


Load
bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0115 0.0211 0.1118 0.2074 0.2199 0.376 0.46944 0.4999
Deck Dbottom Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.283 0.35378 0.3767
Gtop Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.283 0.35378 0.3767
Girder Gbottom Mpa 0 -0.016 -0.029 -0.175 -0.378 -0.4007 -0.685 -0.8554 -0.9108
F) Stresses due to Live load Load factor = 0
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.173 -0.173 -0.173 -0.154 -0.116 -0.1158 -0.116 -0.11579 -0.1158
Deck Dbottom Mpa -0.213 -0.213 -0.213 -0.195 -0.158 -0.1585 -0.158 -0.15849 -0.1585
Gtop Mpa 0.2681 0.2681 0.2681 0.2857 0.3223 0.3223 0.322 0.32233 0.3223
Girder Gbottom Mpa -0.144 -0.144 -0.144 -0.141 -0.124 -0.1242 -0.124 -0.12416 -0.1242

EPC Contractor-M/s Krishna Constructions 129


Design ch-109+720
Design of PSC Girder

H) +ve temperature stresses Load factor = 0.5


Dtop Mpa 2.26 2.26 2.26 2.3498 2.4404 2.4404 2.44 2.4404 2.4404
Deck Dbottom Mpa -0.66 -0.66 -0.66 -0.598 -0.536 -0.5356 -0.536 -0.53561 -0.5356
Gtop Mpa -0.66 -0.66 -0.66 -0.598 -0.536 -0.5356 -0.536 -0.53561 -0.5356
Girder Gbottom Mpa 1.4029 1.4029 1.4029 1.1743 0.9436 0.9436 0.944 0.94358 0.9436
Total Stresses (A+B +C+D+E+F+G)
Dtop Mpa 2.0867 2.0981 2.1078 2.3073 2.532 2.5445 2.701 2.79406 2.8245
Deck Dbottom Mpa -0.873 -0.864 -0.856 -0.706 -0.538 -0.5284 -0.411 -0.34032 -0.3174
Gtop Mpa 0.3504 0.3729 0.3686 1.4133 3.9912 3.9557 4.001 4.30195 4.7162
Girder Gbottom Mpa 10.798 10.774 10.777 12.896 16.944 16.985 17.08 16.9946 16.731

Max Compressive stress = 17.084 Mpa < 18 Mpa OK


Max Tensile Stress = 0.3504 Mpa >= -3.516 Mpa OK

1.2) QSP Combination LC-SQ1.2 : At day 92 Structure open to LL - temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.7533 0.5473 0.3666 -0.53 -0.482 -0.7734 -4.349 -6.25093 -6.5622
Girder Gbottom Mpa 9.5277 9.7449 9.9351 14.245 21.051 21.362 25.26 27.4856 27.983

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.788 5.95593 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.8538 -4.808 -5.98034 -6.3712

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.491 4.45644 4.7698
Girder Gbottom Mpa 0.0017 -0.098 -0.164 -0.88 -1.851 -1.9424 -3.505 -4.4747 -4.7893

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0115 0.0211 0.1118 0.2074 0.2199 0.376 0.46944 0.4999
Deck Dbottom Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.283 0.35378 0.3767
Gtop Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.283 0.35378 0.3767
Girder Gbottom Mpa 0 -0.016 -0.029 -0.175 -0.378 -0.4007 -0.685 -0.8554 -0.9108
F) Stresses due to Live load Load factor = 0
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
G) Stresses due to differential shrinkage Load factor = 1
Dtop Mpa -0.173 -0.173 -0.173 -0.154 -0.116 -0.1158 -0.116 -0.11579 -0.1158
Deck Dbottom Mpa -0.213 -0.213 -0.213 -0.195 -0.158 -0.1585 -0.158 -0.15849 -0.1585
Gtop Mpa 0.2681 0.2681 0.2681 0.2857 0.3223 0.3223 0.322 0.32233 0.3223
Girder Gbottom Mpa -0.144 -0.144 -0.144 -0.141 -0.124 -0.1242 -0.124 -0.12416 -0.1242

EPC Contractor-M/s Krishna Constructions 130


Design ch-109+720
Design of PSC Girder

H) -ve temperature stresses Load factor = 0.5


Dtop Mpa -1.416 -1.416 -1.416 -1.37 -1.323 -1.3231 -1.323 -1.3231 -1.3231
Deck Dbottom Mpa 0.3251 0.3251 0.3251 0.3806 0.4366 0.4366 0.437 0.43664 0.4366
Gtop Mpa 0.3251 0.3251 0.3251 0.3806 0.4366 0.4366 0.437 0.43664 0.4366
Girder Gbottom Mpa -1.589 -1.589 -1.589 -1.436 -1.282 -1.2819 -1.282 -1.28189 -1.2819
Total Stresses (A+B +C+D+E+F+G)
Dtop Mpa -1.589 -1.577 -1.568 -1.412 -1.231 -1.219 -1.063 -0.96944 -0.939
Deck Dbottom Mpa 0.1124 0.1215 0.1292 0.2722 0.4344 0.4439 0.561 0.63193 0.6549
Gtop Mpa 1.3354 1.3579 1.3536 2.392 4.9634 4.9279 4.973 5.2742 5.6885
Girder Gbottom Mpa 7.806 7.7813 7.7844 10.286 14.719 14.76 14.86 14.7691 14.505

Max Compressive stress = 14.858 Mpa < 18 Mpa OK


Max Tensile Stress = 1.3354 Mpa >= -3.516 Mpa OK

2) QSP Combination LC-SQ2 : At day 36500


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.7963 0.6113 0.4494 -0.305 -0.181 -0.4358 -3.577 -5.25302 -5.5213
Girder Gbottom Mpa 8.3259 8.5203 8.6899 12.346 17.884 18.153 21.57 23.5143 23.931

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.788 5.95593 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.8538 -4.808 -5.98034 -6.3712

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.491 4.45644 4.7698
Girder Gbottom Mpa 0.0017 -0.098 -0.164 -0.88 -1.851 -1.9424 -3.505 -4.4747 -4.7893

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.1) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.2) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0115 0.0211 0.1118 0.2074 0.2199 0.376 0.46944 0.4999
Deck Dbottom Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.283 0.35378 0.3767
Gtop Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.283 0.35378 0.3767
Girder Gbottom Mpa 0 -0.016 -0.029 -0.175 -0.378 -0.4007 -0.685 -0.8554 -0.9108
F) Stresses due to Live load Load factor = 0
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
G) Stresses due to differential shrinkage Load factor = 1
Dtop Mpa -0.713 -0.713 -0.713 -0.635 -0.477 -0.4765 -0.477 -0.47654 -0.4765
Deck Dbottom Mpa -0.875 -0.875 -0.875 -0.803 -0.652 -0.6523 -0.652 -0.65231 -0.6523
Gtop Mpa 1.1035 1.1035 1.1035 1.1759 1.3266 1.3266 1.327 1.32662 1.3266
Girder Gbottom Mpa -0.592 -0.592 -0.592 -0.58 -0.511 -0.511 -0.511 -0.511 -0.511

EPC Contractor-M/s Krishna Constructions 131


Design ch-109+720
Design of PSC Girder

Total Stresses (A+B +C+D+E+F+G)


Dtop Mpa -0.713 -0.702 -0.692 -0.523 -0.269 -0.2566 -0.101 -0.00709 0.0233
Deck Dbottom Mpa -0.875 -0.866 -0.859 -0.716 -0.496 -0.4866 -0.369 -0.29853 -0.2756
Gtop Mpa 1.8886 1.9321 1.9466 3.1264 5.8323 5.8332 6.312 6.83975 7.2969
Girder Gbottom Mpa 7.7455 7.6982 7.6806 9.3833 12.446 12.445 12.06 11.6929 11.349

Max Compressive stress = 12.446 Mpa < 18 Mpa OK


Max Tensile Stress = 1.8886 Mpa >= -3.516 Mpa OK

2.1) QSP Combination LC-SQ2.1 : At day 36500 + temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.7963 0.6113 0.4494 -0.305 -0.181 -0.4358 -3.577 -5.25302 -5.5213
Girder Gbottom Mpa 8.3259 8.5203 8.6899 12.346 17.884 18.153 21.57 23.5143 23.931

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.788 5.95593 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.8538 -4.808 -5.98034 -6.3712

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.491 4.45644 4.7698
Girder Gbottom Mpa 0.0017 -0.098 -0.164 -0.88 -1.851 -1.9424 -3.505 -4.4747 -4.7893

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.1) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.2) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0115 0.0211 0.1118 0.2074 0.2199 0.376 0.46944 0.4999
Deck Dbottom Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.283 0.35378 0.3767
Gtop Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.283 0.35378 0.3767
Girder Gbottom Mpa 0 -0.016 -0.029 -0.175 -0.378 -0.4007 -0.685 -0.8554 -0.9108
F) Stresses due to Live load Load factor = 0
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
G) Stresses due to differential shrinkage Load factor = 1
Dtop Mpa -0.713 -0.713 -0.713 -0.635 -0.477 -0.4765 -0.477 -0.47654 -0.4765
Deck Dbottom Mpa -0.875 -0.875 -0.875 -0.803 -0.652 -0.6523 -0.652 -0.65231 -0.6523
Gtop Mpa 1.1035 1.1035 1.1035 1.1759 1.3266 1.3266 1.327 1.32662 1.3266
Girder Gbottom Mpa -0.592 -0.592 -0.592 -0.58 -0.511 -0.511 -0.511 -0.511 -0.511
H) +ve temperature stresses Load factor = 0.5
Dtop Mpa 2.26 2.26 2.26 2.3498 2.4404 2.4404 2.44 2.4404 2.4404
Deck Dbottom Mpa -0.66 -0.66 -0.66 -0.598 -0.536 -0.5356 -0.536 -0.53561 -0.5356
Gtop Mpa -0.66 -0.66 -0.66 -0.598 -0.536 -0.5356 -0.536 -0.53561 -0.5356
Girder Gbottom Mpa 1.4029 1.4029 1.4029 1.1743 0.9436 0.9436 0.944 0.94358 0.9436

EPC Contractor-M/s Krishna Constructions 132


Design ch-109+720
Design of PSC Girder

Total Stresses (A+B +C+D+E+F+G)


Dtop Mpa 1.5467 1.5582 1.5678 1.8265 2.1712 2.1838 2.34 2.43331 2.4637
Deck Dbottom Mpa -1.535 -1.526 -1.519 -1.314 -1.032 -1.0222 -0.905 -0.83414 -0.8112
Gtop Mpa 1.2287 1.2722 1.2867 2.5283 5.2967 5.2975 5.777 6.30414 6.7613
Girder Gbottom Mpa 9.1484 9.101 9.0835 10.558 13.389 13.389 13.01 12.6365 12.293

Max Compressive stress = 13.389 Mpa < 18 Mpa OK


Max Tensile Stress = 1.2287 Mpa >= -3.516 Mpa OK

2.2) QSP Combination LC-SQ2.2 : At day 36500 - temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.7963 0.6113 0.4494 -0.305 -0.181 -0.4358 -3.577 -5.25302 -5.5213
Girder Gbottom Mpa 8.3259 8.5203 8.6899 12.346 17.884 18.153 21.57 23.5143 23.931

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.788 5.95593 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.8538 -4.808 -5.98034 -6.3712

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.491 4.45644 4.7698
Girder Gbottom Mpa 0.0017 -0.098 -0.164 -0.88 -1.851 -1.9424 -3.505 -4.4747 -4.7893

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.1) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.2) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0115 0.0211 0.1118 0.2074 0.2199 0.376 0.46944 0.4999
Deck Dbottom Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.283 0.35378 0.3767
Gtop Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.283 0.35378 0.3767
Girder Gbottom Mpa 0 -0.016 -0.029 -0.175 -0.378 -0.4007 -0.685 -0.8554 -0.9108
F) Stresses due to Live load Load factor = 0
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
G) Stresses due to differential shrinkage Load factor = 1
Dtop Mpa -0.713 -0.713 -0.713 -0.635 -0.477 -0.4765 -0.477 -0.47654 -0.4765
Deck Dbottom Mpa -0.875 -0.875 -0.875 -0.803 -0.652 -0.6523 -0.652 -0.65231 -0.6523
Gtop Mpa 1.1035 1.1035 1.1035 1.1759 1.3266 1.3266 1.327 1.32662 1.3266
Girder Gbottom Mpa -0.592 -0.592 -0.592 -0.58 -0.511 -0.511 -0.511 -0.511 -0.511
H) -ve temperature stresses Load factor = 0.5
Dtop Mpa -1.416 -1.416 -1.416 -1.37 -1.323 -1.3231 -1.323 -1.3231 -1.3231
Deck Dbottom Mpa 0.3251 0.3251 0.3251 0.3806 0.4366 0.4366 0.437 0.43664 0.4366
Gtop Mpa 0.3251 0.3251 0.3251 0.3806 0.4366 0.4366 0.437 0.43664 0.4366
Girder Gbottom Mpa -1.589 -1.589 -1.589 -1.436 -1.282 -1.2819 -1.282 -1.28189 -1.2819

EPC Contractor-M/s Krishna Constructions 133


Design ch-109+720
Design of PSC Girder

Total Stresses (A+B +C+D+E+F+G)


Dtop Mpa -2.129 -2.117 -2.108 -1.893 -1.592 -1.5797 -1.424 -1.33019 -1.2998
Deck Dbottom Mpa -0.55 -0.541 -0.534 -0.336 -0.059 -0.0499 0.068 0.13812 0.161
Gtop Mpa 2.2137 2.2572 2.2717 3.507 6.269 6.2698 6.749 7.27639 7.7336
Girder Gbottom Mpa 6.1561 6.1087 6.0912 7.9469 11.164 11.163 10.78 10.411 10.067

Max Compressive stress = 11.164 Mpa < 18 Mpa OK


Max Tensile Stress = 2.2137 Mpa >= -3.516 Mpa OK

SUMMARY FOR SLS QUASI PERMANENT LOAD COMBINATION


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
1) QSP Combination LC-SQ1 : At day 92 Structure open to LL
Total Stresses (A+B)
Gtop Mpa 1.0103 1.0328 1.0285 2.0113 4.5268 4.4913 4.536 4.83756 5.2518
Girder Gbottom Mpa 9.3954 9.3708 9.3739 11.722 16.001 16.041 16.14 16.051 15.787
2) QSP Combination LC-SQ2 : At day 36500
Total Stresses (A+B)
Gtop Mpa 1.8886 1.9321 1.9466 3.1264 5.8323 5.8332 6.312 6.83975 7.2969
Girder Gbottom Mpa 7.7455 7.6982 7.6806 9.3833 12.446 12.445 12.06 11.6929 11.349
1.1) QSP Combination LC-SQ1.1 : At day 92 Structure open to LL + temperature stresses
Total Stresses (A+B)
Gtop Mpa 0.3504 0.3729 0.3686 1.4133 3.9912 3.9557 4.001 4.30195 4.7162
Girder Gbottom Mpa 10.798 10.774 10.777 12.896 16.944 16.985 17.08 16.9946 16.731
2.1) QSP Combination LC-SQ2.1 : At day 36500 + temperature stresses
Total Stresses (A+B)
Gtop Mpa 1.2287 1.2722 1.2867 2.5283 5.2967 5.2975 5.777 6.30414 6.7613
Girder Gbottom Mpa 9.1484 9.101 9.0835 10.558 13.389 13.389 13.01 12.6365 12.293
1.2) QSP Combination LC-SQ1.2 : At day 92 Structure open to LL - temperature stresses
Total Stresses (A+B)
Gtop Mpa 1.3354 1.3579 1.3536 2.392 4.9634 4.9279 4.973 5.2742 5.6885
Girder Gbottom Mpa 7.806 7.7813 7.7844 10.286 14.719 14.76 14.86 14.7691 14.505
2.2) QSP Combination LC-SQ2.2 : At day 36500 - temperature stresses
Total Stresses (A+B)
Gtop Mpa 2.2137 2.2572 2.2717 3.507 6.269 6.2698 6.749 7.27639 7.7336
Girder Gbottom Mpa 6.1561 6.1087 6.0912 7.9469 11.164 11.163 10.78 10.411 10.067

EPC Contractor-M/s Krishna Constructions 134


Design ch-109+720
Design of PSC Girder

CHECK FOR STRESSES : PRESTRESS WITH INFERIOR LOAD COMBINATION

SLS STRESS CHECK : RARE COMBINATION INFERIOR


A) OUTER GIRDER SUMMARY OF LOADS
BENDING MOMENT SUMMARY
Section At unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
Precast Beam Tm -0 -0.054 -0.73 8.6895 16.778 84.646 142.08 150.3 253.22 314.97 335.5
Deck Outer Girder Tm -0.04 0.1364 -0.129 7.3472 12.252 56.169 97.493 102.3 184.62 235.67 252.2
Transfer brg. Tm 0 0 0 0 0 0 0 0 0 0 0
SIDL Tm 0 0 0 0 0 0 0 0 0 0 0
Surfacing Tm 0 0 0 1.672 3.079 15.56 27.248 28.893 49.39 61.68 65.68
Wind Load T 0 0 0 1.646 3.032 15.321 26.828 28.448 48.63 60.731 64.67
Live Load (Without SV Loading) Tm 0 0 0 10.965 21.471 114.62 202.82 224.67 358.41 423.91 463.5
Live Load (With SV Loading) Tm 0 0 0 7.128 14.513 79.248 141.54 150.99 267 348.51 360.4

SECTION PROPERTIES
Sections unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Section at m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
Properties of Precast Section
Area m2 1.9297 1.9297 1.9297 1.9297 1.9297 1.4394 0.9447 0.9447 0.9447 0.9447 0.945
I gross m4 0.872 0.872 0.872 0.872 0.872 0.7401 0.6069 0.6069 0.6069 0.6069 0.607
yb m 1.1677 1.1677 1.1677 1.1677 1.1677 1.16 1.1524 1.1524 1.1524 1.1524 1.152
yt m 1.1323 1.1323 1.1323 1.1323 1.1323 1.14 1.1476 1.1476 1.1476 1.1476 1.148
Properties of Composite Section
Area m2 2.5025 2.5025 2.5025 2.5025 2.5025 2.0122 1.5175 1.5175 1.5175 1.5175 1.517
I gross m4 1.556 1.556 1.556 1.556 1.556 1.3655 1.1732 1.1732 1.1732 1.1732 1.173
yb m 1.452 1.452 1.452 1.452 1.452 1.5391 1.6271 1.6271 1.6271 1.6271 1.627
yt m 1.068 1.068 1.068 1.068 1.068 0.9809 0.8929 0.8929 0.8929 0.8929 0.893
Gtop m 0.848 0.848 0.848 0.848 0.848 0.7609 0.6729 0.6729 0.6729 0.6729 0.673

STRESSES DUE TO ACTION OF LOADS :


Section At unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
Precast Beam
Gtop Mpa 0 -7E-04 -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.345
Girder Gbottom Mpa 0 0.0007 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.9803 -6.371

Deck Outer Girder


Gtop Mpa -5E-04 0.0018 -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.4912 4.4564 4.77
Girder Gbottom Mpa 0.0005 -0.002 0.0017 -0.098 -0.164 -0.88 -1.851 -1.942 -3.505 -4.4747 -4.789

Transfer brg.
Dtop Mpa 0 0 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0 0 0
Stresses Girder
At Gbottom Mpa 0 0 0 0 0 0 0 0 0 0 0

SIDL
Dtop Mpa 0 0 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0 0 0
Stresses Girder
At Gbottom Mpa 0 0 0 0 0 0 0 0 0 0 0

Section At unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
Surfacing
Dtop Mpa 0 0 0 0.0115 0.0211 0.1118 0.2074 0.2199 0.3759 0.4694 0.5
Deck Dbottom Mpa 0 0 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.2833 0.3538 0.377
Gtop Mpa 0 0 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.2833 0.3538 0.377
Stresses Girder
At Gbottom Mpa 0 0 0 -0.016 -0.029 -0.175 -0.378 -0.401 -0.685 -0.8554 -0.911

Live Load (Without SV Loading)

EPC Contractor-M/s Krishna Constructions 135


Design ch-109+720
Design of PSC Girder

Dtop Mpa 0 0 0 0.0753 0.1474 0.8233 1.5436 1.71 2.7278 3.2263 3.528
Deck Dbottom Mpa 0 0 0 0.0598 0.117 0.6387 1.1633 1.2887 2.0557 2.4314 2.659
Gtop Mpa 0 0 0 0.0598 0.117 0.6387 1.1633 1.2887 2.0557 2.4314 2.659
Stresses Girder
At Gbottom Mpa 0 0 0 -0.102 -0.2 -1.292 -2.813 -3.116 -4.971 -5.8789 -6.429

Live Load (With SV Loading)


Dtop Mpa 0 0 0 0.0489 0.0996 0.5692 1.0773 1.1492 2.0321 2.6525 2.743
Deck Dbottom Mpa 0 0 0 0.0388 0.0791 0.4416 0.8118 0.866 1.5314 1.999 2.067
Gtop Mpa 0 0 0 0.0388 0.0791 0.4416 0.8118 0.866 1.5314 1.999 2.067
Stresses Girder
At Gbottom Mpa 0 0 0 -0.067 -0.135 -0.893 -1.963 -2.094 -3.703 -4.8333 -4.999

Wind Load
Dtop Mpa 0 0 0 0.0113 0.0208 0.1101 0.2042 0.2165 0.3701 0.4622 0.492
Deck Dbottom Mpa 0 0 0 0.009 0.0165 0.0854 0.1539 0.1632 0.2789 0.3483 0.371
Gtop Mpa 0 0 0 0.009 0.0165 0.0854 0.1539 0.1632 0.2789 0.3483 0.371
Stresses Girder
At Gbottom Mpa 0 0 0 -0.015 -0.028 -0.173 -0.372 -0.395 -0.674 -0.8422 -0.897

STRESSES DUE TO DIFFERENTIAL SHRINKAGE :


At day 63
Dtop Mpa -0.182 -0.182 -0.182 -0.182 -0.182 -0.162 -0.122 -0.122 -0.122 -0.1219 -0.122
Deck Dbottom Mpa -0.224 -0.224 -0.224 -0.224 -0.224 -0.205 -0.167 -0.167 -0.167 -0.1668 -0.167
Gtop Mpa 0.2822 0.2822 0.2822 0.2822 0.2822 0.3008 0.3393 0.3393 0.3393 0.3393 0.339
Stresses Girder
At Gbottom Mpa -0.151 -0.151 -0.151 -0.151 -0.151 -0.148 -0.131 -0.131 -0.131 -0.1307 -0.131

At day 64
Dtop Mpa -0.182 -0.182 -0.182 -0.182 -0.182 -0.162 -0.122 -0.122 -0.122 -0.1218 -0.122
Deck Dbottom Mpa -0.224 -0.224 -0.224 -0.224 -0.224 -0.205 -0.167 -0.167 -0.167 -0.1668 -0.167
Gtop Mpa 0.2821 0.2821 0.2821 0.2821 0.2821 0.3007 0.3392 0.3392 0.3392 0.3392 0.339
Stresses Girder
At Gbottom Mpa -0.151 -0.151 -0.151 -0.151 -0.151 -0.148 -0.131 -0.131 -0.131 -0.1306 -0.131

At day 92
Dtop Mpa -0.173 -0.173 -0.173 -0.173 -0.173 -0.154 -0.116 -0.116 -0.116 -0.1158 -0.116
Deck Dbottom Mpa -0.213 -0.213 -0.213 -0.213 -0.213 -0.195 -0.158 -0.158 -0.158 -0.1585 -0.158
Gtop Mpa 0.2681 0.2681 0.2681 0.2681 0.2681 0.2857 0.3223 0.3223 0.3223 0.3223 0.322
Stresses Girder
At Gbottom Mpa -0.144 -0.144 -0.144 -0.144 -0.144 -0.141 -0.124 -0.124 -0.124 -0.1242 -0.124

At day 36500
Dtop Mpa -0.713 -0.713 -0.713 -0.713 -0.713 -0.635 -0.477 -0.477 -0.477 -0.4765 -0.477
Deck Dbottom Mpa -0.875 -0.875 -0.875 -0.875 -0.875 -0.803 -0.652 -0.652 -0.652 -0.6523 -0.652
Gtop Mpa 1.1035 1.1035 1.1035 1.1035 1.1035 1.1759 1.3266 1.3266 1.3266 1.3266 1.327
Stresses Girder
At Gbottom Mpa -0.592 -0.592 -0.592 -0.592 -0.592 -0.58 -0.511 -0.511 -0.511 -0.511 -0.511

STRESSES DUE TO +VE TEMPERATURE STRESSES :


Section At unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
Dtop Mpa 4.52 4.52 4.52 4.6996 4.8808 4.8808 4.8808 4.8808 4.881
Deck Dbottom Mpa -1.32 -1.32 -1.32 -1.196 -1.071 -1.071 -1.071 -1.0712 -1.071
Gtop Mpa -1.32 -1.32 -1.32 -1.196 -1.071 -1.071 -1.071 -1.0712 -1.071
Stresses Girder
At Gbottom Mpa 2.8058 2.8058 2.8058 2.3486 1.8872 1.8872 1.8872 1.8872 1.887
STRESSES DUE TO -VE TEMPERATURE STRESSES :
Dtop Mpa -2.831 -2.831 -2.831 -2.739 -2.646 -2.646 -2.646 -2.6462 -2.646
Deck Dbottom Mpa 0.6502 0.6502 0.6502 0.7612 0.8733 0.8733 0.8733 0.8733 0.873
Gtop Mpa 0.6502 0.6502 0.6502 0.7612 0.8733 0.8733 0.8733 0.8733 0.873
Stresses Girder
At Gbottom Mpa -3.179 -3.179 -3.179 -2.873 -2.564 -2.564 -2.564 -2.5638 -2.564

EPC Contractor-M/s Krishna Constructions 136


Design ch-109+720
Design of PSC Girder

STRESSES AT DIFFERENT STAGES DUE TO PRE-STRESSING FORCES :


Load factor Superior load factor = 0.9
Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Gtop At day 14 Mpa -2.653 -2.706 -2.753 -3.26 -3.34 -3.416 -4.354 -4.8627 -4.972
Girder Gbottom Mpa 8.4045 8.4616 8.5118 10.908 14.897 14.983 16.055 16.697 16.92

Gtop 14 To day 28 Mpa -2.54 -2.59 -2.634 -3.104 -3.151 -3.222 -4.106 -4.5852 -4.686
Girder Gbottom Mpa 8.0437 8.0982 8.1461 10.385 14.052 14.132 15.141 15.744 15.95

Gtop At day 28 Mpa 0.6638 0.4882 0.3338 -0.443 -0.432 -0.684 -3.768 -5.401 -5.664
Girder Gbottom Mpa 8.0633 8.2486 8.4114 12.144 18.142 18.412 21.773 23.677 24.09

Gtop 28 To day 35 Mpa 0.6125 0.4407 0.2898 -0.469 -0.446 -0.691 -3.682 -5.2593 -5.513
Girder Gbottom Mpa 7.9968 8.1774 8.3359 11.977 17.779 18.038 21.244 23.042 23.43

Girder Gtop 35 To day 63 Mpa 0.613 0.4433 0.2943 -0.449 -0.417 -0.657 -3.606 -5.171 -5.425
Gbottom Mpa 7.8696 8.0484 8.2051 11.774 17.428 17.684 20.886 22.702 23.1

Girder Gtop 63 To day 64 Mpa 0.6129 0.4432 0.2943 -0.449 -0.416 -0.656 -3.604 -5.1682 -5.423
Gbottom Mpa 7.8666 8.0453 8.2019 11.769 17.419 17.675 20.875 22.691 23.09

Girder Gtop 64 To day 92 Mpa 0.6164 0.4478 0.3 -0.434 -0.394 -0.633 -3.558 -5.1144 -5.369
Gbottom Mpa 7.7954 7.9731 8.1287 11.655 17.224 17.478 20.67 22.488 22.89

Gtop 92 To day 36500 Mpa 0.6515 0.5002 0.3677 -0.25 -0.148 -0.357 -2.927 -4.2979 -4.517
Girder Gbottom Mpa 6.8121 6.9712 7.11 10.101 14.632 14.852 17.651 19.239 19.58

RARE LOAD COMBINATIONS :


1) Rare Combination LC-SR1 : At the time of 1st stage prestress, just after ES loss of Stage -I cables
Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop At day 14 Mpa -2.653 -2.706 -2.753 -3.26 -3.34 -3.416 -4.354 -4.8627 -4.972
Girder Gbottom Mpa 8.4045 8.4616 8.5118 10.908 14.897 14.983 16.055 16.697 16.92

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.345
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.9803 -6.371

Total Stresses (A+B)


Gtop Mpa -2.663 -2.593 -2.535 -1.956 -0.653 -0.574 0.4343 1.0932 1.373
Girder Gbottom Mpa 8.4143 8.3453 8.2871 9.5813 12.2 12.129 11.247 10.717 10.55

Max Compressive stress = 12.2 Mpa < 24 Mpa OK


Max Tensile Stress = -2.663 Mpa >= -3.516 Mpa OK

2) Rare Combination LC-SR2 : At day 28 Just before II Stage prestressing


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop At day 0 Mpa -2.54 -2.59 -2.634 -3.104 -3.151 -3.222 -4.106 -4.5852 -4.686
Girder Gbottom Mpa 8.0437 8.0982 8.1461 10.385 14.052 14.132 15.141 15.744 15.95

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.345
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.9803 -6.371

EPC Contractor-M/s Krishna Constructions 137


Design ch-109+720
Design of PSC Girder

Total Stresses (A+B+C)


Gtop Mpa -2.549 -2.477 -2.416 -1.8 -0.464 -0.38 0.6822 1.3707 1.659
Girder Gbottom Mpa 8.0535 7.9819 7.9214 9.0586 11.354 11.278 10.333 9.764 9.577

Max Compressive stress = 11.354 Mpa < 24 Mpa OK


Max Tensile Stress = -2.549 Mpa >= -3.516 Mpa OK

3) Rare Combination LC-SR3 : At day 28 Just after II Stage prestressing after ES


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.6638 0.4882 0.3338 -0.443 -0.432 -0.684 -3.768 -5.401 -5.664
Girder Gbottom Mpa 8.0633 8.2486 8.4114 12.144 18.142 18.412 21.773 23.677 24.09

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.345
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.9803 -6.371

Total Stresses (A+B)


Gtop Mpa 0.6544 0.601 0.5517 0.8605 2.2543 2.1579 1.0205 0.555 0.681
Girder Gbottom Mpa 8.073 8.1323 8.1868 10.817 15.444 15.558 16.965 17.697 17.72

Max Compressive stress = 17.715 Mpa < 24 Mpa OK


Max Tensile Stress = 0.5517 Mpa >= -3.516 Mpa OK

4) Rare Combination LC-SR4 : At day 35 At the time of casting of deck slab


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.6125 0.4407 0.2898 -0.469 -0.446 -0.691 -3.682 -5.2593 -5.513
Girder Gbottom Mpa 7.9968 8.1774 8.3359 11.977 17.779 18.038 21.244 23.042 23.43

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.345
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.9803 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.4912 4.4564 4.77
Girder Gbottom Mpa 0.0017 -0.098 -0.164 -0.88 -1.851 -1.942 -3.505 -4.4747 -4.789
Total Stresses (A+B +C)
Gtop Mpa 0.6014 0.649 0.6668 1.7002 4.0839 4.0854 4.5972 5.1531 5.602
Girder Gbottom Mpa 8.0083 7.9626 7.9472 9.7702 13.231 13.242 12.93 12.587 12.27

Max Compressive stress = 13.242 Mpa < 24 Mpa OK


Max Tensile Stress = 0.6014 Mpa >= -3.516 Mpa OK

5) Rare Combination LC-SR5 : At day 63 At the time of transfer over permanent bearings
Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.613 0.4433 0.2943 -0.449 -0.417 -0.657 -3.606 -5.171 -5.425
Girder Gbottom Mpa 7.8696 8.0484 8.2051 11.774 17.428 17.684 20.886 22.702 23.1

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.345
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.9803 -6.371

EPC Contractor-M/s Krishna Constructions 138


Design ch-109+720
Design of PSC Girder

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.4912 4.4564 4.77
Girder Gbottom Mpa 0.0017 -0.098 -0.164 -0.88 -1.851 -1.942 -3.505 -4.4747 -4.789

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to differencial shrinkage Load factor = 1
Dtop Mpa -0.182 -0.182 -0.182 -0.162 -0.122 -0.122 -0.122 -0.1219 -0.122
Deck Dbottom Mpa -0.224 -0.224 -0.224 -0.205 -0.167 -0.167 -0.167 -0.1668 -0.167
Gtop Mpa 0.2822 0.2822 0.2822 0.3008 0.3393 0.3393 0.3393 0.3393 0.339
Girder Gbottom Mpa -0.151 -0.151 -0.151 -0.148 -0.131 -0.131 -0.131 -0.1307 -0.131
Total Stresses (A+B +C+D+E)
Dtop Mpa -0.182 -0.182 -0.182 -0.162 -0.122 -0.122 -0.122 -0.1219 -0.122
Deck Dbottom Mpa -0.224 -0.224 -0.224 -0.205 -0.167 -0.167 -0.167 -0.1668 -0.167
Gtop Mpa 0.8841 0.9337 0.9535 2.0208 4.4529 4.4587 5.0125 5.5807 6.029
Girder Gbottom Mpa 7.7297 7.6822 7.665 9.4182 12.749 12.757 12.442 12.116 11.81

Max Compressive stress = 12.757 Mpa < 24 Mpa OK


Max Tensile Stress = 0.8841 Mpa >= -3.516 Mpa OK

6) Rare Combination LC-SR6 : At day 64 At the time of placing of SIDL


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.6129 0.4432 0.2943 -0.449 -0.416 -0.656 -3.604 -5.1682 -5.423
Girder Gbottom Mpa 7.8666 8.0453 8.2019 11.769 17.419 17.675 20.875 22.691 23.09

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.345
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.9803 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.4912 4.4564 4.77
Girder Gbottom Mpa 0.0017 -0.098 -0.164 -0.88 -1.851 -1.942 -3.505 -4.4747 -4.789

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.1) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.2) Stresses due to placement of SurfacingLoad factor = 1
Dtop Mpa 0 0.0115 0.0211 0.1118 0.2074 0.2199 0.3759 0.4694 0.5
Deck Dbottom Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.2833 0.3538 0.377
Gtop Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.2833 0.3538 0.377
Girder Gbottom Mpa 0 -0.016 -0.029 -0.175 -0.378 -0.401 -0.685 -0.8554 -0.911

F) Stresses due to Differential shrinkage Load factor = 1


Dtop Mpa -0.182 -0.182 -0.182 -0.162 -0.122 -0.122 -0.122 -0.1218 -0.122
Deck Dbottom Mpa -0.224 -0.224 -0.224 -0.205 -0.167 -0.167 -0.167 -0.1668 -0.167
Gtop Mpa 0.2821 0.2821 0.2821 0.3007 0.3392 0.3392 0.3392 0.3392 0.339
Girder Gbottom Mpa -0.151 -0.151 -0.151 -0.148 -0.131 -0.131 -0.131 -0.1306 -0.131
G) Stresses due to wind Load factor = 0.6
Dtop Mpa 0 0.0068 0.0125 0.066 0.1225 0.1299 0.2221 0.2773 0.295
Deck Dbottom Mpa 0 0.0054 0.0099 0.0512 0.0923 0.0979 0.1674 0.209 0.223
Gtop Mpa 0 0.0054 0.0099 0.0512 0.0923 0.0979 0.1674 0.209 0.223
Girder Gbottom Mpa 0 -0.009 -0.017 -0.104 -0.223 -0.237 -0.405 -0.5053 -0.538

EPC Contractor-M/s Krishna Constructions 139


Design ch-109+720
Design of PSC Girder

Total Stresses (A+B +C+D+E+F)


Dtop Mpa -0.182 -0.171 -0.161 -0.051 0.0855 0.0981 0.2541 0.3476 0.378
Deck Dbottom Mpa -0.224 -0.215 -0.207 -0.119 -0.01 -0.001 0.1165 0.187 0.21
Gtop Mpa 0.8839 0.9427 0.9702 2.1079 4.6099 4.6252 5.2979 5.9371 6.408
Girder Gbottom Mpa 7.7268 7.6636 7.6331 9.2377 12.362 12.348 11.746 11.25 10.89
Total Stresses (A+B +C+D+E+F+G) wind downward
Dtop Mpa -0.182 -0.164 -0.149 0.0154 0.2081 0.228 0.4761 0.6249 0.673
Deck Dbottom Mpa -0.224 -0.209 -0.197 -0.067 0.0818 0.0968 0.2839 0.396 0.432
Gtop Mpa 0.8839 0.9481 0.9801 2.1591 4.7022 4.7231 5.4652 6.1461 6.631
Girder Gbottom Mpa 7.7268 7.6544 7.6162 9.1341 12.139 12.111 11.342 10.744 10.35
Total Stresses (A+B +C+D+E+F+G) wind upward
Dtop Mpa -0.182 -0.178 -0.174 -0.117 -0.037 -0.032 0.032 0.0703 0.083
Deck Dbottom Mpa -0.224 -0.22 -0.217 -0.17 -0.103 -0.099 -0.051 -0.022 -0.013
Gtop Mpa 0.8839 0.9373 0.9603 2.0567 4.5175 4.5273 5.1305 5.7281 6.186
Girder Gbottom Mpa 7.7268 7.6728 7.6501 9.3413 12.585 12.584 12.151 11.755 11.43

Max Compressive stress = 12.362 Mpa < 24 Mpa OK


Max Tensile Stress = 0.8839 Mpa >= -3.516 Mpa OK

Max Compressive stress (wind downward) = 12.139 Mpa < 24 Mpa OK


Max Tensile Stress (wind downward) = 0.8839 Mpa >= -3.516 Mpa OK

Max Compressive stress (wind upward) = 12.585 Mpa < 24 Mpa OK


Max Tensile Stress (wind upward) = 0.8839 Mpa >= -3.516 Mpa OK

7) Rare Combination LC-SR7 : At day 92 Structure open to LL


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.6164 0.4478 0.3 -0.434 -0.394 -0.633 -3.558 -5.1144 -5.369
Girder Gbottom Mpa 7.7954 7.9731 8.1287 11.655 17.224 17.478 20.67 22.488 22.89

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.345
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.9803 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.4912 4.4564 4.77
Girder Gbottom Mpa 0.0017 -0.098 -0.164 -0.88 -1.851 -1.942 -3.505 -4.4747 -4.789

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0115 0.0211 0.1118 0.2074 0.2199 0.3759 0.4694 0.5
Deck Dbottom Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.2833 0.3538 0.377
Gtop Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.2833 0.3538 0.377
Girder Gbottom Mpa 0 -0.016 -0.029 -0.175 -0.378 -0.401 -0.685 -0.8554 -0.911
F) Stresses due to Live load (Without SV) Load factor = 1
Dtop Mpa 0 0.0753 0.1474 0.8233 1.5436 1.71 2.7278 3.2263 3.528
Deck Dbottom Mpa 0 0.0598 0.117 0.6387 1.1633 1.2887 2.0557 2.4314 2.659
Gtop Mpa 0 0.0598 0.117 0.6387 1.1633 1.2887 2.0557 2.4314 2.659
Girder Gbottom Mpa 0 -0.102 -0.2 -1.292 -2.813 -3.116 -4.971 -5.8789 -6.429
F.1) Stresses due to Live load (With SV) Load factor = 1
Dtop Mpa 0 0.0489 0.0996 0.5692 1.0773 1.1492 2.0321 2.6525 2.743
Deck

EPC Contractor-M/s Krishna Constructions 140


Design ch-109+720
Design of PSC Girder

Deck Dbottom Mpa 0 0.0388 0.0791 0.4416 0.8118 0.866 1.5314 1.999 2.067
Gtop Mpa 0 0.0388 0.0791 0.4416 0.8118 0.866 1.5314 1.999 2.067
Girder Gbottom Mpa 0 -0.067 -0.135 -0.893 -1.963 -2.094 -3.703 -4.8333 -4.999
G) Stresses due to differential shrinkage Load factor = 1
Dtop Mpa -0.173 -0.173 -0.173 -0.154 -0.116 -0.116 -0.116 -0.1158 -0.116
Deck Dbottom Mpa -0.213 -0.213 -0.213 -0.195 -0.158 -0.158 -0.158 -0.1585 -0.158
Gtop Mpa 0.2681 0.2681 0.2681 0.2857 0.3223 0.3223 0.3223 0.3223 0.322
Girder Gbottom Mpa -0.144 -0.144 -0.144 -0.141 -0.124 -0.124 -0.124 -0.1242 -0.124
G) Stresses due to wind Load factor = 0.6
Dtop Mpa 0 0.0068 0.0125 0.066 0.1225 0.1299 0.2221 0.2773 0.295
Deck Dbottom Mpa 0 0.0054 0.0099 0.0512 0.0923 0.0979 0.1674 0.209 0.223
Gtop Mpa 0 0.0054 0.0099 0.0512 0.0923 0.0979 0.1674 0.209 0.223
Girder Gbottom Mpa 0 -0.009 -0.017 -0.104 -0.223 -0.237 -0.405 -0.5053 -0.538
Total Stresses (A+B +C+D+E+F+G) (Without SV Loading)
Dtop Mpa -0.173 -0.087 -0.005 0.7808 1.6352 1.8141 2.9879 3.58 3.912
Deck Dbottom Mpa -0.213 -0.144 -0.079 0.5303 1.1611 1.2959 2.1805 2.6267 2.877
Gtop Mpa 0.8733 0.993 1.0788 2.7464 5.7777 5.9206 7.3828 8.4055 9.104
Girder Gbottom Mpa 7.6631 7.4966 7.3671 7.8398 9.3604 9.0415 6.5766 5.1747 4.271
Total Stresses (A+B +C+D+E+F+G) (With SV Loading)
Dtop Mpa -0.173 -0.113 -0.053 0.5267 1.1689 1.2533 2.2922 3.0062 3.127
Deck Dbottom Mpa -0.213 -0.165 -0.117 0.3332 0.8096 0.8733 1.6562 2.1943 2.286
Gtop Mpa 0.8733 0.9721 1.0409 2.5493 5.4263 5.4979 6.8585 7.9731 8.512
Girder Gbottom Mpa 7.6631 7.5324 7.432 8.2385 10.21 10.063 7.8443 6.2203 5.701
Total Stresses (A+B +C+D+E+F+G) wind downward
Dtop Mpa -0.173 -0.08 0.0077 0.8468 1.7577 1.944 3.21 3.8573 4.207
Deck Dbottom Mpa -0.213 -0.138 -0.069 0.5815 1.2534 1.3938 2.3479 2.8357 3.1
Gtop Mpa 0.8733 0.9984 1.0888 2.7976 5.8701 6.0185 7.5502 8.6145 9.326
Girder Gbottom Mpa 7.6631 7.4874 7.3501 7.7362 9.1372 8.8047 6.1719 4.6694 3.733
Total Stresses (A+B +C+D+E+F+G) wind upward
Dtop Mpa -0.173 -0.093 -0.017 0.7148 1.5127 1.6842 2.7659 3.3026 3.617
Deck Dbottom Mpa -0.213 -0.149 -0.089 0.479 1.0688 1.198 2.0132 2.4177 2.654
Gtop Mpa 0.8733 0.9877 1.0689 2.6952 5.6854 5.8227 7.2154 8.1965 8.881
Girder Gbottom Mpa 7.6631 7.5059 7.3841 7.9434 9.5836 9.2782 6.9812 5.68 4.809

Max Compressive stress = 10.21 Mpa < 24 Mpa OK


Max Tensile Stress = 0.8733 Mpa >= -3.516 Mpa OK

Max Compressive stress (wind downward) = 9.3263 Mpa < 24 Mpa OK


Max Tensile Stress (wind downward) = 0.8733 Mpa >= -3.516 Mpa OK

Max Compressive stress (wind upward) = 9.5836 Mpa < 24 Mpa OK


Max Tensile Stress (wind upward) = 0.8733 Mpa >= -3.516 Mpa OK

7.1) Rare Combination LC-SR7.1 : At day 92 Structure open to LL + temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.6164 0.4478 0.3 -0.434 -0.394 -0.633 -3.558 -5.1144 -5.369
Girder Gbottom Mpa 7.7954 7.9731 8.1287 11.655 17.224 17.478 20.67 22.488 22.89

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.345
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.9803 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.4912 4.4564 4.77
Girder Gbottom Mpa 0.0017 -0.098 -0.164 -0.88 -1.851 -1.942 -3.505 -4.4747 -4.789

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder

EPC Contractor-M/s Krishna Constructions 141


Design ch-109+720
Design of PSC Girder

Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0


E) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0115 0.0211 0.1118 0.2074 0.2199 0.3759 0.4694 0.5
Deck Dbottom Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.2833 0.3538 0.377
Gtop Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.2833 0.3538 0.377
Girder Gbottom Mpa 0 -0.016 -0.029 -0.175 -0.378 -0.401 -0.685 -0.8554 -0.911
F) Stresses due to Live load (Without SV) Load factor = 1
Dtop Mpa 0 0.0753 0.1474 0.8233 1.5436 1.71 2.7278 3.2263 3.528
Deck Dbottom Mpa 0 0.0598 0.117 0.6387 1.1633 1.2887 2.0557 2.4314 2.659
Gtop Mpa 0 0.0598 0.117 0.6387 1.1633 1.2887 2.0557 2.4314 2.659
Girder Gbottom Mpa 0 -0.102 -0.2 -1.292 -2.813 -3.116 -4.971 -5.8789 -6.429
F.1) Stresses due to Live load (With SV) Load factor = 1
Dtop Mpa 0 0.0489 0.0996 0.5692 1.0773 1.1492 2.0321 2.6525 2.743
Deck Dbottom Mpa 0 0.0388 0.0791 0.4416 0.8118 0.866 1.5314 1.999 2.067
Gtop Mpa 0 0.0388 0.0791 0.4416 0.8118 0.866 1.5314 1.999 2.067
Girder Gbottom Mpa 0 -0.067 -0.135 -0.893 -1.963 -2.094 -3.703 -4.8333 -4.999
G) Stresses due to differential shrinkage Load factor = 1
Dtop Mpa -0.173 -0.173 -0.173 -0.154 -0.116 -0.116 -0.116 -0.1158 -0.116
Deck Dbottom Mpa -0.213 -0.213 -0.213 -0.195 -0.158 -0.158 -0.158 -0.1585 -0.158
Gtop Mpa 0.2681 0.2681 0.2681 0.2857 0.3223 0.3223 0.3223 0.3223 0.322
Girder Gbottom Mpa -0.144 -0.144 -0.144 -0.141 -0.124 -0.124 -0.124 -0.1242 -0.124

H) +ve temperature stresses Load factor = 0.6


Dtop Mpa 2.712 2.712 2.712 2.8197 2.9285 2.9285 2.9285 2.9285 2.928
Deck Dbottom Mpa -0.792 -0.792 -0.792 -0.718 -0.643 -0.643 -0.643 -0.6427 -0.643
Gtop Mpa -0.792 -0.792 -0.792 -0.718 -0.643 -0.643 -0.643 -0.6427 -0.643
Girder Gbottom Mpa 1.6835 1.6835 1.6835 1.4091 1.1323 1.1323 1.1323 1.1323 1.132
Total Stresses (A+B +C+D+E+F+G+H) (Without SV)
Dtop Mpa 2.5387 2.6254 2.7072 3.6005 4.5637 4.7426 5.9164 6.5085 6.841
Deck Dbottom Mpa -1.005 -0.936 -0.871 -0.187 0.5184 0.6532 1.5378 1.984 2.234
Gtop Mpa 0.0814 0.2012 0.287 2.0287 5.135 5.2779 6.7401 7.7628 8.461
Girder Gbottom Mpa 9.3466 9.1801 9.0506 9.249 10.493 10.174 7.7088 6.307 5.403
Total Stresses (A+B +C+D+E+F+G+H) (With SV Loading)
Dtop Mpa -0.173 -0.113 -0.053 0.5267 1.1689 1.2533 2.2922 3.0062 3.127
Deck Dbottom Mpa -0.213 -0.165 -0.117 0.3332 0.8096 0.8733 1.6562 2.1943 2.286
Gtop Mpa 0.8733 0.9721 1.0409 2.5493 5.4263 5.4979 6.8585 7.9731 8.512
Girder Gbottom Mpa 7.6631 7.5324 7.432 8.2385 10.21 10.063 7.8443 6.2203 5.701

Max Compressive stress = 10.493 Mpa < 24 Mpa OK


Max Tensile Stress = 0.0814 Mpa >= -3.516 Mpa OK

7.2) Rare Combination LC-SR7.2 : At day 92 Structure open to LL - temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.6164 0.4478 0.3 -0.434 -0.394 -0.633 -3.558 -5.1144 -5.369
Girder Gbottom Mpa 7.7954 7.9731 8.1287 11.655 17.224 17.478 20.67 22.488 22.89

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.345
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.9803 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.4912 4.4564 4.77
Girder Gbottom Mpa 0.0017 -0.098 -0.164 -0.88 -1.851 -1.942 -3.505 -4.4747 -4.789

EPC Contractor-M/s Krishna Constructions 142


Design ch-109+720
Design of PSC Girder

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0115 0.0211 0.1118 0.2074 0.2199 0.3759 0.4694 0.5
Deck Dbottom Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.2833 0.3538 0.377
Gtop Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.2833 0.3538 0.377
Girder Gbottom Mpa 0 -0.016 -0.029 -0.175 -0.378 -0.401 -0.685 -0.8554 -0.911
F) Stresses due to Live load (Without SV) Load factor = 1
Dtop Mpa 0 0.0753 0.1474 0.8233 1.5436 1.71 2.7278 3.2263 3.528
Deck Dbottom Mpa 0 0.0598 0.117 0.6387 1.1633 1.2887 2.0557 2.4314 2.659
Gtop Mpa 0 0.0598 0.117 0.6387 1.1633 1.2887 2.0557 2.4314 2.659
Girder Gbottom Mpa 0 -0.102 -0.2 -1.292 -2.813 -3.116 -4.971 -5.8789 -6.429
F.1) Stresses due to Live load (With SV) Load factor = 1
Dtop Mpa 0 0.0489 0.0996 0.5692 1.0773 1.1492 2.0321 2.6525 2.743
Deck Dbottom Mpa 0 0.0388 0.0791 0.4416 0.8118 0.866 1.5314 1.999 2.067
Gtop Mpa 0 0.0388 0.0791 0.4416 0.8118 0.866 1.5314 1.999 2.067
Girder Gbottom Mpa 0 -0.067 -0.135 -0.893 -1.963 -2.094 -3.703 -4.8333 -4.999

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.173 -0.173 -0.173 -0.154 -0.116 -0.116 -0.116 -0.1158 -0.116
Deck Dbottom Mpa -0.213 -0.213 -0.213 -0.195 -0.158 -0.158 -0.158 -0.1585 -0.158
Gtop Mpa 0.2681 0.2681 0.2681 0.2857 0.3223 0.3223 0.3223 0.3223 0.322
Girder Gbottom Mpa -0.144 -0.144 -0.144 -0.141 -0.124 -0.124 -0.124 -0.1242 -0.124
H) -ve temperature stresses Load factor = 0.6
Dtop Mpa -1.699 -1.699 -1.699 -1.643 -1.588 -1.588 -1.588 -1.5877 -1.588
Deck Dbottom Mpa 0.3901 0.3901 0.3901 0.4567 0.524 0.524 0.524 0.524 0.524
Gtop Mpa 0.3901 0.3901 0.3901 0.4567 0.524 0.524 0.524 0.524 0.524
Girder Gbottom Mpa -1.907 -1.907 -1.907 -1.724 -1.538 -1.538 -1.538 -1.5383 -1.538
Total Stresses (A+B +C+D+E+F+G+H) (Without SV)
Dtop Mpa -1.872 -1.785 -1.703 -0.863 0.0475 0.2264 1.4002 1.9923 2.324
Deck Dbottom Mpa 0.1774 0.2463 0.3112 0.987 1.6851 1.8199 2.7045 3.1507 3.401
Gtop Mpa 1.2634 1.3831 1.469 3.2031 6.3017 6.4446 7.9068 8.9295 9.628
Girder Gbottom Mpa 5.7558 5.5893 5.4598 6.1162 7.8221 7.5032 5.0383 3.6364 2.732
Total Stresses (A+B +C+D+E+F+G+H) (With SV Loading)
Dtop Mpa -0.173 -0.113 -0.053 0.5267 1.1689 1.2533 2.2922 3.0062 3.127
Deck Dbottom Mpa -0.213 -0.165 -0.117 0.3332 0.8096 0.8733 1.6562 2.1943 2.286
Gtop Mpa 0.8733 0.9721 1.0409 2.5493 5.4263 5.4979 6.8585 7.9731 8.512
Girder Gbottom Mpa 7.6631 7.5324 7.432 8.2385 10.21 10.063 7.8443 6.2203 5.701

Max Compressive stress = 10.21 Mpa < 24 Mpa OK


Max Tensile Stress = 0.8733 Mpa >= -3.516 Mpa OK

7.3) Rare Combination LC-SR7.3 : At day 92 Structure open to LL + temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.6164 0.4478 0.3 -0.434 -0.394 -0.633 -3.558 -5.1144 -5.369
Girder Gbottom Mpa 7.7954 7.9731 8.1287 11.655 17.224 17.478 20.67 22.488 22.89

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.345
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.9803 -6.371

EPC Contractor-M/s Krishna Constructions 143


Design ch-109+720
Design of PSC Girder

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.4912 4.4564 4.77
Girder Gbottom Mpa 0.0017 -0.098 -0.164 -0.88 -1.851 -1.942 -3.505 -4.4747 -4.789

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0115 0.0211 0.1118 0.2074 0.2199 0.3759 0.4694 0.5
Deck Dbottom Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.2833 0.3538 0.377
Gtop Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.2833 0.3538 0.377
Girder Gbottom Mpa 0 -0.016 -0.029 -0.175 -0.378 -0.401 -0.685 -0.8554 -0.911
F) Stresses due to Live load (Without SV) Load factor = 0.75
Dtop Mpa 0 0.0564 0.1105 0.6175 1.1577 1.2825 2.0459 2.4197 2.646
Deck Dbottom Mpa 0 0.0448 0.0878 0.479 0.8725 0.9665 1.5418 1.8236 1.994
Gtop Mpa 0 0.0448 0.0878 0.479 0.8725 0.9665 1.5418 1.8236 1.994
Girder Gbottom Mpa 0 -0.077 -0.15 -0.969 -2.11 -2.337 -3.728 -4.4092 -4.821
F.1) Stresses due to Live load (With SV) Load factor = 0.75
Dtop Mpa 0 0.0367 0.0747 0.4269 0.8079 0.8619 1.5241 1.9894 2.057
Deck Dbottom Mpa 0 0.0291 0.0593 0.3312 0.6089 0.6495 1.1486 1.4992 1.551
Gtop Mpa 0 0.0291 0.0593 0.3312 0.6089 0.6495 1.1486 1.4992 1.551
Girder Gbottom Mpa 0 -0.05 -0.102 -0.67 -1.472 -1.57 -2.777 -3.625 -3.749

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.173 -0.173 -0.173 -0.154 -0.116 -0.116 -0.116 -0.1158 -0.116
Deck Dbottom Mpa -0.213 -0.213 -0.213 -0.195 -0.158 -0.158 -0.158 -0.1585 -0.158
Gtop Mpa 0.2681 0.2681 0.2681 0.2857 0.3223 0.3223 0.3223 0.3223 0.322
Girder Gbottom Mpa -0.144 -0.144 -0.144 -0.141 -0.124 -0.124 -0.124 -0.1242 -0.124
H) +ve temperature stresses Load factor = 1
Dtop Mpa 4.52 4.52 4.52 4.6996 4.8808 4.8808 4.8808 4.8808 4.881
Deck Dbottom Mpa -1.32 -1.32 -1.32 -1.196 -1.071 -1.071 -1.071 -1.0712 -1.071
Gtop Mpa -1.32 -1.32 -1.32 -1.196 -1.071 -1.071 -1.071 -1.0712 -1.071
Girder Gbottom Mpa 2.8058 2.8058 2.8058 2.3486 1.8872 1.8872 1.8872 1.8872 1.887
Total Stresses (A+B +C+D+E+F+G+H) (Without SV)
Dtop Mpa 4.3466 4.4146 4.4783 5.2745 6.1301 6.2674 7.1868 7.6542 7.911
Deck Dbottom Mpa -1.533 -1.479 -1.428 -0.825 -0.201 -0.097 0.5954 0.9476 1.141
Gtop Mpa -0.446 -0.342 -0.27 1.3907 4.4157 4.5272 5.7976 6.7264 7.368
Girder Gbottom Mpa 10.469 10.328 10.223 10.511 11.951 11.708 9.7063 8.5316 7.765
Total Stresses (A+B +C+D+E+F+G+H) (With SV Loading)
Dtop Mpa -0.173 -0.125 -0.077 0.3844 0.8995 0.966 1.7842 2.343 2.442
Deck Dbottom Mpa -0.213 -0.174 -0.137 0.2228 0.6067 0.6568 1.2734 1.6945 1.769
Gtop Mpa 0.8733 0.9624 1.0212 2.4389 5.2233 5.2814 6.4756 7.4733 7.995
Girder Gbottom Mpa 7.6631 7.5491 7.4659 8.4618 10.701 10.587 8.77 7.4286 6.95

Max Compressive stress = 11.951 Mpa < 24 Mpa OK


Max Tensile Stress = -0.446 Mpa >= -3.516 Mpa OK

7.4) Rare Combination LC-SR7.4 : At day 92 Structure open to LL - temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.6164 0.4478 0.3 -0.434 -0.394 -0.633 -3.558 -5.1144 -5.369
Girder Gbottom Mpa 7.7954 7.9731 8.1287 11.655 17.224 17.478 20.67 22.488 22.89

B) Stresses due to Selfweight of girder Load factor = 1

EPC Contractor-M/s Krishna Constructions 144


Design ch-109+720
Design of PSC Girder

Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.345
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.9803 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.4912 4.4564 4.77
Girder Gbottom Mpa 0.0017 -0.098 -0.164 -0.88 -1.851 -1.942 -3.505 -4.4747 -4.789

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0115 0.0211 0.1118 0.2074 0.2199 0.3759 0.4694 0.5
Deck Dbottom Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.2833 0.3538 0.377
Gtop Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.2833 0.3538 0.377
Girder Gbottom Mpa 0 -0.016 -0.029 -0.175 -0.378 -0.401 -0.685 -0.8554 -0.911
F) Stresses due to Live load (Without SV) Load factor = 0.75
Dtop Mpa 0 0.0564 0.1105 0.6175 1.1577 1.2825 2.0459 2.4197 2.646
Deck Dbottom Mpa 0 0.0448 0.0878 0.479 0.8725 0.9665 1.5418 1.8236 1.994
Gtop Mpa 0 0.0448 0.0878 0.479 0.8725 0.9665 1.5418 1.8236 1.994
Girder Gbottom Mpa 0 -0.077 -0.15 -0.969 -2.11 -2.337 -3.728 -4.4092 -4.821
F.1) Stresses due to Live load (With SV) Load factor = 0.75
Dtop Mpa 0 0.0367 0.0747 0.4269 0.8079 0.8619 1.5241 1.9894 2.057
Deck Dbottom Mpa 0 0.0291 0.0593 0.3312 0.6089 0.6495 1.1486 1.4992 1.551
Gtop Mpa 0 0.0291 0.0593 0.3312 0.6089 0.6495 1.1486 1.4992 1.551
Girder Gbottom Mpa 0 -0.05 -0.102 -0.67 -1.472 -1.57 -2.777 -3.625 -3.749

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.173 -0.173 -0.173 -0.154 -0.116 -0.116 -0.116 -0.1158 -0.116
Deck Dbottom Mpa -0.213 -0.213 -0.213 -0.195 -0.158 -0.158 -0.158 -0.1585 -0.158
Gtop Mpa 0.2681 0.2681 0.2681 0.2857 0.3223 0.3223 0.3223 0.3223 0.322
Girder Gbottom Mpa -0.144 -0.144 -0.144 -0.141 -0.124 -0.124 -0.124 -0.1242 -0.124
H) -ve temperature stresses Load factor = 1
Dtop Mpa -2.831 -2.831 -2.831 -2.739 -2.646 -2.646 -2.646 -2.6462 -2.646
Deck Dbottom Mpa 0.6502 0.6502 0.6502 0.7612 0.8733 0.8733 0.8733 0.8733 0.873
Gtop Mpa 0.6502 0.6502 0.6502 0.7612 0.8733 0.8733 0.8733 0.8733 0.873
Girder Gbottom Mpa -3.179 -3.179 -3.179 -2.873 -2.564 -2.564 -2.564 -2.5638 -2.564
Total Stresses (A+B +C+D+E+F+G+H) (Without SV)
Dtop Mpa -3.004 -2.936 -2.873 -2.164 -1.397 -1.26 -0.34 0.1272 0.384
Deck Dbottom Mpa 0.4375 0.4914 0.542 1.1318 1.7436 1.847 2.5399 2.8921 3.086
Gtop Mpa 1.5235 1.6283 1.6998 3.3479 6.3602 6.4717 7.7422 8.6709 9.312
Girder Gbottom Mpa 4.4843 4.3434 4.2384 5.2901 7.4998 7.2567 5.2554 4.0807 3.314
Total Stresses (A+B +C+D+E+F+G+H) (With SV Loading)
Dtop Mpa -0.173 -0.125 -0.077 0.3844 0.8995 0.966 1.7842 2.343 2.442
Deck Dbottom Mpa -0.213 -0.174 -0.137 0.2228 0.6067 0.6568 1.2734 1.6945 1.769
Gtop Mpa 0.8733 0.9624 1.0212 2.4389 5.2233 5.2814 6.4756 7.4733 7.995
Girder Gbottom Mpa 7.6631 7.5491 7.4659 8.4618 10.701 10.587 8.77 7.4286 6.95

Max Compressive stress = 10.701 Mpa < 24 Mpa OK


Max Tensile Stress = 0.8733 Mpa >= -3.516 Mpa OK

8) Rare Combination LC-SR8 : At day 36500


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.6515 0.5002 0.3677 -0.25 -0.148 -0.357 -2.927 -4.2979 -4.517
Girder

EPC Contractor-M/s Krishna Constructions 145


Design ch-109+720
Design of PSC Girder

Girder Gbottom Mpa 6.8121 6.9712 7.11 10.101 14.632 14.852 17.651 19.239 19.58

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.345
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.9803 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.4912 4.4564 4.77
Girder Gbottom Mpa 0.0017 -0.098 -0.164 -0.88 -1.851 -1.942 -3.505 -4.4747 -4.789

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.1) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.2) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0115 0.0211 0.1118 0.2074 0.2199 0.3759 0.4694 0.5
Deck Dbottom Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.2833 0.3538 0.377
Gtop Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.2833 0.3538 0.377
Girder Gbottom Mpa 0 -0.016 -0.029 -0.175 -0.378 -0.401 -0.685 -0.8554 -0.911
F) Stresses due to Live load (Without SV) Load factor = 1
Dtop Mpa 0 0.0753 0.1474 0.8233 1.5436 1.71 2.7278 3.2263 3.528
Deck Dbottom Mpa 0 0.0598 0.117 0.6387 1.1633 1.2887 2.0557 2.4314 2.659
Gtop Mpa 0 0.0598 0.117 0.6387 1.1633 1.2887 2.0557 2.4314 2.659
Girder Gbottom Mpa 0 -0.102 -0.2 -1.292 -2.813 -3.116 -4.971 -5.8789 -6.429
F.1) Stresses due to Live load (With SV) Load factor = 1
Dtop Mpa 0 0.0489 0.0996 0.5692 1.0773 1.1492 2.0321 2.6525 2.743
Deck Dbottom Mpa 0 0.0388 0.0791 0.4416 0.8118 0.866 1.5314 1.999 2.067
Gtop Mpa 0 0.0388 0.0791 0.4416 0.8118 0.866 1.5314 1.999 2.067
Girder Gbottom Mpa 0 -0.067 -0.135 -0.893 -1.963 -2.094 -3.703 -4.8333 -4.999

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.713 -0.713 -0.713 -0.635 -0.477 -0.477 -0.477 -0.4765 -0.477
Deck Dbottom Mpa -0.875 -0.875 -0.875 -0.803 -0.652 -0.652 -0.652 -0.6523 -0.652
Gtop Mpa 1.1035 1.1035 1.1035 1.1759 1.3266 1.3266 1.3266 1.3266 1.327
Girder Gbottom Mpa -0.592 -0.592 -0.592 -0.58 -0.511 -0.511 -0.511 -0.511 -0.511
Total Stresses (A+B +C+D+E+F+G+H) (Without SV)
Dtop Mpa -0.713 -0.627 -0.545 0.3001 1.2745 1.4533 2.6272 3.2192 3.551
Deck Dbottom Mpa -0.875 -0.807 -0.742 -0.078 0.6673 0.8021 1.6867 2.1329 2.383
Gtop Mpa 1.7438 1.8807 1.9819 3.8205 7.0285 7.2011 9.0184 10.226 10.96
Girder Gbottom Mpa 6.2317 6.0467 5.9003 5.8466 6.3816 6.0287 3.1709 1.5387 0.569
Total Stresses (A+B +C+D+E+F+G+H) (With SV Loading)
Dtop Mpa 0 0.0604 0.1207 0.681 1.2846 1.3691 2.408 3.1219 3.243
Deck Dbottom Mpa 0 0.048 0.0959 0.5283 0.9681 1.0318 1.8147 2.3528 2.444
Gtop Mpa 0.6404 0.7564 0.8406 2.4475 5.3504 5.4518 7.1675 8.4672 9.042
Girder Gbottom Mpa 6.8236 6.6743 6.5571 6.8255 7.7424 7.5616 4.9496 3.0953 2.51

Max Compressive stress = 10.96 Mpa < 24 Mpa OK


Max Tensile Stress = 0.5692 Mpa >= -3.516 Mpa OK

8.1) Rare Combination LC-SR8.1 : At day 36500 + temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.6515 0.5002 0.3677 -0.25 -0.148 -0.357 -2.927 -4.2979 -4.517
Girder Gbottom Mpa 6.8121 6.9712 7.11 10.101 14.632 14.852 17.651 19.239 19.58

EPC Contractor-M/s Krishna Constructions 146


Design ch-109+720
Design of PSC Girder

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.345
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.9803 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.4912 4.4564 4.77
Girder Gbottom Mpa 0.0017 -0.098 -0.164 -0.88 -1.851 -1.942 -3.505 -4.4747 -4.789

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.1) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.2) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0115 0.0211 0.1118 0.2074 0.2199 0.3759 0.4694 0.5
Deck Dbottom Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.2833 0.3538 0.377
Gtop Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.2833 0.3538 0.377
Girder Gbottom Mpa 0 -0.016 -0.029 -0.175 -0.378 -0.401 -0.685 -0.8554 -0.911
F) Stresses due to Live load (Without SV) Load factor = 1
Dtop Mpa 0 0.0753 0.1474 0.8233 1.5436 1.71 2.7278 3.2263 3.528
Deck Dbottom Mpa 0 0.0598 0.117 0.6387 1.1633 1.2887 2.0557 2.4314 2.659
Gtop Mpa 0 0.0598 0.117 0.6387 1.1633 1.2887 2.0557 2.4314 2.659
Girder Gbottom Mpa 0 -0.102 -0.2 -1.292 -2.813 -3.116 -4.971 -5.8789 -6.429
F.1) Stresses due to Live load (With SV) Load factor = 1
Dtop Mpa 0 0.0489 0.0996 0.5692 1.0773 1.1492 2.0321 2.6525 2.743
Deck Dbottom Mpa 0 0.0388 0.0791 0.4416 0.8118 0.866 1.5314 1.999 2.067
Gtop Mpa 0 0.0388 0.0791 0.4416 0.8118 0.866 1.5314 1.999 2.067
Girder Gbottom Mpa 0 -0.067 -0.135 -0.893 -1.963 -2.094 -3.703 -4.8333 -4.999

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.713 -0.713 -0.713 -0.635 -0.477 -0.477 -0.477 -0.4765 -0.477
Deck Dbottom Mpa -0.875 -0.875 -0.875 -0.803 -0.652 -0.652 -0.652 -0.6523 -0.652
Gtop Mpa 1.1035 1.1035 1.1035 1.1759 1.3266 1.3266 1.3266 1.3266 1.327
Girder Gbottom Mpa -0.592 -0.592 -0.592 -0.58 -0.511 -0.511 -0.511 -0.511 -0.511

H) +ve temperature stresses Load factor = 0.6


Dtop Mpa 2.712 2.712 2.712 2.8197 2.9285 2.9285 2.9285 2.9285 2.928
Deck Dbottom Mpa -0.792 -0.792 -0.792 -0.718 -0.643 -0.643 -0.643 -0.6427 -0.643
Gtop Mpa -0.792 -0.792 -0.792 -0.718 -0.643 -0.643 -0.643 -0.6427 -0.643
Girder Gbottom Mpa 1.6835 1.6835 1.6835 1.4091 1.1323 1.1323 1.1323 1.1323 1.132
Total Stresses (A+B +C+D+E+F+G+H) (Without SV)
Dtop Mpa 1.9987 2.0854 2.1672 3.1198 4.2029 4.3818 5.5557 6.1477 6.48
Deck Dbottom Mpa -1.667 -1.598 -1.534 -0.795 0.0245 0.1594 1.044 1.4902 1.74
Gtop Mpa 0.9519 1.0889 1.1901 3.1029 6.3858 6.5583 8.3757 9.5835 10.32
Girder Gbottom Mpa 7.9152 7.7301 7.5837 7.2557 7.5139 7.161 4.3032 2.671 1.701
Total Stresses (A+B +C+D+E+F+G+H) (With SV Loading)
Dtop Mpa -0.713 -0.653 -0.593 0.046 0.8081 0.8925 1.9315 2.6454 2.767
Deck Dbottom Mpa -0.875 -0.828 -0.78 -0.275 0.3158 0.3794 1.1624 1.7004 1.792
Gtop Mpa 1.7438 1.8598 1.944 3.6234 6.677 6.7784 8.4941 9.7938 10.37
Girder Gbottom Mpa 6.2317 6.0825 5.9652 6.2453 7.2314 7.0506 4.4386 2.5843 1.999

