General Notes:: Finishes To Architects Details Finishes To Architects Details
General Notes:: Finishes To Architects Details Finishes To Architects Details
50 100 50 75
50 100 50 75
100
100
92.000 m 92.000 m SC1 SRC305x305x118 • RC SLABS C40/50
4 No. M12 BOLTS
6 SC2 UC152x152x23 • RC COLUMNS AND WALLS C50/60
1000
SC3 SHS200x200x12.5 • RC BEAMS C40/50
200
200
2 No. M12 BOLTS • FOUNDATIONS C35/45
SHS COLUMN
SC4 SHS150x150x12.5
HB1 ROOF PURLINS @1000 c/c Z202
SB5 METSEC OR SIMILAR NOTES:
UC
APPROVED PLAN BRACING SCHEDULE
SB5 126
1105 BOS +91.396 m HB1 ROOF PURLINS @1000 c/c Z202 STEEL BEAM STEEL BEAM REF. SIZE • TO LOWER THE POSSIBILITY OF THE SULPHATES ATTACK ON
BOS +91.396 m THE CONCRETE, SULPHATE RESISTING CEMENT MIX SHOULD BE USE
METSEC OR SIMILAR 4 No. M12 BOLTS HB1 CHS60.3x3.2
APPROVED IN CONCRETE WHERE IN CONTACT WITH AGGRESSIVE GROUND.
10mm THK FIN PLATE SULPHATE RESISTING CONCRETE CLASS TBC. PENDING SI REPORT
LABORATORIES RESULTS;
STEEL BEAM SCHEDULE
SECTION 1-1 SECTION 2-2 REF. SIZE COMMENTS
• FOR THE INTEGRAL WATERPROOF CONCRETE STRUCTURES LIQUID
ADMIXTURE WILL BE IN USE. FOR DETAILS AND SPECIFICATIONS
SCALE: 1 : 20 SCALE: 1 : 20 TYPICAL STEEL BEEAM TO SB1 UB838x292x194 REFER TO ARCHITECTS AND SPECIALIST DOCUMENTS AND DETAILS.
Status:
Model Name:073707-CUR-00-ZZ-M3-S19-00001_CENTRAL
Drg Title:
A1 04.2020
NJ AP SE
Scale: As indicated
Project No: Originator: Volume: Level: Type: Role: Category / Number: Rev: