Professional Documents
Culture Documents
General Purpose Digital Gauge Type D1005PS, % of Span Terminal Point Accuracy
General Purpose Digital Gauge Type D1005PS, % of Span Terminal Point Accuracy
PRODUCT SPECIFICATIONS
Type no.: D1005PS Display Full Scale Display KEYPAD FUNCTIONS
Accuracy: ±0.5% of span Resolution: Numerical Value Resolution On/Off: Manually turns unit on and off (four
>=-15>0 –XX.000 options: never, 5, 10 and 20 min.)
Case Size: 21⁄2˝ >0 <2 X.0000
Case Material: Noryl® >=2 <20 XX.000 Backlite (optional): Manually turns backlite on and off
Wetted Parts: 17-4 PH stainless steel sensor; 316 >=20 <200 XXX.00 (four programmable auto on/off
stainless steel socket >=200 <2000 XXXX.0 options)
Socket Size: 1
⁄4 NPT >=2000 <19,999 XXXXX Maximum
Character Height: 0.5˝ (Peak Hold): Displays max. value when activated
Connection: Lower
Backlight: OFF by default Zero/Clear: Zeros display or clears max. value
Ranges: Vac. thru 19,999 psi (see standard when activated
ranges for other units of measurement) Battery: Four-level battery indication
Engineering Units: psi, in.Hg, cmHg, mmHg, kPa, MPa,
Battery: Two AAA alkaline batteries; approxi- bar, kg/cm2, ftH2O
mately 1000 hours battery life
Field Calibration: Zero and span
Overpressure: Vac. 0/3000-
0/1000 0/5000 0/19,999 STANDARD RANGES
Proof: 200% 150% 120% Vacuum
Burst: 800% 300% 150% in.Hg kPa cmHg Bar kg/cm2 mmHg
Cycle Life: 10 cycles 20/80% F.S. with negli-
8
–30/0 –100/0 –76/0 –1/0 –1/0 –760/0
gible performance loss Compound
Vibration: Less than ±0.1% F.S. effect for in.Hg/psi kPa mPa Bar kg/cm2 ft H2O
0/2000 Hz at 20 g’s in any axis –30/300 –100/2000 – –1/20 –1/20 –35/700
–30/600 –100/4000 – –1/20 –1/20 –35/140
Shock: Less than ±0.05% F.S. effect for 100
–30/100 –100/7000 – –1/20 –1/20 –35/230
g’s, 20msec shock in any axis
–30/150 –100/1050 – –1/11 –1/11 –35/350
Operating Temp.: –10°C to 60°C –30/300 –100/2100 – –1/21 –1/21 –35/700
(14°F to 140°F) Pressure
Storage Temp.: –20°C to 70°C psi kPa mPa Bar kg/cm2 ft H2O
(-4°F to 158°F) 0/30000 0/2000 – 0/200 0/200 0/700
(maximum temperature shift is 0/60000 0/4000 – 0/400 0/400 0/140
.028% per °F from –20°F to 180°F 0/10000 0/7000 – 0/700 0/700 0/230
starting at 68°F. For vacuum and 30 psi 0/20000 0/1400 – 0/140 0/140 0/460
ranges the maximum temperature 0/30000 0/2100 – 0/210 0/210 0/700
shift is .04%) 0/50000 0/3500 – 0/350 0/350 –
0/10000 0/7000 – 0/700 0/700 –
Update Rate: 100ms
0/15000 – 0/100 0/105 0/105 –
Agency Approvals: CE EN 61326 (1998); CE EN 61326 0/20000 – 0/140 0/140 0/140 –
Annex A (heavy industrial) 0/30000 – 0/210 0/210 0/210 –
Packaging: Individual carton 0/50000 – 0/350 0/350 0/350 –
Opt’l. Features: ±0.25% of span accuracy; backlite; 0/10,000 – 0/700 0/700 0/700 –
0/15,000 – 0/100 0/1000 0/1000 –
3, 9, 12 o’clock connections; Alter-
0/19,999 – 0/140 0/1400 0/1400 –
nate socket configurations – upon
application; Customized keypad;
Protective boot; Bulk packaging TO ORDER THIS TYPE D1005PS GAUGE:
DISPLAY Select: 25 D1005PS 02L 100#
Type: LCD 1. Dial Size: 21⁄2˝
Display Digits: 1
/2 2. Case Type Number: D1005PS
3. Wetted Parts: Stainless Steel
4. Connection: 1⁄4 NPT lower
5. Range: 0/100 psi