Max Compressive stress = 10.368 Mpa < 24 Mpa OK


Max Tensile Stress = 0.9519 Mpa >= -3.516 Mpa OK

8.2) Rare Combination LC-SR8.2 : At day 36500 - temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1

EPC Contractor-M/s Krishna Constructions 147


Design ch-109+720
Design of PSC Girder

A) Stresses due to Prestress force Load factor = 1


Gtop Mpa 0.6515 0.5002 0.3677 -0.25 -0.148 -0.357 -2.927 -4.2979 -4.517
Girder Gbottom Mpa 6.8121 6.9712 7.11 10.101 14.632 14.852 17.651 19.239 19.58

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.345
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.9803 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.4912 4.4564 4.77
Girder Gbottom Mpa 0.0017 -0.098 -0.164 -0.88 -1.851 -1.942 -3.505 -4.4747 -4.789

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.1) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.2) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0115 0.0211 0.1118 0.2074 0.2199 0.3759 0.4694 0.5
Deck Dbottom Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.2833 0.3538 0.377
Gtop Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.2833 0.3538 0.377
Girder Gbottom Mpa 0 -0.016 -0.029 -0.175 -0.378 -0.401 -0.685 -0.8554 -0.911
F) Stresses due to Live load (Without SV) Load factor = 1
Dtop Mpa 0 0.0753 0.1474 0.8233 1.5436 1.71 2.7278 3.2263 3.528
Deck Dbottom Mpa 0 0.0598 0.117 0.6387 1.1633 1.2887 2.0557 2.4314 2.659
Gtop Mpa 0 0.0598 0.117 0.6387 1.1633 1.2887 2.0557 2.4314 2.659
Girder Gbottom Mpa 0 -0.102 -0.2 -1.292 -2.813 -3.116 -4.971 -5.8789 -6.429
F.1) Stresses due to Live load (With SV) Load factor = 1
Dtop Mpa 0 0.0489 0.0996 0.5692 1.0773 1.1492 2.0321 2.6525 2.743
Deck Dbottom Mpa 0 0.0388 0.0791 0.4416 0.8118 0.866 1.5314 1.999 2.067
Gtop Mpa 0 0.0388 0.0791 0.4416 0.8118 0.866 1.5314 1.999 2.067
Girder Gbottom Mpa 0 -0.067 -0.135 -0.893 -1.963 -2.094 -3.703 -4.8333 -4.999

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.713 -0.713 -0.713 -0.635 -0.477 -0.477 -0.477 -0.4765 -0.477
Deck Dbottom Mpa -0.875 -0.875 -0.875 -0.803 -0.652 -0.652 -0.652 -0.6523 -0.652
Gtop Mpa 1.1035 1.1035 1.1035 1.1759 1.3266 1.3266 1.3266 1.3266 1.327
Girder Gbottom Mpa -0.592 -0.592 -0.592 -0.58 -0.511 -0.511 -0.511 -0.511 -0.511

H) -ve temperature stresses Load factor = 0.6


Dtop Mpa -1.699 -1.699 -1.699 -1.643 -1.588 -1.588 -1.588 -1.5877 -1.588
Deck Dbottom Mpa 0.3901 0.3901 0.3901 0.4567 0.524 0.524 0.524 0.524 0.524
Gtop Mpa 0.3901 0.3901 0.3901 0.4567 0.524 0.524 0.524 0.524 0.524
Girder Gbottom Mpa -1.907 -1.907 -1.907 -1.724 -1.538 -1.538 -1.538 -1.5383 -1.538
Total Stresses (A+B +C+D+E+F+G+H) (Without SV)
Dtop Mpa -2.412 -2.325 -2.243 -1.343 -0.313 -0.134 1.0395 1.6315 1.964
Deck Dbottom Mpa -0.485 -0.416 -0.352 0.3791 1.1913 1.3261 2.2107 2.6569 2.907
Gtop Mpa 2.1339 2.2708 2.372 4.2773 7.5525 7.725 9.5424 10.75 11.48
Girder Gbottom Mpa 4.3244 4.1394 3.993 4.1229 4.8434 4.4904 1.6326 0.0004 -0.969
Total Stresses (A+B +C+D+E+F+G+H) (With SV Loading)
Dtop Mpa -0.713 -0.653 -0.593 0.046 0.8081 0.8925 1.9315 2.6454 2.767
Deck Dbottom Mpa -0.875 -0.828 -0.78 -0.275 0.3158 0.3794 1.1624 1.7004 1.792
Gtop Mpa 1.7438 1.8598 1.944 3.6234 6.677 6.7784 8.4941 9.7938 10.37
Girder Gbottom Mpa 6.2317 6.0825 5.9652 6.2453 7.2314 7.0506 4.4386 2.5843 1.999

Max Compressive stress = 11.484 Mpa < 24 Mpa OK


Max Tensile Stress = -0.969 Mpa >= -3.516 Mpa OK

EPC Contractor-M/s Krishna Constructions 148


Design ch-109+720
Design of PSC Girder

8.3) Rare Combination LC-SR8.3 : At day 36500 + temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.6515 0.5002 0.3677 -0.25 -0.148 -0.357 -2.927 -4.2979 -4.517
Girder Gbottom Mpa 6.8121 6.9712 7.11 10.101 14.632 14.852 17.651 19.239 19.58

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.345
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.9803 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.4912 4.4564 4.77
Girder Gbottom Mpa 0.0017 -0.098 -0.164 -0.88 -1.851 -1.942 -3.505 -4.4747 -4.789

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.1) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.2) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0115 0.0211 0.1118 0.2074 0.2199 0.3759 0.4694 0.5
Deck Dbottom Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.2833 0.3538 0.377
Gtop Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.2833 0.3538 0.377
Girder Gbottom Mpa 0 -0.016 -0.029 -0.175 -0.378 -0.401 -0.685 -0.8554 -0.911
F) Stresses due to Live load (Without SV) Load factor = 0.75
Dtop Mpa 0 0.0564 0.1105 0.6175 1.1577 1.2825 2.0459 2.4197 2.646
Deck Dbottom Mpa 0 0.0448 0.0878 0.479 0.8725 0.9665 1.5418 1.8236 1.994
Gtop Mpa 0 0.0448 0.0878 0.479 0.8725 0.9665 1.5418 1.8236 1.994
Girder Gbottom Mpa 0 -0.077 -0.15 -0.969 -2.11 -2.337 -3.728 -4.4092 -4.821
F.1) Stresses due to Live load (With SV) Load factor = 0.75
Dtop Mpa 0 0.0367 0.0747 0.4269 0.8079 0.8619 1.5241 1.9894 2.057
Deck Dbottom Mpa 0 0.0291 0.0593 0.3312 0.6089 0.6495 1.1486 1.4992 1.551
Gtop Mpa 0 0.0291 0.0593 0.3312 0.6089 0.6495 1.1486 1.4992 1.551
Girder Gbottom Mpa 0 -0.05 -0.102 -0.67 -1.472 -1.57 -2.777 -3.625 -3.749

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.713 -0.713 -0.713 -0.635 -0.477 -0.477 -0.477 -0.4765 -0.477
Deck Dbottom Mpa -0.875 -0.875 -0.875 -0.803 -0.652 -0.652 -0.652 -0.6523 -0.652
Gtop Mpa 1.1035 1.1035 1.1035 1.1759 1.3266 1.3266 1.3266 1.3266 1.327
Girder Gbottom Mpa -0.592 -0.592 -0.592 -0.58 -0.511 -0.511 -0.511 -0.511 -0.511

H) +ve temperature stresses Load factor = 1


Dtop Mpa 4.52 4.52 4.52 4.6996 4.8808 4.8808 4.8808 4.8808 4.881
Deck Dbottom Mpa -1.32 -1.32 -1.32 -1.196 -1.071 -1.071 -1.071 -1.0712 -1.071
Gtop Mpa -1.32 -1.32 -1.32 -1.196 -1.071 -1.071 -1.071 -1.0712 -1.071
Girder Gbottom Mpa 2.8058 2.8058 2.8058 2.3486 1.8872 1.8872 1.8872 1.8872 1.887
Total Stresses (A+B +C+D+E+F+G+H) (Without SV)
Dtop Mpa 3.8067 3.8746 3.9383 4.7938 5.7694 5.9066 6.826 7.2934 7.55
Deck Dbottom Mpa -2.195 -2.141 -2.091 -1.433 -0.695 -0.591 0.1016 0.4538 0.647
Gtop Mpa 0.424 0.546 0.6329 2.4648 5.6664 5.8077 7.4332 8.5472 9.224
Girder Gbottom Mpa 9.0375 8.878 8.7561 8.5181 8.972 8.6948 6.3007 4.8955 4.064
Total Stresses (A+B +C+D+E+F+G+H) (With SV Loading)
Dtop Mpa -0.713 -0.665 -0.617 -0.096 0.5388 0.6052 1.4234 1.9823 2.081
Deck Dbottom Mpa -0.875 -0.837 -0.799 -0.385 0.1129 0.1629 0.7796 1.2007 1.275
Gtop Mpa 1.7438 1.8501 1.9242 3.5131 6.4741 6.5619 8.1112 9.2941 9.851
Girder Gbottom Mpa 6.2317 6.0991 5.9991 6.4686 7.7221 7.574 5.3643 3.7926 3.249

Max Compressive stress = 9.8513 Mpa < 24 Mpa OK


Max Tensile Stress = 0.424 Mpa >= -3.516 Mpa OK

EPC Contractor-M/s Krishna Constructions 149


Design ch-109+720
Design of PSC Girder

8.4) Rare Combination LC-SR8.4 : At day 36500 - temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.6515 0.5002 0.3677 -0.25 -0.148 -0.357 -2.927 -4.2979 -4.517
Girder Gbottom Mpa 6.8121 6.9712 7.11 10.101 14.632 14.852 17.651 19.239 19.58

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.345
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.9803 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.4912 4.4564 4.77
Girder Gbottom Mpa 0.0017 -0.098 -0.164 -0.88 -1.851 -1.942 -3.505 -4.4747 -4.789

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.1) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.2) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0115 0.0211 0.1118 0.2074 0.2199 0.3759 0.4694 0.5
Deck Dbottom Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.2833 0.3538 0.377
Gtop Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.2833 0.3538 0.377
Girder Gbottom Mpa 0 -0.016 -0.029 -0.175 -0.378 -0.401 -0.685 -0.8554 -0.911
F) Stresses due to Live load (Without SV) Load factor = 0.75
Dtop Mpa 0 0.0564 0.1105 0.6175 1.1577 1.2825 2.0459 2.4197 2.646
Deck Dbottom Mpa 0 0.0448 0.0878 0.479 0.8725 0.9665 1.5418 1.8236 1.994
Gtop Mpa 0 0.0448 0.0878 0.479 0.8725 0.9665 1.5418 1.8236 1.994
Girder Gbottom Mpa 0 -0.077 -0.15 -0.969 -2.11 -2.337 -3.728 -4.4092 -4.821
F.1) Stresses due to Live load (With SV) Load factor = 0.75
Dtop Mpa 0 0.0367 0.0747 0.4269 0.8079 0.8619 1.5241 1.9894 2.057
Deck Dbottom Mpa 0 0.0291 0.0593 0.3312 0.6089 0.6495 1.1486 1.4992 1.551
Gtop Mpa 0 0.0291 0.0593 0.3312 0.6089 0.6495 1.1486 1.4992 1.551
Girder Gbottom Mpa 0 -0.05 -0.102 -0.67 -1.472 -1.57 -2.777 -3.625 -3.749

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.713 -0.713 -0.713 -0.635 -0.477 -0.477 -0.477 -0.4765 -0.477
Deck Dbottom Mpa -0.875 -0.875 -0.875 -0.803 -0.652 -0.652 -0.652 -0.6523 -0.652
Gtop Mpa 1.1035 1.1035 1.1035 1.1759 1.3266 1.3266 1.3266 1.3266 1.327
Girder Gbottom Mpa -0.592 -0.592 -0.592 -0.58 -0.511 -0.511 -0.511 -0.511 -0.511

H) -ve temperature stresses Load factor = 1


Dtop Mpa -2.831 -2.831 -2.831 -2.739 -2.646 -2.646 -2.646 -2.6462 -2.646
Deck Dbottom Mpa 0.6502 0.6502 0.6502 0.7612 0.8733 0.8733 0.8733 0.8733 0.873
Gtop Mpa 0.6502 0.6502 0.6502 0.7612 0.8733 0.8733 0.8733 0.8733 0.873
Girder Gbottom Mpa -3.179 -3.179 -3.179 -2.873 -2.564 -2.564 -2.564 -2.5638 -2.564
Total Stresses (A+B +C+D+E+F+G+H)
Dtop Mpa -3.544 -3.476 -3.413 -2.645 -1.758 -1.62 -0.701 -0.2335 0.023
Deck Dbottom Mpa -0.225 -0.171 -0.121 0.5239 1.2497 1.3532 2.0461 2.3983 2.592
Gtop Mpa 2.394 2.516 2.6029 4.4221 7.611 7.7522 9.3777 10.492 11.17
Girder Gbottom Mpa 3.0529 2.8934 2.7715 3.2968 4.521 4.2438 1.8497 0.4446 -0.387
Total Stresses (A+B +C+D+E+F+G+H)
Dtop Mpa -0.713 -0.665 -0.617 -0.096 0.5388 0.6052 1.4234 1.9823 2.081
Deck Dbottom Mpa -0.875 -0.837 -0.799 -0.385 0.1129 0.1629 0.7796 1.2007 1.275
Gtop Mpa 1.7438 1.8501 1.9242 3.5131 6.4741 6.5619 8.1112 9.2941 9.851
Girder Gbottom Mpa 6.2317 6.0991 5.9991 6.4686 7.7221 7.574 5.3643 3.7926 3.249

EPC Contractor-M/s Krishna Constructions 150


Design ch-109+720
Design of PSC Girder

Max Compressive stress = 11.168 Mpa < 24 Mpa OK


Max Tensile Stress = -0.387 Mpa >= -3.516 Mpa OK

SUMMARY FOR SLS RARE COMBINATION


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
1) Rare Combination LC-SR1 : At the time of 1st stage prestress, just after ES loss of Stage -I cables
Total Stresses (A+B)
Gtop Mpa -2.663 -2.593 -2.535 -1.956 -0.653 -0.574 0.4343 1.0932 1.373
Girder Gbottom Mpa 8.4143 8.3453 8.2871 9.5813 12.2 12.129 11.247 10.717 10.55
2) Rare Combination LC-SR2 At day 28 Just before II Stage prestressing
Total Stresses (A+B)
Gtop Mpa -2.549 -2.477 -2.416 -1.8 -0.464 -0.38 0.6822 1.3707 1.659
Girder Gbottom Mpa 8.0535 7.9819 7.9214 9.0586 11.354 11.278 10.333 9.764 9.577
3) Rare Combination LC-SR3 : At day 28 Just after II Stage prestressing after ES
Total Stresses (A+B)
Gtop Mpa 0.6544 0.601 0.5517 0.8605 2.2543 2.1579 1.0205 0.555 0.681
Girder Gbottom Mpa 8.073 8.1323 8.1868 10.817 15.444 15.558 16.965 17.697 17.72
4) Rare Combination LC-SR4 : At day 35 At the time of casting of deck slab
Total Stresses (A+B)
Gtop Mpa 0.6014 0.649 0.6668 1.7002 4.0839 4.0854 4.5972 5.1531 5.602
Girder Gbottom Mpa 8.0083 7.9626 7.9472 9.7702 13.231 13.242 12.93 12.587 12.27
5) Rare Combination LC-SR5 : At day 63 At the time of transfer over permanent bearings
Total Stresses (A+B)
Gtop Mpa 0.8841 0.9337 0.9535 2.0208 4.4529 4.4587 5.0125 5.5807 6.029
Girder Gbottom Mpa 7.7297 7.6822 7.665 9.4182 12.749 12.757 12.442 12.116 11.81
6) Rare Combination LC-SR6 : At day 64 At the time of placing of SIDL
Total Stresses (A+B)
Gtop Mpa 0.8839 0.9427 0.9702 2.1079 4.6099 4.6252 5.2979 5.9371 6.408
Girder Gbottom Mpa 7.7268 7.6636 7.6331 9.2377 12.362 12.348 11.746 11.25 10.89
7) Rare Combination LC-SR7 : At day 92 Structure open to LL
Total Stresses (A+B)
Gtop Mpa 0.8733 0.993 1.0788 2.7464 5.7777 5.9206 7.3828 8.4055 9.104
Girder Gbottom Mpa 7.6631 7.4966 7.3671 7.8398 9.3604 9.0415 6.5766 5.1747 4.271
7.1) Rare Combination LC-SR7.1 : At day 92 Structure open to LL + temperature stresses
Total Stresses (A+B)
Gtop Mpa 0.0814 0.2012 0.287 2.0287 5.135 5.2779 6.7401 7.7628 8.461
Girder Gbottom Mpa 9.3466 9.1801 9.0506 9.249 10.493 10.174 7.7088 6.307 5.403
7.2) Rare Combination LC-SR7.2: At day 92 Structure open to LL - temperature stresses
Total Stresses (A+B)
Gtop Mpa 1.2634 1.3831 1.469 3.2031 6.3017 6.4446 7.9068 8.9295 9.628
Girder Gbottom Mpa 5.7558 5.5893 5.4598 6.1162 7.8221 7.5032 5.0383 3.6364 2.732
7.3) Rare Combination LC-SR7.3 : At day 92 Structure open to LL + temperature stresses
Total Stresses (A+B)
Gtop Mpa -0.446 -0.342 -0.27 1.3907 4.4157 4.5272 5.7976 6.7264 7.368
Girder Gbottom Mpa 10.469 10.328 10.223 10.511 11.951 11.708 9.7063 8.5316 7.765
7.4) Rare Combination LC-SR7.4 : At day 92 Structure open to LL - temperature stresses
Total Stresses (A+B)
Gtop Mpa 1.5235 1.6283 1.6998 3.3479 6.3602 6.4717 7.7422 8.6709 9.312
Girder Gbottom Mpa 4.4843 4.3434 4.2384 5.2901 7.4998 7.2567 5.2554 4.0807 3.314

Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
8) Rare Combination LC-SR8 : At day 36500
Total Stresses (A+B)
Gtop Mpa 1.7438 1.8807 1.9819 3.8205 7.0285 7.2011 9.0184 10.226 10.96
Girder Gbottom Mpa 6.2317 6.0467 5.9003 5.8466 6.3816 6.0287 3.1709 1.5387 0.569
8.1) Rare Combination LC-SR8.1 : At day 36500 + temperature stresses
Total Stresses (A+B)
Gtop Mpa 0.9519 1.0889 1.1901 3.1029 6.3858 6.5583 8.3757 9.5835 10.32
Girder Gbottom Mpa 7.9152 7.7301 7.5837 7.2557 7.5139 7.161 4.3032 2.671 1.701
8.2) Rare Combination LC-SR8.2 : At day 36500 - temperature stresses
Total Stresses (A+B)

EPC Contractor-M/s Krishna Constructions 151


Design ch-109+720
Design of PSC Girder

Gtop Mpa 2.1339 2.2708 2.372 4.2773 7.5525 7.725 9.5424 10.75 11.48
Girder Gbottom Mpa 4.3244 4.1394 3.993 4.1229 4.8434 4.4904 1.6326 0.0004 -0.969
8.3) Rare Combination LC-SR8.3 : At day 36500 + temperature stresses
Total Stresses (A+B)
Gtop Mpa 0.424 0.546 0.6329 2.4648 5.6664 5.8077 7.4332 8.5472 9.224
Girder Gbottom Mpa 9.0375 8.878 8.7561 8.5181 8.972 8.6948 6.3007 4.8955 4.064
8.4) Rare Combination LC-SR8.4 : At day 36500 - temperature stresses
Total Stresses (A+B)
Gtop Mpa 2.394 2.516 2.6029 4.4221 7.611 7.7522 9.3777 10.492 11.17
Girder Gbottom Mpa 3.0529 2.8934 2.7715 3.2968 4.521 4.2438 1.8497 0.4446 -0.387

FREQUENT LOAD COMBINATIONS :


1) Frequent Combination LC-SF1 : At day 92 Structure open to LL
Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.6164 0.4478 0.3 -0.434 -0.394 -0.633 -3.558 -5.1144 -5.369
Girder Gbottom Mpa 7.7954 7.9731 8.1287 11.655 17.224 17.478 20.67 22.488 22.89

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.345
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.9803 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.4912 4.4564 4.77
Girder Gbottom Mpa 0.0017 -0.098 -0.164 -0.88 -1.851 -1.942 -3.505 -4.4747 -4.789

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0115 0.0211 0.1118 0.2074 0.2199 0.3759 0.4694 0.5
Deck Dbottom Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.2833 0.3538 0.377
Gtop Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.2833 0.3538 0.377
Girder Gbottom Mpa 0 -0.016 -0.029 -0.175 -0.378 -0.401 -0.685 -0.8554 -0.911
F) Stresses due to Live load (Without SV) Load factor = 0.75
Dtop Mpa 0 0.0564 0.1105 0.6175 1.1577 1.2825 2.0459 2.4197 2.646
Deck Dbottom Mpa 0 0.0448 0.0878 0.479 0.8725 0.9665 1.5418 1.8236 1.994
Gtop Mpa 0 0.0448 0.0878 0.479 0.8725 0.9665 1.5418 1.8236 1.994
Girder Gbottom Mpa 0 -0.077 -0.15 -0.969 -2.11 -2.337 -3.728 -4.4092 -4.821
F.1) Stresses due to Live load (With SV) Load factor = 0.75
Dtop Mpa 0 0.0367 0.0747 0.4269 0.8079 0.8619 1.5241 1.9894 2.057
Deck Dbottom Mpa 0 0.0291 0.0593 0.3312 0.6089 0.6495 1.1486 1.4992 1.551
Gtop Mpa 0 0.0291 0.0593 0.3312 0.6089 0.6495 1.1486 1.4992 1.551
Girder Gbottom Mpa 0 -0.05 -0.102 -0.67 -1.472 -1.57 -2.777 -3.625 -3.749

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.173 -0.173 -0.173 -0.154 -0.116 -0.116 -0.116 -0.1158 -0.116
Deck Dbottom Mpa -0.213 -0.213 -0.213 -0.195 -0.158 -0.158 -0.158 -0.1585 -0.158
Gtop Mpa 0.2681 0.2681 0.2681 0.2857 0.3223 0.3223 0.3223 0.3223 0.322
Girder Gbottom Mpa -0.144 -0.144 -0.144 -0.141 -0.124 -0.124 -0.124 -0.1242 -0.124
G) Stresses due to wind Load factor = 0.5
Dtop Mpa 0 0.0056 0.0104 0.055 0.1021 0.1083 0.1851 0.2311 0.246
Deck Dbottom Mpa 0 0.0045 0.0083 0.0427 0.0769 0.0816 0.1395 0.1742 0.185
Gtop Mpa 0 0.0045 0.0083 0.0427 0.0769 0.0816 0.1395 0.1742 0.185
Girder Gbottom Mpa 0 -0.008 -0.014 -0.086 -0.186 -0.197 -0.337 -0.4211 -0.448
Total Stresses (A+B +C+D+E+F+G) (Without SV Loading)

EPC Contractor-M/s Krishna Constructions 152


Design ch-109+720
Design of PSC Girder

Dtop Mpa -0.173 -0.105 -0.042 0.575 1.2493 1.3866 2.306 2.7734 3.03
Deck Dbottom Mpa -0.213 -0.159 -0.108 0.3706 0.8703 0.9737 1.6666 2.0189 2.212
Gtop Mpa 0.8733 0.9781 1.0496 2.5867 5.4869 5.5984 6.8689 7.7977 8.439
Girder Gbottom Mpa 7.6631 7.5222 7.4172 8.1628 10.064 9.8204 7.8192 6.6444 5.878
Total Stresses (A+B +C+D+E+F+G) (With SV Loading)
Dtop Mpa -0.173 -0.125 -0.077 0.3844 0.8995 0.966 1.7842 2.343 2.442
Deck Dbottom Mpa -0.213 -0.174 -0.137 0.2228 0.6067 0.6568 1.2734 1.6945 1.769
Gtop Mpa 0.8733 0.9624 1.0212 2.4389 5.2233 5.2814 6.4756 7.4733 7.995
Girder Gbottom Mpa 7.6631 7.5491 7.4659 8.4618 10.701 10.587 8.77 7.4286 6.95
Total Stresses (A+B +C+D+E+F+G) wind downward
Dtop Mpa -0.173 -0.1 -0.031 0.63 1.3514 1.4949 2.491 3.0045 3.276
Deck Dbottom Mpa -0.213 -0.154 -0.1 0.4133 0.9472 1.0553 1.8061 2.193 2.398
Gtop Mpa 0.8733 0.9826 1.0579 2.6294 5.5638 5.68 7.0083 7.9718 8.624
Girder Gbottom Mpa 7.6631 7.5145 7.4031 8.0765 9.8775 9.6232 7.482 6.2233 5.429
Total Stresses (A+B +C+D+E+F+G) wind upward
Dtop Mpa -0.173 -0.111 -0.052 0.52 1.1472 1.2783 2.1209 2.5423 2.784
Deck Dbottom Mpa -0.213 -0.163 -0.116 0.3279 0.7933 0.8921 1.5271 1.8447 2.027
Gtop Mpa 0.8733 0.9736 1.0413 2.544 5.41 5.5168 6.7294 7.6235 8.254
Girder Gbottom Mpa 7.6631 7.5299 7.4314 8.2491 10.25 10.018 8.1564 7.0655 6.326

Max Compressive stress = 10.701 Mpa < 24 Mpa OK


Max Tensile Stress = 0.8733 Mpa >= -3.516 Mpa OK

Max Compressive stress (wind downward) = 9.8775 Mpa < 24 Mpa OK


Max Tensile Stress (wind downward) = 0.8733 Mpa >= -3.516 Mpa OK

Max Compressive stress (wind upward) = 10.25 Mpa < 24 Mpa OK


Max Tensile Stress (wind upward) = 0.8733 Mpa >= -3.516 Mpa OK

1.1) Frequent Combination LC-SF1.1 : At day 92 Structure open to LL + temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.6164 0.4478 0.3 -0.434 -0.394 -0.633 -3.558 -5.1144 -5.369
Girder Gbottom Mpa 7.7954 7.9731 8.1287 11.655 17.224 17.478 20.67 22.488 22.89

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.345
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.9803 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.4912 4.4564 4.77
Girder Gbottom Mpa 0.0017 -0.098 -0.164 -0.88 -1.851 -1.942 -3.505 -4.4747 -4.789

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0115 0.0211 0.1118 0.2074 0.2199 0.3759 0.4694 0.5
Deck Dbottom Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.2833 0.3538 0.377
Gtop Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.2833 0.3538 0.377
Girder Gbottom Mpa 0 -0.016 -0.029 -0.175 -0.378 -0.401 -0.685 -0.8554 -0.911
F) Stresses due to Live load (Without SV) Load factor = 0.75
Dtop Mpa 0 0.0564 0.1105 0.6175 1.1577 1.2825 2.0459 2.4197 2.646
Deck Dbottom Mpa 0 0.0448 0.0878 0.479 0.8725 0.9665 1.5418 1.8236 1.994
Gtop Mpa 0 0.0448 0.0878 0.479 0.8725 0.9665 1.5418 1.8236 1.994
Girder Gbottom Mpa 0 -0.077 -0.15 -0.969 -2.11 -2.337 -3.728 -4.4092 -4.821
F.1) Stresses due to Live load (With SV) Load factor = 0.75

EPC Contractor-M/s Krishna Constructions 153


Design ch-109+720
Design of PSC Girder

Dtop Mpa 0 0.0367 0.0747 0.4269 0.8079 0.8619 1.5241 1.9894 2.057
Deck Dbottom Mpa 0 0.0291 0.0593 0.3312 0.6089 0.6495 1.1486 1.4992 1.551
Gtop Mpa 0 0.0291 0.0593 0.3312 0.6089 0.6495 1.1486 1.4992 1.551
Girder Gbottom Mpa 0 -0.05 -0.102 -0.67 -1.472 -1.57 -2.777 -3.625 -3.749

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.173 -0.173 -0.173 -0.154 -0.116 -0.116 -0.116 -0.1158 -0.116
Deck Dbottom Mpa -0.213 -0.213 -0.213 -0.195 -0.158 -0.158 -0.158 -0.1585 -0.158
Gtop Mpa 0.2681 0.2681 0.2681 0.2857 0.3223 0.3223 0.3223 0.3223 0.322
Girder Gbottom Mpa -0.144 -0.144 -0.144 -0.141 -0.124 -0.124 -0.124 -0.1242 -0.124
H) +ve temperature stresses Load factor = 0.5
Dtop Mpa 2.26 2.26 2.26 2.3498 2.4404 2.4404 2.4404 2.4404 2.44
Deck Dbottom Mpa -0.66 -0.66 -0.66 -0.598 -0.536 -0.536 -0.536 -0.5356 -0.536
Gtop Mpa -0.66 -0.66 -0.66 -0.598 -0.536 -0.536 -0.536 -0.5356 -0.536
Girder Gbottom Mpa 1.4029 1.4029 1.4029 1.1743 0.9436 0.9436 0.9436 0.9436 0.944
Total Stresses (A+B +C+D+E+F+G) (Without SV Loading)
Dtop Mpa 2.0867 2.1546 2.2183 2.9248 3.6897 3.827 4.7464 5.2138 5.47
Deck Dbottom Mpa -0.873 -0.819 -0.768 -0.227 0.3347 0.4381 1.131 1.4832 1.677
Gtop Mpa 0.2134 0.3182 0.3897 1.9887 4.9513 5.0628 6.3333 7.262 7.903
Girder Gbottom Mpa 9.066 8.9251 8.8201 9.3371 11.007 10.764 8.7628 7.588 6.821
Total Stresses (A+B +C+D+E+F+G) (With SV Loading)
Dtop Mpa -0.173 -0.125 -0.077 0.3844 0.8995 0.966 1.7842 2.343 2.442
Deck Dbottom Mpa -0.213 -0.174 -0.137 0.2228 0.6067 0.6568 1.2734 1.6945 1.769
Gtop Mpa 0.8733 0.9624 1.0212 2.4389 5.2233 5.2814 6.4756 7.4733 7.995
Girder Gbottom Mpa 7.6631 7.5491 7.4659 8.4618 10.701 10.587 8.77 7.4286 6.95

Max Compressive stress = 11.007 Mpa < 24 Mpa OK


Max Tensile Stress = 0.2134 Mpa >= -3.516 Mpa OK

1.2) Frequent Combination LC-SF1.2 : At day 92 Structure open to LL - temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.6164 0.4478 0.3 -0.434 -0.394 -0.633 -3.558 -5.1144 -5.369
Girder Gbottom Mpa 7.7954 7.9731 8.1287 11.655 17.224 17.478 20.67 22.488 22.89

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.345
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.9803 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.4912 4.4564 4.77
Girder Gbottom Mpa 0.0017 -0.098 -0.164 -0.88 -1.851 -1.942 -3.505 -4.4747 -4.789

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0115 0.0211 0.1118 0.2074 0.2199 0.3759 0.4694 0.5
Deck Dbottom Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.2833 0.3538 0.377
Gtop Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.2833 0.3538 0.377
Girder Gbottom Mpa 0 -0.016 -0.029 -0.175 -0.378 -0.401 -0.685 -0.8554 -0.911
F) Stresses due to Live load (Without SV) Load factor = 0.75
Dtop Mpa 0 0.0564 0.1105 0.6175 1.1577 1.2825 2.0459 2.4197 2.646
Deck Dbottom Mpa 0 0.0448 0.0878 0.479 0.8725 0.9665 1.5418 1.8236 1.994
Gtop Mpa 0 0.0448 0.0878 0.479 0.8725 0.9665 1.5418 1.8236 1.994
Girder Gbottom Mpa 0 -0.077 -0.15 -0.969 -2.11 -2.337 -3.728 -4.4092 -4.821
F.1) Stresses due to Live load (With SV) Load factor = 0.75
Dtop Mpa 0 0.0367 0.0747 0.4269 0.8079 0.8619 1.5241 1.9894 2.057
Deck

EPC Contractor-M/s Krishna Constructions 154


Design ch-109+720
Design of PSC Girder

Deck Dbottom Mpa 0 0.0291 0.0593 0.3312 0.6089 0.6495 1.1486 1.4992 1.551
Gtop Mpa 0 0.0291 0.0593 0.3312 0.6089 0.6495 1.1486 1.4992 1.551
Girder Gbottom Mpa 0 -0.05 -0.102 -0.67 -1.472 -1.57 -2.777 -3.625 -3.749

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.173 -0.173 -0.173 -0.154 -0.116 -0.116 -0.116 -0.1158 -0.116
Deck Dbottom Mpa -0.213 -0.213 -0.213 -0.195 -0.158 -0.158 -0.158 -0.1585 -0.158
Gtop Mpa 0.2681 0.2681 0.2681 0.2857 0.3223 0.3223 0.3223 0.3223 0.322
Girder Gbottom Mpa -0.144 -0.144 -0.144 -0.141 -0.124 -0.124 -0.124 -0.1242 -0.124
H) -ve temperature stresses Load factor = 0.5
Dtop Mpa -1.416 -1.416 -1.416 -1.37 -1.323 -1.323 -1.323 -1.3231 -1.323
Deck Dbottom Mpa 0.3251 0.3251 0.3251 0.3806 0.4366 0.4366 0.4366 0.4366 0.437
Gtop Mpa 0.3251 0.3251 0.3251 0.3806 0.4366 0.4366 0.4366 0.4366 0.437
Girder Gbottom Mpa -1.589 -1.589 -1.589 -1.436 -1.282 -1.282 -1.282 -1.2819 -1.282
Total Stresses (A+B +C+D+E+F+G) (Without SV Loading)
Dtop Mpa -1.589 -1.521 -1.457 -0.795 -0.074 0.0635 0.9829 1.4503 1.707
Deck Dbottom Mpa 0.1124 0.1663 0.2169 0.7512 1.3069 1.4104 2.1032 2.4555 2.649
Gtop Mpa 1.1984 1.3032 1.3747 2.9673 5.9235 6.0351 7.3055 8.2343 8.876
Girder Gbottom Mpa 6.0737 5.9328 5.8278 6.7264 8.7817 8.5385 6.5373 5.3625 4.596
Total Stresses (A+B +C+D+E+F+G) (With SV Loading)
Dtop Mpa -0.173 -0.125 -0.077 0.3844 0.8995 0.966 1.7842 2.343 2.442
Deck Dbottom Mpa -0.213 -0.174 -0.137 0.2228 0.6067 0.6568 1.2734 1.6945 1.769
Gtop Mpa 0.8733 0.9624 1.0212 2.4389 5.2233 5.2814 6.4756 7.4733 7.995
Girder Gbottom Mpa 7.6631 7.5491 7.4659 8.4618 10.701 10.587 8.77 7.4286 6.95

Max Compressive stress = 10.701 Mpa < 24 Mpa OK


Max Tensile Stress = 0.8733 Mpa >= -3.516 Mpa OK

1.3) Frequent Combination LC-SF1.3 : At day 92 Structure open to LL + temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.6164 0.4478 0.3 -0.434 -0.394 -0.633 -3.558 -5.1144 -5.369
Girder Gbottom Mpa 7.7954 7.9731 8.1287 11.655 17.224 17.478 20.67 22.488 22.89

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.345
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.9803 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.4912 4.4564 4.77
Girder Gbottom Mpa 0.0017 -0.098 -0.164 -0.88 -1.851 -1.942 -3.505 -4.4747 -4.789

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0115 0.0211 0.1118 0.2074 0.2199 0.3759 0.4694 0.5
Deck Dbottom Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.2833 0.3538 0.377
Gtop Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.2833 0.3538 0.377
Girder Gbottom Mpa 0 -0.016 -0.029 -0.175 -0.378 -0.401 -0.685 -0.8554 -0.911
F) Stresses due to Live load (Without SV) Load factor = 0.2
Dtop Mpa 0 0.0151 0.0295 0.1647 0.3087 0.342 0.5456 0.6453 0.706
Deck Dbottom Mpa 0 0.012 0.0234 0.1277 0.2327 0.2577 0.4111 0.4863 0.532
Gtop Mpa 0 0.012 0.0234 0.1277 0.2327 0.2577 0.4111 0.4863 0.532
Girder Gbottom Mpa 0 -0.02 -0.04 -0.258 -0.563 -0.623 -0.994 -1.1758 -1.286
F.1) Stresses due to Live load (With SV) Load factor = 0.2
Dtop Mpa 0 0.0098 0.0199 0.1138 0.2155 0.2298 0.4064 0.5305 0.549
Deck Dbottom Mpa 0 0.0078 0.0158 0.0883 0.1624 0.1732 0.3063 0.3998 0.413
Gtop Mpa 0 0.0078 0.0158 0.0883 0.1624 0.1732 0.3063 0.3998 0.413
Girder

EPC Contractor-M/s Krishna Constructions 155


Design ch-109+720
Design of PSC Girder

Girder Gbottom Mpa 0 -0.013 -0.027 -0.179 -0.393 -0.419 -0.741 -0.9667 -1

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.173 -0.173 -0.173 -0.154 -0.116 -0.116 -0.116 -0.1158 -0.116
Deck Dbottom Mpa -0.213 -0.213 -0.213 -0.195 -0.158 -0.158 -0.158 -0.1585 -0.158
Gtop Mpa 0.2681 0.2681 0.2681 0.2857 0.3223 0.3223 0.3223 0.3223 0.322
Girder Gbottom Mpa -0.144 -0.144 -0.144 -0.141 -0.124 -0.124 -0.124 -0.1242 -0.124
H) +ve temperature stresses Load factor = 0.6
Dtop Mpa 2.712 2.712 2.712 2.8197 2.9285 2.9285 2.9285 2.9285 2.928
Deck Dbottom Mpa -0.792 -0.792 -0.792 -0.718 -0.643 -0.643 -0.643 -0.6427 -0.643
Gtop Mpa -0.792 -0.792 -0.792 -0.718 -0.643 -0.643 -0.643 -0.6427 -0.643
Girder Gbottom Mpa 1.6835 1.6835 1.6835 1.4091 1.1323 1.1323 1.1323 1.1323 1.132
Total Stresses (A+B +C+D+E+F+G) (Without SV Loading)
Dtop Mpa 2.5387 2.5652 2.5893 2.9419 3.3288 3.3746 3.7342 3.9274 4.018
Deck Dbottom Mpa -1.005 -0.984 -0.964 -0.698 -0.412 -0.378 -0.107 0.0388 0.107
Gtop Mpa 0.0814 0.1534 0.1934 1.5178 4.2044 4.2469 5.0955 5.8176 6.334
Girder Gbottom Mpa 9.3466 9.262 9.2109 10.283 12.743 12.666 11.685 11.01 10.55
Total Stresses (A+B +C+D+E+F+G) (With SV Loading)
Dtop Mpa -0.173 -0.152 -0.132 0.0713 0.307 0.3339 0.6665 0.8842 0.933
Deck Dbottom Mpa -0.213 -0.196 -0.18 -0.02 0.1602 0.1804 0.4311 0.5951 0.632
Gtop Mpa 0.8733 0.9411 0.9777 2.196 4.7768 4.8051 5.6334 6.3739 6.858
Girder Gbottom Mpa 7.6631 7.5857 7.5404 8.9531 11.781 11.739 10.807 10.087 9.7

Max Compressive stress = 12.743 Mpa < 24 Mpa OK


Max Tensile Stress = 0.0814 Mpa >= -3.516 Mpa OK

1.4) Frequent Combination LC-SF1.4 : At day 92 Structure open to LL - temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.6164 0.4478 0.3 -0.434 -0.394 -0.633 -3.558 -5.1144 -5.369
Girder Gbottom Mpa 7.7954 7.9731 8.1287 11.655 17.224 17.478 20.67 22.488 22.89

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.345
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.9803 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.4912 4.4564 4.77
Girder Gbottom Mpa 0.0017 -0.098 -0.164 -0.88 -1.851 -1.942 -3.505 -4.4747 -4.789

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0115 0.0211 0.1118 0.2074 0.2199 0.3759 0.4694 0.5
Deck Dbottom Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.2833 0.3538 0.377
Gtop Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.2833 0.3538 0.377
Girder Gbottom Mpa 0 -0.016 -0.029 -0.175 -0.378 -0.401 -0.685 -0.8554 -0.911
F) Stresses due to Live load (Without SV) Load factor = 0.2
Dtop Mpa 0 0.0151 0.0295 0.1647 0.3087 0.342 0.5456 0.6453 0.706
Deck Dbottom Mpa 0 0.012 0.0234 0.1277 0.2327 0.2577 0.4111 0.4863 0.532
Gtop Mpa 0 0.012 0.0234 0.1277 0.2327 0.2577 0.4111 0.4863 0.532
Girder Gbottom Mpa 0 -0.02 -0.04 -0.258 -0.563 -0.623 -0.994 -1.1758 -1.286
F.1) Stresses due to Live load (With SV) Load factor = 0.2
Dtop Mpa 0 0.0098 0.0199 0.1138 0.2155 0.2298 0.4064 0.5305 0.549
Deck Dbottom Mpa 0 0.0078 0.0158 0.0883 0.1624 0.1732 0.3063 0.3998 0.413
Gtop Mpa 0 0.0078 0.0158 0.0883 0.1624 0.1732 0.3063 0.3998 0.413
Girder Gbottom Mpa 0 -0.013 -0.027 -0.179 -0.393 -0.419 -0.741 -0.9667 -1

EPC Contractor-M/s Krishna Constructions 156


Design ch-109+720
Design of PSC Girder

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.173 -0.173 -0.173 -0.154 -0.116 -0.116 -0.116 -0.1158 -0.116
Deck Dbottom Mpa -0.213 -0.213 -0.213 -0.195 -0.158 -0.158 -0.158 -0.1585 -0.158
Gtop Mpa 0.2681 0.2681 0.2681 0.2857 0.3223 0.3223 0.3223 0.3223 0.322
Girder Gbottom Mpa -0.144 -0.144 -0.144 -0.141 -0.124 -0.124 -0.124 -0.1242 -0.124
H) -ve temperature stresses Load factor = 0.6
Dtop Mpa -1.699 -1.699 -1.699 -1.643 -1.588 -1.588 -1.588 -1.5877 -1.588
Deck Dbottom Mpa 0.3901 0.3901 0.3901 0.4567 0.524 0.524 0.524 0.524 0.524
Gtop Mpa 0.3901 0.3901 0.3901 0.4567 0.524 0.524 0.524 0.524 0.524
Girder Gbottom Mpa -1.907 -1.907 -1.907 -1.724 -1.538 -1.538 -1.538 -1.5383 -1.538
Total Stresses (A+B +C+D+E+F+G) (Without SV Loading)
Dtop Mpa -1.872 -1.845 -1.821 -1.521 -1.187 -1.142 -0.782 -0.5888 -0.498
Deck Dbottom Mpa 0.1774 0.1985 0.2176 0.4761 0.7544 0.7889 1.0599 1.2055 1.274
Gtop Mpa 1.2634 1.3353 1.3753 2.6922 5.3711 5.4136 6.2622 6.9843 7.501
Girder Gbottom Mpa 5.7558 5.6712 5.6201 7.1498 10.072 9.9959 9.0147 8.3396 7.875
Total Stresses (A+B +C+D+E+F+G) (With SV Loading)
Dtop Mpa -0.173 -0.152 -0.132 0.0713 0.307 0.3339 0.6665 0.8842 0.933
Deck Dbottom Mpa -0.213 -0.196 -0.18 -0.02 0.1602 0.1804 0.4311 0.5951 0.632
Gtop Mpa 0.8733 0.9411 0.9777 2.196 4.7768 4.8051 5.6334 6.3739 6.858
Girder Gbottom Mpa 7.6631 7.5857 7.5404 8.9531 11.781 11.739 10.807 10.087 9.7

Max Compressive stress = 11.781 Mpa < 24 Mpa OK


Max Tensile Stress = 0.8733 Mpa >= -3.516 Mpa OK

2) Frequent Combination LC-SF2 : At day 36500


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.6515 0.5002 0.3677 -0.25 -0.148 -0.357 -2.927 -4.2979 -4.517
Girder Gbottom Mpa 6.8121 6.9712 7.11 10.101 14.632 14.852 17.651 19.239 19.58

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.345
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.9803 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.4912 4.4564 4.77
Girder Gbottom Mpa 0.0017 -0.098 -0.164 -0.88 -1.851 -1.942 -3.505 -4.4747 -4.789

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.1) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.2) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0115 0.0211 0.1118 0.2074 0.2199 0.3759 0.4694 0.5
Deck Dbottom Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.2833 0.3538 0.377
Gtop Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.2833 0.3538 0.377
Girder Gbottom Mpa 0 -0.016 -0.029 -0.175 -0.378 -0.401 -0.685 -0.8554 -0.911
F) Stresses due to Live load (Without SV) Load factor = 0.75
Dtop Mpa 0 0.0564 0.1105 0.6175 1.1577 1.2825 2.0459 2.4197 2.646
Deck Dbottom Mpa 0 0.0448 0.0878 0.479 0.8725 0.9665 1.5418 1.8236 1.994
Gtop Mpa 0 0.0448 0.0878 0.479 0.8725 0.9665 1.5418 1.8236 1.994
Girder Gbottom Mpa 0 -0.077 -0.15 -0.969 -2.11 -2.337 -3.728 -4.4092 -4.821
F.1) Stresses due to Live load (With SV) Load factor = 0.75
Dtop Mpa 0 0.0367 0.0747 0.4269 0.8079 0.8619 1.5241 1.9894 2.057
Deck Dbottom Mpa 0 0.0291 0.0593 0.3312 0.6089 0.6495 1.1486 1.4992 1.551
Gtop Mpa 0 0.0291 0.0593 0.3312 0.6089 0.6495 1.1486 1.4992 1.551
Girder Gbottom Mpa 0 -0.05 -0.102 -0.67 -1.472 -1.57 -2.777 -3.625 -3.749

EPC Contractor-M/s Krishna Constructions 157


Design ch-109+720
Design of PSC Girder

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.713 -0.713 -0.713 -0.635 -0.477 -0.477 -0.477 -0.4765 -0.477
Deck Dbottom Mpa -0.875 -0.875 -0.875 -0.803 -0.652 -0.652 -0.652 -0.6523 -0.652
Gtop Mpa 1.1035 1.1035 1.1035 1.1759 1.3266 1.3266 1.3266 1.3266 1.327
Girder Gbottom Mpa -0.592 -0.592 -0.592 -0.58 -0.511 -0.511 -0.511 -0.511 -0.511
Total Stresses (A+B +C+D+E+F+G) (Without SV Loading)
Dtop Mpa -0.713 -0.645 -0.582 0.0943 0.8886 1.0258 1.9452 2.4126 2.669
Deck Dbottom Mpa -0.875 -0.822 -0.771 -0.237 0.3765 0.4799 1.1728 1.525 1.718
Gtop Mpa 1.7438 1.8658 1.9527 3.6609 6.7377 6.8789 8.5045 9.6184 10.29
Girder Gbottom Mpa 6.2317 6.0723 5.9504 6.1695 7.0848 6.8076 4.4135 3.0084 2.176
Total Stresses (A+B +C+D+E+F+G) (With SV Loading)
Dtop Mpa -0.713 -0.665 -0.617 -0.096 0.5388 0.6052 1.4234 1.9823 2.081
Deck Dbottom Mpa -0.875 -0.837 -0.799 -0.385 0.1129 0.1629 0.7796 1.2007 1.275
Gtop Mpa 1.7438 1.8501 1.9242 3.5131 6.4741 6.5619 8.1112 9.2941 9.851
Girder Gbottom Mpa 6.2317 6.0991 5.9991 6.4686 7.7221 7.574 5.3643 3.7926 3.249

Max Compressive stress = 10.295 Mpa < 24 Mpa OK


Max Tensile Stress = 1.7438 Mpa >= -3.516 Mpa OK

2.1) Frequent Combination LC-SF2.1 : At day 36500 + temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.6515 0.5002 0.3677 -0.25 -0.148 -0.357 -2.927 -4.2979 -4.517
Girder Gbottom Mpa 6.8121 6.9712 7.11 10.101 14.632 14.852 17.651 19.239 19.58

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.345
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.9803 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.4912 4.4564 4.77
Girder Gbottom Mpa 0.0017 -0.098 -0.164 -0.88 -1.851 -1.942 -3.505 -4.4747 -4.789

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.1) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.2) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0115 0.0211 0.1118 0.2074 0.2199 0.3759 0.4694 0.5
Deck Dbottom Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.2833 0.3538 0.377
Gtop Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.2833 0.3538 0.377
Girder Gbottom Mpa 0 -0.016 -0.029 -0.175 -0.378 -0.401 -0.685 -0.8554 -0.911
F) Stresses due to Live load (Without SV) Load factor = 0.75
Dtop Mpa 0 0.0564 0.1105 0.6175 1.1577 1.2825 2.0459 2.4197 2.646
Deck Dbottom Mpa 0 0.0448 0.0878 0.479 0.8725 0.9665 1.5418 1.8236 1.994
Gtop Mpa 0 0.0448 0.0878 0.479 0.8725 0.9665 1.5418 1.8236 1.994
Girder Gbottom Mpa 0 -0.077 -0.15 -0.969 -2.11 -2.337 -3.728 -4.4092 -4.821
F.1) Stresses due to Live load (With SV) Load factor = 0.75
Dtop Mpa 0 0.0367 0.0747 0.4269 0.8079 0.8619 1.5241 1.9894 2.057
Deck Dbottom Mpa 0 0.0291 0.0593 0.3312 0.6089 0.6495 1.1486 1.4992 1.551
Gtop Mpa 0 0.0291 0.0593 0.3312 0.6089 0.6495 1.1486 1.4992 1.551
Girder Gbottom Mpa 0 -0.05 -0.102 -0.67 -1.472 -1.57 -2.777 -3.625 -3.749
G) Stresses due to differential shrinkage Load factor = 1
Dtop Mpa -0.713 -0.713 -0.713 -0.635 -0.477 -0.477 -0.477 -0.4765 -0.477
Deck Dbottom Mpa -0.875 -0.875 -0.875 -0.803 -0.652 -0.652 -0.652 -0.6523 -0.652
Gtop Mpa 1.1035 1.1035 1.1035 1.1759 1.3266 1.3266 1.3266 1.3266 1.327
Girder Gbottom Mpa -0.592 -0.592 -0.592 -0.58 -0.511 -0.511 -0.511 -0.511 -0.511
H) +ve temperature stresses Load factor = 0.5
Dtop Mpa 2.26 2.26 2.26 2.3498 2.4404 2.4404 2.4404 2.4404 2.44
Deck

EPC Contractor-M/s Krishna Constructions 158


Design ch-109+720
Design of PSC Girder

Deck Dbottom Mpa -0.66 -0.66 -0.66 -0.598 -0.536 -0.536 -0.536 -0.5356 -0.536
Gtop Mpa -0.66 -0.66 -0.66 -0.598 -0.536 -0.536 -0.536 -0.5356 -0.536
Girder Gbottom Mpa 1.4029 1.4029 1.4029 1.1743 0.9436 0.9436 0.9436 0.9436 0.944
Total Stresses (A+B +C+D+E+F+G) (Without SV Loading)
Dtop Mpa 1.5467 1.6146 1.6783 2.444 3.329 3.4662 4.3856 4.853 5.11
Deck Dbottom Mpa -1.535 -1.481 -1.431 -0.835 -0.159 -0.056 0.6372 0.9894 1.183
Gtop Mpa 1.0839 1.2059 1.2928 3.0628 6.2021 6.3433 7.9688 9.0828 9.759
Girder Gbottom Mpa 7.6346 7.4751 7.3533 7.3438 8.0284 7.7512 5.3571 3.952 3.12
Total Stresses (A+B +C+D+E+F+G) (With SV Loading)
Dtop Mpa -0.713 -0.665 -0.617 -0.096 0.5388 0.6052 1.4234 1.9823 2.081
Deck Dbottom Mpa -0.875 -0.837 -0.799 -0.385 0.1129 0.1629 0.7796 1.2007 1.275
Gtop Mpa 1.7438 1.8501 1.9242 3.5131 6.4741 6.5619 8.1112 9.2941 9.851
Girder Gbottom Mpa 6.2317 6.0991 5.9991 6.4686 7.7221 7.574 5.3643 3.7926 3.249

Max Compressive stress = 9.8513 Mpa < 24 Mpa OK


Max Tensile Stress = 1.0839 Mpa >= -3.516 Mpa OK

2.2) Frequent Combination LC-SF2.2 : At day 36500 - temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.6515 0.5002 0.3677 -0.25 -0.148 -0.357 -2.927 -4.2979 -4.517
Girder Gbottom Mpa 6.8121 6.9712 7.11 10.101 14.632 14.852 17.651 19.239 19.58

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.345
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.9803 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.4912 4.4564 4.77
Girder Gbottom Mpa 0.0017 -0.098 -0.164 -0.88 -1.851 -1.942 -3.505 -4.4747 -4.789

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.1) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.2) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0115 0.0211 0.1118 0.2074 0.2199 0.3759 0.4694 0.5
Deck Dbottom Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.2833 0.3538 0.377
Gtop Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.2833 0.3538 0.377
Girder Gbottom Mpa 0 -0.016 -0.029 -0.175 -0.378 -0.401 -0.685 -0.8554 -0.911
F) Stresses due to Live load (Without SV) Load factor = 0.75
Dtop Mpa 0 0.0564 0.1105 0.6175 1.1577 1.2825 2.0459 2.4197 2.646
Deck Dbottom Mpa 0 0.0448 0.0878 0.479 0.8725 0.9665 1.5418 1.8236 1.994
Gtop Mpa 0 0.0448 0.0878 0.479 0.8725 0.9665 1.5418 1.8236 1.994
Girder Gbottom Mpa 0 -0.077 -0.15 -0.969 -2.11 -2.337 -3.728 -4.4092 -4.821
F.1) Stresses due to Live load (With SV) Load factor = 0.75
Dtop Mpa 0 0.0367 0.0747 0.4269 0.8079 0.8619 1.5241 1.9894 2.057
Deck Dbottom Mpa 0 0.0291 0.0593 0.3312 0.6089 0.6495 1.1486 1.4992 1.551
Gtop Mpa 0 0.0291 0.0593 0.3312 0.6089 0.6495 1.1486 1.4992 1.551
Girder Gbottom Mpa 0 -0.05 -0.102 -0.67 -1.472 -1.57 -2.777 -3.625 -3.749
G) Stresses due to differential shrinkage Load factor = 1
Dtop Mpa -0.713 -0.713 -0.713 -0.635 -0.477 -0.477 -0.477 -0.4765 -0.477
Deck Dbottom Mpa -0.875 -0.875 -0.875 -0.803 -0.652 -0.652 -0.652 -0.6523 -0.652
Gtop Mpa 1.1035 1.1035 1.1035 1.1759 1.3266 1.3266 1.3266 1.3266 1.327
Girder Gbottom Mpa -0.592 -0.592 -0.592 -0.58 -0.511 -0.511 -0.511 -0.511 -0.511
H) -ve temperature stresses Load factor = 0.5
Dtop Mpa -1.416 -1.416 -1.416 -1.37 -1.323 -1.323 -1.323 -1.3231 -1.323
Deck Dbottom Mpa 0.3251 0.3251 0.3251 0.3806 0.4366 0.4366 0.4366 0.4366 0.437
Gtop Mpa 0.3251 0.3251 0.3251 0.3806 0.4366 0.4366 0.4366 0.4366 0.437
Girder

EPC Contractor-M/s Krishna Constructions 159


Design ch-109+720
Design of PSC Girder

Girder Gbottom Mpa -1.589 -1.589 -1.589 -1.436 -1.282 -1.282 -1.282 -1.2819 -1.282
Total Stresses (A+B +C+D+E+F+G) (Without SV Loading)
Dtop Mpa -2.129 -2.061 -1.997 -1.275 -0.435 -0.297 0.6221 1.0895 1.346
Deck Dbottom Mpa -0.55 -0.496 -0.446 0.1433 0.8131 0.9166 1.6094 1.9617 2.155
Gtop Mpa 2.0689 2.1909 2.2778 4.0415 7.1743 7.3155 8.9411 10.055 10.73
Girder Gbottom Mpa 4.6423 4.4828 4.361 4.7332 5.8029 5.5257 3.1316 1.7265 0.894
Total Stresses (A+B +C+D+E+F+G) (With SV Loading)
Dtop Mpa -0.713 -0.665 -0.617 -0.096 0.5388 0.6052 1.4234 1.9823 2.081
Deck Dbottom Mpa -0.875 -0.837 -0.799 -0.385 0.1129 0.1629 0.7796 1.2007 1.275
Gtop Mpa 1.7438 1.8501 1.9242 3.5131 6.4741 6.5619 8.1112 9.2941 9.851
Girder Gbottom Mpa 6.2317 6.0991 5.9991 6.4686 7.7221 7.574 5.3643 3.7926 3.249

Max Compressive stress = 10.732 Mpa < 24 Mpa OK


Max Tensile Stress = 0.8945 Mpa >= -3.516 Mpa OK

2.3) Frequent Combination LC-SF2.3 : At day 36500 + temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.6515 0.5002 0.3677 -0.25 -0.148 -0.357 -2.927 -4.2979 -4.517
Girder Gbottom Mpa 6.8121 6.9712 7.11 10.101 14.632 14.852 17.651 19.239 19.58

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.345
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.9803 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.4912 4.4564 4.77
Girder Gbottom Mpa 0.0017 -0.098 -0.164 -0.88 -1.851 -1.942 -3.505 -4.4747 -4.789

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.1) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.2) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0115 0.0211 0.1118 0.2074 0.2199 0.3759 0.4694 0.5
Deck Dbottom Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.2833 0.3538 0.377
Gtop Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.2833 0.3538 0.377
Girder Gbottom Mpa 0 -0.016 -0.029 -0.175 -0.378 -0.401 -0.685 -0.8554 -0.911
F) Stresses due to Live load (Without SV) Load factor = 0.2
Dtop Mpa 0 0.0151 0.0295 0.1647 0.3087 0.342 0.5456 0.6453 0.706
Deck Dbottom Mpa 0 0.012 0.0234 0.1277 0.2327 0.2577 0.4111 0.4863 0.532
Gtop Mpa 0 0.012 0.0234 0.1277 0.2327 0.2577 0.4111 0.4863 0.532
Girder Gbottom Mpa 0 -0.02 -0.04 -0.258 -0.563 -0.623 -0.994 -1.1758 -1.286
F.1) Stresses due to Live load (With SV) Load factor = 0.2
Dtop Mpa 0 0.0098 0.0199 0.1138 0.2155 0.2298 0.4064 0.5305 0.549
Deck Dbottom Mpa 0 0.0078 0.0158 0.0883 0.1624 0.1732 0.3063 0.3998 0.413
Gtop Mpa 0 0.0078 0.0158 0.0883 0.1624 0.1732 0.3063 0.3998 0.413
Girder Gbottom Mpa 0 -0.013 -0.027 -0.179 -0.393 -0.419 -0.741 -0.9667 -1

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.713 -0.713 -0.713 -0.635 -0.477 -0.477 -0.477 -0.4765 -0.477
Deck Dbottom Mpa -0.875 -0.875 -0.875 -0.803 -0.652 -0.652 -0.652 -0.6523 -0.652
Gtop Mpa 1.1035 1.1035 1.1035 1.1759 1.3266 1.3266 1.3266 1.3266 1.327
Girder Gbottom Mpa -0.592 -0.592 -0.592 -0.58 -0.511 -0.511 -0.511 -0.511 -0.511
H) +ve temperature stresses Load factor = 0.6
Dtop Mpa 2.712 2.712 2.712 2.8197 2.9285 2.9285 2.9285 2.9285 2.928
Deck Dbottom Mpa -0.792 -0.792 -0.792 -0.718 -0.643 -0.643 -0.643 -0.6427 -0.643
Gtop Mpa -0.792 -0.792 -0.792 -0.718 -0.643 -0.643 -0.643 -0.6427 -0.643
Girder Gbottom Mpa 1.6835 1.6835 1.6835 1.4091 1.1323 1.1323 1.1323 1.1323 1.132

EPC Contractor-M/s Krishna Constructions 160


Design ch-109+720
Design of PSC Girder

Total Stresses (A+B +C+D+E+F+G) (Without SV Loading)


Dtop Mpa 1.9987 2.0252 2.0493 2.4612 2.968 3.0138 3.3734 3.5666 3.657
Deck Dbottom Mpa -1.667 -1.646 -1.627 -1.306 -0.906 -0.872 -0.601 -0.455 -0.387
Gtop Mpa 0.9519 1.0411 1.0965 2.592 5.4551 5.5274 6.7311 7.6384 8.19
Girder Gbottom Mpa 7.9152 7.812 7.744 8.2893 9.7641 9.6536 8.2796 7.3741 6.844
Total Stresses (A+B +C+D+E+F+G) (With SV Loading)
Dtop Mpa -0.713 -0.692 -0.672 -0.409 -0.054 -0.027 0.3058 0.5234 0.572
Deck Dbottom Mpa -0.875 -0.859 -0.843 -0.628 -0.334 -0.313 -0.063 0.1013 0.138
Gtop Mpa 1.7438 1.8287 1.8808 3.2702 6.0276 6.0856 7.2689 8.1946 8.714
Girder Gbottom Mpa 6.2317 6.1357 6.0736 6.9599 8.8018 8.7257 7.4008 6.4509 5.998

Max Compressive stress = 9.7641 Mpa < 24 Mpa OK


Max Tensile Stress = 0.9519 Mpa >= -3.516 Mpa OK

2.4) Frequent Combination LC-SF2.4 : At day 36500 - temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.6515 0.5002 0.3677 -0.25 -0.148 -0.357 -2.927 -4.2979 -4.517
Girder Gbottom Mpa 6.8121 6.9712 7.11 10.101 14.632 14.852 17.651 19.239 19.58

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.345
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.9803 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.4912 4.4564 4.77
Girder Gbottom Mpa 0.0017 -0.098 -0.164 -0.88 -1.851 -1.942 -3.505 -4.4747 -4.789

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.1) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.2) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0115 0.0211 0.1118 0.2074 0.2199 0.3759 0.4694 0.5
Deck Dbottom Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.2833 0.3538 0.377
Gtop Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.2833 0.3538 0.377
Girder Gbottom Mpa 0 -0.016 -0.029 -0.175 -0.378 -0.401 -0.685 -0.8554 -0.911
F) Stresses due to Live load (Without SV) Load factor = 0.2
Dtop Mpa 0 0.0151 0.0295 0.1647 0.3087 0.342 0.5456 0.6453 0.706
Deck Dbottom Mpa 0 0.012 0.0234 0.1277 0.2327 0.2577 0.4111 0.4863 0.532
Gtop Mpa 0 0.012 0.0234 0.1277 0.2327 0.2577 0.4111 0.4863 0.532
Girder Gbottom Mpa 0 -0.02 -0.04 -0.258 -0.563 -0.623 -0.994 -1.1758 -1.286
F.1) Stresses due to Live load (With SV) Load factor = 0.2
Dtop Mpa 0 0.0098 0.0199 0.1138 0.2155 0.2298 0.4064 0.5305 0.549
Deck Dbottom Mpa 0 0.0078 0.0158 0.0883 0.1624 0.1732 0.3063 0.3998 0.413
Gtop Mpa 0 0.0078 0.0158 0.0883 0.1624 0.1732 0.3063 0.3998 0.413
Girder Gbottom Mpa 0 -0.013 -0.027 -0.179 -0.393 -0.419 -0.741 -0.9667 -1
G) Stresses due to differential shrinkage Load factor = 1
Dtop Mpa -0.713 -0.713 -0.713 -0.635 -0.477 -0.477 -0.477 -0.4765 -0.477
Deck Dbottom Mpa -0.875 -0.875 -0.875 -0.803 -0.652 -0.652 -0.652 -0.6523 -0.652
Gtop Mpa 1.1035 1.1035 1.1035 1.1759 1.3266 1.3266 1.3266 1.3266 1.327
Girder Gbottom Mpa -0.592 -0.592 -0.592 -0.58 -0.511 -0.511 -0.511 -0.511 -0.511
H) -ve temperature stresses Load factor = 0.6
Dtop Mpa -1.699 -1.699 -1.699 -1.643 -1.588 -1.588 -1.588 -1.5877 -1.588
Deck Dbottom Mpa 0.3901 0.3901 0.3901 0.4567 0.524 0.524 0.524 0.524 0.524
Gtop Mpa 0.3901 0.3901 0.3901 0.4567 0.524 0.524 0.524 0.524 0.524
Girder Gbottom Mpa -1.907 -1.907 -1.907 -1.724 -1.538 -1.538 -1.538 -1.5383 -1.538
Total Stresses (A+B +C+D+E+F+G) (Without SV Loading)
Dtop Mpa -2.412 -2.385 -2.361 -2.002 -1.548 -1.502 -1.143 -0.9495 -0.859
Deck

EPC Contractor-M/s Krishna Constructions 161


Design ch-109+720
Design of PSC Girder

Deck Dbottom Mpa -0.485 -0.464 -0.445 -0.132 0.2606 0.2951 0.5661 0.7117 0.78
Gtop Mpa 2.1339 2.223 2.2784 3.7663 6.6218 6.6941 7.8978 8.8051 9.357
Girder Gbottom Mpa 4.3244 4.2212 4.1533 5.1565 7.0935 6.9831 5.609 4.7035 4.174
Total Stresses (A+B +C+D+E+F+G) (With SV Loading)
Dtop Mpa -0.713 -0.692 -0.672 -0.409 -0.054 -0.027 0.3058 0.5234 0.572
Deck Dbottom Mpa -0.875 -0.859 -0.843 -0.628 -0.334 -0.313 -0.063 0.1013 0.138
Gtop Mpa 1.7438 1.8287 1.8808 3.2702 6.0276 6.0856 7.2689 8.1946 8.714
Girder Gbottom Mpa 6.2317 6.1357 6.0736 6.9599 8.8018 8.7257 7.4008 6.4509 5.998

Max Compressive stress = 9.3565 Mpa < 24 Mpa OK


Max Tensile Stress = 1.7438 Mpa >= -3.516 Mpa OK

SUMMARY FOR SLS FREQUENT COMBINATION


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
1) Frequent Combination LC-SF1 : At day 92 Structure open to LL
Total Stresses (A+B)
Gtop Mpa 0.8733 0.9781 1.0496 2.5867 5.4869 5.5984 6.8689 7.7977 8.439
Girder Gbottom Mpa 7.6631 7.5222 7.4172 8.1628 10.064 9.8204 7.8192 6.6444 5.878
1.1) Frequent Combination LC-SF1.1 : At day 92 Structure open to LL + temperature stresses
Total Stresses (A+B)
Gtop Mpa 0.2134 0.3182 0.3897 1.9887 4.9513 5.0628 6.3333 7.262 7.903
Girder Gbottom Mpa 9.066 8.9251 8.8201 9.3371 11.007 10.764 8.7628 7.588 6.821
1.2) Frequent Combination LC-SF1.2 : At day 92 Structure open to LL - temperature stresses
Total Stresses (A+B)
Gtop Mpa 1.1984 1.3032 1.3747 2.9673 5.9235 6.0351 7.3055 8.2343 8.876
Girder Gbottom Mpa 6.0737 5.9328 5.8278 6.7264 8.7817 8.5385 6.5373 5.3625 4.596
1.3) Frequent Combination LC-SF1.3 : At day 92 Structure open to LL + temperature stresses
Total Stresses (A+B)
Gtop Mpa 0.0814 0.1534 0.1934 1.5178 4.2044 4.2469 5.0955 5.8176 6.334
Girder Gbottom Mpa 9.3466 9.262 9.2109 10.283 12.743 12.666 11.685 11.01 10.55
1.4) Frequent Combination LC-SF1.4 : At day 92 Structure open to LL - temperature stresses
Total Stresses (A+B)
Gtop Mpa 1.2634 1.3353 1.3753 2.6922 5.3711 5.4136 6.2622 6.9843 7.501
Girder Gbottom Mpa 5.7558 5.6712 5.6201 7.1498 10.072 9.9959 9.0147 8.3396 7.875
2) Frequent Combination LC-SF2 : At day 36500
Total Stresses (A+B)
Gtop Mpa 1.7438 1.8658 1.9527 3.6609 6.7377 6.8789 8.5045 9.6184 10.29
Girder Gbottom Mpa 6.2317 6.0723 5.9504 6.1695 7.0848 6.8076 4.4135 3.0084 2.176
2.1) Frequent Combination LC-SF2.1 : At day 36500 + temperature stresses
Total Stresses (A+B)
Gtop Mpa 1.0839 1.2059 1.2928 3.0628 6.2021 6.3433 7.9688 9.0828 9.759
Girder Gbottom Mpa 7.6346 7.4751 7.3533 7.3438 8.0284 7.7512 5.3571 3.952 3.12
2.2) Frequent Combination LC-SF2.2 : At day 36500 - temperature stresses
Total Stresses (A+B)
Gtop Mpa 2.0689 2.1909 2.2778 4.0415 7.1743 7.3155 8.9411 10.055 10.73
Girder Gbottom Mpa 4.6423 4.4828 4.361 4.7332 5.8029 5.5257 3.1316 1.7265 0.894
2.3) Frequent Combination LC-SF2.3 : At day 36500 + temperature stresses
Total Stresses (A+B)
Gtop Mpa 0.9519 1.0411 1.0965 2.592 5.4551 5.5274 6.7311 7.6384 8.19
Girder Gbottom Mpa 7.9152 7.812 7.744 8.2893 9.7641 9.6536 8.2796 7.3741 6.844
2.4) Frequent Combination LC-SF2.4 : At day 36500 - temperature stresses
Total Stresses (A+B)
Gtop Mpa 2.1339 2.223 2.2784 3.7663 6.6218 6.6941 7.8978 8.8051 9.357
Girder Gbottom Mpa 4.3244 4.2212 4.1533 5.1565 7.0935 6.9831 5.609 4.7035 4.174

