00 - Main Pump Control
00 - Main Pump Control
00 - Main Pump Control
Pt Pd Pt Pd
Pecn
Ps
7 6
NO.1 MAIN PUMP
A A
Y
Psv2B Psv2 Psv2A
B B
X Y
Z
NO.1 MAIN PUMP
1 2 3 4 5 6 7 8 9 10 11 7 6 5 4 12 13
A-A
C 14
C-C
C B-B
NO.1 Pump front servo assembly
PA1
1 Pc Pe2 Pd
Pecn
NO.1 Pump rear servo assembly
Pc
1 2 Pt
4
NO.1 Pump front servo valve
B B
A A
C C
D
Pecn Pdr PA2
E
F
G H
G H
B-B C-C D-D
F
E
B B
A A
Pdr
C D C
E
PA2 F
G Psv2
Pecn
G
PA1 D F
E
H
H
1 2 3 4 5 6 7 8 9 10
18 17 16 15 14 13 12 11
Operation in direction of increase of pump discharge amount (max. angle)
13 e h Psw
4 4A 8
A d
7 c
Pecn
NC valve
g 1 Pec
CO valve
6
Pe
j
TV valve
f
19
Psv
Operation in direction of decrease of pump discharge amount (min. angle)
13 e h Psw
4 4A 8
A d
7 c
Pecn
NC valve
g 1 Pec
CO valve
6
Pe
j
TV valve
f
19
Psv
TVC VALVE
Psv PA1 PA2
Pe Pd D
B A A
C
C-C
D
C B 1 2 3 4 5 6 7 8
F B-B
E
A-A
E D-D E-E F-F
F
When command current value from controller is small In DH and H mode
a
1
b
2
c Psv
Pecn NC CO Pe
valve valve
3
PA1
Servo valve
PA2
Servo piston
Small Large
C/V C/V 9
PA1 PA2
Pump
Prolix switch
Battery
Pump OFF
PA1 PA2 controller
ON
Resistor
Psv
When command current value from controller is small In DH and H mode
a
1
b
2
c Psv
Pecn NC CO Pe
valve valve
PA1
Servo valve
PA2
Servo piston
Small Large
C/V C/V 9
PA1 PA2
Pump
Prolix switch
Battery
Pump OFF
PA1 PA2 controller
ON
Resistor
Psv
When command current value from controller is large In DH and H mode
a
1
b
2
c Psv
Pecn NC CO Pe
valve valve
3
PA1
Servo valve
PA2
Servo piston
Small Large
C/V C/V 9
PA1 PA2
Pump
Prolix switch
Battery
Pump OFF
PA1 PA2 controller
ON
Resistor
Psv
When pump load is small in G mode (Pump prolix switch On)
a
1
b
2
c Psv
Pecn NC CO Pe
valve valve
3
PA1
Servo valve
PA2
Servo piston
Small Large
C/V C/V 9
PA1 PA2
Pump
Prolix switch
Battery
Pump OFF
PA1 PA2 controller
ON
Resistor
Psv
When pump load is large in G mode (Pump prolix switch On)
a
1
b
2
c Psv
Pecn NC CO Pe
valve valve
3
PA1
Servo valve
PA2
Servo piston
4
Small Large 5
C/V C/V 9
PA1 PA2
Pump
Prolix switch
Battery
Pump OFF
PA1 PA2 controller
ON
Resistor
Psv
No.1 Pump front CO, NC valve
No.1 Pump front CO, NC valve
7
2
8
3
9
4
10
5
A-A
A
11
Pecn
6 Pt Pdr2
12 Pc
PA1
Pe1
A
Pd
No.1 Pump rear CO, NC valve
1
7
2
3 8
4
10
5 11
6 12
A-A
A
Pc
Pecn
Pe1 Pt
Psv2 Pe2 Psv1
PA2o Pdr2
Pdr1
Pd PA21
PA1o PA11
A
FUNCTION & OPERATION OF CO VALVE
When main pump discharge pressure is lower than relief pressure
a
b
CO cancel sol.
De-energized
3
c
Pecn 4
NC Pe Psv
TVC
valve Pec valve
Servo valve PA
Servo piston
Small Large
C/V
PA1 PA2
Psv
When main pump discharge pressure become close relief pressure
a
b
CO cancel sol.
De-energized
c
Pecn 4
NC Pe Psv
TVC
valve Pec valve
Servo valve PA
Servo piston 5
Small Large
C/V
PA1 PA2
Psv
When cut-off function is cancelled by CO cancel solenoid valve
a
b
2 CO cancel sol.
Exited
6
7
c
Pecn 4
NC Pe Psv
TVC
valve Pec valve
Servo valve PA
Servo piston
Small Large
C/V
PA1 PA2
Psv
FUNCTION AND OPERATION OF NC VALVE
Jet sensor
1) When control valve is at neutral
Control
valve Pt
Pd
Pt
10
Pecn
11
Servo piston
12
Small Large
b
PA1 PA2
Psv
FUNCTION AND OPERATION OF NC VALVE
Jet sensor
2) When control valve is operated
Control
valve Pt
Pd
Pt
Pecn
11
Servo piston
Small Large
b
PA1 PA2
Psv