Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

8.

0 Design for 5-Pile Group (Square group)


2
Concrete Fck,Steel Fy 25 500 N/mm
Pile Dia (hp) 450 mm
Column Dim (a,b) 1400 1400 mm
Spacing factor of piles (α) 3.1
Spacing between centers of piles (l) 1973 mm
Thickness of pile cap (h) 750 mm
Width of pile cap 2723 mm
Length of Pile Cap 2723 mm

Tensile forces to be resisted by reinforcement


Load on column (N) 28 Ton
Effective depth of pile cap (d) 675 mm

Neglecting Column Size (Nl/10d)


Tensile for to be resisted by reinforcement 8.18

Taking size of column into consideration


Parallel to X-X 6.81
Parallel to Y-Y 6.81

Tensile steel required (Sq. In) 0.68


Tensile steel required (Sq.cm) 0.68
2
Reinforcement @ 0.15% of Pile cap area X-X plane 2756.86 mm
2
Reinforcement @ 0.15% of Pile cap area Y-Y plane 2756.86 mm

Provide reinforcement in X-Direction


Bar Dia 16 mm
Number Of Bars Required 13.7
Number Of Bars Provided 20
Ast Provided 4019.2
SAFE

Provide reinforcement in Y-Direction


Bar Dia 16 mm
Number Of Bars Required 20.0
Number Of Bars Provided 25
SAFE 5025

Oneway Shear
Diagonal tension @ 0.5d distance from face of
pedestal 337.5 mm
Shear Force,VU 140 kN
Percentage of Steel,Pt 0.27 %
2
Shear strenth of concrete,Tc 0.36 N/mm
2
Shear stress,Tv 0.08 N/mm
Safe, provide nominal shear reinf

Design Shear,Vus -521647 N


Bar dia 10 78.5
Spacing of Stirrups,Sv -265.117 mm
say provide stirrups 6lgd-10Ø @ 200 mm c/c

You might also like