QUASI PERMANENT LOAD COMBINATION


1) QSP Combination LC-SQ1 : At day 92 Structure open to LL
Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.6164 0.4478 0.3 -0.434 -0.394 -0.633 -3.558 -5.1144 -5.369
Girder Gbottom Mpa 7.7954 7.9731 8.1287 11.655 17.224 17.478 20.67 22.488 22.89

EPC Contractor-M/s Krishna Constructions 162


Design ch-109+720
Design of PSC Girder

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.345
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.9803 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.4912 4.4564 4.77
Girder Gbottom Mpa 0.0017 -0.098 -0.164 -0.88 -1.851 -1.942 -3.505 -4.4747 -4.789

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0115 0.0211 0.1118 0.2074 0.2199 0.3759 0.4694 0.5
Deck Dbottom Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.2833 0.3538 0.377
Gtop Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.2833 0.3538 0.377
Girder Gbottom Mpa 0 -0.016 -0.029 -0.175 -0.378 -0.401 -0.685 -0.8554 -0.911
F) Stresses due to Live load Load factor = 0
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.173 -0.173 -0.173 -0.154 -0.116 -0.116 -0.116 -0.1158 -0.116
Deck Dbottom Mpa -0.213 -0.213 -0.213 -0.195 -0.158 -0.158 -0.158 -0.1585 -0.158
Gtop Mpa 0.2681 0.2681 0.2681 0.2857 0.3223 0.3223 0.3223 0.3223 0.322
Girder Gbottom Mpa -0.144 -0.144 -0.144 -0.141 -0.124 -0.124 -0.124 -0.1242 -0.124
Total Stresses (A+B +C+D+E+F+G)
Dtop Mpa -0.173 -0.162 -0.152 -0.043 0.0916 0.1041 0.2601 0.3537 0.384
Deck Dbottom Mpa -0.213 -0.204 -0.196 -0.108 -0.002 0.0072 0.1248 0.1953 0.218
Gtop Mpa 0.8733 0.9333 0.9618 2.1077 4.6144 4.6319 5.3271 5.9741 6.445
Girder Gbottom Mpa 7.6631 7.599 7.5675 9.1318 12.173 12.157 11.547 11.054 10.7

Max Compressive stress = 12.173 Mpa < 24 Mpa OK


Max Tensile Stress = 0.8733 Mpa >= -3.516 Mpa OK

1.1) QSP Combination LC-SQ1.1 : At day 92 Structure open to LL + temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.6164 0.4478 0.3 -0.434 -0.394 -0.633 -3.558 -5.1144 -5.369
Girder Gbottom Mpa 7.7954 7.9731 8.1287 11.655 17.224 17.478 20.67 22.488 22.89

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.345
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.9803 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.4912 4.4564 4.77
Girder Gbottom Mpa 0.0017 -0.098 -0.164 -0.88 -1.851 -1.942 -3.505 -4.4747 -4.789

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0

EPC Contractor-M/s Krishna Constructions 163


Design ch-109+720
Design of PSC Girder

Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0115 0.0211 0.1118 0.2074 0.2199 0.3759 0.4694 0.5
Deck Dbottom Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.2833 0.3538 0.377
Gtop Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.2833 0.3538 0.377
Girder Gbottom Mpa 0 -0.016 -0.029 -0.175 -0.378 -0.401 -0.685 -0.8554 -0.911
F) Stresses due to Live load Load factor = 0
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.173 -0.173 -0.173 -0.154 -0.116 -0.116 -0.116 -0.1158 -0.116
Deck Dbottom Mpa -0.213 -0.213 -0.213 -0.195 -0.158 -0.158 -0.158 -0.1585 -0.158
Gtop Mpa 0.2681 0.2681 0.2681 0.2857 0.3223 0.3223 0.3223 0.3223 0.322
Girder Gbottom Mpa -0.144 -0.144 -0.144 -0.141 -0.124 -0.124 -0.124 -0.1242 -0.124
H) +ve temperature stresses Load factor = 0.5
Dtop Mpa 2.26 2.26 2.26 2.3498 2.4404 2.4404 2.4404 2.4404 2.44
Deck Dbottom Mpa -0.66 -0.66 -0.66 -0.598 -0.536 -0.536 -0.536 -0.5356 -0.536
Gtop Mpa -0.66 -0.66 -0.66 -0.598 -0.536 -0.536 -0.536 -0.5356 -0.536
Girder Gbottom Mpa 1.4029 1.4029 1.4029 1.1743 0.9436 0.9436 0.9436 0.9436 0.944
Total Stresses (A+B +C+D+E+F+G+H)
Dtop Mpa 2.0867 2.0981 2.1078 2.3073 2.532 2.5445 2.7005 2.7941 2.824
Deck Dbottom Mpa -0.873 -0.864 -0.856 -0.706 -0.538 -0.528 -0.411 -0.3403 -0.317
Gtop Mpa 0.2134 0.2734 0.3019 1.5097 4.0788 4.0963 4.7915 5.4385 5.909
Girder Gbottom Mpa 9.066 9.0018 8.9704 10.306 13.117 13.101 12.491 11.997 11.64

Max Compressive stress = 13.117 Mpa < 24 Mpa OK


Max Tensile Stress = 0.2134 Mpa >= -3.516 Mpa OK

1.2) QSP Combination LC-SQ1.2 : At day 92 Structure open to LL - temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.6164 0.4478 0.3 -0.434 -0.394 -0.633 -3.558 -5.1144 -5.369
Girder Gbottom Mpa 7.7954 7.9731 8.1287 11.655 17.224 17.478 20.67 22.488 22.89

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.345
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.9803 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.4912 4.4564 4.77
Girder Gbottom Mpa 0.0017 -0.098 -0.164 -0.88 -1.851 -1.942 -3.505 -4.4747 -4.789

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0115 0.0211 0.1118 0.2074 0.2199 0.3759 0.4694 0.5
Deck Dbottom Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.2833 0.3538 0.377
Gtop Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.2833 0.3538 0.377
Girder Gbottom Mpa 0 -0.016 -0.029 -0.175 -0.378 -0.401 -0.685 -0.8554 -0.911
F) Stresses due to Live load Load factor = 0
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder

EPC Contractor-M/s Krishna Constructions 164


Design ch-109+720
Design of PSC Girder

Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0


G) Stresses due to differential shrinkage Load factor = 1
Dtop Mpa -0.173 -0.173 -0.173 -0.154 -0.116 -0.116 -0.116 -0.1158 -0.116
Deck Dbottom Mpa -0.213 -0.213 -0.213 -0.195 -0.158 -0.158 -0.158 -0.1585 -0.158
Gtop Mpa 0.2681 0.2681 0.2681 0.2857 0.3223 0.3223 0.3223 0.3223 0.322
Girder Gbottom Mpa -0.144 -0.144 -0.144 -0.141 -0.124 -0.124 -0.124 -0.1242 -0.124
H) -ve temperature stresses Load factor = 0.5
Dtop Mpa -1.416 -1.416 -1.416 -1.37 -1.323 -1.323 -1.323 -1.3231 -1.323
Deck Dbottom Mpa 0.3251 0.3251 0.3251 0.3806 0.4366 0.4366 0.4366 0.4366 0.437
Gtop Mpa 0.3251 0.3251 0.3251 0.3806 0.4366 0.4366 0.4366 0.4366 0.437
Girder Gbottom Mpa -1.589 -1.589 -1.589 -1.436 -1.282 -1.282 -1.282 -1.2819 -1.282
Total Stresses (A+B +C+D+E+F+G+H)
Dtop Mpa -1.589 -1.577 -1.568 -1.412 -1.231 -1.219 -1.063 -0.9694 -0.939
Deck Dbottom Mpa 0.1124 0.1215 0.1292 0.2722 0.4344 0.4439 0.5614 0.6319 0.655
Gtop Mpa 1.1984 1.2584 1.2869 2.4883 5.0511 5.0686 5.7637 6.4107 6.882
Girder Gbottom Mpa 6.0737 6.0095 5.9781 7.6954 10.891 10.875 10.265 9.7717 9.417

Max Compressive stress = 10.891 Mpa < 24 Mpa OK


Max Tensile Stress = 1.1984 Mpa >= -3.516 Mpa OK

2) QSP Combination LC-SQ2 : At day 36500


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.6515 0.5002 0.3677 -0.25 -0.148 -0.357 -2.927 -4.2979 -4.517
Girder Gbottom Mpa 6.8121 6.9712 7.11 10.101 14.632 14.852 17.651 19.239 19.58

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.345
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.9803 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.4912 4.4564 4.77
Girder Gbottom Mpa 0.0017 -0.098 -0.164 -0.88 -1.851 -1.942 -3.505 -4.4747 -4.789

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.1) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.2) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0115 0.0211 0.1118 0.2074 0.2199 0.3759 0.4694 0.5
Deck Dbottom Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.2833 0.3538 0.377
Gtop Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.2833 0.3538 0.377
Girder Gbottom Mpa 0 -0.016 -0.029 -0.175 -0.378 -0.401 -0.685 -0.8554 -0.911
F) Stresses due to Live load Load factor = 0
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
G) Stresses due to differential shrinkage Load factor = 1
Dtop Mpa -0.713 -0.713 -0.713 -0.635 -0.477 -0.477 -0.477 -0.4765 -0.477
Deck Dbottom Mpa -0.875 -0.875 -0.875 -0.803 -0.652 -0.652 -0.652 -0.6523 -0.652
Gtop Mpa 1.1035 1.1035 1.1035 1.1759 1.3266 1.3266 1.3266 1.3266 1.327
Girder Gbottom Mpa -0.592 -0.592 -0.592 -0.58 -0.511 -0.511 -0.511 -0.511 -0.511
Total Stresses (A+B +C+D+E+F+G)
Dtop Mpa -0.713 -0.702 -0.692 -0.523 -0.269 -0.257 -0.101 -0.0071 0.023
Deck Dbottom Mpa -0.875 -0.866 -0.859 -0.716 -0.496 -0.487 -0.369 -0.2985 -0.276
Gtop Mpa 1.7438 1.821 1.8649 3.1819 5.8652 5.9124 6.9627 7.7948 8.301
Girder Gbottom Mpa 6.2317 6.149 6.1006 7.1385 9.1944 9.1445 8.1414 7.4176 6.998

EPC Contractor-M/s Krishna Constructions 165


Design ch-109+720
Design of PSC Girder

Max Compressive stress = 9.1944 Mpa < 24 Mpa OK


Max Tensile Stress = 1.7438 Mpa >= -3.516 Mpa OK

2.1) QSP Combination LC-SQ2.1 : At day 36500 + temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.6515 0.5002 0.3677 -0.25 -0.148 -0.357 -2.927 -4.2979 -4.517
Girder Gbottom Mpa 6.8121 6.9712 7.11 10.101 14.632 14.852 17.651 19.239 19.58

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.345
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.9803 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.4912 4.4564 4.77
Girder Gbottom Mpa 0.0017 -0.098 -0.164 -0.88 -1.851 -1.942 -3.505 -4.4747 -4.789

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.1) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.2) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0115 0.0211 0.1118 0.2074 0.2199 0.3759 0.4694 0.5
Deck Dbottom Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.2833 0.3538 0.377
Gtop Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.2833 0.3538 0.377
Girder Gbottom Mpa 0 -0.016 -0.029 -0.175 -0.378 -0.401 -0.685 -0.8554 -0.911
F) Stresses due to Live load Load factor = 0
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
G) Stresses due to differential shrinkage Load factor = 1
Dtop Mpa -0.713 -0.713 -0.713 -0.635 -0.477 -0.477 -0.477 -0.4765 -0.477
Deck Dbottom Mpa -0.875 -0.875 -0.875 -0.803 -0.652 -0.652 -0.652 -0.6523 -0.652
Gtop Mpa 1.1035 1.1035 1.1035 1.1759 1.3266 1.3266 1.3266 1.3266 1.327
Girder Gbottom Mpa -0.592 -0.592 -0.592 -0.58 -0.511 -0.511 -0.511 -0.511 -0.511
H) +ve temperature stresses Load factor = 0.5
Dtop Mpa 2.26 2.26 2.26 2.3498 2.4404 2.4404 2.4404 2.4404 2.44
Deck Dbottom Mpa -0.66 -0.66 -0.66 -0.598 -0.536 -0.536 -0.536 -0.5356 -0.536
Gtop Mpa -0.66 -0.66 -0.66 -0.598 -0.536 -0.536 -0.536 -0.5356 -0.536
Girder Gbottom Mpa 1.4029 1.4029 1.4029 1.1743 0.9436 0.9436 0.9436 0.9436 0.944
Total Stresses (A+B +C+D+E+F+G+H)
Dtop Mpa 1.5467 1.5582 1.5678 1.8265 2.1712 2.1838 2.3398 2.4333 2.464
Deck Dbottom Mpa -1.535 -1.526 -1.519 -1.314 -1.032 -1.022 -0.905 -0.8341 -0.811
Gtop Mpa 1.0839 1.1611 1.205 2.5838 5.3296 5.3768 6.427 7.2592 7.765
Girder Gbottom Mpa 7.6346 7.5519 7.5035 8.3128 10.138 10.088 9.085 8.3611 7.941

Max Compressive stress = 10.138 Mpa < 24 Mpa OK


Max Tensile Stress = 1.0839 Mpa >= -3.516 Mpa OK

2.2) QSP Combination LC-SQ2.2 : At day 36500 - temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.6515 0.5002 0.3677 -0.25 -0.148 -0.357 -2.927 -4.2979 -4.517
Girder Gbottom Mpa 6.8121 6.9712 7.11 10.101 14.632 14.852 17.651 19.239 19.58

EPC Contractor-M/s Krishna Constructions 166


Design ch-109+720
Design of PSC Girder

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.345
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.9803 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.002 0.0954 0.1591 0.8652 1.8436 1.9345 3.4912 4.4564 4.77
Girder Gbottom Mpa 0.0017 -0.098 -0.164 -0.88 -1.851 -1.942 -3.505 -4.4747 -4.789

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.1) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.2) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0115 0.0211 0.1118 0.2074 0.2199 0.3759 0.4694 0.5
Deck Dbottom Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.2833 0.3538 0.377
Gtop Mpa 0 0.0091 0.0168 0.0867 0.1563 0.1657 0.2833 0.3538 0.377
Girder Gbottom Mpa 0 -0.016 -0.029 -0.175 -0.378 -0.401 -0.685 -0.8554 -0.911
F) Stresses due to Live load Load factor = 0
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
G) Stresses due to differential shrinkage Load factor = 1
Dtop Mpa -0.713 -0.713 -0.713 -0.635 -0.477 -0.477 -0.477 -0.4765 -0.477
Deck Dbottom Mpa -0.875 -0.875 -0.875 -0.803 -0.652 -0.652 -0.652 -0.6523 -0.652
Gtop Mpa 1.1035 1.1035 1.1035 1.1759 1.3266 1.3266 1.3266 1.3266 1.327
Girder Gbottom Mpa -0.592 -0.592 -0.592 -0.58 -0.511 -0.511 -0.511 -0.511 -0.511
H) -ve temperature stresses Load factor = 0.5
Dtop Mpa -1.416 -1.416 -1.416 -1.37 -1.323 -1.323 -1.323 -1.3231 -1.323
Deck Dbottom Mpa 0.3251 0.3251 0.3251 0.3806 0.4366 0.4366 0.4366 0.4366 0.437
Gtop Mpa 0.3251 0.3251 0.3251 0.3806 0.4366 0.4366 0.4366 0.4366 0.437
Girder Gbottom Mpa -1.589 -1.589 -1.589 -1.436 -1.282 -1.282 -1.282 -1.2819 -1.282
Total Stresses (A+B +C+D+E+F+G+H)
Dtop Mpa -2.129 -2.117 -2.108 -1.893 -1.592 -1.58 -1.424 -1.3302 -1.3
Deck Dbottom Mpa -0.55 -0.541 -0.534 -0.336 -0.059 -0.05 0.0676 0.1381 0.161
Gtop Mpa 2.0689 2.1461 2.19 3.5625 6.3018 6.349 7.3993 8.2315 8.737
Girder Gbottom Mpa 4.6423 4.5596 4.5112 5.7022 7.9125 7.8626 6.8595 6.1357 5.716

Max Compressive stress = 8.7374 Mpa < 24 Mpa OK


Max Tensile Stress = 2.0689 Mpa >= -3.516 Mpa OK

SUMMARY FOR SLS QUASI PERMANENT LOAD COMBINATION


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
1) QSP Combination LC-SQ1 : At day 92 Structure open to LL
Total Stresses (A+B)
Gtop Mpa 0.8733 0.9333 0.9618 2.1077 4.6144 4.6319 5.3271 5.9741 6.445
Girder Gbottom Mpa 7.6631 7.599 7.5675 9.1318 12.173 12.157 11.547 11.054 10.7
2) QSP Combination LC-SQ2 : At day 36500
Total Stresses (A+B)
Gtop Mpa 1.7438 1.821 1.8649 3.1819 5.8652 5.9124 6.9627 7.7948 8.301
Girder Gbottom Mpa 6.2317 6.149 6.1006 7.1385 9.1944 9.1445 8.1414 7.4176 6.998
1.1) QSP Combination LC-SQ1.1 : At day 92 Structure open to LL + temperature stresses
Total Stresses (A+B)
Gtop Mpa 0.2134 0.2734 0.3019 1.5097 4.0788 4.0963 4.7915 5.4385 5.909
Girder Gbottom Mpa 9.066 9.0018 8.9704 10.306 13.117 13.101 12.491 11.997 11.64
2.1) QSP Combination LC-SQ2.1 : At day 36500 + temperature stresses
Total Stresses (A+B)

EPC Contractor-M/s Krishna Constructions 167


Design ch-109+720
Design of PSC Girder

Gtop Mpa 1.0839 1.1611 1.205 2.5838 5.3296 5.3768 6.427 7.2592 7.765
Girder Gbottom Mpa 7.6346 7.5519 7.5035 8.3128 10.138 10.088 9.085 8.3611 7.941
1.2) QSP Combination LC-SQ1.2 : At day 92 Structure open to LL - temperature stresses
Total Stresses (A+B)
Gtop Mpa 1.1984 1.2584 1.2869 2.4883 5.0511 5.0686 5.7637 6.4107 6.882
Girder Gbottom Mpa 6.0737 6.0095 5.9781 7.6954 10.891 10.875 10.265 9.7717 9.417
2.2) QSP Combination LC-SQ2.2 : At day 36500 - temperature stresses
Total Stresses (A+B)
Gtop Mpa 2.0689 2.1461 2.19 3.5625 6.3018 6.349 7.3993 8.2315 8.737
Girder Gbottom Mpa 4.6423 4.5596 4.5112 5.7022 7.9125 7.8626 6.8595 6.1357 5.716

EPC Contractor-M/s Krishna Constructions 168


Design ch-109+720
Design of PSC Girder

CHECK FOR STRESSES : PRESTRESS WITH SUPERIOR LOAD COMBINATION

SLS STRESS CHECK : RARE COMBINATION SUPERIOR


A) INNER GIRDER SUMMARY OF LOADS
BENDING MOMENT SUMMARY
Section At unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
Precast Beam Tm -0 -0.054 -0.73 8.6895 16.778 84.646 142.08 150.3 253.22 314.97 335.55
Deck Inner Girder Tm -0.043 -0.079 -0.473 5.0827 10.351 61.662 106.55 110.76 198.45 253.61 267.86
Transfer brg. Tm 0 0 0 0 0 0 0 0 0 0 0
SIDL Tm 0 0 0 0 0 0 0 0 0 0 0
Surfacing Tm 0 0 0 1.633 3.079 15.582 27.288 28.941 49.434 61.442 65.692
Wind Load T 0 0 0 1.608 3.031 15.343 26.868 28.495 48.674 60.497 64.681
Live Load (Without SV Loading) Tm 0 0 0 16.179 26.929 114.16 181.79 191.85 256.36 322.14 330.85
Live Load (With SV Loading) Tm 0 0 0 7.128 14.513 79.248 141.54 150.99 267 348.51 360.44

SECTION PROPERTIES
Sections unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Section at m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
Properties of Precast Section
Area m2 1.9297 1.9297 1.9297 1.9297 1.9297 1.4394 0.9447 0.9447 0.9447 0.9447 0.9447
I gross m4 0.872 0.872 0.872 0.872 0.872 0.7401 0.6069 0.6069 0.6069 0.6069 0.6069
yb m 1.1677 1.1677 1.1677 1.1677 1.1677 1.16 1.1524 1.1524 1.1524 1.1524 1.1524
yt m 1.1323 1.1323 1.1323 1.1323 1.1323 1.14 1.1476 1.1476 1.1476 1.1476 1.1476
Properties of Composite Section
Area m2 2.5546 2.5546 2.5546 2.5546 2.5546 2.0643 1.5696 1.5696 1.5696 1.5696 1.5696
I gross m4 1.6031 1.6031 1.6031 1.6031 1.6031 1.4046 1.2043 1.2043 1.2043 1.2043 1.2043
yb m 1.4715 1.4715 1.4715 1.4715 1.4715 1.5619 1.653 1.653 1.653 1.653 1.653
yt m 1.0485 1.0485 1.0485 1.0485 1.0485 0.9581 0.867 0.867 0.867 0.867 0.867
Gtop m 0.8285 0.8285 0.8285 0.8285 0.8285 0.7381 0.647 0.647 0.647 0.647 0.647

STRESSES DUE TO ACTION OF LOADS :


Section At unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
Precast Beam
Gtop Mpa 0 -7E-04 -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0 0.0007 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

Deck Inner Girder


Gtop Mpa -6E-04 -0.001 -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder Gbottom Mpa 0.0006 0.0011 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086

Transfer brg.
Dtop Mpa 0 0 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0 0 0
Stresses Girder
At Gbottom Mpa 0 0 0 0 0 0 0 0 0 0 0

SIDL
Dtop Mpa 0 0 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0 0 0
Stresses Girder
At Gbottom Mpa 0 0 0 0 0 0 0 0 0 0 0

Section At unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
Surfacing
Dtop Mpa 0 0 0 0.0107 0.0201 0.1063 0.1964 0.2083 0.3559 0.4423 0.4729
Deck Dbottom Mpa 0 0 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Gtop Mpa 0 0 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Stresses Girder
At Gbottom Mpa 0 0 0 -0.015 -0.028 -0.173 -0.375 -0.397 -0.679 -0.843 -0.902

EPC Contractor-M/s Krishna Constructions 169


Design ch-109+720
Design of PSC Girder

Live Load (Without SV Loading)


Dtop Mpa 0 0 0 0.1058 0.1761 0.7787 1.3087 1.3811 1.8455 2.319 2.3818
Deck Dbottom Mpa 0 0 0 0.0836 0.1392 0.5999 0.9766 1.0306 1.3772 1.7306 1.7774
Gtop Mpa 0 0 0 0.0836 0.1392 0.5999 0.9766 1.0306 1.3772 1.7306 1.7774
Stresses Girder
At Gbottom Mpa 0 0 0 -0.149 -0.247 -1.269 -2.495 -2.633 -3.519 -4.422 -4.541

Live Load (With SV Loading)


Dtop Mpa 0 0 0 0.0466 0.0949 0.5406 1.0189 1.0869 1.9221 2.5089 2.5948
Deck Dbottom Mpa 0 0 0 0.0368 0.075 0.4165 0.7604 0.8111 1.4343 1.8722 1.9363
Gtop Mpa 0 0 0 0.0368 0.075 0.4165 0.7604 0.8111 1.4343 1.8722 1.9363
Stresses Girder
At Gbottom Mpa 0 0 0 -0.065 -0.133 -0.881 -1.943 -2.073 -3.665 -4.784 -4.948

Wind Load
Dtop Mpa 0 0 0 0.0105 0.0198 0.1047 0.1934 0.2051 0.3504 0.4355 0.4656
Deck Dbottom Mpa 0 0 0 0.0083 0.0157 0.0806 0.1443 0.1531 0.2615 0.325 0.3475
Gtop Mpa 0 0 0 0.0083 0.0157 0.0806 0.1443 0.1531 0.2615 0.325 0.3475
Stresses Girder
At Gbottom Mpa 0 0 0 -0.015 -0.028 -0.171 -0.369 -0.391 -0.668 -0.83 -0.888

STRESSES DUE TO DIFFERENTIAL SHRINKAGE :


At day 63
Dtop Mpa -0.182 -0.182 -0.182 -0.182 -0.182 -0.162 -0.122 -0.122 -0.122 -0.122 -0.122
Deck Dbottom Mpa -0.224 -0.224 -0.224 -0.224 -0.224 -0.205 -0.167 -0.167 -0.167 -0.167 -0.167
Gtop Mpa 0.2822 0.2822 0.2822 0.2822 0.2822 0.3008 0.3393 0.3393 0.3393 0.3393 0.3393
Stresses Girder
At Gbottom Mpa -0.151 -0.151 -0.151 -0.151 -0.151 -0.148 -0.131 -0.131 -0.131 -0.131 -0.131

At day 64
Dtop Mpa -0.182 -0.182 -0.182 -0.182 -0.182 -0.162 -0.122 -0.122 -0.122 -0.122 -0.122
Deck Dbottom Mpa -0.224 -0.224 -0.224 -0.224 -0.224 -0.205 -0.167 -0.167 -0.167 -0.167 -0.167
Gtop Mpa 0.2821 0.2821 0.2821 0.2821 0.2821 0.3007 0.3392 0.3392 0.3392 0.3392 0.3392
Stresses Girder
At Gbottom Mpa -0.151 -0.151 -0.151 -0.151 -0.151 -0.148 -0.131 -0.131 -0.131 -0.131 -0.131

At day 92
Dtop Mpa -0.173 -0.173 -0.173 -0.173 -0.173 -0.154 -0.116 -0.116 -0.116 -0.116 -0.116
Deck Dbottom Mpa -0.213 -0.213 -0.213 -0.213 -0.213 -0.195 -0.158 -0.158 -0.158 -0.158 -0.158
Gtop Mpa 0.2681 0.2681 0.2681 0.2681 0.2681 0.2857 0.3223 0.3223 0.3223 0.3223 0.3223
Stresses Girder
At Gbottom Mpa -0.144 -0.144 -0.144 -0.144 -0.144 -0.141 -0.124 -0.124 -0.124 -0.124 -0.124

At day 36500
Dtop Mpa -0.713 -0.713 -0.713 -0.713 -0.713 -0.635 -0.477 -0.477 -0.477 -0.477 -0.477
Deck Dbottom Mpa -0.875 -0.875 -0.875 -0.875 -0.875 -0.803 -0.652 -0.652 -0.652 -0.652 -0.652
Gtop Mpa 1.1035 1.1035 1.1035 1.1035 1.1035 1.1759 1.3266 1.3266 1.3266 1.3266 1.3266
Stresses Girder
At Gbottom Mpa -0.592 -0.592 -0.592 -0.592 -0.592 -0.58 -0.511 -0.511 -0.511 -0.511 -0.511

STRESSES DUE TO +VE TEMPERATURE STRESSES :


Section At unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
Dtop Mpa 4.52 4.52 4.52 4.6996 4.8808 4.8808 4.8808 4.8808 4.8808
Deck Dbottom Mpa -1.32 -1.32 -1.32 -1.196 -1.071 -1.071 -1.071 -1.071 -1.071
Gtop Mpa -1.32 -1.32 -1.32 -1.196 -1.071 -1.071 -1.071 -1.071 -1.071
Stresses Girder
At Gbottom Mpa 2.8058 2.8058 2.8058 2.3486 1.8872 1.8872 1.8872 1.8872 1.8872
STRESSES DUE TO -VE TEMPERATURE STRESSES :
Dtop Mpa -2.831 -2.831 -2.831 -2.739 -2.646 -2.646 -2.646 -2.646 -2.646
Deck Dbottom Mpa 0.6502 0.6502 0.6502 0.7612 0.8733 0.8733 0.8733 0.8733 0.8733
Gtop Mpa 0.6502 0.6502 0.6502 0.7612 0.8733 0.8733 0.8733 0.8733 0.8733
Stresses Girder
At Gbottom Mpa -3.179 -3.179 -3.179 -2.873 -2.564 -2.564 -2.564 -2.564 -2.564

EPC Contractor-M/s Krishna Constructions 170


Design ch-109+720
Design of PSC Girder

STRESSES AT DIFFERENT STAGES DUE TO PRE-STRESSING FORCES :


Load factor Superior load factor = 1.1
Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Gtop At day 14 Mpa -3.243 -3.308 -3.364 -3.985 -4.082 -4.176 -5.322 -5.943 -6.077
Girder Gbottom Mpa 10.272 10.342 10.403 13.332 18.208 18.312 19.623 20.408 20.684

Gtop 14 To day 28 Mpa -3.104 -3.166 -3.22 -3.794 -3.851 -3.939 -5.018 -5.604 -5.727
Girder Gbottom Mpa 9.8312 9.8978 9.9563 12.693 17.175 17.273 18.506 19.243 19.492

Gtop At day 28 Mpa 0.8114 0.5966 0.408 -0.542 -0.528 -0.836 -4.605 -6.601 -6.922
Girder Gbottom Mpa 9.8551 10.082 10.281 14.842 22.173 22.504 26.611 28.939 29.439

Gtop 28 To day 35 Mpa 0.7486 0.5387 0.3542 -0.573 -0.546 -0.845 -4.501 -6.428 -6.738
Girder Gbottom Mpa 9.7739 9.9946 10.188 14.639 21.73 22.047 25.964 28.163 28.64

Girder Gtop 35 To day 63 Mpa 0.7492 0.5418 0.3597 -0.549 -0.509 -0.803 -4.408 -6.32 -6.631
Gbottom Mpa 9.6184 9.8369 10.028 14.39 21.301 21.614 25.527 27.747 28.238

Girder Gtop 63 To day 64 Mpa 0.7491 0.5417 0.3597 -0.548 -0.508 -0.802 -4.405 -6.317 -6.628
Gbottom Mpa 9.6147 9.8331 10.025 14.384 21.29 21.603 25.514 27.733 28.224

Girder Gtop 64 To day 92 Mpa 0.7533 0.5473 0.3666 -0.53 -0.482 -0.773 -4.349 -6.251 -6.562
Gbottom Mpa 9.5277 9.7449 9.9351 14.245 21.051 21.362 25.263 27.486 27.983

Gtop 92 To day 36500 Mpa 0.7963 0.6113 0.4494 -0.305 -0.181 -0.436 -3.577 -5.253 -5.521
Girder Gbottom Mpa 8.3259 8.5203 8.6899 12.346 17.884 18.153 21.573 23.514 23.931

RARE LOAD COMBINATIONS :


1) Rare Combination LC-SR1 : At the time of 1st stage prestress, just after ES loss of Stage -I cables
Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop At day 14 Mpa -3.243 -3.308 -3.364 -3.985 -4.082 -4.176 -5.322 -5.943 -6.077
Girder Gbottom Mpa 10.272 10.342 10.403 13.332 18.208 18.312 19.623 20.408 20.684

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

Total Stresses (A+B)


Gtop Mpa -3.253 -3.195 -3.146 -2.681 -1.396 -1.333 -0.533 0.0126 0.2679
Girder Gbottom Mpa 10.282 10.226 10.179 12.005 15.51 15.458 14.815 14.427 14.313

Max Compressive stress = 15.51 Mpa < 24 Mpa OK


Max Tensile Stress = -3.253 Mpa >= -3.516 Mpa OK

2) Rare Combination LC-SR2 : At day 28 Just before II Stage prestressing


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop At day 0 Mpa -3.104 -3.166 -3.22 -3.794 -3.851 -3.939 -5.018 -5.604 -5.727
Girder Gbottom Mpa 9.8312 9.8978 9.9563 12.693 17.175 17.273 18.506 19.243 19.492

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

Total Stresses (A+B)

EPC Contractor-M/s Krishna Constructions 171


Design ch-109+720
Design of PSC Girder

Gtop Mpa -3.113 -3.053 -3.002 -2.49 -1.164 -1.096 -0.23 0.3518 0.6182
Girder Gbottom Mpa 9.841 9.7815 9.7317 11.366 14.477 14.419 13.698 13.263 13.121

Max Compressive stress = 14.477 Mpa < 24 Mpa OK


Max Tensile Stress = -3.113 Mpa >= -3.516 Mpa OK

3) Rare Combination LC-SR3 : At day 28 Just after II Stage prestressing after ES


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.8114 0.5966 0.408 -0.542 -0.528 -0.836 -4.605 -6.601 -6.922
Girder Gbottom Mpa 9.8551 10.082 10.281 14.842 22.173 22.504 26.611 28.939 29.439

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

Total Stresses (A+B)


Gtop Mpa 0.8019 0.7095 0.6259 0.762 2.1583 2.0058 0.1832 -0.645 -0.577
Girder Gbottom Mpa 9.8649 9.9653 10.056 13.515 19.476 19.65 21.803 22.959 23.068

Max Compressive stress = 23.068 Mpa < 24 Mpa OK


Max Tensile Stress = -0.645 Mpa >= -3.516 Mpa OK

4) Rare Combination LC-SR4 : At day 35 At the time of casting of deck slab


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.7486 0.5387 0.3542 -0.573 -0.546 -0.845 -4.501 -6.428 -6.738
Girder Gbottom Mpa 9.7739 9.9946 10.188 14.639 21.73 22.047 25.964 28.163 28.64

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder Gbottom Mpa 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086
Total Stresses (A+B +C)
Gtop Mpa 0.733 0.7175 0.7065 1.6806 4.156 4.0917 4.0404 4.3236 4.6723
Girder Gbottom Mpa 9.79 9.8101 9.8251 12.346 17.01 17.09 17.388 17.367 17.183

Max Compressive stress = 17.388 Mpa < 24 Mpa OK


Max Tensile Stress = 0.7065 Mpa >= -3.516 Mpa OK

5) Rare Combination LC-SR5 : At day 63 At the time of transfer over permanent bearings
Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.7492 0.5418 0.3597 -0.549 -0.509 -0.803 -4.408 -6.32 -6.631
Girder Gbottom Mpa 9.6184 9.8369 10.028 14.39 21.301 21.614 25.527 27.747 28.238

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

C) Stresses due to deck slab Load factor = 1

EPC Contractor-M/s Krishna Constructions 172


Design ch-109+720
Design of PSC Girder

Gtop Mpa -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder Gbottom Mpa 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to differencial shrinkage Load factor = 1
Dtop Mpa -0.182 -0.182 -0.182 -0.162 -0.122 -0.122 -0.122 -0.122 -0.122
Deck Dbottom Mpa -0.224 -0.224 -0.224 -0.205 -0.167 -0.167 -0.167 -0.167 -0.167
Gtop Mpa 0.2822 0.2822 0.2822 0.3008 0.3393 0.3393 0.3393 0.3393 0.3393
Girder Gbottom Mpa -0.151 -0.151 -0.151 -0.148 -0.131 -0.131 -0.131 -0.131 -0.131
Total Stresses (A+B +C+D+E)
Dtop Mpa -0.182 -0.182 -0.182 -0.162 -0.122 -0.122 -0.122 -0.122 -0.122
Deck Dbottom Mpa -0.224 -0.224 -0.224 -0.205 -0.167 -0.167 -0.167 -0.167 -0.167
Gtop Mpa 1.0159 1.0028 0.9942 2.0057 4.5316 4.4726 4.4727 4.7708 5.1185
Girder Gbottom Mpa 9.4831 9.5011 9.5138 11.948 16.45 16.527 16.82 16.82 16.65

Max Compressive stress = 16.82 Mpa < 24 Mpa OK


Max Tensile Stress = 0.9942 Mpa >= -3.516 Mpa OK

6) Rare Combination LC-SR6 : At day 64 At the time of placing of SIDL


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.7491 0.5417 0.3597 -0.548 -0.508 -0.802 -4.405 -6.317 -6.628
Girder Gbottom Mpa 9.6147 9.8331 10.025 14.384 21.29 21.603 25.514 27.733 28.224

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder Gbottom Mpa 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.1) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.2) Stresses due to placement of SurfacingLoad factor = 1
Dtop Mpa 0 0.0107 0.0201 0.1063 0.1964 0.2083 0.3559 0.4423 0.4729
Deck Dbottom Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Gtop Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Girder Gbottom Mpa 0 -0.015 -0.028 -0.173 -0.375 -0.397 -0.679 -0.843 -0.902

F) Stresses due to Differential shrinkage Load factor = 1


Dtop Mpa -0.182 -0.182 -0.182 -0.162 -0.122 -0.122 -0.122 -0.122 -0.122
Deck Dbottom Mpa -0.224 -0.224 -0.224 -0.205 -0.167 -0.167 -0.167 -0.167 -0.167
Gtop Mpa 0.2821 0.2821 0.2821 0.3007 0.3392 0.3392 0.3392 0.3392 0.3392
Girder Gbottom Mpa -0.151 -0.151 -0.151 -0.148 -0.131 -0.131 -0.131 -0.131 -0.131
G) Stresses due to wind Load factor = 0.6
Dtop Mpa 0 0.0063 0.0119 0.0628 0.1161 0.1231 0.2102 0.2613 0.2794
Deck Dbottom Mpa 0 0.005 0.0094 0.0484 0.0866 0.0918 0.1569 0.195 0.2085

EPC Contractor-M/s Krishna Constructions 173


Design ch-109+720
Design of PSC Girder

Gtop Mpa 0 0.005 0.0094 0.0484 0.0866 0.0918 0.1569 0.195 0.2085
Girder Gbottom Mpa 0 -0.009 -0.017 -0.102 -0.221 -0.235 -0.401 -0.498 -0.533
Total Stresses (A+B +C+D+E+F)
Dtop Mpa -0.182 -0.172 -0.162 -0.056 0.0746 0.0865 0.234 0.3205 0.3511
Deck Dbottom Mpa -0.224 -0.215 -0.208 -0.123 -0.02 -0.011 0.0988 0.1633 0.1861
Gtop Mpa 1.0156 1.0111 1.0101 2.088 4.679 4.629 4.7408 5.1042 5.4747
Girder Gbottom Mpa 9.4795 9.4824 9.4817 11.769 16.064 16.118 16.129 15.963 15.735
Total Stresses (A+B +C+D+E+F+G) wind downward
Dtop Mpa -0.182 -0.165 -0.15 0.0067 0.1907 0.2096 0.4443 0.5818 0.6304
Deck Dbottom Mpa -0.224 -0.21 -0.199 -0.075 0.0664 0.0805 0.2557 0.3583 0.3946
Gtop Mpa 1.0156 1.0161 1.0195 2.1364 4.7656 4.7209 4.8977 5.2992 5.6832
Girder Gbottom Mpa 9.4795 9.4735 9.465 11.667 15.843 15.883 15.728 15.465 15.202
Total Stresses (A+B +C+D+E+F+G) wind upward
Dtop Mpa -0.182 -0.178 -0.174 -0.119 -0.041 -0.037 0.0238 0.0592 0.0717
Deck Dbottom Mpa -0.224 -0.22 -0.217 -0.172 -0.107 -0.103 -0.058 -0.032 -0.022
Gtop Mpa 1.0156 1.0061 1.0007 2.0396 4.5924 4.5372 4.5839 4.9092 5.2663
Girder Gbottom Mpa 9.4795 9.4913 9.4984 11.871 16.285 16.353 16.53 16.462 16.267

Max Compressive stress = 16.129 Mpa < 24 Mpa OK


Max Tensile Stress = 1.0101 Mpa >= -3.516 Mpa OK

Max Compressive stress (wind downward)= 15.883 Mpa < 24 Mpa OK


Max Tensile Stress (wind downward) = 1.0156 Mpa >= -3.516 Mpa OK

Max Compressive stress (wind upward) = 16.53 Mpa < 24 Mpa OK


Max Tensile Stress (wind upward) = 1.0007 Mpa >= -3.516 Mpa OK

7) Rare Combination LC-SR7 : At day 92 Structure open to LL


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.7533 0.5473 0.3666 -0.53 -0.482 -0.773 -4.349 -6.251 -6.562
Girder Gbottom Mpa 9.5277 9.7449 9.9351 14.245 21.051 21.362 25.263 27.486 27.983

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder Gbottom Mpa 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0107 0.0201 0.1063 0.1964 0.2083 0.3559 0.4423 0.4729
Deck Dbottom Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Gtop Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Girder Gbottom Mpa 0 -0.015 -0.028 -0.173 -0.375 -0.397 -0.679 -0.843 -0.902
F) Stresses due to Live load (Without SV) Load factor = 1
Dtop Mpa 0 0.1058 0.1761 0.7787 1.3087 1.3811 1.8455 2.319 2.3818
Deck Dbottom Mpa 0 0.0836 0.1392 0.5999 0.9766 1.0306 1.3772 1.7306 1.7774
Gtop Mpa 0 0.0836 0.1392 0.5999 0.9766 1.0306 1.3772 1.7306 1.7774
Girder Gbottom Mpa 0 -0.149 -0.247 -1.269 -2.495 -2.633 -3.519 -4.422 -4.541

EPC Contractor-M/s Krishna Constructions 174


Design ch-109+720
Design of PSC Girder

F.1) Stresses due to Live load (With SV) Load factor = 1


Dtop Mpa 0 0.0466 0.0949 0.5406 1.0189 1.0869 1.9221 2.5089 2.5948
Deck Dbottom Mpa 0 0.0368 0.075 0.4165 0.7604 0.8111 1.4343 1.8722 1.9363
Gtop Mpa 0 0.0368 0.075 0.4165 0.7604 0.8111 1.4343 1.8722 1.9363
Girder Gbottom Mpa 0 -0.065 -0.133 -0.881 -1.943 -2.073 -3.665 -4.784 -4.948
G) Stresses due to differential shrinkage Load factor = 1
Dtop Mpa -0.173 -0.173 -0.173 -0.154 -0.116 -0.116 -0.116 -0.116 -0.116
Deck Dbottom Mpa -0.213 -0.213 -0.213 -0.195 -0.158 -0.158 -0.158 -0.158 -0.158
Gtop Mpa 0.2681 0.2681 0.2681 0.2857 0.3223 0.3223 0.3223 0.3223 0.3223
Girder Gbottom Mpa -0.144 -0.144 -0.144 -0.141 -0.124 -0.124 -0.124 -0.124 -0.124
G) Stresses due to wind Load factor = 0.6
Dtop Mpa 0 0.0063 0.0119 0.0628 0.1161 0.1231 0.2102 0.2613 0.2794
Deck Dbottom Mpa 0 0.005 0.0094 0.0484 0.0866 0.0918 0.1569 0.195 0.2085
Gtop Mpa 0 0.005 0.0094 0.0484 0.0866 0.0918 0.1569 0.195 0.2085
Girder Gbottom Mpa 0 -0.009 -0.017 -0.102 -0.221 -0.235 -0.401 -0.498 -0.533
Total Stresses (A+B +C+D+E+F+G) (Without SV Loading)
Dtop Mpa -0.173 -0.057 0.023 0.7307 1.3894 1.4736 2.0856 2.6456 2.7389
Deck Dbottom Mpa -0.213 -0.121 -0.058 0.4867 0.9647 1.0276 1.4843 1.9021 1.9718
Gtop Mpa 1.0058 1.0863 1.1421 2.691 5.665 5.6716 6.1574 6.8837 7.3007
Girder Gbottom Mpa 9.4001 9.2532 9.1526 10.368 13.337 13.251 12.365 11.301 10.958
Total Stresses (A+B +C+D+E+F+G) (With SV Loading)
Dtop Mpa -0.173 -0.116 -0.058 0.4926 1.0996 1.1795 2.1622 2.8354 2.9519
Deck Dbottom Mpa -0.213 -0.167 -0.122 0.3032 0.7485 0.8081 1.5414 2.0438 2.1307
Gtop Mpa 1.0058 1.0396 1.078 2.5076 5.4487 5.4521 6.2146 7.0254 7.4597
Girder Gbottom Mpa 9.4001 9.3363 9.2666 10.757 13.889 13.812 12.219 10.939 10.552
Total Stresses (A+B +C+D+E+F+G) wind downward
Dtop Mpa -0.173 -0.051 0.0348 0.7935 1.5054 1.5967 2.2958 2.9069 3.0183
Deck Dbottom Mpa -0.213 -0.116 -0.048 0.5351 1.0513 1.1194 1.6411 2.0971 2.1803
Gtop Mpa 1.0058 1.0913 1.1515 2.7394 5.7516 5.7635 6.3143 7.0787 7.5092
Girder Gbottom Mpa 9.4001 9.2443 9.1359 10.266 13.115 13.016 11.964 10.802 10.426
Total Stresses (A+B +C+D+E+F+G) wind upward
Dtop Mpa -0.173 -0.063 0.0111 0.6679 1.2733 1.3506 1.8754 2.3843 2.4595
Deck Dbottom Mpa -0.213 -0.126 -0.067 0.4383 0.8781 0.9357 1.3274 1.7071 1.7633
Gtop Mpa 1.0058 1.0814 1.1327 2.6427 5.5784 5.5798 6.0005 6.6887 7.0922
Girder Gbottom Mpa 9.4001 9.262 9.1693 10.471 13.558 13.486 12.766 11.799 11.491
Max Compressive stress = 13.889 Mpa < 24 Mpa OK
Max Tensile Stress = 1.0058 Mpa >= -3.516 Mpa OK

Max Compressive stress (wind downward)= 13.115 Mpa < 24 Mpa OK


Max Tensile Stress (wind downward) = 1.0058 Mpa >= -3.516 Mpa OK
Max Compressive stress (wind upward) = 13.558 Mpa < 24 Mpa OK
Max Tensile Stress (wind upward) = 1.0058 Mpa >= -3.516 Mpa OK

7.1) Rare Combination LC-SR7.1 : At day 92 Structure open to LL + temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.7533 0.5473 0.3666 -0.53 -0.482 -0.773 -4.349 -6.251 -6.562
Girder Gbottom Mpa 9.5277 9.7449 9.9351 14.245 21.051 21.362 25.263 27.486 27.983

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder Gbottom Mpa 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086

D) Stresses due to transfer over permanentLoad


bearings
factor = 1

EPC Contractor-M/s Krishna Constructions 175


Design ch-109+720
Design of PSC Girder

Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0107 0.0201 0.1063 0.1964 0.2083 0.3559 0.4423 0.4729
Deck Dbottom Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Gtop Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Girder Gbottom Mpa 0 -0.015 -0.028 -0.173 -0.375 -0.397 -0.679 -0.843 -0.902
F) Stresses due to Live load (Without SV) Load factor = 1
Dtop Mpa 0 0.1058 0.1761 0.7787 1.3087 1.3811 1.8455 2.319 2.3818
Deck Dbottom Mpa 0 0.0836 0.1392 0.5999 0.9766 1.0306 1.3772 1.7306 1.7774
Gtop Mpa 0 0.0836 0.1392 0.5999 0.9766 1.0306 1.3772 1.7306 1.7774
Girder Gbottom Mpa 0 -0.149 -0.247 -1.269 -2.495 -2.633 -3.519 -4.422 -4.541
F.1) Stresses due to Live load (With SV) Load factor = 1
Dtop Mpa 0 0.0466 0.0949 0.5406 1.0189 1.0869 1.9221 2.5089 2.5948
Deck Dbottom Mpa 0 0.0368 0.075 0.4165 0.7604 0.8111 1.4343 1.8722 1.9363
Gtop Mpa 0 0.0368 0.075 0.4165 0.7604 0.8111 1.4343 1.8722 1.9363
Girder Gbottom Mpa 0 -0.065 -0.133 -0.881 -1.943 -2.073 -3.665 -4.784 -4.948
G) Stresses due to differential shrinkage Load factor = 1
Dtop Mpa -0.173 -0.173 -0.173 -0.154 -0.116 -0.116 -0.116 -0.116 -0.116
Deck Dbottom Mpa -0.213 -0.213 -0.213 -0.195 -0.158 -0.158 -0.158 -0.158 -0.158
Gtop Mpa 0.2681 0.2681 0.2681 0.2857 0.3223 0.3223 0.3223 0.3223 0.3223
Girder Gbottom Mpa -0.144 -0.144 -0.144 -0.141 -0.124 -0.124 -0.124 -0.124 -0.124

H) +ve temperature stresses Load factor = 0.6


Dtop Mpa 2.712 2.712 2.712 2.8197 2.9285 2.9285 2.9285 2.9285 2.9285
Deck Dbottom Mpa -0.792 -0.792 -0.792 -0.718 -0.643 -0.643 -0.643 -0.643 -0.643
Gtop Mpa -0.792 -0.792 -0.792 -0.718 -0.643 -0.643 -0.643 -0.643 -0.643
Girder Gbottom Mpa 1.6835 1.6835 1.6835 1.4091 1.1323 1.1323 1.1323 1.1323 1.1323
Total Stresses (A+B +C+D+E+F+G+H) (Without SV)
Dtop Mpa 2.5387 2.6552 2.7349 3.5504 4.3178 4.4021 5.0141 5.5741 5.6674
Deck Dbottom Mpa -1.005 -0.913 -0.85 -0.231 0.322 0.3849 0.8415 1.2594 1.329
Gtop Mpa 0.2139 0.2945 0.3502 1.9734 5.0222 5.0289 5.5147 6.241 6.658
Girder Gbottom Mpa 11.084 10.937 10.836 11.778 14.469 14.383 13.498 12.433 12.091
Total Stresses (A+B +C+D+E+F+G+H) (With SV Loading)
Dtop Mpa -0.173 -0.116 -0.058 0.4926 1.0996 1.1795 2.1622 2.8354 2.9519
Deck Dbottom Mpa -0.213 -0.167 -0.122 0.3032 0.7485 0.8081 1.5414 2.0438 2.1307
Gtop Mpa 1.0058 1.0396 1.078 2.5076 5.4487 5.4521 6.2146 7.0254 7.4597
Girder Gbottom Mpa 9.4001 9.3363 9.2666 10.757 13.889 13.812 12.219 10.939 10.552

Max Compressive stress = 14.469 Mpa < 24 Mpa OK


Max Tensile Stress = 0.2139 Mpa >= -3.516 Mpa OK

7.2) Rare Combination LC-SR7.2 : At day 92 Structure open to LL - temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.7533 0.5473 0.3666 -0.53 -0.482 -0.773 -4.349 -6.251 -6.562
Girder Gbottom Mpa 9.5277 9.7449 9.9351 14.245 21.051 21.362 25.263 27.486 27.983

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

EPC Contractor-M/s Krishna Constructions 176


Design ch-109+720
Design of PSC Girder

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder Gbottom Mpa 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0107 0.0201 0.1063 0.1964 0.2083 0.3559 0.4423 0.4729
Deck Dbottom Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Gtop Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Girder Gbottom Mpa 0 -0.015 -0.028 -0.173 -0.375 -0.397 -0.679 -0.843 -0.902
F) Stresses due to Live load (Without SV) Load factor = 1
Dtop Mpa 0 0.1058 0.1761 0.7787 1.3087 1.3811 1.8455 2.319 2.3818
Deck Dbottom Mpa 0 0.0836 0.1392 0.5999 0.9766 1.0306 1.3772 1.7306 1.7774
Gtop Mpa 0 0.0836 0.1392 0.5999 0.9766 1.0306 1.3772 1.7306 1.7774
Girder Gbottom Mpa 0 -0.149 -0.247 -1.269 -2.495 -2.633 -3.519 -4.422 -4.541
F.1) Stresses due to Live load (With SV) Load factor = 1
Dtop Mpa 0 0.0466 0.0949 0.5406 1.0189 1.0869 1.9221 2.5089 2.5948
Deck Dbottom Mpa 0 0.0368 0.075 0.4165 0.7604 0.8111 1.4343 1.8722 1.9363
Gtop Mpa 0 0.0368 0.075 0.4165 0.7604 0.8111 1.4343 1.8722 1.9363
Girder Gbottom Mpa 0 -0.065 -0.133 -0.881 -1.943 -2.073 -3.665 -4.784 -4.948

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.173 -0.173 -0.173 -0.154 -0.116 -0.116 -0.116 -0.116 -0.116
Deck Dbottom Mpa -0.213 -0.213 -0.213 -0.195 -0.158 -0.158 -0.158 -0.158 -0.158
Gtop Mpa 0.2681 0.2681 0.2681 0.2857 0.3223 0.3223 0.3223 0.3223 0.3223
Girder Gbottom Mpa -0.144 -0.144 -0.144 -0.141 -0.124 -0.124 -0.124 -0.124 -0.124
H) -ve temperature stresses Load factor = 0.6
Dtop Mpa -1.699 -1.699 -1.699 -1.643 -1.588 -1.588 -1.588 -1.588 -1.588
Deck Dbottom Mpa 0.3901 0.3901 0.3901 0.4567 0.524 0.524 0.524 0.524 0.524
Gtop Mpa 0.3901 0.3901 0.3901 0.4567 0.524 0.524 0.524 0.524 0.524
Girder Gbottom Mpa -1.907 -1.907 -1.907 -1.724 -1.538 -1.538 -1.538 -1.538 -1.538
Total Stresses (A+B +C+D+E+F+G+H) (Without SV)
Dtop Mpa -1.872 -1.755 -1.676 -0.913 -0.198 -0.114 0.4979 1.0579 1.1512
Deck Dbottom Mpa 0.1774 0.2694 0.3325 0.9434 1.4887 1.5516 2.0082 2.4261 2.4957
Gtop Mpa 1.3959 1.4764 1.5322 3.1478 6.1889 6.1956 6.6814 7.4077 7.8247
Girder Gbottom Mpa 7.4927 7.3459 7.2453 8.6449 11.798 11.713 10.827 9.7623 9.4201
Total Stresses (A+B +C+D+E+F+G+H) (With SV Loading)
Dtop Mpa -0.173 -0.116 -0.058 0.4926 1.0996 1.1795 2.1622 2.8354 2.9519
Deck Dbottom Mpa -0.213 -0.167 -0.122 0.3032 0.7485 0.8081 1.5414 2.0438 2.1307
Gtop Mpa 1.0058 1.0396 1.078 2.5076 5.4487 5.4521 6.2146 7.0254 7.4597
Girder Gbottom Mpa 9.4001 9.3363 9.2666 10.757 13.889 13.812 12.219 10.939 10.552

Max Compressive stress = 13.889 Mpa < 24 Mpa OK


Max Tensile Stress = 1.0058 Mpa >= -3.516 Mpa OK

7.3) Rare Combination LC-SR7.3 : At day 92 Structure open to LL + temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1

EPC Contractor-M/s Krishna Constructions 177


Design ch-109+720
Design of PSC Girder

Gtop Mpa 0.7533 0.5473 0.3666 -0.53 -0.482 -0.773 -4.349 -6.251 -6.562
Girder Gbottom Mpa 9.5277 9.7449 9.9351 14.245 21.051 21.362 25.263 27.486 27.983

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder Gbottom Mpa 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0107 0.0201 0.1063 0.1964 0.2083 0.3559 0.4423 0.4729
Deck Dbottom Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Gtop Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Girder Gbottom Mpa 0 -0.015 -0.028 -0.173 -0.375 -0.397 -0.679 -0.843 -0.902
F) Stresses due to Live load (Without SV) Load factor = 0.75
Dtop Mpa 0 0.0794 0.1321 0.584 0.9815 1.0358 1.3841 1.7393 1.7863
Deck Dbottom Mpa 0 0.0627 0.1044 0.4499 0.7324 0.773 1.0329 1.2979 1.333
Gtop Mpa 0 0.0627 0.1044 0.4499 0.7324 0.773 1.0329 1.2979 1.333
Girder Gbottom Mpa 0 -0.111 -0.185 -0.952 -1.871 -1.975 -2.639 -3.316 -3.406
F.1) Stresses due to Live load (With SV) Load factor = 0.75
Dtop Mpa 0 0.035 0.0712 0.4054 0.7642 0.8152 1.4416 1.8817 1.9461
Deck Dbottom Mpa 0 0.0276 0.0563 0.3123 0.5703 0.6083 1.0757 1.4042 1.4522
Gtop Mpa 0 0.0276 0.0563 0.3123 0.5703 0.6083 1.0757 1.4042 1.4522
Girder Gbottom Mpa 0 -0.049 -0.1 -0.661 -1.457 -1.554 -2.749 -3.588 -3.711

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.173 -0.173 -0.173 -0.154 -0.116 -0.116 -0.116 -0.116 -0.116
Deck Dbottom Mpa -0.213 -0.213 -0.213 -0.195 -0.158 -0.158 -0.158 -0.158 -0.158
Gtop Mpa 0.2681 0.2681 0.2681 0.2857 0.3223 0.3223 0.3223 0.3223 0.3223
Girder Gbottom Mpa -0.144 -0.144 -0.144 -0.141 -0.124 -0.124 -0.124 -0.124 -0.124
H) +ve temperature stresses Load factor = 1
Dtop Mpa 4.52 4.52 4.52 4.6996 4.8808 4.8808 4.8808 4.8808 4.8808
Deck Dbottom Mpa -1.32 -1.32 -1.32 -1.196 -1.071 -1.071 -1.071 -1.071 -1.071
Gtop Mpa -1.32 -1.32 -1.32 -1.196 -1.071 -1.071 -1.071 -1.071 -1.071
Girder Gbottom Mpa 2.8058 2.8058 2.8058 2.3486 1.8872 1.8872 1.8872 1.8872 1.8872
Total Stresses (A+B +C+D+E+F+G+H) (Without SV)
Dtop Mpa 4.3466 4.4367 4.4989 5.2356 5.943 6.0092 6.505 6.9466 7.0242
Deck Dbottom Mpa -1.533 -1.461 -1.412 -0.859 -0.351 -0.301 0.0687 0.3983 0.4562
Gtop Mpa -0.314 -0.254 -0.212 1.345 4.3496 4.3427 4.7419 5.3798 5.7852
Girder Gbottom Mpa 12.206 12.096 12.02 13.034 15.848 15.796 15.132 14.293 13.981
Total Stresses (A+B +C+D+E+F+G+H) (With SV Loading)
Dtop Mpa -0.173 -0.128 -0.082 0.3574 0.8449 0.9078 1.6816 2.2082 2.3032
Deck Dbottom Mpa -0.213 -0.177 -0.141 0.1991 0.5584 0.6053 1.1828 1.5758 1.6466
Gtop Mpa 1.0058 1.0304 1.0592 2.4035 5.2586 5.2493 5.856 6.5573 6.9756
Girder Gbottom Mpa 9.4001 9.3526 9.2999 10.977 14.375 14.33 13.135 12.135 11.789

Max Compressive stress = 15.848 Mpa < 24 Mpa OK


Max Tensile Stress = -0.314 Mpa >= -3.516 Mpa OK

EPC Contractor-M/s Krishna Constructions 178


Design ch-109+720
Design of PSC Girder

7.4) Rare Combination LC-SR7.4 : At day 92 Structure open to LL - temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.7533 0.5473 0.3666 -0.53 -0.482 -0.773 -4.349 -6.251 -6.562
Girder Gbottom Mpa 9.5277 9.7449 9.9351 14.245 21.051 21.362 25.263 27.486 27.983

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder Gbottom Mpa 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0107 0.0201 0.1063 0.1964 0.2083 0.3559 0.4423 0.4729
Deck Dbottom Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Gtop Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Girder Gbottom Mpa 0 -0.015 -0.028 -0.173 -0.375 -0.397 -0.679 -0.843 -0.902
F) Stresses due to Live load (Without SV) Load factor = 0.75
Dtop Mpa 0 0.0794 0.1321 0.584 0.9815 1.0358 1.3841 1.7393 1.7863
Deck Dbottom Mpa 0 0.0627 0.1044 0.4499 0.7324 0.773 1.0329 1.2979 1.333
Gtop Mpa 0 0.0627 0.1044 0.4499 0.7324 0.773 1.0329 1.2979 1.333
Girder Gbottom Mpa 0 -0.111 -0.185 -0.952 -1.871 -1.975 -2.639 -3.316 -3.406
F.1) Stresses due to Live load (With SV) Load factor = 0.75
Dtop Mpa 0 0.035 0.0712 0.4054 0.7642 0.8152 1.4416 1.8817 1.9461
Deck Dbottom Mpa 0 0.0276 0.0563 0.3123 0.5703 0.6083 1.0757 1.4042 1.4522
Gtop Mpa 0 0.0276 0.0563 0.3123 0.5703 0.6083 1.0757 1.4042 1.4522
Girder Gbottom Mpa 0 -0.049 -0.1 -0.661 -1.457 -1.554 -2.749 -3.588 -3.711

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.173 -0.173 -0.173 -0.154 -0.116 -0.116 -0.116 -0.116 -0.116
Deck Dbottom Mpa -0.213 -0.213 -0.213 -0.195 -0.158 -0.158 -0.158 -0.158 -0.158
Gtop Mpa 0.2681 0.2681 0.2681 0.2857 0.3223 0.3223 0.3223 0.3223 0.3223
Girder Gbottom Mpa -0.144 -0.144 -0.144 -0.141 -0.124 -0.124 -0.124 -0.124 -0.124
H) -ve temperature stresses Load factor = 1
Dtop Mpa -2.831 -2.831 -2.831 -2.739 -2.646 -2.646 -2.646 -2.646 -2.646
Deck Dbottom Mpa 0.6502 0.6502 0.6502 0.7612 0.8733 0.8733 0.8733 0.8733 0.8733
Gtop Mpa 0.6502 0.6502 0.6502 0.7612 0.8733 0.8733 0.8733 0.8733 0.8733
Girder Gbottom Mpa -3.179 -3.179 -3.179 -2.873 -2.564 -2.564 -2.564 -2.564 -2.564
Total Stresses (A+B +C+D+E+F+G+H) (Without SV)
Dtop Mpa -3.004 -2.914 -2.852 -2.203 -1.584 -1.518 -1.022 -0.58 -0.503
Deck Dbottom Mpa 0.4375 0.5086 0.5577 1.0979 1.5938 1.6432 2.0132 2.3428 2.4007
Gtop Mpa 1.656 1.7156 1.7575 3.3023 6.2941 6.2872 6.6864 7.3243 7.7297
Girder Gbottom Mpa 6.2212 6.1115 6.0356 7.8131 11.397 11.345 10.681 9.8422 9.5299
Total Stresses (A+B +C+D+E+F+G+H) (With SV Loading)
Dtop Mpa -0.173 -0.128 -0.082 0.3574 0.8449 0.9078 1.6816 2.2082 2.3032
Deck Dbottom Mpa -0.213 -0.177 -0.141 0.1991 0.5584 0.6053 1.1828 1.5758 1.6466
Gtop Mpa 1.0058 1.0304 1.0592 2.4035 5.2586 5.2493 5.856 6.5573 6.9756
Girder

EPC Contractor-M/s Krishna Constructions 179


Design ch-109+720
Design of PSC Girder

Girder Gbottom Mpa 9.4001 9.3526 9.2999 10.977 14.375 14.33 13.135 12.135 11.789

Max Compressive stress = 14.375 Mpa < 24 Mpa OK


Max Tensile Stress = 1.0058 Mpa >= -3.516 Mpa OK

8) Rare Combination LC-SR8 : At day 36500


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.7963 0.6113 0.4494 -0.305 -0.181 -0.436 -3.577 -5.253 -5.521
Girder Gbottom Mpa 8.3259 8.5203 8.6899 12.346 17.884 18.153 21.573 23.514 23.931

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder Gbottom Mpa 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.1) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.2) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0107 0.0201 0.1063 0.1964 0.2083 0.3559 0.4423 0.4729
Deck Dbottom Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Gtop Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Girder Gbottom Mpa 0 -0.015 -0.028 -0.173 -0.375 -0.397 -0.679 -0.843 -0.902
F) Stresses due to Live load (Without SV) Load factor = 1
Dtop Mpa 0 0.1058 0.1761 0.7787 1.3087 1.3811 1.8455 2.319 2.3818
Deck Dbottom Mpa 0 0.0836 0.1392 0.5999 0.9766 1.0306 1.3772 1.7306 1.7774
Gtop Mpa 0 0.0836 0.1392 0.5999 0.9766 1.0306 1.3772 1.7306 1.7774
Girder Gbottom Mpa 0 -0.149 -0.247 -1.269 -2.495 -2.633 -3.519 -4.422 -4.541
F.1) Stresses due to Live load (With SV) Load factor = 1
Dtop Mpa 0 0.0466 0.0949 0.5406 1.0189 1.0869 1.9221 2.5089 2.5948
Deck Dbottom Mpa 0 0.0368 0.075 0.4165 0.7604 0.8111 1.4343 1.8722 1.9363
Gtop Mpa 0 0.0368 0.075 0.4165 0.7604 0.8111 1.4343 1.8722 1.9363
Girder Gbottom Mpa 0 -0.065 -0.133 -0.881 -1.943 -2.073 -3.665 -4.784 -4.948

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.713 -0.713 -0.713 -0.635 -0.477 -0.477 -0.477 -0.477 -0.477
Deck Dbottom Mpa -0.875 -0.875 -0.875 -0.803 -0.652 -0.652 -0.652 -0.652 -0.652
Gtop Mpa 1.1035 1.1035 1.1035 1.1759 1.3266 1.3266 1.3266 1.3266 1.3266
Girder Gbottom Mpa -0.592 -0.592 -0.592 -0.58 -0.511 -0.511 -0.511 -0.511 -0.511
Total Stresses (A+B +C+D+E+F+G+H) (Without SV)
Dtop Mpa -0.713 -0.597 -0.517 0.25 1.0286 1.1129 1.7248 2.2848 2.3781
Deck Dbottom Mpa -0.875 -0.783 -0.72 -0.121 0.4709 0.5338 0.9904 1.4083 1.478
Gtop Mpa 1.8841 1.9857 2.0603 3.8061 6.9705 7.0135 7.9333 8.8859 9.3458
Girder Gbottom Mpa 7.7501 7.5806 7.4594 8.0299 9.7819 9.6546 8.2887 6.9425 6.5202
Total Stresses (A+B +C+D+E+F+G+H) (With SV Loading)
Dtop Mpa 0 0.0573 0.1151 0.6469 1.2154 1.2953 2.2779 2.9512 3.0677
Deck Dbottom Mpa 0 0.0453 0.0909 0.4983 0.907 0.9666 1.6999 2.2023 2.2892

EPC Contractor-M/s Krishna Constructions 180


Design ch-109+720
Design of PSC Girder

Gtop Mpa 0.7807 0.8354 0.8926 2.4467 5.4277 5.4673 6.6638 7.7009 8.1782
Girder Gbottom Mpa 8.342 8.2555 8.1652 8.9983 10.845 10.726 8.6537 7.0915 6.625

Max Compressive stress = 10.845 Mpa < 24 Mpa OK


Max Tensile Stress = 0.7807 Mpa >= -3.516 Mpa OK

8.1) Rare Combination LC-SR8.1 : At day 36500 + temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.7963 0.6113 0.4494 -0.305 -0.181 -0.436 -3.577 -5.253 -5.521
Girder Gbottom Mpa 8.3259 8.5203 8.6899 12.346 17.884 18.153 21.573 23.514 23.931

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder Gbottom Mpa 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.1) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.2) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0107 0.0201 0.1063 0.1964 0.2083 0.3559 0.4423 0.4729
Deck Dbottom Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Gtop Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Girder Gbottom Mpa 0 -0.015 -0.028 -0.173 -0.375 -0.397 -0.679 -0.843 -0.902
F) Stresses due to Live load (Without SV) Load factor = 1
Dtop Mpa 0 0.1058 0.1761 0.7787 1.3087 1.3811 1.8455 2.319 2.3818
Deck Dbottom Mpa 0 0.0836 0.1392 0.5999 0.9766 1.0306 1.3772 1.7306 1.7774
Gtop Mpa 0 0.0836 0.1392 0.5999 0.9766 1.0306 1.3772 1.7306 1.7774
Girder Gbottom Mpa 0 -0.149 -0.247 -1.269 -2.495 -2.633 -3.519 -4.422 -4.541
F.1) Stresses due to Live load (With SV) Load factor = 1
Dtop Mpa 0 0.0466 0.0949 0.5406 1.0189 1.0869 1.9221 2.5089 2.5948
Deck Dbottom Mpa 0 0.0368 0.075 0.4165 0.7604 0.8111 1.4343 1.8722 1.9363
Gtop Mpa 0 0.0368 0.075 0.4165 0.7604 0.8111 1.4343 1.8722 1.9363
Girder Gbottom Mpa 0 -0.065 -0.133 -0.881 -1.943 -2.073 -3.665 -4.784 -4.948

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.713 -0.713 -0.713 -0.635 -0.477 -0.477 -0.477 -0.477 -0.477
Deck Dbottom Mpa -0.875 -0.875 -0.875 -0.803 -0.652 -0.652 -0.652 -0.652 -0.652
Gtop Mpa 1.1035 1.1035 1.1035 1.1759 1.3266 1.3266 1.3266 1.3266 1.3266
Girder Gbottom Mpa -0.592 -0.592 -0.592 -0.58 -0.511 -0.511 -0.511 -0.511 -0.511

