Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Document No.

TTU-DS-40-001-A4

PT. PERTAMINA (PERSERO)


Revision : Status :
PEKERJAAN SURVEY DAN PENYUSUNAN DOKUMEN FRONT END 2 TD
ENGINEERING DESIGN TERMINAL LPG REFRIGERATED JAWA TIMUR,
JAWA TIMUR
DATA SHEET

DATA SHEET OF BOLLARD

OWNER : PT. PERTAMINA (PERSERO)


PROJECT : PEKERJAAN SURVEY DAN PENYUSUNAN DOKUMEN FRONT END
ENGINEERING DESIGN TERMINAL LPG REFRIGERATED JAWA TIMUR,
JAWA TIMUR
LOCATION : TUBAN, JAWA TIMUR

2 26 -05-2020 TENDER DOCUMENT JW DH AS


1 20 -02-2020 TENDER DOCUMENT JW DH
0 15-01-2016 TENDER DOCUMENT WIT PWA
PT. PERTAMINA
REV. DATE DESCRIPTION
PREP’D CHK’D APP’D
DATA SHEET
TTU-DS-40-001-A4 Page 1 of 4

REVISION HISTORICAL SHEET

Rev. No. Date Description


DATA SHEET
TTU-DS-40-001-A4 Page 2 of 4

DAFTAR ISI

1. PENDAHULUAN ..................................................................................................................................... 3
2. BOLLARD ................................................................................................................................................ 3
DATA SHEET
TTU-DS-40-001-A4 Page 3 of 4

1. PENDAHULUAN

Dokumen ini berisi mengenai material data sheet Bollard yang akan digunakan di Terminal LPG
Refrigerated Tuban.

2. BOLLARD

QUALITY STANDARD
Body Body JIS G 5101 Grade 3 SC 46
Nut JIS B 1181 Grade 1 Class 3 4T, M64-6
Washer JIS B 1256 Steel bars
Foundaion Plate JIS G3101, SS41 atau JIS G5101, SC46
Baut Angkur (M24) ASTM A325 (Galvanized)
BS-3692 grade 8.8 (mild steel washer plate)
Tipe Sesuai dengan gambar T Bollard
Dimensi Sesuai spesifikasi dan gambar
Kapasitas Bollard 1. Jetty C : 35 ton
2. Jetty Tugboat : 15 ton
Proteksi Korosi Hot Dip Galvanization dilapisi marine
painting 400 mikron meter
Material Cast Iron BS-3100 Grade A1
Standar Desain BS-6349 Part 4
Factor of Safety Min. 3 (tiga)