Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

GENERAL NOTES:

1. THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ALL RELEVANT


ARCHITECTS AND ENGINEERS DRAWINGS AND SPECIFICATIONS.

2. DO NOT SCALE THIS DRAWING. ANY AMBIGUITIES, OMISSIONS AND ERRORS


ON DRAWINGS SHALL BE BROUGHT TO THE ENGINEERS ATTENTION
IMMEDIATELY. ALL DIMENSIONS MUST BE CHECKED / VERIFIED ON SITE.
OP CL CL

FINISHES TO ARCHITECTS DETAILS


19 FINISHES TO ARCHITECTS DETAILS 25 150
3. ALL DIMENSIONS ARE IN MILLIMETRES UNLESS NOTED OTHERWISE.
25
TOS 25 26 25 35 70 35 TOS STEEL COLUMN SCHEDULE 4. FOR GENERAL NOTES REFER TO DRAWING: 073707-CUR-ZZ-XX-DR-S-20001.
SSL +92.000 m ROOFDEK D35 SPANS BETWEEN ROOF ROOFDEK D35 SPANS BETWEEN ROOF 10mm THK
SSL +92.000 m
Level 05 PURLINS Level 05 PURLINS STEEL PLATE REF. SIZE 5. CONCRETE GRADES:

50 100 50 75

50 100 50 75
100

100
92.000 m 92.000 m SC1 SRC305x305x118 • RC SLABS C40/50
4 No. M12 BOLTS
6 SC2 UC152x152x23 • RC COLUMNS AND WALLS C50/60
1000
SC3 SHS200x200x12.5 • RC BEAMS C40/50

200

200
2 No. M12 BOLTS • FOUNDATIONS C35/45

SHS COLUMN
SC4 SHS150x150x12.5
HB1 ROOF PURLINS @1000 c/c Z202
SB5 METSEC OR SIMILAR NOTES:

UC
APPROVED PLAN BRACING SCHEDULE
SB5 126
1105 BOS +91.396 m HB1 ROOF PURLINS @1000 c/c Z202 STEEL BEAM STEEL BEAM REF. SIZE • TO LOWER THE POSSIBILITY OF THE SULPHATES ATTACK ON
BOS +91.396 m THE CONCRETE, SULPHATE RESISTING CEMENT MIX SHOULD BE USE
METSEC OR SIMILAR 4 No. M12 BOLTS HB1 CHS60.3x3.2
APPROVED IN CONCRETE WHERE IN CONTACT WITH AGGRESSIVE GROUND.
10mm THK FIN PLATE SULPHATE RESISTING CONCRETE CLASS TBC. PENDING SI REPORT
LABORATORIES RESULTS;
STEEL BEAM SCHEDULE
SECTION 1-1 SECTION 2-2 REF. SIZE COMMENTS
• FOR THE INTEGRAL WATERPROOF CONCRETE STRUCTURES LIQUID
ADMIXTURE WILL BE IN USE. FOR DETAILS AND SPECIFICATIONS
SCALE: 1 : 20 SCALE: 1 : 20 TYPICAL STEEL BEEAM TO SB1 UB838x292x194 REFER TO ARCHITECTS AND SPECIALIST DOCUMENTS AND DETAILS.

COLUMN CONNECTION SB2


SB3
UC356x406x634
UB356x127x33
SCALE: 1 : 10 SB4 UB203x133x30
SB5 UB305x127x37
SB6 SHS150x150x6.3
SB7 UC305x305x240
SB8 UC305x305x97
WITH 2No. 30 THK PLATES
SB9 UC356x406x340 WELDED TO FLANGES
WITH 2No. 30 THK PLATES
SB10 2 x UC356x406x340 WELDED TO FLANGES

P03 STAGE 3 ISSUE 22/05/20 NJ SE


P02 PRELIMINARY - DESIGN COORDINATION IN PROGRESS 27/04/20 NJ SE
P01 ISSUED FOR COMMENTS 17/04/20 NJ SE
Rev: Description: Date: By: Chkd:

40 Compton Street, London, EC1V 0BD


020 7324 2240
london@curtins.com
www.curtins.com
Civils & Structures • Transport Planning • Environmental • Infrastructure • Geotechnical • Conservation & Heritage • Principal Designer
Birmingham • Bristol • Cambridge • Cardiff • Douglas • Dublin • Edinburgh • Glasgow • Kendal • Leeds • Liverpool • London • Manchester • Nottingham

Status:

SUITABLE FOR STAGE APPROVAL S4


Project:

CAMDEN AND ISLINGTON NEW


MENTAL HEALTH FACILITY

Model Name:073707-CUR-00-ZZ-M3-S19-00001_CENTRAL
Drg Title:

FIFTH FLOOR SECTIONS

Size: Date: Drawn By: Designed By: Checked By:

A1 04.2020
NJ AP SE
Scale: As indicated
Project No: Originator: Volume: Level: Type: Role: Category / Number: Rev:

073707 - CUR - 00 - 05 - DR - S - 21005 - P03