H) +ve temperature stresses Load factor = 0.6


Dtop Mpa 2.712 2.712 2.712 2.8197 2.9285 2.9285 2.9285 2.9285 2.9285
Deck Dbottom Mpa -0.792 -0.792 -0.792 -0.718 -0.643 -0.643 -0.643 -0.643 -0.643
Gtop Mpa -0.792 -0.792 -0.792 -0.718 -0.643 -0.643 -0.643 -0.643 -0.643
Girder Gbottom Mpa 1.6835 1.6835 1.6835 1.4091 1.1323 1.1323 1.1323 1.1323 1.1323
Total Stresses (A+B +C+D+E+F+G+H) (Without SV)

EPC Contractor-M/s Krishna Constructions 181


Design ch-109+720
Design of PSC Girder

Dtop Mpa 1.9987 2.1152 2.1949 3.0697 3.9571 4.0414 4.6533 5.2133 5.3066
Deck Dbottom Mpa -1.667 -1.575 -1.512 -0.839 -0.172 -0.109 0.3477 0.7656 0.8352
Gtop Mpa 1.0923 1.1938 1.2684 3.0884 6.3278 6.3707 7.2906 8.2432 8.7031
Girder Gbottom Mpa 9.4336 9.264 9.1428 9.439 10.914 10.787 9.421 8.0748 7.6525
Total Stresses (A+B +C+D+E+F+G+H) (With SV Loading)
Dtop Mpa -0.713 -0.656 -0.598 0.0119 0.7389 0.8188 1.8014 2.4747 2.5911
Deck Dbottom Mpa -0.875 -0.83 -0.785 -0.305 0.2547 0.3143 1.0476 1.55 1.6369
Gtop Mpa 1.8841 1.9389 1.9961 3.6226 6.7543 6.794 7.9904 9.0276 9.5048
Girder Gbottom Mpa 7.7501 7.6637 7.5733 8.4181 10.334 10.215 8.1427 6.5805 6.114

Max Compressive stress = 10.914 Mpa < 24 Mpa OK


Max Tensile Stress = 1.0923 Mpa >= -3.516 Mpa OK

8.2) Rare Combination LC-SR8.2 : At day 36500 - temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.7963 0.6113 0.4494 -0.305 -0.181 -0.436 -3.577 -5.253 -5.521
Girder Gbottom Mpa 8.3259 8.5203 8.6899 12.346 17.884 18.153 21.573 23.514 23.931

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder Gbottom Mpa 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.1) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.2) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0107 0.0201 0.1063 0.1964 0.2083 0.3559 0.4423 0.4729
Deck Dbottom Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Gtop Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Girder Gbottom Mpa 0 -0.015 -0.028 -0.173 -0.375 -0.397 -0.679 -0.843 -0.902
F) Stresses due to Live load (Without SV) Load factor = 1
Dtop Mpa 0 0.1058 0.1761 0.7787 1.3087 1.3811 1.8455 2.319 2.3818
Deck Dbottom Mpa 0 0.0836 0.1392 0.5999 0.9766 1.0306 1.3772 1.7306 1.7774
Gtop Mpa 0 0.0836 0.1392 0.5999 0.9766 1.0306 1.3772 1.7306 1.7774
Girder Gbottom Mpa 0 -0.149 -0.247 -1.269 -2.495 -2.633 -3.519 -4.422 -4.541
F.1) Stresses due to Live load (With SV) Load factor = 1
Dtop Mpa 0 0.0466 0.0949 0.5406 1.0189 1.0869 1.9221 2.5089 2.5948
Deck Dbottom Mpa 0 0.0368 0.075 0.4165 0.7604 0.8111 1.4343 1.8722 1.9363
Gtop Mpa 0 0.0368 0.075 0.4165 0.7604 0.8111 1.4343 1.8722 1.9363
Girder Gbottom Mpa 0 -0.065 -0.133 -0.881 -1.943 -2.073 -3.665 -4.784 -4.948

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.713 -0.713 -0.713 -0.635 -0.477 -0.477 -0.477 -0.477 -0.477
Deck Dbottom Mpa -0.875 -0.875 -0.875 -0.803 -0.652 -0.652 -0.652 -0.652 -0.652
Gtop Mpa 1.1035 1.1035 1.1035 1.1759 1.3266 1.3266 1.3266 1.3266 1.3266
Girder Gbottom Mpa -0.592 -0.592 -0.592 -0.58 -0.511 -0.511 -0.511 -0.511 -0.511

EPC Contractor-M/s Krishna Constructions 182


Design ch-109+720
Design of PSC Girder

H) -ve temperature stresses Load factor = 0.6


Dtop Mpa -1.699 -1.699 -1.699 -1.643 -1.588 -1.588 -1.588 -1.588 -1.588
Deck Dbottom Mpa 0.3901 0.3901 0.3901 0.4567 0.524 0.524 0.524 0.524 0.524
Gtop Mpa 0.3901 0.3901 0.3901 0.4567 0.524 0.524 0.524 0.524 0.524
Girder Gbottom Mpa -1.907 -1.907 -1.907 -1.724 -1.538 -1.538 -1.538 -1.538 -1.538
Total Stresses (A+B +C+D+E+F+G+H) (Without SV)
Dtop Mpa -2.412 -2.295 -2.216 -1.393 -0.559 -0.475 0.1371 0.6971 0.7904
Deck Dbottom Mpa -0.485 -0.393 -0.33 0.3355 0.9949 1.0577 1.5144 1.9323 2.0019
Gtop Mpa 2.2742 2.3758 2.4504 4.2628 7.4945 7.5374 8.4573 9.4099 9.8698
Girder Gbottom Mpa 5.8428 5.6733 5.5521 6.3063 8.2437 8.1163 6.7504 5.4042 4.9819
Total Stresses (A+B +C+D+E+F+G+H) (With SV Loading)
Dtop Mpa -0.713 -0.656 -0.598 0.0119 0.7389 0.8188 1.8014 2.4747 2.5911
Deck Dbottom Mpa -0.875 -0.83 -0.785 -0.305 0.2547 0.3143 1.0476 1.55 1.6369
Gtop Mpa 1.8841 1.9389 1.9961 3.6226 6.7543 6.794 7.9904 9.0276 9.5048
Girder Gbottom Mpa 7.7501 7.6637 7.5733 8.4181 10.334 10.215 8.1427 6.5805 6.114

Max Compressive stress = 10.334 Mpa < 24 Mpa OK


Max Tensile Stress = 1.8841 Mpa >= -3.516 Mpa OK

8.3) Rare Combination LC-SR8.3 : At day 36500 + temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.7963 0.6113 0.4494 -0.305 -0.181 -0.436 -3.577 -5.253 -5.521
Girder Gbottom Mpa 8.3259 8.5203 8.6899 12.346 17.884 18.153 21.573 23.514 23.931

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder Gbottom Mpa 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.1) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.2) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0107 0.0201 0.1063 0.1964 0.2083 0.3559 0.4423 0.4729
Deck Dbottom Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Gtop Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Girder Gbottom Mpa 0 -0.015 -0.028 -0.173 -0.375 -0.397 -0.679 -0.843 -0.902
F) Stresses due to Live load (Without SV) Load factor = 0.75
Dtop Mpa 0 0.0794 0.1321 0.584 0.9815 1.0358 1.3841 1.7393 1.7863
Deck Dbottom Mpa 0 0.0627 0.1044 0.4499 0.7324 0.773 1.0329 1.2979 1.333
Gtop Mpa 0 0.0627 0.1044 0.4499 0.7324 0.773 1.0329 1.2979 1.333
Girder Gbottom Mpa 0 -0.111 -0.185 -0.952 -1.871 -1.975 -2.639 -3.316 -3.406
F.1) Stresses due to Live load (With SV) Load factor = 0.75
Dtop Mpa 0 0.035 0.0712 0.4054 0.7642 0.8152 1.4416 1.8817 1.9461
Deck Dbottom Mpa 0 0.0276 0.0563 0.3123 0.5703 0.6083 1.0757 1.4042 1.4522
Gtop Mpa 0 0.0276 0.0563 0.3123 0.5703 0.6083 1.0757 1.4042 1.4522
Girder

EPC Contractor-M/s Krishna Constructions 183


Design ch-109+720
Design of PSC Girder

Girder Gbottom Mpa 0 -0.049 -0.1 -0.661 -1.457 -1.554 -2.749 -3.588 -3.711

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.713 -0.713 -0.713 -0.635 -0.477 -0.477 -0.477 -0.477 -0.477
Deck Dbottom Mpa -0.875 -0.875 -0.875 -0.803 -0.652 -0.652 -0.652 -0.652 -0.652
Gtop Mpa 1.1035 1.1035 1.1035 1.1759 1.3266 1.3266 1.3266 1.3266 1.3266
Girder Gbottom Mpa -0.592 -0.592 -0.592 -0.58 -0.511 -0.511 -0.511 -0.511 -0.511

H) +ve temperature stresses Load factor = 1


Dtop Mpa 4.52 4.52 4.52 4.6996 4.8808 4.8808 4.8808 4.8808 4.8808
Deck Dbottom Mpa -1.32 -1.32 -1.32 -1.196 -1.071 -1.071 -1.071 -1.071 -1.071
Gtop Mpa -1.32 -1.32 -1.32 -1.196 -1.071 -1.071 -1.071 -1.071 -1.071
Girder Gbottom Mpa 2.8058 2.8058 2.8058 2.3486 1.8872 1.8872 1.8872 1.8872 1.8872
Total Stresses (A+B +C+D+E+F+G+H) (Without SV)
Dtop Mpa 3.8067 3.8967 3.9589 4.7549 5.5822 5.6484 6.1443 6.5859 6.6635
Deck Dbottom Mpa -2.195 -2.124 -2.075 -1.467 -0.844 -0.795 -0.425 -0.096 -0.038
Gtop Mpa 0.5643 0.645 0.7057 2.46 5.6551 5.6846 6.5178 7.382 7.8303
Girder Gbottom Mpa 10.556 10.423 10.327 10.696 12.293 12.2 11.056 9.9351 9.5427
Total Stresses (A+B +C+D+E+F+G+H) (With SV Loading)
Dtop Mpa -0.713 -0.668 -0.622 -0.123 0.4841 0.547 1.3209 1.8474 1.9424
Deck Dbottom Mpa -0.875 -0.839 -0.803 -0.409 0.0646 0.1115 0.689 1.0819 1.1528
Gtop Mpa 1.8841 1.9297 1.9773 3.5185 6.5642 6.5912 7.6319 8.5595 9.0207
Girder Gbottom Mpa 7.7501 7.68 7.6066 8.6384 10.82 10.734 9.0589 7.7764 7.3509

Max Compressive stress = 12.293 Mpa < 24 Mpa OK


Max Tensile Stress = 0.5643 Mpa >= -3.516 Mpa OK

8.4) Rare Combination LC-SR8.4 : At day 36500 - temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.7963 0.6113 0.4494 -0.305 -0.181 -0.436 -3.577 -5.253 -5.521
Girder Gbottom Mpa 8.3259 8.5203 8.6899 12.346 17.884 18.153 21.573 23.514 23.931

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder Gbottom Mpa 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.1) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.2) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0107 0.0201 0.1063 0.1964 0.2083 0.3559 0.4423 0.4729
Deck Dbottom Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Gtop Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Girder Gbottom Mpa 0 -0.015 -0.028 -0.173 -0.375 -0.397 -0.679 -0.843 -0.902
F) Stresses due to Live load (Without SV) Load factor = 0.75
Dtop Mpa 0 0.0794 0.1321 0.584 0.9815 1.0358 1.3841 1.7393 1.7863
Deck

EPC Contractor-M/s Krishna Constructions 184


Design ch-109+720
Design of PSC Girder

Deck Dbottom Mpa 0 0.0627 0.1044 0.4499 0.7324 0.773 1.0329 1.2979 1.333
Gtop Mpa 0 0.0627 0.1044 0.4499 0.7324 0.773 1.0329 1.2979 1.333
Girder Gbottom Mpa 0 -0.111 -0.185 -0.952 -1.871 -1.975 -2.639 -3.316 -3.406
F.1) Stresses due to Live load (With SV) Load factor = 0.75
Dtop Mpa 0 0.035 0.0712 0.4054 0.7642 0.8152 1.4416 1.8817 1.9461
Deck Dbottom Mpa 0 0.0276 0.0563 0.3123 0.5703 0.6083 1.0757 1.4042 1.4522
Gtop Mpa 0 0.0276 0.0563 0.3123 0.5703 0.6083 1.0757 1.4042 1.4522
Girder Gbottom Mpa 0 -0.049 -0.1 -0.661 -1.457 -1.554 -2.749 -3.588 -3.711

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.713 -0.713 -0.713 -0.635 -0.477 -0.477 -0.477 -0.477 -0.477
Deck Dbottom Mpa -0.875 -0.875 -0.875 -0.803 -0.652 -0.652 -0.652 -0.652 -0.652
Gtop Mpa 1.1035 1.1035 1.1035 1.1759 1.3266 1.3266 1.3266 1.3266 1.3266
Girder Gbottom Mpa -0.592 -0.592 -0.592 -0.58 -0.511 -0.511 -0.511 -0.511 -0.511

H) -ve temperature stresses Load factor = 1


Dtop Mpa -2.831 -2.831 -2.831 -2.739 -2.646 -2.646 -2.646 -2.646 -2.646
Deck Dbottom Mpa 0.6502 0.6502 0.6502 0.7612 0.8733 0.8733 0.8733 0.8733 0.8733
Gtop Mpa 0.6502 0.6502 0.6502 0.7612 0.8733 0.8733 0.8733 0.8733 0.8733
Girder Gbottom Mpa -3.179 -3.179 -3.179 -2.873 -2.564 -2.564 -2.564 -2.564 -2.564
Total Stresses (A+B +C+D+E+F+G)
Dtop Mpa -3.544 -3.454 -3.392 -2.684 -1.945 -1.879 -1.383 -0.941 -0.863
Deck Dbottom Mpa -0.225 -0.154 -0.105 0.49 1.1 1.1494 1.5194 1.849 1.9069
Gtop Mpa 2.5343 2.6149 2.6756 4.4173 7.5996 7.6291 8.4623 9.3265 9.7748
Girder Gbottom Mpa 4.5713 4.4389 4.3423 5.4745 7.842 7.7491 6.6046 5.4841 5.0917
Total Stresses (A+B +C+D+E+F+G)
Dtop Mpa -0.713 -0.668 -0.622 -0.123 0.4841 0.547 1.3209 1.8474 1.9424
Deck Dbottom Mpa -0.875 -0.839 -0.803 -0.409 0.0646 0.1115 0.689 1.0819 1.1528
Gtop Mpa 1.8841 1.9297 1.9773 3.5185 6.5642 6.5912 7.6319 8.5595 9.0207
Girder Gbottom Mpa 7.7501 7.68 7.6066 8.6384 10.82 10.734 9.0589 7.7764 7.3509

Max Compressive stress = 10.82 Mpa < 24 Mpa OK


Max Tensile Stress = 1.8841 Mpa >= -3.516 Mpa OK

SUMMARY FOR SLS RARE COMBINATION


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
1) Rare Combination LC-SR1 : At the time of 1st stage prestress, just after ES loss of Stage -I cables
Total Stresses (A+B)
Gtop Mpa -3.253 -3.195 -3.146 -2.681 -1.396 -1.333 -0.533 0.0126 0.2679
Girder Gbottom Mpa 10.282 10.226 10.179 12.005 15.51 15.458 14.815 14.427 14.313
2) Rare Combination LC-SR2 At day 28 Just before II Stage prestressing
Total Stresses (A+B)
Gtop Mpa -3.113 -3.053 -3.002 -2.49 -1.164 -1.096 -0.23 0.3518 0.6182
Girder Gbottom Mpa 9.841 9.7815 9.7317 11.366 14.477 14.419 13.698 13.263 13.121
3) Rare Combination LC-SR3 : At day 28 Just after II Stage prestressing after ES
Total Stresses (A+B)
Gtop Mpa 0.8019 0.7095 0.6259 0.762 2.1583 2.0058 0.1832 -0.645 -0.577
Girder Gbottom Mpa 9.8649 9.9653 10.056 13.515 19.476 19.65 21.803 22.959 23.068
4) Rare Combination LC-SR4 : At day 35 At the time of casting of deck slab
Total Stresses (A+B)
Gtop Mpa 0.733 0.7175 0.7065 1.6806 4.156 4.0917 4.0404 4.3236 4.6723
Girder Gbottom Mpa 9.79 9.8101 9.8251 12.346 17.01 17.09 17.388 17.367 17.183
5) Rare Combination LC-SR5 : At day 63 At the time of transfer over permanent bearings
Total Stresses (A+B)
Gtop Mpa 1.0159 1.0028 0.9942 2.0057 4.5316 4.4726 4.4727 4.7708 5.1185
Girder Gbottom Mpa 9.4831 9.5011 9.5138 11.948 16.45 16.527 16.82 16.82 16.65
6) Rare Combination LC-SR6 : At day 64 At the time of placing of SIDL
Total Stresses (A+B)

EPC Contractor-M/s Krishna Constructions 185


Design ch-109+720
Design of PSC Girder

Gtop Mpa 1.0156 1.0111 1.0101 2.088 4.679 4.629 4.7408 5.1042 5.4747
Girder Gbottom Mpa 9.4795 9.4824 9.4817 11.769 16.064 16.118 16.129 15.963 15.735
7) Rare Combination LC-SR7 : At day 92 Structure open to LL
Total Stresses (A+B)
Gtop Mpa 1.0058 1.0863 1.1421 2.691 5.665 5.6716 6.1574 6.8837 7.3007
Girder Gbottom Mpa 9.4001 9.2532 9.1526 10.368 13.337 13.251 12.365 11.301 10.958
7.1) Rare Combination LC-SR7.1 : At day 92 Structure open to LL + temperature stresses
Total Stresses (A+B)
Gtop Mpa 0.2139 0.2945 0.3502 1.9734 5.0222 5.0289 5.5147 6.241 6.658
Girder Gbottom Mpa 11.084 10.937 10.836 11.778 14.469 14.383 13.498 12.433 12.091
7.2) Rare Combination LC-SR7.2 : At day 92 Structure open to LL - temperature stresses
Total Stresses (A+B)
Gtop Mpa 1.3959 1.4764 1.5322 3.1478 6.1889 6.1956 6.6814 7.4077 7.8247
Girder Gbottom Mpa 7.4927 7.3459 7.2453 8.6449 11.798 11.713 10.827 9.7623 9.4201
7.3) Rare Combination LC-SR7.3 : At day 92 Structure open to LL + temperature stresses
Total Stresses (A+B)
Gtop Mpa -0.314 -0.254 -0.212 1.345 4.3496 4.3427 4.7419 5.3798 5.7852
Girder Gbottom Mpa 12.206 12.096 12.02 13.034 15.848 15.796 15.132 14.293 13.981
7.4) Rare Combination LC-SR7.4 : At day 92 Structure open to LL - temperature stresses
Total Stresses (A+B)
Gtop Mpa 1.656 1.7156 1.7575 3.3023 6.2941 6.2872 6.6864 7.3243 7.7297
Girder Gbottom Mpa 6.2212 6.1115 6.0356 7.8131 11.397 11.345 10.681 9.8422 9.5299

Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
8) Rare Combination LC-SR8 : At day 36500
Total Stresses (A+B)
Gtop Mpa 1.8841 1.9857 2.0603 3.8061 6.9705 7.0135 7.9333 8.8859 9.3458
Girder Gbottom Mpa 7.7501 7.5806 7.4594 8.0299 9.7819 9.6546 8.2887 6.9425 6.5202
8.1) Rare Combination LC-SR8.1 : At day 36500 + temperature stresses
Total Stresses (A+B)
Gtop Mpa 1.0923 1.1938 1.2684 3.0884 6.3278 6.3707 7.2906 8.2432 8.7031
Girder Gbottom Mpa 9.4336 9.264 9.1428 9.439 10.914 10.787 9.421 8.0748 7.6525
8.2) Rare Combination LC-SR8.2 : At day 36500 - temperature stresses
Total Stresses (A+B)
Gtop Mpa 2.2742 2.3758 2.4504 4.2628 7.4945 7.5374 8.4573 9.4099 9.8698
Girder Gbottom Mpa 5.8428 5.6733 5.5521 6.3063 8.2437 8.1163 6.7504 5.4042 4.9819
8.3) Rare Combination LC-SR8.3 : At day 36500 + temperature stresses
Total Stresses (A+B)
Gtop Mpa 0.5643 0.645 0.7057 2.46 5.6551 5.6846 6.5178 7.382 7.8303
Girder Gbottom Mpa 10.556 10.423 10.327 10.696 12.293 12.2 11.056 9.9351 9.5427
8.4) Rare Combination LC-SR8.4 : At day 36500 - temperature stresses
Total Stresses (A+B)
Gtop Mpa 2.5343 2.6149 2.6756 4.4173 7.5996 7.6291 8.4623 9.3265 9.7748
Girder Gbottom Mpa 4.5713 4.4389 4.3423 5.4745 7.842 7.7491 6.6046 5.4841 5.0917

FREQUENT LOAD COMBINATIONS :


1) Frequent Combination LC-SF1 : At day 92 Structure open to LL
Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.7533 0.5473 0.3666 -0.53 -0.482 -0.773 -4.349 -6.251 -6.562
Girder Gbottom Mpa 9.5277 9.7449 9.9351 14.245 21.051 21.362 25.263 27.486 27.983

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder

EPC Contractor-M/s Krishna Constructions 186


Design ch-109+720
Design of PSC Girder

Girder Gbottom Mpa 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0107 0.0201 0.1063 0.1964 0.2083 0.3559 0.4423 0.4729
Deck Dbottom Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Gtop Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Girder Gbottom Mpa 0 -0.015 -0.028 -0.173 -0.375 -0.397 -0.679 -0.843 -0.902
F) Stresses due to Live load (Without SV) Load factor = 0.75
Dtop Mpa 0 0.0794 0.1321 0.584 0.9815 1.0358 1.3841 1.7393 1.7863
Deck Dbottom Mpa 0 0.0627 0.1044 0.4499 0.7324 0.773 1.0329 1.2979 1.333
Gtop Mpa 0 0.0627 0.1044 0.4499 0.7324 0.773 1.0329 1.2979 1.333
Girder Gbottom Mpa 0 -0.111 -0.185 -0.952 -1.871 -1.975 -2.639 -3.316 -3.406
F.1) Stresses due to Live load (With SV) Load factor = 0.75
Dtop Mpa 0 0.035 0.0712 0.4054 0.7642 0.8152 1.4416 1.8817 1.9461
Deck Dbottom Mpa 0 0.0276 0.0563 0.3123 0.5703 0.6083 1.0757 1.4042 1.4522
Gtop Mpa 0 0.0276 0.0563 0.3123 0.5703 0.6083 1.0757 1.4042 1.4522
Girder Gbottom Mpa 0 -0.049 -0.1 -0.661 -1.457 -1.554 -2.749 -3.588 -3.711
G) Stresses due to differential shrinkage Load factor = 1
Dtop Mpa -0.173 -0.173 -0.173 -0.154 -0.116 -0.116 -0.116 -0.116 -0.116
Deck Dbottom Mpa -0.213 -0.213 -0.213 -0.195 -0.158 -0.158 -0.158 -0.158 -0.158
Gtop Mpa 0.2681 0.2681 0.2681 0.2857 0.3223 0.3223 0.3223 0.3223 0.3223
Girder Gbottom Mpa -0.144 -0.144 -0.144 -0.141 -0.124 -0.124 -0.124 -0.124 -0.124
G) Stresses due to wind Load factor = 0.5
Dtop Mpa 0 0.0053 0.0099 0.0523 0.0967 0.1026 0.1752 0.2178 0.2328
Deck Dbottom Mpa 0 0.0042 0.0078 0.0403 0.0722 0.0765 0.1307 0.1625 0.1737
Gtop Mpa 0 0.0042 0.0078 0.0403 0.0722 0.0765 0.1307 0.1625 0.1737
Girder Gbottom Mpa 0 -0.007 -0.014 -0.085 -0.184 -0.196 -0.334 -0.415 -0.444
Total Stresses (A+B +C+D+E+F+G) (Without SV Loading)
Dtop Mpa -0.173 -0.083 -0.021 0.536 1.0622 1.1284 1.6242 2.0658 2.1434
Deck Dbottom Mpa -0.213 -0.142 -0.092 0.3367 0.7205 0.7699 1.14 1.4695 1.5274
Gtop Mpa 1.0058 1.0654 1.1073 2.5411 5.4208 5.414 5.8131 6.4511 6.8564
Girder Gbottom Mpa 9.4001 9.2903 9.2144 10.686 13.961 13.909 13.245 12.406 12.094
Total Stresses (A+B +C+D+E+F+G) (With SV Loading)
Dtop Mpa -0.173 -0.128 -0.082 0.3574 0.8449 0.9078 1.6816 2.2082 2.3032
Deck Dbottom Mpa -0.213 -0.177 -0.141 0.1991 0.5584 0.6053 1.1828 1.5758 1.6466
Gtop Mpa 1.0058 1.0304 1.0592 2.4035 5.2586 5.2493 5.856 6.5573 6.9756
Girder Gbottom Mpa 9.4001 9.3526 9.2999 10.977 14.375 14.33 13.135 12.135 11.789
Total Stresses (A+B +C+D+E+F+G) wind downward
Dtop Mpa -0.173 -0.078 -0.011 0.5884 1.1589 1.2309 1.7994 2.2836 2.3763
Deck Dbottom Mpa -0.213 -0.137 -0.085 0.377 0.7927 0.8465 1.2707 1.632 1.7012
Gtop Mpa 1.0058 1.0696 1.1152 2.5814 5.493 5.4905 5.9439 6.6136 7.0301
Girder Gbottom Mpa 9.4001 9.2829 9.2005 10.601 13.776 13.714 12.911 11.991 11.65
Total Stresses (A+B +C+D+E+F+G) wind upward
Dtop Mpa -0.173 -0.089 -0.031 0.4837 0.9655 1.0258 1.449 1.8481 1.9106
Deck Dbottom Mpa -0.213 -0.146 -0.1 0.2964 0.6484 0.6934 1.0092 1.307 1.3537
Gtop Mpa 1.0058 1.0613 1.0995 2.5007 5.3486 5.3374 5.6824 6.2886 6.6827
Girder Gbottom Mpa 9.4001 9.2977 9.2283 10.771 14.145 14.105 13.579 12.821 12.538
Max Compressive stress = 14.375 Mpa < 24 Mpa OK
Max Tensile Stress = 1.0058 Mpa >= -3.516 Mpa OK
Max Compressive stress (wind downward)= 13.776 Mpa < 24 Mpa OK
Max Tensile Stress (wind downward) = 1.0058 Mpa >= -3.516 Mpa OK
Max Compressive stress (wind upward) = 14.145 Mpa < 24 Mpa OK
Max Tensile Stress (wind upward) = 1.0058 Mpa >= -3.516 Mpa OK

EPC Contractor-M/s Krishna Constructions 187


Design ch-109+720
Design of PSC Girder

1.1) Frequent Combination LC-SF1.1 : At day 92 Structure open to LL + temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.7533 0.5473 0.3666 -0.53 -0.482 -0.773 -4.349 -6.251 -6.562
Girder Gbottom Mpa 9.5277 9.7449 9.9351 14.245 21.051 21.362 25.263 27.486 27.983

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder Gbottom Mpa 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0107 0.0201 0.1063 0.1964 0.2083 0.3559 0.4423 0.4729
Deck Dbottom Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Gtop Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Girder Gbottom Mpa 0 -0.015 -0.028 -0.173 -0.375 -0.397 -0.679 -0.843 -0.902
F) Stresses due to Live load (Without SV) Load factor = 0.75
Dtop Mpa 0 0.0794 0.1321 0.584 0.9815 1.0358 1.3841 1.7393 1.7863
Deck Dbottom Mpa 0 0.0627 0.1044 0.4499 0.7324 0.773 1.0329 1.2979 1.333
Gtop Mpa 0 0.0627 0.1044 0.4499 0.7324 0.773 1.0329 1.2979 1.333
Girder Gbottom Mpa 0 -0.111 -0.185 -0.952 -1.871 -1.975 -2.639 -3.316 -3.406
F.1) Stresses due to Live load (With SV) Load factor = 0.75
Dtop Mpa 0 0.035 0.0712 0.4054 0.7642 0.8152 1.4416 1.8817 1.9461
Deck Dbottom Mpa 0 0.0276 0.0563 0.3123 0.5703 0.6083 1.0757 1.4042 1.4522
Gtop Mpa 0 0.0276 0.0563 0.3123 0.5703 0.6083 1.0757 1.4042 1.4522
Girder Gbottom Mpa 0 -0.049 -0.1 -0.661 -1.457 -1.554 -2.749 -3.588 -3.711

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.173 -0.173 -0.173 -0.154 -0.116 -0.116 -0.116 -0.116 -0.116
Deck Dbottom Mpa -0.213 -0.213 -0.213 -0.195 -0.158 -0.158 -0.158 -0.158 -0.158
Gtop Mpa 0.2681 0.2681 0.2681 0.2857 0.3223 0.3223 0.3223 0.3223 0.3223
Girder Gbottom Mpa -0.144 -0.144 -0.144 -0.141 -0.124 -0.124 -0.124 -0.124 -0.124
H) +ve temperature stresses Load factor = 0.5
Dtop Mpa 2.26 2.26 2.26 2.3498 2.4404 2.4404 2.4404 2.4404 2.4404
Deck Dbottom Mpa -0.66 -0.66 -0.66 -0.598 -0.536 -0.536 -0.536 -0.536 -0.536
Gtop Mpa -0.66 -0.66 -0.66 -0.598 -0.536 -0.536 -0.536 -0.536 -0.536
Girder Gbottom Mpa 1.4029 1.4029 1.4029 1.1743 0.9436 0.9436 0.9436 0.9436 0.9436
Total Stresses (A+B +C+D+E+F+G) (Without SV Loading)
Dtop Mpa 2.0867 2.1767 2.2389 2.8858 3.5026 3.5688 4.0646 4.5062 4.5838
Deck Dbottom Mpa -0.873 -0.801 -0.752 -0.261 0.1849 0.2343 0.6044 0.9339 0.9918
Gtop Mpa 0.3459 0.4055 0.4474 1.943 4.8852 4.8783 5.2775 5.9154 6.3208
Girder Gbottom Mpa 10.803 10.693 10.617 11.86 14.904 14.853 14.189 13.35 13.037
Total Stresses (A+B +C+D+E+F+G) (With SV Loading)
Dtop Mpa -0.173 -0.128 -0.082 0.3574 0.8449 0.9078 1.6816 2.2082 2.3032
Deck Dbottom Mpa -0.213 -0.177 -0.141 0.1991 0.5584 0.6053 1.1828 1.5758 1.6466
Gtop Mpa 1.0058 1.0304 1.0592 2.4035 5.2586 5.2493 5.856 6.5573 6.9756
Girder Gbottom Mpa 9.4001 9.3526 9.2999 10.977 14.375 14.33 13.135 12.135 11.789

Max Compressive stress = 14.904 Mpa < 24 Mpa OK


Max Tensile Stress = 0.3459 Mpa >= -3.516 Mpa OK

EPC Contractor-M/s Krishna Constructions 188


Design ch-109+720
Design of PSC Girder

1.2) Frequent Combination LC-SF1.2 : At day 92 Structure open to LL - temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.7533 0.5473 0.3666 -0.53 -0.482 -0.773 -4.349 -6.251 -6.562
Girder Gbottom Mpa 9.5277 9.7449 9.9351 14.245 21.051 21.362 25.263 27.486 27.983

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder Gbottom Mpa 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0107 0.0201 0.1063 0.1964 0.2083 0.3559 0.4423 0.4729
Deck Dbottom Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Gtop Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Girder Gbottom Mpa 0 -0.015 -0.028 -0.173 -0.375 -0.397 -0.679 -0.843 -0.902
F) Stresses due to Live load (Without SV) Load factor = 0.75
Dtop Mpa 0 0.0794 0.1321 0.584 0.9815 1.0358 1.3841 1.7393 1.7863
Deck Dbottom Mpa 0 0.0627 0.1044 0.4499 0.7324 0.773 1.0329 1.2979 1.333
Gtop Mpa 0 0.0627 0.1044 0.4499 0.7324 0.773 1.0329 1.2979 1.333
Girder Gbottom Mpa 0 -0.111 -0.185 -0.952 -1.871 -1.975 -2.639 -3.316 -3.406
F.1) Stresses due to Live load (With SV) Load factor = 0.75
Dtop Mpa 0 0.035 0.0712 0.4054 0.7642 0.8152 1.4416 1.8817 1.9461
Deck Dbottom Mpa 0 0.0276 0.0563 0.3123 0.5703 0.6083 1.0757 1.4042 1.4522
Gtop Mpa 0 0.0276 0.0563 0.3123 0.5703 0.6083 1.0757 1.4042 1.4522
Girder Gbottom Mpa 0 -0.049 -0.1 -0.661 -1.457 -1.554 -2.749 -3.588 -3.711

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.173 -0.173 -0.173 -0.154 -0.116 -0.116 -0.116 -0.116 -0.116
Deck Dbottom Mpa -0.213 -0.213 -0.213 -0.195 -0.158 -0.158 -0.158 -0.158 -0.158
Gtop Mpa 0.2681 0.2681 0.2681 0.2857 0.3223 0.3223 0.3223 0.3223 0.3223
Girder Gbottom Mpa -0.144 -0.144 -0.144 -0.141 -0.124 -0.124 -0.124 -0.124 -0.124
H) -ve temperature stresses Load factor = 0.5
Dtop Mpa -1.416 -1.416 -1.416 -1.37 -1.323 -1.323 -1.323 -1.323 -1.323
Deck Dbottom Mpa 0.3251 0.3251 0.3251 0.3806 0.4366 0.4366 0.4366 0.4366 0.4366
Gtop Mpa 0.3251 0.3251 0.3251 0.3806 0.4366 0.4366 0.4366 0.4366 0.4366
Girder Gbottom Mpa -1.589 -1.589 -1.589 -1.436 -1.282 -1.282 -1.282 -1.282 -1.282
Total Stresses (A+B +C+D+E+F+G) (Without SV Loading)
Dtop Mpa -1.589 -1.499 -1.437 -0.833 -0.261 -0.195 0.3011 0.7427 0.8203
Deck Dbottom Mpa 0.1124 0.1835 0.2327 0.7173 1.1572 1.2066 1.5766 1.9061 1.9641
Gtop Mpa 1.3309 1.3905 1.4324 2.9217 5.8574 5.8506 6.2498 6.8877 7.293
Girder Gbottom Mpa 7.8106 7.7009 7.625 9.2495 12.679 12.627 11.963 11.124 10.812
Total Stresses (A+B +C+D+E+F+G) (With SV Loading)
Dtop Mpa -0.173 -0.128 -0.082 0.3574 0.8449 0.9078 1.6816 2.2082 2.3032
Deck Dbottom Mpa -0.213 -0.177 -0.141 0.1991 0.5584 0.6053 1.1828 1.5758 1.6466
Gtop Mpa 1.0058 1.0304 1.0592 2.4035 5.2586 5.2493 5.856 6.5573 6.9756
Girder Gbottom Mpa 9.4001 9.3526 9.2999 10.977 14.375 14.33 13.135 12.135 11.789

Max Compressive stress = 14.375 Mpa < 24 Mpa OK


Max Tensile Stress = 1.0058 Mpa >= -3.516 Mpa OK

EPC Contractor-M/s Krishna Constructions 189


Design ch-109+720
Design of PSC Girder

1.3) Frequent Combination LC-SF1.3 : At day 92 Structure open to LL + temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.7533 0.5473 0.3666 -0.53 -0.482 -0.773 -4.349 -6.251 -6.562
Girder Gbottom Mpa 9.5277 9.7449 9.9351 14.245 21.051 21.362 25.263 27.486 27.983

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder Gbottom Mpa 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0107 0.0201 0.1063 0.1964 0.2083 0.3559 0.4423 0.4729
Deck Dbottom Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Gtop Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Girder Gbottom Mpa 0 -0.015 -0.028 -0.173 -0.375 -0.397 -0.679 -0.843 -0.902
F) Stresses due to Live load (Without SV) Load factor = 0.2
Dtop Mpa 0 0.0212 0.0352 0.1557 0.2617 0.2762 0.3691 0.4638 0.4764
Deck Dbottom Mpa 0 0.0167 0.0278 0.12 0.1953 0.2061 0.2754 0.3461 0.3555
Gtop Mpa 0 0.0167 0.0278 0.12 0.1953 0.2061 0.2754 0.3461 0.3555
Girder Gbottom Mpa 0 -0.03 -0.049 -0.254 -0.499 -0.527 -0.704 -0.884 -0.908
F.1) Stresses due to Live load (With SV) Load factor = 0.2
Dtop Mpa 0 0.0093 0.019 0.1081 0.2038 0.2174 0.3844 0.5018 0.519
Deck Dbottom Mpa 0 0.0074 0.015 0.0833 0.1521 0.1622 0.2869 0.3744 0.3873
Gtop Mpa 0 0.0074 0.015 0.0833 0.1521 0.1622 0.2869 0.3744 0.3873
Girder Gbottom Mpa 0 -0.013 -0.027 -0.176 -0.389 -0.415 -0.733 -0.957 -0.99

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.173 -0.173 -0.173 -0.154 -0.116 -0.116 -0.116 -0.116 -0.116
Deck Dbottom Mpa -0.213 -0.213 -0.213 -0.195 -0.158 -0.158 -0.158 -0.158 -0.158
Gtop Mpa 0.2681 0.2681 0.2681 0.2857 0.3223 0.3223 0.3223 0.3223 0.3223
Girder Gbottom Mpa -0.144 -0.144 -0.144 -0.141 -0.124 -0.124 -0.124 -0.124 -0.124
H) +ve temperature stresses Load factor = 0.6
Dtop Mpa 2.712 2.712 2.712 2.8197 2.9285 2.9285 2.9285 2.9285 2.9285
Deck Dbottom Mpa -0.792 -0.792 -0.792 -0.718 -0.643 -0.643 -0.643 -0.643 -0.643
Gtop Mpa -0.792 -0.792 -0.792 -0.718 -0.643 -0.643 -0.643 -0.643 -0.643
Girder Gbottom Mpa 1.6835 1.6835 1.6835 1.4091 1.1323 1.1323 1.1323 1.1323 1.1323
Total Stresses (A+B +C+D+E+F+G) (Without SV Loading)
Dtop Mpa 2.5387 2.5705 2.594 2.9275 3.2709 3.2973 3.5377 3.7188 3.762
Deck Dbottom Mpa -1.005 -0.979 -0.961 -0.711 -0.459 -0.44 -0.26 -0.125 -0.093
Gtop Mpa 0.2139 0.2276 0.2389 1.4935 4.2409 4.2044 4.4129 4.8565 5.2361
Girder Gbottom Mpa 11.084 11.055 11.034 12.793 16.465 16.49 16.313 15.97 15.724
Total Stresses (A+B +C+D+E+F+G) (With SV Loading)
Dtop Mpa -0.173 -0.153 -0.134 0.0601 0.2844 0.3099 0.6245 0.8283 0.8761
Deck Dbottom Mpa -0.213 -0.197 -0.182 -0.03 0.1402 0.1592 0.3939 0.546 0.5817
Gtop Mpa 1.0058 1.0101 1.0179 2.1744 4.8404 4.8032 5.0671 5.5276 5.9106
Girder Gbottom Mpa 9.4001 9.3886 9.3731 11.462 15.443 15.47 15.151 14.766 14.51

Max Compressive stress = 16.49 Mpa < 24 Mpa OK


Max Tensile Stress = 0.2139 Mpa >= -3.516 Mpa OK

EPC Contractor-M/s Krishna Constructions 190


Design ch-109+720
Design of PSC Girder

1.4) Frequent Combination LC-SF1.4 : At day 92 Structure open to LL - temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.7533 0.5473 0.3666 -0.53 -0.482 -0.773 -4.349 -6.251 -6.562
Girder Gbottom Mpa 9.5277 9.7449 9.9351 14.245 21.051 21.362 25.263 27.486 27.983

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder Gbottom Mpa 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0107 0.0201 0.1063 0.1964 0.2083 0.3559 0.4423 0.4729
Deck Dbottom Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Gtop Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Girder Gbottom Mpa 0 -0.015 -0.028 -0.173 -0.375 -0.397 -0.679 -0.843 -0.902
F) Stresses due to Live load (Without SV) Load factor = 0.2
Dtop Mpa 0 0.0212 0.0352 0.1557 0.2617 0.2762 0.3691 0.4638 0.4764
Deck Dbottom Mpa 0 0.0167 0.0278 0.12 0.1953 0.2061 0.2754 0.3461 0.3555
Gtop Mpa 0 0.0167 0.0278 0.12 0.1953 0.2061 0.2754 0.3461 0.3555
Girder Gbottom Mpa 0 -0.03 -0.049 -0.254 -0.499 -0.527 -0.704 -0.884 -0.908
F.1) Stresses due to Live load (With SV) Load factor = 0.2
Dtop Mpa 0 0.0093 0.019 0.1081 0.2038 0.2174 0.3844 0.5018 0.519
Deck Dbottom Mpa 0 0.0074 0.015 0.0833 0.1521 0.1622 0.2869 0.3744 0.3873
Gtop Mpa 0 0.0074 0.015 0.0833 0.1521 0.1622 0.2869 0.3744 0.3873
Girder Gbottom Mpa 0 -0.013 -0.027 -0.176 -0.389 -0.415 -0.733 -0.957 -0.99

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.173 -0.173 -0.173 -0.154 -0.116 -0.116 -0.116 -0.116 -0.116
Deck Dbottom Mpa -0.213 -0.213 -0.213 -0.195 -0.158 -0.158 -0.158 -0.158 -0.158
Gtop Mpa 0.2681 0.2681 0.2681 0.2857 0.3223 0.3223 0.3223 0.3223 0.3223
Girder Gbottom Mpa -0.144 -0.144 -0.144 -0.141 -0.124 -0.124 -0.124 -0.124 -0.124
H) -ve temperature stresses Load factor = 0.6
Dtop Mpa -1.699 -1.699 -1.699 -1.643 -1.588 -1.588 -1.588 -1.588 -1.588
Deck Dbottom Mpa 0.3901 0.3901 0.3901 0.4567 0.524 0.524 0.524 0.524 0.524
Gtop Mpa 0.3901 0.3901 0.3901 0.4567 0.524 0.524 0.524 0.524 0.524
Girder Gbottom Mpa -1.907 -1.907 -1.907 -1.724 -1.538 -1.538 -1.538 -1.538 -1.538
Total Stresses (A+B +C+D+E+F+G) (Without SV Loading)
Dtop Mpa -1.872 -1.84 -1.817 -1.536 -1.245 -1.219 -0.979 -0.797 -0.754
Deck Dbottom Mpa 0.1774 0.2026 0.2211 0.4635 0.7074 0.7271 0.9065 1.0417 1.0739
Gtop Mpa 1.3959 1.4096 1.4209 2.6678 5.4076 5.3711 5.5796 6.0232 6.4028
Girder Gbottom Mpa 7.4927 7.4647 7.443 9.6604 13.795 13.819 13.642 13.3 13.053
Total Stresses (A+B +C+D+E+F+G) (With SV Loading)
Dtop Mpa -0.173 -0.153 -0.134 0.0601 0.2844 0.3099 0.6245 0.8283 0.8761
Deck Dbottom Mpa -0.213 -0.197 -0.182 -0.03 0.1402 0.1592 0.3939 0.546 0.5817
Gtop Mpa 1.0058 1.0101 1.0179 2.1744 4.8404 4.8032 5.0671 5.5276 5.9106
Girder Gbottom Mpa 9.4001 9.3886 9.3731 11.462 15.443 15.47 15.151 14.766 14.51

Max Compressive stress = 15.47 Mpa < 24 Mpa OK


Max Tensile Stress = 1.0058 Mpa >= -3.516 Mpa OK

EPC Contractor-M/s Krishna Constructions 191


Design ch-109+720
Design of PSC Girder

2) Frequent Combination LC-SF2 : At day 36500


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.7963 0.6113 0.4494 -0.305 -0.181 -0.436 -3.577 -5.253 -5.521
Girder Gbottom Mpa 8.3259 8.5203 8.6899 12.346 17.884 18.153 21.573 23.514 23.931

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder Gbottom Mpa 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.1) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.2) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0107 0.0201 0.1063 0.1964 0.2083 0.3559 0.4423 0.4729
Deck Dbottom Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Gtop Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Girder Gbottom Mpa 0 -0.015 -0.028 -0.173 -0.375 -0.397 -0.679 -0.843 -0.902
F) Stresses due to Live load (Without SV) Load factor = 0.75
Dtop Mpa 0 0.0794 0.1321 0.584 0.9815 1.0358 1.3841 1.7393 1.7863
Deck Dbottom Mpa 0 0.0627 0.1044 0.4499 0.7324 0.773 1.0329 1.2979 1.333
Gtop Mpa 0 0.0627 0.1044 0.4499 0.7324 0.773 1.0329 1.2979 1.333
Girder Gbottom Mpa 0 -0.111 -0.185 -0.952 -1.871 -1.975 -2.639 -3.316 -3.406
F.1) Stresses due to Live load (With SV) Load factor = 0.75
Dtop Mpa 0 0.035 0.0712 0.4054 0.7642 0.8152 1.4416 1.8817 1.9461
Deck Dbottom Mpa 0 0.0276 0.0563 0.3123 0.5703 0.6083 1.0757 1.4042 1.4522
Gtop Mpa 0 0.0276 0.0563 0.3123 0.5703 0.6083 1.0757 1.4042 1.4522
Girder Gbottom Mpa 0 -0.049 -0.1 -0.661 -1.457 -1.554 -2.749 -3.588 -3.711

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.713 -0.713 -0.713 -0.635 -0.477 -0.477 -0.477 -0.477 -0.477
Deck Dbottom Mpa -0.875 -0.875 -0.875 -0.803 -0.652 -0.652 -0.652 -0.652 -0.652
Gtop Mpa 1.1035 1.1035 1.1035 1.1759 1.3266 1.3266 1.3266 1.3266 1.3266
Girder Gbottom Mpa -0.592 -0.592 -0.592 -0.58 -0.511 -0.511 -0.511 -0.511 -0.511
Total Stresses (A+B +C+D+E+F+G) (Without SV Loading)
Dtop Mpa -0.713 -0.623 -0.561 0.0553 0.7014 0.7676 1.2635 1.7051 1.7827
Deck Dbottom Mpa -0.875 -0.804 -0.755 -0.271 0.2267 0.2761 0.6461 0.9757 1.0336
Gtop Mpa 1.8841 1.9648 2.0255 3.6561 6.7263 6.7558 7.589 8.4532 8.9015
Girder Gbottom Mpa 7.7501 7.6177 7.5212 8.3472 10.406 10.313 9.1684 8.0479 7.6555
Total Stresses (A+B +C+D+E+F+G) (With SV Loading)
Dtop Mpa -0.713 -0.668 -0.622 -0.123 0.4841 0.547 1.3209 1.8474 1.9424
Deck Dbottom Mpa -0.875 -0.839 -0.803 -0.409 0.0646 0.1115 0.689 1.0819 1.1528
Gtop Mpa 1.8841 1.9297 1.9773 3.5185 6.5642 6.5912 7.6319 8.5595 9.0207
Girder Gbottom Mpa 7.7501 7.68 7.6066 8.6384 10.82 10.734 9.0589 7.7764 7.3509

Max Compressive stress = 10.82 Mpa < 24 Mpa OK


Max Tensile Stress = 1.8841 Mpa >= -3.516 Mpa OK

EPC Contractor-M/s Krishna Constructions 192


Design ch-109+720
Design of PSC Girder

2.1) Frequent Combination LC-SF2.1 : At day 36500 + temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.7963 0.6113 0.4494 -0.305 -0.181 -0.436 -3.577 -5.253 -5.521
Girder Gbottom Mpa 8.3259 8.5203 8.6899 12.346 17.884 18.153 21.573 23.514 23.931

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder Gbottom Mpa 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.1) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.2) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0107 0.0201 0.1063 0.1964 0.2083 0.3559 0.4423 0.4729
Deck Dbottom Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Gtop Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Girder Gbottom Mpa 0 -0.015 -0.028 -0.173 -0.375 -0.397 -0.679 -0.843 -0.902
F) Stresses due to Live load (Without SV) Load factor = 0.75
Dtop Mpa 0 0.0794 0.1321 0.584 0.9815 1.0358 1.3841 1.7393 1.7863
Deck Dbottom Mpa 0 0.0627 0.1044 0.4499 0.7324 0.773 1.0329 1.2979 1.333
Gtop Mpa 0 0.0627 0.1044 0.4499 0.7324 0.773 1.0329 1.2979 1.333
Girder Gbottom Mpa 0 -0.111 -0.185 -0.952 -1.871 -1.975 -2.639 -3.316 -3.406
F.1) Stresses due to Live load (With SV) Load factor = 0.75
Dtop Mpa 0 0.035 0.0712 0.4054 0.7642 0.8152 1.4416 1.8817 1.9461
Deck Dbottom Mpa 0 0.0276 0.0563 0.3123 0.5703 0.6083 1.0757 1.4042 1.4522
Gtop Mpa 0 0.0276 0.0563 0.3123 0.5703 0.6083 1.0757 1.4042 1.4522
Girder Gbottom Mpa 0 -0.049 -0.1 -0.661 -1.457 -1.554 -2.749 -3.588 -3.711
G) Stresses due to differential shrinkage Load factor = 1
Dtop Mpa -0.713 -0.713 -0.713 -0.635 -0.477 -0.477 -0.477 -0.477 -0.477
Deck Dbottom Mpa -0.875 -0.875 -0.875 -0.803 -0.652 -0.652 -0.652 -0.652 -0.652
Gtop Mpa 1.1035 1.1035 1.1035 1.1759 1.3266 1.3266 1.3266 1.3266 1.3266
Girder Gbottom Mpa -0.592 -0.592 -0.592 -0.58 -0.511 -0.511 -0.511 -0.511 -0.511
H) +ve temperature stresses Load factor = 0.5
Dtop Mpa 2.26 2.26 2.26 2.3498 2.4404 2.4404 2.4404 2.4404 2.4404
Deck Dbottom Mpa -0.66 -0.66 -0.66 -0.598 -0.536 -0.536 -0.536 -0.536 -0.536
Gtop Mpa -0.66 -0.66 -0.66 -0.598 -0.536 -0.536 -0.536 -0.536 -0.536
Girder Gbottom Mpa 1.4029 1.4029 1.4029 1.1743 0.9436 0.9436 0.9436 0.9436 0.9436
Total Stresses (A+B +C+D+E+F+G) (Without SV Loading)
Dtop Mpa 1.5467 1.6367 1.6989 2.4051 3.1418 3.208 3.7039 4.1455 4.2231
Deck Dbottom Mpa -1.535 -1.464 -1.415 -0.869 -0.309 -0.259 0.1105 0.4401 0.498
Gtop Mpa 1.2242 1.3049 1.3656 3.058 6.1907 6.2202 7.0534 7.9176 8.3659
Girder Gbottom Mpa 9.153 9.0206 8.924 9.5215 11.349 11.256 10.112 8.9915 8.5991
Total Stresses (A+B +C+D+E+F+G) (With SV Loading)
Dtop Mpa -0.713 -0.668 -0.622 -0.123 0.4841 0.547 1.3209 1.8474 1.9424
Deck Dbottom Mpa -0.875 -0.839 -0.803 -0.409 0.0646 0.1115 0.689 1.0819 1.1528
Gtop Mpa 1.8841 1.9297 1.9773 3.5185 6.5642 6.5912 7.6319 8.5595 9.0207
Girder Gbottom Mpa 7.7501 7.68 7.6066 8.6384 10.82 10.734 9.0589 7.7764 7.3509

Max Compressive stress = 11.349 Mpa < 24 Mpa OK


Max Tensile Stress = 1.2242 Mpa >= -3.516 Mpa OK

EPC Contractor-M/s Krishna Constructions 193


Design ch-109+720
Design of PSC Girder

2.2) Frequent Combination LC-S2.2 : At day 36500 - temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.7963 0.6113 0.4494 -0.305 -0.181 -0.436 -3.577 -5.253 -5.521
Girder Gbottom Mpa 8.3259 8.5203 8.6899 12.346 17.884 18.153 21.573 23.514 23.931

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder Gbottom Mpa 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.1) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.2) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0107 0.0201 0.1063 0.1964 0.2083 0.3559 0.4423 0.4729
Deck Dbottom Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Gtop Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Girder Gbottom Mpa 0 -0.015 -0.028 -0.173 -0.375 -0.397 -0.679 -0.843 -0.902
F) Stresses due to Live load (Without SV) Load factor = 0.75
Dtop Mpa 0 0.0794 0.1321 0.584 0.9815 1.0358 1.3841 1.7393 1.7863
Deck Dbottom Mpa 0 0.0627 0.1044 0.4499 0.7324 0.773 1.0329 1.2979 1.333
Gtop Mpa 0 0.0627 0.1044 0.4499 0.7324 0.773 1.0329 1.2979 1.333
Girder Gbottom Mpa 0 -0.111 -0.185 -0.952 -1.871 -1.975 -2.639 -3.316 -3.406
F.1) Stresses due to Live load (With SV) Load factor = 0.75
Dtop Mpa 0 0.035 0.0712 0.4054 0.7642 0.8152 1.4416 1.8817 1.9461
Deck Dbottom Mpa 0 0.0276 0.0563 0.3123 0.5703 0.6083 1.0757 1.4042 1.4522
Gtop Mpa 0 0.0276 0.0563 0.3123 0.5703 0.6083 1.0757 1.4042 1.4522
Girder Gbottom Mpa 0 -0.049 -0.1 -0.661 -1.457 -1.554 -2.749 -3.588 -3.711
G) Stresses due to differential shrinkage Load factor = 1
Dtop Mpa -0.713 -0.713 -0.713 -0.635 -0.477 -0.477 -0.477 -0.477 -0.477
Deck Dbottom Mpa -0.875 -0.875 -0.875 -0.803 -0.652 -0.652 -0.652 -0.652 -0.652
Gtop Mpa 1.1035 1.1035 1.1035 1.1759 1.3266 1.3266 1.3266 1.3266 1.3266
Girder Gbottom Mpa -0.592 -0.592 -0.592 -0.58 -0.511 -0.511 -0.511 -0.511 -0.511
H) -ve temperature stresses Load factor = 0.5
Dtop Mpa -1.416 -1.416 -1.416 -1.37 -1.323 -1.323 -1.323 -1.323 -1.323
Deck Dbottom Mpa 0.3251 0.3251 0.3251 0.3806 0.4366 0.4366 0.4366 0.4366 0.4366
Gtop Mpa 0.3251 0.3251 0.3251 0.3806 0.4366 0.4366 0.4366 0.4366 0.4366
Girder Gbottom Mpa -1.589 -1.589 -1.589 -1.436 -1.282 -1.282 -1.282 -1.282 -1.282
Total Stresses (A+B +C+D+E+F+G) (Without SV Loading)
Dtop Mpa -2.129 -2.039 -1.977 -1.314 -0.622 -0.555 -0.06 0.382 0.4596
Deck Dbottom Mpa -0.55 -0.479 -0.43 0.1094 0.6634 0.7128 1.0828 1.4123 1.4703
Gtop Mpa 2.2092 2.2898 2.3506 4.0367 7.163 7.1924 8.0256 8.8899 9.3381
Girder Gbottom Mpa 6.1607 6.0283 5.9317 6.9109 9.1239 9.031 7.8865 6.766 6.3736
Total Stresses (A+B +C+D+E+F+G) (With SV Loading)
Dtop Mpa -0.713 -0.668 -0.622 -0.123 0.4841 0.547 1.3209 1.8474 1.9424
Deck Dbottom Mpa -0.875 -0.839 -0.803 -0.409 0.0646 0.1115 0.689 1.0819 1.1528
Gtop Mpa 1.8841 1.9297 1.9773 3.5185 6.5642 6.5912 7.6319 8.5595 9.0207
Girder Gbottom Mpa 7.7501 7.68 7.6066 8.6384 10.82 10.734 9.0589 7.7764 7.3509

Max Compressive stress = 10.82 Mpa < 24 Mpa OK


Max Tensile Stress = 1.8841 Mpa >= -3.516 Mpa OK

EPC Contractor-M/s Krishna Constructions 194


Design ch-109+720
Design of PSC Girder

2.3) Frequent Combination LC-SF2.3 : At day 36500 + temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.7963 0.6113 0.4494 -0.305 -0.181 -0.436 -3.577 -5.253 -5.521
Girder Gbottom Mpa 8.3259 8.5203 8.6899 12.346 17.884 18.153 21.573 23.514 23.931

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder Gbottom Mpa 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.1) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.2) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0107 0.0201 0.1063 0.1964 0.2083 0.3559 0.4423 0.4729
Deck Dbottom Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Gtop Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Girder Gbottom Mpa 0 -0.015 -0.028 -0.173 -0.375 -0.397 -0.679 -0.843 -0.902
F) Stresses due to Live load (Without SV) Load factor = 0.2
Dtop Mpa 0 0.0212 0.0352 0.1557 0.2617 0.2762 0.3691 0.4638 0.4764
Deck Dbottom Mpa 0 0.0167 0.0278 0.12 0.1953 0.2061 0.2754 0.3461 0.3555
Gtop Mpa 0 0.0167 0.0278 0.12 0.1953 0.2061 0.2754 0.3461 0.3555
Girder Gbottom Mpa 0 -0.03 -0.049 -0.254 -0.499 -0.527 -0.704 -0.884 -0.908
F.1) Stresses due to Live load (With SV) Load factor = 0.2
Dtop Mpa 0 0.0093 0.019 0.1081 0.2038 0.2174 0.3844 0.5018 0.519
Deck Dbottom Mpa 0 0.0074 0.015 0.0833 0.1521 0.1622 0.2869 0.3744 0.3873
Gtop Mpa 0 0.0074 0.015 0.0833 0.1521 0.1622 0.2869 0.3744 0.3873
Girder Gbottom Mpa 0 -0.013 -0.027 -0.176 -0.389 -0.415 -0.733 -0.957 -0.99

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.713 -0.713 -0.713 -0.635 -0.477 -0.477 -0.477 -0.477 -0.477
Deck Dbottom Mpa -0.875 -0.875 -0.875 -0.803 -0.652 -0.652 -0.652 -0.652 -0.652
Gtop Mpa 1.1035 1.1035 1.1035 1.1759 1.3266 1.3266 1.3266 1.3266 1.3266
Girder Gbottom Mpa -0.592 -0.592 -0.592 -0.58 -0.511 -0.511 -0.511 -0.511 -0.511
H) +ve temperature stresses Load factor = 0.6
Dtop Mpa 2.712 2.712 2.712 2.8197 2.9285 2.9285 2.9285 2.9285 2.9285
Deck Dbottom Mpa -0.792 -0.792 -0.792 -0.718 -0.643 -0.643 -0.643 -0.643 -0.643
Gtop Mpa -0.792 -0.792 -0.792 -0.718 -0.643 -0.643 -0.643 -0.643 -0.643
Girder Gbottom Mpa 1.6835 1.6835 1.6835 1.4091 1.1323 1.1323 1.1323 1.1323 1.1323
Total Stresses (A+B +C+D+E+F+G) (Without SV Loading)
Dtop Mpa 1.9987 2.0305 2.054 2.4468 2.9101 2.9365 3.1769 3.3581 3.4012
Deck Dbottom Mpa -1.667 -1.642 -1.624 -1.319 -0.953 -0.933 -0.754 -0.619 -0.587
Gtop Mpa 1.0923 1.1269 1.157 2.6085 5.5465 5.5462 6.1888 6.8587 7.2812
Girder Gbottom Mpa 9.4336 9.3828 9.3406 10.455 12.91 12.894 12.236 11.612 11.286
Total Stresses (A+B +C+D+E+F+G) (With SV Loading)
Dtop Mpa -0.713 -0.693 -0.674 -0.421 -0.076 -0.051 0.2637 0.4676 0.5153
Deck Dbottom Mpa -0.875 -0.86 -0.845 -0.638 -0.354 -0.335 -0.1 0.0522 0.0879
Gtop Mpa 1.8841 1.9094 1.9361 3.2894 6.146 6.1451 6.843 7.5298 7.9557
Girder Gbottom Mpa 7.7501 7.716 7.6799 9.1231 11.889 11.873 11.075 10.407 10.072

Max Compressive stress = 12.91 Mpa < 24 Mpa OK


Max Tensile Stress = 1.0923 Mpa >= -3.516 Mpa OK

EPC Contractor-M/s Krishna Constructions 195


Design ch-109+720
Design of PSC Girder

2.4) Frequent Combination LC-SF2.4 : At day 36500 - temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.7963 0.6113 0.4494 -0.305 -0.181 -0.436 -3.577 -5.253 -5.521
Girder Gbottom Mpa 8.3259 8.5203 8.6899 12.346 17.884 18.153 21.573 23.514 23.931

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder Gbottom Mpa 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.1) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.2) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0107 0.0201 0.1063 0.1964 0.2083 0.3559 0.4423 0.4729
Deck Dbottom Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Gtop Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Girder Gbottom Mpa 0 -0.015 -0.028 -0.173 -0.375 -0.397 -0.679 -0.843 -0.902
F) Stresses due to Live load (Without SV) Load factor = 0.2
Dtop Mpa 0 0.0212 0.0352 0.1557 0.2617 0.2762 0.3691 0.4638 0.4764
Deck Dbottom Mpa 0 0.0167 0.0278 0.12 0.1953 0.2061 0.2754 0.3461 0.3555
Gtop Mpa 0 0.0167 0.0278 0.12 0.1953 0.2061 0.2754 0.3461 0.3555
Girder Gbottom Mpa 0 -0.03 -0.049 -0.254 -0.499 -0.527 -0.704 -0.884 -0.908
F.1) Stresses due to Live load (With SV) Load factor = 0.2
Dtop Mpa 0 0.0093 0.019 0.1081 0.2038 0.2174 0.3844 0.5018 0.519
Deck Dbottom Mpa 0 0.0074 0.015 0.0833 0.1521 0.1622 0.2869 0.3744 0.3873
Gtop Mpa 0 0.0074 0.015 0.0833 0.1521 0.1622 0.2869 0.3744 0.3873
Girder Gbottom Mpa 0 -0.013 -0.027 -0.176 -0.389 -0.415 -0.733 -0.957 -0.99
G) Stresses due to differential shrinkage Load factor = 1
Dtop Mpa -0.713 -0.713 -0.713 -0.635 -0.477 -0.477 -0.477 -0.477 -0.477
Deck Dbottom Mpa -0.875 -0.875 -0.875 -0.803 -0.652 -0.652 -0.652 -0.652 -0.652
Gtop Mpa 1.1035 1.1035 1.1035 1.1759 1.3266 1.3266 1.3266 1.3266 1.3266
Girder Gbottom Mpa -0.592 -0.592 -0.592 -0.58 -0.511 -0.511 -0.511 -0.511 -0.511
H) -ve temperature stresses Load factor = 0.6
Dtop Mpa -1.699 -1.699 -1.699 -1.643 -1.588 -1.588 -1.588 -1.588 -1.588
Deck Dbottom Mpa 0.3901 0.3901 0.3901 0.4567 0.524 0.524 0.524 0.524 0.524
Gtop Mpa 0.3901 0.3901 0.3901 0.4567 0.524 0.524 0.524 0.524 0.524
Girder Gbottom Mpa -1.907 -1.907 -1.907 -1.724 -1.538 -1.538 -1.538 -1.538 -1.538
Total Stresses (A+B +C+D+E+F+G) (Without SV Loading)
Dtop Mpa -2.412 -2.38 -2.357 -2.016 -1.606 -1.58 -1.339 -1.158 -1.115
Deck Dbottom Mpa -0.485 -0.46 -0.442 -0.144 0.2136 0.2333 0.4127 0.5478 0.58
Gtop Mpa 2.2742 2.3089 2.339 3.7829 6.7132 6.7129 7.3555 8.0254 8.4479
Girder Gbottom Mpa 5.8428 5.7921 5.7498 7.3218 10.24 10.223 9.5655 8.9416 8.615
Total Stresses (A+B +C+D+E+F+G) (With SV Loading)
Dtop Mpa -0.713 -0.693 -0.674 -0.421 -0.076 -0.051 0.2637 0.4676 0.5153
Deck Dbottom Mpa -0.875 -0.86 -0.845 -0.638 -0.354 -0.335 -0.1 0.0522 0.0879
Gtop Mpa 1.8841 1.9094 1.9361 3.2894 6.146 6.1451 6.843 7.5298 7.9557
Girder Gbottom Mpa 7.7501 7.716 7.6799 9.1231 11.889 11.873 11.075 10.407 10.072

Max Compressive stress = 11.889 Mpa < 24 Mpa OK


Max Tensile Stress = 1.8841 Mpa >= -3.516 Mpa OK

EPC Contractor-M/s Krishna Constructions 196


Design ch-109+720
Design of PSC Girder

SUMMARY FOR SLS FREQUENT COMBINATION


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
1) Frequent Combination LC-SF1 : At day 92 Structure open to LL
Total Stresses (A+B)
Gtop Mpa 1.0058 1.0654 1.1073 2.5411 5.4208 5.414 5.8131 6.4511 6.8564
Girder Gbottom Mpa 9.4001 9.2903 9.2144 10.686 13.961 13.909 13.245 12.406 12.094
1.1) Frequent Combination LC-SF1.1 : At day 92 Structure open to LL + temperature stresses
Total Stresses (A+B)
Gtop Mpa 0.3459 0.4055 0.4474 1.943 4.8852 4.8783 5.2775 5.9154 6.3208
Girder Gbottom Mpa 10.803 10.693 10.617 11.86 14.904 14.853 14.189 13.35 13.037
1.2) Frequent Combination LC-SF1.2 : At day 92 Structure open to LL - temperature stresses
Total Stresses (A+B)
Gtop Mpa 1.3309 1.3905 1.4324 2.9217 5.8574 5.8506 6.2498 6.8877 7.293
Girder Gbottom Mpa 7.8106 7.7009 7.625 9.2495 12.679 12.627 11.963 11.124 10.812
1.3) Frequent Combination LC-SF1.3 : At day 92 Structure open to LL + temperature stresses
Total Stresses (A+B)
Gtop Mpa 0.2139 0.2276 0.2389 1.4935 4.2409 4.2044 4.4129 4.8565 5.2361
Girder Gbottom Mpa 11.084 11.055 11.034 12.793 16.465 16.49 16.313 15.97 15.724
1.4) Frequent Combination LC-SF1.4 : At day 92 Structure open to LL - temperature stresses
Total Stresses (A+B)
Gtop Mpa 1.3959 1.4096 1.4209 2.6678 5.4076 5.3711 5.5796 6.0232 6.4028
Girder Gbottom Mpa 7.4927 7.4647 7.443 9.6604 13.795 13.819 13.642 13.3 13.053
2) Frequent Combination LC-SF2 : At day 36500
Total Stresses (A+B)
Gtop Mpa 1.8841 1.9648 2.0255 3.6561 6.7263 6.7558 7.589 8.4532 8.9015
Girder Gbottom Mpa 7.7501 7.6177 7.5212 8.3472 10.406 10.313 9.1684 8.0479 7.6555
2.1) Frequent Combination LC-SF2.1 : At day 36500 + temperature stresses
Total Stresses (A+B)
Gtop Mpa 1.2242 1.3049 1.3656 3.058 6.1907 6.2202 7.0534 7.9176 8.3659
Girder Gbottom Mpa 9.153 9.0206 8.924 9.5215 11.349 11.256 10.112 8.9915 8.5991
2.2) Frequent Combination LC-S2.2 : At day 36500 - temperature stresses
Total Stresses (A+B)
Gtop Mpa 2.2092 2.2898 2.3506 4.0367 7.163 7.1924 8.0256 8.8899 9.3381
Girder Gbottom Mpa 6.1607 6.0283 5.9317 6.9109 9.1239 9.031 7.8865 6.766 6.3736
2.3) Frequent Combination LC-SF2.3 : At day 36500 + temperature stresses
Total Stresses (A+B)
Gtop Mpa 1.0923 1.1269 1.157 2.6085 5.5465 5.5462 6.1888 6.8587 7.2812
Girder Gbottom Mpa 9.4336 9.3828 9.3406 10.455 12.91 12.894 12.236 11.612 11.286
2.4) Frequent Combination LC-SF2.4 : At day 36500 - temperature stresses
Total Stresses (A+B)
Gtop Mpa 2.2742 2.3089 2.339 3.7829 6.7132 6.7129 7.3555 8.0254 8.4479
Girder Gbottom Mpa 5.8428 5.7921 5.7498 7.3218 10.24 10.223 9.5655 8.9416 8.615

QUASI PERMANENT LOAD COMBINATION


1) QSP Combination LC-SQ1 : At day 92 Structure open to LL
Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.7533 0.5473 0.3666 -0.53 -0.482 -0.773 -4.349 -6.251 -6.562
Girder Gbottom Mpa 9.5277 9.7449 9.9351 14.245 21.051 21.362 25.263 27.486 27.983

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder Gbottom Mpa 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder

