Section : 2EB14

Type : Existing Beam Check


Design Code : BS8110 , BS5950
Prepared By : Moh Date : 7/4/2020
Project Checked By : MPA Job ID :

LOADING CALCULATION

Partial Safety Factor


Steel 'γms' = 1.15
Material
Concrete 'γmc' = 1.25
Dead 'γf' = 1.40
Load
Live 'γf' = 1.60

One-way load distribution

80 87 DL L= 5.0 m
12 L 14 LL a= 3.0 m
131 143 R b= 2.0 m
a b

UDL + 1PL Load Case


Self Weight of Beam = 150 x 500 x 24.0 = 1.8 KN/m
Slab Weight (+ SDL+M&E ) (A1) = 0.5 x 4.8 x 4.0 = 9.6 KN/m
(A2) = 0.5 x 4.2 x 3.0 = 6.3 KN/m
Other = 0.5 x 0 x 0.0 = 0 KN/m
Wall Load (150 thk) = 3.0 x 3.0 x 1.0 = 9 KN/m
DLTotal = 26.7 KN/m
Imposed Load (LL) = 0.5 x 1.5 x 4.0 = 3.0 KN/m
= 0.5 x 0.0 x 3.0 = 0.0 KN/m
LLTotal = 3.0 KN/m
Wu, (DL+LL) = 42.2 KN/m
Span Length, L = 5.0 m
P1,DL SC1+2B8-1 = 22.3 + 11.05 = 33.4 KN
P1,LL SC1+2B8-1 = 5.82 + 4.48 = 10.3 KN
P1, (DL+LL) (Factored) = 63.2 KN
Vu = wL/2 + Pa/L = 143.4 KN
Mu = R*a - wa^2/2 = 202.3 KN-m