EPC Contractor-M/s Krishna Constructions 197


Design ch-109+720
Design of PSC Girder

Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0


E) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0107 0.0201 0.1063 0.1964 0.2083 0.3559 0.4423 0.4729
Deck Dbottom Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Gtop Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Girder Gbottom Mpa 0 -0.015 -0.028 -0.173 -0.375 -0.397 -0.679 -0.843 -0.902
F) Stresses due to Live load Load factor = 0
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.173 -0.173 -0.173 -0.154 -0.116 -0.116 -0.116 -0.116 -0.116
Deck Dbottom Mpa -0.213 -0.213 -0.213 -0.195 -0.158 -0.158 -0.158 -0.158 -0.158
Gtop Mpa 0.2681 0.2681 0.2681 0.2857 0.3223 0.3223 0.3223 0.3223 0.3223
Girder Gbottom Mpa -0.144 -0.144 -0.144 -0.141 -0.124 -0.124 -0.124 -0.124 -0.124
Total Stresses (A+B +C+D+E+F+G)
Dtop Mpa -0.173 -0.163 -0.153 -0.048 0.0807 0.0926 0.2401 0.3265 0.3571
Deck Dbottom Mpa -0.213 -0.204 -0.197 -0.113 -0.012 -0.003 0.1071 0.1716 0.1944
Gtop Mpa 1.0058 1.0027 1.0029 2.0911 4.6884 4.641 4.7802 5.1531 5.5234
Girder Gbottom Mpa 9.4001 9.4017 9.3998 11.638 15.832 15.884 15.884 15.722 15.5

Max Compressive stress = 15.884 Mpa < 24 Mpa OK


Max Tensile Stress = 1.0027 Mpa >= -3.516 Mpa OK

1.1) QSP Combination LC-SQ1.1 : At day 92 Structure open to LL + temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.7533 0.5473 0.3666 -0.53 -0.482 -0.773 -4.349 -6.251 -6.562
Girder Gbottom Mpa 9.5277 9.7449 9.9351 14.245 21.051 21.362 25.263 27.486 27.983

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder Gbottom Mpa 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0107 0.0201 0.1063 0.1964 0.2083 0.3559 0.4423 0.4729
Deck Dbottom Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Gtop Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Girder Gbottom Mpa 0 -0.015 -0.028 -0.173 -0.375 -0.397 -0.679 -0.843 -0.902
F) Stresses due to Live load Load factor = 0
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder

EPC Contractor-M/s Krishna Constructions 198


Design ch-109+720
Design of PSC Girder

Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.173 -0.173 -0.173 -0.154 -0.116 -0.116 -0.116 -0.116 -0.116
Deck Dbottom Mpa -0.213 -0.213 -0.213 -0.195 -0.158 -0.158 -0.158 -0.158 -0.158
Gtop Mpa 0.2681 0.2681 0.2681 0.2857 0.3223 0.3223 0.3223 0.3223 0.3223
Girder Gbottom Mpa -0.144 -0.144 -0.144 -0.141 -0.124 -0.124 -0.124 -0.124 -0.124
H) +ve temperature stresses Load factor = 0.5
Dtop Mpa 2.26 2.26 2.26 2.3498 2.4404 2.4404 2.4404 2.4404 2.4404
Deck Dbottom Mpa -0.66 -0.66 -0.66 -0.598 -0.536 -0.536 -0.536 -0.536 -0.536
Gtop Mpa -0.66 -0.66 -0.66 -0.598 -0.536 -0.536 -0.536 -0.536 -0.536
Girder Gbottom Mpa 1.4029 1.4029 1.4029 1.1743 0.9436 0.9436 0.9436 0.9436 0.9436
Total Stresses (A+B +C+D+E+F+G)
Dtop Mpa 2.0867 2.0973 2.1068 2.3018 2.5211 2.533 2.6805 2.7669 2.7975
Deck Dbottom Mpa -0.873 -0.864 -0.857 -0.711 -0.548 -0.539 -0.429 -0.364 -0.341
Gtop Mpa 0.3459 0.3428 0.343 1.4931 4.1527 4.1054 4.2446 4.6175 4.9878
Girder Gbottom Mpa 10.803 10.805 10.803 12.812 16.776 16.828 16.828 16.666 16.443

Max Compressive stress = 16.828 Mpa < 18 Mpa OK


Max Tensile Stress = 0.3428 Mpa >= -3.516 Mpa OK

1.2) QSP Combination LC-SQ1.2 : At day 92 Structure open to LL - temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.7533 0.5473 0.3666 -0.53 -0.482 -0.773 -4.349 -6.251 -6.562
Girder Gbottom Mpa 9.5277 9.7449 9.9351 14.245 21.051 21.362 25.263 27.486 27.983

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder Gbottom Mpa 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0107 0.0201 0.1063 0.1964 0.2083 0.3559 0.4423 0.4729
Deck Dbottom Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Gtop Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Girder Gbottom Mpa 0 -0.015 -0.028 -0.173 -0.375 -0.397 -0.679 -0.843 -0.902
F) Stresses due to Live load Load factor = 0
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
G) Stresses due to differential shrinkage Load factor = 1
Dtop Mpa -0.173 -0.173 -0.173 -0.154 -0.116 -0.116 -0.116 -0.116 -0.116
Deck Dbottom Mpa -0.213 -0.213 -0.213 -0.195 -0.158 -0.158 -0.158 -0.158 -0.158
Gtop Mpa 0.2681 0.2681 0.2681 0.2857 0.3223 0.3223 0.3223 0.3223 0.3223
Girder Gbottom Mpa -0.144 -0.144 -0.144 -0.141 -0.124 -0.124 -0.124 -0.124 -0.124
H) -ve temperature stresses Load factor = 0.5
Dtop Mpa -1.416 -1.416 -1.416 -1.37 -1.323 -1.323 -1.323 -1.323 -1.323
Deck Dbottom Mpa 0.3251 0.3251 0.3251 0.3806 0.4366 0.4366 0.4366 0.4366 0.4366
Gtop Mpa 0.3251 0.3251 0.3251 0.3806 0.4366 0.4366 0.4366 0.4366 0.4366
Girder

EPC Contractor-M/s Krishna Constructions 199


Design ch-109+720
Design of PSC Girder

Girder Gbottom Mpa -1.589 -1.589 -1.589 -1.436 -1.282 -1.282 -1.282 -1.282 -1.282
Total Stresses (A+B +C+D+E+F+G)
Dtop Mpa -1.589 -1.578 -1.569 -1.418 -1.242 -1.231 -1.083 -0.997 -0.966
Deck Dbottom Mpa 0.1124 0.1208 0.1283 0.2674 0.4247 0.4336 0.5437 0.6082 0.6311
Gtop Mpa 1.3309 1.3278 1.328 2.4717 5.125 5.0776 5.2169 5.5898 5.96
Girder Gbottom Mpa 7.8106 7.8123 7.8104 10.202 14.55 14.602 14.602 14.44 14.218

Max Compressive stress = 14.602 Mpa < 18 Mpa OK


Max Tensile Stress = 1.3278 Mpa >= -3.516 Mpa OK

2) QSP Combination LC-SQ2 : At day 36500


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.7963 0.6113 0.4494 -0.305 -0.181 -0.436 -3.577 -5.253 -5.521
Girder Gbottom Mpa 8.3259 8.5203 8.6899 12.346 17.884 18.153 21.573 23.514 23.931

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder Gbottom Mpa 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.1) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.2) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0107 0.0201 0.1063 0.1964 0.2083 0.3559 0.4423 0.4729
Deck Dbottom Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Gtop Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Girder Gbottom Mpa 0 -0.015 -0.028 -0.173 -0.375 -0.397 -0.679 -0.843 -0.902
F) Stresses due to Live load Load factor = 0
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
G) Stresses due to differential shrinkage Load factor = 1
Dtop Mpa -0.713 -0.713 -0.713 -0.635 -0.477 -0.477 -0.477 -0.477 -0.477
Deck Dbottom Mpa -0.875 -0.875 -0.875 -0.803 -0.652 -0.652 -0.652 -0.652 -0.652
Gtop Mpa 1.1035 1.1035 1.1035 1.1759 1.3266 1.3266 1.3266 1.3266 1.3266
Girder Gbottom Mpa -0.592 -0.592 -0.592 -0.58 -0.511 -0.511 -0.511 -0.511 -0.511
Total Stresses (A+B +C+D+E+F+G)
Dtop Mpa -0.713 -0.703 -0.693 -0.529 -0.28 -0.268 -0.121 -0.034 -0.004
Deck Dbottom Mpa -0.875 -0.867 -0.86 -0.721 -0.506 -0.497 -0.387 -0.322 -0.299
Gtop Mpa 1.8841 1.902 1.9211 3.2062 5.9939 5.9828 6.5561 7.1553 7.5685
Girder Gbottom Mpa 7.7501 7.7291 7.7066 9.2993 12.277 12.288 11.808 11.364 11.062

Max Compressive stress = 12.288 Mpa < 18 Mpa OK


Max Tensile Stress = 1.8841 Mpa >= -3.516 Mpa OK

2.1) QSP Combination LC-SQ2.1 : At day 36500 + temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1

EPC Contractor-M/s Krishna Constructions 200


Design ch-109+720
Design of PSC Girder

A) Stresses due to Prestress force Load factor = 1


Gtop Mpa 0.7963 0.6113 0.4494 -0.305 -0.181 -0.436 -3.577 -5.253 -5.521
Girder Gbottom Mpa 8.3259 8.5203 8.6899 12.346 17.884 18.153 21.573 23.514 23.931

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder Gbottom Mpa 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.1) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.2) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0107 0.0201 0.1063 0.1964 0.2083 0.3559 0.4423 0.4729
Deck Dbottom Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Gtop Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Girder Gbottom Mpa 0 -0.015 -0.028 -0.173 -0.375 -0.397 -0.679 -0.843 -0.902
F) Stresses due to Live load Load factor = 0
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
G) Stresses due to differential shrinkage Load factor = 1
Dtop Mpa -0.713 -0.713 -0.713 -0.635 -0.477 -0.477 -0.477 -0.477 -0.477
Deck Dbottom Mpa -0.875 -0.875 -0.875 -0.803 -0.652 -0.652 -0.652 -0.652 -0.652
Gtop Mpa 1.1035 1.1035 1.1035 1.1759 1.3266 1.3266 1.3266 1.3266 1.3266
Girder Gbottom Mpa -0.592 -0.592 -0.592 -0.58 -0.511 -0.511 -0.511 -0.511 -0.511
H) +ve temperature stresses Load factor = 0.5
Dtop Mpa 2.26 2.26 2.26 2.3498 2.4404 2.4404 2.4404 2.4404 2.4404
Deck Dbottom Mpa -0.66 -0.66 -0.66 -0.598 -0.536 -0.536 -0.536 -0.536 -0.536
Gtop Mpa -0.66 -0.66 -0.66 -0.598 -0.536 -0.536 -0.536 -0.536 -0.536
Girder Gbottom Mpa 1.4029 1.4029 1.4029 1.1743 0.9436 0.9436 0.9436 0.9436 0.9436
Total Stresses (A+B +C+D+E+F+G)
Dtop Mpa 1.5467 1.5574 1.5668 1.8211 2.1603 2.1722 2.3197 2.4062 2.4368
Deck Dbottom Mpa -1.535 -1.527 -1.519 -1.319 -1.041 -1.032 -0.922 -0.858 -0.835
Gtop Mpa 1.2242 1.2422 1.2612 2.6081 5.4583 5.4472 6.0205 6.6197 7.0329
Girder Gbottom Mpa 9.153 9.132 9.1094 10.474 13.221 13.231 12.751 12.308 12.005

Max Compressive stress = 13.231 Mpa < 18 Mpa OK


Max Tensile Stress = 1.2242 Mpa >= -3.516 Mpa OK

2.2) QSP Combination LC-SQ2.2 : At day 36500 - temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.7963 0.6113 0.4494 -0.305 -0.181 -0.436 -3.577 -5.253 -5.521
Girder Gbottom Mpa 8.3259 8.5203 8.6899 12.346 17.884 18.153 21.573 23.514 23.931

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder Gbottom Mpa 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086

EPC Contractor-M/s Krishna Constructions 201


Design ch-109+720
Design of PSC Girder

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.1) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.2) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0107 0.0201 0.1063 0.1964 0.2083 0.3559 0.4423 0.4729
Deck Dbottom Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Gtop Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Girder Gbottom Mpa 0 -0.015 -0.028 -0.173 -0.375 -0.397 -0.679 -0.843 -0.902
F) Stresses due to Live load Load factor = 0
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
G) Stresses due to differential shrinkage Load factor = 1
Dtop Mpa -0.713 -0.713 -0.713 -0.635 -0.477 -0.477 -0.477 -0.477 -0.477
Deck Dbottom Mpa -0.875 -0.875 -0.875 -0.803 -0.652 -0.652 -0.652 -0.652 -0.652
Gtop Mpa 1.1035 1.1035 1.1035 1.1759 1.3266 1.3266 1.3266 1.3266 1.3266
Girder Gbottom Mpa -0.592 -0.592 -0.592 -0.58 -0.511 -0.511 -0.511 -0.511 -0.511
H) -ve temperature stresses Load factor = 0.5
Dtop Mpa -1.416 -1.416 -1.416 -1.37 -1.323 -1.323 -1.323 -1.323 -1.323
Deck Dbottom Mpa 0.3251 0.3251 0.3251 0.3806 0.4366 0.4366 0.4366 0.4366 0.4366
Gtop Mpa 0.3251 0.3251 0.3251 0.3806 0.4366 0.4366 0.4366 0.4366 0.4366
Girder Gbottom Mpa -1.589 -1.589 -1.589 -1.436 -1.282 -1.282 -1.282 -1.282 -1.282
Total Stresses (A+B +C+D+E+F+G)
Dtop Mpa -2.129 -2.118 -2.109 -1.898 -1.603 -1.591 -1.444 -1.357 -1.327
Deck Dbottom Mpa -0.55 -0.542 -0.534 -0.34 -0.069 -0.06 0.0499 0.1144 0.1372
Gtop Mpa 2.2092 2.2271 2.2462 3.5868 6.4305 6.4195 6.9927 7.592 8.0051
Girder Gbottom Mpa 6.1607 6.1397 6.1171 7.8629 10.995 11.006 10.526 10.082 9.7796

Max Compressive stress = 11.006 Mpa < 18 Mpa OK


Max Tensile Stress = 2.2092 Mpa >= -3.516 Mpa OK

SUMMARY FOR SLS QUASI PERMANENT LOAD COMBINATION


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
1) QSP Combination LC-SQ1 : At day 92 Structure open to LL
Total Stresses (A+B)
Gtop Mpa 1.0058 1.0027 1.0029 2.0911 4.6884 4.641 4.7802 5.1531 5.5234
Girder Gbottom Mpa 9.4001 9.4017 9.3998 11.638 15.832 15.884 15.884 15.722 15.5
2) QSP Combination LC-SQ2 : At day 36500
Total Stresses (A+B)
Gtop Mpa 1.8841 1.902 1.9211 3.2062 5.9939 5.9828 6.5561 7.1553 7.5685
Girder Gbottom Mpa 7.7501 7.7291 7.7066 9.2993 12.277 12.288 11.808 11.364 11.062
1.1) QSP Combination LC-SQ1.1 : At day 92 Structure open to LL + temperature stresses
Total Stresses (A+B)
Gtop Mpa 0.3459 0.3428 0.343 1.4931 4.1527 4.1054 4.2446 4.6175 4.9878
Girder Gbottom Mpa 10.803 10.805 10.803 12.812 16.776 16.828 16.828 16.666 16.443

EPC Contractor-M/s Krishna Constructions 202


Design ch-109+720
Design of PSC Girder

2.1) QSP Combination LC-SQ2.1 : At day 36500 + temperature stresses


Total Stresses (A+B)
Gtop Mpa 1.2242 1.2422 1.2612 2.6081 5.4583 5.4472 6.0205 6.6197 7.0329
Girder Gbottom Mpa 9.153 9.132 9.1094 10.474 13.221 13.231 12.751 12.308 12.005
1.2) QSP Combination LC-SQ1.2 : At day 92 Structure open to LL - temperature stresses
Total Stresses (A+B)
Gtop Mpa 1.3309 1.3278 1.328 2.4717 5.125 5.0776 5.2169 5.5898 5.96
Girder Gbottom Mpa 7.8106 7.8123 7.8104 10.202 14.55 14.602 14.602 14.44 14.218
2.2) QSP Combination LC-SQ2.2 : At day 36500 - temperature stresses
Total Stresses (A+B)
Gtop Mpa 2.2092 2.2271 2.2462 3.5868 6.4305 6.4195 6.9927 7.592 8.0051
Girder Gbottom Mpa 6.1607 6.1397 6.1171 7.8629 10.995 11.006 10.526 10.082 9.7796

EPC Contractor-M/s Krishna Constructions 203


Design ch-109+720
Design of PSC Girder

CHECK FOR STRESSES : PRESTRESS WITH INFERIOR LOAD COMBINATION

SLS STRESS CHECK : RARE COMBINATION INFERIOR


A) INNER GIRDER SUMMARY OF LOADS
BENDING MOMENT SUMMARY
Section At unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
Precast Beam Tm -0 -0.054 -0.73 8.6895 16.778 84.646 142.08 150.3 253.22 314.97 335.55
Deck Inner Girder Tm -0.043 -0.079 -0.473 5.0827 10.351 61.662 106.55 110.76 198.45 253.61 267.86
Transfer brg. Tm 0 0 0 0 0 0 0 0 0 0 0
SIDL Tm 0 0 0 0 0 0 0 0 0 0 0
Surfacing Tm 0 0 0 1.633 3.079 15.582 27.288 28.941 49.434 61.442 65.692
Wind Load T 0 0 0 1.608 3.031 15.343 26.868 28.495 48.674 60.497 64.681
Live Load (Without SV Loading) Tm 0 0 0 16.179 26.929 114.16 181.79 191.85 256.36 322.14 330.85
Live Load (With SV Loading) Tm 0 0 0 7.128 14.513 79.248 141.54 150.99 267 348.51 360.44

SECTION PROPERTIES
Sections unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Section at m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
Properties of Precast Section
Area m2 1.9297 1.9297 1.9297 1.9297 1.9297 1.4394 0.9447 0.9447 0.9447 0.9447 0.9447
I gross m4 0.872 0.872 0.872 0.872 0.872 0.7401 0.6069 0.6069 0.6069 0.6069 0.6069
yb m 1.1677 1.1677 1.1677 1.1677 1.1677 1.16 1.1524 1.1524 1.1524 1.1524 1.1524
yt m 1.1323 1.1323 1.1323 1.1323 1.1323 1.14 1.1476 1.1476 1.1476 1.1476 1.1476
Properties of Composite Section
Area m2 2.5546 2.5546 2.5546 2.5546 2.5546 2.0643 1.5696 1.5696 1.5696 1.5696 1.5696
I gross m4 1.6031 1.6031 1.6031 1.6031 1.6031 1.4046 1.2043 1.2043 1.2043 1.2043 1.2043
yb m 1.4715 1.4715 1.4715 1.4715 1.4715 1.5619 1.653 1.653 1.653 1.653 1.653
yt m 1.0485 1.0485 1.0485 1.0485 1.0485 0.9581 0.867 0.867 0.867 0.867 0.867
Gtop m 0.8285 0.8285 0.8285 0.8285 0.8285 0.7381 0.647 0.647 0.647 0.647 0.647

STRESSES DUE TO ACTION OF LOADS :


Section At unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
Precast Beam
Gtop Mpa 0 -7E-04 -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0 0.0007 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

Deck Inner Girder


Gtop Mpa -6E-04 -0.001 -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder Gbottom Mpa 0.0006 0.0011 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086

Transfer brg.
Dtop Mpa 0 0 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0 0 0
Stresses Girder
At Gbottom Mpa 0 0 0 0 0 0 0 0 0 0 0

SIDL
Dtop Mpa 0 0 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0 0 0
Stresses Girder
At Gbottom Mpa 0 0 0 0 0 0 0 0 0 0 0

Section At unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
Surfacing
Dtop Mpa 0 0 0 0.0107 0.0201 0.1063 0.1964 0.2083 0.3559 0.4423 0.4729
Deck Dbottom Mpa 0 0 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Gtop Mpa 0 0 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Stresses Girder
At Gbottom Mpa 0 0 0 -0.015 -0.028 -0.173 -0.375 -0.397 -0.679 -0.843 -0.902

EPC Contractor-M/s Krishna Constructions 204


Design ch-109+720
Design of PSC Girder

Live Load (Without SV Loading)


Dtop Mpa 0 0 0 0.1058 0.1761 0.7787 1.3087 1.3811 1.8455 2.319 2.3818
Deck Dbottom Mpa 0 0 0 0.0836 0.1392 0.5999 0.9766 1.0306 1.3772 1.7306 1.7774
Gtop Mpa 0 0 0 0.0836 0.1392 0.5999 0.9766 1.0306 1.3772 1.7306 1.7774
Stresses Girder
At Gbottom Mpa 0 0 0 -0.149 -0.247 -1.269 -2.495 -2.633 -3.519 -4.422 -4.541

Live Load (With SV Loading)


Dtop Mpa 0 0 0 0.0466 0.0949 0.5406 1.0189 1.0869 1.9221 2.5089 2.5948
Deck Dbottom Mpa 0 0 0 0.0368 0.075 0.4165 0.7604 0.8111 1.4343 1.8722 1.9363
Gtop Mpa 0 0 0 0.0368 0.075 0.4165 0.7604 0.8111 1.4343 1.8722 1.9363
Stresses Girder
At Gbottom Mpa 0 0 0 -0.065 -0.133 -0.881 -1.943 -2.073 -3.665 -4.784 -4.948

Wind Load
Dtop Mpa 0 0 0 0.0105 0.0198 0.1047 0.1934 0.2051 0.3504 0.4355 0.4656
Deck Dbottom Mpa 0 0 0 0.0083 0.0157 0.0806 0.1443 0.1531 0.2615 0.325 0.3475
Gtop Mpa 0 0 0 0.0083 0.0157 0.0806 0.1443 0.1531 0.2615 0.325 0.3475
Stresses Girder
At Gbottom Mpa 0 0 0 -0.015 -0.028 -0.171 -0.369 -0.391 -0.668 -0.83 -0.888

STRESSES DUE TO DIFFERENTIAL SHRINKAGE :


At day 63
Dtop Mpa -0.182 -0.182 -0.182 -0.182 -0.182 -0.162 -0.122 -0.122 -0.122 -0.122 -0.122
Deck Dbottom Mpa -0.224 -0.224 -0.224 -0.224 -0.224 -0.205 -0.167 -0.167 -0.167 -0.167 -0.167
Gtop Mpa 0.2822 0.2822 0.2822 0.2822 0.2822 0.3008 0.3393 0.3393 0.3393 0.3393 0.3393
Stresses Girder
At Gbottom Mpa -0.151 -0.151 -0.151 -0.151 -0.151 -0.148 -0.131 -0.131 -0.131 -0.131 -0.131

At day 64
Dtop Mpa -0.182 -0.182 -0.182 -0.182 -0.182 -0.162 -0.122 -0.122 -0.122 -0.122 -0.122
Deck Dbottom Mpa -0.224 -0.224 -0.224 -0.224 -0.224 -0.205 -0.167 -0.167 -0.167 -0.167 -0.167
Gtop Mpa 0.2821 0.2821 0.2821 0.2821 0.2821 0.3007 0.3392 0.3392 0.3392 0.3392 0.3392
Stresses Girder
At Gbottom Mpa -0.151 -0.151 -0.151 -0.151 -0.151 -0.148 -0.131 -0.131 -0.131 -0.131 -0.131

At day 92
Dtop Mpa -0.173 -0.173 -0.173 -0.173 -0.173 -0.154 -0.116 -0.116 -0.116 -0.116 -0.116
Deck Dbottom Mpa -0.213 -0.213 -0.213 -0.213 -0.213 -0.195 -0.158 -0.158 -0.158 -0.158 -0.158
Gtop Mpa 0.2681 0.2681 0.2681 0.2681 0.2681 0.2857 0.3223 0.3223 0.3223 0.3223 0.3223
Stresses Girder
At Gbottom Mpa -0.144 -0.144 -0.144 -0.144 -0.144 -0.141 -0.124 -0.124 -0.124 -0.124 -0.124

At day 36500
Dtop Mpa -0.713 -0.713 -0.713 -0.713 -0.713 -0.635 -0.477 -0.477 -0.477 -0.477 -0.477
Deck Dbottom Mpa -0.875 -0.875 -0.875 -0.875 -0.875 -0.803 -0.652 -0.652 -0.652 -0.652 -0.652
Gtop Mpa 1.1035 1.1035 1.1035 1.1035 1.1035 1.1759 1.3266 1.3266 1.3266 1.3266 1.3266
Stresses Girder
At Gbottom Mpa -0.592 -0.592 -0.592 -0.592 -0.592 -0.58 -0.511 -0.511 -0.511 -0.511 -0.511

STRESSES DUE TO +VE TEMPERATURE STRESSES :


Section At unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
Dtop Mpa 4.52 4.52 4.52 4.6996 4.8808 4.8808 4.8808 4.8808 4.8808
Deck Dbottom Mpa -1.32 -1.32 -1.32 -1.196 -1.071 -1.071 -1.071 -1.071 -1.071
Gtop Mpa -1.32 -1.32 -1.32 -1.196 -1.071 -1.071 -1.071 -1.071 -1.071
Stresses Girder
At Gbottom Mpa 2.8058 2.8058 2.8058 2.3486 1.8872 1.8872 1.8872 1.8872 1.8872
STRESSES DUE TO -VE TEMPERATURE STRESSES :
Dtop Mpa -2.831 -2.831 -2.831 -2.739 -2.646 -2.646 -2.646 -2.646 -2.646
Deck Dbottom Mpa 0.6502 0.6502 0.6502 0.7612 0.8733 0.8733 0.8733 0.8733 0.8733
Gtop Mpa 0.6502 0.6502 0.6502 0.7612 0.8733 0.8733 0.8733 0.8733 0.8733
Stresses Girder
At Gbottom Mpa -3.179 -3.179 -3.179 -2.873 -2.564 -2.564 -2.564 -2.564 -2.564

EPC Contractor-M/s Krishna Constructions 205


Design ch-109+720
Design of PSC Girder

STRESSES AT DIFFERENT STAGES DUE TO PRE-STRESSING FORCES :


Load factor Superior load factor = 0.9
Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
Gtop At day 14 Mpa -2.653 -2.706 -2.753 -3.26 -3.34 -3.416 -4.354 -4.863 -4.972
Girder Gbottom Mpa 8.4045 8.4616 8.5118 10.908 14.897 14.983 16.055 16.697 16.923

Gtop 14 To day 28 Mpa -2.54 -2.59 -2.634 -3.104 -3.151 -3.222 -4.106 -4.585 -4.686
Girder Gbottom Mpa 8.0437 8.0982 8.1461 10.385 14.052 14.132 15.141 15.744 15.948

Gtop At day 28 Mpa 0.6638 0.4882 0.3338 -0.443 -0.432 -0.684 -3.768 -5.401 -5.664
Girder Gbottom Mpa 8.0633 8.2486 8.4114 12.144 18.142 18.412 21.773 23.677 24.087

Gtop 28 To day 35 Mpa 0.6125 0.4407 0.2898 -0.469 -0.446 -0.691 -3.682 -5.259 -5.513
Girder Gbottom Mpa 7.9968 8.1774 8.3359 11.977 17.779 18.038 21.244 23.042 23.432

Girder Gtop 35 To day 63 Mpa 0.613 0.4433 0.2943 -0.449 -0.417 -0.657 -3.606 -5.171 -5.425
Gbottom Mpa 7.8696 8.0484 8.2051 11.774 17.428 17.684 20.886 22.702 23.103

Girder Gtop 63 To day 64 Mpa 0.6129 0.4432 0.2943 -0.449 -0.416 -0.656 -3.604 -5.168 -5.423
Gbottom Mpa 7.8666 8.0453 8.2019 11.769 17.419 17.675 20.875 22.691 23.092

Girder Gtop 64 To day 92 Mpa 0.6164 0.4478 0.3 -0.434 -0.394 -0.633 -3.558 -5.114 -5.369
Gbottom Mpa 7.7954 7.9731 8.1287 11.655 17.224 17.478 20.67 22.488 22.895

Gtop 92 To day 36500 Mpa 0.6515 0.5002 0.3677 -0.25 -0.148 -0.357 -2.927 -4.298 -4.517
Girder Gbottom Mpa 6.8121 6.9712 7.11 10.101 14.632 14.852 17.651 19.239 19.58

RARE LOAD COMBINATIONS :


1) Rare Combination LC-SR1 : At the time of 1st stage prestress, just after ES loss of Stage -I cables
Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop At day 14 Mpa -2.653 -2.706 -2.753 -3.26 -3.34 -3.416 -4.354 -4.863 -4.972
Girder Gbottom Mpa 8.4045 8.4616 8.5118 10.908 14.897 14.983 16.055 16.697 16.923

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

Total Stresses (A+B)


Gtop Mpa -2.663 -2.593 -2.535 -1.956 -0.653 -0.574 0.4343 1.0932 1.3729
Girder Gbottom Mpa 8.4143 8.3453 8.2871 9.5813 12.2 12.129 11.247 10.717 10.552

Max Compressive stress = 12.2 Mpa < 24 Mpa OK


Max Tensile Stress = -2.663 Mpa >= -3.516 Mpa OK

2) Rare Combination LC-SR2 : At day 28 Just before II Stage prestressing


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop At day 0 Mpa -2.54 -2.59 -2.634 -3.104 -3.151 -3.222 -4.106 -4.585 -4.686
Girder Gbottom Mpa 8.0437 8.0982 8.1461 10.385 14.052 14.132 15.141 15.744 15.948

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

Total Stresses (A+B+C)

EPC Contractor-M/s Krishna Constructions 206


Design ch-109+720
Design of PSC Girder

Gtop Mpa -2.549 -2.477 -2.416 -1.8 -0.464 -0.38 0.6822 1.3707 1.6595
Girder Gbottom Mpa 8.0535 7.9819 7.9214 9.0586 11.354 11.278 10.333 9.764 9.5766

Max Compressive stress = 11.354 Mpa < 24 Mpa OK


Max Tensile Stress = -2.549 Mpa >= -3.516 Mpa OK

3) Rare Combination LC-SR3 : At day 28 Just after II Stage prestressing after ES


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.6638 0.4882 0.3338 -0.443 -0.432 -0.684 -3.768 -5.401 -5.664
Girder Gbottom Mpa 8.0633 8.2486 8.4114 12.144 18.142 18.412 21.773 23.677 24.087

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

Total Stresses (A+B)


Gtop Mpa 0.6544 0.601 0.5517 0.8605 2.2543 2.1579 1.0205 0.555 0.6815
Girder Gbottom Mpa 8.073 8.1323 8.1868 10.817 15.444 15.558 16.965 17.697 17.715

Max Compressive stress = 17.715 Mpa < 24 Mpa OK


Max Tensile Stress = 0.5517 Mpa >= -3.516 Mpa OK

4) Rare Combination LC-SR4 : At day 35 At the time of casting of deck slab


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.6125 0.4407 0.2898 -0.469 -0.446 -0.691 -3.682 -5.259 -5.513
Girder Gbottom Mpa 7.9968 8.1774 8.3359 11.977 17.779 18.038 21.244 23.042 23.432

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder Gbottom Mpa 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086
Total Stresses (A+B +C)
Gtop Mpa 0.5969 0.6196 0.6421 1.7848 4.2552 4.2453 4.8587 5.4924 5.8974
Girder Gbottom Mpa 8.0129 7.9929 7.9727 9.6841 13.059 13.081 12.668 12.247 11.975

Max Compressive stress = 13.081 Mpa < 24 Mpa OK


Max Tensile Stress = 0.5969 Mpa >= -3.516 Mpa OK

5) Rare Combination LC-SR5 : At day 63 At the time of transfer over permanent bearings
Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.613 0.4433 0.2943 -0.449 -0.417 -0.657 -3.606 -5.171 -5.425
Girder Gbottom Mpa 7.8696 8.0484 8.2051 11.774 17.428 17.684 20.886 22.702 23.103

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

EPC Contractor-M/s Krishna Constructions 207


Design ch-109+720
Design of PSC Girder

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder Gbottom Mpa 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to differencial shrinkage Load factor = 1
Dtop Mpa -0.182 -0.182 -0.182 -0.162 -0.122 -0.122 -0.122 -0.122 -0.122
Deck Dbottom Mpa -0.224 -0.224 -0.224 -0.205 -0.167 -0.167 -0.167 -0.167 -0.167
Gtop Mpa 0.2822 0.2822 0.2822 0.3008 0.3393 0.3393 0.3393 0.3393 0.3393
Girder Gbottom Mpa -0.151 -0.151 -0.151 -0.148 -0.131 -0.131 -0.131 -0.131 -0.131
Total Stresses (A+B +C+D+E)
Dtop Mpa -0.182 -0.182 -0.182 -0.162 -0.122 -0.122 -0.122 -0.122 -0.122
Deck Dbottom Mpa -0.224 -0.224 -0.224 -0.205 -0.167 -0.167 -0.167 -0.167 -0.167
Gtop Mpa 0.8796 0.9043 0.9288 2.1054 4.6242 4.6186 5.2741 5.92 6.3241
Girder Gbottom Mpa 7.7343 7.7126 7.6904 9.3321 12.577 12.597 12.179 11.776 11.516

Max Compressive stress = 12.597 Mpa < 24 Mpa OK


Max Tensile Stress = 0.8796 Mpa >= -3.516 Mpa OK

6) Rare Combination LC-SR6 : At day 64 At the time of placing of SIDL


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.6129 0.4432 0.2943 -0.449 -0.416 -0.656 -3.604 -5.168 -5.423
Girder Gbottom Mpa 7.8666 8.0453 8.2019 11.769 17.419 17.675 20.875 22.691 23.092

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder Gbottom Mpa 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.1) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.2) Stresses due to placement of SurfacingLoad factor = 1
Dtop Mpa 0 0.0107 0.0201 0.1063 0.1964 0.2083 0.3559 0.4423 0.4729
Deck Dbottom Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Gtop Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Girder Gbottom Mpa 0 -0.015 -0.028 -0.173 -0.375 -0.397 -0.679 -0.843 -0.902

F) Stresses due to Differential shrinkage Load factor = 1


Dtop Mpa -0.182 -0.182 -0.182 -0.162 -0.122 -0.122 -0.122 -0.122 -0.122
Deck Dbottom Mpa -0.224 -0.224 -0.224 -0.205 -0.167 -0.167 -0.167 -0.167 -0.167
Gtop Mpa 0.2821 0.2821 0.2821 0.3007 0.3392 0.3392 0.3392 0.3392 0.3392
Girder Gbottom Mpa -0.151 -0.151 -0.151 -0.148 -0.131 -0.131 -0.131 -0.131 -0.131
G) Stresses due to wind Load factor = 0.6
Dtop Mpa 0 0.0063 0.0119 0.0628 0.1161 0.1231 0.2102 0.2613 0.2794
Deck

EPC Contractor-M/s Krishna Constructions 208


Design ch-109+720
Design of PSC Girder

Deck Dbottom Mpa 0 0.005 0.0094 0.0484 0.0866 0.0918 0.1569 0.195 0.2085
Gtop Mpa 0 0.005 0.0094 0.0484 0.0866 0.0918 0.1569 0.195 0.2085
Girder Gbottom Mpa 0 -0.009 -0.017 -0.102 -0.221 -0.235 -0.401 -0.498 -0.533
Total Stresses (A+B +C+D+E+F)
Dtop Mpa -0.182 -0.172 -0.162 -0.056 0.0746 0.0865 0.234 0.3205 0.3511
Deck Dbottom Mpa -0.224 -0.215 -0.208 -0.123 -0.02 -0.011 0.0988 0.1633 0.1861
Gtop Mpa 0.8794 0.9126 0.9447 2.1877 4.7714 4.7749 5.5417 6.2527 6.6798
Girder Gbottom Mpa 7.7314 7.6946 7.6591 9.1537 12.193 12.19 11.49 10.921 10.603
Total Stresses (A+B +C+D+E+F+G) wind downward
Dtop Mpa -0.182 -0.165 -0.15 0.0067 0.1907 0.2096 0.4443 0.5818 0.6304
Deck Dbottom Mpa -0.224 -0.21 -0.199 -0.075 0.0664 0.0805 0.2557 0.3583 0.3946
Gtop Mpa 0.8794 0.9176 0.9541 2.236 4.858 4.8667 5.6986 6.4477 6.8883
Girder Gbottom Mpa 7.7314 7.6857 7.6424 9.0514 11.972 11.956 11.089 10.423 10.07
Total Stresses (A+B +C+D+E+F+G) wind upward
Dtop Mpa -0.182 -0.178 -0.174 -0.119 -0.041 -0.037 0.0238 0.0592 0.0717
Deck Dbottom Mpa -0.224 -0.22 -0.217 -0.172 -0.107 -0.103 -0.058 -0.032 -0.022
Gtop Mpa 0.8794 0.9076 0.9353 2.1393 4.6848 4.683 5.3848 6.0577 6.4713
Girder Gbottom Mpa 7.7314 7.7034 7.6758 9.2561 12.414 12.425 11.891 11.419 11.136

Max CompressiveMaxstress
Compressive stress = 12.193 Mpa < 24 Mpa OK
Max Tensile Stress = 0.8794 Mpa >= -3.516 Mpa OK

Max Compressive stress (wind downward) = 11.972 Mpa < 24 Mpa OK


Max Tensile Stress (wind downward) = 0.8794 Mpa >= -3.516 Mpa OK

Max Compressive stress (wind upward) = 12.425 Mpa < 24 Mpa OK


Max Tensile Stress (wind upward) = 0.8794 Mpa >= -3.516 Mpa OK

7) Rare Combination LC-SR7 : At day 92 Structure open to LL


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.6164 0.4478 0.3 -0.434 -0.394 -0.633 -3.558 -5.114 -5.369
Girder Gbottom Mpa 7.7954 7.9731 8.1287 11.655 17.224 17.478 20.67 22.488 22.895

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder Gbottom Mpa 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0107 0.0201 0.1063 0.1964 0.2083 0.3559 0.4423 0.4729
Deck Dbottom Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Gtop Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Girder Gbottom Mpa 0 -0.015 -0.028 -0.173 -0.375 -0.397 -0.679 -0.843 -0.902
F) Stresses due to Live load (Without SV) Load factor = 1
Dtop Mpa 0 0.1058 0.1761 0.7787 1.3087 1.3811 1.8455 2.319 2.3818
Deck

EPC Contractor-M/s Krishna Constructions 209


Design ch-109+720
Design of PSC Girder

Deck Dbottom Mpa 0 0.0836 0.1392 0.5999 0.9766 1.0306 1.3772 1.7306 1.7774
Gtop Mpa 0 0.0836 0.1392 0.5999 0.9766 1.0306 1.3772 1.7306 1.7774
Girder Gbottom Mpa 0 -0.149 -0.247 -1.269 -2.495 -2.633 -3.519 -4.422 -4.541
F.1) Stresses due to Live load (With SV) Load factor = 1
Dtop Mpa 0 0.0466 0.0949 0.5406 1.0189 1.0869 1.9221 2.5089 2.5948
Deck Dbottom Mpa 0 0.0368 0.075 0.4165 0.7604 0.8111 1.4343 1.8722 1.9363
Gtop Mpa 0 0.0368 0.075 0.4165 0.7604 0.8111 1.4343 1.8722 1.9363
Girder Gbottom Mpa 0 -0.065 -0.133 -0.881 -1.943 -2.073 -3.665 -4.784 -4.948
G) Stresses due to differential shrinkage Load factor = 1
Dtop Mpa -0.173 -0.173 -0.173 -0.154 -0.116 -0.116 -0.116 -0.116 -0.116
Deck Dbottom Mpa -0.213 -0.213 -0.213 -0.195 -0.158 -0.158 -0.158 -0.158 -0.158
Gtop Mpa 0.2681 0.2681 0.2681 0.2857 0.3223 0.3223 0.3223 0.3223 0.3223
Girder Gbottom Mpa -0.144 -0.144 -0.144 -0.141 -0.124 -0.124 -0.124 -0.124 -0.124
G) Stresses due to wind Load factor = 0.6
Dtop Mpa 0 0.0063 0.0119 0.0628 0.1161 0.1231 0.2102 0.2613 0.2794
Deck Dbottom Mpa 0 0.005 0.0094 0.0484 0.0866 0.0918 0.1569 0.195 0.2085
Gtop Mpa 0 0.005 0.0094 0.0484 0.0866 0.0918 0.1569 0.195 0.2085
Girder Gbottom Mpa 0 -0.009 -0.017 -0.102 -0.221 -0.235 -0.401 -0.498 -0.533
Total Stresses (A+B +C+D+E+F+G) (Without SV Loading)
Dtop Mpa -0.173 -0.057 0.023 0.7307 1.3894 1.4736 2.0856 2.6456 2.7389
Deck Dbottom Mpa -0.213 -0.121 -0.058 0.4867 0.9647 1.0276 1.4843 1.9021 1.9718
Gtop Mpa 0.8689 0.9868 1.0755 2.7874 5.7526 5.8122 6.9481 8.0202 8.4939
Girder Gbottom Mpa 7.6677 7.4814 7.3462 7.7784 9.5092 9.3668 7.772 6.3032 5.8706
Total Stresses (A+B +C+D+E+F+G) (With SV Loading)
Dtop Mpa -0.173 -0.116 -0.058 0.4926 1.0996 1.1795 2.1622 2.8354 2.9519
Deck Dbottom Mpa -0.213 -0.167 -0.122 0.3032 0.7485 0.8081 1.5414 2.0438 2.1307
Gtop Mpa 0.8689 0.9401 1.0113 2.604 5.5364 5.5927 7.0052 8.1619 8.6528
Girder Gbottom Mpa 7.6677 7.5645 7.4602 8.1666 10.062 9.9277 7.626 5.9412 5.4644
Total Stresses (A+B +C+D+E+F+G) wind downward
Dtop Mpa -0.173 -0.051 0.0348 0.7935 1.5054 1.5967 2.2958 2.9069 3.0183
Deck Dbottom Mpa -0.213 -0.116 -0.048 0.5351 1.0513 1.1194 1.6411 2.0971 2.1803
Gtop Mpa 0.8689 0.9918 1.0849 2.8358 5.8392 5.9041 7.105 8.2152 8.7023
Girder Gbottom Mpa 7.6677 7.4725 7.3295 7.676 9.2879 9.1322 7.3711 5.8049 5.3379
Total Stresses (A+B +C+D+E+F+G) wind upward
Dtop Mpa -0.173 -0.063 0.0111 0.6679 1.2733 1.3506 1.8754 2.3843 2.4595
Deck Dbottom Mpa -0.213 -0.126 -0.067 0.4383 0.8781 0.9357 1.3274 1.7071 1.7633
Gtop Mpa 0.8689 0.9818 1.0661 2.739 5.666 5.7204 6.7912 7.8252 8.2854
Girder Gbottom Mpa 7.6677 7.4902 7.3629 7.8808 9.7304 9.6015 8.1729 6.8014 6.4033
Max Compressive stress = 10.062 Mpa < 24 Mpa OK
Max Tensile Stress = 0.8689 Mpa >= -3.516 Mpa OK
Max Compressive stress (wind downward) = 9.2879 Mpa < 24 Mpa OK
Max Tensile Stress (wind downward) = 0.8689 Mpa >= -3.516 Mpa OK
Max Compressive stress (wind upward) = 9.7304 Mpa < 24 Mpa OK
Max Tensile Stress (wind upward) = 0.8689 Mpa >= -3.516 Mpa OK

7.1) Rare Combination LC-SR7.1 : At day 92 Structure open to LL + temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.6164 0.4478 0.3 -0.434 -0.394 -0.633 -3.558 -5.114 -5.369
Girder Gbottom Mpa 7.7954 7.9731 8.1287 11.655 17.224 17.478 20.67 22.488 22.895

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder Gbottom Mpa 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086

EPC Contractor-M/s Krishna Constructions 210


Design ch-109+720
Design of PSC Girder

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0107 0.0201 0.1063 0.1964 0.2083 0.3559 0.4423 0.4729
Deck Dbottom Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Gtop Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Girder Gbottom Mpa 0 -0.015 -0.028 -0.173 -0.375 -0.397 -0.679 -0.843 -0.902
F) Stresses due to Live load (Without SV) Load factor = 1
Dtop Mpa 0 0.1058 0.1761 0.7787 1.3087 1.3811 1.8455 2.319 2.3818
Deck Dbottom Mpa 0 0.0836 0.1392 0.5999 0.9766 1.0306 1.3772 1.7306 1.7774
Gtop Mpa 0 0.0836 0.1392 0.5999 0.9766 1.0306 1.3772 1.7306 1.7774
Girder Gbottom Mpa 0 -0.149 -0.247 -1.269 -2.495 -2.633 -3.519 -4.422 -4.541
F.1) Stresses due to Live load (With SV) Load factor = 1
Dtop Mpa 0 0.0466 0.0949 0.5406 1.0189 1.0869 1.9221 2.5089 2.5948
Deck Dbottom Mpa 0 0.0368 0.075 0.4165 0.7604 0.8111 1.4343 1.8722 1.9363
Gtop Mpa 0 0.0368 0.075 0.4165 0.7604 0.8111 1.4343 1.8722 1.9363
Girder Gbottom Mpa 0 -0.065 -0.133 -0.881 -1.943 -2.073 -3.665 -4.784 -4.948
G) Stresses due to differential shrinkage Load factor = 1
Dtop Mpa -0.173 -0.173 -0.173 -0.154 -0.116 -0.116 -0.116 -0.116 -0.116
Deck Dbottom Mpa -0.213 -0.213 -0.213 -0.195 -0.158 -0.158 -0.158 -0.158 -0.158
Gtop Mpa 0.2681 0.2681 0.2681 0.2857 0.3223 0.3223 0.3223 0.3223 0.3223
Girder Gbottom Mpa -0.144 -0.144 -0.144 -0.141 -0.124 -0.124 -0.124 -0.124 -0.124

H) +ve temperature stresses Load factor = 0.6


Dtop Mpa 2.712 2.712 2.712 2.8197 2.9285 2.9285 2.9285 2.9285 2.9285
Deck Dbottom Mpa -0.792 -0.792 -0.792 -0.718 -0.643 -0.643 -0.643 -0.643 -0.643
Gtop Mpa -0.792 -0.792 -0.792 -0.718 -0.643 -0.643 -0.643 -0.643 -0.643
Girder Gbottom Mpa 1.6835 1.6835 1.6835 1.4091 1.1323 1.1323 1.1323 1.1323 1.1323
Total Stresses (A+B +C+D+E+F+G+H) (Without SV)
Dtop Mpa 2.5387 2.6552 2.7349 3.5504 4.3178 4.4021 5.0141 5.5741 5.6674
Deck Dbottom Mpa -1.005 -0.913 -0.85 -0.231 0.322 0.3849 0.8415 1.2594 1.329
Gtop Mpa 0.077 0.1949 0.2836 2.0698 5.1099 5.1695 6.3054 7.3775 7.8511
Girder Gbottom Mpa 9.3512 9.1648 9.0297 9.1875 10.641 10.499 8.9043 7.4355 7.0029
Total Stresses (A+B +C+D+E+F+G+H) (With SV Loading)
Dtop Mpa -0.173 -0.116 -0.058 0.4926 1.0996 1.1795 2.1622 2.8354 2.9519
Deck Dbottom Mpa -0.213 -0.167 -0.122 0.3032 0.7485 0.8081 1.5414 2.0438 2.1307
Gtop Mpa 0.8689 0.9401 1.0113 2.604 5.5364 5.5927 7.0052 8.1619 8.6528
Girder Gbottom Mpa 7.6677 7.5645 7.4602 8.1666 10.062 9.9277 7.626 5.9412 5.4644

Max Compressive stress = 10.641 Mpa < 24 Mpa OK


Max Tensile Stress = 0.077 Mpa >= -3.516 Mpa OK

7.2) Rare Combination LC-SR7.2 : At day 92 Structure open to LL - temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.6164 0.4478 0.3 -0.434 -0.394 -0.633 -3.558 -5.114 -5.369
Girder

EPC Contractor-M/s Krishna Constructions 211


Design ch-109+720
Design of PSC Girder

Girder Gbottom Mpa 7.7954 7.9731 8.1287 11.655 17.224 17.478 20.67 22.488 22.895

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder Gbottom Mpa 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0107 0.0201 0.1063 0.1964 0.2083 0.3559 0.4423 0.4729
Deck Dbottom Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Gtop Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Girder Gbottom Mpa 0 -0.015 -0.028 -0.173 -0.375 -0.397 -0.679 -0.843 -0.902
F) Stresses due to Live load (Without SV) Load factor = 1
Dtop Mpa 0 0.1058 0.1761 0.7787 1.3087 1.3811 1.8455 2.319 2.3818
Deck Dbottom Mpa 0 0.0836 0.1392 0.5999 0.9766 1.0306 1.3772 1.7306 1.7774
Gtop Mpa 0 0.0836 0.1392 0.5999 0.9766 1.0306 1.3772 1.7306 1.7774
Girder Gbottom Mpa 0 -0.149 -0.247 -1.269 -2.495 -2.633 -3.519 -4.422 -4.541
F.1) Stresses due to Live load (With SV) Load factor = 1
Dtop Mpa 0 0.0466 0.0949 0.5406 1.0189 1.0869 1.9221 2.5089 2.5948
Deck Dbottom Mpa 0 0.0368 0.075 0.4165 0.7604 0.8111 1.4343 1.8722 1.9363
Gtop Mpa 0 0.0368 0.075 0.4165 0.7604 0.8111 1.4343 1.8722 1.9363
Girder Gbottom Mpa 0 -0.065 -0.133 -0.881 -1.943 -2.073 -3.665 -4.784 -4.948

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.173 -0.173 -0.173 -0.154 -0.116 -0.116 -0.116 -0.116 -0.116
Deck Dbottom Mpa -0.213 -0.213 -0.213 -0.195 -0.158 -0.158 -0.158 -0.158 -0.158
Gtop Mpa 0.2681 0.2681 0.2681 0.2857 0.3223 0.3223 0.3223 0.3223 0.3223
Girder Gbottom Mpa -0.144 -0.144 -0.144 -0.141 -0.124 -0.124 -0.124 -0.124 -0.124
H) -ve temperature stresses Load factor = 0.6
Dtop Mpa -1.699 -1.699 -1.699 -1.643 -1.588 -1.588 -1.588 -1.588 -1.588
Deck Dbottom Mpa 0.3901 0.3901 0.3901 0.4567 0.524 0.524 0.524 0.524 0.524
Gtop Mpa 0.3901 0.3901 0.3901 0.4567 0.524 0.524 0.524 0.524 0.524
Girder Gbottom Mpa -1.907 -1.907 -1.907 -1.724 -1.538 -1.538 -1.538 -1.538 -1.538
Total Stresses (A+B +C+D+E+F+G+H) (Without SV)
Dtop Mpa -1.872 -1.755 -1.676 -0.913 -0.198 -0.114 0.4979 1.0579 1.1512
Deck Dbottom Mpa 0.1774 0.2694 0.3325 0.9434 1.4887 1.5516 2.0082 2.4261 2.4957
Gtop Mpa 1.259 1.3769 1.4656 3.2441 6.2766 6.3362 7.4721 8.5442 9.0178
Girder Gbottom Mpa 5.7604 5.5741 5.4389 6.0548 7.9709 7.8286 6.2337 4.7649 4.3323
Total Stresses (A+B +C+D+E+F+G+H) (With SV Loading)
Dtop Mpa -0.173 -0.116 -0.058 0.4926 1.0996 1.1795 2.1622 2.8354 2.9519
Deck Dbottom Mpa -0.213 -0.167 -0.122 0.3032 0.7485 0.8081 1.5414 2.0438 2.1307
Gtop Mpa 0.8689 0.9401 1.0113 2.604 5.5364 5.5927 7.0052 8.1619 8.6528
Girder Gbottom Mpa 7.6677 7.5645 7.4602 8.1666 10.062 9.9277 7.626 5.9412 5.4644

Max Compressive stress = 10.062 Mpa < 24 Mpa OK


Max Tensile Stress = 0.8689 Mpa >= -3.516 Mpa OK

EPC Contractor-M/s Krishna Constructions 212


Design ch-109+720
Design of PSC Girder

7.3) Rare Combination LC-SR7.3 : At day 92 Structure open to LL + temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.6164 0.4478 0.3 -0.434 -0.394 -0.633 -3.558 -5.114 -5.369
Girder Gbottom Mpa 7.7954 7.9731 8.1287 11.655 17.224 17.478 20.67 22.488 22.895

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder Gbottom Mpa 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0107 0.0201 0.1063 0.1964 0.2083 0.3559 0.4423 0.4729
Deck Dbottom Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Gtop Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Girder Gbottom Mpa 0 -0.015 -0.028 -0.173 -0.375 -0.397 -0.679 -0.843 -0.902
F) Stresses due to Live load (Without SV) Load factor = 0.75
Dtop Mpa 0 0.0794 0.1321 0.584 0.9815 1.0358 1.3841 1.7393 1.7863
Deck Dbottom Mpa 0 0.0627 0.1044 0.4499 0.7324 0.773 1.0329 1.2979 1.333
Gtop Mpa 0 0.0627 0.1044 0.4499 0.7324 0.773 1.0329 1.2979 1.333
Girder Gbottom Mpa 0 -0.111 -0.185 -0.952 -1.871 -1.975 -2.639 -3.316 -3.406
F.1) Stresses due to Live load (With SV) Load factor = 0.75
Dtop Mpa 0 0.035 0.0712 0.4054 0.7642 0.8152 1.4416 1.8817 1.9461
Deck Dbottom Mpa 0 0.0276 0.0563 0.3123 0.5703 0.6083 1.0757 1.4042 1.4522
Gtop Mpa 0 0.0276 0.0563 0.3123 0.5703 0.6083 1.0757 1.4042 1.4522
Girder Gbottom Mpa 0 -0.049 -0.1 -0.661 -1.457 -1.554 -2.749 -3.588 -3.711

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.173 -0.173 -0.173 -0.154 -0.116 -0.116 -0.116 -0.116 -0.116
Deck Dbottom Mpa -0.213 -0.213 -0.213 -0.195 -0.158 -0.158 -0.158 -0.158 -0.158
Gtop Mpa 0.2681 0.2681 0.2681 0.2857 0.3223 0.3223 0.3223 0.3223 0.3223
Girder Gbottom Mpa -0.144 -0.144 -0.144 -0.141 -0.124 -0.124 -0.124 -0.124 -0.124
H) +ve temperature stresses Load factor = 1
Dtop Mpa 4.52 4.52 4.52 4.6996 4.8808 4.8808 4.8808 4.8808 4.8808
Deck Dbottom Mpa -1.32 -1.32 -1.32 -1.196 -1.071 -1.071 -1.071 -1.071 -1.071
Gtop Mpa -1.32 -1.32 -1.32 -1.196 -1.071 -1.071 -1.071 -1.071 -1.071
Girder Gbottom Mpa 2.8058 2.8058 2.8058 2.3486 1.8872 1.8872 1.8872 1.8872 1.8872
Total Stresses (A+B +C+D+E+F+G+H) (Without SV)
Dtop Mpa 4.3466 4.4367 4.4989 5.2356 5.943 6.0092 6.505 6.9466 7.0242
Deck Dbottom Mpa -1.533 -1.461 -1.412 -0.859 -0.351 -0.301 0.0687 0.3983 0.4562
Gtop Mpa -0.451 -0.354 -0.279 1.4414 4.4372 4.4833 5.5326 6.5164 6.9783
Girder Gbottom Mpa 10.474 10.324 10.214 10.444 12.02 11.912 10.539 9.2958 8.8931
Total Stresses (A+B +C+D+E+F+G+H) (With SV Loading)
Dtop Mpa -0.173 -0.128 -0.082 0.3574 0.8449 0.9078 1.6816 2.2082 2.3032
Deck Dbottom Mpa -0.213 -0.177 -0.141 0.1991 0.5584 0.6053 1.1828 1.5758 1.6466
Gtop Mpa 0.8689 0.9308 0.9925 2.4999 5.3463 5.3899 6.6466 7.6938 8.1687
Girder Gbottom Mpa 7.6677 7.5808 7.4935 8.3869 10.547 10.446 8.5422 7.1371 6.7013

EPC Contractor-M/s Krishna Constructions 213


Design ch-109+720
Design of PSC Girder

Max Compressive stress = 12.02 Mpa < 24 Mpa OK


Max Tensile Stress = -0.451 Mpa >= -3.516 Mpa OK

7.4) Rare Combination LC-SR7.4 : At day 92 Structure open to LL - temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.6164 0.4478 0.3 -0.434 -0.394 -0.633 -3.558 -5.114 -5.369
Girder Gbottom Mpa 7.7954 7.9731 8.1287 11.655 17.224 17.478 20.67 22.488 22.895

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder Gbottom Mpa 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0107 0.0201 0.1063 0.1964 0.2083 0.3559 0.4423 0.4729
Deck Dbottom Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Gtop Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Girder Gbottom Mpa 0 -0.015 -0.028 -0.173 -0.375 -0.397 -0.679 -0.843 -0.902
F) Stresses due to Live load (Without SV) Load factor = 0.75
Dtop Mpa 0 0.0794 0.1321 0.584 0.9815 1.0358 1.3841 1.7393 1.7863
Deck Dbottom Mpa 0 0.0627 0.1044 0.4499 0.7324 0.773 1.0329 1.2979 1.333
Gtop Mpa 0 0.0627 0.1044 0.4499 0.7324 0.773 1.0329 1.2979 1.333
Girder Gbottom Mpa 0 -0.111 -0.185 -0.952 -1.871 -1.975 -2.639 -3.316 -3.406
F.1) Stresses due to Live load (With SV) Load factor = 0.75
Dtop Mpa 0 0.035 0.0712 0.4054 0.7642 0.8152 1.4416 1.8817 1.9461
Deck Dbottom Mpa 0 0.0276 0.0563 0.3123 0.5703 0.6083 1.0757 1.4042 1.4522
Gtop Mpa 0 0.0276 0.0563 0.3123 0.5703 0.6083 1.0757 1.4042 1.4522
Girder Gbottom Mpa 0 -0.049 -0.1 -0.661 -1.457 -1.554 -2.749 -3.588 -3.711

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.173 -0.173 -0.173 -0.154 -0.116 -0.116 -0.116 -0.116 -0.116
Deck Dbottom Mpa -0.213 -0.213 -0.213 -0.195 -0.158 -0.158 -0.158 -0.158 -0.158
Gtop Mpa 0.2681 0.2681 0.2681 0.2857 0.3223 0.3223 0.3223 0.3223 0.3223
Girder Gbottom Mpa -0.144 -0.144 -0.144 -0.141 -0.124 -0.124 -0.124 -0.124 -0.124
H) -ve temperature stresses Load factor = 1
Dtop Mpa -2.831 -2.831 -2.831 -2.739 -2.646 -2.646 -2.646 -2.646 -2.646
Deck Dbottom Mpa 0.6502 0.6502 0.6502 0.7612 0.8733 0.8733 0.8733 0.8733 0.8733
Gtop Mpa 0.6502 0.6502 0.6502 0.7612 0.8733 0.8733 0.8733 0.8733 0.8733
Girder Gbottom Mpa -3.179 -3.179 -3.179 -2.873 -2.564 -2.564 -2.564 -2.564 -2.564
Total Stresses (A+B +C+D+E+F+G+H) (Without SV)
Dtop Mpa -3.004 -2.914 -2.852 -2.203 -1.584 -1.518 -1.022 -0.58 -0.503
Deck Dbottom Mpa 0.4375 0.5086 0.5577 1.0979 1.5938 1.6432 2.0132 2.3428 2.4007
Gtop Mpa 1.519 1.6161 1.6908 3.3987 6.3817 6.4279 7.4771 8.4609 8.9228
Girder

EPC Contractor-M/s Krishna Constructions 214


Design ch-109+720
Design of PSC Girder

Girder Gbottom Mpa 4.4889 4.3397 4.2292 5.223 7.5692 7.4614 6.0879 4.8448 4.4421
Total Stresses (A+B +C+D+E+F+G+H) (With SV Loading)
Dtop Mpa -0.173 -0.128 -0.082 0.3574 0.8449 0.9078 1.6816 2.2082 2.3032
Deck Dbottom Mpa -0.213 -0.177 -0.141 0.1991 0.5584 0.6053 1.1828 1.5758 1.6466
Gtop Mpa 0.8689 0.9308 0.9925 2.4999 5.3463 5.3899 6.6466 7.6938 8.1687
Girder Gbottom Mpa 7.6677 7.5808 7.4935 8.3869 10.547 10.446 8.5422 7.1371 6.7013

Max Compressive stress = 10.547 Mpa < 24 Mpa OK


Max Tensile Stress = 0.8689 Mpa >= -3.516 Mpa OK

8) Rare Combination LC-SR8 : At day 36500


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.6515 0.5002 0.3677 -0.25 -0.148 -0.357 -2.927 -4.298 -4.517
Girder Gbottom Mpa 6.8121 6.9712 7.11 10.101 14.632 14.852 17.651 19.239 19.58

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder Gbottom Mpa 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.1) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.2) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0107 0.0201 0.1063 0.1964 0.2083 0.3559 0.4423 0.4729
Deck Dbottom Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Gtop Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Girder Gbottom Mpa 0 -0.015 -0.028 -0.173 -0.375 -0.397 -0.679 -0.843 -0.902
F) Stresses due to Live load (Without SV) Load factor = 1
Dtop Mpa 0 0.1058 0.1761 0.7787 1.3087 1.3811 1.8455 2.319 2.3818
Deck Dbottom Mpa 0 0.0836 0.1392 0.5999 0.9766 1.0306 1.3772 1.7306 1.7774
Gtop Mpa 0 0.0836 0.1392 0.5999 0.9766 1.0306 1.3772 1.7306 1.7774
Girder Gbottom Mpa 0 -0.149 -0.247 -1.269 -2.495 -2.633 -3.519 -4.422 -4.541
F.1) Stresses due to Live load (With SV) Load factor = 1
Dtop Mpa 0 0.0466 0.0949 0.5406 1.0189 1.0869 1.9221 2.5089 2.5948
Deck Dbottom Mpa 0 0.0368 0.075 0.4165 0.7604 0.8111 1.4343 1.8722 1.9363
Gtop Mpa 0 0.0368 0.075 0.4165 0.7604 0.8111 1.4343 1.8722 1.9363
Girder Gbottom Mpa 0 -0.065 -0.133 -0.881 -1.943 -2.073 -3.665 -4.784 -4.948

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.713 -0.713 -0.713 -0.635 -0.477 -0.477 -0.477 -0.477 -0.477
Deck Dbottom Mpa -0.875 -0.875 -0.875 -0.803 -0.652 -0.652 -0.652 -0.652 -0.652
Gtop Mpa 1.1035 1.1035 1.1035 1.1759 1.3266 1.3266 1.3266 1.3266 1.3266
Girder Gbottom Mpa -0.592 -0.592 -0.592 -0.58 -0.511 -0.511 -0.511 -0.511 -0.511
Total Stresses (A+B +C+D+E+F+G+H) (Without SV)
Dtop Mpa -0.713 -0.597 -0.517 0.25 1.0286 1.1129 1.7248 2.2848 2.3781
Deck Dbottom Mpa -0.875 -0.783 -0.72 -0.121 0.4709 0.5338 0.9904 1.4083 1.478

EPC Contractor-M/s Krishna Constructions 215


Design ch-109+720
Design of PSC Girder

Gtop Mpa 1.7394 1.8745 1.9785 3.8616 7.0034 7.0927 8.5837 9.841 10.35
Girder Gbottom Mpa 6.2363 6.0314 5.8794 5.7851 6.5304 6.354 4.3663 2.6671 2.169
Total Stresses (A+B +C+D+E+F+G+H) (With SV Loading)
Dtop Mpa 0 0.0573 0.1151 0.6469 1.2154 1.2953 2.2779 2.9512 3.0677
Deck Dbottom Mpa 0 0.0453 0.0909 0.4983 0.907 0.9666 1.6999 2.2023 2.2892
Gtop Mpa 0.6359 0.7243 0.8109 2.5022 5.4605 5.5466 7.3142 8.656 9.1821
Girder Gbottom Mpa 6.8282 6.7064 6.5852 6.7536 7.5939 7.4259 4.7313 2.8161 2.2739

Max Compressive stress = 10.35 Mpa < 24 Mpa OK


Max Tensile Stress = 0.6359 Mpa >= -3.516 Mpa OK

8.1) Rare Combination LC-SR8.1 : At day 36500 + temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.6515 0.5002 0.3677 -0.25 -0.148 -0.357 -2.927 -4.298 -4.517
Girder Gbottom Mpa 6.8121 6.9712 7.11 10.101 14.632 14.852 17.651 19.239 19.58

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder Gbottom Mpa 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.1) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.2) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0107 0.0201 0.1063 0.1964 0.2083 0.3559 0.4423 0.4729
Deck Dbottom Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Gtop Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Girder Gbottom Mpa 0 -0.015 -0.028 -0.173 -0.375 -0.397 -0.679 -0.843 -0.902
F) Stresses due to Live load (Without SV) Load factor = 1
Dtop Mpa 0 0.1058 0.1761 0.7787 1.3087 1.3811 1.8455 2.319 2.3818
Deck Dbottom Mpa 0 0.0836 0.1392 0.5999 0.9766 1.0306 1.3772 1.7306 1.7774
Gtop Mpa 0 0.0836 0.1392 0.5999 0.9766 1.0306 1.3772 1.7306 1.7774
Girder Gbottom Mpa 0 -0.149 -0.247 -1.269 -2.495 -2.633 -3.519 -4.422 -4.541
F.1) Stresses due to Live load (With SV) Load factor = 1
Dtop Mpa 0 0.0466 0.0949 0.5406 1.0189 1.0869 1.9221 2.5089 2.5948
Deck Dbottom Mpa 0 0.0368 0.075 0.4165 0.7604 0.8111 1.4343 1.8722 1.9363
Gtop Mpa 0 0.0368 0.075 0.4165 0.7604 0.8111 1.4343 1.8722 1.9363
Girder Gbottom Mpa 0 -0.065 -0.133 -0.881 -1.943 -2.073 -3.665 -4.784 -4.948

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.713 -0.713 -0.713 -0.635 -0.477 -0.477 -0.477 -0.477 -0.477
Deck Dbottom Mpa -0.875 -0.875 -0.875 -0.803 -0.652 -0.652 -0.652 -0.652 -0.652
Gtop Mpa 1.1035 1.1035 1.1035 1.1759 1.3266 1.3266 1.3266 1.3266 1.3266
Girder Gbottom Mpa -0.592 -0.592 -0.592 -0.58 -0.511 -0.511 -0.511 -0.511 -0.511

H) +ve temperature stresses Load factor = 0.6

EPC Contractor-M/s Krishna Constructions 216


Design ch-109+720
Design of PSC Girder

Dtop Mpa 2.712 2.712 2.712 2.8197 2.9285 2.9285 2.9285 2.9285 2.9285
Deck Dbottom Mpa -0.792 -0.792 -0.792 -0.718 -0.643 -0.643 -0.643 -0.643 -0.643
Gtop Mpa -0.792 -0.792 -0.792 -0.718 -0.643 -0.643 -0.643 -0.643 -0.643
Girder Gbottom Mpa 1.6835 1.6835 1.6835 1.4091 1.1323 1.1323 1.1323 1.1323 1.1323
Total Stresses (A+B +C+D+E+F+G+H) (Without SV)
Dtop Mpa 1.9987 2.1152 2.1949 3.0697 3.9571 4.0414 4.6533 5.2133 5.3066
Deck Dbottom Mpa -1.667 -1.575 -1.512 -0.839 -0.172 -0.109 0.3477 0.7656 0.8352
Gtop Mpa 0.9475 1.0826 1.1867 3.1439 6.3606 6.45 7.9409 9.1982 9.707
Girder Gbottom Mpa 7.9198 7.7149 7.5628 7.1943 7.6627 7.4863 5.4986 3.7994 3.3013
Total Stresses (A+B +C+D+E+F+G+H) (With SV Loading)
Dtop Mpa -0.713 -0.656 -0.598 0.0119 0.7389 0.8188 1.8014 2.4747 2.5911
Deck Dbottom Mpa -0.875 -0.83 -0.785 -0.305 0.2547 0.3143 1.0476 1.55 1.6369
Gtop Mpa 1.7394 1.8277 1.9144 3.6781 6.7871 6.8732 8.6408 9.9827 10.509
Girder Gbottom Mpa 6.2363 6.1145 5.9933 6.1733 7.0829 6.9149 4.2203 2.3051 1.7629

Max Compressive stress = 10.509 Mpa < 24 Mpa OK


Max Tensile Stress = 0.9475 Mpa >= -3.516 Mpa OK

8.2) Rare Combination LC-SR8.2 : At day 36500 - temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.6515 0.5002 0.3677 -0.25 -0.148 -0.357 -2.927 -4.298 -4.517
Girder Gbottom Mpa 6.8121 6.9712 7.11 10.101 14.632 14.852 17.651 19.239 19.58

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder Gbottom Mpa 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.1) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.2) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0107 0.0201 0.1063 0.1964 0.2083 0.3559 0.4423 0.4729
Deck Dbottom Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Gtop Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Girder Gbottom Mpa 0 -0.015 -0.028 -0.173 -0.375 -0.397 -0.679 -0.843 -0.902
F) Stresses due to Live load (Without SV) Load factor = 1
Dtop Mpa 0 0.1058 0.1761 0.7787 1.3087 1.3811 1.8455 2.319 2.3818
Deck Dbottom Mpa 0 0.0836 0.1392 0.5999 0.9766 1.0306 1.3772 1.7306 1.7774
Gtop Mpa 0 0.0836 0.1392 0.5999 0.9766 1.0306 1.3772 1.7306 1.7774
Girder Gbottom Mpa 0 -0.149 -0.247 -1.269 -2.495 -2.633 -3.519 -4.422 -4.541
F.1) Stresses due to Live load (With SV) Load factor = 1
Dtop Mpa 0 0.0466 0.0949 0.5406 1.0189 1.0869 1.9221 2.5089 2.5948
Deck Dbottom Mpa 0 0.0368 0.075 0.4165 0.7604 0.8111 1.4343 1.8722 1.9363
Gtop Mpa 0 0.0368 0.075 0.4165 0.7604 0.8111 1.4343 1.8722 1.9363
Girder Gbottom Mpa 0 -0.065 -0.133 -0.881 -1.943 -2.073 -3.665 -4.784 -4.948

EPC Contractor-M/s Krishna Constructions 217


Design ch-109+720
Design of PSC Girder

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.713 -0.713 -0.713 -0.635 -0.477 -0.477 -0.477 -0.477 -0.477
Deck Dbottom Mpa -0.875 -0.875 -0.875 -0.803 -0.652 -0.652 -0.652 -0.652 -0.652
Gtop Mpa 1.1035 1.1035 1.1035 1.1759 1.3266 1.3266 1.3266 1.3266 1.3266
Girder Gbottom Mpa -0.592 -0.592 -0.592 -0.58 -0.511 -0.511 -0.511 -0.511 -0.511

H) -ve temperature stresses Load factor = 0.6


Dtop Mpa -1.699 -1.699 -1.699 -1.643 -1.588 -1.588 -1.588 -1.588 -1.588
Deck Dbottom Mpa 0.3901 0.3901 0.3901 0.4567 0.524 0.524 0.524 0.524 0.524
Gtop Mpa 0.3901 0.3901 0.3901 0.4567 0.524 0.524 0.524 0.524 0.524
Girder Gbottom Mpa -1.907 -1.907 -1.907 -1.724 -1.538 -1.538 -1.538 -1.538 -1.538
Total Stresses (A+B +C+D+E+F+G+H) (Without SV)
Dtop Mpa -2.412 -2.295 -2.216 -1.393 -0.559 -0.475 0.1371 0.6971 0.7904
Deck Dbottom Mpa -0.485 -0.393 -0.33 0.3355 0.9949 1.0577 1.5144 1.9323 2.0019
Gtop Mpa 2.1295 2.2646 2.3686 4.3183 7.5273 7.6167 9.1076 10.365 10.874
Girder Gbottom Mpa 4.329 4.1241 3.9721 4.0615 4.9921 4.8158 2.8281 1.1289 0.6308
Total Stresses (A+B +C+D+E+F+G+H) (With SV Loading)
Dtop Mpa -0.713 -0.656 -0.598 0.0119 0.7389 0.8188 1.8014 2.4747 2.5911
Deck Dbottom Mpa -0.875 -0.83 -0.785 -0.305 0.2547 0.3143 1.0476 1.55 1.6369
Gtop Mpa 1.7394 1.8277 1.9144 3.6781 6.7871 6.8732 8.6408 9.9827 10.509
Girder Gbottom Mpa 6.2363 6.1145 5.9933 6.1733 7.0829 6.9149 4.2203 2.3051 1.7629

Max Compressive stress = 10.874 Mpa < 24 Mpa OK


Max Tensile Stress = 0.6308 Mpa >= -3.516 Mpa OK

8.3) Rare Combination LC-SR8.3 : At day 36500 + temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.6515 0.5002 0.3677 -0.25 -0.148 -0.357 -2.927 -4.298 -4.517
Girder Gbottom Mpa 6.8121 6.9712 7.11 10.101 14.632 14.852 17.651 19.239 19.58

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder Gbottom Mpa 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.1) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.2) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0107 0.0201 0.1063 0.1964 0.2083 0.3559 0.4423 0.4729
Deck Dbottom Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Gtop Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Girder Gbottom Mpa 0 -0.015 -0.028 -0.173 -0.375 -0.397 -0.679 -0.843 -0.902
F) Stresses due to Live load (Without SV) Load factor = 0.75
Dtop Mpa 0 0.0794 0.1321 0.584 0.9815 1.0358 1.3841 1.7393 1.7863
Deck Dbottom Mpa 0 0.0627 0.1044 0.4499 0.7324 0.773 1.0329 1.2979 1.333
Gtop Mpa 0 0.0627 0.1044 0.4499 0.7324 0.773 1.0329 1.2979 1.333
Girder

EPC Contractor-M/s Krishna Constructions 218


Design ch-109+720
Design of PSC Girder

Girder Gbottom Mpa 0 -0.111 -0.185 -0.952 -1.871 -1.975 -2.639 -3.316 -3.406
F.1) Stresses due to Live load (With SV) Load factor = 0.75
Dtop Mpa 0 0.035 0.0712 0.4054 0.7642 0.8152 1.4416 1.8817 1.9461
Deck Dbottom Mpa 0 0.0276 0.0563 0.3123 0.5703 0.6083 1.0757 1.4042 1.4522
Gtop Mpa 0 0.0276 0.0563 0.3123 0.5703 0.6083 1.0757 1.4042 1.4522
Girder Gbottom Mpa 0 -0.049 -0.1 -0.661 -1.457 -1.554 -2.749 -3.588 -3.711

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.713 -0.713 -0.713 -0.635 -0.477 -0.477 -0.477 -0.477 -0.477
Deck Dbottom Mpa -0.875 -0.875 -0.875 -0.803 -0.652 -0.652 -0.652 -0.652 -0.652
Gtop Mpa 1.1035 1.1035 1.1035 1.1759 1.3266 1.3266 1.3266 1.3266 1.3266
Girder Gbottom Mpa -0.592 -0.592 -0.592 -0.58 -0.511 -0.511 -0.511 -0.511 -0.511

H) +ve temperature stresses Load factor = 1


Dtop Mpa 4.52 4.52 4.52 4.6996 4.8808 4.8808 4.8808 4.8808 4.8808
Deck Dbottom Mpa -1.32 -1.32 -1.32 -1.196 -1.071 -1.071 -1.071 -1.071 -1.071
Gtop Mpa -1.32 -1.32 -1.32 -1.196 -1.071 -1.071 -1.071 -1.071 -1.071
Girder Gbottom Mpa 2.8058 2.8058 2.8058 2.3486 1.8872 1.8872 1.8872 1.8872 1.8872
Total Stresses (A+B +C+D+E+F+G+H) (Without SV)
Dtop Mpa 3.8067 3.8967 3.9589 4.7549 5.5822 5.6484 6.1443 6.5859 6.6635
Deck Dbottom Mpa -2.195 -2.124 -2.075 -1.467 -0.844 -0.795 -0.425 -0.096 -0.038
Gtop Mpa 0.4196 0.5338 0.624 2.5155 5.688 5.7638 7.1682 8.3371 8.8342
Girder Gbottom Mpa 9.0421 8.8743 8.7469 8.4511 9.0414 8.8995 7.1332 5.6597 5.1915
Total Stresses (A+B +C+D+E+F+G+H) (With SV Loading)
Dtop Mpa -0.713 -0.668 -0.622 -0.123 0.4841 0.547 1.3209 1.8474 1.9424
Deck Dbottom Mpa -0.875 -0.839 -0.803 -0.409 0.0646 0.1115 0.689 1.0819 1.1528
Gtop Mpa 1.7394 1.8185 1.8956 3.574 6.597 6.6704 8.2822 9.5146 10.025
Girder Gbottom Mpa 6.2363 6.1309 6.0266 6.3936 7.5686 7.433 5.1365 3.5011 2.9998

Max Compressive stress = 10.025 Mpa < 24 Mpa OK


Max Tensile Stress = 0.4196 Mpa >= -3.516 Mpa OK

8.4) Rare Combination LC-SR8.4 : At day 36500 - temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.6515 0.5002 0.3677 -0.25 -0.148 -0.357 -2.927 -4.298 -4.517
Girder Gbottom Mpa 6.8121 6.9712 7.11 10.101 14.632 14.852 17.651 19.239 19.58

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder Gbottom Mpa 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.1) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.2) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0107 0.0201 0.1063 0.1964 0.2083 0.3559 0.4423 0.4729
Deck

EPC Contractor-M/s Krishna Constructions 219


Design ch-109+720
Design of PSC Girder

Deck Dbottom Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Gtop Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Girder Gbottom Mpa 0 -0.015 -0.028 -0.173 -0.375 -0.397 -0.679 -0.843 -0.902
F) Stresses due to Live load (Without SV) Load factor = 0.75
Dtop Mpa 0 0.0794 0.1321 0.584 0.9815 1.0358 1.3841 1.7393 1.7863
Deck Dbottom Mpa 0 0.0627 0.1044 0.4499 0.7324 0.773 1.0329 1.2979 1.333
Gtop Mpa 0 0.0627 0.1044 0.4499 0.7324 0.773 1.0329 1.2979 1.333
Girder Gbottom Mpa 0 -0.111 -0.185 -0.952 -1.871 -1.975 -2.639 -3.316 -3.406
F.1) Stresses due to Live load (With SV) Load factor = 0.75
Dtop Mpa 0 0.035 0.0712 0.4054 0.7642 0.8152 1.4416 1.8817 1.9461
Deck Dbottom Mpa 0 0.0276 0.0563 0.3123 0.5703 0.6083 1.0757 1.4042 1.4522
Gtop Mpa 0 0.0276 0.0563 0.3123 0.5703 0.6083 1.0757 1.4042 1.4522
Girder Gbottom Mpa 0 -0.049 -0.1 -0.661 -1.457 -1.554 -2.749 -3.588 -3.711

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.713 -0.713 -0.713 -0.635 -0.477 -0.477 -0.477 -0.477 -0.477
Deck Dbottom Mpa -0.875 -0.875 -0.875 -0.803 -0.652 -0.652 -0.652 -0.652 -0.652
Gtop Mpa 1.1035 1.1035 1.1035 1.1759 1.3266 1.3266 1.3266 1.3266 1.3266
Girder Gbottom Mpa -0.592 -0.592 -0.592 -0.58 -0.511 -0.511 -0.511 -0.511 -0.511

H) -ve temperature stresses Load factor = 1


Dtop Mpa -2.831 -2.831 -2.831 -2.739 -2.646 -2.646 -2.646 -2.646 -2.646
Deck Dbottom Mpa 0.6502 0.6502 0.6502 0.7612 0.8733 0.8733 0.8733 0.8733 0.8733
Gtop Mpa 0.6502 0.6502 0.6502 0.7612 0.8733 0.8733 0.8733 0.8733 0.8733
Girder Gbottom Mpa -3.179 -3.179 -3.179 -2.873 -2.564 -2.564 -2.564 -2.564 -2.564
Total Stresses (A+B +C+D+E+F+G+H)
Dtop Mpa -3.544 -3.454 -3.392 -2.684 -1.945 -1.879 -1.383 -0.941 -0.863
Deck Dbottom Mpa -0.225 -0.154 -0.105 0.49 1.1 1.1494 1.5194 1.849 1.9069
Gtop Mpa 2.3895 2.5038 2.5939 4.4728 7.6325 7.7083 9.1127 10.282 10.779
Girder Gbottom Mpa 3.0575 2.8897 2.7623 3.2298 4.5904 4.4486 2.6823 1.2088 0.7406
Total Stresses (A+B +C+D+E+F+G+H)
Dtop Mpa -0.713 -0.668 -0.622 -0.123 0.4841 0.547 1.3209 1.8474 1.9424
Deck Dbottom Mpa -0.875 -0.839 -0.803 -0.409 0.0646 0.1115 0.689 1.0819 1.1528
Gtop Mpa 1.7394 1.8185 1.8956 3.574 6.597 6.6704 8.2822 9.5146 10.025
Girder Gbottom Mpa 6.2363 6.1309 6.0266 6.3936 7.5686 7.433 5.1365 3.5011 2.9998

Max Compressive stress = 10.779 Mpa < 24 Mpa OK


Max Tensile Stress = 0.7406 Mpa >= -3.516 Mpa OK

SUMMARY FOR SLS RARE COMBINATION


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
1) Rare Combination LC-SR1 : At the time of 1st stage prestress, just after ES loss of Stage -I cables
Total Stresses (A+B)
Gtop Mpa -2.663 -2.593 -2.535 -1.956 -0.653 -0.574 0.4343 1.0932 1.3729
Girder Gbottom Mpa 8.4143 8.3453 8.2871 9.5813 12.2 12.129 11.247 10.717 10.552
2) Rare Combination LC-SR2 At day 28 Just before II Stage prestressing
Total Stresses (A+B)
Gtop Mpa -2.549 -2.477 -2.416 -1.8 -0.464 -0.38 0.6822 1.3707 1.6595
Girder Gbottom Mpa 8.0535 7.9819 7.9214 9.0586 11.354 11.278 10.333 9.764 9.5766
3) Rare Combination LC-SR3 : At day 28 Just after II Stage prestressing after ES
Total Stresses (A+B)
Gtop Mpa 0.6544 0.601 0.5517 0.8605 2.2543 2.1579 1.0205 0.555 0.6815
Girder Gbottom Mpa 8.073 8.1323 8.1868 10.817 15.444 15.558 16.965 17.697 17.715
4) Rare Combination LC-SR4 : At day 35 At the time of casting of deck slab
Total Stresses (A+B)
Gtop Mpa 0.5969 0.6196 0.6421 1.7848 4.2552 4.2453 4.8587 5.4924 5.8974
Girder Gbottom Mpa 8.0129 7.9929 7.9727 9.6841 13.059 13.081 12.668 12.247 11.975
5) Rare Combination LC-SR5 : At day 63 At the time of transfer over permanent bearings

EPC Contractor-M/s Krishna Constructions 220


Design ch-109+720
Design of PSC Girder

Total Stresses (A+B)


Gtop Mpa 0.8796 0.9043 0.9288 2.1054 4.6242 4.6186 5.2741 5.92 6.3241
Girder Gbottom Mpa 7.7343 7.7126 7.6904 9.3321 12.577 12.597 12.179 11.776 11.516
6) Rare Combination LC-SR6 : At day 64 At the time of placing of SIDL
Total Stresses (A+B)
Gtop Mpa 0.8794 0.9126 0.9447 2.1877 4.7714 4.7749 5.5417 6.2527 6.6798
Girder Gbottom Mpa 7.7314 7.6946 7.6591 9.1537 12.193 12.19 11.49 10.921 10.603
7) Rare Combination LC-SR7 : At day 92 Structure open to LL
Total Stresses (A+B)
Gtop Mpa 0.8689 0.9868 1.0755 2.7874 5.7526 5.8122 6.9481 8.0202 8.4939
Girder Gbottom Mpa 7.6677 7.4814 7.3462 7.7784 9.5092 9.3668 7.772 6.3032 5.8706
7.1) Rare Combination LC-SR7.1 : At day 92 Structure open to LL + temperature stresses
Total Stresses (A+B)
Gtop Mpa 0.077 0.1949 0.2836 2.0698 5.1099 5.1695 6.3054 7.3775 7.8511
Girder Gbottom Mpa 9.3512 9.1648 9.0297 9.1875 10.641 10.499 8.9043 7.4355 7.0029
7.2) Rare Combination LC-SR7.2: At day 92 Structure open to LL - temperature stresses
Total Stresses (A+B)
Gtop Mpa 1.259 1.3769 1.4656 3.2441 6.2766 6.3362 7.4721 8.5442 9.0178
Girder Gbottom Mpa 5.7604 5.5741 5.4389 6.0548 7.9709 7.8286 6.2337 4.7649 4.3323
7.3) Rare Combination LC-SR7.3 : At day 92 Structure open to LL + temperature stresses
Total Stresses (A+B)
Gtop Mpa -0.451 -0.354 -0.279 1.4414 4.4372 4.4833 5.5326 6.5164 6.9783
Girder Gbottom Mpa 10.474 10.324 10.214 10.444 12.02 11.912 10.539 9.2958 8.8931
7.4) Rare Combination LC-SR7.4 : At day 92 Structure open to LL - temperature stresses
Total Stresses (A+B)
Gtop Mpa 1.519 1.6161 1.6908 3.3987 6.3817 6.4279 7.4771 8.4609 8.9228
Girder Gbottom Mpa 4.4889 4.3397 4.2292 5.223 7.5692 7.4614 6.0879 4.8448 4.4421

Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
8) Rare Combination LC-SR8 : At day 36500
Total Stresses (A+B)
Gtop Mpa 1.7394 1.8745 1.9785 3.8616 7.0034 7.0927 8.5837 9.841 10.35
Girder Gbottom Mpa 6.2363 6.0314 5.8794 5.7851 6.5304 6.354 4.3663 2.6671 2.169
8.1) Rare Combination LC-SR8.1 : At day 36500 + temperature stresses
Total Stresses (A+B)
Gtop Mpa 0.9475 1.0826 1.1867 3.1439 6.3606 6.45 7.9409 9.1982 9.707
Girder Gbottom Mpa 7.9198 7.7149 7.5628 7.1943 7.6627 7.4863 5.4986 3.7994 3.3013
8.2) Rare Combination LC-SR8.2 : At day 36500 - temperature stresses
Total Stresses (A+B)
Gtop Mpa 2.1295 2.2646 2.3686 4.3183 7.5273 7.6167 9.1076 10.365 10.874
Girder Gbottom Mpa 4.329 4.1241 3.9721 4.0615 4.9921 4.8158 2.8281 1.1289 0.6308
8.3) Rare Combination LC-SR8.3 : At day 36500 + temperature stresses
Total Stresses (A+B)
Gtop Mpa 0.4196 0.5338 0.624 2.5155 5.688 5.7638 7.1682 8.3371 8.8342
Girder Gbottom Mpa 9.0421 8.8743 8.7469 8.4511 9.0414 8.8995 7.1332 5.6597 5.1915
8.4) Rare Combination LC-SR8.4 : At day 36500 - temperature stresses
Total Stresses (A+B)
Gtop Mpa 2.3895 2.5038 2.5939 4.4728 7.6325 7.7083 9.1127 10.282 10.779
Girder Gbottom Mpa 3.0575 2.8897 2.7623 3.2298 4.5904 4.4486 2.6823 1.2088 0.7406

FREQUENT LOAD COMBINATIONS :


1) Frequent Combination LC-SF1 : At day 92 Structure open to LL
Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.6164 0.4478 0.3 -0.434 -0.394 -0.633 -3.558 -5.114 -5.369
Girder Gbottom Mpa 7.7954 7.9731 8.1287 11.655 17.224 17.478 20.67 22.488 22.895

B) Stresses due to Selfweight of girder Load factor = 1

EPC Contractor-M/s Krishna Constructions 221


Design ch-109+720
Design of PSC Girder

Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder Gbottom Mpa 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0107 0.0201 0.1063 0.1964 0.2083 0.3559 0.4423 0.4729
Deck Dbottom Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Gtop Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Girder Gbottom Mpa 0 -0.015 -0.028 -0.173 -0.375 -0.397 -0.679 -0.843 -0.902
F) Stresses due to Live load (Without SV) Load factor = 0.75
Dtop Mpa 0 0.0794 0.1321 0.584 0.9815 1.0358 1.3841 1.7393 1.7863
Deck Dbottom Mpa 0 0.0627 0.1044 0.4499 0.7324 0.773 1.0329 1.2979 1.333
Gtop Mpa 0 0.0627 0.1044 0.4499 0.7324 0.773 1.0329 1.2979 1.333
Girder Gbottom Mpa 0 -0.111 -0.185 -0.952 -1.871 -1.975 -2.639 -3.316 -3.406
F.1) Stresses due to Live load (With SV) Load factor = 0.75
Dtop Mpa 0 0.035 0.0712 0.4054 0.7642 0.8152 1.4416 1.8817 1.9461
Deck Dbottom Mpa 0 0.0276 0.0563 0.3123 0.5703 0.6083 1.0757 1.4042 1.4522
Gtop Mpa 0 0.0276 0.0563 0.3123 0.5703 0.6083 1.0757 1.4042 1.4522
Girder Gbottom Mpa 0 -0.049 -0.1 -0.661 -1.457 -1.554 -2.749 -3.588 -3.711

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.173 -0.173 -0.173 -0.154 -0.116 -0.116 -0.116 -0.116 -0.116
Deck Dbottom Mpa -0.213 -0.213 -0.213 -0.195 -0.158 -0.158 -0.158 -0.158 -0.158
Gtop Mpa 0.2681 0.2681 0.2681 0.2857 0.3223 0.3223 0.3223 0.3223 0.3223
Girder Gbottom Mpa -0.144 -0.144 -0.144 -0.141 -0.124 -0.124 -0.124 -0.124 -0.124
G) Stresses due to wind Load factor = 0.5
Dtop Mpa 0 0.0053 0.0099 0.0523 0.0967 0.1026 0.1752 0.2178 0.2328
Deck Dbottom Mpa 0 0.0042 0.0078 0.0403 0.0722 0.0765 0.1307 0.1625 0.1737
Gtop Mpa 0 0.0042 0.0078 0.0403 0.0722 0.0765 0.1307 0.1625 0.1737
Girder Gbottom Mpa 0 -0.007 -0.014 -0.085 -0.184 -0.196 -0.334 -0.415 -0.444
Total Stresses (A+B +C+D+E+F+G) (Without SV Loading)
Dtop Mpa -0.173 -0.083 -0.021 0.536 1.0622 1.1284 1.6242 2.0658 2.1434
Deck Dbottom Mpa -0.213 -0.142 -0.092 0.3367 0.7205 0.7699 1.14 1.4695 1.5274
Gtop Mpa 0.8689 0.9659 1.0407 2.6374 5.5085 5.5546 6.6038 7.5876 8.0495
Girder Gbottom Mpa 7.6677 7.5185 7.408 8.0957 10.133 10.025 8.6517 7.4086 7.0059
Total Stresses (A+B +C+D+E+F+G) (With SV Loading)
Dtop Mpa -0.173 -0.128 -0.082 0.3574 0.8449 0.9078 1.6816 2.2082 2.3032
Deck Dbottom Mpa -0.213 -0.177 -0.141 0.1991 0.5584 0.6053 1.1828 1.5758 1.6466
Gtop Mpa 0.8689 0.9308 0.9925 2.4999 5.3463 5.3899 6.6466 7.6938 8.1687
Girder Gbottom Mpa 7.6677 7.5808 7.4935 8.3869 10.547 10.446 8.5422 7.1371 6.7013
Total Stresses (A+B +C+D+E+F+G) wind downward
Dtop Mpa -0.173 -0.078 -0.011 0.5884 1.1589 1.2309 1.7994 2.2836 2.3763
Deck Dbottom Mpa -0.213 -0.137 -0.085 0.377 0.7927 0.8465 1.2707 1.632 1.7012
Gtop Mpa 0.8689 0.9701 1.0485 2.6778 5.5806 5.6311 6.7345 7.7501 8.2232
Girder Gbottom Mpa 7.6677 7.5111 7.3941 8.0104 9.9486 9.8296 8.3177 6.9934 6.562
Total Stresses (A+B +C+D+E+F+G) wind upward
Dtop Mpa -0.173 -0.089 -0.031 0.4837 0.9655 1.0258 1.449 1.8481 1.9106
Deck Dbottom Mpa -0.213 -0.146 -0.1 0.2964 0.6484 0.6934 1.0092 1.307 1.3537
Gtop Mpa 0.8689 0.9618 1.0328 2.5971 5.4363 5.478 6.473 7.4251 7.8758
Girder Gbottom Mpa 7.6677 7.5259 7.4219 8.1811 10.317 10.221 8.9858 7.8238 7.4498

EPC Contractor-M/s Krishna Constructions 222


Design ch-109+720
Design of PSC Girder

Max Compressive stress = 10.547 Mpa < 24 Mpa OK


Max Tensile Stress = 0.8689 Mpa >= -3.516 Mpa OK
Max Compressive stress (wind downward) = 9.9486 Mpa < 24 Mpa OK
Max Tensile Stress (wind downward) = 0.8689 Mpa >= -3.516 Mpa OK
Max Compressive stress (wind upward) = 10.317 Mpa < 24 Mpa OK
Max Tensile Stress (wind upward) = 0.8689 Mpa >= -3.516 Mpa OK

1.1) Frequent Combination LC-SF1.1 : At day 92 Structure open to LL + temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.6164 0.4478 0.3 -0.434 -0.394 -0.633 -3.558 -5.114 -5.369
Girder Gbottom Mpa 7.7954 7.9731 8.1287 11.655 17.224 17.478 20.67 22.488 22.895

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder Gbottom Mpa 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0107 0.0201 0.1063 0.1964 0.2083 0.3559 0.4423 0.4729
Deck Dbottom Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Gtop Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Girder Gbottom Mpa 0 -0.015 -0.028 -0.173 -0.375 -0.397 -0.679 -0.843 -0.902
F) Stresses due to Live load (Without SV) Load factor = 0.75
Dtop Mpa 0 0.0794 0.1321 0.584 0.9815 1.0358 1.3841 1.7393 1.7863
Deck Dbottom Mpa 0 0.0627 0.1044 0.4499 0.7324 0.773 1.0329 1.2979 1.333
Gtop Mpa 0 0.0627 0.1044 0.4499 0.7324 0.773 1.0329 1.2979 1.333
Girder Gbottom Mpa 0 -0.111 -0.185 -0.952 -1.871 -1.975 -2.639 -3.316 -3.406
F.1) Stresses due to Live load (With SV) Load factor = 0.75
Dtop Mpa 0 0.035 0.0712 0.4054 0.7642 0.8152 1.4416 1.8817 1.9461
Deck Dbottom Mpa 0 0.0276 0.0563 0.3123 0.5703 0.6083 1.0757 1.4042 1.4522
Gtop Mpa 0 0.0276 0.0563 0.3123 0.5703 0.6083 1.0757 1.4042 1.4522
Girder Gbottom Mpa 0 -0.049 -0.1 -0.661 -1.457 -1.554 -2.749 -3.588 -3.711

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.173 -0.173 -0.173 -0.154 -0.116 -0.116 -0.116 -0.116 -0.116
Deck Dbottom Mpa -0.213 -0.213 -0.213 -0.195 -0.158 -0.158 -0.158 -0.158 -0.158
Gtop Mpa 0.2681 0.2681 0.2681 0.2857 0.3223 0.3223 0.3223 0.3223 0.3223
Girder Gbottom Mpa -0.144 -0.144 -0.144 -0.141 -0.124 -0.124 -0.124 -0.124 -0.124
H) +ve temperature stresses Load factor = 0.5
Dtop Mpa 2.26 2.26 2.26 2.3498 2.4404 2.4404 2.4404 2.4404 2.4404
Deck Dbottom Mpa -0.66 -0.66 -0.66 -0.598 -0.536 -0.536 -0.536 -0.536 -0.536
Gtop Mpa -0.66 -0.66 -0.66 -0.598 -0.536 -0.536 -0.536 -0.536 -0.536
Girder Gbottom Mpa 1.4029 1.4029 1.4029 1.1743 0.9436 0.9436 0.9436 0.9436 0.9436
Total Stresses (A+B +C+D+E+F+G) (Without SV Loading)

EPC Contractor-M/s Krishna Constructions 223


Design ch-109+720
Design of PSC Girder

Dtop Mpa 2.0867 2.1767 2.2389 2.8858 3.5026 3.5688 4.0646 4.5062 4.5838
Deck Dbottom Mpa -0.873 -0.801 -0.752 -0.261 0.1849 0.2343 0.6044 0.9339 0.9918
Gtop Mpa 0.209 0.306 0.3808 2.0394 4.9728 5.019 6.0682 7.052 7.5139
Girder Gbottom Mpa 9.0706 8.9214 8.8109 9.27 11.077 10.969 9.5953 8.3522 7.9495
Total Stresses (A+B +C+D+E+F+G) (With SV Loading)
Dtop Mpa -0.173 -0.128 -0.082 0.3574 0.8449 0.9078 1.6816 2.2082 2.3032
Deck Dbottom Mpa -0.213 -0.177 -0.141 0.1991 0.5584 0.6053 1.1828 1.5758 1.6466
Gtop Mpa 0.8689 0.9308 0.9925 2.4999 5.3463 5.3899 6.6466 7.6938 8.1687
Girder Gbottom Mpa 7.6677 7.5808 7.4935 8.3869 10.547 10.446 8.5422 7.1371 6.7013

Max Compressive stress = 11.077 Mpa < 24 Mpa OK


Max Tensile Stress = 0.209 Mpa >= -3.516 Mpa OK

1.2) Frequent Combination LC-SF1.2 : At day 92 Structure open to LL - temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.6164 0.4478 0.3 -0.434 -0.394 -0.633 -3.558 -5.114 -5.369
Girder Gbottom Mpa 7.7954 7.9731 8.1287 11.655 17.224 17.478 20.67 22.488 22.895

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder Gbottom Mpa 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0107 0.0201 0.1063 0.1964 0.2083 0.3559 0.4423 0.4729
Deck Dbottom Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Gtop Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Girder Gbottom Mpa 0 -0.015 -0.028 -0.173 -0.375 -0.397 -0.679 -0.843 -0.902
F) Stresses due to Live load (Without SV) Load factor = 0.75
Dtop Mpa 0 0.0794 0.1321 0.584 0.9815 1.0358 1.3841 1.7393 1.7863
Deck Dbottom Mpa 0 0.0627 0.1044 0.4499 0.7324 0.773 1.0329 1.2979 1.333
Gtop Mpa 0 0.0627 0.1044 0.4499 0.7324 0.773 1.0329 1.2979 1.333
Girder Gbottom Mpa 0 -0.111 -0.185 -0.952 -1.871 -1.975 -2.639 -3.316 -3.406
F.1) Stresses due to Live load (With SV) Load factor = 0.75
Dtop Mpa 0 0.035 0.0712 0.4054 0.7642 0.8152 1.4416 1.8817 1.9461
Deck Dbottom Mpa 0 0.0276 0.0563 0.3123 0.5703 0.6083 1.0757 1.4042 1.4522
Gtop Mpa 0 0.0276 0.0563 0.3123 0.5703 0.6083 1.0757 1.4042 1.4522
Girder Gbottom Mpa 0 -0.049 -0.1 -0.661 -1.457 -1.554 -2.749 -3.588 -3.711

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.173 -0.173 -0.173 -0.154 -0.116 -0.116 -0.116 -0.116 -0.116
Deck Dbottom Mpa -0.213 -0.213 -0.213 -0.195 -0.158 -0.158 -0.158 -0.158 -0.158
Gtop Mpa 0.2681 0.2681 0.2681 0.2857 0.3223 0.3223 0.3223 0.3223 0.3223
Girder Gbottom Mpa -0.144 -0.144 -0.144 -0.141 -0.124 -0.124 -0.124 -0.124 -0.124

EPC Contractor-M/s Krishna Constructions 224


Design ch-109+720
Design of PSC Girder

H) -ve temperature stresses Load factor = 0.5


Dtop Mpa -1.416 -1.416 -1.416 -1.37 -1.323 -1.323 -1.323 -1.323 -1.323
Deck Dbottom Mpa 0.3251 0.3251 0.3251 0.3806 0.4366 0.4366 0.4366 0.4366 0.4366
Gtop Mpa 0.3251 0.3251 0.3251 0.3806 0.4366 0.4366 0.4366 0.4366 0.4366
Girder Gbottom Mpa -1.589 -1.589 -1.589 -1.436 -1.282 -1.282 -1.282 -1.282 -1.282
Total Stresses (A+B +C+D+E+F+G) (Without SV Loading)
Dtop Mpa -1.589 -1.499 -1.437 -0.833 -0.261 -0.195 0.3011 0.7427 0.8203
Deck Dbottom Mpa 0.1124 0.1835 0.2327 0.7173 1.1572 1.2066 1.5766 1.9061 1.9641
Gtop Mpa 1.1939 1.291 1.3657 3.018 5.9451 5.9912 7.0404 8.0242 8.4862
Girder Gbottom Mpa 6.0783 5.9291 5.8186 6.6594 8.8511 8.7433 7.3698 6.1267 5.724
Total Stresses (A+B +C+D+E+F+G) (With SV Loading)
Dtop Mpa -0.173 -0.128 -0.082 0.3574 0.8449 0.9078 1.6816 2.2082 2.3032
Deck Dbottom Mpa -0.213 -0.177 -0.141 0.1991 0.5584 0.6053 1.1828 1.5758 1.6466
Gtop Mpa 0.8689 0.9308 0.9925 2.4999 5.3463 5.3899 6.6466 7.6938 8.1687
Girder Gbottom Mpa 7.6677 7.5808 7.4935 8.3869 10.547 10.446 8.5422 7.1371 6.7013

Max Compressive stress = 10.547 Mpa < 24 Mpa OK


Max Tensile Stress = 0.8689 Mpa >= -3.516 Mpa OK

1.3) Frequent Combination LC-SF1.3 : At day 92 Structure open to LL + temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.6164 0.4478 0.3 -0.434 -0.394 -0.633 -3.558 -5.114 -5.369
Girder Gbottom Mpa 7.7954 7.9731 8.1287 11.655 17.224 17.478 20.67 22.488 22.895

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder Gbottom Mpa 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0107 0.0201 0.1063 0.1964 0.2083 0.3559 0.4423 0.4729
Deck Dbottom Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Gtop Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Girder Gbottom Mpa 0 -0.015 -0.028 -0.173 -0.375 -0.397 -0.679 -0.843 -0.902
F) Stresses due to Live load (Without SV) Load factor = 0.2
Dtop Mpa 0 0.0212 0.0352 0.1557 0.2617 0.2762 0.3691 0.4638 0.4764
Deck Dbottom Mpa 0 0.0167 0.0278 0.12 0.1953 0.2061 0.2754 0.3461 0.3555
Gtop Mpa 0 0.0167 0.0278 0.12 0.1953 0.2061 0.2754 0.3461 0.3555
Girder Gbottom Mpa 0 -0.03 -0.049 -0.254 -0.499 -0.527 -0.704 -0.884 -0.908
F.1) Stresses due to Live load (With SV) Load factor = 0.2
Dtop Mpa 0 0.0093 0.019 0.1081 0.2038 0.2174 0.3844 0.5018 0.519
Deck Dbottom Mpa 0 0.0074 0.015 0.0833 0.1521 0.1622 0.2869 0.3744 0.3873
Gtop Mpa 0 0.0074 0.015 0.0833 0.1521 0.1622 0.2869 0.3744 0.3873
Girder Gbottom Mpa 0 -0.013 -0.027 -0.176 -0.389 -0.415 -0.733 -0.957 -0.99

EPC Contractor-M/s Krishna Constructions 225


Design ch-109+720
Design of PSC Girder

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.173 -0.173 -0.173 -0.154 -0.116 -0.116 -0.116 -0.116 -0.116
Deck Dbottom Mpa -0.213 -0.213 -0.213 -0.195 -0.158 -0.158 -0.158 -0.158 -0.158
Gtop Mpa 0.2681 0.2681 0.2681 0.2857 0.3223 0.3223 0.3223 0.3223 0.3223
Girder Gbottom Mpa -0.144 -0.144 -0.144 -0.141 -0.124 -0.124 -0.124 -0.124 -0.124
H) +ve temperature stresses Load factor = 0.6
Dtop Mpa 2.712 2.712 2.712 2.8197 2.9285 2.9285 2.9285 2.9285 2.9285
Deck Dbottom Mpa -0.792 -0.792 -0.792 -0.718 -0.643 -0.643 -0.643 -0.643 -0.643
Gtop Mpa -0.792 -0.792 -0.792 -0.718 -0.643 -0.643 -0.643 -0.643 -0.643
Girder Gbottom Mpa 1.6835 1.6835 1.6835 1.4091 1.1323 1.1323 1.1323 1.1323 1.1323
Total Stresses (A+B +C+D+E+F+G) (Without SV Loading)
Dtop Mpa 2.5387 2.5705 2.594 2.9275 3.2709 3.2973 3.5377 3.7188 3.762
Deck Dbottom Mpa -1.005 -0.979 -0.961 -0.711 -0.459 -0.44 -0.26 -0.125 -0.093
Gtop Mpa 0.077 0.1281 0.1722 1.5898 4.3286 4.345 5.2036 5.993 6.4292
Girder Gbottom Mpa 9.3512 9.2836 9.2274 10.203 12.638 12.606 11.719 10.973 10.636
Total Stresses (A+B +C+D+E+F+G) (With SV Loading)
Dtop Mpa -0.173 -0.153 -0.134 0.0601 0.2844 0.3099 0.6245 0.8283 0.8761
Deck Dbottom Mpa -0.213 -0.197 -0.182 -0.03 0.1402 0.1592 0.3939 0.546 0.5817
Gtop Mpa 0.8689 0.9106 0.9513 2.2708 4.9281 4.9438 5.8578 6.6641 7.1038
Girder Gbottom Mpa 7.6677 7.6168 7.5668 8.8716 11.616 11.586 10.558 9.7682 9.4224

Max Compressive stress = 12.638 Mpa < 24 Mpa OK


Max Tensile Stress = 0.077 Mpa >= -3.516 Mpa OK

1.4) Frequent Combination LC-SF1.4 : At day 92 Structure open to LL - temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.6164 0.4478 0.3 -0.434 -0.394 -0.633 -3.558 -5.114 -5.369
Girder Gbottom Mpa 7.7954 7.9731 8.1287 11.655 17.224 17.478 20.67 22.488 22.895

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder Gbottom Mpa 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0107 0.0201 0.1063 0.1964 0.2083 0.3559 0.4423 0.4729
Deck Dbottom Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Gtop Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Girder Gbottom Mpa 0 -0.015 -0.028 -0.173 -0.375 -0.397 -0.679 -0.843 -0.902
F) Stresses due to Live load (Without SV) Load factor = 0.2
Dtop Mpa 0 0.0212 0.0352 0.1557 0.2617 0.2762 0.3691 0.4638 0.4764
Deck Dbottom Mpa 0 0.0167 0.0278 0.12 0.1953 0.2061 0.2754 0.3461 0.3555
Gtop Mpa 0 0.0167 0.0278 0.12 0.1953 0.2061 0.2754 0.3461 0.3555
Girder Gbottom Mpa 0 -0.03 -0.049 -0.254 -0.499 -0.527 -0.704 -0.884 -0.908

EPC Contractor-M/s Krishna Constructions 226


Design ch-109+720
Design of PSC Girder

F.1) Stresses due to Live load (With SV) Load factor = 0.2
Dtop Mpa 0 0.0093 0.019 0.1081 0.2038 0.2174 0.3844 0.5018 0.519
Deck Dbottom Mpa 0 0.0074 0.015 0.0833 0.1521 0.1622 0.2869 0.3744 0.3873
Gtop Mpa 0 0.0074 0.015 0.0833 0.1521 0.1622 0.2869 0.3744 0.3873
Girder Gbottom Mpa 0 -0.013 -0.027 -0.176 -0.389 -0.415 -0.733 -0.957 -0.99

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.173 -0.173 -0.173 -0.154 -0.116 -0.116 -0.116 -0.116 -0.116
Deck Dbottom Mpa -0.213 -0.213 -0.213 -0.195 -0.158 -0.158 -0.158 -0.158 -0.158
Gtop Mpa 0.2681 0.2681 0.2681 0.2857 0.3223 0.3223 0.3223 0.3223 0.3223
Girder Gbottom Mpa -0.144 -0.144 -0.144 -0.141 -0.124 -0.124 -0.124 -0.124 -0.124
H) -ve temperature stresses Load factor = 0.6
Dtop Mpa -1.699 -1.699 -1.699 -1.643 -1.588 -1.588 -1.588 -1.588 -1.588
Deck Dbottom Mpa 0.3901 0.3901 0.3901 0.4567 0.524 0.524 0.524 0.524 0.524
Gtop Mpa 0.3901 0.3901 0.3901 0.4567 0.524 0.524 0.524 0.524 0.524
Girder Gbottom Mpa -1.907 -1.907 -1.907 -1.724 -1.538 -1.538 -1.538 -1.538 -1.538
Total Stresses (A+B +C+D+E+F+G) (Without SV Loading)
Dtop Mpa -1.872 -1.84 -1.817 -1.536 -1.245 -1.219 -0.979 -0.797 -0.754
Deck Dbottom Mpa 0.1774 0.2026 0.2211 0.4635 0.7074 0.7271 0.9065 1.0417 1.0739
Gtop Mpa 1.259 1.31 1.3542 2.7642 5.4953 5.5117 6.3703 7.1598 7.5959
Girder Gbottom Mpa 5.7604 5.6929 5.6367 7.0703 9.9671 9.9352 9.0488 8.3023 7.9654
Total Stresses (A+B +C+D+E+F+G) (With SV Loading)
Dtop Mpa -0.173 -0.153 -0.134 0.0601 0.2844 0.3099 0.6245 0.8283 0.8761
Deck Dbottom Mpa -0.213 -0.197 -0.182 -0.03 0.1402 0.1592 0.3939 0.546 0.5817
Gtop Mpa 0.8689 0.9106 0.9513 2.2708 4.9281 4.9438 5.8578 6.6641 7.1038
Girder Gbottom Mpa 7.6677 7.6168 7.5668 8.8716 11.616 11.586 10.558 9.7682 9.4224

Max Compressive stress = 11.616 Mpa < 24 Mpa OK


Max Tensile Stress = 0.8689 Mpa >= -3.516 Mpa OK

2) Frequent Combination LC-SF2 : At day 36500


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.6515 0.5002 0.3677 -0.25 -0.148 -0.357 -2.927 -4.298 -4.517
Girder Gbottom Mpa 6.8121 6.9712 7.11 10.101 14.632 14.852 17.651 19.239 19.58

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder Gbottom Mpa 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.1) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.2) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0107 0.0201 0.1063 0.1964 0.2083 0.3559 0.4423 0.4729
Deck Dbottom Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Gtop Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Girder Gbottom Mpa 0 -0.015 -0.028 -0.173 -0.375 -0.397 -0.679 -0.843 -0.902

EPC Contractor-M/s Krishna Constructions 227


Design ch-109+720
Design of PSC Girder

F) Stresses due to Live load (Without SV) Load factor = 0.75


Dtop Mpa 0 0.0794 0.1321 0.584 0.9815 1.0358 1.3841 1.7393 1.7863
Deck Dbottom Mpa 0 0.0627 0.1044 0.4499 0.7324 0.773 1.0329 1.2979 1.333
Gtop Mpa 0 0.0627 0.1044 0.4499 0.7324 0.773 1.0329 1.2979 1.333
Girder Gbottom Mpa 0 -0.111 -0.185 -0.952 -1.871 -1.975 -2.639 -3.316 -3.406
F.1) Stresses due to Live load (With SV) Load factor = 0.75
Dtop Mpa 0 0.035 0.0712 0.4054 0.7642 0.8152 1.4416 1.8817 1.9461
Deck Dbottom Mpa 0 0.0276 0.0563 0.3123 0.5703 0.6083 1.0757 1.4042 1.4522
Gtop Mpa 0 0.0276 0.0563 0.3123 0.5703 0.6083 1.0757 1.4042 1.4522
Girder Gbottom Mpa 0 -0.049 -0.1 -0.661 -1.457 -1.554 -2.749 -3.588 -3.711

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.713 -0.713 -0.713 -0.635 -0.477 -0.477 -0.477 -0.477 -0.477
Deck Dbottom Mpa -0.875 -0.875 -0.875 -0.803 -0.652 -0.652 -0.652 -0.652 -0.652
Gtop Mpa 1.1035 1.1035 1.1035 1.1759 1.3266 1.3266 1.3266 1.3266 1.3266
Girder Gbottom Mpa -0.592 -0.592 -0.592 -0.58 -0.511 -0.511 -0.511 -0.511 -0.511
Total Stresses (A+B +C+D+E+F+G) (Without SV Loading)
Dtop Mpa -0.713 -0.623 -0.561 0.0553 0.7014 0.7676 1.2635 1.7051 1.7827
Deck Dbottom Mpa -0.875 -0.804 -0.755 -0.271 0.2267 0.2761 0.6461 0.9757 1.0336
Gtop Mpa 1.7394 1.8536 1.9438 3.7116 6.7592 6.835 8.2394 9.4083 9.9054
Girder Gbottom Mpa 6.2363 6.0685 5.9412 6.1025 7.1542 7.0124 5.246 3.7726 3.3044
Total Stresses (A+B +C+D+E+F+G) (With SV Loading)
Dtop Mpa -0.713 -0.668 -0.622 -0.123 0.4841 0.547 1.3209 1.8474 1.9424
Deck Dbottom Mpa -0.875 -0.839 -0.803 -0.409 0.0646 0.1115 0.689 1.0819 1.1528
Gtop Mpa 1.7394 1.8185 1.8956 3.574 6.597 6.6704 8.2822 9.5146 10.025
Girder Gbottom Mpa 6.2363 6.1309 6.0266 6.3936 7.5686 7.433 5.1365 3.5011 2.9998

Max Compressive stress = 10.025 Mpa < 24 Mpa OK


Max Tensile Stress = 1.7394 Mpa >= -3.516 Mpa OK

2.1) Frequent Combination LC-SF2.1 : At day 36500 + temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.6515 0.5002 0.3677 -0.25 -0.148 -0.357 -2.927 -4.298 -4.517
Girder Gbottom Mpa 6.8121 6.9712 7.11 10.101 14.632 14.852 17.651 19.239 19.58

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder Gbottom Mpa 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.1) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.2) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0107 0.0201 0.1063 0.1964 0.2083 0.3559 0.4423 0.4729
Deck Dbottom Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Gtop Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Girder Gbottom Mpa 0 -0.015 -0.028 -0.173 -0.375 -0.397 -0.679 -0.843 -0.902

EPC Contractor-M/s Krishna Constructions 228


Design ch-109+720
Design of PSC Girder

F) Stresses due to Live load (Without SV) Load factor = 0.75


Dtop Mpa 0 0.0794 0.1321 0.584 0.9815 1.0358 1.3841 1.7393 1.7863
Deck Dbottom Mpa 0 0.0627 0.1044 0.4499 0.7324 0.773 1.0329 1.2979 1.333
Gtop Mpa 0 0.0627 0.1044 0.4499 0.7324 0.773 1.0329 1.2979 1.333
Girder Gbottom Mpa 0 -0.111 -0.185 -0.952 -1.871 -1.975 -2.639 -3.316 -3.406
F.1) Stresses due to Live load (With SV) Load factor = 0.75
Dtop Mpa 0 0.035 0.0712 0.4054 0.7642 0.8152 1.4416 1.8817 1.9461
Deck Dbottom Mpa 0 0.0276 0.0563 0.3123 0.5703 0.6083 1.0757 1.4042 1.4522
Gtop Mpa 0 0.0276 0.0563 0.3123 0.5703 0.6083 1.0757 1.4042 1.4522
Girder Gbottom Mpa 0 -0.049 -0.1 -0.661 -1.457 -1.554 -2.749 -3.588 -3.711
G) Stresses due to differential shrinkage Load factor = 1
Dtop Mpa -0.713 -0.713 -0.713 -0.635 -0.477 -0.477 -0.477 -0.477 -0.477
Deck Dbottom Mpa -0.875 -0.875 -0.875 -0.803 -0.652 -0.652 -0.652 -0.652 -0.652
Gtop Mpa 1.1035 1.1035 1.1035 1.1759 1.3266 1.3266 1.3266 1.3266 1.3266
Girder Gbottom Mpa -0.592 -0.592 -0.592 -0.58 -0.511 -0.511 -0.511 -0.511 -0.511
H) +ve temperature stresses Load factor = 0.5
Dtop Mpa 2.26 2.26 2.26 2.3498 2.4404 2.4404 2.4404 2.4404 2.4404
Deck Dbottom Mpa -0.66 -0.66 -0.66 -0.598 -0.536 -0.536 -0.536 -0.536 -0.536
Gtop Mpa -0.66 -0.66 -0.66 -0.598 -0.536 -0.536 -0.536 -0.536 -0.536
Girder Gbottom Mpa 1.4029 1.4029 1.4029 1.1743 0.9436 0.9436 0.9436 0.9436 0.9436
Total Stresses (A+B +C+D+E+F+G) (Without SV Loading)
Dtop Mpa 1.5467 1.6367 1.6989 2.4051 3.1418 3.208 3.7039 4.1455 4.2231
Deck Dbottom Mpa -1.535 -1.464 -1.415 -0.869 -0.309 -0.259 0.1105 0.4401 0.498
Gtop Mpa 1.0795 1.1937 1.2839 3.1136 6.2236 6.2994 7.7038 8.8727 9.3698
Girder Gbottom Mpa 7.6392 7.4714 7.3441 7.2768 8.0978 7.9559 6.1896 4.7162 4.2479
Total Stresses (A+B +C+D+E+F+G) (With SV Loading)
Dtop Mpa -0.713 -0.668 -0.622 -0.123 0.4841 0.547 1.3209 1.8474 1.9424
Deck Dbottom Mpa -0.875 -0.839 -0.803 -0.409 0.0646 0.1115 0.689 1.0819 1.1528
Gtop Mpa 1.7394 1.8185 1.8956 3.574 6.597 6.6704 8.2822 9.5146 10.025
Girder Gbottom Mpa 6.2363 6.1309 6.0266 6.3936 7.5686 7.433 5.1365 3.5011 2.9998

Max Compressive stress = 10.025 Mpa < 24 Mpa OK


Max Tensile Stress = 1.0795 Mpa >= -3.516 Mpa OK

2.2) Frequent Combination LC-SF2.2 : At day 36500 - temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.6515 0.5002 0.3677 -0.25 -0.148 -0.357 -2.927 -4.298 -4.517
Girder Gbottom Mpa 6.8121 6.9712 7.11 10.101 14.632 14.852 17.651 19.239 19.58

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder Gbottom Mpa 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.1) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.2) Stresses due to surfacing Load factor = 1

EPC Contractor-M/s Krishna Constructions 229


Design ch-109+720
Design of PSC Girder

Dtop Mpa 0 0.0107 0.0201 0.1063 0.1964 0.2083 0.3559 0.4423 0.4729
Deck Dbottom Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Gtop Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Girder Gbottom Mpa 0 -0.015 -0.028 -0.173 -0.375 -0.397 -0.679 -0.843 -0.902
F) Stresses due to Live load (Without SV) Load factor = 0.75
Dtop Mpa 0 0.0794 0.1321 0.584 0.9815 1.0358 1.3841 1.7393 1.7863
Deck Dbottom Mpa 0 0.0627 0.1044 0.4499 0.7324 0.773 1.0329 1.2979 1.333
Gtop Mpa 0 0.0627 0.1044 0.4499 0.7324 0.773 1.0329 1.2979 1.333
Girder Gbottom Mpa 0 -0.111 -0.185 -0.952 -1.871 -1.975 -2.639 -3.316 -3.406
F.1) Stresses due to Live load (With SV) Load factor = 0.75
Dtop Mpa 0 0.035 0.0712 0.4054 0.7642 0.8152 1.4416 1.8817 1.9461
Deck Dbottom Mpa 0 0.0276 0.0563 0.3123 0.5703 0.6083 1.0757 1.4042 1.4522
Gtop Mpa 0 0.0276 0.0563 0.3123 0.5703 0.6083 1.0757 1.4042 1.4522
Girder Gbottom Mpa 0 -0.049 -0.1 -0.661 -1.457 -1.554 -2.749 -3.588 -3.711
G) Stresses due to differential shrinkage Load factor = 1
Dtop Mpa -0.713 -0.713 -0.713 -0.635 -0.477 -0.477 -0.477 -0.477 -0.477
Deck Dbottom Mpa -0.875 -0.875 -0.875 -0.803 -0.652 -0.652 -0.652 -0.652 -0.652
Gtop Mpa 1.1035 1.1035 1.1035 1.1759 1.3266 1.3266 1.3266 1.3266 1.3266
Girder Gbottom Mpa -0.592 -0.592 -0.592 -0.58 -0.511 -0.511 -0.511 -0.511 -0.511
H) -ve temperature stresses Load factor = 0.5
Dtop Mpa -1.416 -1.416 -1.416 -1.37 -1.323 -1.323 -1.323 -1.323 -1.323
Deck Dbottom Mpa 0.3251 0.3251 0.3251 0.3806 0.4366 0.4366 0.4366 0.4366 0.4366
Gtop Mpa 0.3251 0.3251 0.3251 0.3806 0.4366 0.4366 0.4366 0.4366 0.4366
Girder Gbottom Mpa -1.589 -1.589 -1.589 -1.436 -1.282 -1.282 -1.282 -1.282 -1.282
Total Stresses (A+B +C+D+E+F+G) (Without SV Loading)
Dtop Mpa -2.129 -2.039 -1.977 -1.314 -0.622 -0.555 -0.06 0.382 0.4596
Deck Dbottom Mpa -0.55 -0.479 -0.43 0.1094 0.6634 0.7128 1.0828 1.4123 1.4703
Gtop Mpa 2.0644 2.1787 2.2688 4.0922 7.1959 7.2717 8.676 9.845 10.342
Girder Gbottom Mpa 4.6469 4.4791 4.3517 4.6661 5.8723 5.7305 3.9642 2.4907 2.0225
Total Stresses (A+B +C+D+E+F+G) (With SV Loading)
Dtop Mpa -0.713 -0.668 -0.622 -0.123 0.4841 0.547 1.3209 1.8474 1.9424
Deck Dbottom Mpa -0.875 -0.839 -0.803 -0.409 0.0646 0.1115 0.689 1.0819 1.1528
Gtop Mpa 1.7394 1.8185 1.8956 3.574 6.597 6.6704 8.2822 9.5146 10.025
Girder Gbottom Mpa 6.2363 6.1309 6.0266 6.3936 7.5686 7.433 5.1365 3.5011 2.9998

Max Compressive stress = 10.342 Mpa < 24 Mpa OK


Max Tensile Stress = 1.7394 Mpa >= -3.516 Mpa OK

2.3) Frequent Combination LC-SF2.3 : At day 36500 + temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.6515 0.5002 0.3677 -0.25 -0.148 -0.357 -2.927 -4.298 -4.517
Girder Gbottom Mpa 6.8121 6.9712 7.11 10.101 14.632 14.852 17.651 19.239 19.58

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder Gbottom Mpa 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.1) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck

EPC Contractor-M/s Krishna Constructions 230


Design ch-109+720
Design of PSC Girder

Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0


Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.2) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0107 0.0201 0.1063 0.1964 0.2083 0.3559 0.4423 0.4729
Deck Dbottom Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Gtop Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Girder Gbottom Mpa 0 -0.015 -0.028 -0.173 -0.375 -0.397 -0.679 -0.843 -0.902
F) Stresses due to Live load (Without SV) Load factor = 0.2
Dtop Mpa 0 0.0212 0.0352 0.1557 0.2617 0.2762 0.3691 0.4638 0.4764
Deck Dbottom Mpa 0 0.0167 0.0278 0.12 0.1953 0.2061 0.2754 0.3461 0.3555
Gtop Mpa 0 0.0167 0.0278 0.12 0.1953 0.2061 0.2754 0.3461 0.3555
Girder Gbottom Mpa 0 -0.03 -0.049 -0.254 -0.499 -0.527 -0.704 -0.884 -0.908
F.1) Stresses due to Live load (With SV) Load factor = 0.2
Dtop Mpa 0 0.0093 0.019 0.1081 0.2038 0.2174 0.3844 0.5018 0.519
Deck Dbottom Mpa 0 0.0074 0.015 0.0833 0.1521 0.1622 0.2869 0.3744 0.3873
Gtop Mpa 0 0.0074 0.015 0.0833 0.1521 0.1622 0.2869 0.3744 0.3873
Girder Gbottom Mpa 0 -0.013 -0.027 -0.176 -0.389 -0.415 -0.733 -0.957 -0.99

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.713 -0.713 -0.713 -0.635 -0.477 -0.477 -0.477 -0.477 -0.477
Deck Dbottom Mpa -0.875 -0.875 -0.875 -0.803 -0.652 -0.652 -0.652 -0.652 -0.652
Gtop Mpa 1.1035 1.1035 1.1035 1.1759 1.3266 1.3266 1.3266 1.3266 1.3266
Girder Gbottom Mpa -0.592 -0.592 -0.592 -0.58 -0.511 -0.511 -0.511 -0.511 -0.511
H) +ve temperature stresses Load factor = 0.6
Dtop Mpa 2.712 2.712 2.712 2.8197 2.9285 2.9285 2.9285 2.9285 2.9285
Deck Dbottom Mpa -0.792 -0.792 -0.792 -0.718 -0.643 -0.643 -0.643 -0.643 -0.643
Gtop Mpa -0.792 -0.792 -0.792 -0.718 -0.643 -0.643 -0.643 -0.643 -0.643
Girder Gbottom Mpa 1.6835 1.6835 1.6835 1.4091 1.1323 1.1323 1.1323 1.1323 1.1323
Total Stresses (A+B +C+D+E+F+G) (Without SV Loading)
Dtop Mpa 1.9987 2.0305 2.054 2.4468 2.9101 2.9365 3.1769 3.3581 3.4012
Deck Dbottom Mpa -1.667 -1.642 -1.624 -1.319 -0.953 -0.933 -0.754 -0.619 -0.587
Gtop Mpa 0.9475 1.0157 1.0753 2.664 5.5794 5.6255 6.8392 7.8138 8.2851
Girder Gbottom Mpa 7.9198 7.8337 7.7606 8.2098 9.6589 9.593 8.3137 7.3368 6.9344
Total Stresses (A+B +C+D+E+F+G) (With SV Loading)
Dtop Mpa -0.713 -0.693 -0.674 -0.421 -0.076 -0.051 0.2637 0.4676 0.5153
Deck Dbottom Mpa -0.875 -0.86 -0.845 -0.638 -0.354 -0.335 -0.1 0.0522 0.0879
Gtop Mpa 1.7394 1.7983 1.8544 3.345 6.1788 6.2243 7.4933 8.4849 8.9596
Girder Gbottom Mpa 6.2363 6.1668 6.0999 6.8783 8.6371 8.5729 7.1522 6.1322 5.7209

Max Compressive stress = 9.6589 Mpa < 24 Mpa OK


Max Tensile Stress = 0.9475 Mpa >= -3.516 Mpa OK

2.4) Frequent Combination LC-SF2.4 : At day 36500 - temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.6515 0.5002 0.3677 -0.25 -0.148 -0.357 -2.927 -4.298 -4.517
Girder Gbottom Mpa 6.8121 6.9712 7.11 10.101 14.632 14.852 17.651 19.239 19.58

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder Gbottom Mpa 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck

EPC Contractor-M/s Krishna Constructions 231


Design ch-109+720
Design of PSC Girder

Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0


Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.1) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.2) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0107 0.0201 0.1063 0.1964 0.2083 0.3559 0.4423 0.4729
Deck Dbottom Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Gtop Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Girder Gbottom Mpa 0 -0.015 -0.028 -0.173 -0.375 -0.397 -0.679 -0.843 -0.902
F) Stresses due to Live load (Without SV) Load factor = 0.2
Dtop Mpa 0 0.0212 0.0352 0.1557 0.2617 0.2762 0.3691 0.4638 0.4764
Deck Dbottom Mpa 0 0.0167 0.0278 0.12 0.1953 0.2061 0.2754 0.3461 0.3555
Gtop Mpa 0 0.0167 0.0278 0.12 0.1953 0.2061 0.2754 0.3461 0.3555
Girder Gbottom Mpa 0 -0.03 -0.049 -0.254 -0.499 -0.527 -0.704 -0.884 -0.908
F.1) Stresses due to Live load (With SV) Load factor = 0.2
Dtop Mpa 0 0.0093 0.019 0.1081 0.2038 0.2174 0.3844 0.5018 0.519
Deck Dbottom Mpa 0 0.0074 0.015 0.0833 0.1521 0.1622 0.2869 0.3744 0.3873
Gtop Mpa 0 0.0074 0.015 0.0833 0.1521 0.1622 0.2869 0.3744 0.3873
Girder Gbottom Mpa 0 -0.013 -0.027 -0.176 -0.389 -0.415 -0.733 -0.957 -0.99
G) Stresses due to differential shrinkage Load factor = 1
Dtop Mpa -0.713 -0.713 -0.713 -0.635 -0.477 -0.477 -0.477 -0.477 -0.477
Deck Dbottom Mpa -0.875 -0.875 -0.875 -0.803 -0.652 -0.652 -0.652 -0.652 -0.652
Gtop Mpa 1.1035 1.1035 1.1035 1.1759 1.3266 1.3266 1.3266 1.3266 1.3266
Girder Gbottom Mpa -0.592 -0.592 -0.592 -0.58 -0.511 -0.511 -0.511 -0.511 -0.511
H) -ve temperature stresses Load factor = 0.6
Dtop Mpa -1.699 -1.699 -1.699 -1.643 -1.588 -1.588 -1.588 -1.588 -1.588
Deck Dbottom Mpa 0.3901 0.3901 0.3901 0.4567 0.524 0.524 0.524 0.524 0.524
Gtop Mpa 0.3901 0.3901 0.3901 0.4567 0.524 0.524 0.524 0.524 0.524
Girder Gbottom Mpa -1.907 -1.907 -1.907 -1.724 -1.538 -1.538 -1.538 -1.538 -1.538
Total Stresses (A+B +C+D+E+F+G) (Without SV Loading)
Dtop Mpa -2.412 -2.38 -2.357 -2.016 -1.606 -1.58 -1.339 -1.158 -1.115
Deck Dbottom Mpa -0.485 -0.46 -0.442 -0.144 0.2136 0.2333 0.4127 0.5478 0.58
Gtop Mpa 2.1295 2.1977 2.2573 3.8384 6.7461 6.7922 8.0059 8.9805 9.4518
Girder Gbottom Mpa 4.329 4.2429 4.1698 5.077 6.9884 6.9224 5.6432 4.6663 4.2639
Total Stresses (A+B +C+D+E+F+G) (With SV Loading)
Dtop Mpa -0.713 -0.693 -0.674 -0.421 -0.076 -0.051 0.2637 0.4676 0.5153
Deck Dbottom Mpa -0.875 -0.86 -0.845 -0.638 -0.354 -0.335 -0.1 0.0522 0.0879
Gtop Mpa 1.7394 1.7983 1.8544 3.345 6.1788 6.2243 7.4933 8.4849 8.9596
Girder Gbottom Mpa 6.2363 6.1668 6.0999 6.8783 8.6371 8.5729 7.1522 6.1322 5.7209

Max Compressive stress = 9.4518 Mpa < 24 Mpa OK


Max Tensile Stress = 1.7394 Mpa >= -3.516 Mpa OK

SUMMARY FOR SLS FREQUENT COMBINATION


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
1) Frequent Combination LC-SF1 : At day 92 Structure open to LL
Total Stresses (A+B)
Gtop Mpa 0.8689 0.9659 1.0407 2.6374 5.5085 5.5546 6.6038 7.5876 8.0495
Girder Gbottom Mpa 7.6677 7.5185 7.408 8.0957 10.133 10.025 8.6517 7.4086 7.0059
1.1) Frequent Combination LC-SF1.1 : At day 92 Structure open to LL + temperature stresses
Total Stresses (A+B)
Gtop Mpa 0.209 0.306 0.3808 2.0394 4.9728 5.019 6.0682 7.052 7.5139
Girder Gbottom Mpa 9.0706 8.9214 8.8109 9.27 11.077 10.969 9.5953 8.3522 7.9495
1.2) Frequent Combination LC-SF1.2 : At day 92 Structure open to LL - temperature stresses
Total Stresses (A+B)

EPC Contractor-M/s Krishna Constructions 232


Design ch-109+720
Design of PSC Girder

Gtop Mpa 1.1939 1.291 1.3657 3.018 5.9451 5.9912 7.0404 8.0242 8.4862
Girder Gbottom Mpa 6.0783 5.9291 5.8186 6.6594 8.8511 8.7433 7.3698 6.1267 5.724
1.3) Frequent Combination LC-SF1.3 : At day 92 Structure open to LL + temperature stresses
Total Stresses (A+B)
Gtop Mpa 0.077 0.1281 0.1722 1.5898 4.3286 4.345 5.2036 5.993 6.4292
Girder Gbottom Mpa 9.3512 9.2836 9.2274 10.203 12.638 12.606 11.719 10.973 10.636
1.4) Frequent Combination LC-SF1.4 : At day 92 Structure open to LL - temperature stresses
Total Stresses (A+B)
Gtop Mpa 1.259 1.31 1.3542 2.7642 5.4953 5.5117 6.3703 7.1598 7.5959
Girder Gbottom Mpa 5.7604 5.6929 5.6367 7.0703 9.9671 9.9352 9.0488 8.3023 7.9654
2) Frequent Combination LC-SF2 : At day 36500
Total Stresses (A+B)
Gtop Mpa 1.7394 1.8536 1.9438 3.7116 6.7592 6.835 8.2394 9.4083 9.9054
Girder Gbottom Mpa 6.2363 6.0685 5.9412 6.1025 7.1542 7.0124 5.246 3.7726 3.3044
2.1) Frequent Combination LC-SF2.1 : At day 36500 + temperature stresses
Total Stresses (A+B)
Gtop Mpa 1.0795 1.1937 1.2839 3.1136 6.2236 6.2994 7.7038 8.8727 9.3698
Girder Gbottom Mpa 7.6392 7.4714 7.3441 7.2768 8.0978 7.9559 6.1896 4.7162 4.2479
2.2) Frequent Combination LC-SF2.2 : At day 36500 - temperature stresses
Total Stresses (A+B)
Gtop Mpa 2.0644 2.1787 2.2688 4.0922 7.1959 7.2717 8.676 9.845 10.342
Girder Gbottom Mpa 4.6469 4.4791 4.3517 4.6661 5.8723 5.7305 3.9642 2.4907 2.0225
2.3) Frequent Combination LC-SF2.3 : At day 36500 + temperature stresses
Total Stresses (A+B)
Gtop Mpa 0.9475 1.0157 1.0753 2.664 5.5794 5.6255 6.8392 7.8138 8.2851
Girder Gbottom Mpa 7.9198 7.8337 7.7606 8.2098 9.6589 9.593 8.3137 7.3368 6.9344
2.4) Frequent Combination LC-SF2.4 : At day 36500 - temperature stresses
Total Stresses (A+B)
Gtop Mpa 2.1295 2.1977 2.2573 3.8384 6.7461 6.7922 8.0059 8.9805 9.4518
Girder Gbottom Mpa 4.329 4.2429 4.1698 5.077 6.9884 6.9224 5.6432 4.6663 4.2639

QUASI PERMANENT LOAD COMBINATION


1) QSP Combination LC-SQ1 : At day 92 Structure open to LL
Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.6164 0.4478 0.3 -0.434 -0.394 -0.633 -3.558 -5.114 -5.369
Girder Gbottom Mpa 7.7954 7.9731 8.1287 11.655 17.224 17.478 20.67 22.488 22.895

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder Gbottom Mpa 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0107 0.0201 0.1063 0.1964 0.2083 0.3559 0.4423 0.4729
Deck Dbottom Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Gtop Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Girder

EPC Contractor-M/s Krishna Constructions 233


Design ch-109+720
Design of PSC Girder

Girder Gbottom Mpa 0 -0.015 -0.028 -0.173 -0.375 -0.397 -0.679 -0.843 -0.902
F) Stresses due to Live load Load factor = 0
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.173 -0.173 -0.173 -0.154 -0.116 -0.116 -0.116 -0.116 -0.116
Deck Dbottom Mpa -0.213 -0.213 -0.213 -0.195 -0.158 -0.158 -0.158 -0.158 -0.158
Gtop Mpa 0.2681 0.2681 0.2681 0.2857 0.3223 0.3223 0.3223 0.3223 0.3223
Girder Gbottom Mpa -0.144 -0.144 -0.144 -0.141 -0.124 -0.124 -0.124 -0.124 -0.124
Total Stresses (A+B +C+D+E+F+G)
Dtop Mpa -0.173 -0.163 -0.153 -0.048 0.0807 0.0926 0.2401 0.3265 0.3571
Deck Dbottom Mpa -0.213 -0.204 -0.197 -0.113 -0.012 -0.003 0.1071 0.1716 0.1944
Gtop Mpa 0.8689 0.9032 0.9363 2.1875 4.776 4.7816 5.5709 6.2897 6.7165
Girder Gbottom Mpa 7.6677 7.6299 7.5934 9.0478 12.004 12 11.291 10.725 10.412

Max Compressive stress = 12.004 Mpa < 24 Mpa OK


Max Tensile Stress = 0.8689 Mpa >= -3.516 Mpa OK

1.1) QSP Combination LC-SQ1.1 : At day 92 Structure open to LL + temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.6164 0.4478 0.3 -0.434 -0.394 -0.633 -3.558 -5.114 -5.369
Girder Gbottom Mpa 7.7954 7.9731 8.1287 11.655 17.224 17.478 20.67 22.488 22.895

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder Gbottom Mpa 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0107 0.0201 0.1063 0.1964 0.2083 0.3559 0.4423 0.4729
Deck Dbottom Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Gtop Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Girder Gbottom Mpa 0 -0.015 -0.028 -0.173 -0.375 -0.397 -0.679 -0.843 -0.902
F) Stresses due to Live load Load factor = 0
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0

G) Stresses due to differential shrinkage Load factor = 1


Dtop Mpa -0.173 -0.173 -0.173 -0.154 -0.116 -0.116 -0.116 -0.116 -0.116
Deck Dbottom Mpa -0.213 -0.213 -0.213 -0.195 -0.158 -0.158 -0.158 -0.158 -0.158

EPC Contractor-M/s Krishna Constructions 234


Design ch-109+720
Design of PSC Girder

Gtop Mpa 0.2681 0.2681 0.2681 0.2857 0.3223 0.3223 0.3223 0.3223 0.3223
Girder Gbottom Mpa -0.144 -0.144 -0.144 -0.141 -0.124 -0.124 -0.124 -0.124 -0.124
H) +ve temperature stresses Load factor = 0.5
Dtop Mpa 2.26 2.26 2.26 2.3498 2.4404 2.4404 2.4404 2.4404 2.4404
Deck Dbottom Mpa -0.66 -0.66 -0.66 -0.598 -0.536 -0.536 -0.536 -0.536 -0.536
Gtop Mpa -0.66 -0.66 -0.66 -0.598 -0.536 -0.536 -0.536 -0.536 -0.536
Girder Gbottom Mpa 1.4029 1.4029 1.4029 1.1743 0.9436 0.9436 0.9436 0.9436 0.9436
Total Stresses (A+B +C+D+E+F+G+H)
Dtop Mpa 2.0867 2.0973 2.1068 2.3018 2.5211 2.533 2.6805 2.7669 2.7975
Deck Dbottom Mpa -0.873 -0.864 -0.857 -0.711 -0.548 -0.539 -0.429 -0.364 -0.341
Gtop Mpa 0.209 0.2433 0.2764 1.5895 4.2404 4.246 5.0353 5.7541 6.1809
Girder Gbottom Mpa 9.0706 9.0328 8.9963 10.222 12.948 12.944 12.234 11.669 11.356

Max Compressive stress = 12.948 Mpa < 24 Mpa OK


Max Tensile Stress = 0.209 Mpa >= -3.516 Mpa OK

1.2) QSP Combination LC-SQ1.2 : At day 92 Structure open to LL - temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.6164 0.4478 0.3 -0.434 -0.394 -0.633 -3.558 -5.114 -5.369
Girder Gbottom Mpa 7.7954 7.9731 8.1287 11.655 17.224 17.478 20.67 22.488 22.895

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder Gbottom Mpa 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0107 0.0201 0.1063 0.1964 0.2083 0.3559 0.4423 0.4729
Deck Dbottom Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Gtop Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Girder Gbottom Mpa 0 -0.015 -0.028 -0.173 -0.375 -0.397 -0.679 -0.843 -0.902
F) Stresses due to Live load Load factor = 0
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
G) Stresses due to differential shrinkage Load factor = 1
Dtop Mpa -0.173 -0.173 -0.173 -0.154 -0.116 -0.116 -0.116 -0.116 -0.116
Deck Dbottom Mpa -0.213 -0.213 -0.213 -0.195 -0.158 -0.158 -0.158 -0.158 -0.158
Gtop Mpa 0.2681 0.2681 0.2681 0.2857 0.3223 0.3223 0.3223 0.3223 0.3223
Girder Gbottom Mpa -0.144 -0.144 -0.144 -0.141 -0.124 -0.124 -0.124 -0.124 -0.124
H) -ve temperature stresses Load factor = 0.5
Dtop Mpa -1.416 -1.416 -1.416 -1.37 -1.323 -1.323 -1.323 -1.323 -1.323
Deck Dbottom Mpa 0.3251 0.3251 0.3251 0.3806 0.4366 0.4366 0.4366 0.4366 0.4366
Gtop Mpa 0.3251 0.3251 0.3251 0.3806 0.4366 0.4366 0.4366 0.4366 0.4366
Girder

EPC Contractor-M/s Krishna Constructions 235


Design ch-109+720
Design of PSC Girder

Girder Gbottom Mpa -1.589 -1.589 -1.589 -1.436 -1.282 -1.282 -1.282 -1.282 -1.282
Total Stresses (A+B +C+D+E+F+G+H)
Dtop Mpa -1.589 -1.578 -1.569 -1.418 -1.242 -1.231 -1.083 -0.997 -0.966
Deck Dbottom Mpa 0.1124 0.1208 0.1283 0.2674 0.4247 0.4336 0.5437 0.6082 0.6311
Gtop Mpa 1.1939 1.2283 1.2614 2.5681 5.2126 5.2183 6.0075 6.7263 7.1531
Girder Gbottom Mpa 6.0783 6.0405 6.004 7.6114 10.723 10.718 10.009 9.4431 9.1301

Max Compressive stress = 10.723 Mpa < 24 Mpa OK


Max Tensile Stress = 1.1939 Mpa >= -3.516 Mpa OK

2) QSP Combination LC-SQ2 : At day 36500


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.6515 0.5002 0.3677 -0.25 -0.148 -0.357 -2.927 -4.298 -4.517
Girder Gbottom Mpa 6.8121 6.9712 7.11 10.101 14.632 14.852 17.651 19.239 19.58

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder Gbottom Mpa 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.1) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.2) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0107 0.0201 0.1063 0.1964 0.2083 0.3559 0.4423 0.4729
Deck Dbottom Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Gtop Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Girder Gbottom Mpa 0 -0.015 -0.028 -0.173 -0.375 -0.397 -0.679 -0.843 -0.902
F) Stresses due to Live load Load factor = 0
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
G) Stresses due to differential shrinkage Load factor = 1
Dtop Mpa -0.713 -0.713 -0.713 -0.635 -0.477 -0.477 -0.477 -0.477 -0.477
Deck Dbottom Mpa -0.875 -0.875 -0.875 -0.803 -0.652 -0.652 -0.652 -0.652 -0.652
Gtop Mpa 1.1035 1.1035 1.1035 1.1759 1.3266 1.3266 1.3266 1.3266 1.3266
Girder Gbottom Mpa -0.592 -0.592 -0.592 -0.58 -0.511 -0.511 -0.511 -0.511 -0.511
Total Stresses (A+B +C+D+E+F+G)
Dtop Mpa -0.713 -0.703 -0.693 -0.529 -0.28 -0.268 -0.121 -0.034 -0.004
Deck Dbottom Mpa -0.875 -0.867 -0.86 -0.721 -0.506 -0.497 -0.387 -0.322 -0.299
Gtop Mpa 1.7394 1.7909 1.8394 3.2617 6.0268 6.0621 7.2065 8.1104 8.5724
Girder Gbottom Mpa 6.2363 6.1799 6.1266 7.0545 9.0257 8.9874 7.8852 7.0889 6.7104

Max Compressive stress = 9.0257 Mpa < 24 Mpa OK


Max Tensile Stress = 1.7394 Mpa >= -3.516 Mpa OK

EPC Contractor-M/s Krishna Constructions 236


Design ch-109+720
Design of PSC Girder

2.1) QSP Combination LC-SQ2.1 : At day 36500 + temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1
Gtop Mpa 0.6515 0.5002 0.3677 -0.25 -0.148 -0.357 -2.927 -4.298 -4.517
Girder Gbottom Mpa 6.8121 6.9712 7.11 10.101 14.632 14.852 17.651 19.239 19.58

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder Gbottom Mpa 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.1) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.2) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0107 0.0201 0.1063 0.1964 0.2083 0.3559 0.4423 0.4729
Deck Dbottom Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Gtop Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Girder Gbottom Mpa 0 -0.015 -0.028 -0.173 -0.375 -0.397 -0.679 -0.843 -0.902
F) Stresses due to Live load Load factor = 0
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
G) Stresses due to differential shrinkage Load factor = 1
Dtop Mpa -0.713 -0.713 -0.713 -0.635 -0.477 -0.477 -0.477 -0.477 -0.477
Deck Dbottom Mpa -0.875 -0.875 -0.875 -0.803 -0.652 -0.652 -0.652 -0.652 -0.652
Gtop Mpa 1.1035 1.1035 1.1035 1.1759 1.3266 1.3266 1.3266 1.3266 1.3266
Girder Gbottom Mpa -0.592 -0.592 -0.592 -0.58 -0.511 -0.511 -0.511 -0.511 -0.511
H) +ve temperature stresses Load factor = 0.5
Dtop Mpa 2.26 2.26 2.26 2.3498 2.4404 2.4404 2.4404 2.4404 2.4404
Deck Dbottom Mpa -0.66 -0.66 -0.66 -0.598 -0.536 -0.536 -0.536 -0.536 -0.536
Gtop Mpa -0.66 -0.66 -0.66 -0.598 -0.536 -0.536 -0.536 -0.536 -0.536
Girder Gbottom Mpa 1.4029 1.4029 1.4029 1.1743 0.9436 0.9436 0.9436 0.9436 0.9436
Total Stresses (A+B +C+D+E+F+G+H)
Dtop Mpa 1.5467 1.5574 1.5668 1.8211 2.1603 2.1722 2.3197 2.4062 2.4368
Deck Dbottom Mpa -1.535 -1.527 -1.519 -1.319 -1.041 -1.032 -0.922 -0.858 -0.835
Gtop Mpa 1.0795 1.131 1.1795 2.6636 5.4912 5.5265 6.6709 7.5748 8.0367
Girder Gbottom Mpa 7.6392 7.5828 7.5295 8.2288 9.9693 9.9309 8.8288 8.0325 7.654

Max Compressive stress = 9.9693 Mpa < 24 Mpa OK


Max Tensile Stress = 1.0795 Mpa >= -3.516 Mpa OK

2.2) QSP Combination LC-SQ2.2 : At day 36500 - temperature stresses


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
A) Stresses due to Prestress force Load factor = 1

EPC Contractor-M/s Krishna Constructions 237


Design ch-109+720
Design of PSC Girder

Gtop Mpa 0.6515 0.5002 0.3677 -0.25 -0.148 -0.357 -2.927 -4.298 -4.517
Girder Gbottom Mpa 6.8121 6.9712 7.11 10.101 14.632 14.852 17.651 19.239 19.58

B) Stresses due to Selfweight of girder Load factor = 1


Gtop Mpa -0.009 0.1128 0.2179 1.3038 2.6866 2.8422 4.7883 5.9559 6.3452
Girder Gbottom Mpa 0.0098 -0.116 -0.225 -1.327 -2.698 -2.854 -4.808 -5.98 -6.371

C) Stresses due to deck slab Load factor = 1


Gtop Mpa -0.006 0.066 0.1344 0.9498 2.0148 2.0944 3.7527 4.7957 5.0651
Girder Gbottom Mpa 0.0063 -0.068 -0.139 -0.967 -2.023 -2.103 -3.768 -4.815 -5.086

D) Stresses due to transfer over permanentLoad


bearings
factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.1) Stresses due to placement of SIDL Load factor = 1
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
E.2) Stresses due to surfacing Load factor = 1
Dtop Mpa 0 0.0107 0.0201 0.1063 0.1964 0.2083 0.3559 0.4423 0.4729
Deck Dbottom Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Gtop Mpa 0 0.0084 0.0159 0.0819 0.1466 0.1555 0.2656 0.3301 0.3529
Girder Gbottom Mpa 0 -0.015 -0.028 -0.173 -0.375 -0.397 -0.679 -0.843 -0.902
F) Stresses due to Live load Load factor = 0
Dtop Mpa 0 0 0 0 0 0 0 0 0
Deck Dbottom Mpa 0 0 0 0 0 0 0 0 0
Gtop Mpa 0 0 0 0 0 0 0 0 0
Girder Gbottom Mpa 0 0 0 0 0 0 0 0 0
G) Stresses due to differential shrinkage Load factor = 1
Dtop Mpa -0.713 -0.713 -0.713 -0.635 -0.477 -0.477 -0.477 -0.477 -0.477
Deck Dbottom Mpa -0.875 -0.875 -0.875 -0.803 -0.652 -0.652 -0.652 -0.652 -0.652
Gtop Mpa 1.1035 1.1035 1.1035 1.1759 1.3266 1.3266 1.3266 1.3266 1.3266
Girder Gbottom Mpa -0.592 -0.592 -0.592 -0.58 -0.511 -0.511 -0.511 -0.511 -0.511
H) -ve temperature stresses Load factor = 0.5
Dtop Mpa -1.416 -1.416 -1.416 -1.37 -1.323 -1.323 -1.323 -1.323 -1.323
Deck Dbottom Mpa 0.3251 0.3251 0.3251 0.3806 0.4366 0.4366 0.4366 0.4366 0.4366
Gtop Mpa 0.3251 0.3251 0.3251 0.3806 0.4366 0.4366 0.4366 0.4366 0.4366
Girder Gbottom Mpa -1.589 -1.589 -1.589 -1.436 -1.282 -1.282 -1.282 -1.282 -1.282
Total Stresses (A+B +C+D+E+F+G+H)
Dtop Mpa -2.129 -2.118 -2.109 -1.898 -1.603 -1.591 -1.444 -1.357 -1.327
Deck Dbottom Mpa -0.55 -0.542 -0.534 -0.34 -0.069 -0.06 0.0499 0.1144 0.1372
Gtop Mpa 2.0644 2.116 2.1645 3.6423 6.4634 6.4987 7.6431 8.5471 9.009
Girder Gbottom Mpa 4.6469 4.5905 4.5371 5.6182 7.7438 7.7055 6.6033 5.807 5.4285

Max Compressive stress = 9.009 Mpa < 24 Mpa OK


Max Tensile Stress = 2.0644 Mpa >= -3.516 Mpa OK

SUMMARY FOR SLS QUASI PERMANENT LOAD COMBINATION


Sections unit c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Distance m 0.4 0.613 0.8 2.542 4.3 4.575 8.75 12.925 17.1
1) QSP Combination LC-SQ1 : At day 92 Structure open to LL
Total Stresses (A+B)
Gtop Mpa 0.8689 0.9032 0.9363 2.1875 4.776 4.7816 5.5709 6.2897 6.7165
Girder Gbottom Mpa 7.6677 7.6299 7.5934 9.0478 12.004 12 11.291 10.725 10.412
2) QSP Combination LC-SQ2 : At day 36500
Total Stresses (A+B)
Gtop Mpa 1.7394 1.7909 1.8394 3.2617 6.0268 6.0621 7.2065 8.1104 8.5724
Girder

EPC Contractor-M/s Krishna Constructions 238


Design ch-109+720
Design of PSC Girder

Girder Gbottom Mpa 6.2363 6.1799 6.1266 7.0545 9.0257 8.9874 7.8852 7.0889 6.7104
1.1) QSP Combination LC-SQ1.1 : At day 92 Structure open to LL + temperature stresses
Total Stresses (A+B)
Gtop Mpa 0.209 0.2433 0.2764 1.5895 4.2404 4.246 5.0353 5.7541 6.1809
Girder Gbottom Mpa 9.0706 9.0328 8.9963 10.222 12.948 12.944 12.234 11.669 11.356
2.1) QSP Combination LC-SQ2.1 : At day 36500 + temperature stresses
Total Stresses (A+B)
Gtop Mpa 1.0795 1.131 1.1795 2.6636 5.4912 5.5265 6.6709 7.5748 8.0367
Girder Gbottom Mpa 7.6392 7.5828 7.5295 8.2288 9.9693 9.9309 8.8288 8.0325 7.654
1.2) QSP Combination LC-SQ1.2 : At day 92 Structure open to LL - temperature stresses
Total Stresses (A+B)
Gtop Mpa 1.1939 1.2283 1.2614 2.5681 5.2126 5.2183 6.0075 6.7263 7.1531
Girder Gbottom Mpa 6.0783 6.0405 6.004 7.6114 10.723 10.718 10.009 9.4431 9.1301
2.2) QSP Combination LC-SQ2.2 : At day 36500 - temperature stresses
Total Stresses (A+B)
Gtop Mpa 2.0644 2.116 2.1645 3.6423 6.4634 6.4987 7.6431 8.5471 9.009
Girder Gbottom Mpa 4.6469 4.5905 4.5371 5.6182 7.7438 7.7055 6.6033 5.807 5.4285

EPC Contractor-M/s Krishna Constructions 239


Design ch-109+720
Design of PSC Girder

Check for Shear Capacity outer Girder :


Design parameters
Grade of concrete fck = 50 Mpa
fcd = 0.44667 *fck = 22.3333 Mpa

Allowable Tensile Stress fctd = fctk,0.05 / gm


= 2.5 / 1.5
= 1.66667 Mpa

fyk = 500 Mpa


gs = 1.15

fyd = fyk /gs


fyd = 434.783 Mpa

fywd = 0.8 fyk /gs


fywd = 347.826 Mpa

Summary of Shear Forces


Section At Unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7 LC-1
Precast Beam T -0 43.7076 42.8055 35.4691 30.23 29.5805 19.7204 9.86018 -4E-15 1.35
Deck Outer Girder T 1.69049 28.5496 28.2408 25.3636 22.46 22.0058 15.1101 8.2145 1.31887 1.35
Brg. Transfer T 0 0 0 0 0 0 0 0 0 1.35
SIDL T 0 7.964 8.249 8.697 7.796 6.147 4.324 4.5 2.501 1.35
Surfacing T 0 7.917 7.816 7.542 6.704 6.018 5.415 3.453 1.531 1.75
FP DL
FP LL
Wind Load T 0 7.795 7.695 7.425 6.601 5.926 5.332 3.4 1.507 0.9
Live Load T 0 59.6309 59.6131 56.4572 51.4789 46.7145 37.1936 27.862 24.6676 1.5

Shear Force at Precast Section alone Tm 2.28216 97.5473 95.9124 82.1242 71.1315 69.6415 47.0212 24.4008 1.78047
Additional Shear Force at Composite section Tm 0 121.068 121.159 116.308 105.416 94.2351 75.9028 56.9708 44.4132

Moment corresponding to Maximum Shear


Section At Unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7 Load factor
Precast Beam Tm -0 -0.0543 -0.7297 8.68949 16.7785 84.6457 142.077 150.301 253.216 314.966 335.549 1.35
Deck Outer Girder Tm -0.0398 0.1364 -0.1294 7.34724 12.2524 56.1694 97.4934 102.3 184.622 235.668 252.239 1.35

EPC Contractor-M/s Krishna Constructions 240


Design ch-109+720
Design of PSC Girder

Transfer brg. Tm 0 0 0 0 0 0 0 0 0 0 0 1.35


SIDL Tm 0 0 0 0 0 0 0 0 0 0 0 1.35
Surfacing Tm 0 0 0 1.672 3.079 15.56 27.248 28.893 49.39 61.68 65.678 1.75
FP DL
FP LL
Wind Load Tm 0 0 0 1.646 3.032 15.321 26.828 28.448 48.63 60.731 64.668 0.9
Live Load Tm 0 0 0 10.965 21.4709 114.621 202.816 224.673 358.408 423.907 463.546 1.5

Moment applied at Beam section only Tm -0.0538 0.11087 -1.1597 21.6496 39.1917 190.1 323.42 341.011 591.081 743.356 793.513
Moment applied at Composite section Tm 0 0 0 20.8549 40.3234 212.951 376.053 413.176 667.811 798.458 868.457

Section At Unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
Area of prestressing steel Ap mm2 7699.38 7699.38 7699.38 7699.38 7699.38 7699.38 7699.38 7699.38 7699.38
Cg. of prestressing force (from deck top) m 1.46085 1.47727 1.49162 1.61405 1.7189 1.73504 1.93061 2.03054 2.04431

Forces to Prestress at day = 36500


Axial force Mpa 790.003 790.323 790.553 780.599 758.577 759.148 770.548 781.621 787.944
Moment Mpa 259.523 272.601 284.027 370.076 433.336 445.915 603.312 690.083 706.522
Stresses due to Prestress force at girder Top/Bottom fibers (After all Losses ) at day = 36500
At Girder top Mpa 0.72391 0.55574 0.40857 -0.2775 -0.1644 -0.3962 -3.2519 -4.7755 -5.0194
At girder bottom Mpa 7.56899 7.74577 7.89995 11.2238 16.2578 16.5027 19.6119 21.3767 21.7557

Precast Section Property


Section At Unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
Area m2 1.92971 1.92971 1.92971 1.43945 0.94469 0.94469 0.94469 0.94469 0.94469
b m 0.825 0.825 0.825 0.55126 0.275 0.275 0.275 0.275 0.275
Iz m4 0.87202 0.87202 0.87202 0.74007 0.60691 0.60691 0.60691 0.60691 0.60691
yGB m -1.1677 -1.1677 -1.1677 -1.16 -1.1524 -1.1524 -1.1524 -1.1524 -1.1524
yGT m 1.13234 1.13234 1.13234 1.13996 1.14765 1.14765 1.14765 1.14765 1.14765
Ayp m3 0.48196 0.48196 0.48196 0.35357 0.22401 0.22401 0.22401 0.22401 0.22401

EPC Contractor-M/s Krishna Constructions 241


Design ch-109+720
Design of PSC Girder

Composite Section Property


Section At Unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
Area m2 2.50251 2.50251 2.50251 2.01225 1.51748 1.51748 1.51748 1.51748 1.51748
b m 0.825 0.825 0.825 0.55126 0.275 0.275 0.275 0.275 0.275
Iz m4 1.55604 1.55604 1.55604 1.36551 1.17322 1.17322 1.17322 1.17322 1.17322
yGB m -1.452 -1.452 -1.452 -1.5391 -1.6271 -1.6271 -1.6271 -1.6271 -1.6271
yDT m 1.06798 1.06798 1.06798 0.98086 0.89293 0.89293 0.89293 0.89293 0.89293
yGT m 0.84798 0.84798 0.84798 0.76086 0.67293 0.67293 0.67293 0.67293 0.67293
Ayc m3 0.8697 0.8697 0.8697 0.7344 0.59786 0.59786 0.59786 0.59786 0.59786

Stress due to Moment applied at Prescast section only


Section At Unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
At deck top Mpa
At deck bottom/ girder bottom Mpa -0.0151 0.28113 0.50892 2.9282 6.1158 6.44844 11.1772 14.0567 15.0052
At girder bottom Mpa 0.01553 -0.2899 -0.5248 -2.9798 -6.1409 -6.4749 -11.223 -14.114 -15.067

Stress due to Moment applied at composite section


Section At Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
At deck top Mpa 0 0.14314 0.27676 1.52965 2.86211 3.14465 5.08266 6.077 6.60975
At deck bottom/ girder bottom Mpa 0 0.11365 0.21975 1.18656 2.15694 2.36987 3.83039 4.57975 4.98124
At girder bottom Mpa 0 -0.1946 -0.3763 -2.4003 -5.2152 -5.7301 -9.2615 -11.073 -12.044

Total stress at section due to Pre-stresss force + Moment applied


Section At Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
At deck top Mpa 0 0.14314 0.27676 1.52965 2.86211 3.14465 5.08266 6.077 6.60975
At deck bottom Mpa 0 0.11365 0.21975 1.18656 2.15694 2.36987 3.83039 4.57975 4.98124
At girder top Mpa 0.70885 0.95052 1.13724 3.83721 8.10837 8.42212 11.7558 13.861 14.967
At girder bottom Mpa 7.58452 7.26126 6.99888 5.84368 4.9017 4.29773 -0.8726 -3.811 -5.355

Comparing with Allowable Tensile Stress UncrackedUncrackedUncrackedUncrackedUncrackedUncrackedUncrackedCracked Cracked

EPC Contractor-M/s Krishna Constructions 242


Design ch-109+720
Design of PSC Girder

Assuming Section Uncracked in Flexure


Vc1 = Ultimate design SF acting on the precast section alone
Vc1' = Net design shear force on precast section after deducting vertical component of pre-stress force
= Vc1 - 0.8*Vertical component of pre-stress force
*0.8 is the partial safety factor applied to prestress force
fctd = Allowable principle tensile stress = 1.66667 Mpa

scp = Compressive stress at composite centroid due to pre-stress


scm = Stresses at composite centroid due to moment Mcp
MPC = Ultimate design Moment acting on the precast section alone
s = Total stresses at coposite centroid to be used in eq-1
= 0.8scp + scm

tS = Shear-stress at composite section due to VC1'


= Vc1' * (Ay)P / ( IP * b)

IP = Second moment of area of pre-cast section alone


IC = Second moment of area of composite section
bw = web thickness
(Ay)P = First moment of area above composite centroid for pre-cast section alone
(Ay)c = First moment of area above composite centroid for composite section
Vc2 = Additional shear force which can be carried by the composite section.
= ( Ic b )
( Ay )c * √( fctd2 + fctd * s ) - ts ]

EPC Contractor-M/s Krishna Constructions 243


Design ch-109+720
Design of PSC Girder

Section At Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7

Shear Force at Precast section alone Vc1 Tonne 97.5473 95.9124 82.1242 71.1315 69.6415 47.0212 24.4008 1.78047
Vertical Component of prestress force Tonne 57.9354 57.9528 50.7239 42.174 41.0991 24.9221 8.70733 0
Vc1' Tonne 51.1989 49.5502 41.545 37.3923 36.7623 27.0835 17.435 1.78047
tS Mpa 0.343 0.33195 0.36006 0.50186 0.49341 0.3635 0.234 0.0239
Check tS ≤ fctd OK OK OK OK OK OK OK OK
Stress at composite centriod due to Moment at Precast section alone
Moment at precast section MPC 21.6496 39.1917 190.1 323.42 341.011 591.081 743.356 793.513
Stress at composite centriod scm Mpa 0.0706 0.1278 0.9738 2.52976 2.66736 4.6234 5.81447 6.2068

Stress at composite centriod due to Prestress force


scp Mpa 3.20662 3.17056 3.52717 4.6404 4.54805 3.43758 2.87608 2.81442
Total stresses at coposite centroid
s = 0.8scp + scm Mpa 2.63589 2.66425 3.79553 6.24209 6.3058 7.37346 8.11534 8.45834
Vc2 Tonne 344.642 347.573 272.355 168.843 170.087 189.855 205.269 220.395
Shear Capacity Vco = Vc1 + Vc2 Tonne 442.189 443.485 354.479 239.975 239.729 236.877 229.67 222.176

Factored shear force VED Tonne 218.615 217.072 198.432 176.547 163.877 122.924 81.3716 46.1937

Check Provide Minimum


Provide Minimum
Shear
Provide
Reinforcement
Minimum
Shear
Provide
Reinforcement
Minimum
Shear
Provide
Reinforcement
Minimum
Shear
Provide
Reinforcement
Minimum
Shear
NA Reinforcement
Shear
NA Reinforcement

Shear Capacity Assuming Section is Cracked :


Design Shear Resitance
VRdc = Max ( 0.12 k (80 r1 fck )0.33 + 0.15 scp ) bw d ( IRC 112 / clause 10.3.2 (2) )
(nmin +0.15scp ) bw d

d = 0.9 * overall depth


= 2.268 m

EPC Contractor-M/s Krishna Constructions 244


Design ch-109+720
Design of PSC Girder

2.60362
k = Min 1 + √ 200/d d is depth in mm
2 1 0.22
= 1.29696
0.175
0.075
r1 = Min Asl /bw d
0.02 0.18125 2.52
0.275 1.675 2.3
Asl provided 16 f 5 Nos. NA
Asl provided = 1005.31 mm2 0.1375

bw = 0.275 m 0.175
r1 = 0.00161 0.2

scp = Mean compressive stress 0.825


= Min [ NED/ Ac , 0.2 fcd ]

nmin = 0.031 k3/2 fck1/2


= 0.21638

EPC Contractor-M/s Krishna Constructions 245


Design ch-109+720
Design of PSC Girder

Section At Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
Prestressing Force after all losses Tonne 0 0 790.003 790.323 790.553 780.599 758.577 759.148 770.548 781.621 787.944
Area of precast section m2 0 0 1.92971 1.92971 1.92971 1.43945 0.94469 0.94469 0.94469 0.94469 0.94469
Area of composite section m2 0 0 2.50251 2.50251 2.50251 2.01225 1.51748 1.51748 1.51748 1.51748 1.51748

bw m 0.825 0.825 0.825 0.825 0.825 0.55126 0.275 0.275 0.275 0.275 0.275
Asl provided mm2 1005.31 1005.31 1005.31 1005.31 1005.31 1005.31 1005.31 1005.31 1005.31 1005.31 1005.31

r1 0.00054 0.00054 0.00054 0.0008 0.00161 0.00161 0.00161 0.00161 0.00161


scp Mpa 4.0939 4.09555 4.09675 4.46667 4.46667 4.46667 4.46667 4.46667 4.46667
VRd.c Tonne 155.389 155.436 155.469 110.82 59.7426 59.7426 59.7426 59.7426 59.7426

Factored shear force Tonne 0 218.615 217.072 198.432 176.547 163.877 122.924 81.3716 46.1937

Check NA NA NA NA NA NA NA Shear Reinf.


Provide
Required
Minimum Shear Reinforcement

CHECK FOR SECTION MAXIMUM SHEAR CAPACITY :


Vccd = 0T
Vtd = 0T

VNS = VED' -Vccd -Vtd


VNS = VED'

Variation of q 45 o ≥ q ≥ 21.8014 o

Considering q = 45 o for maximum shear capacity of section

VRdmax = acw * bw * z * n1 * fcd / ( cot q +tan q) ( IRC 112 / clause 10.3.3.2 Eq 10.8 )

acw = 1

n1 = 0.6 for fck ≤ 80 Mpa

EPC Contractor-M/s Krishna Constructions 246


Design ch-109+720
Design of PSC Girder

= Max 0.9- fck/250 for fck > 80 Mpa


0.5

= 0.6

Section At Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7

scp = NED/ Ac Mpa 4.09675 5.4229 8.02993 8.03597 8.15665 8.27386 8.34079
acw 1.18344 1.24282 1.25 1.25 1.25 1.25 1.25
bw m 0.825 0.55126 0.275 0.275 0.275 0.275 0.275
z m 1.61841 1.74084 1.84569 1.86183 2.0574 2.15733 2.1711
VRdmax 2117.35 1598.18 850.17 857.604 947.692 993.718 1000.07
Factored shear force VNS Tonne 217.072 198.432 176.547 163.877 122.924 81.3716 46.1937
Check OK OK OK OK OK OK OK

EPC Contractor-M/s Krishna Constructions 247


Design ch-109+720
Design of PSC Girder

FINDING VALUE OF q AT DESIGN SECTIONS FOR DESIGN SHEAR REINFORCEMENT


VRdmax= VNS

q = 0.5 sin-1 [ 2*VNS / (acw * bw * z * v1 * fcd) ] ( IRC 112 / clause 10.3.3.2 Eq 10.8 )

Section At Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
VNS T 217.072 198.432 176.547 163.877 122.924 81.3716 46.1937
bw m 0.825 0.55126 0.275 0.275 0.275 0.275 0.275
d m 2.268 2.268 2.268 2.268 2.268 2.268 2.268
z m 1.61841 1.74084 1.84569 1.86183 2.0574 2.15733 2.1711
q deg 5.91596 7.18913 12.2698 11.2342 7.51775 4.71295 2.65031
q adopted deg 45 21.8 21.8 21.8 21.8 21.8 21.8

FINDING DESIGN SHEAR REINFORCEMENT REQUIREMENT

VNS = VRds = (Asw/s) *z *fywd *cotq ( IRC 112 / clause 10.3.3.2 Eq 10.7 )

Asw/s = VNS / z fywd cotq

Minimum shear reinforcement ( IRC 112 / clause 10.3.3.5 Eq 10.20 )


Asw, min
= rw,min * s * bw

rw, min= ( 0.072 √ fck ) / fyk


= 0.00102

EPC Contractor-M/s Krishna Constructions 248


Design ch-109+720
Design of PSC Girder

Section At Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
VNS T 217.072 198.432 176.547 163.877 122.924 81.3716 46.1937
bw m 0.825 0.55126 0.275 0.275 0.275 0.275 0.275
z m 1.61841 1.74084 1.84569 1.86183 2.0574 2.15733 2.1711
qdesign deg 45 21.8 21.8 21.8 21.8 21.8 21.8
Asw/s mm2/m 3856.14 1310.75 1099.94 1012.15 687.043 433.734 244.663
Additional requirement (suspension reinf)
Asw,min /s mm2/m 84.0043 56.1309 28.0014 28.0014 28.0014 28.0014 28.0014
Provide Asw Legs nos 4 4 2 2 2 2 2
dia mm 12 12 12 12 12 12 12
spacing mm 100 100 100 100 100 100 100
Asw/s provide 4523.89 4523.89 2261.95 2261.95 2261.95 2261.95 2261.95
Check Ok/Revise OK OK OK OK OK OK OK

EPC Contractor-M/s Krishna Constructions 249


Design ch-109+720
Design of PSC Girder

Check for Shear Capacity Inner Girder :


Design parameters
Grade of concrete fck = 50 Mpa
fcd = 0.44667 *fck = 22.3333 Mpa

Allowable Tensile Stress fctd = fctk,0.05 / gm


= 2.5 / 1.5
= 1.66667 Mpa

fyk = 500 Mpa


gs = 1.15

fyd = fyk /gs


fyd = 434.783 Mpa

fywd = 0.8 fyk /gs


fywd = 347.826 Mpa

Summary of Shear Forces


Section At Unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7 LC-1
Precast Beam T -0 43.7076 42.8055 35.4691 30.23 29.5805 19.7204 9.86018 -4E-15 1.35
Deck Outer Girder T 3.04314 32.344 32.0071 28.8683 25.7008 25.2053 17.6828 10.1602 2.63773 1.35
Brg. Transfer T 0 0 0 0 0 0 0 0 0 1.35
SIDL T 0 4.033 4.04 4.054 4.139 4.286 4.438 4.603 0.042 1.35
Surfacing T 0 7.94 7.838 7.564 6.723 6.03 5.423 3.393 1.527 1.75
FP DL
FP LL
Wind Load T 0 7.817 7.718 7.447 6.619 5.937 5.339 3.341 1.503 0.9
Live Load T 0 64.0726 63.0992 54.1935 43.4151 40.5993 26.5316 23.2897 19.833 1.5

Shear Force at Precast Section alone Tm 4.10823 102.67 100.997 86.8556 75.5065 73.9608 50.4942 27.0276 3.56094
Additional Shear Force at Composite section Tm 0 122.484 120.766 106.703 88.4326 82.5808 60.0841 50.0933 33.8311

Moment corresponding to Maximum Shear


Section At Unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7 Load factor
Precast Beam Tm -0 -0.0543 -0.7297 8.68949 16.7785 84.6457 142.077 150.301 253.216 314.966 335.549 1.35
Deck Outer Girder Tm -0.0434 -0.0787 -0.4733 5.08272 10.3513 61.6617 106.551 110.758 198.453 253.611 267.858 1.35

EPC Contractor-M/s Krishna Constructions 250


Design ch-109+720
Design of PSC Girder

Transfer brg. Tm 0 0 0 0 0 0 0 0 0 0 0 1.35


SIDL Tm 0 0 0 0 0 0 0 0 0 0 0 1.35
Surfacing Tm 0 0 0 1.633 3.079 15.582 27.288 28.941 49.434 61.442 65.692 1.75
FP DL
FP LL
Wind Load Tm 0 0 0 1.608 3.031 15.343 26.868 28.495 48.674 60.497 64.681 0.9
Live Load Tm 0 0 0 16.1793 26.9292 114.157 181.791 191.846 256.361 322.14 330.852 1.5

Moment applied at Beam section only Tm -0.0586 -0.1795 -1.6241 18.5925 36.6251 197.515 335.647 352.429 609.754 767.578 814.599
Moment applied at Composite section Tm 0 0 0 28.5739 48.5099 212.313 344.622 364.061 514.857 645.181 669.452

Section At Unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
Area of prestressing steel Ap mm2 7699.38 7699.38 7699.38 7699.38 7699.38 7699.38 7699.38 7699.38 7699.38
Cg. of prestressing force (from deck top) m 1.46085 1.47727 1.49162 1.61405 1.7189 1.73504 1.93061 2.03054 2.04431

Forces to Prestress at day = 36500


Axial force Mpa 790.003 790.323 790.553 780.599 758.577 759.148 770.548 781.621 787.944
Moment Mpa 259.523 272.601 284.027 370.076 433.336 445.915 603.312 690.083 706.522
Stresses due to Prestress force at girder Top/Bottom fibers (After all Losses ) at day = 36500
At Girder top Mpa 0.72391 0.55574 0.40857 -0.2775 -0.1644 -0.3962 -3.2519 -4.7755 -5.0194
At girder bottom Mpa 7.56899 7.74577 7.89995 11.2238 16.2578 16.5027 19.6119 21.3767 21.7557

Precast Section Property


Section At Unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
Area m2 1.92971 1.92971 1.92971 1.43945 0.94469 0.94469 0.94469 0.94469 0.94469
b m 0.825 0.825 0.825 0.55126 0.275 0.275 0.275 0.275 0.275
Iz m4 0.87202 0.87202 0.87202 0.74007 0.60691 0.60691 0.60691 0.60691 0.60691
yGB m -1.1677 -1.1677 -1.1677 -1.16 -1.1524 -1.1524 -1.1524 -1.1524 -1.1524
yGT m 1.13234 1.13234 1.13234 1.13996 1.14765 1.14765 1.14765 1.14765 1.14765
Ayp m3 0.48196 0.48196 0.48196 0.35357 0.22401 0.22401 0.22401 0.22401 0.22401

EPC Contractor-M/s Krishna Constructions 251


Design ch-109+720
Design of PSC Girder

Composite Section Property


Section At Unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
Area m2 2.50251 2.50251 2.50251 2.01225 1.51748 1.51748 1.51748 1.51748 1.51748
b m 0.825 0.825 0.825 0.55126 0.275 0.275 0.275 0.275 0.275
Iz m4 1.55604 1.55604 1.55604 1.36551 1.17322 1.17322 1.17322 1.17322 1.17322
yGB m -1.452 -1.452 -1.452 -1.5391 -1.6271 -1.6271 -1.6271 -1.6271 -1.6271
yDT m 1.06798 1.06798 1.06798 0.98086 0.89293 0.89293 0.89293 0.89293 0.89293
yGT m 0.84798 0.84798 0.84798 0.76086 0.67293 0.67293 0.67293 0.67293 0.67293
Ayc m3 0.8697 0.8697 0.8697 0.7344 0.59786 0.59786 0.59786 0.59786 0.59786

Stress due to Moment applied at Prescast section only


Section At Unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
At deck top Mpa
At deck bottom/ girder bottom Mpa -0.0211 0.24143 0.47559 3.04241 6.34701 6.66436 11.5303 14.5147 15.4039
At girder bottom Mpa 0.02175 -0.249 -0.4904 -3.096 -6.373 -6.6917 -11.578 -14.574 -15.467

Stress due to Moment applied at composite section


Section At Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
At deck top Mpa 0 0.19612 0.33295 1.52506 2.62289 2.77084 3.91854 4.91042 5.09514
At deck bottom/ girder bottom Mpa 0 0.15572 0.26436 1.183 1.97666 2.08816 2.95309 3.70059 3.8398
At girder bottom Mpa 0 -0.2666 -0.4527 -2.3931 -4.7794 -5.0489 -7.1402 -8.9476 -9.2842

Total stress at section due to Pre-stresss force + Moment applied


Section At Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
At deck top Mpa 0 0.19612 0.33295 1.52506 2.62289 2.77084 3.91854 4.91042 5.09514
At deck bottom Mpa 0 0.15572 0.26436 1.183 1.97666 2.08816 2.95309 3.70059 3.8398
At girder top Mpa 0.70282 0.95288 1.14852 3.94787 8.15931 8.35633 11.2315 13.4399 14.2243
At girder bottom Mpa 7.59073 7.23017 6.95686 5.73465 5.10543 4.76207 0.89411 -2.1452 -2.9955

Comparing with Allowable Tensile Stress UncrackedUncrackedUncrackedUncrackedUncrackedUncrackedUncrackedCracked Cracked

EPC Contractor-M/s Krishna Constructions 252


Design ch-109+720
Design of PSC Girder

Assuming Section Uncracked in Flexure


Vc1 = Ultimate design SF acting on the precast section alone
Vc1' = Net design shear force on precast section after deducting vertical component of pre-stress force
= Vc1 - 0.8*Vertical component of pre-stress force
*0.8 is the partial safety factor applied to prestress force
fctd = Allowable principle tensile stress = 1.66667 Mpa

scp = Compressive stress at composite centroid due to pre-stress


scm = Stresses at composite centroid due to moment Mcp
MPC = Ultimate design Moment acting on the precast section alone
s = Total stresses at coposite centroid to be used in eq-1
= 0.8scp + scm

tS = Shear-stress at composite section due to VC1'


= Vc1' * (Ay)P / ( IP * b)

IP = Second moment of area of pre-cast section alone


IC = Second moment of area of composite section
bw = web thickness
(Ay)P = First moment of area above composite centroid for pre-cast section alone
(Ay)c = First moment of area above composite centroid for composite section
Vc2 = Additional shear force which can be carried by the composite section.
= ( Ic b )
( Ay )c * √( fctd2 + fctd * s ) - ts ]

EPC Contractor-M/s Krishna Constructions 253


Design ch-109+720
Design of PSC Girder

Section At Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7

Shear Force at Precast section alone Vc1 Tonne 102.67 100.997 86.8556 75.5065 73.9608 50.4942 27.0276 3.56094
Vertical Component of prestress force Tonne 57.9354 57.9528 50.7239 42.174 41.0991 24.9221 8.70733 0
Vc1' Tonne 56.3214 54.6347 46.2764 41.7674 41.0816 30.5565 20.0617 3.56094
tS Mpa 0.37732 0.36602 0.40106 0.56058 0.55138 0.41012 0.26926 0.04779
Check tS ≤ fctd OK OK OK OK OK OK OK OK
Stress at composite centriod due to Moment at Precast section alone
Moment at precast section MPC 18.5925 36.6251 197.515 335.647 352.429 609.754 767.578 814.599
Stress at composite centriod scm Mpa 0.06063 0.11943 1.01178 2.6254 2.75668 4.76945 6.00394 6.37174

Stress at composite centriod due to Prestress force


scp Mpa 3.20662 3.17056 3.52717 4.6404 4.54805 3.43758 2.87608 2.81442
Total stresses at coposite centroid
s = 0.8scp + scm Mpa 2.62592 2.65588 3.83351 6.33773 6.39512 7.51952 8.3048 8.62327
Vc2 Tonne 339.118 342.162 269.225 166.855 168.057 189.025 205.467 220.904
Shear Capacity Vco = Vc1 + Vc2 Tonne 441.788 443.158 356.081 242.362 242.018 239.519 232.495 224.465

Factored shear force VED Tonne 225.153 221.762 193.558 163.939 156.542 110.578 77.1209 37.3921

Check Provide Minimum


Provide Minimum
Shear
Provide
Reinforcement
Minimum
Shear
Provide
Reinforcement
Minimum
Shear
Provide
Reinforcement
Minimum
Shear
Provide
Reinforcement
Minimum
Shear
NA Reinforcement
Shear
NA Reinforcement

Shear Capacity Assuming Section is Cracked :


Design Shear Resitance
VRdc = Max ( 0.12 k (80 r1 fck )0.33 + 0.15 scp ) bw d ( IRC 112 / clause 10.3.2 (2) )
(nmin +0.15scp ) bw d

d = 0.9 * overall depth


= 2.268 m

EPC Contractor-M/s Krishna Constructions 254


Design ch-109+720
Design of PSC Girder

2.60362
k = Min 1 + √ 200/d d is depth in mm
2 1 0.22
= 1.29696
0.175
0.075
r1 = Min Asl /bw d
0.02 0.18125 2.52
0.275 1.675 2.3
Asl provided 16 f 5 Nos. NA
Asl provided = 1005.31 mm2 0.1375

bw = 0.275 m 0.175
r1 = 0.00161 0.2

scp = Mean compressive stress 0.825


= Min [ NED/ Ac , 0.2 fcd ]

nmin = 0.031 k3/2 fck1/2


= 0.21638

EPC Contractor-M/s Krishna Constructions 255


Design ch-109+720
Design of PSC Girder

Section At Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
Prestressing Force after all losses Tonne 0 0 790.003 790.323 790.553 780.599 758.577 759.148 770.548 781.621 787.944
Area of precast section m2 0 0 1.92971 1.92971 1.92971 1.43945 0.94469 0.94469 0.94469 0.94469 0.94469
Area of composite section m2 0 0 2.50251 2.50251 2.50251 2.01225 1.51748 1.51748 1.51748 1.51748 1.51748

bw m 0.825 0.825 0.825 0.825 0.825 0.55126 0.275 0.275 0.275 0.275 0.275
Asl provided mm2 1005.31 1005.31 1005.31 1005.31 1005.31 1005.31 1005.31 1005.31 1005.31 1005.31 1005.31

r1 0.00054 0.00054 0.00054 0.0008 0.00161 0.00161 0.00161 0.00161 0.00161


scp Mpa 4.0939 4.09555 4.09675 4.46667 4.46667 4.46667 4.46667 4.46667 4.46667
VRd.c Tonne 155.389 155.436 155.469 110.82 59.7426 59.7426 59.7426 59.7426 59.7426

Factored shear force Tonne 0 225.153 221.762 193.558 163.939 156.542 110.578 77.1209 37.3921

Check NA NA NA NA NA NA NA Shear Reinf.


Provide
Required
Minimum Shear Reinforcement

CHECK FOR SECTION MAXIMUM SHEAR CAPACITY :


Vccd = 0T
Vtd = 0T

VNS = VED' -Vccd -Vtd


VNS = VED'

Variation of q 45 o ≥ q ≥ 21.8014 o

Considering q = 45 o for maximum shear capacity of section

VRdmax = acw * bw * z * n1 * fcd / ( cot q +tan q) ( IRC 112 / clause 10.3.3.2 Eq 10.8 )

acw = 1

n1 = 0.6 for fck ≤ 80 Mpa

EPC Contractor-M/s Krishna Constructions 256


Design ch-109+720
Design of PSC Girder

= Max 0.9- fck/250 for fck > 80 Mpa


0.5

= 0.6

Section At Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7

scp = NED/ Ac Mpa 4.09675 5.4229 8.02993 8.03597 8.15665 8.27386 8.34079
acw 1.18344 1.24282 1.25 1.25 1.25 1.25 1.25
bw m 0.825 0.55126 0.275 0.275 0.275 0.275 0.275
z m 1.61841 1.74084 1.84569 1.86183 2.0574 2.15733 2.1711
VRdmax 2117.35 1598.18 850.17 857.604 947.692 993.718 1000.07
Factored shear force VNS Tonne 221.762 193.558 163.939 156.542 110.578 77.1209 37.3921
Check OK OK OK OK OK OK OK

EPC Contractor-M/s Krishna Constructions 257


Design ch-109+720
Design of PSC Girder

FINDING VALUE OF q AT DESIGN SECTIONS FOR DESIGN SHEAR REINFORCEMENT


VRdmax = VNS

q = 0.5 sin-1 [ 2*VNS / (acw * bw * z * v1 * fcd) ] ( IRC 112 / clause 10.3.3.2 Eq 10.8 )

Section At Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
VNS T 221.762 193.558 163.939 156.542 110.578 77.1209 37.3921
bw m 0.825 0.55126 0.275 0.275 0.275 0.275 0.275
d m 2.268 2.268 2.268 2.268 2.268 2.268 2.268
z m 1.61841 1.74084 1.84569 1.86183 2.0574 2.15733 2.1711
q deg 6.04571 7.0089 11.3424 10.7059 6.74759 4.46468 2.14427
q adopted deg 45 21.8 21.8 21.8 21.8 21.8 21.8

FINDING DESIGN SHEAR REINFORCEMENT REQUIREMENT

VNS = VRds = (Asw/s) *z *fywd *cotq ( IRC 112 / clause 10.3.3.2 Eq 10.7 )

Asw/s = VNS / z fywd cotq

Minimum shear reinforcement ( IRC 112 / clause 10.3.3.5 Eq 10.20 )


Asw, min = rw,min * s * bw

rw, min = ( 0.072 √ fck ) / fyk


= 0.00102

EPC Contractor-M/s Krishna Constructions 258


Design ch-109+720
Design of PSC Girder

Section At Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
VNS T 221.762 193.558 163.939 156.542 110.578 77.1209 37.3921
bw m 0.825 0.55126 0.275 0.275 0.275 0.275 0.275
z m 1.61841 1.74084 1.84569 1.86183 2.0574 2.15733 2.1711
qdesign deg 45 21.8 21.8 21.8 21.8 21.8 21.8
Asw/s mm2/m 3939.47 1278.55 1021.39 966.846 618.041 411.077 198.046
Additional requirement (suspension reinf)
Asw,min /s mm2/m 84.0043 56.1309 28.0014 28.0014 28.0014 28.0014 28.0014
Provide Asw Legs nos 4 4 2 2 2 2 2
dia mm 12 12 12 12 12 12 12
spacing mm 100 100 100 100 100 100 100
Asw/s provide 4523.89 4523.89 2261.95 2261.95 2261.95 2261.95 2261.95
Check Ok/Revise OK OK OK OK OK OK OK

EPC Contractor-M/s Krishna Constructions 259


Design ch-109+720
Design of PSC Girder

CONTROL OF SHEAR WITHIN WEBS :


Concrete Tensile stress prior to cracking in biaxial state
fctb = (1 - 0.8 s3/fck) fctk,0.05

fck = 50 Mpa
fctk,0.05 = 2.5 Mpa

Summary of Shear Forces


Section At unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7 LC-1
Precast Beam T -0 43.7076 42.8055 35.4691 30.23 29.5805 19.7204 9.86018 -4E-15 1
Deck Outer Girder T 1.69049 28.5496 28.2408 25.3636 22.46 22.0058 15.1101 8.2145 1.31887 1
Brg. Transfer T 0 0 0 0 0 0 0 0 0 1
SIDL T 0 7.964 8.249 8.697 7.796 6.147 4.324 4.5 2.501 1
Surfacing T 0 7.917 7.816 7.542 6.704 6.018 5.415 3.453 1.531 1
FP DL
FP LL
Wind Load T 0 7.795 7.695 7.425 6.601 5.926 5.332 3.4 1.507 0.6
Live Load T 0 59.6309 59.6131 56.4572 51.4789 46.7145 37.1936 27.862 24.6676 1

Shear Force at precast section alone Tm 1.69049 72.2572 71.0462 60.8327 52.69 51.5863 34.8305 18.0747 1.31887
Additional Shear Force at Composite section Tm 0 80.1889 80.2951 77.1512 69.9395 62.4351 50.1318 37.855 29.6038

Section At Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
Area of prestressing steel Ap mm2 7699.38 7699.38 7699.38 7699.38 7699.38 7699.38 7699.38 7699.38 7699.38
Cg. of prestressing force (from deck top) m 1.46085 1.47727 1.49162 1.61405 1.7189 1.73504 1.93061 2.03054 2.04431

Forces to Pres-stress at day = 36500


Axial force Tonne 790.003 790.323 790.553 780.599 758.577 759.148 770.548 781.621 787.944
Verical Component Tonne 57.9114 57.9354 57.9528 50.7239 42.174 41.0991 24.9221 8.70733 0
Moment Tm 259.523 272.601 284.027 370.076 433.336 445.915 603.312 690.083 706.522

EPC Contractor-M/s Krishna Constructions 260


Design ch-109+720
Design of PSC Girder

Precast Section Property


Section At Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
Area m2 1.92971 1.92971 1.92971 1.43945 0.94469 0.94469 0.94469 0.94469 0.94469
b m 0.825 0.825 0.825 0.55126 0.275 0.275 0.275 0.275 0.275
Iz m4 0.87202 0.87202 0.87202 0.74007 0.60691 0.60691 0.60691 0.60691 0.60691
Ayp m3 0.48196 0.48196 0.48196 0.35357 0.22401 0.22401 0.22401 0.22401 0.22401

Composite Section Property


Section At Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
b m 0.825 0.825 0.825 0.55126 0.275 0.275 0.275 0.275 0.275
Iz m4 1.55604 1.55604 1.55604 1.36551 1.17322 1.17322 1.17322 1.17322 1.17322
Ayc m3 0.8697 0.8697 0.8697 0.7344 0.59786 0.59786 0.59786 0.59786 0.59786

Calculation of Shear Stress


Section At Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
Shear stress at composite centriod due to shear force acting at precast section alone
Net shear force Tonne 25.9089 24.684 20.2536 18.9508 18.7071 14.8928 11.1088 1.31887
Shear stress tv1 Mpa 0.17357 0.16537 0.17553 0.25435 0.25108 0.19988 0.1491 0.0177
Shear stress at composite centriod due to additional shear force on composite section
Addition shear force 80.1889 80.2951 77.1512 69.9395 62.4351 50.1318 37.855 29.6038
Shear stress tv2 Mpa 0.54326 0.54398 0.75271 1.29601 1.15695 0.92896 0.70147 0.54857
Toatal shear stress tv =tv1+tv2 0.71683 0.70934 0.92824 1.55036 1.40803 1.12885 0.85057 0.56627

Axial stress (due to pre stress) fx Mpa 4.09555 4.09675 5.4229 8.02993 8.03597 8.15665 8.27386 8.34079
*stresses due to bending are ignored
Maximum Principal stress
s3 (comp)= [fx/2 + 1/2 Ö(fx2 + 4tv2)] Mpa 4.21739 4.21609 5.57739 8.31886 8.27553 8.30999 8.36039 8.37906
s1 (tens) = [fx/2 - 1/2 Ö(fx2 + 4tv2)] Mpa -0.1218 -0.1193 -0.1545 -0.2889 -0.2396 -0.1533 -0.0865 -0.0383

fctb Mpa 2.3313 2.33136 2.2769 2.16725 2.16898 2.1676 2.16558 2.16484

Check s1 < fctb Provide Min.


Provide
reinf.Min.
Provide
for crack
reinf.Min.
control
for
Provide
crack
reinf.Min.
control
for
Provide
crack
reinf.Min.
control
Provide
for crack
reinf.Min.
control
for
Provide
crack
reinf.Min.
control
for
Provide
crack
reinf.Min.
control
for crack
reinf. control
for crack control

EPC Contractor-M/s Krishna Constructions 261


Design ch-109+720
Design of PSC Girder

Minimum Reinforcement Requirement For Crack Control

r0s, min = K fct,eff / ss 2.60362

K = 0.65 For web with h>800mm 1 0.22

ss = 280 Mpa */Spacing Limited to 150 mm 0.175


0.075 yt
fcteff = fctm
= 3.51563 Mpa 2.52
0.275 2.3
r0s, min = 0.00816 NA

Kc = 0.4 [ 1 - sc / k1 /(h/h*) / fcteff ] */for web


0.175
sc = Mean stress of concrete 0.2
= NED/ bh
0.825
h* = 1 */ for h > 1
h = 2.3 m
NED Minimum Prestressing force in the section

k1 = 1.5 */as NED is compressive force

Kc = 1 */ for wb , considered on the conservative side

*/ Finding Minimum Reinforcement


Section At unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
Web thickness b m 0.825 0.825 0.825 0.825 0.825 0.55126 0.275 0.275 0.275 0.275 0.275
h m 1.675 1.675 1.675 1.675 1.675 1.675 1.675 1.675 1.675
Reinforcement requirement in web
NED Tonne 790.003 790.323 790.553 780.599 758.577 759.148 770.548 781.621 787.94
Area of precast section Ap m2 1.92971 1.92971 1.92971 1.43945 0.94469 0.94469 0.94469 0.94469 0.9447
sc = NED / Ap Mpa 4.0939 4.09555 4.09675 5.4229 8.02993 8.03597 8.15665 8.27386 8.3408
Kc 0.26499 0.26493 0.26489 0.22116 0.13518 0.13498 0.131 0.12714 0.1249

EPC Contractor-M/s Krishna Constructions 262


Design ch-109+720
Design of PSC Girder

Act = b*h/2 m2 0.69094 0.69094 0.69094 0.46168 0.23031 0.23031 0.23031 0.23031 0.2303
As,min web = r0s,min * Kc *Act mm2 1494.25 1493.94 1493.72 833.298 254.092 253.718 246.237 238.971 234.82
Provide on ech face dia of bar mm 12 12 12 12 12 12 12 12 12
Nos Nos. 8 8 8 8 8 8 8 8 8
Spacing provided mm 116.786 116.786 116.786 116.786 116.786 116.786 116.786 116.786 116.79
Reinforcement provided (both face ) mm2 1809.56 1809.56 1809.56 1809.56 1809.56 1809.56 1809.56 1809.56 1809.6
Check OK OK OK OK OK OK OK OK OK
Total web height excluding (top & bottom flange) 1.675 1.675 1.675 1.675 1.675 1.675 1.675 1.675 1.675
Nos of bar required on either face 16 16 16 16 16 16 16 16 16

Section At unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
Reinforcement requirement in bottom flange
b 0.275 0.275 0.275 0.275 0.275 0.275 0.275 0.275 0.275
h considered 0.2875 0.2875 0.2875 0.2875 0.2875 0.2875 0.2875 0.2875 0.2875
Act = b*h m2 79062.5 79062.5 79062.5 79062.5 79062.5 79062.5 79062.5 79062.5 79063
As,min web = r0s,min * Kc *Act mm2 645.251 645.251 645.251 645.251 645.251 645.251 645.251 645.251 645.25

Provide on each face dia of bar mm 12 12 12 12 12 12 12 12 12


Nos Nos. 3 3 3 3 3 3 3 3 3
Spacing mm 117.5 117.5 117.5 117.5 117.5 117.5 117.5 117.5 117.5

Reinforcement provided (both face ) mm2 678.584 678.584 678.584 678.584 678.584 678.584 678.584 678.584 678.58
Check OK OK OK OK OK OK OK OK OK
Total bottom flange width including bottom flange 0.825 0.825 0.825 0.825 0.825 0.825 0.825 0.825 0.825
Nos of bar required at bottom 8 8 8 8 8 8 8 8 8

EPC Contractor-M/s Krishna Constructions 263


Design ch-109+720
Design of PSC Girder

Section At unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
Reinforcement requirement in Top flange
b 0.3625 0.3625 0.3625 0.3625 0.3625 0.3625 0.3625 0.3625 0.3625
h considered 0.2125 0.2125 0.2125 0.2125 0.2125 0.2125 0.2125 0.2125 0.2125
Act = b*h m2 77031.3 77031.3 77031.3 77031.3 77031.3 77031.3 77031.3 77031.3 77031
As,min = r0s,min * Kc *Act mm2 628.674 628.674 628.674 628.674 628.674 628.674 628.674 628.674 628.67

Provide on each face dia of bar mm 12 12 12 12 12 12 12 12 12


Nos Nos. 3 3 3 3 3 3 3 3 3
Spacing mm 141.25 141.25 141.25 141.25 141.25 141.25 141.25 141.25 141.25
Reinforcement provided (both face ) mm2 678.584 678.584 678.584 678.584 678.584 678.584 678.584 678.584 678.58
Check OK OK OK OK OK OK OK OK OK
Total Top flange width including bottom flange 1 1 1 1 1 1 1 1 1
Nos of bar required at top face 8 8 8 8 8 8 8 8 8

EPC Contractor-M/s Krishna Constructions 264


Design ch-109+720
Design of PSC Girder

DESIGN FOR INTERFACE SHEAR : ( IRC 112 / clause 10.3.4)

Grade of concrete fck = 40 Mpa


fcd = 0.44667 *fck
= 17.8667 Mpa

fyd = fyk /gs


fyd = 434.78261 Mpa

vEdi = b VEd /z bi

Ved = Shear Force at composite section

b = Ratio of longitudinal force in new concrete and total longitudinal force


= 1

bi = 1m bi = 1

vRdi = Min msn + r fyd [ m sina +cos a]


0.5nfcd = 4.66839 Mpa 2.52

r = As /Ai
As = Area of reinforcement crossing the inter face
Ai = Interface area of joint

Ai = 1000000 mm2 Considering 1 m length

m = 0.6 Assuming smooth surface


sn = 0 Mpa

a = 90 deg

n = 0.6 [ 1 - fck /310 ]


= 0.5225806

As min = 0.15 % of interface area


= 0.15*bi*1000/100 mm2/m
= 1500 mm2/m

Section At unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7

VED T 0 121.068 121.159 116.308 105.416 94.2351 75.9028 56.9708 44.41325


z m 1.60406 1.61841 1.74084 1.84569 1.86183 2.0574 2.15733 2.171105
vEdi N/mm2 0.75476 0.74863 0.66811 0.57115 0.50614 0.36893 0.26408 0.204565
Legs nos 4 4 4 2 2 2 2 2
dia mm 12 12 12 12 12 12 12 12
Provide Asw spacing mm 100 100 100 100 100 100 100 100
Asw/s provide 4523.89 4523.89 4523.89 2261.95 2261.95 2261.95 2261.95 2261.947
Check As ≥ As,min OK OK OK OK OK OK OK OK
r 0.00452 0.00452 0.00452 0.00226 0.00226 0.00226 0.00226 0.002262
vRdi N/mm2 1.18015 1.18015 1.18015 0.59007 0.59007 0.59007 0.59007 0.590073
Check vEDi ≤ vRdi OK OK OK OK OK OK OK OK

EPC Contractor-M/s Krishna Constructions 265


Design ch-109+720
Design of PSC Girder

CHECK FOR SHEAR IN FLANGED PORTION: ( IRC 112 / clause 10.3.5)

Grade of concrete fck = 40 Mpa


fcd = 0.44667 *fck
= 17.8667 Mpa

fyd = fyk /gs


fyd = 434.783 Mpa

b = Ratio of longitudinal force in deck and total longitudinal force


= 1

vEd = bVED/z hf Total Longitudinal Shear Stress


beff = 2.75 m
Longitudinal force on the one side of flange (section A-A) A
1 hf = 0.22
vEdf = vEd * beff1/ beff

hf = 0.22 m beff1 = 0.875


A
beff1/beff= 0.31818

Variation of qf 45 o ≥ q ≥ 26.5 o For compression flange

CHECK FOR SECTION MAXIMUM PERMISSBLE LONGITUDINAL SHEAR STRESS:


vEdf,max = n fcd sinqf cosqf

Considering qfd = 26.5 o for minimum shear capacity of section

n = 0.6 [ 1 - fck /310 ] , fck in MPA


= 0.52258

vEdf,max = 3.72834 Mpa

EPC Contractor-M/s Krishna Constructions 266


Design ch-109+720
Design of PSC Girder

Section At unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
VED T 121.068 121.159 116.308 105.416 94.2351 75.9028 56.9708 44.4132
z m 1.60406 1.61841 1.74084 1.84569 1.86183 2.0574 2.15733 2.1711
vEd Mpa 3.43073 3.40287 3.03687 2.59612 2.30065 1.67693 1.20037 0.92984
vEdf Mpa 1.0916 1.08273 0.96628 0.82604 0.73202 0.53357 0.38193 0.29586
FINDING qf
qf = 0.5 sin-1 [ 2vEDf / n fcd ]
qf deg 6.76126 6.70532 5.9728 5.09588 4.51074 3.28146 2.34639 1.81678
Check OK/ REVISE qf < qfmax OK OK OK OK OK OK OK OK
Check OK/ REVISE vEDf < vEdf,max OK OK OK OK OK OK OK OK

REINFORCEMENT REQUIREMENT IN DECK FOR LONGITUDINAL SHEAR


Transverse reinforcement per unit length
Asf /sf = vEDf * hf / fyd cot qf

Section At unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
vEdf Mpa 1.0916 1.08273 0.96628 0.82604 0.73202 0.53357 0.38193 0.29586
qdesign deg 26.5 26.5 26.5 26.5 26.5 26.5 26.5 26.5
Asf /sf mm2/m 275.391 273.154 243.775 208.395 184.677 134.61 96.3553 74.6399

EPC Contractor-M/s Krishna Constructions 267


Design ch-109+720
Design of PSC Girder

0.4fcd = 7.14667 Mpa


No exta reinforcement is required if vEdf < 0.4fcd

As there will be transverse bending will exist along with shear b/w precast beam & deck
Check for Minimum Requirement in transverse direction
Reinforcement requirement for transverse bending of deck
As, deck = 1500 mm2/m ( Including Top & Bottom Both reinf)

As,trans = Max Asf if vEdf > 0.4fcd


0.5 Asf + As,deck

As,deck if vEdf < 0.4fcd

Check for Minimum Requirement in Transverse Direction


Section At unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
Asf, exta mm2/m 0 0 0 0 0 0 0 0 0
As, deck mm2/m 1500 1500 1500 1500 1500 1500 1500 1500 1500
As,trans mm2/m 1500 1500 1500 1500 1500 1500 1500 1500 1500
dia mm 12 12 12 12 12 12 12 12 12
At Top spacing mm 100 100 100 100 100 100 100 100 100

dia mm 12 12 12 12 12 12 12 12 12
At Bottom spacing mm 100 100 100 100 100 100 100 100 100

As,trans 2261.95 2261.95 2261.95 2261.95 2261.95 2261.95 2261.95 2261.95 2261.95

Check OK/ REVISE OK OK OK OK OK OK OK OK OK

EPC Contractor-M/s Krishna Constructions 268


Design ch-109+720
Design of PSC Girder

Finding out Ultimate Bending Moment Capacity:


Design Parameters
Concrete Characteristic Strength fck = 50 Mpa
fcd = 0.44667 *fck = 22.3333 Mpa
Using Rectangular stress block
Effective height factor l = 0.8
Compression zone factor h = 1
hfcd = 22.3333 Mpa
Limiting value of xu,max/d = 0.46358
Modulus of Elasticity of cable Ep = 195000 Mpa

Ultimate stress of cables = 1861 Mpa


Total area of cables = 7699.38 mm2
Stress @ 0.1% proof force = 0.87 x 1861
= 1619.07 Mpa
fpd = 1619.07 / 1.15
= 1407.89 Mpa
epd = 1407.89 / 195000
= 0.00722

BENDING MOMENT OUTER GIRDER


Section At unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7 LC-1
Precast Beam Tm -0 -0.0543 -0.7297 8.68949 16.7785 84.6457 142.077 150.301 253.216 314.966 335.549 1.35
Deck Outer Girder Tm -0.0398 0.1364 -0.1294 7.34724 12.2524 56.1694 97.4934 102.3 184.622 235.668 252.239 1.35
Brg. Transfer
SIDL Tm 0 0 0 0 0 0 0 0 0 0 0 1.35
Surfacing Tm 0 0 0 1.672 3.079 15.56 27.248 28.893 49.39 61.68 65.678 1.75
Wind Load Tm 0 0 0 1.646 3.032 15.321 26.828 28.448 48.63 60.731 64.668 0.9
Live Load Tm 0 0 0 10.965 21.4709 114.621 202.816 224.673 358.408 423.907 463.546 1.5

Factored Bending Moment


LC-1 Basic Comb Tm 79.5151 403.051 699.473 754.187 1258.89 1541.81 1661.97

EPC Contractor-M/s Krishna Constructions 269


Design ch-109+720
Design of PSC Girder

2.60362 2.60362 hfcd = 22.3333

1 0.22 1 0.22 x1

0.175 0.175 Cu
0.075 0.0181 xu lxu

0.18125 2.52 0.04375 2.52 z


0.275 1.675 2.3 2.1069 2.3
NA NA
0.1375

0.175 Tu
0.2

0.825 0.825

Section At Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
Area of prestressing steel Ap mm2 7699.38 7699.38 7699.38 7699.38 7699.38 7699.38 7699.38 7699.38 7699.38
Cg. of prestressing force (from girder top) m 1.46085 1.47727 1.49162 1.61405 1.7189 1.73504 1.93061 2.03054 2.04431
Cg. of prestressing force (from deck top) m 1.68085 1.69727 1.71162 1.83405 1.9389 1.95504 2.15061 2.25054 2.26431
Total prestressing force T 790.003 790.323 790.553 780.599 758.577 759.148 770.548 781.621 787.944
Prestrain at cg. Of cables 0.00526 0.00526 0.00527 0.0052 0.00505 0.00506 0.00513 0.00521 0.00525

EPC Contractor-M/s Krishna Constructions 270


Design ch-109+720
Design of PSC Girder

Capacity Calculation by crushing of concrete :


Section At Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
Strain at deck top 0.0035 0.0035 0.0035 0.0035 0.0035 0.0035 0.0035 0.0035 0.0035
Assuming NA At xu m 0.23302 0.23302 0.23302 0.23302 0.23302 0.23302 0.23302 0.23302 0.23302
lxu m 0.18642 0.18642 0.18642 0.18642 0.18642 0.18642 0.18642 0.18642 0.18642

Strain at cg. of prestressing steel 0.02175 0.02199 0.02221 0.02405 0.02562 0.02586 0.0288 0.0303 0.03051
Total strain at cg. of prestressing cables = prestrain + bending strain 0.02701 0.02726 0.02747 0.02925 0.03067 0.03092 0.03393 0.03551 0.03576

Check eps > epd OK OK OK OK OK OK OK OK OK

Total tensile force fpd*Ap T 1083.99 1083.99 1083.99 1083.99 1083.99 1083.99 1083.99 1083.99 1083.99
Calculating Compression force
Area of compression force upto hfcd m2 0.48537 0.48537 0.48537 0.48537 0.48537 0.48537 0.48537 0.48537 0.48537
Total compression force = hfcd * Ac Tonne 1083.99 1083.99 1083.99 1083.99 1083.99 1083.99 1083.99 1083.99 1083.99
Total compression C - Total Tension T 0 0 0 0 0 0 0 0 0
Check OK OK OK OK OK OK OK OK OK

Cg. of compression force below deck top m 0.09321 0.09321 0.09321 0.09321 0.09321 0.09321 0.09321 0.09321 0.09321

Lever arm b/w Tension & compression force m 1.58764 1.60406 1.61841 1.74084 1.84569 1.86183 2.0574 2.15733 2.1711

Moment capacity Tm 1720.98 1738.77 1754.33 1887.05 2000.7 2018.19 2230.2 2338.51 2353.45
Factored moment at section Tm 0 0 79.5151 403.051 699.473 754.187 1258.89 1541.81 1661.97

Check OK OK OK OK OK OK OK OK OK

EPC Contractor-M/s Krishna Constructions 271


Design ch-109+720
Design of PSC Girder

STRESS CALCULATION DUE TO TEMPERATURE OUTER GIRDER:


Coefficient of thermal expansion = 1.2E-05
Ec = 35000 N/mm2
Es = 200000 N/mm2

OUTER GIRDER, MID SPAN


POSITIVE TEMPERATURE DIFFERENCES NEGATIVE TEMPERATURE DIFFERENCES
2.60362
17.8 f1 f1 -10.6
0.15 1
f2
4 0.22 0.25
f3 f2
0.25 f3 -0.7
f4 0.175 f4 0.2
f5 0.075 f5
f6 f6
2.52
2.52
1.97 2.52 0.275 1.675 1.62

f7 f7
0.175
f9 f8
f8 0.2
f9 -0.8
0.15 f10 0.2 f10 0.25
2.1 0.825 -6.6

POSITIVE TEMPERATURE DIFFERENCES


Points Depth temp b1 b2 Av. widthArea y A*y A*y2 av. temp A*t A*t*y +ve Temperature
mm oC m m2 m m3 m4 oC m2 oC m3 oC h Temp
0 0 17.8
f1 0 17.8 0.15 4
f2 0.15 4 2.60362 2.60362 2.60362 0.390544 0.075 0.02929 0.0022 10.9 4.25693 0.31927 0.4 0
f3 0.22 2.88 2.60362 2.60362 2.60362 0.182254 0.185 0.03372 0.00624 3.44 0.62695 0.11599 2.37 0
f4 0.395 0.08 2.60362 1 1.80181 0.315317 0.32 0.10105 0.03239 1.48 0.46667 0.14956 2.52 2.1
f5 0.4 0 1 0.95167 0.97583 0.004879 0.398 0.00194 0.00077 0.04 0.0002 7.8E-05
f6 0.47 0 0.95167 0.275 0.61333 0.042933 0.441 0.01895 0.00837 0 0 0
f7 2.145 0 0.275 0.275 0.275 0.460625 1.308 0.60227 0.78746 0 0 0
f8 2.32 0 0.275 0.825 0.55 0.09625 2.218 0.21347 0.47347 0 0 0
f9 2.37 0 0.825 0.825 0.825 0.04125 2.345 0.09673 0.22683 0 0 0
f10 2.5199 2.0986 0.825 0.825 0.825 0.123668 2.445 0.30236 0.73926 1.0493 0.12976 0.31727

EPC Contractor-M/s Krishna Constructions 272


Design ch-109+720
Design of PSC Girder

2.5199
Total 1.657719 1.39979 2.27698 5.48051 0.90216

e0 x SA - q x SAy = a x SAt
e0 x 1.65772 - q x 1.39979 = 1E-05x 5.48051 ------------------- (1)

e0 SAy - q x SAy2 = a x SAyt


e0 x 1.39979 - q x 2.27698 = 1E-05x 0.90216 ------------------- (2) + ve = compression
- ve = tension
By solving equation (1) & (2)
e0 = 7.4E-05
q = 4.1E-05 rad./m

STRESSES AT
Dtop DbottomGtop Gbottom 4.88
Points Depth f ei = Ec ( at + yq - eo ) ytop 0 0.22 0.22 2.52
mm N/mm2 Eigen stresses N/mm2 N/mm2 N/mm2 N/mm2 -2.02
0 0
f1 0 4.8808
f2 0.15 -0.7008 4.8808 -1.071 -1.0712 1.88716
f3 0.22 -1.0712
f4 0.395 -1.9971
f5 0.4 -2.0236
f6 0.47 -1.9236 Stresses at CG Of steel & outermost steel is in steel
f7 2.145 0.47002
f8 2.32 0.72009
f9 2.37 0.79154
f10 2.52 1.88716 1.89
Positive temp. stress
2.52 0

EPC Contractor-M/s Krishna Constructions 273


Design ch-109+720
Design of PSC Girder

NEGATIVE TEMPERATURE DIFFERENCES


Points Depth temp b1 b2 Av. widthArea y A*y A*y2 av. temp A*t A*t*y -ve Temperature
mm oC m m2 m m3 m4 oC m2 oC m3 oC h Temp
0 0 -10.6
f1 0 -10.6 0.25 -0.7
f2 0.22 -1.888 2.60362 2.60362 2.60362 0.572797 0.11 0.06301 0.00693 -6.244 -3.5765 -0.3934 0.45 0
f3 0.25 -0.7 2.60362 1 1.80181 0.054054 0.237 0.01282 0.00304 -1.294 -0.0699 -0.0166 2.07 0
f4 0.395 -0.1925 1 1 1 0.145 0.323 0.04676 0.01508 -0.4463 -0.0647 -0.0209 2.27 -0.8
f5 0.45 -1E-16 1 0.46833 0.73417 0.040379 0.426 0.01719 0.00732 -0.0963 -0.0039 -0.0017 2.52 -6.6
f6 0.47 0 0.46833 0.275 0.37167 0.007433 0.461 0.00343 0.00158 -6E-17 -4E-19 -2E-19
f7 2.145 -0.3 0.275 0.275 0.275 0.460625 1.308 0.60227 0.78746 -0.15 -0.0691 -0.0903
f8 2.27 -0.8 0.275 0.66786 0.47143 0.058929 2.199 0.12957 0.28491 -0.55 -0.0324 -0.0713
f9 2.32 -1.96 0.66786 0.825 0.74643 0.037321 2.294 0.08562 0.19642 -1.38 -0.0515 -0.1182
f10 2.5199 -6.5977 0.825 0.825 0.825 0.164918 2.42 0.39909 0.96578 -4.2788 -0.7057 -1.7077
2.5199
Total 1.541457 1.35977 2.26853 -4.5737 -2.4199

e0 x SA - q x SAy = a x SAt
e0 x 1.54146 - q x 1.35977 = 1E-05x -4.5737 ------------------- (1)

e0 SAy - q x SAy2 = a x SAyt


e0 x 1.35977 - q x 2.26853 = 1E-05x -2.4199 ------------------- (2)

By solving equation (1) & (2)


e0 = -5E-05
q = -2E-05 rad./m

EPC Contractor-M/s Krishna Constructions 274


Design ch-109+720
Design of PSC Girder

STRESSES AT
Dtop DbottomGtop Gbottom -2.65
Points Depth f ei = Ec ( at + yq - eo ) ytop 0 0.22 0.22 2.52
mm N/mm2 Eigen stresses N/mm2 N/mm2 N/mm2 N/mm2 1.52
0 0
f1 0 -2.6462
f2 0.22 0.87329 -2.64619 0.873 0.87329 -2.5638
f3 0.25 1.35321
f4 0.395 1.47438
f5 0.45 1.52034
f6 0.47 1.50765 Stresses At cg. Of steel & outermost steel is in steel
f7 2.145 0.31908
f8 2.27 0.02978
f9 2.32 -0.4891
f10 2.52 -2.5638 -2.56
Positive temp. stress
2.52 0

OUTER GIRDER, SUPPORT SECTION


POSITIVE TEMPERATURE DIFFERENCES NEGATIVE TEMPERATURE DIFFERENCES
2.60362
17.8 f1 f1 -10.6
0.15 1
f2
4 0.22 0.25
f3 f2
0.25 f3 -0.7
f4 0.175 f4 0.2
f5 0.0181
f6 f5
2.5199 f6
2.5199
1.9699 2.5199 2.1068 1.6199

f7

f8
0.2
f7 -0.8
0.15 f8 f9 0.25
2.1 0.825 -6.6

EPC Contractor-M/s Krishna Constructions 275


Design ch-109+720
Design of PSC Girder

POSITIVE TEMPERATURE DIFFERENCES


Points Depth temp b1 b2 Av. widthArea y A*y A*y2 av. temp A*t A*t*y +ve Temperature
mm oC m m2 m m3 m4 oC m2 oC m3 oC h Temp
0 0 17.8
f1 0 17.8 0.15 4
f2 0.15 4 2.60362 2.60362 2.60362 0.390544 0.075 0.02929 0.0022 10.9 4.25693 0.31927 0.4 0
f3 0.22 2.88 2.60362 2.60362 2.60362 0.182254 0.185 0.03372 0.00624 3.44 0.62695 0.11599 2.3699 0
f4 0.395 0.08 1 1 1 0.175 0.308 0.05381 0.01655 1.48 0.259 0.07964 2.5199 2.1
f5 0.4 0 1 0.95167 0.97583 0.004879 0.398 0.00194 0.00077 0.04 0.0002 7.8E-05
f6 0.4131 0 0.95167 0.825 0.88833 0.01164 0.407 0.00473 0.00193 0 0 0
f7 2.3699 0 0.825 0.825 0.825 1.614357 1.392 2.24638 3.12584 0 0 0
f8 2.5199 2.1 0.825 0.825 0.825 0.12375 2.445 0.30256 0.73972 1.05 0.12994 0.31768
2.5199
Total 2.502424 2.67243 3.89324 5.27301 0.83266

e0 x SA - q x SAy = a x SAt
e0 x 2.50242 - q x 2.67243 = 1E-05x 5.27301 ------------------- (1)

e0 SAy - q x SAy2 = a x SAyt


e0 x 2.67243 - q x 3.89324 = 1E-05x 0.83266 ------------------- (2) + ve = compression
- ve = tension
By solving equation (1) & (2)
e0 = 8.4E-05
q = 5.5E-05 rad./m
4.52
STRESSES AT
Dtop DbottomGtop Gbottom -2.18
Points Depth f ei = Ec ( at + yq - eo ) ytop 0 0.22 0.22 2.52
mm N/mm2 Eigen stresses N/mm2 N/mm2 N/mm2 N/mm2
0 0
f1 0 4.51996
f2 0.15 -0.9851 4.519961 -1.32 -1.3198 2.80577
f3 0.22 -1.3198
f4 0.395 -2.1564
f5 0.4 -2.1803
f6 0.4131 -2.1549 Stresses At cg. Of steel & outermost steel is in steel
f7 2.3699 1.63987
Positive temp. stress
f8 2.5209 2.81276
2.5209 0

EPC Contractor-M/s Krishna Constructions 276


Design ch-109+720
Design of PSC Girder

NEGATIVE TEMPERATURE DIFFERENCES


Points Depth temp b1 b2 Av. widthArea y A*y A*y2 av. temp A*t A*t*y -ve Temperature
mm oC m m2 m m3 m4 oC m2 oC m3 oC h Temp
0 0 -10.6
f1 0 -10.6 0.25 -0.7
f2 0.22 -1.888 2.60362 2.60362 2.60362 0.572797 0.11 0.06301 0.00693 -6.244 -3.5765 -0.3934 0.45 0
f3 0.25 -0.7 1 1 1 0.03 0.235 0.00705 0.00166 -1.294 -0.0388 -0.0091 2.0699 0
f4 0.395 -0.1925 1 1 1 0.145 0.323 0.04676 0.01508 -0.4463 -0.0647 -0.0209 2.2699 -0.8
f5 0.4131 -0.1291 1 0.825 0.9125 0.016519 0.404 0.00668 0.0027 -0.1608 -0.0027 -0.0011 2.5199 -6.6
f6 0.45 -1E-16 0.825 0.825 0.825 0.03044 0.432 0.01314 0.00567 -0.0646 -0.002 -0.0008
f7 2.0699 0 0.825 0.825 0.825 1.336418 1.26 1.68382 2.12153 -6E-17 -7E-17 -9E-17
f8 2.2699 -0.8 0.825 0.825 0.825 0.165 2.17 0.35803 0.7769 -0.4 -0.066 -0.1432
f9 2.5199 -6.6 0.825 0.825 0.825 0.20625 2.395 0.49395 1.18296 -3.7 -0.7631 -1.8276
2.5199
Total 2.502424 2.67244 4.11342 -4.5138 -2.3962

e0 x SA - q x SAy = a x SAt
e0 x 2.50242 - q x 2.67244 = 1E-05x -4.5138 ------------------- (1)

e0 SAy - q x SAy2 = a x SAyt


e0 x 2.67244 - q x 4.11342 = 1E-05x -2.3962 ------------------- (2)

By solving equation (1) & (2)


e0 = -5E-05
q = -2E-05 rad./m

EPC Contractor-M/s Krishna Constructions 277


Design ch-109+720
Design of PSC Girder

STRESSES AT
Dtop DbottomGtop Gbottom
-2.83
Points Depth f ei = Ec ( at + yq - eo ) ytop 0 0.22 0.22 2.52
mm N/mm2 Eigen stresses N/mm2 N/mm2 N/mm2 N/mm2 1.23
0 0
f1 0 -2.831
f2 0.22 0.65017 -2.831 0.65 0.65017 -3.1788
f3 0.25 1.12488
f4 0.395 1.2208
f5 0.4131 1.23277
f6 0.45 1.25718 Stresses At cg. Of steel & outermost steel is in steel
f7 2.0699 -0.0525
f8 2.2699 -0.5502
f9 2.5209 -3.1883
0.00
2.5209 0 Positive temp. stress

Summery of stresses at sections (+ve Temperature Differences)


Section At unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7

Dtop 0 N/mm2 4.51996 4.51996 4.51996 4.69956 4.8808 4.8807996 4.8808 4.8808 4.8808
Dbottom 0.22 N/mm2 -1.3198 -1.3198 -1.3198 -1.1961 -1.0712 -1.071219 -1.0712 -1.0712 -1.0712
Gtop 0.22 N/mm2 -1.3198 -1.3198 -1.3198 -1.1961 -1.0712 -1.071219 -1.0712 -1.0712 -1.0712
STRESSES Gbottom
AT 2.52 N/mm2 2.80577 2.80577 2.80577 2.34856 1.88716 1.8871614 1.88716 1.88716 1.88716

Summery of stresses at sections (-ve Temperature Differences)


Section At unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7

Dtop 0 N/mm2 -2.831 -2.831 -2.831 -2.739 -2.6462 -2.646192 -2.6462 -2.6462 -2.6462
Dbottom 0.22 N/mm2 0.65017 0.65017 0.65017 0.76122 0.87329 0.8732855 0.87329 0.87329 0.87329
Gtop 0.22 N/mm2 0.65017 0.65017 0.65017 0.76122 0.87329 0.8732855 0.87329 0.87329 0.87329
STRESSES Ast_cg
AT 2.52 N/mm2 -3.1788 -3.1788 -3.1788 -2.8727 -2.5638 -2.563776 -2.5638 -2.5638 -2.5638

EPC Contractor-M/s Krishna Constructions 278


Design ch-109+720
Design of PSC Girder

CALCULATING STRESSES DUE TO DIFFERENTIAL SHRINKAGE :


In PSC Girder From deck slab casting to transfer to Permamnent brg.
From day = 35 to day 63
ecs ,D (28 - 0) = 5.5E-05
ecs,P (63 - 35) = 3.4E-05

Differential shrinkage strain


ediff = ecs ,D ( t2 - t1 ) - [ ecs,P (t2 -t1) ]
= 5.5E-05 - 3.4E-05
= 2E-05

Restarined Force in slab 2.75


Fs = ediff Ecf Aslab (1-e-f ) / f
0.22
f = 0.5907 dcen
2.52
(1- e-f ) / f = 0.75514 2.3

Ecf = Modulus of elasticity of flange concrete


= 33000 Gpa

Finding Restrained stress in deck slab


Section At unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
Acef m2 0.605 0.605 0.605 0.605 0.605 0.605 0.605 0.605 0.605 0.605 0.605
Fs T 30.6235 30.6235 30.6235 30.6235 30.6235 30.6235 30.6235 30.6235 30.6235 30.6235 30.6235
Restrained stress Fs/Acef N/mm2 -0.5062 -0.5062 -0.5062 -0.5062 -0.5062 -0.5062 -0.5062 -0.5062 -0.5062 -0.5062 -0.5062

EPC Contractor-M/s Krishna Constructions 279


Design ch-109+720
Design of PSC Girder

Equilibrium Forces in composite section


Section At unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7

A m2 2.50251 2.50251 2.50251 2.50251 2.50251 2.01225 1.51748 1.51748 1.51748 1.51748 1.51748
Izz m4 1.55604 1.55604 1.55604 1.55604 1.55604 1.36551 1.17322 1.17322 1.17322 1.17322 1.17322
Composite section yt m 1.06798 1.06798 1.06798 1.06798 1.06798 0.98086 0.89293 0.89293 0.89293 0.89293 0.89293

dcen m 0.95798 0.95798 0.95798 0.95798 0.95798 0.87086 0.78293 0.78293 0.78293 0.78293 0.78293
Fs/Ac N/mm2 0.12237 0.12237 0.12237 0.12237 0.12237 0.15219 0.2018 0.2018 0.2018 0.2018 0.2018
Mcs Fs*dcen Tm 29.3368 29.3368 29.3368 29.3368 29.3368 26.6687 23.9761 23.9761 23.9761 23.9761 23.9761

Top N/mm2 0.20135 0.20135 0.20135 0.20135 0.20135 0.19156 0.18248 0.18248 0.18248 0.18248 0.18248
deck Bottom N/mm2 0.15987 0.15987 0.15987 0.15987 0.15987 0.1486 0.13752 0.13752 0.13752 0.13752 0.13752
Top N/mm2 0.15987 0.15987 0.15987 0.15987 0.15987 0.1486 0.13752 0.13752 0.13752 0.13752 0.13752
Stress at fibers
Girderdue Bottom N/mm2
to Moment Component -0.2738 -0.2738 -0.2738 -0.2738 -0.2738 -0.3006 -0.3325 -0.3325 -0.3325 -0.3325 -0.3325

EPC Contractor-M/s Krishna Constructions 280


Design ch-109+720
Design of PSC Girder

Net Stresses at deck/ bottom fibers


Section At unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7

0 0 0 0 0 0 0 0 0 0 0 0
Top N/mm2 0 -0.1824 -0.1824 -0.1824 -0.1824 -0.1824 -0.1624 -0.1219 -0.1219 -0.1219 -0.1219 -0.1219
deck Bottom N/mm2 0.22 -0.2239 -0.2239 -0.2239 -0.2239 -0.2239 -0.2054 -0.1668 -0.1668 -0.1668 -0.1668 -0.1668
Top N/mm2 0.22 0.28225 0.28225 0.28225 0.28225 0.28225 0.30078 0.33932 0.33932 0.33932 0.33932 0.33932
Stress at fibers
Girderdue Bottom N/mm2
to Moment Component2.52 -0.1514 -0.1514 -0.1514 -0.1514 -0.1514 -0.1484 -0.1307 -0.1307 -0.1307 -0.1307 -0.1307
2.52 0 0 0 0 0 0 0 0 0 0 0

- -
-0.5 0 0.5 -0.5 0 0.5
0.18 0.12
2449 0.28 1889 0.33
-0.63
83 2245 -0.63
357 9324
931 781

-0.15 -0.13
1384 0704
82 75
Support Section Mid Span

Stresses Due to differential Shrinkage

EPC Contractor-M/s Krishna Constructions 281


Design ch-109+720
Design of PSC Girder

CALCULATING STRESSES DUE TO DIFFERENTIAL SHRINKAGE :


In PSC Girder From deck slab casting to SIDL.
From day = 35 to day 64
ecs ,D (29 - 0) = 5.6E-05
ecs,P (64 - 35) = 3.5E-05

Differential shrinkage strain


ediff = ecs ,D ( t2 - t1 ) - [ ecs,P (t2 -t1) ]
= 5.6E-05 - 3.5E-05
= 2E-05

Restarined Force in slab 2.75


Fs = ediff Ecf Aslab (1-e-f ) / f
0.22
f = 0.59672 dcen
2.52
(1- e-f ) / f = 0.75309 2.3

Ecf = Modulus of elasticity of flange concrete


= 33000 Gpa

Finding Restrained stress in deck slab


Section At unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
Acef m2 0.605 0.605 0.605 0.605 0.605 0.605 0.605 0.605 0.605 0.605 0.605
Fs T 30.6105 30.6105 30.6105 30.6105 30.6105 30.6105 30.6105 30.6105 30.6105 30.6105 30.6105
Restrained stress Fs/Acef N/mm2 -0.506 -0.506 -0.506 -0.506 -0.506 -0.506 -0.506 -0.506 -0.506 -0.506 -0.506

Equilibrium Forces in composite section


Section At unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7

A m2 2.50251 2.50251 2.50251 2.50251 2.50251 2.01225 1.51748 1.51748 1.51748 1.51748 1.51748
Izz m4 1.55604 1.55604 1.55604 1.55604 1.55604 1.36551 1.17322 1.17322 1.17322 1.17322 1.17322
Composite section yt m 1.06798 1.06798 1.06798 1.06798 1.06798 0.98086 0.89293 0.89293 0.89293 0.89293 0.89293

dcen m 0.95798 0.95798 0.95798 0.95798 0.95798 0.87086 0.78293 0.78293 0.78293 0.78293 0.78293

EPC Contractor-M/s Krishna Constructions 282


Design ch-109+720
Design of PSC Girder

Fs/Ac N/mm2 0.12232 0.12232 0.12232 0.12232 0.12232 0.15212 0.20172 0.20172 0.20172 0.20172 0.20172
Mcs Fs*dcen Tm 29.3244 29.3244 29.3244 29.3244 29.3244 26.6574 23.9659 23.9659 23.9659 23.9659 23.9659

Top N/mm2 0.20127 0.20127 0.20127 0.20127 0.20127 0.19148 0.1824 0.1824 0.1824 0.1824 0.1824
deck Bottom N/mm2 0.15981 0.15981 0.15981 0.15981 0.15981 0.14853 0.13746 0.13746 0.13746 0.13746 0.13746
Top N/mm2 0.15981 0.15981 0.15981 0.15981 0.15981 0.14853 0.13746 0.13746 0.13746 0.13746 0.13746
Stress at fibers
Girderdue Bottom N/mm2
to Moment Component -0.2736 -0.2736 -0.2736 -0.2736 -0.2736 -0.3005 -0.3324 -0.3324 -0.3324 -0.3324 -0.3324

Net Stresses at deck/ bottom fibers


Section At unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7

0 0 0 0 0 0 0 0 0 0 0 0
Top N/mm2 0 -0.1824 -0.1824 -0.1824 -0.1824 -0.1824 -0.1624 -0.1218 -0.1218 -0.1218 -0.1218 -0.1218
deck Bottom N/mm2 0.22 -0.2238 -0.2238 -0.2238 -0.2238 -0.2238 -0.2053 -0.1668 -0.1668 -0.1668 -0.1668 -0.1668
Top N/mm2 0.22 0.28213 0.28213 0.28213 0.28213 0.28213 0.30066 0.33918 0.33918 0.33918 0.33918 0.33918
Stress at fibers
Girderdue Bottom N/mm2
to Moment Component2.52 -0.1513 -0.1513 -0.1513 -0.1513 -0.1513 -0.1484 -0.1306 -0.1306 -0.1306 -0.1306 -0.1306
2.52 0 0 0 0 0 0 0 0 0 0 0

- -
-0.5 0 0.5 -0.5 0 0.5
0.18 0.12
2372 0.28 1837 0.33
-0.63
609 2126 -0.63
768 9181
473 165

-
-0.15
0.13
1320
0649
748
Support Section 431 Mid Span

Stresses Due to differential Shrinkage

EPC Contractor-M/s Krishna Constructions 283


Design ch-109+720
Design of PSC Girder

CALCULATING STRESSES DUE TO DIFFERENTIAL SHRINKAGE :


In PSC Girder From deck slab casting to LL.
From day = 35 to day 92
ecs ,D (57 - 0) = 8.1E-05
ecs,P (92 - 35) = 6.1E-05

Differential shrinkage strain


ediff = ecs ,D ( t2 - t1 ) - [ ecs,P (t2 -t1) ]
= 8.1E-05 - 6.1E-05
= 2E-05

Restarined Force in slab 2.75


Fs = ediff Ecf Aslab (1-e-f ) / f
0.22
f = 0.72287 dcen
2.52
(1- e-f ) / f = 0.71194 2.3

Ecf = Modulus of elasticity of flange concrete


= 33000 Gpa

Finding Restrained stress in deck slab


Section At unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
Acef m2 0.605 0.605 0.605 0.605 0.605 0.605 0.605 0.605 0.605 0.605 0.605
Fs T 29.09 29.09 29.09 29.09 29.09 29.09 29.09 29.09 29.09 29.09 29.09
Restrained stress Fs/Acef N/mm2 -0.4808 -0.4808 -0.4808 -0.4808 -0.4808 -0.4808 -0.4808 -0.4808 -0.4808 -0.4808 -0.4808

EPC Contractor-M/s Krishna Constructions 284


Design ch-109+720
Design of PSC Girder

Equilibrium Forces in composite section


Section At unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7

A m2 2.50251 2.50251 2.50251 2.50251 2.50251 2.01225 1.51748 1.51748 1.51748 1.51748 1.51748
Izz m4 1.55604 1.55604 1.55604 1.55604 1.55604 1.36551 1.17322 1.17322 1.17322 1.17322 1.17322
Composite section yt m 1.06798 1.06798 1.06798 1.06798 1.06798 0.98086 0.89293 0.89293 0.89293 0.89293 0.89293

dcen m 0.95798 0.95798 0.95798 0.95798 0.95798 0.87086 0.78293 0.78293 0.78293 0.78293 0.78293
Fs/Ac N/mm2 0.11624 0.11624 0.11624 0.11624 0.11624 0.14456 0.1917 0.1917 0.1917 0.1917 0.1917
Mcs Fs*dcen Tm 27.8677 27.8677 27.8677 27.8677 27.8677 25.3332 22.7754 22.7754 22.7754 22.7754 22.7754

Top N/mm2 0.19127 0.19127 0.19127 0.19127 0.19127 0.18197 0.17334 0.17334 0.17334 0.17334 0.17334
deck Bottom N/mm2 0.15187 0.15187 0.15187 0.15187 0.15187 0.14116 0.13063 0.13063 0.13063 0.13063 0.13063
Top N/mm2 0.15187 0.15187 0.15187 0.15187 0.15187 0.14116 0.13063 0.13063 0.13063 0.13063 0.13063
Stress at fibers
Girderdue Bottom N/mm2
to Moment Component -0.26 -0.26 -0.26 -0.26 -0.26 -0.2855 -0.3159 -0.3159 -0.3159 -0.3159 -0.3159

EPC Contractor-M/s Krishna Constructions 285


Design ch-109+720
Design of PSC Girder

Net Stresses at deck/ bottom fibers


Section At unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7

0 0 0 0 0 0 0 0 0 0 0 0
Top N/mm2 0 -0.1733 -0.1733 -0.1733 -0.1733 -0.1733 -0.1543 -0.1158 -0.1158 -0.1158 -0.1158 -0.1158
deck Bottom N/mm2 0.22 -0.2127 -0.2127 -0.2127 -0.2127 -0.2127 -0.1951 -0.1585 -0.1585 -0.1585 -0.1585 -0.1585
Top N/mm2 0.22 0.26811 0.26811 0.26811 0.26811 0.26811 0.28572 0.32233 0.32233 0.32233 0.32233 0.32233
Stress at fibers
Girderdue Bottom N/mm2
to Moment Component2.52 -0.1438 -0.1438 -0.1438 -0.1438 -0.1438 -0.141 -0.1242 -0.1242 -0.1242 -0.1242 -0.1242
2.52 0 0 0 0 0 0 0 0 0 0 0

- -
-0.5 0 0.5 -0.5 0 0.5
0.17 0.11
3313 0.26 5785 0.32
-0.63
319 8111 -0.63
523 2332
947 469

-0.14 -0.12
3803 4159
947 47
Support Section Mid Span

Stresses Due to differential Shrinkage

EPC Contractor-M/s Krishna Constructions 286


Design ch-109+720
Design of PSC Girder

CALCULATING STRESSES DUE TO DIFFERENTIAL SHRINKAGE :


In PSC Girder From deck slab casting to end.
From day = 35 to day 36500
ecs ,D (36465 - 0) = 0.00036
ecs,P (36500 - 35) = 0.00028

Differential shrinkage strain


ediff = ecs ,D ( t2 - t1 ) - [ ecs,P (t2 -t1) ]
= 0.00036 - 0.00028
= 8.4E-05

Restarined Force in slab 2.75


Fs = ediff Ecf Aslab (1-e-f ) / f
0.22
f = 0.72287 dcen
2.52
(1- e-f ) / f = 0.71194 2.3

Ecf = Modulus of elasticity of flange concrete


= 33000 Gpa

Finding Restrained stress in deck slab


Section At unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7
Acef m2 0.605 0.605 0.605 0.605 0.605 0.605 0.605 0.605 0.605 0.605 0.605
Fs T 119.725 119.725 119.725 119.725 119.725 119.725 119.725 119.725 119.725 119.725 119.725
Restrained stress Fs/Acef N/mm2 -1.9789 -1.9789 -1.9789 -1.9789 -1.9789 -1.9789 -1.9789 -1.9789 -1.9789 -1.9789 -1.9789

EPC Contractor-M/s Krishna Constructions 287


Design ch-109+720
Design of PSC Girder

Equilibrium Forces in composite section


Section At unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7

A m2 2.50251 2.50251 2.50251 2.50251 2.50251 2.01225 1.51748 1.51748 1.51748 1.51748 1.51748
Izz m4 1.55604 1.55604 1.55604 1.55604 1.55604 1.36551 1.17322 1.17322 1.17322 1.17322 1.17322
Composite section yt m 1.06798 1.06798 1.06798 1.06798 1.06798 0.98086 0.89293 0.89293 0.89293 0.89293 0.89293

dcen m 0.95798 0.95798 0.95798 0.95798 0.95798 0.87086 0.78293 0.78293 0.78293 0.78293 0.78293
Fs/Ac N/mm2 0.47842 0.47842 0.47842 0.47842 0.47842 0.59498 0.78897 0.78897 0.78897 0.78897 0.78897
Mcs Fs*dcen Tm 114.694 114.694 114.694 114.694 114.694 104.263 93.7362 93.7362 93.7362 93.7362 93.7362

Top N/mm2 0.7872 0.7872 0.7872 0.7872 0.7872 0.74893 0.71342 0.71342 0.71342 0.71342 0.71342
deck Bottom N/mm2 0.62504 0.62504 0.62504 0.62504 0.62504 0.58095 0.53765 0.53765 0.53765 0.53765 0.53765
Top N/mm2 0.62504 0.62504 0.62504 0.62504 0.62504 0.58095 0.53765 0.53765 0.53765 0.53765 0.53765
Stress at fibers
Girderdue Bottom N/mm2
to Moment Component -1.0703 -1.0703 -1.0703 -1.0703 -1.0703 -1.1752 -1.3 -1.3 -1.3 -1.3 -1.3

EPC Contractor-M/s Krishna Constructions 288


Design ch-109+720
Design of PSC Girder

Net Stresses at deck/ bottom fibers


Section At unit Face Jacking c/L brg. Face TS deff TE L/8 2L/8 3L/8 4L/8
Dist. From c/L brg. m -0.55 -0.4 0 0.213 0.4 2.142 3.9 4.175 8.35 12.525 16.7

0 0 0 0 0 0 0 0 0 0 0 0
Top N/mm2 0 -0.7133 -0.7133 -0.7133 -0.7133 -0.7133 -0.635 -0.4765 -0.4765 -0.4765 -0.4765 -0.4765
Deck Bottom N/mm2 0.22 -0.8755 -0.8755 -0.8755 -0.8755 -0.8755 -0.803 -0.6523 -0.6523 -0.6523 -0.6523 -0.6523
Top N/mm2 0.22 1.10346 1.10346 1.10346 1.10346 1.10346 1.17593 1.32662 1.32662 1.32662 1.32662 1.32662
Stress at fibers
Girderdue Bottom N/mm2
to Moment Component2.52 -0.5919 -0.5919 -0.5919 -0.5919 -0.5919 -0.5802 -0.511 -0.511 -0.511 -0.511 -0.511
2.52 0 0 0 0 0 0 0 0 0 0 0

- -
-2 0 2 -2 0 2
0.71 0.47
3300 1.10 6535 1.32
-0.63
957 3461 -0.63
359 6615
116 056

-0.59 -0.51
1850 0999
03 783
Support Section Mid Span

Stresses Due to differential Shrinkage

EPC Contractor-M/s Krishna Constructions 289


Design ch-109+720
Design of PSC Girder

Design of Anchorage Zone


UTS of cables = 349.029 Tonne
Design forces for anchorage = 1.1 *UTS IRC 112 :2011 clause no. 13.2.3
= 383.932 Tonne

2Yo = Side of end block


2Ypo = Side of loaded area
= 190 x 190

0.175

0.825

5
0 2.3

0.5
4

0.5
3

0.5
1 2
0.3

0.2125 0.4 0.2125

Calculation of stress behind Anchorage as per IRC SP:105

In IRC SP:105 reference made to Euro Code EC2- Annex J for checking of concrete stresses.

Calculation of Bursting Reinforcement :

Prism Dimensions (2Ypo/Yo


Yo) Fbrust/ Pk Fbrust
Cable No. Vertically Laterally Vertically Laterally Vertically Laterally Vertically Laterally
1 550 412.5 0.345455 0.46061 0.24636 0.20576 94.5868 78.9968
2 550 412.5 0.345455 0.46061 0.24636 0.20576 94.5868 78.9968
3 500 825 0.38 0.2303 0.236 0.1996 90.6078 76.6312
4 500 825 0.38 0.2303 0.236 0.1996 90.6078 76.6312
5 500 825 0.38 0.2303 0.236 0.1996 90.6078 76.6312
6 500 825 0.38 0.2303 0.236 0.1996 90.6078 76.6312

EPC Contractor-M/s Krishna Constructions 290


Design ch-109+720
Design of PSC Girder

fck = 50 Mpa
fck (cyl) = 40 Mpa

Permissible compressive stress behind anchorage = 0.6 x fck,cyl = 24 Mpa

C X C' = 550 X 412.5 = 226875 mm2


Pmax = 3766.37 kN
s1 = Pmax/C X C' = 16.6011 Mpa OK

Calculation of Bursting Reinforcement as per IRC SP:105 Example

Grade reinforcing steel fyk = 500 Mpa


Allowable stress = 0.87 *fyk
fyd = 435 Mpa

Pmax = 3766.37 kN
gp,unfav = 1.2

As = 1558.5 mm2

Clear cover = 45 mm
Crack width = 0.25 mm under 0.85*UTS
Reinforcement stress limited to = 250 Mpa to avoid crack width check.
To avoid crack check, stresses in reinforcement can be restricted to 250 Mpa
As,revised 1558.5x435/250 = 2711.79 mm2

Provide 16 mm dia bar, provide a 8 turn spiral round to each anchorage,


over a distance of 2Yo = 480 mm from loaded face as per catlouge of M/S Dynamic prestress for 19 T 13
Area of steel provided = 3216.99 mm2

Hence, Provided spiral reinforcemnt OK

Reinforcement to Resist Spalling As Per IRC SP:105 Example:

EPC Contractor-M/s Krishna Constructions 291


Design ch-109+720
Design of PSC Girder

Reinforcement required = 0.03 x Pmax/fyd x gp,unfav


As, req = 0.03 x 3766.37 x 10^3 /250
= 542.357 mm2

Provide 3 Nos. of 16 dia as both horizontal & verical


Area of steel provided 603.1858 mm2 > 542.357 mm2 OK

EPC Contractor-M/s Krishna Constructions 292


Design ch-109+720
Design of PSC Girder

Design of End Diaphgram (Jack Up condition)

Summary of forces for End Cross-Girder

Flange part is ignored in design

0.22 Effective span of End Cross girder (L) = 3.19253 m

L/D Ratio = 1.376092 < = 2.5 (For continuous beam)


2.32 Design as deep beam
2.1
Lever arm, z = 1.334507 m

0.426

All the Girders are not supported on bearing and the reaction is not transferred to it directly. Hence, End Diaphragm is critical in service condition.
The reactions below the each girder due to SIDL & DL has been calculated with the help of STAAD.

Jack Up Condition :
Hogging Moment (Tm ) Sagging Moment (Tm ) Shear Force ( T )
Force due to Load Factor Load Factor Load Factor
(At Beam. 91 2nd node)ULS SLS R SLS Q (At Beam. 92 2nd node)
ULS SLS R SLS Q (At Beam. 91 2nd node)
ULS SLS R SLS Q
DL 83 1.35 1 1 36 1.35 1 1 93 1.35 1 1
SIDL 14 1.35 1 1 2 1.35 1 1 12 1.35 1 1
Surfacing 11 1.75 1 1 4 1.75 1 1 11 1.75 1 1

Design Bending Moment


Hogging Sagging Shear Force
Load Combination Tm Tm Tonne
ULS 150.2 58.3 161
SLS Rare 108 42 116
SLS Quasi Permanent 108 42 116

EPC Contractor-M/s Krishna Constructions 293


Design ch-109+720
Design of PSC Girder

MATERIAL PROPERTIES :
Grade of concrete = M 40 MPa PERMISSIBLE STRESSES
Grade of Reinforcement = Fe 500 MPa 1) Permissble concrete compressive stresses
fywd = 0.8 fyk = 400 MPa Load Combi Permissble Stress
Clear cover = 50 mm SLS Rare 0.48 fck = 19.2 Mpa
Modulus of Elasticity steel Es = 200000 Mpa SLS QP 0.36 fck = 14.4 Mpa
For short Term loading Ecm = 35000 Mpa
Creep factor f = 1.65773 */ Refer appendix A2
For long Term loading Ecm' = 13169.2 Mpa
fcteff Mean tensile strength = fctm = 3.51517 Mpa 2) Permissible Tensile stress in steel (Rare) = 300 Mpa
fcd = 22.3333 Mpa Permissible Tensile stress in steel (Quasi) = 400 Mpa
euk = 0.0025
eud = 0.00225 3) Permissible crack width wk
ecu2 = 0.0035 SLS QP Load combination = 0.3 mm
xumax/d = 0.6087

DESIGN OF SECTION HOGGING MOMENT DESIGN OF SECTION SAGGING MOMENT


Width bw = 426 mm Width bw = 426 mm
Overall depth D = 2320 mm Overall depth D = 2320 mm
Effective depth provided d = 2254 mm Effective depth provided d = 2254 mm
Zone of reinforcement :- Zone of reinforcement :-
Depth in which reinforcement is to be provided = 1.856 m Depth in which reinforcement is to be provided = 0.42037 m
(0.8D) (0.25D - 0.05L)

Let us provide Ast top Let us provide Ast bottom


Layer-1 32 f 4 Nos. @ 98 mm c/c Layer-1 32 f 4 Nos. @ 98 mm c/c
Layer-2 32 f 4 Nos. @ 98 mm c/c Layer-2 32 f 4 Nos. @ 98 mm c/c

Ast,provided = 6433.98 mm2 Ast,provided = 6433.98 mm2

EPC Contractor-M/s Krishna Constructions 294


Design ch-109+720
Design of PSC Girder

A) ULS CAPACITY CHECK


Check Check Check

MED b d Ast, Provided


xmax xu = 0.87 fyk
Check
Ast / 0.362
Ast,calfck
=M/
b (0.87 fyk *z)
Ast min DFd z MED/z +DFD
MRd =0.87MRD/z
fyk Ast *z
Load comb. Tm mm mm mm2 mm mm mm2 Ast Calc.<Astmm2
ProvidedAst,provided
T > Ast min
m T Tm Tm/m MRD/z > MED/z +DFD

ULS Hogging 150.2 426 2254 6433.98 1372 193.286 UR, OK 2587.38 OK 1440.31 OK 80.5 1334.51 193.051 373.499 279.878 OK

ULS Sagging 58.3 426 2254 6433.98 1372 193.286 UR, OK 1004.29 OK 1440.31 OK 80.5 1334.51 124.187 373.499 279.878 OK

B) SLS STRESS CHECK


Rare Load Combination Formula used for calculation of stress
Ec,eq = Ecm*(MQP+MST) dc (depth of neutral axis) = -m*As + Ö ( m2 * As2 + 2* m*As*b* d )
MST +(1+f)* MQP b
MST = MRARE -MQP INA (Transformed) = b *dc3/3 + m* As *(d-dc)2
m = Es/ Ec,eq
Compressive stress in concrete sc = MRARE* dc / INA
Quasi Permanent Load Combination Tensile stress in steel ss = m* MRARE* (d - dc ) / INA
m = Es / Ecm'

EPC Contractor-M/s Krishna Constructions 295


Design ch-109+720
Design of PSC Girder

Stress Check for SLS Load Combinations

Load comb. M b d Ast, Provided N.A. depthINA


(dc) Comp stress
Max C. Stress Tensile stress
Max T Stress
(tm/m) mm mm mm2 modular ratio
mm mm4 Mpa Mpa Check Mpa Mpa Check

Check for Hogging Moment


SLS (R Comb.) 108 426 2254 6433.98 15.187 573.136 3E+11 2.04419 19.2 OK 91.0477 300 OK

SLS (QP Comb.) 108 426 2254 6433.98 15.187 573.136 3E+11 2.04419 14.4 OK 91.0477 400 OK

Check for Sagging Moment


SLS (R Comb.) 42 426 2254 6433.98 15.187 573.136 3E+11 0.79496 19.2 OK 35.4074 300 OK

SLS (QP Comb.) 42 426 2254 6433.98 15.187 573.136 3E+11 0.79496 14.4 OK 35.4074 400 OK

C) SLS CRACK WIDTH CHECK (QUASI PERMANENT LOAD COMBINATION)


1) CHECK Ast,min for crack control
b h d Act =bh/2 ss = fyk k kc h k
Load comb.
mm mm mm mm2 Mpa As,min =kc k fct,eff Act
As,provided
/ ss check 0 1
0.3 1
Check for Hogging Moment 0.8 0.65
SLS QP 426 2320 2254 494160 500 0.65 0.4 903.2695 6433.98 OK 3 0.65

Check for Sagging Moment


SLS QP 426 2320 2254 494160 500 0.65 0.4 903.2695 6433.98 OK

EPC Contractor-M/s Krishna Constructions 296


Design ch-109+720
Design of PSC Girder

2) CHECK FOR MAXIMUM SPACING b/w bars.


Spacing b/w bars
Load comb. Bar dia cover Provided Calculatedcheck
feq c mm mm

Check for Hogging Moment


SLS QP 32 50 98 330 OK

Check for Sagging Moment


SLS QP 32 50 98 330 OK

3) CHECK FOR CRACK WIDTH

Load comb. hc,eff =Min [ 2.5 ( hAceff


- d ) ,=(hc,eff
h - x/3
Asprovided
*b) , h/2] rpeff = As/Ac,eff
smax =3.4cssc
+ 0.17 f x/rPeff
=neutralktaxis depth ae = Es/Ecm'
esm - ecm =Max [ [ wk
ssc - kt fct,eff
check( 1+ ae rP,eff ) / rP,eff ] /Es , 0.6ssc/Es ]
mm mm2 mm2 mm Mpa mm

Check for Hogging Moment


SLS QP 165 70290 6433.98 0.09153 229.431 91.0477 573.136 0.5 15.187 0.00027 0.06267 OK

Check for Sagging Moment


SLS QP 165 70290 6433.98 0.09153 229.431 35.4074 573.136 0.5 15.187 0.00011 0.02437 OK

D) CHECK FOR SHEAR : ( IRC 112 / clause 10.3.2 (2) )


Check of Shear Reinforcement Requirement

Load comb. VED b bVED d bw k= Min [ 1Asl


+ Ö200/dr1, 2= ]Min [nmin
Asl/bw
= 0.031
d , 0.02
scp
k3/2
] fck1/2
VRdc =Max [ ( 0.12 kCheck
(80 r1 fck )0.33 + 0.15 scp ) bw d , (nmin +0.15scp ) bw d ]
T T mm mm mm2 Mpa Tonne

ULS 161 1 161 2254 426 1.29788 6433.98 0.0067 0.289896 0 41.1241
Provide shear reinf.

EPC Contractor-M/s Krishna Constructions 297


Design ch-109+720
Design of PSC Girder

Check for Maximum Shear Capacity :

Load comb. VED bw d z =0.9d acw n1 Vrdmax = acw * bw Check


* z * n1 * fcd
q =/20.5 sin-1 [ 2*VNSq /adopted
(acw * bw * z * v1 * fcd) ]
T mm mm mm Tonne deg deg

ULS 161 426 2254 2028.6 1 0.6 579.003 OK 8.07235 45

FINDING DESIGN SHEAR REINFORCEMENT REQUIREMENT

Provide Asw Asw/s provide


Load comb. VED bw z qdesign Asw/s = VED / z fywd
rw,min
cotq =( Asw,min
0.072 √ fck
=Legs
rw,min*s
) / fyk *bw
dia spacing DFd = 0.5 VED cotq
T m m deg mm2/m mm2/m nos mm mm mm2/m Check T

ULS 161 426 2028.6 45 1984.13 0.00091 58.196 2 20 150 4188.79 OK 80.5

DFd = Additional Tensile force, to be accounted in longitudinal reinforcement

EPC Contractor-M/s Krishna Constructions 298


Design ch-109+720
Design of PSC Girder

Design of Intermediate Diaphgram

Summary of forces for Intermediate Cross-Girder

Flange part is ignored in design

0.22 Intermediate Cross girder span c/c of brg. = 3.19253 m

L/D Ratio = 1.37609 < = 2.5


2.32 Design as deep beam
2.1
Lever arm, z = 1.33451 m

0.319

Service Condition :
Hogging Moment (Tm ) Sagging Moment (Tm ) Shear Force ( T )
Force due to Load Factor Load Factor Load Factor
(At Beam. 91 2nd node)
ULS SLS R SLS Q (At Beam. 92 2nd node)
ULS SLS R SLS Q (At Beam. 91 2nd node)
ULS SLS R SLS Q
DL 1 1.35 1 1 18 1.35 1 1 10 1.35 1 1
SIDL 40 1.35 1 1 0 1 1 1 8 1.35 1 1
Surfacing 2 1.75 1 1 0 1.75 1 1 1 1.75 1 1
Live Load 28 1.5 1 0 75 1 1 0 18 1 1 0

Design Bending Moment


Hogging Sagging Shear Force
Load Combination Tm Tm Tonne
ULS 100.85 99.3 44.05
SLS Rare 71 93 37
SLS Quasi Permanent 43 18 19

EPC Contractor-M/s Krishna Constructions 299


Design ch-109+720
Design of PSC Girder

MATERIAL PROPERTIES :
Grade of concrete = M 40 MPa PERMISSIBLE STRESSES
Grade of Reinforcement = Fe 500 MPa 1) Permissble concrete compressive stresses
fywd = 0.8 fyk = 400 MPa Load Combi Permissble Stress
Clear cover = 50 mm SLS Rare 0.48 fck = 19.2 Mpa
Modulus of Elasticity steel Es = 200000 Mpa SLS QP 0.36 fck = 14.4 Mpa
For short Term loading Ecm = 35000 Mpa
Creep factor f = 1.65773 */ Refer appendix A2
For long Term loading Ecm' = 13169.2 Mpa
fcteff Mean tensile strength = fctm = 3.51517 Mpa 2) Permissible Tensile stress in steel (Rare) = 300 Mpa
fcd = 22.3333 Mpa Permissible Tensile stress in steel (Quasi) = 400 Mpa
euk = 0.0025
eud = 0.00225 3) Permissible crack width wk
ecu2 = 0.0035 SLS QP Load combination = 0.3 mm
xumax/d = 0.6087

DESIGN OF SECTION HOGGING MOMENT DESIGN OF SECTION SAGGING MOMENT


Width bw = 319 mm Width bw = 319 mm
Overall depth D = 2320 mm Overall depth D = 2320 mm
Effective depth provided d = 2254 mm Effective depth provided d = 2254 mm
Zone of reinforcement :- Zone of reinforcement :-
Depth in which reinforcement is to be provided Depth in which reinforcement is to be provided = 420.3733
0.2D will contain = 0.5*(L/D-0.5) = 43.8046 % reinf. (0.25D - 0.05L)
placed at 464 from top
0.3D on either side of mid will contain rest = 56.1954 % reinf.
placed for 696 on either side of mid

Let us provide At top Let us provide At bottom


Layer-1 32 f 4 Nos. @ 62.3333 mm c/c Layer-1 32 f 4 Nos. @ 62.33333 mm c/c
Layer-2 32 f 4 Nos. @ 62.3333 mm c/c Layer-2 32 f 4 Nos. @ 62.33333 mm c/c
Ast,provided = 6433.98 mm2 Ast,provided = 6433.98 mm2

EPC Contractor-M/s Krishna Constructions 300


Design ch-109+720
Design of PSC Girder

A) ULS CAPACITY CHECK


Check Check Check

MED b d Ast, Provided


xmax xu = 0.87 fyk
Check
Ast / 0.362
Ast,calfck
=M/
b 0.87 fykAst
*z min DFd z MED/z +DFD
MRd =0.87 MRD/z
fyk Ast (d-0.416 xu)
Load comb. Tm mm mm mm2 mm mm mm2 mm2
Ast Calc.<Ast Provided
Ast,provided
T > Ast min
m T Tm Tm/m MRD/z > MED/z +DFD

ULS Hogging 100.85 319 2254 6433.98 1372 193.286 UR, OK 1737.26 OK 1078.54 OK 22.025 1334.507 97.596 373.4993 279.878 OK

ULS Sagging 99.3 319 2254 6433.98 1372 193.286 UR, OK 1710.56 OK 1078.54 OK 22.025 1334.507 96.4345 373.4993 279.878 OK

B) SLS STRESS CHECK


Rare Load Combination Formula used for calculation of stress
Ec,eq = Ecm*(MQP+MST) dc (depth of neutral axis) = -m*As + Ö ( m2 * As2 + 2* m*As*b* d )
MST +(1+f)* MQP b
MST = MRARE -MQP INA (Transformed) = b *dc3/3 + m* As *(d-dc)2
m = Es/ Ec,eq
Compressive stress in concrete sc = MRARE* dc / INA
Quasi Permanent Load Combination Tensile stress in steel ss = m* MRARE* (d - dc ) / INA
m = Es / Ecm'

EPC Contractor-M/s Krishna Constructions 301


Design ch-109+720
Design of PSC Girder

Stress Check for SLS Load Combinations

Load comb. M b d Ast, Provided N.A. depthINA


(dc) Comp stress
Max C. Stress Tensile stress
Max T Stress
(tm/m) mm mm mm2 modular ratio
mm mm4 Mpa Mpa Check Mpa Mpa Check

Check for Hogging Moment


SLS (R Comb.) 71 319 2254 6433.98 11.4513 507.327 2.4E+11 1.50924 19.2 OK 59.5027 300 OK

SLS (QP Comb.) 43 319 2254 6433.98 15.187 573.136 3E+11 0.83235 14.4 OK 37.0726 400 OK

Check for Sagging Moment


SLS (R Comb.) 93 319 2254 6433.98 7.54772 421.837 1.7E+11 2.29426 19.2 OK 75.2105 300 OK

SLS (QP Comb.) 18 319 2254 6433.98 15.187 573.136 3E+11 0.34843 14.4 OK 15.5188 400 OK

C) SLS CRACK WIDTH CHECK (QUASI PERMANENT LOAD COMBINATION)


1) CHECK Ast,min for crack control
b h d Act =bh/2 ss = fyk k kc h k
Load comb. mm mm mm mm2 Mpa As,min =kc k fct,eff As,provided
Act / ss check 0 1
0.3 1
Check for Hogging Moment 0.8 0.65
SLS QP 319 2320 2254 370040 500 0.65 0.4 676.392 6433.98 OK 3 0.65

Check for Sagging Moment


SLS QP 319 2320 2254 370040 500 0.65 0.4 676.392 6433.98 OK

EPC Contractor-M/s Krishna Constructions 302


Design ch-109+720
Design of PSC Girder

2) CHECK FOR MAXIMUM SPACING b/w bars.


Spacing b/w bars
Load comb. Bar dia cover Provided Calculatedcheck
feq c mm mm

Check for Hogging Moment


SLS QP 32 50 62.3333 330 OK

Check for Sagging Moment


SLS QP 32 50 62.3333 330 OK

3) CHECK FOR CRACK WIDTH

Load comb. hc,eff =Min [ 2.5 ( hAceff


- d ) ,=(hc,eff
h Asprovided
- x/3*b) , h/2]
rpeff = As/Ac,eff
smax =3.4cssc
+ 0.17 f /rPeff
x =neutralktaxis depth
ae = Es/Ecm'
esm - ecm =Max [ [ wk
ssc - kt fct,eff
check
( 1+ ae rP,eff ) / rP,eff ] /Es , 0.6ssc/Es ]
mm mm2 mm2 mm Mpa mm

Check for Hogging Moment


SLS QP 165 52635 6433.98 0.12224 214.503 37.0726 573.136 0.5 15.187 0.00011 0.023857 OK

Check for Sagging Moment


SLS QP 165 52635 6433.98 0.12224 214.503 15.5188 573.136 0.5 15.187 4.7E-05 0.009986 OK

EPC Contractor-M/s Krishna Constructions 303


Design ch-109+720
Design of PSC Girder

D) CHECK FOR SHEAR : ( IRC 112 / clause 10.3.2 (2) )


Check of Shear Reinforcement Requirement

Load comb. VED b bVED d bw k= Min [ 1Asl


+ Ö200/dr1, 2= ]Min [nmin
Asl/bw
= 0.031
d scp
, 0.02
k3/2
] fck1/2
VRdc =Max [ ( 0.12 kCheck
(80 r1 fck )0.33 + 0.15 scp ) bw d , (nmin +0.15scp ) bw d ]
T T mm mm mm2 Mpa Tonne

ULS 44.05 1 44.05 2254 319 1.29788 6433.98 0.00895 0.2899 0 33.8791
Provide shear reinf.

Check for Maximum Shear Capacity :

Load comb. VED bw d z =0.9d acw n1 Vrdmax = acw * bw Check


* z * n1 *qfcd
= 0.5
/2 sin-1 [ 2*VNSq /adopted
(acw * bw * z * v1 * fcd) ]
T mm mm mm Tonne deg deg

ULS 44.05 319 2254 2028.6 1 0.6 433.573 OK 2.91559 45

FINDING DESIGN SHEAR REINFORCEMENT REQUIREMENT

Provide Asw Asw/s provide


Load comb. VED bw z qdesign Asw/s = VED / z fywd
rw,min
cotq =( Asw,min
0.072 √ fck
=Legs
rw,min*s
) / fyk dia
*bw spacing DFd = 0.5 VED cotq
T m m deg mm2/m mm2/m nos mm mm mm2/m Check T

ULS 44.05 319 2028.6 45 542.862 0.00091 58.105 2 20 200 3141.59 OK 22.025

DFd = Additional Tensile force, to be accounted in longitudinal reinforcement

EPC Contractor-M/s Krishna Constructions 304


Design ch-109+720
Design of PSC Girder

Appendix A1 :

Finding Creep Coefficent for Precast girder


fck = 50 Mpa (Considering Precast Beam material)
fcm = 60 Mpa

RH = 57.5 %
ho = 340.209 mm

Calculation of fo
fo = fRH b(fcm) b(to)

fRH = 1+ 1 - RH/100 for fcm ≤ 45 Mpa


0.1 ( ho )1/3

1+ 1 - RH/100 for fcm > 45 Mpa


0.1 ( ho )1/3 a1 * a2

a1 = [ 43.75 / fcm ]0.7


a2 = [ 43.75 / fcm ]0.2
b(fcm) = 18.78 / √fcm
b(to) = 1/ (0.1+ to0.2)
Loading age a1 a2 fRH b(fcm) b(to) fo
14 0.80164 0.93878 1.39694 2.42449 0.55704 1.88661
28 0.80164 0.93878 1.39694 2.42449 0.48845 1.65432
35 0.80164 0.93878 1.39694 2.42449 0.46813 1.58549
63 0.80164 0.93878 1.39694 2.42449 0.41838 1.417
64 0.80164 0.93878 1.39694 2.42449 0.41712 1.41273
92 0.80164 0.93878 1.39694 2.42449 0.38905 1.31767
36500 0.80164 0.93878 1.39694 2.42449 0.12085 0.40932

Calculation of f (t, to)


f (t, to) = fo bc( t , to )
bc( t , to) = [ (t-to) / (bH +t -to) ]0.3

bH = Min 1.5 [ 1+ (0.012 RH)18 ] ho +250 for fcm ≤ 35 Mpa


1500

Min 1.5 [ 1+ (0.012 RH)18 ] ho +250 a3 for fcm > 35 Mpa


1500* a3

a2 = [ 43.75 / fcm ]0.5

EPC Contractor-M/s Krishna Constructions 305


Design ch-109+720
Design of PSC Girder

Stages I II III IV V
Loading At age 14 28 35 63 64
fo 1.88661 1.65432 1.58549 1.417 1.41273
At age a2 bH bc( t , to) f (t, to) bc( t , to) f (t, to) bc( t , to) f (t, to) bc( t , to) f (t, to) bc( t , to) f (t, to)
days

14 0.85391 724.433 0 0
28 0.85391 724.433 0.30433 0.57415 0 0
35 0.85391 724.433 0.34272 0.64658 0.2479 0.41011 0 0
63 0.85391 724.433 0.43705 0.82454 0.39726 0.65719 0.37257 0.5907 0 0
64 0.85391 724.433 0.43954 0.82923 0.40047 0.66251 0.37636 0.59672 0.13862 0.19642 0 0
92 0.85391 724.433 0.49694 0.93753 0.47079 0.77883 0.45593 0.72287 0.37636 0.53331 0.37257 0.52634
36500 0.85391 724.433 0.99412 1.87551 0.99412 1.64458 0.99412 1.57616 0.99411 1.40866 0.99411 1.40441

EPC Contractor-M/s Krishna Constructions 306


Design ch-109+720
Design of PSC Girder

Appendix A1 :

Finding Creep Coefficent for End cross girder


fck = 40 Mpa
fcm = 50 Mpa

RH = 57.5 %

Cross-sectional Area Ac = 0.98832 m2


Perimeter in contact with atmosphere u = 4.626 m
Notational size ho 2Ac/u = 427.289 mm

to = 57 days Loading age

t = 36465 days

Calculation of fo
fo = fRH b(fcm) b(to)

fRH = 1+ 1 - RH/100 for fcm ≤ 45 Mpa


0.1 ( ho )1/3

1+ 1 - RH/100 for fcm > 45 Mpa


0.1 ( ho )1/3 a1 * a2

a1 = [ 43.75 / fcm ]0.7 = 0.91076


a2 = [ 43.75 / fcm ]0.2 = 0.97365
b(fcm) = 18.78 / √fcm = 2.65589
b(to) = 1/ (0.1+ to0.2) = 0.42648

fRH = 1.47401
fo = 1.66959

Calculation of f (t, to)


f (t, to) = fo bc( t , to )
bc( t , to) = [ (t-to) / (bH +t -to) ]0.3

bH = Min 1.5 [ 1+ (0.012 RH)18 ] ho +250 for fcm ≤ 35 Mpa


1500

Min 1.5 [ 1+ (0.012 RH)18 ] ho +250 a3 for fcm > 35 Mpa


1500* a3

a2 = [ 43.75 / fcm ]0.5

EPC Contractor-M/s Krishna Constructions 307


Design ch-109+720
Design of PSC Girder

fo = 1.66959

a2 = 0.93541

bH = 875.593

bc( t , to) = 0.9929

f (t, to) = 1.65773

EPC Contractor-M/s Krishna Constructions 308


Design ch-109+720
Design of PSC Girder

APPENDIX B1

SHRINKAGE CALCULATION: PRECAST T-BEAM


CALCULATION OF BASIC DRYING SHRINKAGE STRAIN FOR PRECAST BEAM
fck = 50 Mpa
fcm = 60 Mpa
ecd.¥ = kh ecd.0
ecd.0 = 0.85 [ (220+110 ads1) exp(-ads2. fcm /fcmo ) ] 10-6 bRH

bRH = 1.55 [ 1 - RH / RHo ]3

RH = 57.5 % RH0 = 100 %


bRH = 1.25533

ads1 = 4 for normal cement ads2 = 0.12 for normal cement

fcmo = 12.5 Mpa ecd.0 = 0.0004

Calculating Notational size ho


Cross-sectional Area Ac = 0.944688 m2 (Precast Beam considered)
Perimeter in contact with atmosphere u = 6.317275 m
Notational size ho 2Ac/u = 299.0807 mm

Final autogenonus shrinkage


eca,¥ = 2.0 *(fck-12.5)*10-6
= 7.5E-05

At day Autogeneious Shrinkage Drying Shrinkage ecs ,P,( t )


bas(t) eca ,P,( t )ecd, 0 ts bds(t,ts) ho kh ecd ,P, ( t )
( t - ts )
eca ,P, ¥ 1 - exp(-0.2
bas(t)
√t ) * eca, ¥ days (t-ts) + 0.04 √ ho3 mm bds(t,ts)*kh*ecd, 0 eca,P (t) + ecd,P (t)
0.1 7.5E-05 0.06129 4.6E-06 0.0004 1 -0.004369113 299.081 0.75092 -1.3E-06 3.3E-06

14 7.5E-05 0.52684 4E-05 0.0004 1 0.059120075 299.081 0.75092 1.8E-05 5.7E-05

28 7.5E-05 0.65295 4.9E-05 0.0004 1 0.115438158 299.081 0.75092 3.4E-05 8.3E-05

35 7.5E-05 0.69371 5.2E-05 0.0004 1 0.141142402 299.081 0.75092 4.2E-05 9.4E-05

63 7.5E-05 0.79555 6E-05 0.0004 1 0.230576303 299.081 0.75092 6.9E-05 0.00013

64 7.5E-05 0.7981 6E-05 0.0004 1 0.233427166 299.081 0.75092 6.9E-05 0.00013

92 7.5E-05 0.85315 6.4E-05 0.0004 1 0.305480387 299.081 0.75092 9.1E-05 0.00015

36500 7.5E-05 1 7.5E-05 0.0004 1 0.994363535 299.081 0.75092 0.0003 0.00037

Girder age Deck age


Days esh Days esh
0.1 3.3E-06 0.1 2.6E-06
14 5.7E-05 0.1 2.6E-06
28 8.3E-05 0.1 2.6E-06
35 9.4E-05 0.1 2.6E-06
63 0.00013 28 5.7E-05
64 0.00013 29 5.8E-05
92 0.00015 57 8.4E-05
36500 0.00037 36465 0.00036

EPC Contractor-M/s Krishna Constructions 309


Design ch-109+720
Design of PSC Girder

APPENDIX B2

SHRINKAGE CALCULATION: CAST-IN-SITU DECK


CALCULATION OF BASIC DRYING SHRINKAGE STRAIN FOR DECK SLAB

fck = 40 Mpa
fcm = 50 Mpa

RH = 57.5 % RH0 = 100 %


bRH = 1.25533

ads1 = 4 for normal cement ads2 = 0.12 for normal cement


fcmo = 12.5 Mpa

ecd.0 = 0.00044

Calculating Notational size ho


Cross-sectional Area Ac = 0.5728 m2
Perimeter in contact with atmosphere u = 2.60362 m2
Notational size ho 2Ac/u = 440 mm

Final autogenonus shrinkage eca,¥ = 2.0 *(fck-12.5)*10-6


= 5.5E-05

Autogeneious Shrinkage Drying Shrinkage ecs ,P,( t )


bas(t) eca ,P,( t ) ecd, 0 ts bds(t,ts) ho kh ecd ,P, ( t )
( t - ts )
Precast girder
Deckage
age eca ,P, ¥ 1 - exp(-0.2 bas(t)
√t ) * eca, ¥ days (t-ts) + 0.04 √ ho3 mm bds(t,ts)*kh*ecd, 0 eca,P (t) + ecd,P (t)

0.1 0.1 5.5E-05 0.061287 3.37E-06 0.00044 1 -0.002443788 440 0.715 -7.61E-07 2.61E-06

14 0.1 5.5E-05 0.061287 3.37E-06 0.00044 1 -0.002443788 440 0.715 -7.61E-07 2.61E-06

28 0.1 5.5E-05 0.061287 3.37E-06 0.00044 1 -0.002443788 440 0.715 -7.61E-07 2.61E-06

35 0.1 5.5E-05 0.061287 3.37E-06 0.00044 1 -0.002443788 440 0.715 -7.61E-07 2.61E-06

63 28 5.5E-05 0.652955 3.59E-05 0.00044 1 0.068150718 440 0.715 2.12E-05 5.71E-05

64 29 5.5E-05 0.659395 3.63E-05 0.00044 1 0.070496877 440 0.715 2.2E-05 5.82E-05

92 57 5.5E-05 0.779083 4.28E-05 0.00044 1 0.131708702 440 0.715 4.1E-05 8.39E-05

36500 36465 5.5E-05 1 0.000055 0.00044 1 0.989976953 440 0.715 0.000308 0.000363

Days esh
0.1 2.6E-06
0.1 2.6E-06
0.1 2.6E-06
0.1 2.6E-06
28 5.7E-05
29 5.8E-05
57 8.4E-05
36465 0.00036

EPC Contractor-M/s Krishna Constructions 310


Design ch-109+720
Design of PSC Girder

APPENDIX C1

MATERIAL PROPERTIES OF REINFORCING STEEL & CONCRETE


REINFORCEMENT PROPERTIES :
Grade of steel = 500 Mpa

Es = 200000 Mpa

fyk = 500 Mpa


fyd = 434.783 Mpa
ft = 545 MPa

gs = 1.15

fyd = fyk / gs Stress


= 434.783 Mpa

eyk = fyk / Es eyd = 0.00217 eud = 0.00405


= 0.0025 Mpa Strain

eyd = fyd / Es Design stress- strain diagram for Reinforcing Steel


= 0.00217 Mpa

euk = 0.0045

eud = 0.9 * euk


= 0.00405

fy = es*Es if es < eyd


= fyd if es >= eyd

Es = Modulus of Elasticity
fyk = Characteristics yield strength of reinforcement
ft = Tensile strength of steel
gs = Partial factor for reinforcing steel
fyd = Design yield strength of reinforcement
eyk = Characteristic yield strain of reinforcement steel
eyd = Design yield strain of reinforcement steel
euk = Characteristic strain of reinforcement steel at maximum load
eud = design strain of reinforcement steel at maximum load

EPC Contractor-M/s Krishna Constructions 311


Design ch-109+720
Design of PSC Girder

PROPERTY OF CONCRETE (PRECAST BEAM):

Concrete Grade = 50
fcd = 22.3333 Mpa
fck = 50 Mpa
fcd = afck /gm

a = 0.67 stress
gm = 1.5 ec2 = 0.002 ecu2 = 0.0035
strain
fcd = 0.44667 *fck
= 22.3333 Mpa Design stress -strain diagarm for Concrete

fcm = fck+10 (fck & fcm) in Mpa


= 60 Mpa

fctm = 0.259 fck2/3 for fck ≤ 60 Mpa


= 2.27 ln[1 + fcm/12.5)] for fck > 60 Mpa

fctm = 3.51517 Mpa

ec2 = (2+0.085 ( 0.8 fck - 50 )0.53)/10 For fck > 60 Mpa


0.2 % For fck <= 60 Mpa

= 0.002

ecu2 = (2.6 + 35 [ ( 90 - 0.8*fck ) / 100 ]4)/10 For fck > 60 Mpa


0.35 % For fck <= 60 Mpa

= 0.0035

Stress in concrete corresponding to starin


sc = fcd * ( 1 - (1-ec/ec2)h ) For 0 ≤ ec ≤ 0.002
= fcd For 0.002 ≤ ec ≤ 0.0035

h = 1.4 + 23.4 [ ( 90 - 0.8*fck ) / 100 ]4 For fck > 60 Mpa


2 For fck <= 60 Mpa

= 2

EPC Contractor-M/s Krishna Constructions 312


Design ch-109+720
Design of PSC Girder

Property of Rectangular stress block


hfcd
Effective height factor l = 0.8 for fck <= 60 Mpa
= 0.8- (fck-60)/500 for 60 < fck <= 110 Mpa
= 0.8

Compression zone factor h = 1 for fck <= 60 Mpa


= 1- (fck-60)/250 for 60 < fck <= 110 Mpa
= 1

0.0035 Strain fcd 1 *fcd 0.97306 *fcd


3/7x 0.41597 x
0.002 Stress
@ 0.8 *x 0.83193 *x
x 4/7x

Strain
Recatangular- Parabolic stress block Equavelent stress block Actaul modification

Limiting Depth of Neutral axis


Minimum Strain in reinforcement at ultimate limit state
eud = 0.00405

Ultimate strain in concrete ecu2 = 0.0035

ecu2 = 0.0035

xu ≤xu,max
d
d-xu

eud= 0.00405
Ast

xu,max 0.0035
d - xu,max= 0.00405

xu,max = 0.46358 * d

EPC Contractor-M/s Krishna Constructions 313


Design ch-109+720
Design of PSC Girder

Modifed Linear stress sreain curve for concrete

fcd = 22.3333 Mpa

stress
ec3 = 0.0018 ecu3 = 0.0035
strain

Modified Design stress -strain diagarm for Concrete

ec3 = 0.0018 For fck<= 60 Mpa


ecu3 = 0.0035

fc = fcd/ec3 *ec For 0 ≤ ec ≤ 0.0018


For 0.0018 ≤ ec ≤ 0.0035

fck = Characteristic compressive cube strength of concrete at 28 days


fcd = Design Value of concrete compressive strength
ec2 = Strain at reaching characteristic
ecu2 = Ultimate strain

ec = Compressive strain in concrete


sc = Compressive stress in concrete

EPC Contractor-M/s Krishna Constructions 314


Design ch-109+720
Design of PSC Girder

APPENDIX C2

PRESTRESSING STEEL PROPERTY PROPERTIES :

Ep = 195000 Mpa

fpk = 1861 Mpa


fpd = 1407.887 Mpa
fp0.1k = 1619.07 MPa

gs = 1.15

fpd = fp0.1k / gs Stress


= 1407.887 Mpa

epd = fyd / Es eyd = 0.00722 eud = 0.02


= 0.00722 Mpa Strain

Design stress- strain diagram for Prestressing Steel


euk = 0.022222

eud = 0.9 * euk


= 0.02

fp = ep*Ep if ep < epd


= fpd if ep >= epd

Ep = Modulus of Elasticity
fpk = Characteristics tensile strength of prestressing steel

gs = Partial factor for reinforcing steel


fpd = design yield strength of prestressing steel

epd = Design yield strain of prestressing steel


euk = Characteristic strain of prestressing steel at maximum load
eud = design strain of prestressing steel at maximum load

EPC Contractor-M/s Krishna Constructions 315